Air Conditioners
Room
Owner’s Manual and Installation Instructions
AEN10* AEN12*
Care and Cleaning Air Filter .............................................................6 Outdoor Coils ..................................................6
Climatiseur
Troubleshooting Tips ................. 14 Normal Operating Sounds ....................14
Manuel d’utilisation et instructions d’installation
Consumer Support Consumer Support Back Cover Ownership Registration for Customers in Canada only 15, 16 Warranty for Customers in Canada 17 Warranty for Customers in the U.S.A 18
La section française commence à la page 19
de aire
y instrucciones de
instalación
La sección en español empieza en la página 35
*EnErgy Star® labeled product
As an EnErgy Star® partner, GE has determined that this product meets the EnErgy Star® guidelines for energy efficiency.
Write the model and serial numbers here:
Find these numbers on a label on the side of the air conditioner.
Model # · Serial #

n Use this appliance only for its intended purpose as described in this Owner’s Manual.
n Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning.
n This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
n Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
n For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
n Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
n All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
n These R410A air conditioning systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
n If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

RISK OF FIRE. Could cause serious injury or death.
READ AND FOLLOW THIS SAFETY INFORmATION CAREFULLY.

Features and appearance will vary. Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
The display always shows the room temperature except when setting the Set temperature or the Delay timer.

Light indicates the unit is in the temperature or delay time Set mode.

Remote Control

Power Pad Turns air conditioner on and off. When turned on, the display will show the room temperature.
Mode Pad Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
Display Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
Delay Pads Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the + pad on the remote control. Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
Temp Increase /DecreasePads Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.
Delay Timer Increase (+) /Decrease(–)
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the + pad on the remote control. Use the Increase / Decrease pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.
Pads Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer (+). The Set light will turn on while setting.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
Fan Speed Pads Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may need to set a new time if desired.

Cool Mode Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase / Decrease pads to set the desired temperature between 64°F and 86°F in 1°F increments.
Cooling Descriptions For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
Do Not Operate in Freezing Outdoor Conditions This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Controls the fan. ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor cycles on and off.
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

Use the levers to adjust the air direction left and right.
Fingertip pressure on the louver banks adjusts the air direction up or down.
n To ensure proper operation, aim the remote control at the signal receiver on the air conditioner. n Make sure nothing is between the air conditioner
n The remote control signal has a range of
up to 20 feet. n Make sure batteries are fresh and installed
correctly as indicated on the remote control. n Remote contains a magnet allowing it to attach
and the remote control that could block the signal.
to metal surfaces.

Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45° position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

1 Remove the battery cover by sliding it according to the arrow direction. 2 Insert new batteries, making sure that the (+) and (–) of battery are installed correctly. 3 Reattach the cover by sliding it back into position.

n Use 2 “AAA” (1.5 volt) alkaline batteries. Do not use rechargeable batteries.
n Remove the batteries from the remote control if the system is not going to be used for a long time.
n Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.

Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
CAUTION: Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Do not change the plug on the power cord of this air conditioner. Aluminum house wiring may present special problems—consult a qualified electrician. If the sill support bolts do not contact the window sill, or if you have a window without a sill, you must order accessory kit RAK87 to properly install this air conditioner. Call 800.626.2002 or visit GEAppliances.com.
Read these instructions completely and carefully.
ELECTRICAL REQUIREMENTS
Ruler or tape measure Pencil
Some models require a 115/120-volt AC,
60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Level Scissors or knife
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Some models require 230/208-volt AC,
protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Phillips head screwdriver · Adjustable wrench · Flat-blade screwdriver



REMOVE THE AIR CONDITIONER
Remove and save the 2 screws from the lower sides of the front grille.
B
Grasp the lower corners of the grille while pressing in on the case sides with your finger tips. Pull out to release and lift it up. NOTE: Do not pull the bottom edge toward you more than 3″ or you may damage the tabs of the grille.
16.4” min.
25.25″ to 38″ (With accordion panels)
Remove the ground screw from each side of the case. Keep them in a safe location. NOTE: Be sure to save these screws. You will need them later in the installation.
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill. WOOD PIECES – WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the vinyl frame. Attach securely with nails or screws provided by the installer.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. Do not pull or lift on the styrofoam discharge area.
1/2″ higher than vinyl frame (on some windows)
pull or lift in this
1/2″ higher than storm window frame
to the unit may


4 ATTACH THE TOP MOUNTING RAIL SEAL STRIP Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top maounting rail, along the front edge. Allow the seal strip to overlap 3/8” on each end.

Slide the left and right accordion panels into the top and bottom mounting rails.
Attach the accordion panels to the case using 3 Type A screws on each side.
Attach the top mounting rail onto the top of the case with 3 Type B screws.


INSTALL THE CASE IN THE WINDOW
(CONT.) Secure the case to the window sill by using 3
Open the window and mark the centerline of
the window sill. Carefully place the case on the window stool
and align the center mark on the bottom front with the centerline of the sill. Pull the window down behind the top mounting
rail.
track. Attach them on each side to the window sash and the window sill using 4 Type C screws.
movement of the accordion panels is restricted. Select the position that will place the sill supports near the outermost point on the sill. Place the short side of the sill supports, on the case bottom, toward the window. Attach the sill supports to the case track hole in relation to the selected position using 2 Type B screws in each support.
Long side of sill supports
E
Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside. Use a level; no more than 1/2 bubble will be the correct case slant to the outside.


A CAUTION: To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the support bracket to the window side jam.
Replace the 2 ground screws removed earlier, one on each side of the case.
Attach the support bracket with one Type C screw.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Attach the front grille to the case by inserting the tabs on the grille into the slots on the front top of the case. Push the grille in.
IN THE CASE
Secure the front grille to the case by replacing the 2 screws removed earlier. Press on the top of the grille to help with side screw installation.
Slide the air conditioner into the case by the base pan. Do not push on the controls, styrofoam air discharge housing or the finned coils. Make sure the air conditioner is firmly seated.
Do not press on these areas— damage to the unit may result
Vinyl · Wood · Base Pan

Troubleshooting Tips.
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The air filter is dirty. • Clean the filter at least every 30 days. See the Care and Cleaning section.
The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping. • Check for open furnace registers and cold air returns.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
The remote control The batteries are inserted • Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. • Replace the batteries.
Water drips outside Hot, humid weather. • This is normal.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air • This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
n You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
n Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
n The fan may run even when the compressor does not.
n You may hear the thermostat click when the compressor cycles on and off.




All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, visit us on-line at GEAppliances.com, or call 800.GE.CARES (800.432.2737). Have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
What Is Not Covered:
n Service trips to your home to teach you how to
n Replacement of house fuses or resetting of circuit
use the product.
breakers.
n Improper installation, delivery or maintenance. If you
n Failure due to corrosion on models not corrosion-
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Failure of the product resulting from modifications to
n Incidental or consequential damage caused by possible
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
n Damage caused after delivery.
n In commercial locations, labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 1.800.561.3344. Please have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, mabe will also provide, free of charge, all labor and original purchase related service to replace the defective part.
What Is Not Covered:
n Service trips to your home to teach you how to
n Replacement of house fuses or resetting of circuit
use the product.
breakers.
n Improper installation, delivery or maintenance. If you
n Failure due to corrosion on models not corrosion-
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Failure of the product resulting from modifications to
n Incidental or consequential damage caused by possible
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
n Damage caused after delivery.
n In commercial locations, labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased in Canada for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from province to province. To know what your legal rights are in your province, consult your local or provincial consumer affairs office.
Burlington, Ontario
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | p.13 | ||
| Air conditioner does not start | p.13 | ||
| Air conditioner does not cool as it should | Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • On models with touch pads: In the Cool mode, press the not be set correctly. Decrease pad. • On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Care and Cleaning section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace registers and cold air returns. Cooling coils have iced up. • See “Air conditioner freezing up” below. | p.13 | |
| Air conditioner freezing up | Ice blocks the air flow • On models with control knobs, set the mode control at and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2. from cooling the room. • On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. | p.13 | |
| The remote control is not working | The batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. | p.13 | |
| Water drips outside | Hot, humid weather. • This is normal. | p.13 | |
| Water drips indoors | The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. | p.13 | |
| Water collects in base pan | Moisture removed from air • This is normal for a short period in areas with little and drains into base pan. humidity; normal for a longer period in very humid areas. | p.13 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.