GE Monogram ZGU486LDPSS
Table of Contents 2 sections Product Dimensions and Clearance · Side View with a Backsplash ShowHide
Page 1 of the GE Monogram ZGU486LDPSS user manual — Product Dimensions and Clearance
Page 1 · click to enlarge
Page 1

ZGU486NDPSS (Natural Gas) ZGU486LDPSS (Liquid Propane) GE Monogram® 48" Professional Gas Rangetop with 6 Burners and Griddle

Dimensions and Installation Information

Professional rangetops offer a number of choices in size and rangetop configurations.

* The opening between a 4" high backsplash must be 36" to allow the rangetop to slide back against the wall.

Product Dimensions and Clearance

WARNING: Installations without a hood require 48" mini- mum to combustibles above the rangetop. A custom hood installation with exposed horizontal combustible surfaces must have an "auto-on" feature. Refer to hood installation instructions for specific hood clearances. The surface of the entire back wall above the countertop and below the hood must be covered with a non-combustible material such as metal, ceramic tile, brick, marble or other stone.

A 48"- or 54"-wide professional vent hood with a minimum 1200 CFM is recommended for installation over this rangetop.

Clearances between rangetop and side wall or combustible material must be at least 12" on each side.

GE Monogram ZGU486LDPSS — Product Dimensions and Clearance diagram (page 1)
Fig. 1 · Product Dimensions and Clearance

Allow 8" free space below the top surface of countertop. Allow additional clearances below the burner box to install the regulator and make house gas supply connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabinetry. Controll panel projects forward from standard depth cabinets.

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Front of deep cabinets can align with control panel beveled edge.

130453 Specification Created 7/08

Page 2 of the GE Monogram ZGU486LDPSS user manual — Side View with a Backsplash
Page 2 · click to enlarge
Page 2

ZGU486NDPSS (Natural Gas) ZGU486LDPSS (Liquid Propane) GE Monogram® 48" Professional Gas Rangetop with 6 Burners and Griddle

Dimensions and Installation Information

Backsplash Accessories The rangetop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used. ZX12B48PSS, 12" backsplash ZXADJB48PSS, 30"-36" adjustable-height backsplash with warming shelf

Advance Planning for 48" Professional Rangetops Professional rangetops offer a number of choices in size and rangetop configurations. • All Professional rangetops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation. Note: Conversion kits are included with the rangetop if the wrong gas type was ordered. High Altitude kit, WB28K10553, is also available. The kits must be installed by a qualified service technician at additional cost.

Side View with a Backsplash

GE Monogram ZGU486LDPSS — Side View with a Backsplash diagram (page 2)
Fig. 2 · Side View with a Backsplash
GE Monogram ZGU486LDPSS — Side View with a Backsplash diagram (page 2)
Fig. 3 · Side View with a Backsplash

Electrical Requirements Rangetops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse.

  • Gas Supply
  • Natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7” and 13” water column.
  • The liquid propane models are designed to operate at 10" water column pressure. For proper operation, the pressure of the LP source to the regulator must be between 11” and 13” water column.

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

130453 Specification Created 7/08

Page 3 of the GE Monogram ZGU486LDPSS user manual — Side View with a Backsplash
Page 3 · click to enlarge
Page 3

ZGU486NDPSS (Natural Gas) ZGU486LDPSS (Liquid Propane) GE Monogram® 48" Professional Gas Rangetop with 6 Burners and Griddle

  • Features and Benefits
  • Authentic Professional appearance with premium-grade, 304 stainless steel with smoothly finished edges and large electronic control knobs
  • Sealed, dual-flame stacked burners deliver a full spectrum of heat settings, from an ultra-low 140˚F simmer to an intense 18,000 BTUs
  • Stainless steel and aluminum-clad griddle offers 18,000 BTUs* of cooking power, allowing fast and consistent heating across the entire cooking surface
  • Electronic ignition with automatic reignition ensures a continuous flame and reignites automatically if accidentally extinguished
  • Reversible burner grates are flat on one side and uniquely contoured on the other to accommodate round-bottom woks
  • Stainless steel griddle cover included with the rangetop
  • A bamboo cutting board is included
  • Optional fixed (12") or adjustable-height (30"-36") backsplashes are available
  • Optional black knob kit is available
  • Model ZGU486NDPSS – Natural gas, 6 burners and griddle
  • Model ZGU486LDPSS – Liquid propane, 6 burners and griddle
GE Monogram ZGU486LDPSS — Side View with a Backsplash diagram (page 3)
Fig. 4 · Side View with a Backsplash

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

130453 Specification Created 7/08

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE Monogram ZGU486LDPSS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE Monogram ZGU486LDPSS

Be the first to ask — other owners or our team will answer.

Original document

GE Monogram ZGU486LDPSS manual PDF

3 pages·646 KB·Range·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…