Air Conditioners Room
Safety Instructions 2, 3
Operating Instructions 4, 5
Care and Cleaning Air Filter 6 Grille and Case 6 Outdoor Coils 6
Installation Instructions Preparing to Install the Air Conditioner 7 Window Installation 8–12
Troubleshooting Tips 13 Normal Operating Sounds . . .14
Consumer Support Consumer Support 18 Product Registration 15, 16 Warranty 17
Write the model and serial numbers here:
Find these numbers on a label on the side of the air conditioner.
Model # · Serial #

I Use this appliance only for its intended
I Turn the mode control to OFF and unplug
purpose as described in this Owner’s Manual.
your air conditioner before making any repairs or cleaning.
I This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
I Never unplug your air conditioner by
I For your safety…do not store or use
pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
I Repair or replace immediately all electric
I All air conditioners contain refrigerants,
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

USE OF EXTENSION CORDS— 115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
SAVE THESE INSTRUCTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

About the controls on the air conditioner.
Features and appearance may vary.
Remote Control
Controls
ON/OFF Pad Turns air conditioner on and off.
TIMER Pad ON—When the air conditioner is off, it can be set to automatically come on in 1 to 12 hours at its previous setting. Each touch will set the timer in hours.
Increase L /Decrease M Pads Use to set temperature when in COOL mode.
MODE Use to set the air conditioner to COOL or FAN mode.
OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the timer in hours.
FAN Pad Use to set the fan speed to LOW (F1), MED (F2) or HIGH (F3).
To cancel the timer, press the TIMER pad until the display time disappears.
Remote Control Signal Receiver
Display Shows the set temperature or time remaining on timer.
I To ensure proper operation, aim the remote
I Make sure nothing is between the air conditioner
control at the signal receiver on the air conditioner.
and the remote control that could block the signal.
I The remote control signal has a range of
I Make sure batteries are fresh and installed
up to 21 feet.
correctly as indicated on the remote control.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Use the COOL mode with HIGH (F3), MED (F2) or LOW (F1) fan for cooling. Use the INCREASE L / DECREASE M pads to set the desired temperature between 60°F and 86°F in 1°F increments.
For Normal Cooling—Select the COOL mode and HIGH (F3) or MED (F2) fan with a middle set temperature.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
For Maximum Cooling—Select the COOL mode and HIGH (F3) fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode and LOW (F1) fan with a middle set temperature.
Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
The vent control is located above the control panels.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.
To open the vent, pull the lever toward you. To close it, push it in.
The side-to-side air direction is adjusted by moving the lever to the left or right.
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Cooling Descriptions

Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille downward by pulling out the top corners of the inlet grille.
Pull up slightly on the filter to release it and pull it out.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
Read these instructions completely and carefully.
ELECTRICAL REQUIREMENTS
Ruler or tape measure Pencil
Some models require a 115/120-volt a.c., 60 Hz ground.d outlet protect.d with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replac.d with a proc.0ly ground.d 3-prong wall outlet.
Some models require 230/208-volt a.c., protect.d with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Phillips head screwdriver · Level



1 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES– WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.
8,000 and 10,000 BTU models
1/2″ higher than frame
15″ min.
25″ to 36″ (With accordion panels)
20″ min. (Without accordion panels)
16″ min.
27″ to 39″ (With accordion panels)
237⁄8″ min. (Without accordion panels)



Remove the 2 shipping screws from the back of the case.
Carefully insert the plastic frame guides into the bottom of the case on each side.
Remove the 2 screws on each side of the case. Keep these for later use.
Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. C
Install the top mounting rail with 3 type A screws on the inside of the case. Insert the frames for the accordion panels into the top mounting rail and the frame guides. Attach the accordion panels to the side of the case using 4 type A screws on each side.

Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash. A



Open the window and mark the centerline of the window stool.
Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside. Use a level; about 1/3 bubble will be the correct case slant to the outside.
Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool.
Pull the window down behind the top mounting rail.
Secure the case to the window stool by using 3 type B screws.
Pull the accordion panels to each window sash track. Attach them on each side to the window sash and the window stool using 4 type C screws.
Select the position that will place the sill supports near the outermost point on the sill. Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support.



Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.
Attach a support bracket with a Type C screw.
Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C
Guide the lever carefully through the grille as you push it in.

Lower the inlet grille and secure the front frame with a type A screw through the front grille. Raise the inlet grille back into place.
Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case.

Troubleshooting Tips. Save time and money! Review the chart below first and you may not need to call for service.
Problem Possible Causes What To Do
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner does not Airflow is restricted. • Make sure there are no curtains, blinds or furniture cool as it should blocking the front of the air conditioner.
The temp control may not • In COOL mode, press the DECREASE Mpad. be set correctly.
The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.
The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping. • Check for open furnace floor registers and cold air returns.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow and • Set the controls at HIGH (F3) FAN or HIGH (F3) COOL and freezing up stops the air conditioner set the thermostat to a higher temperature. from cooling the room.
The remote control The batteries are inserted • Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. • Replace the batteries.
Water drips outside Excessively hot and • This is normal. humid weather.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture is removed from • This is normal for a short period in areas with little base pan indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil.
TIMER feature not A power outage or interruption • In the case of a power outage or interruption, the unit working properly occurred. TIMER feature will reset to the original setting. You may need to set a new time if desired.

Troubleshooting Tips.
I You may hear a pinging noise caused by water
I Water will collect in the base pan during high
being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
I The fan may run even when the compressor
I You may hear the thermostat click when the
does not.
compressor cycles on and off.

GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™---comprehensive protection on all your appliances--- No Matter What Brand!
You will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract. No questions asked. It’s that simple.
Protect your refrigerator, dishwasher, washer and dryer, range, TV, VCR and much more---any brand! Plus there’s no extra charge for emergency service and low monthly financing is available. Even icemaker coverage and food spoilage protection is offered. You can rest easy, knowing that all your valuable household products are protected against expensive repairs.
Place your confidence in GE and call us in the U.S. toll-free at 800.626.2224 for more information.
*All brands covered, up to 20 years old, in the continental U.S.
Please place in envelope and mail to:

Dear Customer: Thank you for purchasing our product and thank you for placing your confidence in us. We are proud to have you as a customer!
product, detach and return the form below to ensure that your product is registered, or register online at GEAppliances.com. 1 2 3
Complete and mail your Consumer Product Ownership Registration today. Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification.
After mailing the registration below, store this document in a safe place. It contains information you will need should you require service. Our service number is 800.GE.CARES (800.432.2737).
Read your Owner’s Manual carefully. It will help you operate your new appliance properly.
Important: If you did not get a registration card with your
✁ Cut here
Consumer Product Ownership Registration
Model Number Serial Number
Mr. I Ms. I Mrs. I Miss I
Apt. #
Phone Number _ _
In Use Month Day Year
* Please provide your e-mail address to receive, via e-mail, discounts, special offers and other important communications from GE Appliances (GEA). I Check here if you do not want to receive communications from GEA’s carefully selected partners.
FAILURE TO COMPLETE AND RETURN THIS CARD DOES NOT DIMINISH YOUR WARRANTY RIGHTS.
GE Consumer & Industrial Louisville, Kentucky www.GEAppliances.com
For information about GEA’s privacy and data usage policy, go to www.GEAppliances.com and click on “Privacy Policy” or call 800.626.2224.

Air Conditioner Warranty.
All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at GEAppliances.com, or call 800.GE.CARES (800.432.2737).
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, we will also provide, free of charge, all labor and in-home original purchase service to replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator and From the date of the all connecting tubing) which fails due to a defect in materials or workmanship. During this original purchase four-year additional warranty, we will also provide, free of charge, all labor and in-home service to replace the defective part.
IService trips to your home to teach you how to
IReplacement of house fuses or resetting of circuit
use the product.
breakers.
IImproper installation, delivery or maintenance. If you
IFailure due to corrosion on models not corrosion-
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
IDamage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
IIncidental or consequential damage caused by possible
IFailure of the product resulting from modifications to
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
IDamage caused after delivery.
IIn commercial locations labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Consumer Support.

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE supports the Universal Design concept---products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park Louisville, KY 40225

Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.
18 Printed in China
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Air conditioner does not start | The air conditioner • Make sure the air conditioner plug is pushed completely is unplugged. into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | p.13 | |
| Air conditioner does not cool as it should | Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may not • In COOL mode, press the DECREASE Mpad. be set correctly. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace floor registers and cold air returns. • Set the air conditioner’s vent to the closed position. Cooling coils have iced up. • See “Air conditioner freezing up” below. | p.13 | |
| Air conditioner freezing up | Ice blocks the air flow and • Set the controls at HIGH (F3) FAN or HIGH (F3) COOL and stops the air conditioner set the thermostat to a higher temperature. from cooling the room. | p.13 | |
| The remote control is not working | The batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. | p.13 | |
| Water drips outside | Excessively hot and • This is normal. humid weather. | p.13 | |
| Water drips indoors | The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. | p.13 | |
| Water collects in base pan | Moisture is removed from • This is normal for a short period in areas with little indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil. | p.13 | |
| TIMER feature not working properly | A power outage or interruption • In the case of a power outage or interruption, the unit occurred. TIMER feature will reset to the original setting. You may need to set a new time if desired. 13 | p.13 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.