Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
BEFORE YOU BEGIN Read these instructions carefully and completely.
TOOLS YOU WILL NEED
2 Shoulder Screws (for stop device)
1/8” Drill Bit and Electric or Hand Drill
Lower Trim 2 Screws
Junction Box Wire Nuts Strain Relief Clamp for 1/2” conduit
Straight Edge or Square
Hand or Sabre Saw

ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on rating plate. (Rating Plate is located behind the oven door on the range.)
We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your range according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70— Latest Edition. You can get a copy by writing:
National Fire Protection Association Batterymarch Park Quincy, MA 02269
Effective January 1, 1996, the National Electrical Code requires that new, but not existing, construction utilize a four-conductor connection to an electric range. When installing an electric range in new construction, a mobile home, recreational vehicle or an area where local codes prohibit grounding through the neutral conductor, follow the instructions in the section on NEW CONSTRUCTION AND FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION.
You must use a three-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.
Rating plate location

Door removal is not a requirement for installation of the product, but is an added convenience. To remove the door:
Hinge unlocked position Hinge slot
a. Counter opening extends to the wall:
Maintop Filler Kit (JXS66XX), or Backguard Kit (JXS32XX).
b. Island Installation:
To provide an optimum installation, the top surface of the countertop must be level and flat (lie on the same plane) around the 3 sides that are adjacent to range cooktop. Proper adjustments to make the top flat should be made or gaps between the countertop and range cooktop may occur. Forcing the cooktop to fit may cause excessive gaps.
To obtain Kits: a. Visit GE Web Site (See page 1) b. Call GE Answer Center (See page 1) c. Contact Dealer Hinge clears slot
Hinge arm


If cabinets are placed less than 30” min. above the range, see alternate construction.
30” ranges conform to U.L. requirements for 0” spacing from vertical walls below countertops. Allow 1/4” minimum clearance at the back wall above the countertop.
Wall coverings, counters and cabinets around range must withstand heat (up to 200°F) generated by the range.

R
1/4” min. flat
9/16” min. flat 9/16” min. flat
29-15/16”– 30-1/16” smooth cut
Braces secured between the underside of the countertop and the cabinet if required to obtain 1-1/4” minimum thickness (two sides)
The Standard Installation of this Drop-In Range is to hang by the countertop on the side metal flanges under cooktop. This Range must not be installed on a base or sub structure (2”x 4” support).
Center the 30” wide opening over the adjacent cabinets and mark with a straight edge.
Using a straight edge, mark the back line at 23-3/16” from the front edge of the counter.
If the construction of your cabinet cannot provide a 1/4” flat area at the back of the countertop opening, consider changing the countertop to accommodate this dimension.
Be careful not to damage the adjacent cabinets while cutting the countertop.

Remove house fuse or open circuit breaker.
Loosen screws for the junction box cover and rotate out of place or remove the cover.
Examine the junction box location to determine the best routing of the conduit, and select the best available 7/8” diameter knockout. Avoid using holes in the top of the junction box to prevent the conduit from interfering with the back of the range.
GENERAL NOTE FOR ALL WIRE NUT APPLICATIONS: THE PROPER SIZE WIRE NUT SHALL BE PLACED OVER THE STRIPPED LEADS AND THE WIRE NUT TWISTED UNTIL THE WIRE NUT CAN NOT BE PULLED FROM THE LEADS. NO CONDUCTOR SHALL BE EXPOSED IN THE CONNECTION. THE EXCEPTION TO THE CONDUCTOR BEING EXPOSED IS THE BARE COPPER GROUND CONNECTION.
Break open the selected knockout by placing a bladed screwdriver on the scored opening in the junction box and striking the screwdriver with a hammer. (Pliers may be required to complete the removal of the knockout.)
BREAKER OR FUSE SIZE 240V 40 Amps + 208V 40 Amps +
required breaker size.
Cover rotated from box opening
Position the range in front of the opening, but slightly to the side, in a manner so that a person can enter the opening to wire the range to the house wiring in the junction box.
Feed wires and conduit through the open hole and snap the conduit fitting into the hole. Route the conduit in a manner that will not interfere with the rear wire cover. The conduit must be routed below the wire cover.
7/8” knockout

NEW CONSTRUCTION AND FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
When connecting to a 3-conductor branch circuit, if local codes permit:
Connect the bare oven ground conductor with the crimped neutral (white) lead to the branch circuit neutral (white or gray in color), using wire nuts.
Connect the oven red lead to the branch circuit red lead, and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see “WARNING” note (see page 6).
Cut the neutral (white) lead from the crimp. Re-strip the neutral (white) lead to expose the proper length of conductor and connect it to the white or gray branch circuit neutral in accordance with local code using wire nuts.
Attach the appliance grounding lead (green or bare copper) in accordance with local codes. If the residence grounding conductor is aluminum, see WARNING note (see page 6).

Range conduit snaps into box
Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see “WARNING” note (see page 6).
Ground and neutral wires (white)
Neutral bare wire connection
Range conduit snaps into box

Do not shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit within the junction box, do not install the oven until a clamp of the proper size is obtained.
NOTE TO ELECTRICIAN: The 3 power leads supplied with this appliance are UL recognized for connection to larger gauge household wiring. The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.


Select the proper position for the countertop thickness and move bracket to proper position. (Unit is supplied with bracket in position 1.)
The anti-tip bracket is attached to the back of the Drop-In Range. It is designed to fit under the bottom of the countertop opening at the rear. Measure counter thickness at back of cutout to determine correct bracket location.
Bottom of countertop to engage bracket by 1/2” min. Wall stud

INSTALL STOP SCREW
These screws prevent the range from sliding out of position during operation.
It is suggested that two people lift the range into place, carefully setting the side metal flanges on the edges of the countertop opening. Carefully slide the range toward the back of the opening. In the last 1” of travel, lift the front of the range approx. 1/2” to clear the stop screws located in the sides of the cabinet and slide the range until the range is seated. Lower front of the range onto countertop.
Lift and slide range on countertop
Carefully mark the cabinet for the location of the stop screws. Drill 1/8” pilot holes into the cabinet, each side of the range. (Make sure not to drill entirely through the cabinet wall.) Carefully turn the shoulder screws into the pilot holes until they are tight.
Make sure the edge of the countertop fits flush against the end of the Front Control Panel


Attach the lower trim (supplied separately with the range) to the bottom of the vertical side trim with the 2 screws supplied.
Look at both sides of the range under the door. The stop screws must be located in the notch on the sides of the range, and not touch the top of the notch when the range is fully seated on the countertop. If the screws do not meet the requirements, move the screws to a position that meets these requirements. (See illustration below.)
End flange & tab on lower trim fits inside side trim
Notch in bottom of side trim Top flange 1/2” wide

Push the hinge locks up against the front frame of the oven cavity, to the locked position.
Hinge in locked position
Lift the oven door by placing one hand on each side. The door is heavy, so you may need help. Do not lift the door by the handle.
Notch of hinge securely fitted into bottom of hinge slot
With the door at the same angle as the removal position (halfway between the closed and broil stop position, seat the notch of the hinge arm into the bottom edge of the hinge slot. The notch of the hinge arm must be fully seated into the bottom of the slot.
Lower the oven door and gently apply medium force at the handle end until movement of the range is detected. Continue pressing until the anti-tip bracket is engaged and movement stops. A small amount of movement is acceptable at the back of the range top, but it should be stable and not tip once the anti-tip bracket is engaged.
Bottom edge of slot
Hinge arm · Hinge notch


OPTIONAL MAINTOP FILLER OR BACKGUARD KIT
B
When installing in an island or other non-standard location, countertop cutout dimensions must be according to page 5.
If counter opening extends to the wall, it will require Maintop Filler Kit (JXS66XX) or Backguard Kit (JXS32XX) to close the gap.
For the anti-tip bracket instructions, see page 9.
In this application, do not use Backguard Kit (JXS32XX).
If the countertop is less than 25”, a gap will occur between the countertop front and the control panel ends. (See page 10, Step 3).
If a 30” clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained, protect the underside of the cabinets above the cooktop with not less than 1/4” insulating millboard covered with sheet metal not less than 0.0122” thick.
CABINET CUTOUT HEIGHT MORE THAN 27-1/2” USE LOWER TRIM KIT
Optional Lower Trim to fill space beneath 27-1/2” min. requirement (see page 4). Use lower Trim Kit JXS96XX.
Refer to the Filler or Backguard Kit instructions for Installation details.


Printed in the United States 16