Water Softening system

Safety Information 2 Installation Instructions 3–15 Step-by-step instructions 6–15 Operating Instructions Breaking a salt bridge 17 Cleaning the injector and screen 17 Service 16 Water softener system 16–17 Care and Cleaning 18 Troubleshooting Tips 19–21 Advanced Programming 22–23 Advanced Troubleshooting 24–27 Consumer Support Checking the Brine Draw and Refill Function 30 Consumer Support Back Cover Control Valve Diagram/Parts 31, 33 Flow Diagrams 28–29 Systems Diagram/Parts 32, 33 Warranty (U.S.) 34 Warranty (Canada) 35 Water Meter 30

Water Softening

System

Owner’s Manual & Installation Instructions

Write the model and serial numbers here:

To find these numbers, lift the cover and look on the rim below the control panel.

215C1173P030 49-50218-1 04-07 JR

Models GNPR40L, GNPR48L · Model # · Serial #

Page 2 of the GE GNPR40L user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 2 · click to enlarge
Page 2

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.

SAFETY PRECAUTIONS

I Check and comply with your state and local codes.

I Use clean water softening salts only, at least 99.5%

You must follow these guidelines.

pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. These products may contain dirt and sediments, or mush and cake, and will create maintenance problems.

I Use care when handling the water softening

system. Do not turn upside down, drop, drag or set on sharp protrusions.

I Water softening systems using sodium chloride

I Keep the brine tank cover in place on the softener

(salt) for regeneration add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.

unless servicing the unit or refilling with salt.

I The water softening system works on 12 volt-60 Hz

electrical power only. Be sure to use only the included transformer.

I Transformer must be plugged into an indoor

120 volt, grounded outlet only.

PROPER INSTALLATION

This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.

I Install or store where it will not be exposed to

I Softener resins may degrade in the presence of

temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it.

chlorine above 2 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.

I Do not install in direct sunlight. Excessive sun or

heat may cause distortion or other damage to non-metallic parts. Do not attempt to treat water over 100°F.

I Properly ground the system to conform with all

governing codes and ordinances.

I Use only lead-free solder and flux for all

sweat-solder connections, as required by state and federal codes.

I The water softening system requires a minimum

water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 3 of the GE GNPR40L user manual — IMPORTANT INSTALLATION RECOMMENDATIONS
Page 3 · click to enlarge
Page 3

Installation Water Softening System Instructions Models GNPR40L and GNPR48L

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

  • Check with your state and/or local public works department for plumbing codes. You must follow their guides as you install the Water Softening system.

BEFORE BEGINNING INSTALLATION

IMPORTANT INSTALLATION RECOMMENDATIONS (CONT.)

Read these instructions completely and carefully.

  • IMPORTANT — Save these instructions for local inspector’s use.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.

IMPORTANT INSTALLATION RECOMMENDATIONS

  • In the Commonwealth of Massachusetts, Plumbing Code 248 CMR shall be adhered to. Consult with your licensed plumber.
  • Use only lead-free solder and flux for all sweatsolder connections, as required by state and federal codes.
  • Connect the softener to the main water supply pipe before or ahead of the water heater. DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing through the softener must be less than 100°F.
Page 4 of the GE GNPR40L user manual — TOOLS AND MATERIALS REQUIRED FOR INSTALLATION
Page 4 · click to enlarge
Page 4

UNPACKING AND INSPECTION

WHERE TO INSTALL THE SOFTENER

Be sure to check the entire softener for any shipping damage or missing parts. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit.

  • Place the softener as close as possible to a sewer drain, or other acceptable drain point or standpipe.
  • It is recommended to keep outside faucets on hard water to save soft water and salt.
  • Do not install the softener in a place where it could freeze. Freeze damage is not covered by the warranty.

Small parts needed to install the softener are packaged either in a bag or box. To avoid loss of the small parts, keep them packaged until you are ready to use them. Be sure not to discard components hidden in packaging.

  • Do not install the softener where it would block access to the water heater or access to the main water shutoff.
  • Put the softener in a place where water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.

TOOLS AND MATERIALS REQUIRED FOR INSTALLATION

  • Teflon tape
  • A 120-volt electric outlet is needed to plug in the included transformer. The softener has a 10-foot power cable. If the outlet is remote (up to 100 feet), use 18 gauge wire to connect. Be sure the electric outlet and transformer are in an inside location, to protect from wet weather. Be sure the outlet is unswitched to prevent accidental shutoff.
  • Razor knife
  • One adjustable wrench
  • 1/2 ″ vinyl/pvc drain line (the length required will be determined by your specific location)
  • Additional tools may be required if modification to home plumbing is necessary.
  • If installing in an outside location, you must take the steps necessary to assure the softener, installation plumbing, wiring, etc., are as well protected from the elements (sunlight, rain, wind, heat, cold), contamination, vandalism, etc., as when installed indoors. Outdoor installation is not recommended, and voids the warranty.
  • In and out fittings included with the softener are 1 ″ copper adapters. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet. Then, use the necessary adapters to connect the water supply to the 1 ″ copper adapters.
  • Use the included bypass valve to install the softener. The bypass valve allows you to turn off water to the softener for servicing, but still have water pressure in the house pipes.
  • Keep the softener out of direct sunlight. The sun’s heat may distort non-metallic parts and may damage the electronics.
  • Use appropriate fitting/pipe material (i.e., copper, brass, galvanized or CPVC) to connect the 1 ″ copper adapters to the house plumbing.
  • If a rigid valve drain is needed to comply with plumbing codes, you can buy the parts needed to connect a 1/2 ″ copper tubing or plastic pipe drain.
  • Clean nugget or pellet water softener salt is needed to fill the brine tank.
Page 5 of the GE GNPR40L user manual — Installation Instructions
Page 5 · click to enlarge
Page 5
PLAN HOW YOU WILL INSTALL WARNING: Use only lead-free solder and THE SOFTENER flux to prevent lead poisoning. You must first decide how to run the inlet and outlet See Typical Installation Illustration. Use this as a guide pipes to the softener. Look at the house main water when planning your particular installation. Be sure pipe at the point where you will connect the softener. to direct the incoming hard water supply to the Is the pipe soldered copper, glued plastic or softener valve inlet fitting. The valve is marked threaded galvanized? What is the pipe size? IN and OUT. TYPICAL INSTALLATION ILLUSTRATION OPTIONAL 3-VALVE BYPASS INSTALLATION ILLUSTRATION Hard water Hard water to Hard water to M A IN W A T E R P IP E outside faucets outside faucets Soft Hard water M A IN 12V water transformer W A T E R P IP E Soft 1 o2 u0 tlev tolt 12V 120-volt Bypass water transformeroutlet valve Outlet valve Inlet Pipe coupler valve Union nut Adapter Pipe coupler Union nut OUTLET Brine line Adapter OUTLET Brine line Brine tank cover SALT Brine GOES tank cover HERE NOTE: See SALT Drain Hose GOES 3-Valve Bypass Connections HERE System Brinewell section. For soft water Brinewell service: • Open the inlet Fig. 2 Fig. 1 CROSSOVER and outlet CROSSOVER valves Use if water supply flows Use if water supply flows • Close the from the left. Include single from the left. Include single bypass valve or 3-valve bypass. or 3-valve bypass. For bypass hard Soft water: Soft water • Close the inlet water and outlet Hard valves Hard water • Open the water bypass valve To softener To softener inlet From inlet softener From outlet softener outlet TYPICAL INSTALLATION ILLUSTRATION Hard water Hard water to M A IN W A T E R P IP E outside faucets Soft 12V water transformer 120-volt outlet Pipe coupler Union nut Adapter OUTLET Brine line Brine tank cover SALT GOES HERE NOTE: See Drain Hose Connections Brinewell section. Fig. 1 CROSSOVER Use if water supply flows from the left. Include single or 3-valve bypass. Soft water Hard water To softener inlet From softener outletOPTIONAL 3-VALVE BYPASS INSTALLATION ILLUSTRATION Hard water to outside faucets Hard water M A IN W A T E R P IP E Soft 12V 120-volt Bypass water transformeroutlet valve Outlet valve Inlet valve Pipe coupler Union nut Adapter OUTLET Brine line Brine tank cover SALT GOES 3-Valve Bypass HERE System For soft water Brinewell service: • Open the inlet Fig. 2 and outlet CROSSOVER valves Use if water supply flows • Close the from the left. Include single bypass valve or 3-valve bypass. For bypass hard Soft water: water • Close the inlet and outlet Hard valves water • Open the bypass valve To softener inlet From softener outlet
Page 6 of the GE GNPR40L user manual — MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION
Page 6 · click to enlarge
Page 6

BEFORE YOU BEGIN

OPERATION

  • Turn off the gas or electric supply to the water heater, in the possibility that the water heater may be drained while draining pipes.

To bypass the Water Softener with the bypass valve, rotate the handles clockwise so they are both perpendicular to the flow path of the inlet and outlet water stream, as shown below.

  • Turn off the water supply to pipes to be cut and drain the house water pipes.
  • Open both hot and cold faucets at the lowest location possible.

INSTALL BYPASS VALVE

  • Make sure there is a gasket secured inside the inlet and outlet union nuts of the bypass. Then assemble the union nut to the valve inlet and outlet, hand-tightening both union nuts simultaneously. It is not necessary to lubricate or use sealant on the rubber gaskets or union nuts.

To return to the conditioned water or service position, rotate the handles counterclockwise so they are parallel to the flow path of the inlet and outlet water stream, as shown below.

  • Insert copper adapters through union nuts. Place the rubber gaskets into the union nuts and assemble to bypass valve. It is not necessary to lubricate or use sealant on rubber gasket or union nuts.

MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION

Before sliding softener in position, be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener. Slide softener into position.

Show 21 more labels / short text on this page
Valve outlet · Outlet union nut · Valve inlet · Bypass valve · Gaskets · Outlet · Inlet union nut · Inlet · Valve outlet · Valve inlet · Inlet · Copper adapters · Outlet · Union nut · Gasket · Union nut · Valve outlet · Valve inlet · Copper adapters · Outlet · Inlet
Page 7 of the GE GNPR40L user manual — FLOOR DRAIN
Page 7 · click to enlarge
Page 7
  • PLUMB “IN” AND “OUT” PIPES TO AND FROM SOFTENER CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing. See Typical Installation Illustration.
  • BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE SOFTENER VALVE INLET PORT. If house water flow is from the right, use a plumbing crossover as shown in Typical Installation Illustration.
  • With the softener in place, determine the correct length of piping required to connect the household plumbing to the 1 ″ copper adapter on the softener. Test fit all connections. NOTE: The softener must not support the home’s plumbing in the vertical direction. Secure the inlet and outlet pipes to the wall/ceiling using pipe clamps or straps. Be certain the home’s plumbing does not exert any force on the softener bypass.
  • Remove softener from installation space.
  • Disconnect copper adapters and union nuts from bypass valve.
  • Reconnect copper adapters with union nuts and gaskets in place to home plumbing. Before soldering adapters, slide union nuts and gasket away from area being soldered. NOTE: Torch heat will damage plastic parts.
  • Support inlet and outlet plumbing in some manner (use pipe hangers or clamps) to keep the weight off of the valve fittings.
  • Slide softener back into position.
  • Make final connections to the bypass valve.

CONNECT AND RUN THE VALVE DRAIN HOSE (CONT.)

  • Locate the other end of the hose at a suitable drain point (floor drain, sump, laundry tub, etc.) that terminates at the sewer. Check and comply with local codes.
  • Tie or wire the hose in place at the drain point. High water pressure will cause it to whip during the back-wash and fast rinse cycles of regeneration. Also provide an air gap of at least 1-1/2 ″ between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water into the softener, if the sewer should “back-up.”

The water softener will not work if water cannot exit this hose during regeneration.

  • Elevating the drain hose may cause back pressure that could reduce the brine draw during regeneration. If raising the drain line overhead is required to get to the drain point, measure the inlet water pressure to the softener first. For inlet pressures between 20 and 50 psi, do not raise higher than 8 ′ above the floor. For inlet pressure above 50 psi, the drain line may be raised to a maximum height of 14 ′ .

STANDPIPE

LAUNDRY TUB

CONNECT AND RUN THE VALVE DRAIN HOSE

Tie or wire hose in place

  • Check that drain port on valve body has white tape on it. If not, apply Teflon Tape to threads prior to installing the valve drain fitting.
  • Connect valve drain fitting to valve drain port. Tighten connection with a wrench.
  • Connect 1/2 ″ diameter drain hose (not provided) to the valve drain fitting. Tighten connections with wrench.

SUMP

11⁄2″ air gap

FLOOR DRAIN

Valve drain hose connection

Valve drain hose

Page 8 of the GE GNPR40L user manual — BRINE TUBING CONNECTION
Page 8 · click to enlarge
Page 8
GE GNPR40L — Step-by-step instructions diagram (page 8)
Fig. 1 · Step-by-step instructions

INSTALL GROUNDING WIRE AND CLAMPS

  • Connect overflow drain hose to fitting on side of brine tank.

IMPORTANT: A copper or galvanized house cold water pipe is often used to ground electrical outlets in the home. Grounding protects you from electrical shock. The water softener may have broken this ground path. To restore connection, install UL approved grounding hardware or 6-gauge copper wire across the softener valve, tightly clamped, using UL approved grounding clamps at both ends as shown. Zinc clamps should not be used on copper plumbing. Grounding hardware is not provided with the unit. It may be purchased separately from your local hardware store.

  • Locate the other end of the hose at the drain point. DO NOT ELEVATE this hose higher than the elbow on the brine tank.

BRINE TUBING CONNECTION

Connect brine tube to clear air check assembly on the main valve:

  • Route brine tube through 1 ″ hole in brine tank above hose adapter.
  • Connect tubing to 90° fitting on top of float assembly. Press in firmly to fully seat in fitting.
Show 10 more labels / short text on this page
To valve inlet · Ground Clamp · From valve outlet · Valve assembly · Brine tube connection · Brine tubing · To valve assembly · Brine tube connection · Float assembly · Brine tube
Page 9 of the GE GNPR40L user manual — 5 PURGE THE SYSTEM
Page 9 · click to enlarge
Page 9

START-UP RINSING PROCEDURE

(BYPASS VALVE IS OPTIONAL)

OPEN WATER SUPPLY

RUN THE WATER

With the plumbing, drain line and overflow connections completed, slowly open the water supply, allowing the lines to pressurize.

After the 20-minute purge cycle, manually advance the main gear to the backwash cycle and allow to run for a minimum of 10 minutes.

After 10 minutes during the backwash cycle, open both the inlet and outlet valves on the bypass to the fully opened position.

ADVANCE THE CONTROL VALVE

With the transformer unplugged, manually advance the control valve by depressing the drive gear and rotating the main system gear to the purge position (see Step 4).

Advance the gear in the counterclockwise direction only. Damage will occur if advanced in the opposite direction.

5 PURGE THE SYSTEM

FILL BRINE TANK

After the ten-minute backwash cycle, manually advance the control valve to the brine refill position for ten minutes, allowing water to flow into the brine storage tank.

Slowly open the inlet valve (only) on the bypass valve to the half-opened position, allowing the system to pressurize. It is normal to hear air blowing to the drain during this procedure.

Once the air clears and water begins to run to the drain, open the inlet valve (only) to the full open position and allow the water to run to the drain in purge for a minimum of 20 minutes.

Once water begins to flow into the tank, fill the brine tank with a minimum of 80 lbs. of salt pellets.

Outlet Inlet · Outlet Inlet

Page 10 of the GE GNPR40L user manual — INSTALL 9V BATTERY FOR BATTERY BACKUP FEATURE
Page 10 · click to enlarge
Page 10

ADVANCE CONTROL VALVE TO SERVICE POSITION

INSTALL 9V BATTERY FOR BATTERY BACKUP FEATURE (CONT.)

After the ten-minute refill time, manually advance the control valve to the service position.

To install a battery:

1. Remove the control valve cover.
2. The battery pocket is located in the upper left corner of the control as shown.
3. Connect the battery, matching up negative and positive posts.

CONNECT TO ELECTRICAL POWER

4. Insert battery into holder located on the back of the control panel. Make sure terminal wires are routed away from the valve gears.
  • The softener works on 12 volt60Hz electric power. The included transformer changes standard 120-volt AC house power to 12 volts DC. Connect transformer to control panel. Plug is located on the bottom left of the control panel. Plug the transformer into a 120volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake.

Connect transformer to control panel

INJECTOR SELECTION

  • The injector is critical to the proper flow through the resin tank during the regeneration cycle. The injector supplied with the unit from the factory is applicable to installations with supply water pressure up to 70 psi.
  • If supply water pressure is greater than 70 psi, injector assembly WS15X10059 should be installed.

INSTALL 9V BATTERY FOR BATTERY BACKUP FEATURE

Water PressureInjectorPart Number 20–70 psi5 bumpsWS15X10060 70–125 psi4 bumpsWS15X10059

Your softening system has a battery backup feature that allows the control to continue monitoring water flow and maintain the proper time of day during short power outages. The control uses a standard 9-volt battery (not supplied).

During a power outage, the display will be turned off and the motor will not run, but the control will continue to monitor water flow and time. If power is out and a regeneration is needed, the regeneration will be delayed until power is restored. If power is lost during the regeneration, the control will resume the regeneration when power is restored.

While batteries may last for over a year, it is recommended that you replace the battery every year. During an interruption in power supply, a typical new 9-volt alkaline battery provides approximately 40 hours of power for the control.

If there is a power outage, after power is restored, verify that the time in the control is correct. If it is, system is OK. If time is incorrect, set the correct time in the control and replace the 9-volt battery. If system has been without power for over 24 hours, initiate an immediate regeneration cycle by pressing the REGEN button.

Injector · Injector cap

Page 11 of the GE GNPR40L user manual — PROGRAMMING THE CONTROL
Page 11 · click to enlarge
Page 11

PROGRAMMING THE CONTROL

PROGRAMMING THE CONTROL

SET PRESENT TIME OF DAY

GE GNPR40L — PROGRAMMING THE CONTROL diagram (page 11)
Fig. 2

The green indicator lights up next to the name of the active control setting.

Press UP or DOWN button to select TIME OF DAY.

Pressing the DOWN button displays the settings in order. By continuing to press the DOWN button, the settings start over, beginning with the time of day. Pressing the UP button displays the settings in reverse order.

1. Press the SET button. The display will show the time of day with the minutes blinking.
2. Press UP or DOWN button to set. The UP button advances the digit; the DOWN button moves the digit in reverse.

To change the settings, press the SET button on the top right. A digit on the display will start to flash. If you want to change this number, press the UP button to increase the number or the DOWN button to decrease the number.

When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing. You can only change the flashing number.

When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing.

If the present time is between noon and midnight, be sure PM indicator light is on. If the present time is between midnight and noon, be sure PM indicator light is off.

To skip the number without changing, press the LEFT

button. When you reach the far left digit, press the LEFT button to return to the digit on the right.

To change AM/PM, advance the far left digit. The digit will alternate between 0 and 1. As the digit alternates, the PM light will turn on and off.

You can only change the flashing digit. Continue changing numbers until you reach the desired setting. Press the SET button. The numbers stop flashing and the control accepts the new settings. After approximately 30 seconds, the control starts alternating the display between TIME OF DAY and CAPACITY.

3. When the present time is correct, press SET to accept.

PM Indicator · light

Page 12 of the GE GNPR40L user manual — To change:
Page 12 · click to enlarge
Page 12

TIME OF REGENERATION

SALT PER REGEN AND CAPACITY

The system has a default setting of 2:00 a.m.

These two settings are required to provide the most efficient operation of the system in your installation.

To change:

Salt efficiency is improved by regenerating part of the capacity. For example, the GNPR40 has 37,100 grains of capacity. It is more efficient to regenerate 20,000 grains of capacity more frequently than waiting and regenerating the complete 37,100 grains.

  • Use the UP or DOWN button to select a new time for regeneration.
  • Use procedure in SET PRESENT TIME OF DAY .
  • Press the SET button to accept.

GNPR40L

30 25 20 15 10 5 0 0 10 20 30 40 50

TOTAL WATER HARDNESS

Water hardness is the hardness of the supply water to the house in grains per gallon. The system has a default setting of 25 grains/gallon.

A water test should be performed at the time of installation to determine your water hardness (grains/gallon). You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory. If you are on a municipal supply, call your local water department. If your report shows hardness in parts per million (ppm), simply divide by 17.1 to get the equivalent number of grains per gallon.

GNPR48L

30 25 20 15 10 5 0 0 10 20 30 40 50

To change:

  • Use the UP or DOWN button to select total water hardness.
  • Press the SET button.
  • Change the digits by using the UP , DOWN or LEFT button.
  • Press the SET button to accept.

Both SALT PER REGEN and CAPACITY are determined based on the chart on page 13.

FOR CALIFORNIA INSTALLATIONS: • California regulations require the control setting to yield 4,000 grains of capacity per pound of salt. To meet these requirements, the SALT PER REGEN and CAPACITY must be set no higher than indicated below:

ModelCapacity DefaultSalt Default GNPR40L16.5 KGr4.0 lbs GNPR48L15.2 KGr3.6 lbs
Show 4 more labels / short text on this page
Salt Setting (lbs) · Capacity (1,000 grains) · Salt Setting (lbs) · Capacity (1,000 grains)
Page 13 of the GE GNPR40L user manual — How to determine correct salt dosage and capacity:
Page 13 · click to enlarge
Page 13

SALT PER REGEN AND CAPACITY (CONT.)

SYSTEM CAPACITY INPUTS

Example of Lbs of Salt req. per regen

CAPACITY (x 1,000) GNPR40L GNPR48L 3.0 14.140 N/A 3.6 15.5 15.248

How to determine correct salt dosage and capacity:

4.0 16.5 15.5 5.0 19.0 18.0 6.0 22.0 21.0 7.0 24.0 23.5 7.5 24.440 24.3 8.0 25.6 25.0 9.0 27.9 26.148

The correct salt dosage and capacity are determined based on the family size and water hardness. Use the following procedure and example:

  • Daily Water Usage = number of persons in household x 80 gallons

For a family of 3 Daily Water Usage = 3 x 80 = 240 gallons/day

10.0 30.0 30.0 11.0 31.9 31.5 12.0 33.6 33.0 13.0 35.1 34.0 14.0 36.4 35.2 15.0 37.140 36.0 16.0 N/A 37.0 17.0 N/A 38.0 18.0 N/A 39.8 19.0 N/A 41.0 20.0 N/A 41.5 21.0 N/A 42.0 22.0 N/A 43.0 23.0 N/A 44.0 24.0 N/A 45.2 25.0 N/A 45.9 26.0 N/A 46.5 27.0 N/A 47.2 28.0 N/A 48.948

  • Water Hardness – have the water tested or call your local water company. For this example, 20 grains is assumed.
  • Calculate total grains used per day = gallons/day x hardness = grains/day

240 gallons/day x 20 grains = 4,800 grains/day

  • Water softener should be set to regenerate every 5 days.

Req Capacity = 5 days x 4,800 grains/day = 24,000

  • Use SYSTEM CAPACITY INPUT table to select capacity and determine lbs of salt per regeneration.

For GNPR40 use setting at 24,000 grains.

  • Program the control:
Capacity24,000 grains
Lbs of Salt7.0

If water supply has a high level of sediment or iron, set system to regenerate every 3 days:

40GNPR40L certified capacity at salt setting 48GNPR48L certified capacity at salt setting

  • Use the UP or DOWN button to select SALT PER REGEN .
  • Press the SET button.
  • Use the UP , DOWN and LEFT buttons to select SALT PER REGEN amount.
  • Press the SET button to accept.
  • Use the UP or DOWN button to select CAPACITY .
  • Press the SET button.
  • Use the UP , DOWN and LEFT buttons to select correct capacity.
  • Press the SET button to accept.
Page 14 of the GE GNPR40L user manual — SOUNDS YOU WILL HEAR
Page 14 · click to enlarge
Page 14

NORMAL OPERATION

ERROR CODES

The control will cycle between TIME OF DAY and CAPACITY about every 10 seconds, as indicated by the green indicator light.

This system continuously monitors itself and displays an error message if it detects something wrong. This typically happens when the valve has not advanced through the regeneration cycle properly.

Capacity in Normal Operation mode is the gallons of water available until the next regeneration cycle.

When an error is detected, the display shows the letters “Err” with a number from 1 to 4. The table on page 24 describes each error, the cause of the error and the solutions.

During a regeneration cycle, the control will cycle between TIME OF DAY and REGEN TIME REMAINING.

REGEN TIME REMAINING is the number of minutes until the regeneration cycle is complete.

To clear the error from the display, press any button on the control. If the error still exists, the control will display the error message again after 30 seconds.

MANUAL REGENERATION

Occasionally you may find it necessary to initiate a manual regeneration. This is done by pressing the REGEN button on the front of the display. When you press the REGEN button, the control performs a full regeneration of the water conditioner immediately.

SOUNDS YOU WILL HEAR

During the regeneration cycle, the softener makes several sounds. These sounds are normal.

  • Clicking sound – This occurs as the valve assembly advances. It is the opening and closing of the valve ports.

In the event the system is allowed to run out of salt, it will be necessary to run “Back to Back” regenerations. This can be done easily by pressing the REGEN button one time, waiting at least one minute and pressing the REGEN button again.

  • Harmonic sound – As the valve transitions between cycles in regeneration, a high-pitched harmonic noise may be heard for a few seconds.
  • Water flow sound – In the backwash and purge portions of the regeneration, water flow is very high – 2–3 gpm. This is required to flush the tank of accumulated minerals and sediments.

“Back to Back” regenerations are necessary if full exhaustion occurs due to low regenerate levels or system malfunction. The system works on a highly efficient proportionate-brining method. When the system is not aware of the lack of proper regenerate (salt), a larger portion of the resin bed becomes exhausted.

REGEN button

Page 15 of the GE GNPR40L user manual — GNPR40L GNPR48L
Page 15 · click to enlarge
Page 15

SANITIZING PROCEDURES

To complete the installation, do the following sanitizing procedures.

4. If, after sanitization, water from the house faucet tastes salty or has a slight color, this is a preservative from the resin tank. Turn on the cold soft water faucets and drain for a few minutes or until clear.

Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installation and operation, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.

NOTE: When the sanitizing regeneration is over, all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above regeneration, drain the water heater until the water runs cold.

1. Be sure to complete all installation steps, including programming the control.
2. Pour about 3/4 oz. (1 1 ⁄ 2 tablespoons) of common 5.25% unscented household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc.) into the brinewell . Refer to illustration on page 5.
3. IMPORTANT: Press and hold for 3 seconds the faceplate REGEN button to start an immediate regeneration. The indicator light will alternate between TIME OF DAY and REGEN TIME REMAINING. The bleach will be drawn through the water softener, and out the drain. This process takes approximately 3 hours.

141⁄2″

SPECIFICATIONS/DIMENSIONS

GNPR40L GNPR48L

Resin Tank Size 10x44″ 12x48″

Resin Volume 1.25 ft3 1.50 ft3

Refill Controller 0.35 gpm 0.35 gpm

Backwash Controller 2.8 gpm 2.8 gpm

47″ 401⁄4″

Brine Tank Size 15x40″ 15x40″

Capacity 350 lbs 350 lbs

Operation Temperature Min. 34° 34°

Max. 100°F 100°F

15″ 10″

Flow Rate 15.2 gpm 18.0 gpm

151⁄4″

Pressure Drop 15.0 psi 15.0 psi

Maximum Flow to Drain 4.0 gpm 3.5 gpm

These systems conform to WQA NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data. * Testing was performed using pellet grade sodium chloride as the regenerant salt. ** Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to WQA NSF/ANSI 44. *** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal® Red•Out® or Super Iron Out® will improve iron removal. Refer to Cleaning Iron Out of the Water Softening System section.

541⁄4″

511⁄4″

401⁄4″

50″ · 15″ · 12″

Page 16 of the GE GNPR40L user manual — Automatic Hard Water Bypass During Regeneration
Page 16 · click to enlarge
Page 16

About the water softener system.

Service

When the water softening system is providing soft water, it is called “Service.” During service, hard water flows from the house main water pipe into the water softening system. Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hard minerals. This is called ion-exchanging. It is much like a magnet attracting and holding metals. Water without hard minerals (soft water) flows from the water softening system and to the house pipes.

After a period of time, the resin beads become coated with hard minerals and they have to be cleaned. This cleaning is called regeneration. The regeneration cycle is started at 2:00 AM (factory setting) by the water softening system control, and consists of five stages or cycles. These are FILL, BRINING, BRINE RINSE, BACKWASH and FAST RINSE.

Automatic Hard Water Bypass During Regeneration

For emergency needs, hard water is available to the home during the regeneration cycles.

However, you should avoid using HOT water because the water heater will fill with the hard water.

Fill Salt dissolved in water is called brine. Brine is needed to clean the hard minerals from resin beads. To make the brine, water flows into the salt storage area during the fill stage.

Backwash During backwash, water travels up through the resin tank at a fast flow rate, flushing accumulated iron, dirt and sediments from the resin bed and to the drain.

Brining During brining, brine travels from the salt storage area into the resin tank. Brine is the cleaning agent needed to remove hard minerals from the resin beads. The hard minerals and brine are discharged to the drain.

Fast Rinse Backwash is followed by a fast flow of water down through the resin tank. The fast flow flushes brine from the bottom of the tank, and packs the resin bed.

After fast rinse, the water softening system returns to soft water service.

The nozzle and venturi create a suction to move the brine, maintaining a very slow rate to get the best resin cleaning with the least salt.

Brine Rinse After a pre-measured amount of brine is used, the brine valve closes. Water continues to flow in the same path as during brining, except for the discontinued brine flow. Hard minerals and brine flush from the resin tank to the drain.

Page 17 of the GE GNPR40L user manual — Breaking a Salt Bridge
Page 17 · click to enlarge
Page 17

ge.com

Breaking a Salt Bridge

Sometimes, a hard crust or salt bridge forms in the salt storage area. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space forms between the water and salt. Then salt will not dissolve in the water to make brine.

Push tool into salt bridge to break

GE GNPR40L — Breaking a Salt Bridge diagram (page 17)
Fig. 3 · Breaking a Salt Bridge

If the brine tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. The following is the best way to check for a salt bridge.

Salt should be loose all the way to the bottom of the tank. Take a broom handle or like tool, and carefully push it down into the salt, working it up and down. If the tool strikes a hard object (be sure it’s not the bottom or sides of the tank), it’s most likely a salt bridge. Carefully break the bridge with the tool. Do not pound on the walls of the tank.

If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. In humid areas, it is best to fill with less salt, more often to prevent a salt bridge from forming.

GE GNPR40L — Breaking a Salt Bridge diagram (page 17)
Fig. 4 · Breaking a Salt Bridge

A clean injector and screen is needed for the water softening system to work properly. This small unit makes the suction to move brine from the brine tank storage area to the resin tank during regeneration. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water. This will be evident by a high level of water in the brine tank—over 4″ when the system is in service mode.

Injector screen and cap installation

  • TO CLEAN:
  • Put system in Bypass mode and relieve water pressure.
  • Remove injector screen (a flat-head screwdriver is required).
  • Remove injector cap and injector (needle nose pliers are required).
  • Clean and flush thoroughly.
  • Check for damage.
  • Reassemble injector and injector screen.
  • To check proper operation, see page 30, Checking the Brine Draw and Refill Function .
  • Initiate REGEN cycle to restore resin bed. A back-to-back regeneration is suggested. Excess water in the brine tank will be removed.
Show 5 more labels / short text on this page
Salt · Broom handle · Salt bridge · Water level · screen
Page 18 of the GE GNPR40L user manual — Cleaning Iron Out of the Water Softening System
Page 18 · click to enlarge
Page 18

Care and cleaning of the water softening system.

Checking the Salt Storage Level and Refilling

Brine (salt dissolved in water) is needed for each and every regeneration. The water for making brine is metered into the salt storage area by the water softening system valve and control. However, you must keep the tank supplied with salt.

CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

Cleaning Iron Out of the Water Softening System

Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.

IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and regenerate the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.

The control has an adjustable backwash cycle. The backwash can be lengthened to better flush the resin bed from high sediment or iron situations. See the Advanced Control Setting section or consult an installer.

GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

Also set LBS OF SALT and CAPACITY so the system will regenerate about every 3 days. See page 13.

Page 19 of the GE GNPR40L user manual — Problem Possible Causes What To Do
Page 19 · click to enlarge
Page 19

Before you call for service… ge.com

Troubleshooting Tips Save time and money! Review the chart on these pages first and you may not need to call for service.

  • NO SOFT WATER – Most Common Problems: Check the following before calling for service:
  • Not enough salt—brine tank should be at least 1/3 full.
  • Bypass valve in “Bypass” position—flange on knobs should be in line with pipes (see page 6).
  • Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply water—from local water company, water test or call the GEAnswer Center.
  • Salt Bridge—salt solidifies above water level so that brine water is not in contact with salt. See the Breaking a Salt Bridge section.

Problem Possible Causes What To Do

No soft water Faucet or fixture where sample was • To conserve salt, the installer may have isolated some fixtures taken not plumbed to soft water. (outside faucets, toilets, etc.) from soft water. From the outlet NOTE: Be sure sample is from a faucet of the water softening system, trace the water flow path, that does not mix soft and hard water. in house plumbing. If soft water is not directed to a faucet For example, a single lever kitchen faucet, or fixture where wanted, consult a plumber. if the cold side is plumbed to hard water.

No salt in the brine tank or • Check for a salt bridge or, if the tank is empty, refill with salt bridged recommended salt. Press (for 3 seconds) the REGEN button to start an immediate regeneration and restore soft water supply. See page 17, Breaking a Salt Bridge.

Transformer unplugged at wall outlet or • Check for a loss of electrical power to the water softening power cable to softener not connected. system, due to any of these conditions and correct as needed. Fuse blown or circuit breaker popped With the power supply restored, observe the faceplate time on circuit to electrical outlet. display and read Programming the Control section. Electrical outlet on a circuit that can NOTE: The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off.

Manual bypass valve in bypass position • Be sure the flange on the bypass valve knobs are in line with

the pipes.

Valve drain hose pinched, plugged, • Any restriction in this drain hose may prevent proper elevated too high or otherwise operation of the nozzle and venturi and reduce or prevent restricted brine draw during regeneration.

Injector and injector screen dirty, • This will be evident by a high level of water in the brine tank. incorrectly assembled or damaged Water level will be greater than 4″ when the system is in the service position.

  • Refer to Cleaning the Injector and Screen instructions. With water pressure to the water softening system off, remove the injector and injector screen. Thoroughly clean and flush. Check for any damage. Reassemble to valve assembly.

If resin bed is fully exhausted, for • Complete “back to back” regenerations. Initiate Regeneration example, after a malfunction, one cycle, wait 1 minute, then press REGEN again. regeneration cycle may not fully See page 14. restore capacity

Page 20 of the GE GNPR40L user manual — Problem Possible Causes What To Do
Page 20 · click to enlarge
Page 20

Before you call for service…

Problem Possible Causes What To Do

Water hard sometimes Using hot water while the water • Avoid using hot water during water softening system softening system is regenerating regeneration because the water heater will refill with hard water.

Control HARDNESS number setting • Press the SET button to enter a new value. Be sure the too low number shown is the same as the actual grains per gallon hardness of your water supply. See the Programming the Control section if a change in the setting is needed.

Grains of hardness in your water • Water hardness can change over time, especially in well water. supply have increased To check, have the water tested by a water analysis laboratory or call your local water department. Adjust the hardness number setting as needed.

System capacity inputs, Salt per • See Salt per Regen and Capacity section so system will Regeneration and Capacity set too low regenerate about every 5 days. See instructions on pages 12 and 13.

If resin bed is fully exhausted, for • Complete “back to back” regenerations. Initiate Regeneration example, after a malfunction, one cycle, wait 1 minute, then press REGEN again. regeneration cycle may not fully See page 14. restore capacity

Water feels slippery Absence of hardness minerals • This is normal. Hardness in water gives it the abrasive feel after installation of you may have been accustomed to. The slippery feel is the water softening system clean feel of soft water.

Water softening system Water softening system is a • Does not use much salt to regenerate—very efficient. not using any salt “demand” unit

Possible salt bridge • See the Breaking a Salt Bridge section.

Possible plugged injector and screen • See the Cleaning the Injector and Screen section.

Water is blue color Acidic water in copper plumbing • Have the water tested at once. after water softening system was installed

Cloudiness on glassware Combination of soft water and • This is called etching and is permanent. To prevent this (automatic dishwashers) too much detergent from happening, use less detergent if you have soft water. Wash glassware in the shortest cycle that will get them clean.

Excessive/high level Valve drain hose pinched, • Any restriction in this drain hose may prevent proper of water in brine tank plugged, elevated too high operation of the injector and screen and reduce or prevent or otherwise restricted brine draw during regeneration.

Injector or injector screen dirty • See the Cleaning the Injector and Screen section, page 17. With water pressure to the water softening system off, remove the injector and injector screen. Thoroughly clean and flush. Check for any damage. Reassemble to valve assembly.

Troubleshooting Tips

Page 21 of the GE GNPR40L user manual — Problem Possible Causes What To Do
Page 21 · click to enlarge
Page 21

ge.com

Problem Possible Causes What To Do

  • Salty tasting or Unit not sanitized
  • Complete the Sanitizing Procedures on page 15. brown/yellow colored
  • At completion of regeneration cycle(approx. 2 hrs), run water water after installation from faucets to purge the salty water.

Low water pressure Check pressure. • Drain height 8′ or less, pressure should be minimum of 20 psi.

  • Drain height above 8 ′ , pressure should be minimum of 50 psi.

Restricted drain hose • Clean and reconnect drain line.

  • Check for kinks in drain line.

Brown/yellow Unit was idle for a period of time • Complete the Sanitizing Procedures on page 15. colored water

Sounds you might hear Running water from the unit • This is normal. High water flows in backwash cycle, flushes during regeneration into a drain during regeneration minerals and sediments from resin tank. cycle

Harmonic noises during regeneration • This is normal.

Clicking • This is normal. This is the sound of various valves opening and closing as valves cycle through regeneration cycle.

Water has air bubbles Air in system after installation • Will go away after it runs for a while. and is cloudy

Page 22 of the GE GNPR40L user manual — Advanced Programming Parameters
Page 22 · click to enlarge
Page 22

Advanced programming and troubleshooting section.

To access advanced programming, simultaneously hold down the UP and DOWN buttons. This will allow you to enter advanced programming settings P6 through P19 (see table below).

This section was designed for the use of water treatment professionals. Default settings are based on water conditions at a typical installation. Before making any changes, consult a water treatment professional, as incorrect settings may result in a system malfunction. Programming the control is not covered under the warranty.

Advanced Programming Parameters

Minimum Units Parameter Description Range Increments of Measure Notes

P6 Refill controller 1–99 1 gpm 0.33 gpm, both models

P7 Brine draw value 1–99 1 Minutes 40L – 15 and 48L – 16

P8 Not used N/A

P9 Backwash time 3–30 1 Minutes Skip this parameter to accept the default or enter a value.

P10 Slow rinse time 8–125 1 Minutes GNPR40L = 67 GNPR48L = 83

P11 Fast rinse time 2–19 1 Minutes Skip this parameter to accept the default or enter a value.

P12 Units of measure 0–1 1 0 = U.S. 1 = Metric Skip this parameter to accept the default (U.S.).

P13 Clock mode 0–1 1 0 = 12-hour clock 1 = 24-hour clock Skip this parameter to accept the default (12-hour).

P14 Calendar override 0–30 1 days 0 = no calendar override Skip this parameter to accept the default (no override).

P15 Reserve type 0–3 1 0 = variable reserve

P16 Fixed reserve capacity 0–70 1 percent of capacity Description depends on the value or initial average value entered for P15 (Reserve type). Skip this parameter to accept the default.

P17 Operation type 0–1 1 0 = Not used 1 = 5-cycle counter current

P18 Salt/capacity change 0–1 1 0 = None lock out 1 = salt/capacity change locked out Skip this parameter to accept the default (no lock out).

P19 Factory defaults DO NOT 1 Loads in factory default values. DONOT CHANGE CHANGE THIS PARAMETER.

Page 23 of the GE GNPR40L user manual — Advanced Programming Parameters
Page 23 · click to enlarge
Page 23

ge.com

Default Settings

The following table represents preset values programmed into the system at the factory for both levels for the model shown.

Required Parameters

Name Description GNPR40L GNPR48L

P1 Time of day Set in field Set in field

P2 Time of regeneration 2:00 a.m. 2:00 a.m.

P3 Hardness Set in field (25 grains) Set in field (25 grains)

P4 Salt amount 7.5 lbs 9.0 lbs

P5 Capacity 24.4 Kgr 26.1 Kgr

Advanced Programming Parameters

Name Description GNPR40L GNPR48L

P6 Refill controller 0.33 gpm 0.33 gpm

P7 Brine draw value 15 min. 16 min.

P8 Not used N/A N/A

P9 Backwash time 12 min. 12 min.

P10 Slow rinse time 67 min. 83 min.

P11 Fast rinse time 4.0 min. 4.0 min.

P12 Units of measure 0 0

P13 Clock mode 0 0

P14 Calendar override 0 0

P15 Reserve type 0 0

P16 Fixed reserve capacity N/A N/A or initial average value

P17 Operation type 1 1

P18 Salt/capacity change 0 0 lock out

P19 Factory defaults 9 9

Page 24 of the GE GNPR40L user manual — Error Detection Codes
Page 24 · click to enlarge
Page 24

Advanced troubleshooting.

Manual Indexing for Each Regeneration

Errors

The control valve may be manually indexed to each regeneration position as follows:

This system continuously monitors itself and displays an error message if it detects something wrong.

1. Remove the control valve cover.

When an error is detected, the display shows the letters “Err” with a number from 1 to 4. The table below lists Err numbers, a description of each error, the cause of the error and the solutions.

2. Press down on the top of the drive gear to disengage the cam gear. (See Step 1 in Start-Up Rinsing Procedure section.)

To clear the error from the display, press any button on the control. If the error still exists, the control will display the error message again after 30 seconds.

3. With the cam gear disengaged, rotate the cam gear counterclockwise to the various positions, using the same steps as the Start-Up Rinsing Procedure .

The control valve may also be operated in a fast mode for testing the control. To activate the fast mode, follow Steps 1 and 2 above to disengage the cam gear. When the cam gear is disengaged, it should be advanced slightly in a counterclockwise direction.

The switch will then activate the motor to cause the cam gear to advance through all the cycles in about 30 minutes. The control will not recognize a fast mode as a regeneration. Manual regenerations can be initiated only by pressing the manual regeneration switch on the face of the control.

Error Detection Codes

Code Description Cause Solution

Err 1 Electronics failure Control settings need reprogramming • Press any key to load default values. Refer to Programming the Control.

  • Err 2 Improper start of Valve cam gear has been manually
  • Press any key to clear the alarm. regeneration (limit switch rotated during a regeneration (Alarm automatically clears at “TIME OF open when it should be REGEN”). closed) Valve cam gear has been manually
  • The control will turn the motor on and drive rotated out of “service” position the cam gear to the proper location .

Faulty motor • Replace motor assembly.

Motor wire disconnected • Make sure motor wire is fully connected to control.

Faulty switch • Replace switch.

  • Err 3 Improper finish of Valve cam gear has been manually
  • The control will turn the motor on and regeneration (limit switch rotated out of “service” position drive the cam gear to the proper location. closed when it should be open) Faulty motor
  • Replace motor assembly.

Motor wire disconnected • Make sure motor wire is fully connected to control.

Faulty switch • Replace switch.

Err 4 Improper control settings One or more settings is out of the • See the Advanced Programming (one or more settings out allowable range Parameters section on page 22 and Default of the allowable range) Settings section on page 23.

Page 25 of the GE GNPR40L user manual — Troubleshooting Procedures
Page 25 · click to enlarge
Page 25

ge.com

Troubleshooting Procedures

  • Problem Possible Causes What To Do Capacity display stays Total system capacity was calculated
  • As the water usage continues, the remaining capacity will drop at “9999” even though to be a value greater than 9999 below 9999, then other values will be shown. there is water usage Control does not respond Button is not active in the
  • Wait for 30 seconds until lights begin to alternate. to REGEN button programming mode Control does not display Transformer is unplugged
  • Check connection to control and wall outlet. time of day No electric power at outlet
  • Repair outlet or use a working outlet. Defective transformer
  • Replace transformer. Defective circuit board
  • Replace control. Control does not display Outlet operated by a switch
  • Use an outlet not controlled by a switch. correct time of day Power outage
  • Reset time of day and replace battery. No water flow display Bypass valve in “bypass” position
  • Set bypass valve into “service” position. when water is flowing Meter probe disconnected or not fully
  • Fully insert probe into meter housing. (colon doesn’t blink) connected to meter housing Restricted meter turbine rotation due
  • Remove bypass valve, free up turbine and flush with clean to foreign material in meter water. Turbine should spin freely. If not, refer to the WaterMeter Maintenance section. Defective meter probe
  • Replace control. Defective circuit board
  • Replace control. Control display is frozen Back to back regenerations were
  • Refer to Manual Regeneration section. at REGEN TIME REMAINING requested Control regenerates at Power outages
  • Reset time of day to correct time of day and replace battery. the wrong time of day Time of day set incorrectly
  • Reset time of day to correct time of day. Note PM light. Time of regeneration set incorrectly
  • Reset time of regeneration. Note PM light. Cam gear stalled in Motor not operating
  • Replace motor assembly. regeneration cycle Motor runs backward
  • Replace motor assembly. No electric power at outlet
  • Repair outlet or use a working outlet. Broken gear
  • Replace gear. Defective switch
  • Replace switch. Binding of cam gear
  • Remove foreign object obstruction from valve discs or cam gear. Water pressure greater than 125 psi
  • Install pressure regulator to reduce pressure. during regeneration Defective circuit board
  • Replace control. Continuous regeneration. Defective switch
  • Replace switch. Cam gear does not stop at the end of regeneration. Control does not Transformer unplugged
  • Connect power. regenerate automatically No electric power at outlet
  • Repair outlet or use a working outlet. or when REGEN button is Defective motor
  • Replace motor assembly. pressed
  • Defective switch
  • Replace switch. Control does not If water flow display is not operative,
  • Refer to “No water flow display when water is flowing” regenerate automatically refer to “No water flow display in this table. but does regenerate when when water is flowing” in this table REGEN button is pressed Incorrect hardness and capacity
  • Set new control values. See the Programming the Control settings section. Defective circuit board
  • Replace control.
Page 26 of the GE GNPR40L user manual — Advanced Troubleshooting
Page 26 · click to enlarge
Page 26

Advanced troubleshooting.

  • Problem Possible Causes What To Do Run out of soft water Incorrect injector
  • With water pressure > 70 psi, use 4 bump injectors between regenerations (WS15X10059). Improper regeneration
  • Repeat regeneration, making certain correct salt dosage is used. Fouled resin bed
  • Use resin cleaner. Incorrect salt dose and capacity setting
  • Set Salt per Regen and Capacity setting to proper level. Refer to
  • the Programming the Control sections. Incorrect hardness
  • Set to correct hardness. Refer to the Programming the Control sections. Water hardness has increased
  • Set to new value. Refer to the Programming the Control sections. Restricted meter turbine rotation due
  • Remove bypass, free up turbine and flush with clean to foreign material in meter housing water. Turbine should spin freely—if not, replace meter. Water usage below 1/5 gallon
  • Repair leaky plumbing and/or fixtures. per minute Brine draw value from Advanced
  • Set correct brine draw value. Programming Parameters table is incorrect Incorrect salt type or use of grid plate
  • Do not use block salt or grid plate (salt shelf) in brine tank. (salt shelf) Control does not draw Low water pressure
  • Increase water pressure (20 psi at conditioner). brine Restricted drain line
  • Remove obstruction. Injector or injector screen is plugged
  • Clean injector and screen. Refer to the Cleaning the Injector and Screen section. Injector defective
  • Replace injector and cap. Valve disc 3 and/or 5 not closed
  • Manually operate cam gear to flush out foreign matter holding disc open. Replace if needed. Air check valve prematurely closed
  • Briefly put control into brine refill status. Refer to the Manual Regeneration section. Repair air check valve if needed. Brine tank overflow Brine valve disc 1 held open
  • Manually operate cam gear to flush out foreign matter holding disc open. Valve disc 2 not closed during brine
  • Manually operate cam gear to flush out foreign matter holding draw, causing brine refill disc open. Air leak in brine line to air check
  • Check all connections in brine line for leaks. Salt setting too high
  • Set in new values. Refer to Advanced Programming section. Float assembly malfunctions
  • Inspect float assembly in brine well for proper operation. It must be able to move freely. Intermittent or irregular Low water pressure
  • Increase water pressure (20 psi at conditioner). brine draw Defective injector
  • Replace both injector and injector cap. No conditioned water Unit did not regenerate
  • Check for power. after regeneration No salt in brine tank
  • Add salt to brine tank. Plugged injector
  • Remove injector and flush it and injector screen. Air check valve closed prematurely
  • Put control momentarily into REFILL to free air check. Replace or repair air check as needed. Incorrect salt type or use of grid plate
  • Do not use block salt or grid plate (salt shelf) in brine tank. (salt shelf) in brine tank Control backwashes at Incorrect backwash controller
  • Replace with correct size controller. excessively low or high Foreign matter affecting controller
  • Remove and clean controller. rate operation 26
Page 27 of the GE GNPR40L user manual — Advanced Troubleshooting
Page 27 · click to enlarge
Page 27

ge.com

  • Problem Possible Causes What To Do Flowing or dripping water Drain valve (2 or 6) or brine valve (1)
  • Manually operate cam gear to flush out foreign matter holding at drain line or brine line held open by foreign matter disc open. after regeneration Weak valve stem return spring on
  • Replace spring. top plate Resin in valve
  • Clean valve and backwash control. Hard water leakage Improper regeneration
  • Repeat regeneration, making sure the correct salt dosage is during service used. Leaking bypass valve
  • Replace bypass valve. O-ring around riser tube damaged
  • Replace O-ring. Incorrect salt type or use of grid plate
  • Do not use block salt or grid plate (salt shelf) in brine tank. (salt shelf) in brine tank
Page 28 of the GE GNPR40L user manual — Flow Diagrams
Page 28 · click to enlarge
Page 28

Flow diagrams.

GE GNPR40L — Flow Diagrams diagram (page 28)
Fig. 5 · Flow Diagrams

Valve No. Description Position 1 Brine Closed 2 Upper Drain Closed 3 Inlet Open 4 Bypass Closed 5 Outlet Open 6 Lower Drain Closed 7 Center Dist. Closed

Valve No. Description Position 1 Brine Open 2 Upper Drain Closed 3 Inlet Open 4 Bypass Closed 5 Outlet Open 6 Lower Drain Closed 7 Center Dist. Closed

GE GNPR40L — Flow Diagrams diagram (page 28)
Fig. 6 · Flow Diagrams
GE GNPR40L — Flow Diagrams diagram (page 28)
Fig. 7 · Flow Diagrams

Valve No. Description Position 1 Brine Open 2 Upper Drain Closed 3 Inlet Closed 4 Bypass Open 5 Outlet Closed 6 Lower Drain Closed 7 Center Dist. Open

Valve No. Description Position 1 Brine Open 2 Upper Drain Closed 3 Inlet Closed 4 Bypass Open 5 Outlet Closed 6 Lower Drain Closed 7 Center Dist. Open

Page 29 of the GE GNPR40L user manual — Flow Diagrams
Page 29 · click to enlarge
Page 29

ge.com

GE GNPR40L — Flow Diagrams diagram (page 29)
Fig. 8 · Flow Diagrams

Valve No. Description Position 1 Brine Closed 2 Upper Drain Open 3 Inlet Closed 4 Bypass Open 5 Outlet Open 6 Lower Drain Closed 7 Center Dist. Closed

Valve No. Description Position 1 Brine Closed 2 Upper Drain Closed 3 Inlet Open 4 Bypass Open 5 Outlet Closed 6 Lower Drain Open 7 Center Dist. Closed

Page 30 of the GE GNPR40L user manual — Checking the Brine Draw and Refill Function
Page 30 · click to enlarge
Page 30

Checking the brine draw and refill function.

1. Disconnect power to the control by unplugging the wall transformer or unplugging the power cord from the bottom of the control. 2. Press down on the top of the drive gear to disengage the cam gear. 3. With the cam gear disengaged, rotate the cam gear counterclockwise to the REFILL position until the air check fills with water, and water flows through the brine line into the brine tank. Do not run for more than three minutes. 4. Press down on the drive gear, and rotate the cam gear counterclockwise to the DRAW/RINSE position. Check that water is being drawn from the brine tank. The water level in the brine tank will recede very slowly. Observe the water level for at least one minute. If the water level does not recede, if it goes up or if air enters the transparent air check chamber and the ball falls and seats, refer to the Troubleshooting section in this manual. 5. When water is being drawn from the brine tank, press down on the drive gear and rotate the cam gear counterclockwise to just before the SERVICE position. Connect power to the control and allow the motor to drive the cam gear to the SERVICE position. The motor will stop. Run cold water from a nearby faucet until the water is clear and soft.

Water meter.

In rare instances, the turbine wheel of the water meter can collect small particles of oxidized iron, eventually preventing the wheel from turning. If the flow indicator light does not blink when conditioned water is flowing from the unit, it is an indication that the turbine wheel is not turning.

Turbine wheel Inner gland

5. Using a needle-nose pliers, remove the outer gland and the turbine wheel from the outlet of the valve. Generally, it will not be necessary to remove the inner gland. 6. Clean all iron deposits and/or debris off the turbine wheel. Excessive accumulation of iron may be removed from the components with a solution of sodium hydrosulfite (or sodium disulfite). Rinse the components thoroughly in clean water after using the iron removal solution. 7. Flush accumulated iron deposits and/or debris from the inside of the valve outlet. 8. Reinstall the turbine wheel into the outlet side of the valve, being certain that the turbine wheel shaft is carefully seated into the bearing of the inner gland. 9. Carefully reinstall the outer gland into the outlet side of the valve. Check turbine rotation. 10. Reconnect the water conditioner to the plumbing and follow Initial Start-Up section. 11. Open the downstream faucet (conditioned water) and check to be certain that the flow indicator (colon) is blinking.

1. Disconnect electrical power to the unit. 2. Shut off the water supply or put the bypass valve(s) into the BYPASS position. 3. Relieve resin tank pressure: A. Remove control valve cover. B. Press down on the top of the drive gear to disengage the

cam gear. C. With the cam gear disengaged, rotate the cam gear

counterclockwise to the BACKWASH position. Check that there is no water flow through the drain line before performing service or preventative maintenance. 4. Disconnect the water conditioner from the plumbing.

Air check · Outer gland · Turbine assembly

Page 31 of the GE GNPR40L user manual — Control valve diagram. ge.com
Page 31 · click to enlarge
Page 31

Control valve diagram. ge.com

GE GNPR40L — Control valve diagram. ge.com diagram (page 31)
Fig. 9 · Control valve diagram. ge.com
Page 32 of the GE GNPR40L user manual — Systems Diagram/Parts
Page 32 · click to enlarge
Page 32

Systems diagram.

GE GNPR40L — Systems Diagram/Parts diagram (page 32)
Fig. 10 · Systems Diagram/Parts
Page 34 of the GE GNPR40L user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 34 · click to enlarge
Page 34

GE Water Softening System Warranty. (For Customers in the United States)

All warranty service provided by our SmartWater™Authorized Servicer Network. To schedule service, call 800.952.5039 (U.S.) or 866.777.7627 (Canada). Please have serial number and model number available when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: We Will Replace:

One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.

Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase

Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered:

I Service trips to your home to teach you how to use

I Replacement of house fuses or resetting of circuit breakers.

the product.

I Damage to the product caused by accident, fire, floods or

I Improper installation, delivery or maintenance.

acts of God.

I Failure of the product if it is abused, misused, altered, used

I Incidental or consequential damage caused by possible

commercially or used for other than the intended purpose.

defects with this appliance, its installation or repair.

I Use of this product where water is microbiologically unsafe

I Product not accessible to provide required service.

or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 35 of the GE GNPR40L user manual — What Is Not Covered:
Page 35 · click to enlarge
Page 35

GE Water Softening System Warranty. (For Customers in Canada )

All warranty service provided by our Factory Service Centers or an authorized technician. For service, call toll free 1.866.777.7627. Please have serial number and model number available when calling for service.

For The Period Of: We Will Replace:

One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.

Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase

Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered:

I Service trips to your home to teach you how to use

I Replacement of house fuses or resetting of circuit breakers.

the product.

I Damage to the product caused by accident, fire, floods or

I Improper installation, delivery or maintenance.

acts of God.

I Failure of the product if it is abused, misused, altered, used

I Incidental or consequential damage caused by possible

commercially or used for other than the intended purpose.

defects with this appliance, its installation or repair.

I Use of this product where water is microbiologically unsafe

I Product not accessible to provide required service.

or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.

WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.

Warrantor: MABE CANADA INC.

Page 36 of the GE GNPR40L user manual — Consumer Support
Page 36 · click to enlarge
Page 36

Consumer Support.

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 11 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals or order parts online.

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 12 · Consumer Support

Expert GE repair service is only one step away from your door. Schedule your service at your convenience by calling 800.GE.CARES (800.432.2737) during normal business hours.

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 13 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 14 · Consumer Support

Purchase a GEextended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 15 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 16 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225

GE GNPR40L — Consumer Support diagram (page 36)
Fig. 17 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner’s Manual.

Printed in the United States

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE GNPR40L

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE GNPR40L

Be the first to ask — other owners or our team will answer.

Original document

GE GNPR40L manual PDF

36 pages·778 KB·Water System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…