Instructions
Professional Gas Cooktops 48" Natural Gas Models ZGU48N4G ZGU48N6R ZGU48N6D
48" LP Gas Models ZGU48L4G ZGU48L6R ZGU48L6D
36" Natural Gas Models ZGU36N6 ZGU36N4R ZGU36N4D
36" LP Gas Models ZGU36L6 ZGU36L4R ZGU36L4D

Before you begin—Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Owner’s Manual for future reference. This appliance must be properly grounded. See “Electrical Supply”, page 6. CAUTION WARNING
For Monogram local service in your area, 1-800-444-1845. For Monogram Service in Canada, Call 1-888-880-3030. For Monogram Parts and Accessories, call 1-800-626-2002.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the GE Appliance Warranty. See the Owner’s Manual for details.
If you received a damaged cooktop, you should contact your dealer.
In the Commonwealth of Massachusetts:
Island installations: Check local building codes for the proper method of cooktop installation. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the cooktop should be installed in accordance with the National Fuel Gas Code ANSI 223.1-1990 and National Electrical Code ANSI/NFPA 70-1990.
Standard countertop and island installations: A 1200 CFM Hood is recommended for 48" cooktops. A 600 CFM hood is recommended for 36" cooktops. Hoods should be 24" min. deep and the same width as the cooktop.
Contents Design Information Models Available 3 Accessory Requirements 3 Product Dimensions and Clearances 4 Installation Options 5 Advance Planning 5
Installation Step 1: Remove Packaging 7 Step 2: Cut the Countertop Opening 7 Step 3: Install the Cooktop 8 Step 4: Conect Cooktop to Gas 8 Step 5: Install the Cooktop Backguard 8 Step 6: Connect Electrical 9 Step 7: Assemble Burners, Check Ignition 9 Adjustable Low Burner Settings 10 Finalize Installation 10
Installation Preparation Tools & Materials Required 6 Power Supply Locations 6

Models Available
These cooktops are factory set for either natural gas or liquid propane gas. Order the model for your installation situation.
ZGU48N6R 6 gas burners and grill
ZGU36N4R 4 gas burners and grill
ZGU48N6D 6 gas burners and griddle
ZGU36N6 6 gas burners
ZGU48L6R 6 gas burners and grill
ZGU36L4R 4 gas burners and grill
ZGU48L6D 6 gas burners and griddle
ZGU36L6 6 gas burners
All models require the installation of a backguard or trim. A backguard/trim should be ordered at the same time as the cooktop. Both should be on site at the time of installation.
22" High Backguard With Warming Shelf
48" backguards, order one: ZXC1B48 1/2" trim backguard (required for island installations or installations where back wall is non-combustible; such as brick, ceramic tile, marble, etc).
ZXC12B48 12" high backguard
ZXC22B48 22" high backguard with warming shelf (2 piece)
36" backguards, order one: ZXC1B36 1/2" trim backguard (required for island installations or installations where back wall is non-combustible; such as brick, ceramic tile, marble, etc).
ZXC12B36 12" high backguard
ZXC22B36 22" high backguard with warming shelf (2 piece)
Installation Note: For approved installations to non-combustible back wall materials, consult material representative to ensure that the material has appropriate resistance to staining and/or discoloration.
12" High Backguard · 1/2" Trim


Installation Instructions 18" Min. 12" Min. to Combustible Material Each Side
Installation Instructions 18" Min. 12" Min. to Combustible Material Each Side
12" Min. to Combustibles Without Backguard or 0" to Non-Combustible Wall with 1/2" Trim

Installation Options
1/2" Above Adjacent Countertops.
Front Projects Outward as Shown From Standard Depth Cabinets.
1/2" Above Adjacent Countertops.
3" to Center Line of Gas Inlet
Flush With Cabinet Front
Cabinet Face - Projecting Control Panel
Front Flush With Cabinets - a Minimum of 25-3/4" Cabinet Depth Required
Cabinet Face - Flush Control Panel
combustible materials. –Allow 36" min. above the cooking surface to
the cooktop. –For 48" models, we recommend the vent
combustible materials.
hood blower be 1200 CFM. –For 36" models, we recommend the vent
A.G.A. approved.

Tools & Materials Required:
fittings. Note: Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE LINE.
7" for 36" Models 17" for 48" Models
Gas Line to Cooktop
Locate Gas Supply 2" Maximum Protrusion From Wall or on Floor 2" From Wall
Electric Supply: These cooktops must be supplied with 120 volt, 60 Hz., and connected to a individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time delay fuse.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of shock hazard from this appliance.
Receptacle Box Cover Plate
If the electrical service provided does not meet the above specifications, it is recom- mended that a licensed electrician install an approved outlet.
DO NOT UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

Use a hand-truck to move this cooktop.

48" wide models are designed to fit in 48" or wider base cabinets 36" wide models are designed to fit in 36" or wider base cabinets

cut a 5" x 5" square in the left rear corner for the gas inlet and power cord clearances.

Alternate Bracket Screw Holes
A manual shut-off valve must be installed where it will be accessible.
Flex or Rigid Gas Line To Regulator
connections in the system.

Plug power cord into properly grounded receptacle.
Main Burner Venturi (rear)
Simmer Burner Venturi (rear)
Simmer Burner Venturi (front) Main Burner Venturi (front)
insufficient air flow, adjust the shutter counterclockwise to increase air inlet. –If the flame is noisy or tends to lift away from the burner, there is too much air. Turn the shutter clockwise to reduce air.

Adjustable low setting The open top burners and grill valves have an adjustable low setting. Each valve is individu- ally tested and adjusted before it is shipped. Minor adjustments may be required due to fluctuations in local gas pressure. Adjustments to increase or decrease gas flow may be necessary.
Place the burner grates into operating position. Press corner of the grate to the cooktop. The grates should be seated and should not rock.
The grill and griddle are secured with screws at the front. They are designed to be stationary and should not to be removed.
The griddle has two leveling screws beneath the rear flue cover which can be used to adjust to the desired slope. The center screw is for shipping purposes only and should be removed.
(continued)


® local service in your area, call 1-800-444-1845.
Monogram. We bring good things to life.
GE Consumer Products General Electric Company Louisville, KY 40225 © 2003 General Electric Company
Pub. No. 49-8812-6 Dwg. No. 164D3333P056
10659 - Rev. 6
®
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.