EN
GE logo
Official user manual

GE AET05

28 pages·651 KB·Air Conditioner·PDF·ENDEFRITNLJA
GE AET05
Table of Contents 14 sections English · Safety Instructions · Operating Instructions · Control Knob Models · … ShowHide
Page 1 of the GE AET05 user manual — 49-7514-1 11-05 JR
Page 1 · click to enlarge
Page 1

ge.com

Air Conditioners

Room

Safety Instructions 2, 3

Owner’s Manual and Installation Instructions

Operating Instructions Control Knob Models 6, 7 Touch Pad Models 4, 5

AET05 AEW05 AEW06 AEW08

Care and Cleaning Air Filter 7 Outdoor Coils 7

Troubleshooting Tips 12 Normal Operating Sounds 12

Consumer Support Consumer Support 14 Warranty 13

Write the model and serial numbers here:

Find these numbers on a label on the side of the air conditioner.

49-7514-1 11-05 JR

Model # · Serial #

Page 2 of the GE AET05 user manual — HOW TO CONNECT ELECTRICITY
Page 2 · click to enlarge
Page 2

SAFETY PRECAUTIONS

I Use this appliance only for its intended

I Turn the unit OFF and unplug your air

purpose as described in this Owner’s Manual.

conditioner before cleaning.

I GE does not support any servicing of the air

I This air conditioner must be properly

conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

installed in accordance with the Installation Instructions before it is used.

I Never unplug your air conditioner by pulling

I For your safety…do not store or use

on the power cord. Always grip plug firmly and pull straight out from the receptacle.

combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

I Replace immediately all electric service

cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

I All air conditioners contain refrigerants,

which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

Page 3 of the GE AET05 user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

ge.com WARNING!

USE OF EXTENSION CORDS— 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

USE OF ADAPTER PLUGS— 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 4 of the GE AET05 user manual — Air Conditioner Controls
Page 4 · click to enlarge
Page 4

About the controls on the air conditioner—models with touch pads.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Light is in t The display always shows the room delayindicates the unit he temperature or time Set mode. The display always shows the room temperature except when setting the Set temperature or the Delay timer.

F

F

Fan speed Decrease Temperature set Increase and Decrease

Light indicates the delay timer is set.

Air Conditioner Controls

Remote Control

Controls

Power Pad Turns air conditioner on and off. When turned on, the display will show the room temperature.

Mode Pad Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

Delay Pads Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Display Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay 1–24hr pad on the unit or the pad on the remote control. Each touch of the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.

Temp Increase L /Decrease M Pads Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

Delay Timer Increase L (+) /Decrease M (–) Pads Each touch of the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer ( ). The Set light will turn on while setting.

To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote control. Use the Increase L / Decrease M pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.

To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.

Fan Speed Pads Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

Show 19 more labels / short text on this page
Delay 1–24hr · Delay · Delay timer Increase · Delay timer Decrease · Mo · de · Aut · o · Auto Fan on/off · Mode select · a · n · a · n · + · Fan speed Increase · Temp · Unit power on/off · Power
Page 5 of the GE AET05 user manual — Power Outage Recovery Feature
Page 5 · click to enlarge
Page 5

ge.com

Remote Control

I To ensure proper operation, aim the remote

I Make sure nothing is between the air conditioner

control at the signal receiver on the air conditioner.

and the remote control that could block the signal.

I The remote control signal has a range of

I Make sure batteries are fresh and installed

up to 20 feet.

correctly as indicated on the remote control.

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase L / Decrease M pads to set the desired temperature between 64°F and 86°F in 1°F increments.

Cooling Descriptions

For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.

For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.

Energy Saver Mode

Controls the fan.

ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

Auto Fan Speed

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.

If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 1–24hr

feature was set, it will resume countdown. You may need to set a new time if desired.

Page 6 of the GE AET05 user manual — Cooling Descriptions
Page 6 · click to enlarge
Page 6

About the controls on the air conditioner—models with control knobs.

Features and appearance will vary.

MODE

TEMP

OFF

Coolest

High Cool

High

Fan

Fan Med Cool

Low

Low Cool

MODE CONTROL TEMPERATURE CONTROL

Controls

Mode Control High Cool, Med Cool and Low Cool provide cooling with different fan speeds.

TEMP Control The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

Fan settings provide air circulation and filtering without cooling.

Cooling Descriptions

For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint.

For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob.

For Quieter & Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.

Page 7 of the GE AET05 user manual — NOTES:
Page 7 · click to enlarge
Page 7

ge.com

Additional important information.

Air Direction

Use the lever to adjust the air direction left and right only.

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Push on one side of the filter edge and pull it out the other side.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Batteries in the Remote Control

Remove the battery cover by sliding it according to the arrow direction.

NOTES:

I Use 2 “AAA” (1.5 volt) alkaline batteries. Do not

Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.

use rechargeable batteries.

I Remove the batteries from the remote control if

the system is not going to be used for a long time. 3

Reattach the cover by sliding it back into position.

Page 8 of the GE AET05 user manual — TOOLS YOU WILL NEED
Page 8 · click to enlarge
Page 8
GE AET05 — Installation Instructions diagram (page 8)
Fig. 1 · Installation Instructions

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT — Save these instructions for local inspector’s use.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.

TOOLS YOU WILL NEED

ELECTRICAL REQUIREMENTS

Ruler or tape measure Pencil

Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Level Scissors or knife

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

Phillips head screwdriver · Flat-blade screwdriver

Page 9 of the GE AET05 user manual — Installation Instructions
Page 9 · click to enlarge
Page 9
GE AET05 — Installation Instructions diagram (page 9)
Fig. 2 · Installation Instructions
Page 10 of the GE AET05 user manual — A
Page 10 · click to enlarge
Page 10
  • WINDOW REQUIREMENTS
  • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
  • The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
  • All supporting parts must be secured to firm wood, masonry or metal.
  • The electrical outlet must be within reach of the power cord.
  • Follow the dimensions in the table and illustration for your model.

STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES– WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.

ModelsABC AET05, AEW0513 1/4″ min.22″–38″ 18 1/4″ min. AEW06, AEW0814 1/2″ min.23″–38″19″ min.

1/2″ higher than frame

A

B

PREPARE THE AIR CONDITIONER Install the top mounting rail with 2 Type B screws from the outside of the case.

A

B

Slide the left and right accordion panels into the top and bottom mounting rails.

Show 9 more labels / short text on this page
Wood · Stool · Storm window frame · (With accordion panels) · Top mounting rail · (Without accordion panels) · Bottom mounting rail · Top right · Top left
Page 11 of the GE AET05 user manual — Installation Instructions
Page 11 · click to enlarge
Page 11
GE AET05 — Installation Instructions diagram (page 11)
Fig. 3 · Installation Instructions
GE AET05 — Installation Instructions diagram (page 11)
Fig. 4 · Installation Instructions

3 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the stool with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.

PREPARE THE AIR CONDITIONER (cont.) Attach the accordion panels to the case using 3 Type A screws on each side.

Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 4 Type C screws, as appropriate.

GE AET05 — Installation Instructions diagram (page 11)
Fig. 5 · Installation Instructions

INSTALL A SUPPORT BRACKET AND THE FOAM TOP WINDOW GASKET Attach the support bracket with one Type C screw.

GE AET05 — Installation Instructions diagram (page 11)
Fig. 6 · Installation Instructions

PREPARE THE WINDOW Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.

Cut the foam top window gasket to the window width.

Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

Page 12 of the GE AET05 user manual — Normal Operating Sounds
Page 12 · click to enlarge
Page 12

Troubleshooting Tips.

ProblemPossible Causes What To Do Air conditioner does not startThe air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. Air conditioner does not cool as it shouldAirflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • On models with touch pads: In the Cool mode, press the not be set correctly. Decrease M pad. •On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace registers and cold air returns. Cooling coils have iced up. • See “Air conditioner freezing up” below. Air conditioner freezing upIce blocks the air flow • On models with control knobs, set the mode control at and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2. from cooling the room. •On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. The remote control is not workingThe batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. Water drips outsideHot, humid weather. • This is normal. Water drips indoorsThe air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. Water collects in base panMoisture removed from air • This is normal for a short period in areas with little and drains into base pan. humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

I You may hear a pinging noise caused by water

I Water will collect in the base pan during

being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

I The fan may run even when the compressor

I You may hear the thermostat click when the

does not.

compressor cycles on and off.

Page 13 of the GE AET05 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 13 · click to enlarge
Page 13

GE Air Conditioner Warranty—One Year Limited Warranty.

Staple your receipt here. Proof of the original purchase date is needed to make a warranty claim.

For The Period Of: We Will Replace:

One Year Replacement unit for any product which fails due to a defect in materials or workmanship. From the date of the The exchange unit is warranted for the remainder of your product’s original one-year original purchase warranty period.

In Order to Make a Warranty Claim:

IProperly pack your unit. We recommend using the

IInclude in the package a copy of the sales receipt or other

original carton and packing materials.

evidence of date of original purchase. Also print your name and address and a description of the defect.

IReturn the product to the retail location where it

was purchased.

What Is Not Covered:

ICustomer instruction. This owner’s manual provides

IReplacement of house fuses or resetting of circuit

information regarding operating instructions and user controls.

breakers.

IDamage to the product caused by improper power supply

IImproper installation. If you have an installation problem,

voltage, accident, fire, floods or acts of God.

or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

IIncidental or consequential damage caused by possible

defects with this air conditioner.

IFailure of the product resulting from modifications to

the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.

Warrantor: General Electric Company. Louisville, KY 40225

Page 14 of the GE AET05 user manual — Contact Us ge.com
Page 14 · click to enlarge
Page 14

Consumer Support.

GE Appliances Website ge.com

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, or even order parts and catalogs on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...

Real Life Design Studio ge.com

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Parts and Accessories ge.com

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

Contact Us ge.com

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park Louisville, KY 40225

Printed in China 14

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Air conditioner does not startThe air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. p.12
Air conditioner does not cool as it shouldAirflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • On models with touch pads: In the Cool mode, press the not be set correctly. Decrease M pad. •On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace registers and cold air returns. Cooling coils have iced up. • See “Air conditioner freezing up” below. p.12
Air conditioner freezing upIce blocks the air flow • On models with control knobs, set the mode control at and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2. from cooling the room. •On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. p.12
The remote control is not workingThe batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. p.12
Water drips outsideHot, humid weather. • This is normal. p.12
Water drips indoorsThe air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. p.12
Water collects in base panMoisture removed from air • This is normal for a short period in areas with little and drains into base pan. humidity; normal for a longer period in very humid areas. p.12

Ask about the GE AET05

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE AET05

Be the first to ask — other owners or our team will answer.

Original document

GE AET05 manual PDF

28 pages·651 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…