managed ethernet switches


This manual describes how to install and use the D-GES7600 series EtherNav” Manageable 8/9-Port 10/100/1000 Base-TX (100/1000 Base-FX) Ethernet Switch. This switch integrates full wire speed switching technology with SNMP/RMON web-based management functions. The D-GES7600 series brings a simple answer to today’s complicated networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:





100FX Optical Ports Console Port

Front View (D-GES7600-MM-S shown)
When you unpack the product package, you shall find the items listed below.
Basic Features:
- Provides up to nine (10/100/1000 TX and/or100/1000 FX combination) ports - Multimode fiber using SC connectors up to 2 km; singlemode fiber using
SC connectors up to 15 km for 100FX, 10km for 1000FX
- Auto-negotiation for speed and duplicity on all TX ports
- Back-pressure and IEEE 802.3x compliant flow control
- Supports 4K MAC addresses
- Redundant power supply connections
- Optional TX or FX 1000Mbps aggregation port
- Optional contact closure for fiber loss alarm

PRODUCT FEATURES CONTINUED...
Management Support:
- 802.1Q tagged VLAN (up to 64 VLANs) - Quality of Service (QoS)
- Port-based Aggregation, up to four groups with a maximum
of four ports each group - Load sharing based on source and destination MAC addresses
- Port-mirroring provided through dedicated port, Port 1
Internet Working Protocols:
- 802.1D Spanning Tree - 802.1P/Q –GARP/GVRP
- IP Multicast Packet Filtering
Network Management Methods:
- Console port access via RS-232 cable - Telnet remote access
- SNMP Agent:

Optical Status 1000FX Port Status Power Indicator
(D-GES7600-MM-S Shown) · 10/100TX Port Status

This EtherNav” managed switch provides up to nine (10/100/1000TX and/or 100/1000FX combinations) ports:
- RJ-45 connectors - SC connector on fiber ports
- 10BaseT full-duplex mode - 10BaseT half-duplex mode - 100BaseTX full-duplex mode - 100BaseTX half-duplex mode - 100BaseFX full-duplex mode - 100BaseFX half-duplex mode - 1000BaseTX full-duplex mode - 1000BaseTX half-duplex mode - 1000BaseFX full-duplex mode - 1000BaseFX half-duplex mode - Auto-sensing mode except 100FX

I. Half-duplex mode uses back pressure flow control to prevent the receiving buffer from being overrun by data from a source node.
II. Full-duplex mode uses 802.3x flow control standard to prevent fast data traffic from overrunning slow data traffic.
III. Auto-sensing mode is in use after auto-negotiating with the other end of the link.
In general, the D-GES7600 is responsible for switching both VLAN tagged and untagged frames from a receiving port to one or more transmitting ports. The switch performs multiple steps during the switching process:
LEARNING
FILTERING
AGING
Below is additional information about tasks that the switch performs during unicast and multicast switching.
VLAN CLASSIFICATION When the switch receives a frame, it classifies the frame in one of two ways:
- If the frame is untagged, the switch classifies the frame to an
associated VLAN.
- If the frame is tagged, the switch uses the tagged VLAN ID to identify the
broadcasting domain of the frame.

I. Half-duplex mode uses back pressure flow control to prevent the receiving buffer from being overrun by data from a source node.
II. Full-duplex mode uses 802.3x flow control standard to prevent fast data traffic from overrunning slow data traffic.
III. Auto-sensing mode is in use after auto-negotiating with the other end of the link.
LEARNING After VLAN classification, the switch checks the pair in the switching database (SDB) to see whether the pair is known.
- If it is unknown, the switch inserts the into the SDB and learns the .
- If it is known, the switch checks the for a mis matched port ID. If the port ID associated with the pair in the SDB is different than the receiving port, the switch modifies the port ID in the SDB and modifies its management database (MDB) accordingly.
FILTERING After learning the address, the switch checks:
- Whether the source port or destination port is in the forwarding state.
- Whether the source MAC address or destination MAC address is to be filtered.
- Whether the source port ID is the same as destination port ID.
If any of these conditions are met, the switch drops the receiving. Otherwise, it continues with the forwarding process described below.
FORWARDING During the forwarding process, the switch checks whether the pair is unknown.
- If it is unknown, the switch floods the receiving frame to all ports in the VLAN,
excluding the source port.
- If it is known, the switch forwards the receiving frame to the port associated
with the pair. At the same time, the switch ascertains the individual’s ports VLAN tagging and/or un-tagging configuration and corresponding VLAN ID render the appropriate frame tagging when the frame is ready to be transmitted.

For multicast switching, the D-GES7600 checks whether the received frame is a BPDU. If a BPDU is received, the switch forwards the frame to the CPU for processing by the spanning tree protocol. Otherwise, the D-GES7600 performs the following processes:
VLAN CLASSIFICATION Same as for unicast switching.
LEARNING Same as for unicast switching.
FILTERING After learning the address, the switch checks:
- Whether the source port or destination port is not in the following state.
- Whether the source MAC address or destination MAC address is to be filtered.
If any of these conditions are met, the switch drops the receiving. Otherwise, it continues with the forwarding process described below.
FORWARDING The D-GES7600 floods the received multicast frame to all ports that are in the forwarding state within the VLAN, excluding the source port. At the same time, the switch ascertains the individual ports VLAN tagging/untagging configuration and corresponding VLAN to render the appropriate frame tagging when the frame is ready to be transmitted.
AGING The switch performs the aging process for the pair in the switching database. Once a pair is aged out, the SBD is modified.
SPANNING TREE The D-GES7600 supports one Spanning Tree per bridged network.

A virtual LAN (VLAN) is a network of computers or peripherals that behave as if they are connected to the same wire, even though they may actually be physically located in different locations of a LAN. VLANs are similar to a group of end stations, perhaps on multiple physical LAN segments that are not inhibited by their physical location and can communicate as if they were on a common LAN.
VLANs are configured through software rather than hardware, which makes the extremely flexible. One of the biggest advantages of VLANs is that when a peripheral is physically moved to another location, it can stay on the same VLAN without any hardware reconfiguration.
Because VLANs are not limited by the hardware constraints that physically connect traditional LAN segments to a network, they can define a network into various logical configurations. For example, VLANs can define a network by function.
In this setting, a system integrator might create one VLAN for multimedia users and another for email users. VLANs can also define a network by location or type of service. For example, a location might have one VLAN for its cameras, another for it access control, and another for its roadside signs.
VLANs can also be set up according to the organization structure within a company. For example, the company president might have his/her own VLAN, the executive staff might have a different VLAN, and the remaining employees might have yet another different VLAN.
As these examples show, VLANs offer matchless flexibility. The following sections describe how deploying VLANs can benefit system integrators and reduce design costs.

BROADCAST CONTROL In traditional networks, traffic broadcasts to all network devices, whether they are the intended recipients or not. However, VLANs can be set up to contain only those devices that need to communicate with each other. As a result, VLANs considerably reduce network congestion. In addition, VLANs prevent broadcast storms from causing a network from crashing due to volumes of traffic.
MULTICAST-BASED MULTIMEDIA APPLICATIONS Multimedia applications, such as interactive training, video monitoring, and video/data transmissions, require large amounts of bandwidth. These applications are also extremely sensitive to variable delays, which are inevitable on a shared Ethernet network. By defining a VLAN based on the IP multicast address for all defined members on the VLAN, adequate bandwidth will be available for these applications, providing true multimedia Ethernet.
IMPROVED SECURITY Because VLANs are independent, only the devices within the same VLAN can communicate with each other. If a device in one VLAN wants to communicate with a device in another VLAN, the traffic must go through a router.
VLAN MEMBERSHIP VLAN implementation allows:
- Up to 64 VLANs in one switch.
- VLANs across multiple switches by using explicit or implicit tagging and the
GARP/GVRP protocol defined in IEEE802.1p and 802.1Q.
- An end station’s network interface card belongs to multiple VLANs.
-A switch port to be associated with multiple VLANs.
DEFINITIONS OF VLAN MEMBERSHIP VLAN implementation allows VLAN membership to be defined based on ports. Physical port numbers organizes port-based VLANs. For example, switch ports 1,2,4 and 6 can be grouped on VLAN, while server ports 3, 5, 7 and 8 can be on another VLAN. Broadcasts from servers within each group would only go to the members of its own VLAN. This ensures that broadcast storms cannot cause a network to crash due to volumes of traffic.
VLAN MEMBERSHIP LEARNING Port-based VLAN is defined using a static binding between a VLAN and its associated ports. The switch’s forwarding decision is based on the destination MAC address and its associated port ID. Therefore, to make valid forwarding and flooding decisions, the switch learns the relationship of the MAC address to its related port…and thus to the VLAN…at runtime.

REMOTE VLAN MEMBERSHIP Additionally to providing network management tools that allow network administrators to statically add and delete VLAN member ports, the switch also supports GVRP (GARP VLAN Registration Protocol). GVRP allows for dynamic registration of VLAN port members within switch and across multiple switches.
Other than supporting dynamic updating of registration entries in a switch, GVRP is used to communicate VLAN registration information to other VLAN-aware switches, so that a VLAN member can cover a wide span of switches on a network.
GVRP allows both VLAN-aware workstations and switches to issue and revoke VLAN memberships. VLAN-aware switches register a propagate VLAN membership to all ports that belong to the active topology of the VLAN.
VLAN CONFIGURATION The switch provides a Local/Remote Management Console Interface for VLAN configuration and management. An SNMP-based VLAN MIB is also provided.
INTRA-VLAN COMMUNICATION The switch supports intra-VLAN communication through hardware as described in "Basic Functions" section.
INTER-VLAN COMMUNICATION The switch supports Inter-VLAN communication using CPU-based routing software.
In addition to network management tools that allow network administrators to statically add and delete VLAN member ports, the routing switch supports GARP VLAN Registration Protocol (GVRP). GVRP supports dynamic registration of VLAN port members within a switch and across multiple switches.
In addition to dynamically updating registration entries with a switch, GVRP is used to communicate VLAN registration information to other VLAN-aware switches, so that members of a VLAN can cover a wide span of switches on a network.
GVRP allows both VLAN-aware workstations and switches to issue and revoke VLAN memberships. VLAN-aware switches register and propagate VLAN membership to all ports that are part of the active topology of the VLAN.
The Internet Group Management Protocol (IGMP) runs between hosts and their immediately neighboring multicast routers. The protocol’s mechanisms allow a host to inform its local router that it wants to receive transmissions addressed to a specific multicast group.
Routers periodically query the LAN to determine if known group members are still active.

IGMP Snooping & IP Multicast Filtering Continued...
If there is more than one router on the LAN performing IP multicasting, one of the routers is elected ‘querier’ and assumes the reponsibility.
Based on the group membership information learned from the IGMP, a router can determine which (if any) multicast traffic needs to be forwarded to each of its ‘leaf’ sub-networks. Multicast routers use this information, along with a multicast routing protocol, to support IP multicasting across the Internet.
Routing switches support IP Multicast Filtering by:
- Passively snooping on the IGMP Query and IGMP Report packets transferred
between IP Multicast Routers and IP Multicast host groups to learn about IP Multicast group members, and
- Actively sending IGMP Query messages to solicit IP Multicast group members.
The purpose of IP multicast filtering is to optimize a switched network’s performance, so multicast packets will only be forwarded to those ports containing multicast group hosts members and routers instead of flooding to all ports in the subnet (VLAN).
Routing switches with IP multicast filtering/switching capability not only run passively monitor IGMP Query and Report messages, DVMRP Probe messages, PIM, and MOSPF Hello messages; they also actively send IGMP Query messages to learn locations of multicast routers and member hosts in multicast groups within each VLAN.
Administration Console Via RS-232 Console Port: The switch provides an on board serial port, which allows the switch to be configured via a directly connected terminal or a Telnet session.
Web-Based Browser Interface: The switch also boasts a point-and-click browser-based interface that lets users access full switch configuration and functionality from a Netscape or Internet Explorer browser.
External SNMP-Based Network Management: The switch can also be configured via SNMP. For more information on switch management, please refer to the "Switch Management" section.

This section gives step-by-step instructions about how to install the EtherNav” D-GES7600 switch:
Selecting a Site for the Switch As with any electric device, you should place the switch where it will not be subjected to temperatures, humidity, or electromagnetic interference above the rated specifications. The site you select should meet the following requirements:
- The ambient temperature should be between –40 to 74 degrees Celsius.
- The relative humidity should be less than 95 percent, non-condensing.
- Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards for EIC 801-3, Level 2 (3V/M) field strength.
- Make sure that the switch receives adequate ventilation. Avoid blocking the
ventilation holes on all sides of the switch.
Methods for Mounting the D-GES7600 Several mounting configurations are available for the variety of applications for which this switch was designed. Each configuration is described as follows:
Wall or Floor Mounting (-W Option) The brackets provided will require the removal and re-installation of the cover screws as shown below.

Bracket (-W Option) · Cover Screws

DIN Rail Back Mounting (-DB Option) The bracket provided will require the removal and re-installation of some cover screws as shown below.

DIN Rail Side Mounting (-DS Option) The bracket provided will require the removal and re-installation of one cover screw, the other screws are provided with the bracket as shown below.

D-GES7600 Unit (10/100 Port Side)

Rack Mounting Single Unit (-RS Option) The brackets provided have screws included for proper mounting as shown below.

Mounting Screws 4 Locations (Provided)

Brackets (-RS Option) · (Top View) · (Front View)

Rack Mounting Dual Units (-RD Option) The brackets and braces provided have screws included for proper mounting as shown below.

Brace (2 Provided )


Step One: Wire the supplied AC power adapter to the “A” receptacle plug at the front of the switch. — white stripe to pin 1 (+), black to pin 2 (-).
Step Two: Attach the plug into a standard AC outlet with the appropriate AC voltage.
Secondary “B” Power Connector Primary “A” Power Connector

To Primary Wall Supply To Secondary Supply
Power-On Self Test (POST) The switch performs its Power-On Self Test (POST) when the power is applied to the switch. During the POST, the switch CPU will:
- Perform a series of diagnostic procedures to make sure the
basic system is functioning properly - Decompresses the main switching software runtime image from
the flash ROM into the DRAM area
External Power · (D7600-MM-E-CC Shown))

Cable Type & Length
Wire the supplied AC power adapter to the “A” receptacle plug at the front of the switch. — white stripe to pin 1 (+), black to pin 2 (-).
Step Two: Attach the plug into a standard AC outlet with the appropriate AC voltage.
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Speed Connector Port Speed
Cable Max. Distance
10BaseT RJ-45 100 m 10/20 Mbps 2-Pair UTP/STP Cat. 5, 5E, 6
10BaseTX 1000BaseTX RJ-45 100 m 100/200 Mbps 2-Pair UTP/STP Cat. 5, 5E, 6
100BaseFX SC 2 km 100/200 Mbps MMF (50 or 62.5µm) -25dB Return Loss Minimum
100/200 Mbps SMF (9 or 10µm) -25dB Return Loss Minimum
1000BaseFX SC 28 km 500/1000 Mbps SMF (9 or 10µm) -25dB Return Loss Minimum
Cabling: Step 1: First, ensure the power of the switch and end devices are turned off. NOTE: Always ensure that the power is off before any installation.

This section explains the methods that you can use to configure management access to the switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (workstation or personal computer) and the system. It also contains information about port connection options.
This section covers the following topics:
MANAGEMENT ACCESS OVERVIEW The EtherNav” D-GES7600 switch gives you the flexibility to access and manage the switch using any or all of the following methods.
The administration console and web browser interface support are embedded in the switch and are available for immediate use.

Administration Console via RS-232 Console Port:
Advantages:
- No IP address or subnet needed - Text-based - HyperTerminal built into Windows 95/98/NT/2000
Disadvantages:
- Must be near switch - Inconvenient for remote users
Web-Based Browser Interface:
Advantages:
- Ideal for configuring the switch remotely - Compatible with all popular browsers - Can be accessed from any location - Most visually appealing
Disadvantages:
- Security can be compromised (hackers need only know the IP address
and subnet mask) - May encounter lag times on poor connections
Telnet Interface:
The connection is the same as Web-Based Browser Interface, but with Console Port Hyper Terminal type user interface.
External SNMP-Based Network Management Application:
Disadvantages: - Requires SNMP manager software - Least visually appealing of all three methods - Some settings require calculations - Security can be compromised (hackers need only know the community name)
operating systems

ADMINISTRATION CONSOLE The administration console is an external, character-oriented, menu-driven user interface for performing system administration such as displaying statistics or changing option settings.
Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch’s console port.
There are two ways to use this management method: direct access or mode Telnet access. The following sections describe these methods:
DIRECT ACCESS Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as Hyper-Terminal) to the switch console port.
When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):
[Default Parameters] 115, 200bps 8 Data Bits No Parity 1 Stop Bit Flow Control None
This management method is often preferred because you can remain connected and monitor the system during systems reboots. Also certain error messages are sent to the Console port regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.
Telnet ACCESS You can access the switch’s administration console from a PC or Macintosh using DOS window through network with IP address. The switch management program provides a CONSOLE PORT screen, accessible from the BASIC MANAGEMENT screen, that lets you configure parameters for remote access.

WEB MANAGEMENT The switch provides a browser interface that lets you configure and manage the switch remotely.
After you set up your IP address for the switch, you can access the switch’s web interface applications directly in your web browser by entering the IP address of the switch. You can then use your web browser to list and manage switch configuration parameters from one central location, just as if you were directly connected to the switch’s console port.
Web Management requires either Microsoft Internet Explorer 4.01 or later or Netscape Navigator 4.03 or later.
http://help.netscape.com/filelib.html#smartupdate
If you encounter problems accessing Help files when you use Netscape, clear the browser memory cache and disk cache, and restart the browser.
http://www.microsoft.com/msdownload/iebuild/ie4sp1_win32/en/ie4sp1_win3
If the above link is unavailable, download the service pack from the Microsoft home page:

If you enable the SNMP function through the console port, you can use an external SNMP- based application to configure and manage the switch. This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string. This management method, in fact, uses two community strings: the ‘get’ community string and the ‘set’ community string. If the SNMP Network manage- ment station only knows the ‘set’ community string, it can read and write to the MIBs. However, if it only knows the ‘get’ community string, it can only read MIBs. The default getting and setting community strings for the switch are public.
PROTOCOLS The switch support the following protocols:
- Virtual Terminal Protocols, such as Telnet A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.
Simple Network Management Protocol (SNMP) SNMP is the standard management protocol for multi-vendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service.
Management Architecture All of the management application modules use the same Messaging Application Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (e.g. console port) are immediately displayed as the other management methods (e.g. SNMP agent of web browser).
The management architecture of the switch adheres to the IEEE open standard. This compliance assures customers that the switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.

The switch provides a menu-driven console interface for configuration purposes. The switch can be configured either locally through its RS-232 port or remotely via a Telnet session.
This section describes how to configure the switch using its menu-driven console.
Logging On To The Switch At the screen prompt:
Switch Console Login: Password: Login Name Enter the console interface factory default console name admin.
Password Enter the factory default password (ethernav, press <Enter> directly). Or enter a user-defined password if you followed the instructions later and changed the factory default password.
Factory Default Password: ethernav, press <Enter> directly.



Basic Management Refer to performing basic management activities.
Advanced Management Refer to performing advanced management activities.
Logout Highlight this option and press <enter> to log out.
Save Settings Highlight this option and press <enter> to save the current settings and remain in the configuration program.
Restore Default Settings Highlight this option and press <enter> to restore the factory default settings.
Reboot Highlight this option and press <enter> to reboot.

Navigating Through the Console Interface The console interface consists of a series of menu boxes. Each menu box has several options, which are listed vertically. Move the highlight to select an option as you wish, press the key to activate that option.
Press this key…. To
Up Arrow or “K” Move the highlight one line up in a menu box
Down Arrow or “J” Move the highlight one line down in a menu box
Tab Move the highlight between screens
Enter Select the highlighted option
Esc Move to a previous menu
Basic management activities consist of General, LAN Port, and Console Port tasks.
To Perform Basic Management Activities








LAN Port Configurations







Console Port Configurations




Alarm Configurations

Advanced management activities consist of L2 Switching Database/ IP Networking/ Bridging/ Static Filtering/ Spanning Tree/ SNMP/ Other Protocols/ Port Trunking/ Port Mirroring/ File Transfer.
To Perform Advanced Management Activities

L2 Switching DataBase View and change VLAN, MAC address, IP multicast group, and port perspectives.
IP Networking View and change IP settings and ping settings.
Bridging View and change aging period for MAC address and flood limit for all ports.
Static Filtering View/add/delete/search all source/destination MAC addresses to be filtered.
Rapid Spanning Tree View and change spanning tree configurations, ports states, path costs, and port priorities.
SNMP View and change the SNMP configuration.
Port Mirroring Mirror one port to Port 1.
Other Protocols View and change GVRP and IGMP settings.
Link Aggregation Assign a range of ports to trunking groups.
File Transfer Send files using the TFTP or Kermit protocol.
QoS Set Up



L2 Switching DataBase




IP Multicast Group Perspective





MAC Address Perspective · Port Perspective










IP Networking


ARP Table Step 1: Highlight ARP Table from IP Networking, and press <enter>.

Routing Table Step 1: Highlight Routing Table from IP Networking, and press <enter>.


DHCP Gateway Step 1: Highlight DHCP Gateway from IP Networking, and press <enter>.



Ping Settings




Bridging · Static Filtering



MAC Address in Filters

Source Filter · Destination Filter

MAC Address in Filters


Rapid Spanning Tree Functions



Spanning Tree Port States

Spanning Tree Path Costs


Spanning Tree Port Priorities


Protocol Migration




Edge Port · Point-to-Point Link · SNMP Functions




Other Protocols · Link Aggregation



Aggregation Port Status




Actor Screen · Partner Screen · Aggregation Port Settings




Aggregation Port Settings · Aggregation Port Statistics


IEEE802.3 Aggregation


Fast Link Aggregation




Port Mirroring

Quality of Service (QoS)


Global Setting




Logical Port


VLAN Step 1: Move to highlight VLAN from QoS Setup, and press <enter>. Step 2: Assign desired port to a VLAN.

ToS Step 1: Move to highlight ToS from QoS Setup, and press <enter>. Step 2: Highlight desired port to be set.


Tx Queue Setting Step 1: Move to highlight Tx Queue Setting from QoS Setup, and press <enter>. Step 2: Set Queue for optional Port 9.



Fixed Priority · Rate Control

The TFTP protocol is used to download upgraded software to the switch.
A VLAN with the proper IP address and routing path to the TFTP server must be configured for the switch to access the specified TFTP server.






To log out, highlight Logout from [Switch Management] screen, and press <enter>. Please remember to save settings you have changed before you log out.
To save the current settings and remain in the configuration program, highlight Save Settings from [Switch Management], and press <enter>.
To restore the factory default settings, highlight Restore Default Settings from [Switch Management], and press <enter>.
The switch will be rebooted after confirming <Yes> as to restore the default settings.
To reboot the switch, highlight Reboot from [Switch Management], and press <enter>.

The EtherNav” D7600 switch provides a web-based browser interface for configuring and manag- ing the switch. This interface allows you to access the switch using a preferred web browser.
This section describes how to configure the switch using its web-based browser interface.
In your web browser, specify the IP address of the switch.
Login ID Enter the factory default login ID: admin.
Password Enter the factory default password (ethernav, click <Login>).

Switch IP Address

The web browser interface provides three point-and-click buttons at the upper field of the screen for configuring and managing the D-GES7600.
The Basic Setup/General parameters appear at the lower field of the screen. These parameters can also be displayed by clicking Basic Setup button and select General in sub-menu.

File Save settings configured in the browser interface / download upgraded software via TFTP / reboot the switch / logout of the browser interface.
Basic Setup Perform general, LAN port, and console port activities.
Advanced Setup Perform MAC address management / IP networking / per port statistics / port priority / bridging / static MAC filters / IP multicast group / VLAN perspective / spanning tree perspective / SNMP / other protocols / port trunking / port mirroring.

To Perform File Activities: Click the [File] button at the upper field of the main display, the menu options appear.


To perform Basic Setup Activities: Click the [Basic Setup] button at the upper field of the main display, the menu options appear.




LAN Port Configuration





Enable: places the port in UP state. In this state, packets can be switched to and from the port.


Console Port Configuration

To Perform Advanced Setup Activities: Click the [Advanced Setup] button at the upper field of the main display, the menu options appear.


MAC Address Management


To access the IP networking parameters, click the Advanced Setup button, and Point to IP Networking from the selection menu.

IP Networking


* No precautionary message appears before you delete the IP address. * Be sure you want to delete it before doing so. * The IP address is not deleted until you click Update Setting.

Per Port Statistics · Port Priority · Bridging


To access the static MAC filter parameters, click the Advanced Setup button, and point to Static MAC Filter in the selection menu.

Static MAC Filter

To view the IP multicast group addresses, click the Advanced Setup button, and click IP Multicast Group in the selection menu. The information is read-only.
To view the VLAN configuration information, click the Advanced Setup button, and point to VLAN Perspective in the selection menu.
IP Multicast Group · VLAN Perspective

To view the IP multicast group addresses, click the Advanced Setup button, and click IP Multicast Group in the selection menu. The information is read-only.
To view the VLAN configuration information, click the Advanced Setup button, and point to VLAN Perspective in the selection menu.


IP Multicast Group · VLAN Perspective

To view the IP multicast group addresses, click the Advanced Setup button, and click IP Multicast Group in the selection menu. The information is read-only.
To view the VLAN configuration information, click the Advanced Setup button, and point to VLAN Perspective in the selection menu.
IP Multicast Group · VLAN Perspective

To view the spanning tree perspective parameters, click the Advanced Setup button, and point to Link Aggregation in the selection menu.


Link Aggregation




To view and/or change all SNMP-related information, click the Advanced Setup button, and click SNMP in the selection menu. The SNMP Configurations window appears. As shown below, the factory-default SNMP value is enabled and the factory-default Community Name value is public.


To enable or disable the GVRP and/or IGMP protocols, click the Advanced Setup button, and click Other Protocols in the selection menu.
Other Protocols

To use the switch’s mirroring capability to mirror one port to Port 1, click the Advanced Setup button, and click Port Mirroring in the selection menu. Click Port 1 in the Mirror To column.

Port Mirroring

This section describes the switch’s Simple Network Management Protocol (SNMP) and Remote Monitoring (RMON) capabilities.
RMON is an abbreviation for the Remote Monitoring MIB (Management Information Base). RMON is a system defined by the Internet Engineering Task Force (IETF) document RFC 1757, which defines how networks can be monitored remotely.
RMONs typically consist of two components: an RMON probe and a management workstation:
- The RMON probe is an intelligent device or software agent that continually
collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a management workstation on request or when a pre-defined threshold is reached.
- The management workstation collects the statistics that the RMON probe
gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.
The switch provides RMON capabilities that allow network administrators to set parameters and view statistical counters defined in MIB-II, Bridge MIB, and RMON MIB. RMON activities are performed at a Network Management Station running an SNMP network management application with graphical user interface.
The SNMP Agent running on the switch manager CPU is responsible for:
- Retrieving MIB counters from various layers of software modules according to the
SNMP GET/GET NEXT frame messages.
- Setting MIB variables according to the SNMP SET frame message.
- Generating an SNMP TRAP frame message to the Network Management Station if the
threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:

Warm start Cold start Link up Link down Authentication failure Rising alarm Falling alarm Topology alarm
MIB-2 defines a set of manageable objects in various layers of the TCP/IP protocol suites. MIB-2 covers all manageable objects from layer 1 to layer 4 and, as a result, is the major SNMP MIB supported by all vendors in the networking industry. The switch supports a complete implementation of SNMP Agent and MIB-2.
The switch provides hardware-based RMON counters in the switch chipset. The switch manager CPU polls these counters periodically to collect the statistics in a format that complies with the RMON MIB definition.
RMON Groups Supported The switch supports the following RMON MIB groups defined in RFC 1757:
- RMON Statistics Group – maintains utilization and error statistics for the
switch port being monitored.
- RMON History Group – gathers and stores periodic statistical samples
from the previous Statistics Group.
- RMON Alarm Group – allows a network administrator to define alarm thresholds for
any MIB variable. An alarm can be associated with Low Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a threshold, falls below a threshold, or exceeds or falls below a threshold.
RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.

The switch supports the following four groups of Bridge MIB (RFC 1493):
- The dot1dBase Group – a mandatory group that contains the objects applicable to
all types of bridges.
- The dot1dStp Group – contains objects that denote the bridge’s state with respect to the
Spanning Tree Protocol. If a node does not implement the Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only, source route, or SRT bridge that implements the Spanning Tree Protocol.
- The dot1dTp Group – contains objects that describe the entity’s transparent bridging status.
This group is applicable to transparent operation only and SRT bridges.
- The dot1dStatic Group – contains objects that describe the entity’s destination-address
filtering status. This group is applicable to any type of bridge which performs destination- address filtering.
Bridge Groups Supported

Manageable 8/9-Port Switch 10/100/1000BaseT/TX auto-negotiating ports with RJ-45 connectors and 100/1000BaseFX fiber ports combination
Applicable Standards IEEE 802.3 10BaseT IEEE 802.3u, ab 100/1000BaseTX/FX
10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex 1000/2000Mbps half/ full-duplex
Performance 148,80pps for 10Mbps 148,800pps for 100Mbps 1,488,000pps for 1000Mbps
2-pair UTP/STP Cat. 5, 5E, 6 2-pair UTP/STP Cat. 5E Both up to 100m (328ft) MMF (50 or 62.5_m), SMF (9 or10_m)
LED Indicators Per unit – Power status Per port – LNK (Link) /ACT (Activity) FDX/COL
Dimensions W 8.5 in _ D 7.5 in _ H 1.75 in
Net Weight 4.5 lbs. Approx.
Power Input External power adapter 12-24V DC; 1A
Power Consumption 12W max.
Operating Temperature -40°C to 74° C
Storage Temperature -40°C to 85° C
Emissions FCC part 15 Class A, NEMA TS2, UL, CE Mark Class A
Switching Method Store-and-Forward · Humidity 0%-95% non-condensing

Pin arrangement of RJ-45 connectors:
The following table lists the pin out of 10/100/1000BaseT/TX ports.
Pin Regular Ports Uplink Port
Input Receive Data + Output Transmit Data +
Input Receive Data - Output Transmit Data -
Output Transmit Data + Input Receive Data +
5 NC NC
6 Output Transmit Data - Input Receive Data -
8 NC NC

a. GE Security warrants that its products are free from defects in workmanship and materials, and will conform to GE Security’s published specifications, subject to the terms of this limited warran- ty. With respect to any product furnished by GE Security, the foregoing shall apply only to failures to meet said warranty that appear within the applicable warranty period set forth in the Security Equipment Return and Warranty Policy Statement on our website. The warranty extends only to Buyer and does not extend to any other party. GE Security is not responsible for conditions or applications over which GE Security has no control. Defects or problems as a result of such conditions or applications are not the responsibility of GE Security. Such conditions include nor- mal wear and tear; catastrophe; fault or negligence of the user or a party other than GE Security; improper installation, application, storage, maintenance, or use of products; other causes external to products;or failure to conform to any applicable recommendations of GE Security. The warran- ty does not cover, and GE Security does not warrant, batteries of any type used in connection with other products furnished. To the extent that any product includes software or firmware, whether included in a product furnished hereunder or provided separately, GE Security warrants that such software/firmware will, at the time of delivery by GE security, conform in all material respects to GE Security’s documentation relating to such software/firmware.
b. If any product fails to meet the limited warranty, GE Security shall, at its option, correct any such failure by repairing any defective or damaged parts of damaged product, or make available, FOB shipping point, any necessary repaired or replacement parts. GE Security reserves the right to replace any product under warranty with new or remanufactured product. GE Security will not be responsible for labor costs of removal or reinstallation of products. The repaired or replaced product is then warranted under the terms of the limited warranty for the balance of the term of the warranty or for 90 days, whichever is longer. For any warranty claim, Buyer should contact Customer Service and request authorization to return the product.
c. The preceding subsections of this limited warranty set forth the exclusive remedies for claims based on any defect, failure, malfunction, or any other performance or nonperformance of any product, whether the claim is in contract, indemnity, warranty, tort (including negligence), strict liability or otherwise, and however instituted. Upon expiration of the applicable limited warranty period, any liability of GE security in connection with such exclusive remedies shall terminate, and Buyer shall have 30 days after the warranty period to give written notice of any defects, failures, malfunctions, or other performance or nonperformance issue that appeared during the warranty period. Except as set forth in the section entitled Patents, the foregoing limited warranty is exclusive and in lieu of all other warranties, whether written, oral, implied, or statutory. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.
Customer Support For assistance in installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, please contact technical support during normal business hours (Monday through Friday, excluding holidays, between 6 a.m. and 5 p.m. Pacific Time).
GE Security Call: 888 437-3287 (US, including Alaska and Hawaii; Puerto Rico; Canada) Outside the toll-free area: 503 885-5700 Fax: 561 998-6224 www.gesecurity.com
Canada T 519-376-2430 F 519-376-7258
Australia T 61-3-9239-1200 F 61-3-9239-1299
Latin America T 305-593-4301 F 305-593-4300
888 (437-3287) F 561 998-6224 E rs-bctinfo@gesecurity.com
Asia T 852-2907-8108 F 852-2142-5063
Europe T 44-113-238-1668 F 44-113-253-8121
As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications visit GE Security online at www.GESecurity.com or contact your GE Sales Representative.
Copyright © 2006 General Electric Company. All rights reserved.
D-GES7600 Released 06-OCTOBER-06
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.