If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com
LP Gas Model ZGU375LS
Monogram.
®



ZGU375NS 36" natural gas cooktop ZGU375LS 36" LP gas cooktop
For those who prefer gas heat for cooking, the Monogram built-in gas stainless steel cooktop offers the cooking method of choice.
These models are factory set for either natural gas or LP gas operation. Be sure to order the correct model for the installation situation.

2-15/16" Min. From Cooktop to Vertical Combustible Surface When Installed
11" Min. to Wall From Cooktop Edge When Installed Both Sides
* If a countertop backsplash is used, it must be constructed of non-combustible materials (such as masonry, ceramic, granite, stainless steel, etc.) whenever the cutout to rear vertical surface is less than 3-3/8".
–Clearance between cooktop and protected
cabinetry must not be less than 24". –An exhaust hood that projects at least 5"
beyond front of cabinets can reduce risk of burns caused by reaching over heated surface units. –Working areas adjacent to the cooktop
cooktop and unprotected cabinets directly above cooktop. –If clearance is less than 30", protect cabinet
bottoms with flame-retardant millboard at least 1/4" thick, or gysum board at least 3/16" thick, covered with 28 gauge sheet steel or .02" thick copper.

Advance planning installation options
Cooktop and ZVB36 Downdraft Vent Combination Installation. See page 9. These cooktops may be installed with a 36" Monogram Downdraft Vent, models ZVB36. See page 9 for cutout and clearances. –The countertop must have a deep flat
Cooktop and ZTD910 Warming Drawer Combination Installation. See page 10. These cooktops may be installed over a Monogram 30" Warming Drawer, models ZTD910. See page 10 for cutout and clearances. –Consideration must be given to electrical and
surface to accommodate the combined installation of the cooktop and vent. –The downdraft vent with blower, motor and
gas supply locations. See page 6. –Read the Warming Drawer Installation
Instructions packed with the product, or to review ahead of time, order Pub. No. 49-8937.
ductwork will occupy the base cabinet. –Consideration must be given to electrical
and gas supply locations. See page 6. –Read the Downdraft Vent Installation
Cooktop and ZET837 Single Oven Combination Installation. See page 11. These cooktops may be installed over a Monogram 30" Oven, model ZET1038. See page 11 for cutout and clearances. –Consideration must be given to electrical and
Instructions packed with the product, or to review ahead of time, order Pub. No. 49-80185.
gas supply locations. See page 6. –Read the 30" Oven Installation Instructions
packed with the product, or to review ahead of time, order Pub. No. 49-80188.
codes, use solid pipe with fittings.

Cut the Opening
11-9/16" Min. Cutout To Side Wall
11-9/16" Min. to Side Wall
3-3/8" Min. to Rear Vertical Combustibles
2-3/4" Min. From Front of Countertop
42" Wide Cabinet Base Recommended
Optional Combination Installations. This cooktop may be installed in combination with a ZVB36 Monogram Downdraft Vent, with a ZTD910 Warming Drawer, or a ZET1038 single wall oven. See “Optional Installations”, pages 9 through 11, for cutout and clearances of these installations.
back of cutout and vertical combustible wall. –Allow at least 11-9/16" clearance from right
and left side of cutout to adjacent wall. –Allow at least 2-3/4" clearance between
front of cutout and front edge of countertop.
35-5/16" · 18-7/8"

Power supply locations
For ease of installation, and if local codes permit, the gas supply line into the cooktop should be 1/2" or 3/4" ID flexible metal appliance connector, three to five feet long. NOTE: Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE LINE. •Make gas connection through rear wall, or on cabinet floor at rear, as illustrated.
Electrical supply: This cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120 volt, 60 Hz power supply. A separate circuit, protected by a 15 amp time delay fuse or circuit breaker, is required.
Optional Combination Installations This cooktop may be installed in combina- tion with a ZVB36 Monogram Downdraft Vent, a ZET1038 Single Oven or a ZTD910 Warming Drawer. • The gas and electrical supply must be located where it will not interfere with vent housing, the oven or the warming drawer. See pages 9 through 11 for alternate installation requirements.
16" 7" · 8" · 42"

right direction. See arrow on underside of regulator. •Install a manual shut-off valve in the gas line in an easily accessible location.
Solid Piping or Flexible Connector
Pipe Stub From House Gas Supply
required at each end of the flexible connector. •Turn on the gas. Check for leaks using a liquid leak detector at all joints in the system (the pressure test fitting is on the side of the regulator).
IMPORTANT: Disconnect the cooktop and the individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig. Isolate the cooktop from the gas supply piping system by closing the individual manual shut-off valve to the cooktop during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.

Do not use a flame to check for gas leaks.
IL NE FAUT PAS UTILISER DE FLAMME POUR VÉRIFIER S’IL Y A DES FUITES.

3 Connect electrical
HIGH position. –The igniter will spark and the burner will
light; the igniter will cease sparking when the burner is lit. –First test may require some time, while air is

flushed out of the gas line. –Turn knob to OFF. –Repeat the procedure for each burner.
To aid reassembly, each brass Burner Head is marked with a clock face. Replace the Burner Head with the arrow pointing to the rear of the cooktop (12 o’clock position).
Step

Cooktop Installation with a 36" Monogram Downdraft Vent, models ZVB36. The installation of the downdraft vent with this cooktop requires careful consideration. Both the cooktop and the vent must be installed according to each specific installa- tion instruction. For accurate planning, review the Downdraft Vent Installation Instructions in advance, order Pub. No. 49-80185.
Countertop Requirements: The countertop must have a deep flat surface to accommodate the cooktop and vent. Countertops with a rolled front edge and backsplash will not provide the flat surface area required. • Review the illustration to determine the countertop surface requirements. –All cutout clearances for this installation
must be observed.
36-1/2" 9/16" 3-3/8" Min. Cooktop Cutout to Rear Vertical Combustible Surface
9/16" 34" Vent Cutout 1/4" Overlap
35-5/16" Cooktop Area Cutout
Surface Required at Center
7/16" Cooktop Overlap (1-1/4" at Center)
Front Edge of Countertop
11-9/16" Min. Cutout to Wall, Both Sides
2-3/4" Min. Clearance to Cutout
Base Cabinet Requirements: The combined installation will fit in a stan- dard 24" deep base cabinet. A base cabinet at least 42" wide is recommended. –The vent housing, blower and ductwork will
Power Supply: If local codes permit, the vent and cooktop may operate from the same 120V, 15 amp duplex outlet. Locate the gas and electrical supply as shown on page 6.
occupy the base cabinet.
Ductwork: Ductwork should be planned in advance. •The blower system is designed for use with 3-1/4" x 10" ductwork. It can be transitioned to 6" round. –The ductwork MUST be vented to the
outside. –The duct run should not exceed 150 ft. or
equivalent length when bends or various fittings are used. Again, refer to Downdraft Vent Installation Instructions for details.

Cooktop Installation Over a 30" Monogram Warming Drawer, models ZTD910. These cooktops may be installed over a 30" Warming Drawer. Both the cooktop and the warming drawer must be installed according to each specific installation instruction. For accurate planning, review the Warming Drawer Installation Instructions in advance, order Pub. No. 49-8937.
–Allow 2" clearance between the cooktop
bottom and the top of the cutout, or 7-1/2" from the top of the countertop as illustrated.
Power Supply: If local codes permit, the cooktop and warm- ing drawer may operate from the same 120V duplex outlet. See page 6.
Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9" From Cutout Floor to Bottom of Block
Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9" From Floor to Bottom of Block
2x4 or 2x2 Runners or Solid Bottom, 25" on Center

Installation Options
Cooktop Installation Over a 30" Monogram Single Oven, models ZET1038. These cooktops may be installed over the Monogram ZET1038 single oven. Both the cooktop and the oven must be installed according to each specific installation instruc- tion. For accurate planning, review the 30" Oven Installation Instructions in advance, order Pub. No. 49-80188. –Allow 6" Min. clearance from the top of the
Power Supply: The oven requires a separate, properly grounded 30 Amp, 3-wire 120/208 or 120/240 volt, 60 Hz power supply. The cook- top requires a separate 120V power supply. See page 6. Where codes permit, the gas shut- off valve may be located in an adjacent cabinet or other easily accessible location.
countertop to the top of the oven cutout.
28" Min. 28-3/8" Max.
23" Max.
Use two 2x4's or equivalent runners spaced 25" centerline to centerline in the opening & flush with top of toekick.Or, elevate the oven floor to desired height.The support must be level, rigidly mounted and capable of supporting 200lbs.

Pub. No. 49-80218-1 Dwg. No. 164D4290P370
11173-E
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.