Room Air Conditioners
Pub. No. 49-7368-1 CG 12-97

Welcome to the GE family. We’re proud of our quality products and we are committed to providing dependable service. You’ll see it in this easy-to-use Owner’s Manual and you’ll hear it in the friendly voices of our customer service department.

Best of all, you’ll experience these values each time you use your air conditioner. That’s important, because your new air conditioner will be part of your family for many years. And we hope you will be part of ours for a long time to come.
We thank you for buying GE. We appreciate your purchase, and hope you will continue to rely on us whenever you need quality appliances for your home.
GE & You, A Service Partnership.
Fill out and return the Consumer Product Registration Card that is packed with this product.
#
#
You can find them on a label on the side of the air conditioner.
Staple sales slip or cancelled check here.
Proof of the original purchase date is needed to obtain service under the warranty.
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You’ll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
If you do need service, you can relax knowing help is only a phone call away. A list of toll-free customer service numbers is included in the back section. Or, you can always call the GE Answer Center® at 800.626.2000, 24 hours a day, 7 days a week.

I This air conditioner must be properly
I Turn the mode control to OFF and unplug
installed in accordance with the Installation Instructions before it is used.
your air conditioner before making any repairs.
I Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged.
The use of an extension cord is not recommended. However, if an extension cord is required to reach the nearest wall receptacle, use only a UL-listed, 3-wire, grounded, 14 gauge, 15A, 125V appliance extension cord.
Because most 2-prong outlets are not grounded, we strongly advise against using an adapter plug. However, a temporary connection may be made where local codes permit and if the 2-prong wall outlet is properly grounded. UL-listed adapters are available at most hardware stores.
I Screw the adapter to the outlet, using the
outlet cover screw.
I Ground the outlet through the house wiring.
When disconnecting the power cord from the adapter, hold the adapter close to the outlet while pulling the plug out. If this is not done, the grounding connector is likely to break with repeated use.
When you plug the adapter in, make sure the larger prong goes into the larger slot to provide the proper polarity for the power cord.
If the grounding connector breaks, DO NOT USE the air conditioner until a proper ground has again been made.

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions
About the controls on the air conditioner.
The controls will look like one of the following.
OFF
HIGH
HIGH COOL
HI FAN
HI COOL
FAN
LOW
MED COOL
LOW
LOW COOL
FAN
FAN
LOW COOL
MODE CONTROLS
TEMP CONTROLS
Controls
Mode Controls
Temp Controls
HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
LOW FAN or HIGH FAN provides air circulation and filtering without cooling.
For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.
For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available on your knob.
For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.

Additional controls and important information.
Energy Saver (on some models)
The energy saver switch controls the fan.
ENERGY SAVER OFF—The fan runs all the time, while the compressor cycles on and off.
ENERGY SAVER ON—The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity.
The vent control is located above the control knobs.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.
To open the vent, pull the lever toward you. To close it, push it in.
The horizontal air direction is adjusted by moving the lever to the left or right.
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions
Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille upward by pulling out the bottom of the inlet grille.
Using the tab, pull up slightly on the filter to release it and pull it down.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

Preparing to install the air conditioner.
Read these instructions completely and carefully.
Do not change the plug on the power cord of this air conditioner.
For personal safety, this air conditioner must be properly grounded.
Aluminum house wiring may present special problems—consult a qualified electrician.
It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
Follow National Electric Codes (NEC) and/or local codes and ordinances.
This model requires a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
I Scissors or knife
I Ruler or tape measure


Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Read completely, then follow step-by-step.
IThese instructions are for a standard double-
hung window. You will need to modify them for other types of windows.
IThe air conditioner can be installed without the
accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.
14² min.
IAll supporting parts must be secured to firm
25² to 36² (With accordion panels)
wood, masonry or metal.
IThe electrical outlet must be within reach of the
power cord.
201/8²min. (Without accordion panels)
Window opening dimensions are for a standard double-hung window.
A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WIDTH: 2 ²
LENGTH: Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2² higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
Wood · Stool

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions
A 3
Remove the 2 shipping screws from the back of the case.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. C
Remove the 2 screws on each side of the case. Keep these for later use.
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.
D
Install the top mounting rail with 3 type A screws on the inside of the case. Insert the frames for the accordion panels into the top mounting rail and the frame guides. Attach the accordion panels to the side of the case using 4 type A screws.
Carefully insert the plastic frame guides into the bottom of the case on each side.

Open the window and mark the centerline of the window stool.
Adjust the bolt and the nut in each support so that the case is installed with a slight downward tilt (about 1/8²).
Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool.
Secure the case to the window stool by using 3 type B screws.
Pull the window down behind the top mounting rail.
Pull the accordion panels to each window sash track. Attach them on each side to the window sash and the window stool using 4 type C screws.
Loosely assemble the sill supports.
OUTDOOR
E
Select the position that will place the sill supports near the outermost point on the sill. Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support.

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions
B A 6
Attach the window locking bracket with a type C screw.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C
Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case.
Lift the inlet grille and secure it with a type A screw through the front grille. C
Attach the front grille to the case by inserting the tabs on the grille into the tabs on the front of the case. Push the grille in until it snaps into place.

Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service.
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The temp control may • Turn the knob to a higher number. The highest setting not be set high enough. provides maximum cooling.
The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.
The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down.
Cold air is escaping. • Check for open furnace floor registers and cold air returns.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow • Set the mode control at HIGH FAN or HIGH COOL freezing up and stops the air conditioner with the temp at 1 or 2. from cooling the room.
I You may hear a pinging noise caused by water
I Water will collect in the base pan during
being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
I The fan may run even when the compressor
I You may hear the thermostat click when the
is not.
compressor cycles on and off.

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 800-GE-CARES.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, GE will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this five-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
IService trips to your home to teach you how to use the
IReplacement of house fuses or resetting of circuit
product.
breakers.
IImproper installation. If you have an installation problem,
IFailure due to corrosion on models not corrosion-
or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
IDamage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
IIncidental or consequential damage to personal property
IFailure of the product resulting from modifications to the
caused by possible defects with this air conditioner.
product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
IIn commercial locations labor necessary to move the unit
to a location where it is accessible for service by an individual technician.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Service Telephone Numbers.
The GE Answer Center® is open 24 hours a day, 7 days a week.
Expert GE repair service is only a phone call away.
GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons with limited mobility.
Purchase a GE service contract while your warranty is still in effect and you’ll receive a substantial discount. GE Consumer Service will still be there after your warranty expires.
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted).
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.
If you are not satisfied with the service you receive from GE:
First, contact the people who serviced your appliance.
Next, if you are still not pleased, write all the details—including your phone number—to:
Manager, Consumer Relations GE Appliances Appliance Park Louisville, KY 40225
Finally, if your problem is still not resolved, write:
Major Appliance Consumer Action Program 20 North Wacker Drive Chicago, IL 60606
Printed in Korea 16
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Air conditioner does not start | The air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. | p.13 | |
| Air conditioner does not cool as it should | Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • Turn the knob to a higher number. The highest setting not be set high enough. provides maximum cooling. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace floor registers and cold air returns. • Set the air conditioner’s vent to the closed position. Cooling coils have iced up. • See “Air conditioner freezing up” below. | p.13 | |
| Air conditioner freezing up | Ice blocks the air flow • Set the mode control at HIGH FAN or HIGH COOL and stops the air conditioner with the temp at 1 or 2. from cooling the room. | p.13 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.