Help us help you...
Ene~y-savi~ tips
usi~ your air conditioner, read this book carefully.
M
Mructions before
. Keep the air filter clean. (See instructions on page 5.)
apptiance.
When using this appliance, always exercise basic safety precautions, including the following:
G For most efficient cooling, keep the vent control in the CLOSED position except when you want to exhaust air, smoke or odors from the room.
It is intended to help you operate and maintain your new air conditioner properly.
ik intended purpose as
G Use this appliance only for
describd in this Use and Care Guide.
Keep it handy for answers to your questions.
c Don’t let the room get too hot. Whenever possible, turn the unit on before the room heats up. When heat is “stored up” in walls, furniture, rugs and draperies, your air conditioner takes longer to produce the desired comfort condition.
If you don’t understand something or need more help, write (include your phone number): Consumer Affairs GE Appliances Appliance Park Louisville, KY 40225
Insbllation Instructions before it is used. See grounding instructions on page 7.
G Never unplug your air conditioner by pulling on the power cord. Always grip plug
G Keep windows and doors closed. Cool, dry air escapes when they’re open.
firdy and pull straight out from the receptacle.
Write down the model and serial numbers.
G Keep furnace floor registers and cold air returns closed. Cold air can easily escape through them.
G Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
You’ll find them on a label behind the air discharge louvers. They’ll be easier to read if you shine a flashlight on them or remove the front grille. (See page 5.)
G Don’t let drapes or furniture block the front of the unit and restrict air flow when it is operating.
G It’s best to operate your air conditioner at high speed during extremely hot weather.
These numbers are also on the Consumer Product Ownership Registration Card that came with your air conditioner. Before sending in this card, please write these numbers here:
G Keep the outdoor condenser coil clean. (See page 5.)
SAW
G Turn the air conditioner off before vacations or extended absences from home.
Use these numbers in any correspondence or service calls concerning your air conditioner.
dam~ed air conditioner . . .
Immediately contact the dealer (or builder) that sold you the air conditioner.
Save time and money. Before you request service . . .
Check the Problem Solver on page 6. It lists causes of minor operating problems that you can correct yourself.
Model Number · Serial Number


Controk
/,


D
FAN COOL
SELECTOR
THERMOSTAT
Selector
Switih
Thermostat Control
Ventilation Control
OFF turns air conditioner off.
When you turn the Thermostat Control to the desired setting, the thermostat will automatically control
The vent door in your air conditioner is closed when the slide switch is to the
permits low fan speed operation without cooling. *MED FAN permits medium fan speed operation without cooling. *HIGH FAN permits high fan speed operation without cooling.
right. When the vent is closed,
the temperature of the indoor air. The higher the number selected, the cooler the indoor air will be.
onl~the air inside the room can be circulated and conditioned. Sliding the knob to the left opens the vent door, allowing a small amount of indoor air to be exhausted from the room.
Swikh (on models so equipped)
*For FAN operation, Energy Saver
Setting the Ventilation Control at OPEN lets room air be exhausted to the outside. This is helpful in
LOW COOL permits cooling with low fan speed operation. MED COOL permits cooling with medium fan speed operation. HIGH COOL permits cooling with high fan speed operation.
removing stale air, smoke or odors from the-room, and
perrnim outdoor air to enter through normal openings in the house. However, cooling effectiveness is reduced when this control is set at OPEN, so we
su~est you don’t keep it there
long— especially in hot, humid weather.
The Energy Saver Switch controls the fan operation. When it’s in
will circulate room air continuously. When it’s in the SAVE position, the fan will automatically cycle on and off with the compressor.
NOR-MAL position, the fan

Your Air Conditioner
For quieter operation
To adjust air direction

Three separate banks of
up-and- down air direction louvers are controlled by fingertip pressure on the louvers. They regulate air discharge upward, downward or straight out.
OFF ON m
During the cooler evening hours, we recommend that you set the Selector Switch at LOW COOL for very quiet operation and the Thermostat Control at mid-range (5 or 6). Set the Ventilation Control at CLOSED and the Energy Saver Switch* at NORMAL or SAVE position.
Some models have a
Circulaire Switch. For
fixed side-to-side air direction, slide the
Circulaire Switch to ON until the desired air direction is
obbined, then move it to OFF. For continuous side-to-side air circulation, set the
Circulaire Switch to ON and leave it there.
For greatest economy and best performance, we suggest you set the Selector Switch at HIGH COOL in extremely hot weather.

Other models have two separate banks of side-to-side air direction louvers with separate tabs to let you direct discharged air to the right, to the left, or straight ahead.
*On models so equipped
Controb(continued) · Up and down · Side to side


Afier cleaning, replace the grille. Use a magnetic-tipped screwdriver to attach the grille with the two screws removed in step 2.

Turn air conditioner off and remove plug from wall outlet before cleaning.

Wipe front grille with a clean cloth lightly dampened with mild liquid
dishwashing detergent. Wash cabinet with mild soap or detergent and lukewarm water.
To replace the inlet baffle, align the large tabs on the baffle with the slots on the frame and push straight on
These coils on the weather side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere. If extremely soiled, they may need to
light dust. Wash the filter. cleaner side up, under gently flowing water to wash out accumulated dust and lint. If the filter is very dirty, use a mild household detergent in the wash water. Let the
until the baffle snaps into place.
be steam cleaned, a service available through your GE service outlet.
filter dry thoroughly before replacing it.
Front Grille Removal
The air filter behind the inlet grille should be washed at least every 30 days or as
The front grille can be removed for more thorough cleaning or to make the model and serial numbers easier to read.
often as it needs cleaning.

To remove the filter, grasp the upper part of the inlet baffle and pull toward you. Then pull the filter up and out.

washerhead screws that hold the grille to the frame.


Vou need more help.. call, toll free: GE Answer Center
800.6262000 consumer information service
If You Need Service
To obtain service, see your warranty on the back page of this book. We’re proud of our service and want you to be pleased. If for some reason you are not happy with the service you receive, here are three steps to follow for further help. FIRST, contact the people who serviced your appliance. Explain
why you are not pleased. In most FINALLY, if your problem is still cases, this will solve the problem. not resolved, write:
NEXT, if you are still not pleased, Major Appliance write all the details-including Consumer Action Panel
Manager, Consumer Relations GE Appliances Appliance Park Louisville, Kentucky 40225


Imtructiom
~ave these instructions with the appliance. OWNER:
Wep these instructions for future use.
Safetv— The
It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground
Dower cord on these models IMPORTANT...
~ 230/208-volt perpendicular, tandem or large tandem type plug that mates
“ Please Read Carefully.
resDectivelv with a 230/208-volt
exis@.
outlet. These types of outlets are available at most hardware stores. appliance must be properly grounded.
etinsion cords not recommended
For personal safety, this
Q@
Because of potential safety hazards under certain conditions, we

stron~y recommend against the use of an extension cord. However, if you
models require their own single branch circuit supplying 230/208-volt
stifl elect to use an extension cord, it is absolutely necessary that it be a
a.c., protected with a time delay fuse or circuit breaker. This is recommended for best performance and to prevent overloading house wiring circuits, which could cause a possible fire hazard from overheating wires.
UL listed 3-wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equal to or greater than the branch circuit size shown on the rating nameplate of the appliance.
REQUIRES 20 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER
PROTEUION

230/208-VOLT MATCHING TANDEM TYPE WALL OUTLET LINE CORD PLUG
OR CIRCUIT BREAKER PROTECTION
mm

(’ G
TANOEM TYPE WALL OUTLET LINE CORO PLUG
REQUIRES 30 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER

has · PROTE~lON

Imtructiom (continued)

Washer Head Locking Screw
‘oar:et

R:tainer
Seal—Bottom Rail to Unit

\
:

yj;;:;/
\
;?,
Tf
;?
,~,
T?
m Q
‘b Type D Bolt
~’
Qty-2 Qty-3 Qty-4 Qty-2 Qty-2
G Hand saw . Hammer
should be secured to firm wood, masonry or metal.
G Large blade-type screwdriver
~’
G Adjustable wrench or pliers . Rule or tape measure
G Concrete saw (if installing through a masonry wall)
t 32” to 38”
* .
201/2” min.
kife or razor blade
G Standard double-hung window with actual opening width of 32” to 38”.

G All the tools above (except
bife or razor blade) plus
G Clear, vertical opening of 201/2”
G Magnetic stud finder (optional) minimum from bottom of sash to
G Tin snips (optional) stool.




112” clearance below the window stool is required. If the storm window frame does not allow this clearance, attach a 1
2~wide strip of wood along the entire length of the window opening, flush with the back side of the stool, or remove the storm window for the air conditioning season.
to top angle as shown.
‘-~


201/2” min.
‘~’


./

Storm Window Frame or Other Obstruction



by holding with left hand while-pulling on handle at bottom front of unit. Be careful of sharp edges on the coil fins. If your unit has corrugated packing material inside the cabinet, it must be removed. Do not remove the foam pads inside the cabinet.
Slide chassis from cabinet
Wneh.
>:1:%:
table.

~;,.~:]
filler panel into the panel retainer on the side of the cabinet as shown above. Do both sides,
Filler Panel 4. Insert two Type A screws into holes in the top leg of the filler panel frame. Do not tighten—legs should slide easily.
N~ intended for lifting the unit. It is only for sliding the chassis out of the cabinet for cleaning or maintenance.

bcate Cabinet in Window.
hck and Sash Seal.


fit window width and insert into space between upper and lower
sashe;.

previously marked, as-shown. Hand tighten only—some adjustment may be required later.


bottom rail flush with front edge of rail and in

conmct with side seals.
Sfide~assis into Cabinet.
Be sure handle at bottom of unit is up. Then
lifi chassis and carefully slide it into cabinet. Do not push on controls or finned coils. Make sure chassis is firmly seated toward rear of cabinet.
Panek.
Bracke&.



%
p I
QQ ‘
If dial plate has a protective film, peel the film off carefully. Do not scratch the surface of the plate.
LEFT
0 Sill Angle Bracket” *(1 required for each support bracket)
Pront Grille.
(a) Remove inlet baffle (see page 5). (b) Attach front grille to unit (see page 11, step
6b). (c)
irdet baffle (see page 5).


Imbllation
c The cabinet may be installed through the wall in both existing buildings and new construction.
s The side louvers must project on the outdoor side of the wall.
G The room side of the cabinet must provided in cabinet for top rail and side retainers not used in this project into the room at least 1“ from the finished wall. installation.


. The cabinet must be installed level from side to side and with a 3/8” tilt from front to rear. 3. Install Cabinet in Wall.
wall opening.

Took Required See page 8.


Cabinet.

G 10 #10 wood screws, 1“ long
Be sure handle at bottom of unit is up. Then lift chassis and carefully slide it into cabinet. Do not push on controls or finned coils. Make sure chassis is firmly seated toward rear of cabinet.
G 1 tube high grade caulking 2
!. Secure bottom rail to wood
compound f .
rame with two 1“
locall].
G Lintel, if required, to support
bricks or blocks above
op~ning. 3. Secure cabinet to wooden frame with ten #10 1“ long screws or nails 1.
ODeninp. obtained locally. If frame is oversize,
. 1. Determine size of opening. Measure width and height of
use shims to eliminate distortion.
c~binet and add 1/8” to each dimension.

See page 10, step 9.

(a) Remove inlet baffle from front grille (see page 5).

~revent moisture from getting
thr;ugh to the interior wall. Use of flashing (a piece of aluminum or galvanized steel available at most hardware
a screw in this location, remove and discard screw to support the weight of the air from getting into interior walls. before installing front grille. conditioner. Add metal flashing over bottom of frame opening and
(b) Attach front grille to unit with two Type E hex
roomside projection of cabinet, if desired.
washerhead screws as shown above.
UP on sides to reduce the possibility of condensate entering
the area between the inner and (c)
ReinsMl inlet baffle (see page 5). outer wall.

WARRANTY Save proof of original purchase date such as your sales slip or
cancelled check to establish warranty period,
warrantv is extended to the original purchaser and any succeeding owner for products purchased for use in the 48 mainland states, Hawaii and Washington,
For one year from date of original purchase, we will provide, free of charge,
pafls and service labor in your home to repair or replace any part of the room air conditioner that fails because of a manufacturing defect.
D.C. In Alaska the warranty is the same except that it is LIMITED because you must pay to ship the product to the service shop or for the service technician’s travel costs to your home.
For five years from the date of original purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the
All warranty service will be provided by our Factory Service Centers or by our authorized Customer
Care” servicers during normal working hours.
compresso~ condenser, evaporator and all connecting tubing) that fails because of a manufacturing defect.
Look in the White or Yellow Pages of your telephone directory for GENERAL ELECTRIC COMPANY, GENERAL ELECTRIC FACTORY SERVICE, GENERAL
%r each of the above warranties: Transportation expense to and from a service shop and shop service labor if required will be free of charge.
HOTPOINT FACTORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE@ SERVICE.
N~ COVERED
G Service trips to teach you how to use the product. Read your Use and Care material. If you then have any questions about operating the product, please contact your dealer or our Consumer Affairs office at the address below, or call, toll free: GE Answer
G Improper installation. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
. Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
G Failure due to corrosion on models not corrosion-protected.
. Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
Cente@ 800.626.2000 consumer information service
G Replacement of fuses or resetting of circuit breakers.
G In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician.
NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
To know what your legal rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General.
If further help is needed concerning this warranty, write: Manager—Consumer Affairs, GE Appliances, Louisville, KY 40225
Pan No.
AES23 Pub.
AES15
No. 49-7220
AED18
10-89 .
This · sealed · mfrigemting system (the
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| AIR CONDITIONER DOES N~ OPERATE | G Not plugged in. Plug may have been bumped loose by vacuum cleaner or furniture. . If plugged in, fuse could have blown or circuit breaker may have tripped. . Curtains, blinds or furniture blocking front of air conditioner will restrict airflow. G Thermostat Control may not be set high enough. Turn control to a higher number. Highest setting should provide maximum cooling. When Energy Saver Switch (on some models) is set at SAVE, temperature range in room will vary more. G Air filter dirty, should be cleaned at least every 30 days. See instructions on page 5. G Room may have been very hot when air conditioner was first turned on. Allow time for it to cool down. G Cold air maybe escaping through open furnace floor registers and cold air returns. G Ventilation control maybe set at open position, allowing hot outside air to enter the room. G Cooling coils have iced up. To melt ice, set the Selector Switch to HIGH FAN and the Thermostat Control to a lower number. | p.6 | |
| AIR CONDITIONER “DOES NOT COOL AS IT SHOULD” | p.6 | ||
| OPERATING SOUNDS | G Thermostat click, a metallic sound, maybe heard when compressor cycles on and off. This is normal. G Fan runs continuously when Selector Switch is in Cool or Fan position. This is normal. When Energy Saver Switch (on some models) is set at SAVE, fan cycles on and off with compressor. G Excess water may overflow in extremely hot and humid weather. This is normal. | p.6 | |
| WATER DRIPPING OUTSIDE WATER DRIPPING INSIDE | p.6 | ||
| WATER DRIPPING OUTSIDE WATER DRIPPING INSIDE | G Air conditioner must be installed with the specified tilt to the outside for proper water disposal. | p.6 | |
| WATER IN BASE PAN (ON OUTDOOR SIDE) | G This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas. Moisture removed from indoor air drains to rear of cabinet where it is picked up by a fan ring and thrown against the outdoor condenser coil. | p.6 |
Owners and our team usually reply within a day — and your question helps the next person too.