EN
GE logo
Official user manual

GE AST08

20 pages·819 KB·Air Conditioner·PDF·ENDEFRITNLJA
GE AST08
Table of Contents 22 sections TABLE OF CONTENTS · Safety Information · Adapter Plugs · Connect Electricity · … ShowHide
Page 3 of the GE AST08 user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

www.GEAppliances.com

WARNING!

USE OF EXTENSION CORDS– 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

USE OF ADAPTER PLUGS – 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 4 of the GE AST08 user manual — Remote Control
Page 4 · click to enlarge
Page 4

About the controls on the air conditioner–models with touch pads.

Features and appearance will vary.

Air Conditioner Controls Remote Control

ON/OFF Turns air conditioner on and off.

TIMER

ON–When the air conditioner is off, it can be

set to automatically come on in 1 to 24 hours at its previous setting. Each touch will set the time in hours.

Display

MODE Use to set the air conditioner to COOL or FAN.

OFF–When the air conditioner is on, it can be

set to automatically turn off in 1 to 24 hours. Each touch will set the time in hours.

Increase L /Decrease M Pads Use to set temperature when in COOL mode.

FAN Use to set the fan speed at LOW, MED or HIGH.

To cancel the timer, press the TIMER pad until the display time disappears.

CIRCULAIRE Turn on to provide continuous side-to-side air circulation.

SLEEP Press to set the air conditioner to run for 8 hours before it automatically shuts off.

For fixed side-to-side air direction, turn ON until the desired air direction is obtained, then turn it OFF.

When the SLEEP pad is pressed, SLEEP scrolls across the display for approximately 15 seconds, then shows the time remaining.

ENERGY SAVER–Controls the fan.

One hour after the sleep timer is set, the set temperature will automatically increase 1°F.

ON–The fan and compressor cycle on and off.

This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. Note: The fan will continue to run for a short time after the compressor cycles off.

To cancel the sleep mode, press the SLEEP pad a second time.

Remote Control Signal Receiver

OFF–The fan runs all the time, while the

compressor cycles on and off.

This switch must be set at OFF in order to use the fan settings (on the mode control).

Remote Control

I To ensure proper operation, aim the

I Make sure nothing is between the air

remote control at the signal receiver on the air conditioner.

conditioner and the remote control that could block the signal.

I The remote control signal has a range of up

I Make sure batteries are fresh and installed

to 21 feet.

correctly–see the Care and Cleaning section.

Show 8 more labels / short text on this page
Low Fan On · Med Fan On · High Fan On · CIRCULAIRE On · ENERGY SAVER On · Cool Mode On · Fan Only On · Timer On
Page 5 of the GE AST08 user manual — OR
Page 5 · click to enlarge
Page 5

www.GEAppliances.com

When the air conditioner is turned on, it will automatically start in the setting last used.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

COOL Mode

Use the COOL mode with HIGH, MED or LOW fan for cooling. Use the INCREASE L / DECREASE M pads to set the desired temperature between 64°F and 86°F in 1°F increments.

For Normal Cooling–Select the COOL mode and HIGH or MED fan with a middle set temperature.

For Maximum Cooling–Select the COOL mode and HIGH fan with a lower set temperature.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

For Quieter & Nighttime Cooling–Select the COOL mode and LOW fan with a middle set temperature.

FAN Mode

Use the FAN at HIGH, MED or LOW to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.

Vent Control

The vent control is located on the inside of the air louvers in the lower right corner.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, push the lever to the right. To close it, push it to the left.

Air Direction – Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

OR

Cooling Descriptions

Page 6 of the GE AST08 user manual — Cooling Descriptions
Page 6 · click to enlarge
Page 6

About the controls on the air conditioner–models with control knobs.

Features and appearance will vary.

OFF

OFF LOW

HI FAN

OFF

FAN

HIGH

HIGH COOL

FAN

HI FAN

HI COOL

LOW

MED COOL

LOW COOL

HI COOL

FAN

LOW

LOW COOL

FAN

MED COOL

LOW COOL

MODE CONTROLS

Your model will have one of the above type controls.

TEMP CONTROLS

Your model will have one of the above type controls.

Controls

Mode Controls

Temp Controls

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.

For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available on your knob.

For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.

Page 7 of the GE AST08 user manual — OR
Page 7 · click to enlarge
Page 7

www.GEAppliances.com

Additional controls and important information.

Energy Saver (on some models)

The energy saver switch controls the fan.

OFF —The fan runs all the time, while the compressor cycles on and off.

ON —The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.

This switch must be set at OFF in order to use the fan settings (on the mode control).

Vent Control (on some models)

The vent control is located on the inside of the air louvers in the lower right corner.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, push the lever to the right. To close it, push it to the left.

Air Direction – Side-to-Side

On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers.

CIRCULAIRE (on some models)

For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained, then move it to OFF.

OR

For continuous side-to-side air circulation, set the Circulaire switch to ON and leave it there.

Air Direction – Up and Down (on some models)

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

OR

Page 8 of the GE AST08 user manual — To remove (on some models): 2
Page 8 · click to enlarge
Page 8

Care and cleaning of the air conditioner.

How to Insert the Batteries

Remove the battery cover by sliding it according to the arrow direction.

NOTES:

I Use 2 “AAA” (1.5 volt) batteries. Do not use

Insert new batteries making sure that the (+) and (–) of battery are installed correctly.

rechargeable batteries.

I Remove the batteries from the remote control if

the system is not going to be used for a long time. 3

Reattach the cover by sliding it back into position.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove (on some models):

Grab the tabs on the filter and pull it up and out.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

To remove (on some models):

Open the inlet grille upward by pulling out the bottom of the inlet grille.

To remove (on some models): 2

Using the tab, pull up slightly on the filter to release it and pull it down.

Grab the tab on the filter and pull it to the right.

Page 9 of the GE AST08 user manual — Tools You Will Need
Page 9 · click to enlarge
Page 9

Preparing to install the air conditioner.

Read these instructions completely and carefully.

Before You Begin

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local codes and ordinances.

Electrical Requirements

Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Tools You Will Need

I Scissors or knife

I Ruler or tape measure

Show 4 more labels / short text on this page
I Phillips-head screwdriver · I Adjustable wrench · I Pencil · I Level
Page 10 of the GE AST08 user manual — Window Installation
Page 10 · click to enlarge
Page 10
GE AST08 — Window Installation diagram (page 10)
Fig. 1 · Window Installation

Read the section Preparing to Install the Air Conditioner before beginning.

Page 11 of the GE AST08 user manual — A
Page 11 · click to enlarge
Page 11

Read completely, then follow step-by-step.

Window Requirements

IThese instructions are for a standard double-

IAll supporting parts must be secured to firm

hung window. You will need to modify them for other types of windows.

wood, masonry or metal.

IThe electrical outlet must be within reach of the

IThe air conditioner can be installed without

power cord.

the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.

AS_06

143⁄4″ min.

161⁄8″ min.

251⁄2″ to 37″ (With accordion panels)

275⁄8″ to 41″ (With accordion panels)

201⁄2″ min. (Without accordion panels)

235⁄8″ min. (Without accordion panels)

Storm Window Requirements

A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

WOOD PIECES—

WIDTH: 2 ″

LENGTH: Long enough to fit inside the window frame.

1/2″ higher than frame

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Lift the grille up and off the top tabs. C 3

Remove the Front Grille, if attached

To remove the grille:

Remove shipping tape if present. On models with a slide out air filter, remove it (see the Care and Cleaning section) and the screw behind it (if present) that holds the grille in place. On models with a raise up inlet grille, lift it (see the Care and Cleaning section) and remove the screw behind it (if present) that holds the grille in place.

A

Pull the bottom grille corners out to release the lower tabs on each side. B

Show 5 more labels / short text on this page
AS_10 models · and AS_08 models · Wood · Stool · Storm window frame
Page 12 of the GE AST08 user manual — B A
Page 12 · click to enlarge
Page 12

Window Installation Instructions.

Remove the Air Conditioner From the Case

Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. B A

Remove the 2 screws on each side of the case. Keep these for later use.

Front of air conditioner.

Front of air conditioner.

Remove packing cardboard and tape if present.

Prepare the Case

Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.

Install the top mounting rail with 4 type A or 5 type A screws (as the installation requires) from the outside of the case.

B A

Insert the frames for the accordion panels into the top and bottom mounting rails. Attach the accordion panels to the side of the case using 6 type A or 8 type A screws (as the installation requires).

Top mounting rail · Bottom mounting rail

Page 13 of the GE AST08 user manual — Install the Security Bracket and the Foam Top Window Gasket
Page 13 · click to enlarge
Page 13

A 6

Install the Case in the Window

Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.

Locate the 3 screw holes along the bottom front edge of the case. Center the case, side to side, in the window and mount it to the window sill using 3 type B screws.

Type B screws Type B screws

Thread two type C bolts into the support brackets.

B

Slide the case into the window and lower the window behind the top mounting rail.

Position the brackets on the case bottom so they will be near the outermost point on the window sill. Attach the support brackets to each side of the case bottom using 4 type A screws on each side. The case should be slightly tilted to the outside. Use a level; about a 1/2 bubble will be the correct case slant to the outside.

Extend the left and right accordion panels to the vertical window sashes and attach with 4 type B screws. D

B A 7

Install the Security Bracket and the Foam Top Window Gasket

Attach the security bracket with a type B screw. Cut the foam top window gasket to the window width.

Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C

Show 5 more labels / short text on this page
Top mounting rail · Window sash seal · Type B screws · Type A screws · Type C bolts
Page 14 of the GE AST08 user manual — D
Page 14 · click to enlarge
Page 14

Window Installation Instructions.

Install the Air Conditioner in the Case

A

Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case.

Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place.

Place the bottom inner case gasket between the bottom of the air conditioner and the inside bottom of the case. Fold up the ends on both sides and push them in.

B

Guide the lever carefully through the grille as you push it in.

Front of air conditioner.

D

Secure the front grille to the case by replacing the screw removed in Step 3. If a screw was not removed in Step 3, secure the grille with a type A screw. The installation is now complete.

Bottom inner · case gasket

Page 15 of the GE AST08 user manual — OUTSIDE
Page 15 · click to enlarge
Page 15

Through the Wall Installation Instructions–Optional.

The case may be installed through the wall in both existing and new construction. Read completely, then follow step-by-step.

IMPORTANT

Through the wall installation is not appropriate if any of the side louvers in the case will be obstructed by the wall.

All side louvers in the case must project on the outdoor side of the wall.

The room side of the case must project into the room at least 13⁄4″ from the finished wall.

The case must be installed level from side-to-side and with a slight tilt from front to rear. Use a level; about a 1/2 bubble will be the correct case slant to the outside.

A

Remove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions.

Place the case in the wall opening and secure with 12 1″ long #10 wood screws.

C B

Make certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle.

Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the outside of the building. 2

Finish the Wall Opening

Lintel angle (if required)

Trim molding (if desired)

OUTSIDE

INSIDE

Air louvers (must project on the outdoor side of the wall.)

Wood Filler and Caulking (above & below the flashing)

4.5 cm (13/4″) min.

Show 4 more labels / short text on this page
Plaster line · Caulking · Bottom rail · Flashing (Drip rail)
Page 16 of the GE AST08 user manual — Normal Operating Sounds
Page 16 · click to enlarge
Page 16

Before you call for service…

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do

Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.

The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.

Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.

  • The temp control may
  • On models with touch pads: In COOL mode, press the not be set correctly. DECREASE M pad.
  • On models with control knobs, turn the temperature knob to a higher number.

The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.

The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down.

Cold air is escaping. • Check for open furnace floor registers and cold air returns.

  • Set the air conditioner’s vent to the closed position.

Cooling coils have iced up. • See “Air conditioner freezing up” below.

  • Air conditioner Ice blocks the air flow
  • On models with control knobs, set the mode control at freezing up and stops the air conditioner HIGH FAN or HIGH COOL with the temp at 1 or 2 . from cooling the room.
  • On models with touch pads, set the controls at HIGH FAN or HIGH COOL and set the thermostat to a higher temperature.

The remote control is The batteries are inserted • Check the position of the batteries. They should be not working incorrectly. inserted in the opposite (+) and (–) direction.

The batteries may be dead. • Replace the batteries.

Water drips outside Excessively hot and • This is normal. humid weather.

Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.

Water collects in Moisture is removed from • This is normal for a short period in areas with little base pan indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil.

Normal Operating Sounds

I You may hear a pinging noise caused by water

I Water will collect in the base pan during

being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

I The fan may run even when the compressor

I You may hear the thermostat click when the

does not.

compressor cycles on and off.

Page 17 of the GE AST08 user manual — General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150
Page 17 · click to enlarge
Page 17

GE Service Protection Plus ™

GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™—comprehensive protection on all your appliances— No Matter What Brand!

  • Benefits Include:
  • Backed by GE
  • All brands covered
  • Unlimited service calls
  • All parts and labor costs included
  • No out-of-pocket expenses
  • No hidden deductibles
  • One 800 number to call

We’ll Cover Any Appliance. Anywhere. Anytime.*

You will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract. No questions asked. It’s that simple.

Protect your refrigerator, dishwasher, washer and dryer, range, TV, VCR and much more—any brand! Plus there’s no extra charge for emergency service and low monthly financing is available. Even icemaker coverage and food spoilage protection is offered. You can rest easy, knowing that all your valuable household products are protected against expensive repairs.

Place your confidence in GE and call us in the U.S. toll-free at 800-626-2224 for more information.

*All brands covered, up to 20 years old, in the continental U.S.

! Cut here

Please place in envelope and mail to:

General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150

Page 18 of the GE AST08 user manual — Model Number Serial Number
Page 18 · click to enlarge
Page 18

Consumer Product Ownership Registration

Dear Customer: Thank you for purchasing our product and thank you for placing your confidence in us. We are proud to have you as a customer!

Follow these three steps to protect your new appliance investment:

product, detach and return the form below to ensure that your product is registered, or register online at www.GEAppliances.com 1 2 3

Complete and mail your Consumer Product Ownership Registration today. Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification.

After mailing the registration below, store this document in a safe place. It contains information you will need should you require service. Our service number is 800 GE CARES (800-432-2737).

Read your Owner’s Manual carefully. It will help you operate your new appliance properly.

Model Number Serial Number

Important: If you did not get a registration card with your

! Cut here

Consumer Product Ownership Registration

Model Number Serial Number

Mr. I Ms. I Mrs. I Miss I

Apt. #

Phone Number _ _

In Use Month Day Year

Occasionally, we may allow selected companies to send you information. I Check here if you do not want this information.

General Electric Company Louisville, Kentucky www.GEAppliances.com

Show 8 more labels / short text on this page
Mail Today! · First Name · Last Name · Street Address · E-mail Address · Zip Code · City State · Date Placed
Page 19 of the GE AST08 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 19 · click to enlarge
Page 19

Air Conditioner Warranty.

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, contact us at www.GEAppliances.com or call 800-GE-CARES.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: We Will Replace:

One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, we will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.

Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this four-year additional warranty, we will also provide, free of charge, all labor and in-home service to replace the defective part.

What Is Not Covered:

IService trips to your home to teach you how to use the

IReplacement of house fuses or resetting of circuit

product.

breakers.

IImproper installation. If you have an installation problem,

IFailure due to corrosion on models not corrosion-

or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

protected.

IDamage to the product caused by improper power supply

voltage, accident, fire, floods or acts of God.

IIncidental or consequential damage caused by possible

IFailure of the product resulting from modifications to the

defects with this air conditioner.

product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

IIn commercial locations labor necessary to move the

unit to a location where it is accessible for service by an individual technician.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 20 of the GE AST08 user manual — Consumer Support
Page 20 · click to enlarge
Page 20

Consumer Support.

GE AST08 — Consumer Support diagram (page 20)
Fig. 2 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...

GE AST08 — Consumer Support diagram (page 20)
Fig. 3 · Consumer Support

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800-GE-CARES (800-432-2737) during normal business hours.

GE AST08 — Consumer Support diagram (page 20)
Fig. 4 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800-TDD-GEAC (800-833-4322).

GE AST08 — Consumer Support diagram (page 20)
Fig. 5 · Consumer Support

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800-626-2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE AST08 — Consumer Support diagram (page 20)
Fig. 6 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800-626-2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE AST08 — Consumer Support diagram (page 20)
Fig. 7 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park Louisville, KY 40225

GE AST08 — Consumer Support diagram (page 20)
Fig. 8 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner’s Manual.

Printed in Korea

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Air conditioner does not startThe air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. p.16
Air conditioner does not cool as it shouldAirflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • On models with touch pads: In COOL mode, press the not be set correctly. DECREASE M pad. • On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace floor registers and cold air returns. • Set the air conditioner’s vent to the closed position. Cooling coils have iced up. • See “Air conditioner freezing up” below. p.16
Air conditioner freezing upIce blocks the air flow • On models with control knobs, set the mode control at and stops the air conditioner HIGH FAN or HIGH COOL with the temp at 1 or 2. from cooling the room. • On models with touch pads, set the controls at HIGH FAN or HIGH COOL and set the thermostat to a higher temperature. p.16
The remote control is not workingThe batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. p.16
Water drips outsideExcessively hot and • This is normal. humid weather. p.16
Water drips indoorsThe air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. p.16
Water collects in base panMoisture is removed from • This is normal for a short period in areas with little indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil. p.16

Ask about the GE AST08

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE AST08

Be the first to ask — other owners or our team will answer.

Original document

GE AST08 manual PDF

20 pages·819 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…