Air Conditioners
Room
Owner’s Manual and Installation Instructions
Operating Instructions Control Knob Models 6, 7 Touch Pad Models 4, 5
Care and Cleaning Air Filter 7 Outdoor Coils 7
Troubleshooting Tips 12 Normal Operating Sounds 12
Consumer Support Consumer Support 14 Warranty 13
Write the model and serial numbers here:
Find these numbers on a label on the side of the air conditioner.
Model # · Serial #

I Use this appliance only for its intended
I Turn the unit OFF and unplug your air
purpose as described in this Owner’s Manual.
conditioner before cleaning.
I GE does not support any servicing of the air
I This air conditioner must be properly
conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
installed in accordance with the Installation Instructions before it is used.
I Never unplug your air conditioner by pulling
I For your safety…do not store or use
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
I Replace immediately all electric service
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
I All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

USE OF EXTENSION CORDS— 115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

About the controls on the air conditioner—models with touch pads.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
F
Fan speed Decrease Temperature set Increase and Decrease
Light indicates the delay timer is set.
Remote Control
Controls
Power Pad Turns air conditioner on and off. When turned on, the display will show the room temperature.
Mode Pad Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
Delay Pads Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Display Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the pad on the remote control. Each touch of the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
Temp Increase L /Decrease M Pads Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.
Delay Timer Increase L (+) /Decrease M (–) Pads Each touch of the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer ( ). The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote control. Use the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
Fan Speed Pads Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

I To ensure proper operation, aim the remote
I Make sure nothing is between the air conditioner
control at the signal receiver on the air conditioner.
and the remote control that could block the signal.
I The remote control signal has a range of
I Make sure batteries are fresh and installed
up to 20 feet.
correctly as indicated on the remote control.
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase L / Decrease M pads to set the desired temperature between 64°F and 86°F in 1°F increments.
For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
Controls the fan.
ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor cycles on and off.
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may need to set a new time if desired.

About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
TEMP
OFF
Coolest
High Cool
High
Fan
Fan Med Cool
Low
Low Cool
MODE CONTROL TEMPERATURE CONTROL
Controls
Mode Control High Cool, Med Cool and Low Cool provide cooling with different fan speeds.
TEMP Control The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
Fan settings provide air circulation and filtering without cooling.
For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint.
For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob.
For Quieter & Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.

Additional important information.
Use the lever to adjust the air direction left and right only.
Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Push on one side of the filter edge and pull it out the other side.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
Remove the battery cover by sliding it according to the arrow direction.
I Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.
use rechargeable batteries.
I Remove the batteries from the remote control if
the system is not going to be used for a long time. 3
Reattach the cover by sliding it back into position.


BEFORE YOU BEGIN
Read these instructions completely and carefully.
ELECTRICAL REQUIREMENTS
Ruler or tape measure Pencil
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Level Scissors or knife
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Phillips head screwdriver · Flat-blade screwdriver



STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES– WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.
1/2″ higher than frame
B
PREPARE THE AIR CONDITIONER Install the top mounting rail with 2 Type B screws from the outside of the case.
B
Slide the left and right accordion panels into the top and bottom mounting rails.



3 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the stool with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.
PREPARE THE AIR CONDITIONER (cont.) Attach the accordion panels to the case using 3 Type A screws on each side.
Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 4 Type C screws, as appropriate.

INSTALL A SUPPORT BRACKET AND THE FOAM TOP WINDOW GASKET Attach the support bracket with one Type C screw.

PREPARE THE WINDOW Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

Troubleshooting Tips.
I You may hear a pinging noise caused by water
I Water will collect in the base pan during
being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
I The fan may run even when the compressor
I You may hear the thermostat click when the
does not.
compressor cycles on and off.

GE Air Conditioner Warranty—One Year Limited Warranty.
Staple your receipt here. Proof of the original purchase date is needed to make a warranty claim.
One Year Replacement unit for any product which fails due to a defect in materials or workmanship. From the date of the The exchange unit is warranted for the remainder of your product’s original one-year original purchase warranty period.
IProperly pack your unit. We recommend using the
IInclude in the package a copy of the sales receipt or other
original carton and packing materials.
evidence of date of original purchase. Also print your name and address and a description of the defect.
IReturn the product to the retail location where it
was purchased.
ICustomer instruction. This owner’s manual provides
IReplacement of house fuses or resetting of circuit
information regarding operating instructions and user controls.
breakers.
IDamage to the product caused by improper power supply
IImproper installation. If you have an installation problem,
voltage, accident, fire, floods or acts of God.
or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
IIncidental or consequential damage caused by possible
defects with this air conditioner.
IFailure of the product resulting from modifications to
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.

Consumer Support.
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, or even order parts and catalogs on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...
GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park Louisville, KY 40225
Printed in China 14
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Air conditioner does not start | The air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | p.12 | |
| Air conditioner does not cool as it should | Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • On models with touch pads: In the Cool mode, press the not be set correctly. Decrease M pad. •On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace registers and cold air returns. Cooling coils have iced up. • See “Air conditioner freezing up” below. | p.12 | |
| Air conditioner freezing up | Ice blocks the air flow • On models with control knobs, set the mode control at and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2. from cooling the room. •On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. | p.12 | |
| The remote control is not working | The batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. | p.12 | |
| Water drips outside | Hot, humid weather. • This is normal. | p.12 | |
| Water drips indoors | The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. | p.12 | |
| Water collects in base pan | Moisture removed from air • This is normal for a short period in areas with little and drains into base pan. humidity; normal for a longer period in very humid areas. | p.12 |