EN
GE Monogram logo
Official user manual

GE Monogram JN327

16 pages·348 KB·Ventilation Hood·PDF·ENDEFRITNLJA
GE Monogram JN327
Table of Contents 11 sections Safety Information · Operating/Care and Cleaning Instructions · Charcoal Filter · Grease Filter · … ShowHide
Page 1 of the GE Monogram JN327 user manual — 49-80389-1 04-06 JR
Page 1 · click to enlarge
Page 1

ge.com

Range Hoods

Safety Information 2, 3

Owner’s Manual and Installation Instructions

Operating/Care and Cleaning Instructions Charcoal Filter 5 Grease Filter 4 Hood Light 5 Hood Surfaces 5 Controls 4

JN327–Recirculation only JV338*–Vent options only JV347*–Vent & Recirculation

options JV367*–Vent & Recirculation

Consumer Support Consumer Support . . .Back Cover Warranty 15

*

GE Monogram JN327 — * diagram (page 1)
Fig. 1

Write the model and serial numbers here:

You can find them on a label on the back wall of the hood.

49-80389-1 04-06 JR

options RN328–Recirculation only · Model # · Serial #

Page 2 of the GE Monogram JN327 user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. READ AND SAVE THESE INSTRUCTIONS
Page 2 · click to enlarge
Page 2

Operating Instructions Safety Instructions Consumer Support Installation Instructions

SAFETY PRECAUTIONS

WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high

A. Use this unit only in the manner intended

settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

by the manufacturer. If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off

B. Always turn hood ON when cooking on high

at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

C. Clean ventilating fans frequently. Grease should

not be allowed to accumulate on fan or filter.

D. Use proper pan size. Always use cookware

appropriate for the size of the surface element. WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

C. Do not use this unit with any solid-state speed

control device.

D. If using a cord connection kit, use only with range

hood cord-connection kit JXHC1 that has been investigated and found acceptable for use with this model range hood.

A. Installation work and electrical wiring must be

done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

E. This unit must be grounded. CAUTION – FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

B. Sufficient air is needed for proper combustion

and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

A. SMOTHER FLAMES with a close-fitting lid,

cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

C. When cutting or drilling into wall or ceiling, do

not damage electrical wiring and other hidden utilities.

B. NEVER PICK UP A FLAMING PAN—

D. Ducted fans must always be vented to the

You may be burned.

outdoors. WARNING – TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

C. DO NOT USE WATER, including wet

dishcloths or towels—a violent steam explosion will result.

I Do not attempt to repair or replace any part of

D. Use an extinguisher ONLY if:

1. You know you have a Class ABC extinguisher, and you already know how to operate it.

your hood unless it is specifically recommended in this guide. All other servicing should be referred to a qualified technician.

2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. READ AND SAVE THESE INSTRUCTIONS

Page 4 of the GE Monogram JN327 user manual — Reusable Metal Grease Filter—Ducted Installations Only
Page 4 · click to enlarge
Page 4

Using the hood controls.

Operating Instructions Safety Instructions Consumer Support Installation Instructions

Throughout this manual, features and appearance may vary from your model.

Control Knobs (on some models)

Switch Pad Controls (on some models)

ON

HI

OFF OFF

OFF

LO HI MED NITE

ON

OFF

LO

FAN Control Turn to HI, MED or LO as needed. Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.

LIGHT Control Press the pad at the top to turn the light ON.

FAN Control

Press the pad at the top to turn the fan on HI and at the bottom to turn it on LO. The center position is OFF. Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.

LIGHT Control

Turn to ON while cooking or to NITE for use as a night light.

Care and cleaning of the vent hood.

Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood.

Reusable Metal Grease Filter—Ducted Installations Only

The efficiency of your hood depends on a clean filter. Frequency of cleaning depends on hood use and the type of cooking you do. However, the grease filter should be cleaned at least once a month.

To clean: Soak and then agitate it in a hot water and detergent solution. Light brushing can be used to remove embedded dirt. Rinse, shake and let it dry before replacing.

To remove: Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back.

NEVER OPERATE THE HOOD WITHOUT THE FILTER IN PLACE. With careful handling, the metal filter will last for years. If a new replacement filter becomes necessary, order the part from your dealer. Order genuine GE part number WB02X8391.

To replace: Slip the back edge of the filter into the retaining tabs and push the front edge up until it snaps into place.

Grease filter

Page 5 of the GE Monogram JN327 user manual — Hood Light
Page 5 · click to enlarge
Page 5

Installation Instructions Consumer Support Safety Instructions Operating Instructions

Charcoal Filter—Recirculating Installations Only

The charcoal filter cannot be cleaned. It must be replaced. Order filter no. WB02X10700. Replacement filters can be ordered from your GE supplier. If the hood is not vented to the outside, the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors. The charcoal filter should be replaced after 6 to 12 months (depending on hood usage).

To remove: Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back. To replace: Slip the back edge of the filter into the retaining tabs and push the front edge up until it snaps into place.

Stainless Steel Surfaces (on some models)

Do not use a steel-wool pad; it will scratch the surface. To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the grain. Follow the cleaner instructions for cleaning the stainless steel surface.

To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:

National Parts Center 800.626.2002 ge.com

Painted Surfaces (on some models)

Do not use steel-wool pads or other abrasive cleaners. They will scratch the surface. Clean grease-laden surfaces of the hood frequently. To clean the hood surface, use a hot, damp cloth with a mild detergent suitable for painted surfaces. About one tablespoon of ammonia may be added to the water. Use a clean, hot, damp cloth to remove soap. Dry with a dry, clean cloth.

NOTE: When cleaning, take care not to come in contact with filters and other non-enameled surfaces. CAUTION: When cleaning the hood surfaces, be certain that you do not touch the light bulb with moist hands or cloth. A warm or hot light bulb may break if touched with a moist surface. Always let the light bulb cool completely before cleaning around it.

Hood Light

  • CAUTION: Let the light bulb cool completely before removing. A warm or hot bulb may break if touched with a moist cloth or hand. Remove the bulb and replace with an ordinary screw-base light bulb, not more than 60 watts . To remove the light cover (on some models) :
  • Press the sides with two fingers until the side prongs are released.
  • Lift the light cover and slide it toward you in one motion.
  • To replace the light cover:
  • Insert the prong located at the end of the cover into the top opening.
  • Gently push the cover up and press the sides to fit the side prongs into the side openings.
  • Release and the cover will lock in position.

Replaceable charcoal filter · Light cover

Page 6 of the GE Monogram JN327 user manual — OPTIONAL POWER CORD KIT JXHC1
Page 6 · click to enlarge
Page 6

Installation Range Hood Instructions

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

BEFORE YOU BEGIN

DUCTWORK REQUIREMENTS

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.

The venting system must exhaust to the outside.

  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical and electrical skills.
  • Completion time – 30 minutes–3 hours
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.

This hood can be vented vertically through upper cabinets or horizontally through an outside wall. Ductwork is not included. Exhaust connection: The hood exhaust has been designed to mate with standard 31⁄4″ x 10″ rectangular ducting or 7″ diameter round ducting. If a 6″ round duct is required, a rectangular-to-round transition adaptor must be used*. Do not use less than a 6″ diameter duct.

Maximum duct length: For satisfactory air movement, the total duct length of a 31⁄4″ x 10″ rectangular, 6″ or 7″ diameter round duct should not exceed 65 equivalent feet. See the WORKSHEET–CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH section.

FOR YOUR SAFETY:

Elbows, transitions, wall and roofcaps, etc., present additional resistance to airflow and are equivalent to a section of straight duct longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The charts on the following pages show you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of some typical ducts.

OPTIONAL POWER CORD KIT JXHC1

An optional Power Cord Connection Kit, model JXHC1, is available at extra cost from your GE supplier for installation using a standard 3-prong, grounded wall outlet. Follow the Installation Instructions packed with the kit to connect the power cord to the range hood.

* IMPORTANT: If a rectangular-to- round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper. Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any hood.

Page 7 of the GE Monogram JN327 user manual — Installation Instructions
Page 7 · click to enlarge
Page 7
RKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH CT CESEQUIVALENT NUMBER LENGTH x USED =TOTALDUCT PIECESEQUIVALENT NUMBER LENGTH x USED =TOTAL 31⁄ 4″x 10″ Rect., straight1 Ft. x ( ) =Ft.6″Round wall cap with damper24 Ft. x ( ) = (18 ft. w/o damper) x ( ) =Ft. Ft. 7″ Round, straight1 Ft. x ( ) =Ft. 6″ Round roof cap33 Ft. x ( ) =Ft. 6″ Round, straight1 Ft. x ( ) =Ft. 6″ Round to 31⁄ 4″x 10″ rect. transition2 Ft. x ( ) =Ft. 31⁄ 4″x 10″ Rect. 90° elbow14 Ft. x ( ) =Ft. 31⁄ 4″x 10″ Rect. 45° elbow8 Ft. x ( ) =Ft.6″ Round to 31⁄ 4″x 10″ rect. transition 90° elbow4 Ft. x ( ) =Ft. 31⁄ 4″x 10″ Rect. 90° flat elbow33 Ft. x ( ) =Ft. 7″ Round, 90° elbow14 Ft. x ( ) =Ft. 31⁄ 4″x 10″ Rect. wall cap with damper24 Ft. x ( ) = (18 ft. w/o damper) x ( ) =Ft. Ft. 7″ Round, 45° elbow9 Ft. x ( ) =Ft. 7″ Round wall cap with damper28 Ft. x ( ) = (21 ft. w/o damper) x ( ) =Ft. Ft. 31⁄ 4″x 10″ Rect. to 6″ round transition2 Ft. x ( ) =Ft. 7″ Round roof cap39 Ft. x ( ) =Ft. 31⁄ 4″x 10″ Rect. to 6″ round transition 90° elbow4 Ft. x ( ) =Ft. 7″ Round to 31⁄ 4″x 10″ rect. transition1 Ft. x ( ) =Ft. 6″ Round, 90° elbow12 Ft. x ( ) =Ft. 7″ Round to 31⁄ 4″x 10″ rect. transition, 90° elbow5 Ft. x ( ) =Ft. 6″ Round, 45° elbow7 Ft. x ( ) =Ft. Subtotal column 1 =Ft. Subtotal column 2 = Subtotal column 1 = Total ductwork =Ft. Ft. Ft.
Page 8 of the GE Monogram JN327 user manual — Installation Instructions
Page 8 · click to enlarge
Page 8
GE Monogram JN327 — Installation Instructions diagram (page 8)
Fig. 2 · Installation Instructions
GE Monogram JN327 — Installation Instructions diagram (page 8)
Fig. 3 · Installation Instructions
  • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
  • If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
  • If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.
GE Monogram JN327 — Installation Instructions diagram (page 8)
Fig. 4 · Installation Instructions
GE Monogram JN327 — Installation Instructions diagram (page 8)
Fig. 5 · Installation Instructions

66″ or more from the floor to the top of the hood

PARTQUANTITY Grease Filter only (JV338) Charcoal Filter only (JN327 and RN328) Grease Filter and Charcoal Filter (JV347 and JV367)1 1 2 Mounting Screws (8 - 18 x 3/4 Phillips pan head)4 Exhaust Adaptor (for 31⁄ 4″ x 10″ rect. venting)1 Exhaust Adaptor Screw (8 - 18 x 3/8 Phillips pan head or hex head)1
  • NOTES:
  • This range hood is for installation over ranges or cooktops up to 36 ″ wide.
  • If you are going to vent your range hood to the outside, see the “Ducting Requirements” section for exhaust duct preparation.
Page 9 of the GE Monogram JN327 user manual — Installation Instructions
Page 9 · click to enlarge
Page 9
GE Monogram JN327 — Installation Instructions diagram (page 9)
Fig. 6 · Installation Instructions

CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices.

Outside top exhaust (Vertical duct–31⁄4″ x 10″ Rectangular)

Outside rear exhaust (Horizontal duct–31⁄4″ x 10″ Rectangular)

Page 10 of the GE Monogram JN327 user manual — Installation Instructions
Page 10 · click to enlarge
Page 10

REMOVE EXHAUST ADAPTOR If exhausting/venting using the 31⁄4″ x 10″ rectangular duct—optional for JV338, JV347 and JV367 models only: Remove the exhaust adaptor from the inside of the hood. Set it aside along with its mounting screws.

REMOVE WIRING COVER Remove the wiring cover from inside the hood. Set the cover and its mounting screw aside.

31⁄4″ x 10″ rectangular exhaust adaptor and screws

REMOVE WIRING KNOCKOUT Remove either the top or the back wiring knockout as needed and install an approved strain relief clamp.

REMOVE FILTER Remove the shipping tape holding the metal grease filter in place. Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back.

Back knockout Top knockout

REMOVE DUCT KNOCKOUT If recirculating, non-vented ductless (JN327 and RN328, and optional for JV347 and JV367 models only), skip to Step 10 D and proceed. Using a flat blade screwdriver, remove the appropriate duct knockout from the top or back of the hood.

REVERSE THE BAFFLE FOR DUCTED INSTALLATIONS ONLY (JV347 and JV367 models) If the hood is to be recirculated, skip to the next step. Remove the baffle from the top of the hood. Re-install the baffle so the short side marked “VENTED” is visible. The long side of the baffle should be inside the hood.

31⁄4″ x 10″ Rectangular vertical discharge. Remove top rectangular duct knockout only.

7″ Round vertical discharge. Remove circular duct knockout only.

31⁄4″ x 10″ Rectangular horizontal discharge. Remove rear rectangular duct knockout only.

Show 5 more labels / short text on this page
Wiring cover · Strain relief clamp · Strain relief clamp · Metal grease filter · “VENTED” is visible
Page 11 of the GE Monogram JN327 user manual — FOR RECESSED-BOTTOM CABINETS ONLY 10
Page 11 · click to enlarge
Page 11

FOR 31⁄4″ X 10″ RECTANGULAR DUCTED DISCHARGE INSTALLATIONS ONLY: Attach exhaust adaptor/damper over the appropriate knockout opening (for vertical or horizontal, depending on installation) with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.

FOR RECESSED-BOTTOM CABINETS ONLY 10

Wood shims (minimum thickness3/8″)

Exhaust adaptor/damper (vertical discharge position)

Up to 1″ side-to- side adjustment

Pivot (depending on installation)

Exhaust adaptor/damper (horizontal discharge position)

FOR 7″ ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY: Bend up the duct alignment ears in preparation for later attachment of the 7″ duct.

Tape · Top/back edge · Attachment ear tabs

Page 12 of the GE Monogram JN327 user manual — 8 ″ DIA. HOLE
Page 12 · click to enlarge
Page 12

MARK HOLES Select the vent option that your installation will require and proceed to that section:

C. Outside rear exhaust

(Horizontal duct–31⁄4″ x 10″ Rectangular) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

A. Outside top exhaust

(Vertical duct–31⁄4″ x 10″ Rectangular) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Wood shims (recessed-bottom cabinets only–shims must be a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom)

Hood mounting screws (4)

11⁄4″ 1⁄2″

133⁄4″ (30″ hood) 163⁄4″ (36″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) Cabinet front

Horizontal duct access hole Cabinet bottom

33⁄4″

73⁄4″

51⁄4″ 51⁄4″ 73⁄4″ 133⁄4″ (30″ hood) 163⁄4″ (36″ hood)

51⁄4″ 51⁄4″

95⁄8″

133⁄4″ (30″ hood) 163⁄4″ (36″ hood)

11⁄4″

33⁄4″ 1⁄2″

13⁄8″

Electrical access hole (in wall) Hood mounting screws (4)

Electrical access hole (in cabinet bottom) Wood shims (recessed-bottom cabinets only–shims must be a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom)

D. Recirculating (non-vented ductless–

  • JN327 and RN328, and optional on JV347 and JV367 models only)
  • Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots.
  • Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom.

B.Outside top exhaust (Vertical duct–7 ″ Round)

  • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

CUT HOLES Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/4″ extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 101⁄2″ instead of 10″.

133⁄4″ (30″ hood) 163⁄4″ (36″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) Cabinet front

73⁄4″

8 ″ DIA. HOLE

95⁄8″

Access hole for 7″ round duct

11⁄4″

53⁄4″

13⁄8″

Electrical access hole (in cabinet bottom) Wood shims (recessed-bottom cabinets only–shims must be a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom)

RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes. NOTE: DO NOT turn the power on until installation is complete.

Show 10 more labels / short text on this page
Cabinet front · Cabinet Bottom · Vertical duct · access hole · Center line · Center · line · Cabinet bottom · Center · line
Page 13 of the GE Monogram JN327 user manual — Installation Instructions
Page 13 · click to enlarge
Page 13

SCREW IN PARTWAY Drive a mounting screw (from the hardware packet) partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom.

SECURE HOOD Slide the hood back against the wall. Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot.

OPTIONAL POWER CORD KIT JXHC1 An optional Power Cord Connection Kit, model JXHC1, is available at extra cost from your GE supplier for installation using a standard 3-prong, grounded wall outlet. Follow the Installation Instructions packed with the kit to connect the power cord to the range hood.

3-prong wall outlet (if using cord connection) 11⁄4″

CONNECT DUCTWORK TO HOOD (Ducted installations only) On 7″ round installations, attach the 7″ duct with sheet metal screws through the holes in the alignment ears.

73⁄4″

13⁄4″ dia. clearance hole for optional power supply location

7″ round duct

FEED IN WIRES Lift the hood into position and feed the house wiring through the wiring knockout.

Use duct tape to make joints secure and air tight.

Show 5 more labels / short text on this page
Mounting screw (4) · Keyhole (4) · Cabinet · Attachment ear tabs · Duct tape
Page 14 of the GE Monogram JN327 user manual — WIRING section in these Installation Instructions. REPLACE WIRING COVER
Page 14 · click to enlarge
Page 14

23 REPLACE FILTER Make sure fan blade turns freely and replace the filter. NOTE: On model JV347, install the metal grease filter if ducted or the charcoal filter if recirculated.

INSTALL LIGHT BULB NOTE: A light bulb is not shipped with the hood. Obtain one locally. Purchase and install an ordinary screw-base light bulb, not more than 60 watts.

FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes. NOTE: This hood must be permanently grounded. Connect house wiring (120 VAC) to hood wiring.

Metal grease filter or charcoal filter

The installation is complete. Turn on power at service panel, and test for proper operation.

CONNECT WIRING Connect house black to hood black wire, house white to hood white wire and house ground under green ground screw. Securely tighten the strain relief clamp onto the house wiring.

TROUBLESHOOTING CHECKLIST If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following: ❏Knockouts not removed from hood. ❏Damper blade not opening. ❏Reduced airflow because the duct is too small or

the duct length is too long. ❏The duct is blocked. ❏Undersized or restrictive wall or roof cap.

If the hood seems to make excessive noise: ❏Fan may be hitting the filter. Turn off the fan and

remove the filter. Bend the filter down slightly in the center (into a dome shape) to allow fan clearance. Reinstall and adjust as needed.

The fan does not work but the lights do: ❏Switch power off at the service panel and lock the

service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. ❏Check the wiring connections. See the CONNECT

WIRING section in these Installation Instructions. REPLACE WIRING COVER

Green ground screw · Wiring cover

Page 15 of the GE Monogram JN327 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 15 · click to enlarge
Page 15

GE Range Hood Warranty.

Installation Instructions Consumer Support Safety Instructions Operating Instructions

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at ge.com, or call 800.GE.CARES (800.432.2737). Please have serial number and model number available when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: GE Will Replace:

One Year Any part of the range hood which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and original purchase in-home service to replace the defective part.

What GE Will Not Cover:

IService trips to your home to teach you how to use

IDamage to the product caused by accident, fire, floods

the product.

or acts of God.

IImproper installation, delivery or maintenance.

IIncidental or consequential damage caused by possible

defects with this appliance.

IFailure of the product if it is abused, misused, or

used for other than the intended purpose or used commercially.

IDamage caused after delivery.

IProduct not accessible to provide required service.

IReplacement of house fuses or resetting of circuit

breakers.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service Location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 16 of the GE Monogram JN327 user manual — Consumer Support
Page 16 · click to enlarge
Page 16

Consumer Support.

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 7 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 8 · Consumer Support

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 9 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 10 · Consumer Support

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 11 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 12 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Monogram JN327 — Consumer Support diagram (page 16)
Fig. 13 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.

Printed in China

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE Monogram JN327

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE Monogram JN327

Be the first to ask — other owners or our team will answer.

Original document

GE Monogram JN327 manual PDF

16 pages·348 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…