Read these instructions completely and carefully.
Be sure the installation of this product in a mobile home conforms with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. If this standard does not apply, you must follow the standard for Manufactured Home Installations, ANSI A225.1 and Manufactured Home Installations, Sites and Communities, ANSI/NFPA 501A or with local codes. You can get a copy of the Federal Standard by Writing:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance!
Office of Mobile Home Standards
HUD Building 451 7th Street, S.W. Washington, D.C. 24010
Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This appliance must be supplied with the proper voltage and frequency and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on the rating plate. We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician. After installation, have the electrician show you where your main cooktop disconnect is located. Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop according to governing codes could
result in a hazardous condition. If there are no codes, your cooktop must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70—Latest Edition. You can get a copy by writing:
National Fire Protection Association
Batterymarch Park Quincy, MA 02269 In Canada, your cooktop must be wired and fused to meet the requirements of the Canadian Electrical Code.
Installation Preparation Models Available 4 Parts Included 4 Materials You May Need 4 Tools You Will Need 4 Advance Planning and Installation Options 5 Pre-Installation Checklist 6 Dimensions and Clearances 7 Gas Supply Locations 8
Installation Instructions for Natural to LP Gas Conversion Tools You Will Need 15 Adjusting the Regulator 15 Changing the Orifices 15, 16 Adjusting Burner Flames 16
Installation Instructions for LP to Natural Gas Conversion Tools You Will Need 17 Adjusting the Regulator 17 Changing the Orifices 17, 18 Adjusting Burner Flames 18
Installation Instructions Step-by-Step Instructions 9–11 Operation Checklist 11
Installation Options Installation With a Downdraft Vent 12 Installation Over a Warming Drawer 13 Installation Over a Single Oven 14


These models are factory set for either natural gas or LP gas operation. Be sure to order the correct model for the installation situation.
CSA-Approved Flexible Gas Line 1/2″ Min. ID, 1/2″ NPT Connection, 3-foot Maximum Length (Massachusetts Only) NOTE: Purchase new line, do not use

INSTALLATION OPTIONS
Cooktop and ZVB36 Downdraft Vent Combination Installation
These cooktops may be installed with a 36″ Monogram Downdraft Vent, model ZVB36. See page 12 for cutout and clearances.
– The countertop must have a deep flat surface to
accommodate the combined installation of the cooktop and vent.
– Use cabinets no more than 13″ deep.
– The downdraft vent with blower, motor and
– Maintain 30″ minimum clearance between
ductwork will occupy the base cabinet.
cooktop and unprotected cabinets directly above cooktop.
– Consideration must be given to electrical and gas
supply locations. See page 8.
– If clearance is less than 30″, protect cabinet
bottoms with flame-retardant millboard at least 1/4″ thick, or gypsum board at least 3/16″ thick, covered with 28 gauge sheet steel or .02″ thick copper.
Cooktop and ZTD910 or ZKD910 Warming Drawer Combination Installation
These cooktops may be installed over a Monogram 30″ or 27″ Warming Drawer, model ZTD910 or ZKD910. See page 13 for cutout and clearances.
– Clearance between cooktop and protected
cabinetry must not be less than 24″.
– Consideration must be given to electrical and gas
– An exhaust hood that projects at least 5″
supply locations. See page 8.
beyond front of cabinets can reduce risk of burns caused by reaching over heated surface units.
Cooktop and ZET1 or ZET938 Single Oven Combination Installation
These cooktops may be installed over a Monogram 30″ Oven, model ZET1 or ZET938. See page 14 for cutout and clearances.
– Working areas adjacent to the cooktop
should have 18″ minimum clearance between countertop and cabinet bottom.
– Consideration must be given to electrical and gas
supply locations. See page 8.
Installation Above Cabinet Drawers
WB28T10185 High Altitude Kit For operation above 5,000 feet, order WB28T10185 Conversion Kit. This kit includes orifices for both LP and Natural gas operation.

Be sure to place all literature, Owner’s Manual, Installations, etc. in a safe place for future reference.
Left and right side
Foam packaging Regulator taped to the underside
Foam support · grate boxes · Center grate box


3-3/8″ min. from cutout to rear vertical combustibles
2-1/2″ min. from cutout to front of countertop

Install a manual shut-off valve in the gas line in an easily accessible location outside the cooktop. Be sure you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12″ below the countertop.
Electrical supply:
This cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120 volt, 60 Hz power supply. A separate circuit, protected by a 15 amp time delay fuse or circuit breaker, is required.
Optional Combination Installations This cooktop may be installed in combination with a ZVB36 Monogram Downdraft Vent, a ZET1 or ZET938 Single Oven or a ZTD910 Warming Drawer. • The gas and electrical supply must be located where it will not interfere with vent housing, the oven or the warming drawer. Review pages 12 to 14 for additional installation requirements.
The gas inlet is located on the bottom of the burner box at the rear and center.
Do Not, Under Any Circumstances, Cut Or Remove The Third (Ground) Prong From The Power Cord.
Do not use an extension cord.
1” min.


A. Remove the screws on the sides of the cooktop
burner box. Use those screws to attach the side mounting brackets.
opening. Make sure the front edge of the countertop is parallel to the cooktop.
OPTION: You can install a 90º elbow (not supplied) onto the gas inlet and route the gas connections to avoid interference when installed over an oven, with a downdraft vent, a warming drawer or other cabinetry features.
Secure the hold-down bracket to the cabinet sides with screws.
B. Complete the connection between the regulator
and the shut-off valve.
C. Before testing for leaks, make sure all burner
knobs are in the OFF position.

After connecting the cooktop to gas, check system for leaks with a manometer. If a manometer is not available, turn the gas supply on to the cooktop and use a liquid leak detector at all joints and connections to check for leaks. Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.
INSTALL PRESSURE REGULATOR WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance.
WARNING: Do not use a flame to check for leaks. Disconnect the cooktop and its individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa). Isolate the cooktop from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
To reduce the possibility of gas leaks, apply teflon tape or a thread compound approved for use with LP or Natural gases to all threaded connections.
bottom pipe connection. Make sure the top of the regulator is facing toward the cabinet front, and the arrow on the back of the regulator points to the cooktop.

Burner Box · 90º Elbow


The electrode of the electronic ignition system is positioned above the surface of the burner base. Do not remove a burner cap or touch the electrode of a burner while another is turned on. Damage or electrical shock may occur.
D. Check igniters.
Operation of the electric igniters should be tested after the cooktop and supply line have been carefully checked for leaks and the cooktop has been connected to the electrical power.
the position of one larger burner base, head and cap. The large and regular size pieces are not interchangeable.
Make sure the hole in the burner head is properly aligned with the electrode in the burner base.
– The burner should light when gas is available
to the burner.
– Once the burner lights, it should be turned to
another position.
E. Burner ignition.
Cooktop Spark Ignition—When you turn the cooktop knob to LITE, the spark igniter makes a series of electric sparks (ticking sounds) which light the burner. During a power failure, the burners will not light automatically. In an emergency, a cooktop burner may be lit with a match by following the steps below.
C. Place the burner caps on the burner heads.
Make sure that the burner caps are properly seated on the burner heads.


F. Turn on each burner. On LP models, flames
should be blue in color but may have yellow tips. Natural gas models should have soft, blue flames. The burner flames should not flutter or blow away from the burner. The flame should be no less than 1/4″ on the lowest setting and no greater than 1-1/2″ on highest setting.
Cooktop burner 1/4″ to 1-1/2″
Burners should be checked frequently
G. The three cooktop grates are designed for
specific positions. For maximum stability, these grates should only be used in their proper positions: they should not be interchanged. Position the two side grates with locking rails toward the center grate so that a continuous “arc” is formed with the center ribs of all three grates. Make sure the center grate is locked into position over the rails on the side grates and that all the grates are stable and level.
“OUTSIDE”
“OUTSIDE”
edges · edge · edge

COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to accommodate the cooktop and vent. Countertops with a rolled front edge and backsplash will not provide the flat surface area required.
The installation of the downdraft vent with this cooktop requires careful consideration. Both the cooktop and the vent must be installed according to each specific installation instruction.
– All cutout clearances for this installation must be
observed.
3/8″ 36-3/4″ 3/8″
3-3/8″ min. cooktop cutout to rear vertical combustible surface
23-5/16″ total flat
34″ cooktop and vent area cutout
7/16″ cooktop overlap (1-1/4″ at center)
Front edge of countertop
12″ min. cutout to wall, both sides 2-1/2″ min. clearance to cutout
POWER SUPPLY
The combined installation will fit in a standard 24″ deep base cabinet. Use a 36″ or wider base cabinet.
If local codes permit, the vent and cooktop may operate from the same 120V, 15 amp duplex outlet. Locate the gas and electrical supply as shown on page 8.
– The vent housing, blower and ductwork will
occupy the base cabinet.

POWER SUPPLY:
If local codes permit, the cooktop and warming drawer may operate from the same 120V duplex outlet. Refer to installation instructions for details.
These cooktops may be installed over a 30″ or 27″ Warming Drawer. Both the cooktop and the warming drawer must be installed according to each specific installation instruction.
Install 2x4 or 2x2 anti-tip block against
rear cabinet wall 9″ from cutout floor
1-1/2″ cabinet top
to bottom of block
19-1/8″ 2-1/2″ min.
5-1/2″ min.
height 9-1/4″ A
Dim. A ZTD910 28-1/2″ ZKD910 25-1/2″
23-1/2″ min.
Use a 36″ or wider base cabinet.

COOKTOP INSTALLATION OVER A 30″ MONOGRAM SINGLE OVEN, MODEL ZET1 OR ZET938
The oven requires a separate, properly grounded 20 Amp, 3-wire 208 or 240 volt, 60 Hz power supply. The cooktop requires a separate 120V power supply. See page 8. Where codes permit, the gas shut-off valve may be located in an adjacent cabinet or other easily accessible location.
These cooktops may be installed over the Monogram ZET1 or ZET938 single oven. Both the cooktop and the oven must be installed according to each specific installation instruction.
– Allow 4″ Min. clearance from the top of the
countertop to the top of the oven cutout.
1-1/2″ cabinet top
19-1/8″ 2-1/2″ min.
4″ min. 36″ countertop
height 27-1/4″ min. 27-5/16″ max. 28-1/2″ min. 28-5/8″ max.
23-1/2″ min.
Use two 2x4’s or equivalent runners spaced 25″ centerline
to centerline in the opening and flush with top of toekick. Or elevate the oven floor to desired height. The support must
be level, rigidly mounted and capable of supporting 200 lbs.
Use a 36″ or wider base cabinet.

ADJUST THE REGULATOR
A. Disconnect all electrical power, at the main circuit
breaker or fuse box. B. Shut off the gas supply to the cooktop by closing the
manual shut-off valve. C. Adjust the pressure regulator by the following
The pressure regulator and burner orifices are set for natural gas operation.
To convert this cooktop from natural gas operation to LP operation, the regulator and burner orifices must be converted. LP burner orifices are attached to the regulator.
NAT
NAT
LP
NAT
NAT
LP
L.P./propane position NAT. position
DOWN
INSTALLATION TIP: First remove all orifices and then start replacing them. This will help to prevent the possibility that some may not be replaced. A. Remove the burner grates,
burner caps and burner heads. B. Using a 7mm nut driver, remove the
top burner orifices. There are two orifices per burner. The main orifice is located low in the center of the burner, while the simmer orifice is located higher beside the center of the burner.
Crescent wrench 7mm nutdriver
screwdriver (2 to 2.4 mm or
3/32″ tip size, 60 mm long)


A. Turn all burners on highest setting and check the flames.
They should be blue in color and may have some yellow tipping at the ends of the flame when using LP gas. Foreign particles in the gas line may cause an orange flame at first, but this will soon disappear. B. Turn the cooktop burner knob to “LO” while observing
The 34SL and 51SN are for all five burners.
the flame. Adjust the setting of the upper row of flames using the valve bypass screw as follows: Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on. C. To adjust the flame, remove the knobs. Insert a
screwdriver through the access hole in valve shaft as shown.
flame appearance is correct. E. Testing Flame Stability:
Test 1 – Turn the knob from “HI” to “LO” quickly.
If the upper row of flames goes out at this setting, increase the flame size and test again. Test 2 – With the burner on “LO”, open and close the
cabinet door under the cooktop. If the flame is extinguished by the air currents created by the door movement, increase the flame height and test again. NOTE: When the burner is on the “SIM” setting, the upper row of flames will go out. F. Flame Recheck:
C. Install the proper orifices in the exact locations as noted
in the illustrations above. D. Return the natural gas orifices to the bracket and
reattach the bracket and the instruction sheet to the pressure regulator using the screw removed previously. E. Replace the burner bases, heads, caps and top grates.
After the adjustment is made, turn all burners off. Ignite each burner individually. Observe the flame at the “HI” position. Rotate the knob to the lowest setting and be sure that the flame size decreases as the knob is rotated counterclockwise. Once the conversion is complete and checked ok, fill out the conversion sticker and include your name, organization and date conversion was made. Apply the sticker near the cooktop gas inlet opening to alert others in the future that this appliance has been converted. If converting back to the original gas, please remove the sticker so others know the appliance is set to use its original gas.

ADJUST THE REGULATOR
A. Disconnect all electrical power, at the main circuit
breaker or fuse box. B. Shut off the gas supply to the cooktop by closing the
manual shut-off valve. C. Adjust the pressure regulator by the following
The pressure regulator and burner orifices are set for LP gas operation.
To convert this cooktop from LP gas operation to natural gas operation, the regulator and burner orifices must be converted. Natural gas burner orifices are attached to the regulator.
NAT
NAT
LP
NAT
NAT
LP
L.P./propane position NAT. position
DOWN
INSTALLATION TIP: First remove all orifices and then start replacing them. This will help to prevent the possibility that some may not be replaced. A. Remove the burner grates,
burner caps and burner heads. B. Using a 7mm nut driver, remove the
top burner orifices. There are two orifices per burner. The main orifice is located low in the center of the burner, while the simmer orifice is located higher beside the center of the burner.
Crescent wrench 7mm nutdriver
screwdriver (2 to 2.4 mm or
3/32″ tip size, 60 mm long)


A. Turn all burners on highest setting and check the flames.
They should be blue (no yellow tipping) when using natural gas. Foreign particles in the gas line may cause an orange flame at first, but this will soon disappear. B. Turn the cooktop burner knob to “LO” while observing
The 34SL and 51SN are for all five burners.
the flame. Adjust the setting of the upper row of flames using the valve bypass screw as follows: Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on. C. To adjust the flame, remove the knobs. Insert a
screwdriver through the access hole in valve shaft as shown.
flame appearance is correct. E. Testing Flame Stability:
Test 1 – Turn the knob from “HI” to “LO” quickly.
If the upper row of flames goes out at this setting, increase the flame size and test again. Test 2 – With the burner on “LO”, open and close the
cabinet door under the cooktop. If the flame is extinguished by the air currents created by the door movement, increase the flame height and test again. NOTE: When the burner is on the “SIM” setting, the upper row of flames will go out. F. Flame Recheck:
C. Install the proper orifices in the exact locations as noted
in the illustrations above. D. Return the LP gas orifices to the bracket and reattach
After the adjustment is made, turn all burners off. Ignite each burner individually. Observe the flame at the “HI” position. Rotate the knob to the lowest setting and be sure that the flame size decreases as the knob is rotated counterclockwise. Once the conversion is complete and checked ok, fill out the conversion sticker and include your name, organization and date conversion was made. Apply the sticker near the cooktop gas inlet opening to alert others in the future that this appliance has been converted. If converting back to the original gas, please remove the sticker so others know the appliance is set to use its original gas.
the bracket and the instruction sheet to the pressure regulator using the screw removed previously. E. Replace the burner bases, heads, caps and top grates.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.