Dimensions and Installation Information (in inches)

Locate Junction Box 22" Above Cutout Floor, Within 5" of Right Rear Wall
Installation Flexibility These ovens may be installed below a countertop and beneath approved cooktops. They may also be installed in combination with an Advantium oven and a warming drawer. They may also be installed side by side. This oven is not approved for stackable, one over another installations.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.


2 (5.1 cm) Min.
2 (5.1 cm) Min.
Side by Side Installations Install two wall ovens in separate cutouts. Allow 2" (5.1 cm) min. between cutouts.
The solid bottom or runners must be level with the bottom of the cutout, or the bottom trim may not install correctly and could interfere with the door opening. If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. The runners and braces must support 200 lbs. (90 kg).
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
Listed by Underwriters Laboratories
130189 Specification Created 4/07


Specification Created 4/07