g GE Industrial Systems Auxiliary Drive to ISBus Interface Board IS200ADIIH_A_ _ Safety S ymbol Legend Indicates a procedu re or condition that, if not strictl y observed, cou ld resu lt in personal i njury or death .
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 2 Functional Description The IS200ADII Aux iliary ISBus (Innova tion Series ä Bus) Interface board (A DII) interf aces an AcDc2000 driv e to an ISBus Local Area Netw ork (LAN).
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 3 ISBus The ISBus h as one cont roller (drop 0) an d no m ore then 31 nodes (1- 31). The mas ter sends out a s tream of bytes containing each ISBus node's referen ces.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 4 Performance On the ISBus, the con troller sends control bits an d references for each drive in a single st ream of bytes.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 5 Data Mapping The drive is conf igured throug h its keypad or by the toolbox. Once conf igured, the drive exchanges a fix ed set of integer variables with th e controller during each ISBus scan.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 6 Table 4. B oolean S ignals Request Bits Innovation Series bit # Innovation Series Mnemonic AcDc2000 Feedba ck Bits AcDc2.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 7 Table 5. A cDc2000 Refere nces a nd Feedbac k Values (1pu ) Variable AcDc2000 Signal (1pu) Armature Curren t Refr LO.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 8 The LAN watchdog func tion i s made up of t hree par ts: • First, th e LAN Control Processor (LCP) mon itors the ISBus controller’s fault bits and displa ys an ADII f ault, if the ISBus contro ller is in a fault state.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 9 Table 6. Faul t Codes f or ADII Board a nd ISBus Interfa ce Fault No. Fault Name Description Corrective A ction to Take 359 FLT_LINK_LO S (May be set up to monitor AUXCMD.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 10 LNPL COM1 E1 U4 U6 U2 U5 2PL TP1 TP3 TP2 DS5 DS6 E2 P3 P2 TX/OUT RX/IN RX/TX CHASSIS XMIT DATA IN R ELAYS ENABLED P24 P.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 11 LED Indicators The LEDs on the ADII board are only i ntended for diag nostic pu rposes. See Table 7 for a description of the LED indications. The dr ive’s display w ill sho w any ISBus faults or ADII board in terface faults.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 12 Testpoints There are seven tes tpoints on the ADII board as follows: Table 9.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 13 Table 12. Connector LNPL, I/O Between the LDCC Board and ADII Board Pin No.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 14 Table 14. P2 C onnector, R J45 ISBus TX/OUT Pin No. Nomenclature Description 1, 2 NC Not conne cted 3 ISBTXP ISBus tran.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 1 5 Warranty Terms The GE Terms and C onditions brochur e de tail s pr od uct warrant y i nfor mati on, including warranty period and parts and service coverage . The brochure i s included w ith customer docum entation .
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 16 New Installations ADII Required Parts When installing an ADII board in a drive that has not had this board in it previously, GE kit number 277A8496G 01 is re quired.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 1 7 Installation Procedures To prevent electric shock, turn off power to the drive, then test to verify th at no power exists in the drive before touching it or any connected circuits.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 18 Care must b e taken to k eep the ISBu s cables away from any high voltage wires and any electrically noisy wires.
GEI-100305 Auxiliary Driv e to ISBus Inter face Bo ard IS200AD II • • • • 19 Ø Ø Ø Ø To install the new (replac ement) board on the board carrie r 1.
• • • • Auxiliary Drive to ISBus Interface Board IS200ADII GEI-100305 20 Notes g GE Industri al Systems General Elec tric Compa ny 1501 Ro ano ke Blvd. Sal em, V A 24153-6492 US A Issue date: 20 00-04-05 1999 by General E lectric Com pany, USA.
An important point after buying a device GE IS200ADIIH_A_ _ (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought GE IS200ADIIH_A_ _ yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data GE IS200ADIIH_A_ _ - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, GE IS200ADIIH_A_ _ you will learn all the available features of the product, as well as information on its operation. The information that you get GE IS200ADIIH_A_ _ will certainly help you make a decision on the purchase.
If you already are a holder of GE IS200ADIIH_A_ _, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime GE IS200ADIIH_A_ _.
However, one of the most important roles played by the user manual is to help in solving problems with GE IS200ADIIH_A_ _. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device GE IS200ADIIH_A_ _ along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center