

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
USE OF EXTENSION CORDS– 115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
DO NOT use an extension cord with any of the 230/208 volt models.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
FAN
R
E
O
O
HI COOL
MED COOL
MODE CONTROL TEMP CONTROL
Controls
Mode Control
Temp Control
HI COOL, MED COOL and LOW COOL provide cooling with different fan speeds.
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
LOW FAN or HI FAN provides air circulation and filtering without cooling.
Cooling Descriptions For Normal Cooling—Select HI COOL or MED COOL with the temp control at 5 or 6.
For Maximum Cooling—Select HI COOL with the temp control at 10.
For Quieter & Nighttime Cooling— Select LOW COOL with the temp control at 3 or 4.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
About the controls on the air conditioner.
Additional controls and important information.
When set at CLOSED, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside. OPEN CLOSED
The air direction tabs are located at the top on either side of the front grille. The tabs let you control the air to the left, right or straight ahead.
To adjust it up or down, move the bank of louvers.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.
The air filter behind the inlet grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove the inlet grille and the air filter:
Grasp both sides near the top of the inlet grille and pull forward. The inlet grille will pivot forward to reveal the air filter.
Unhook the filter from the tabs.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
Replace the inlet grille.
Air filter · Tabs · Inlet grille

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Preparing to install the air conditioner.
Read these instructions completely and carefully.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
For personal safety, this air conditioner must be properly grounded.
It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
Follow National Electric Codes (NEC) and/or local codes and ordinances.
Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
I Ruler or tape measure
I Scissors or knife
I Drill and 1/8″ bit
I Flat-blade screwdriver · I Pencil · I Level


Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Horizontal sliding window installation instructions.
Read completely, then follow step-by-step.
IThese instructions are for a horizontal sliding
IFor installation in a casement window, the
or a casement window. IThe electrical outlet must be within reach of the
window frame assembly and the side of the building must be adequate to support the weight of the air conditioner.
power cord.
21″ min. 40 1⁄2″ max.
211/2″ min.
151⁄2″ min.
153/4″ min. 171/2″ max.
Casement window (See Casement Window Installation Instructions)
Attach the support platform to the sill plate with 3 type C screws. Loosely attach the support angle to the bottom of the support platform using 2 type A screws with washers and nuts.
Attach the leveling bolt and nut.
NOTE: To overcome interference of the support platform with the window track or storm window, securely attach a 2″ wide shim strip to the window sill. This strip should be as long as the width of the support platform and flush with the back edge of the sill. The thickness of the strip should be controlled by the amount of interference.
3 type C screws
Pull the support angle against the outside wall and tighten the screws on top of the support platform. Adjust the leveling bolt so the support platform is level. This will allow the air conditioner to tilt slightly for proper drainage. Tighten the nut.
Leveling bolt and nut
Place the sill plate against the lower window track and firmly against the vertical side edge of the window frame. Attach the sill plate to the window stool using 2 type B screws.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Cut two pieces of adhesive back foam seal to the height of the window opening. Remove the backing and apply to the vertical inside edges of the window frame and the sliding window that will rest against the air conditioner. Cut one piece to the width of the window opening and apply to the top inside edge of the window frame.
Drill two 1/8″ holes in the window channel frame through the existing holes in the bottom bar. Screw 2 type C screws through these holes.
Adhesive back foam seal
4 5 6 7 8
LOW COOL HI COOL MED COOL
NOTES:
IIf the air conditioner does not fit securely, remove it and
readjust the leveling bolt.
IMake sure the air conditioner is firmly anchored to the
window channel frame.
Slide the air conditioner onto the support platform. Be sure the side channel butts against the vertical side edge of the window frame.
Attach the window stopping clips on the top and the bottom of the window frame (sliding windows only).
Cut the foam window side gasket to the proper length and stuff it between the 2 windows.
4 5 6 7 8
LOW FAN
HI COOL MED COOL

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Horizontal sliding window installation instructions.
Read completely, then follow step-by-step.
Trim the filler panel to fit the opening of the height of the window. Attach the top retainer bar to the top of the panel.
Drill 1/8″ holes to align with the existing holes in the sliders. Secure with 2 type C screws.
Put the filler panel into the bottom retainer (attached to the air conditioner) and extend the sliders upward making sure the panel stays in the tracks of the sliders.
4 5 6 7 8
LOW FAN
LOW COOL HI COOL MED COOL
Top retainer bar · Sliders

Casement window installation instructions.
Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Read these instructions completely and carefully.
Decide where the air conditioner will fit best. If you want to install the air conditioner in a window that does not open, you need to remove the glass panes and window dividers to provide an opening at least 153/4″ wide × 211/2″ high.
If you want to install the air conditioner in a window that opens you must remove the catch handle and the entire crank handle assembly. Then either remove the window or fold it back against the building and fasten it securely.
If the window opening is wider than 153/4″, you will need to install a filler panel. Make this panel from 3/4″ thick wood and run it the full length of the window. Attach it securely to the window frame and paint it to protect it from the weather.
LOW FAN
4 5 6 7 8
HI COOL
153/4″ wide
4 5 6 7 8
LOW FAN
MED COOL
HI COOL
213/4″ high Crank handles
Mounting procedure is similar to that described in steps 1–5 of the Horizontal Sliding Window Installation Instructions.
The installations are also typical. Since styles and sizes of casement windows vary widely, it is advisable to have the air conditioner installed by someone skilled in this type of installation.
Catch handle · Window divider

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service.
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The temp control may • Turn the knob to a higher number. The highest setting not be set high enough. provides maximum cooling.
The air filter is dirty. • Clean the filter at least every 30 days. See the Care and cleaning of the air conditioner section.
The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down.
Cold air is escaping. • Check for open furnace floor registers and cold air returns.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow • Set the mode control at HI FAN or HI COOL with freezing up and stops the air conditioner the temp at 1 or 2. Wait for approximately one hour, from cooling the room. then reset to desired temperature.
I You may hear a pinging noise caused
I Water will collect in the base pan
by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
I The fan may run even when the
compressor does not.
I You may hear the thermostat click
when the compressor cycles on and off.

Air Conditioner Warranty.
Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, contact us at www.GEAppliances.com or call 800-GE-CARES.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, GE will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this five-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
IService trips to your home to teach you how to use the
IReplacement of house fuses or resetting of circuit
product.
breakers.
IImproper installation. If you have an installation
IFailure due to corrosion on models not corrosion-
problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
IDamage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
IIncidental or consequential damage caused by possible
IFailure of the product resulting from modifications to
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
defects with this air conditioner.
IIn commercial locations labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Consumer Support.

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800-GE-CARES (800-432-2737) during normal business hours.

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800-TDD-GEAC (800-833-4322).

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800-626-2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800-626-2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park Louisville, KY 40225

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner’s Manual.
Printed in the United States
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.