EN
GE logo
Official user manual

GE 82-POE

226 pages·2.8 MB·Switch·PDF·ENDEFRITNLJA
GE 82-POE
Table of Contents 163 sections Package Contents · Product Description · High Performance Wire-Speed Switching · Cost-effective solution with SNMP monitor for Network deployment · … ShowHide
Package Contentsp.6Product Descriptionp.6High Performance Wire-Speed Switchingp.6Cost-effective solution with SNMP monitor for Network deploymentp.7Remote and Centralize Management installationp.7Powerful Securityp.7Power over Ethernet of GE-DS-82-PoEp.8How to Use this Manualp.8Product Featuresp.8Physical Portp.8Product Specificationsp.11Hardware Descriptionp.15Switch Front Panelp.15LED Indicationsp.16Switch Rear Panelp.18Switch Installationp.20Desktop/Shelf Installationp.20Rack-mount Installationp.21SFP Transceiver Installationp.22Summaryp.27Requirementsp.27Management Access Overviewp.28Web Browser Managementp.29Web Browser Setupp.30SNMP-Based Network Managementp.32The Administration Consolep.32Direct Accessp.33Protocolsp.34Virtual Terminal Protocolsp.34Telnet Setupp.34SNMP Protocolp.36Management Architecturep.36About Web-based Managementp.37Requirementsp.38Logging on to the Switchp.39Main Web Pagep.40Panel Displayp.40Main Menup.41Systemp.42System Informationp.42IP Configurationp.45SNMP Configurationp.47SNMPv3 Viewp.52Firmware Upgradep.55Configuration Backupp.57Factory Defaultp.59Syslog Settingp.60Port Configurationp.60Port Statusp.63Port Statisticsp.63Port Snifferp.65Protected Portp.67VLAN Configurationp.68VLAN Overviewp.68Static VLAN Configurationp.71Port-Based VLANp.72802.1Q VLANp.75802.1Q VLANp.80GVRP VLANp.84GVRP Settingp.84Rapid Spanning Treep.87Theoryp.87Illustration of STPp.90STP Parametersp.92RSTP System Configurationp.93Port Configurationp.96Trunkingp.98Aggregator Settingp.99Aggregator Informationp.100State Activityp.104Forwarding and Filteringp.105Dynamic MAC Tablep.105Static MAC Tablep.106MAC Filteringp.107IGMP Snoopingp.109Theoryp.109IGMP Configurationp.113QoS Configurationp.114Understand QOSp.114QoS Configurationp.115TOS/DSCPp.117Access Control Listp.120MAC Limitp.125MAC Limit Configurationp.125MAC Limit Port Statusp.126802.1X Configurationp.127Understanding IEEE 802.1X Port-Based Authenticationp.127System Configurationp.131802.1x Port Configurationp.132Misc Configurationp.134Power Over Ethernetp.135Power over Ethernet Powered Devicep.135Power Managementp.135DHCP Relay and Option 82p.139LLDPp.140Login in to the Console Interfacep.143Configure IP addressp.145Commands Levelp.147Operation Noticep.149Command Line Editingp.150Command Helpp.150System Commandsp.150Switch Static Configurationp.151Port Configuration and show statusp.151Trunk Configurationp.155Trunking Commandsp.155LACP Commandsp.157VLAN Configurationp.159Virtual LANsp.159VLAN Mode: Port-basedp.160Advanced 802.1Q VLAN Configurationp.161Misc Configurationp.169Administration Configurationp.171Change Username / Passwordp.171IP Configurationp.172Reboot switchp.173Reset to Defaultp.173TFTP Update Firmwarep.174Restore Configure Filep.174Backup Configure Filep.175MAC limitp.176Port Mirroring Configurationp.177Quality of Servicep.178QoS Configurationp.178Per Port Priorityp.180MAC Address Configurationp.181STP/RSTP Commandsp.183SNMPp.188System Optionsp.188Community Stringsp.190Trap Managersp.191IGMPp.192802.1x Protocolp.194Access Control Listp.198Ipv4 ACL commandsp.198Non-Ipv4 ACL commandsp.201Bindingp.203SIP/SMAC binding commandsp.203Power over Ethernet Commands (GE DS-82-PoE)p.205Display System PoE statusp.205Configure PoE Over Temperature Protectionp.207Configure PoE - Systemp.207Configure PoE -- Portp.209Address Tablep.213Learningp.213Forwarding & Filteringp.213Store-and-Forwardp.214Auto-Negotiationp.214What is PoE?p.215PoE System Architecturep.216How Power is Transferred Through the Cablep.216The PoE Provision Processp.218Stages of powering up a PoE linkp.218Line Detectionp.219Classificationp.219Start-upp.219Operationp.219Power Overloadsp.220Power Disconnection Scenariosp.220DC Disconnectp.220AC Disconnectp.220Switch's RJ-45 Pin Assignmentsp.22310/100Mbps, 10/100Base-TXp.224
Page 1 of the GE 82-POE user manual — GE Security
Page 1 · click to enlarge
Page 1

GE Security

  • P/N 1069182
  • REV 1.0
  • ISS 23FEB10
Page 2 of the GE 82-POE user manual
Page 2 · click to enlarge
Page 2

Copyright © 2010 GE Security, Inc.

This document may not be copied in whole or in part or otherwise reproduced without prior written consent from GE Security, Inc., except where specifically permitted under US and international copyright law.

Disclaimer The information in this document is subject to change without notice. GE Security, Inc. (“GE Security”) assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.gesecurity.com

This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental.

Trademarks and patents GE and the GE monogram are trademarks of General Electric Company.

Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.

Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at www.gesecurity.com

FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Manufacturer GE Security, Inc.

HQ and regulatory responsibilityGE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202, USA

EU authorized manufacturing representative:

GE Security B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands

2002/96/EC (WEEE directive)Products marked with this symbol cannot be disposed of as

unsorted municipal waste in the European Union. For proper recycling, return this product to

your local supplier upon the purchase of equivalent new equipment, or dispose of it at

designated collection points. For more information see: www.recyclethis.info

Contact information For contact information see our Web site: www.gesecurity.com

For contact information see our Web site: www.gesecurity.eu

Regulatory information N4131 · European Union directives

Page 3 of the GE 82-POE user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Package Contentsp.6Product Descriptionp.6High Performance Wire-Speed Switchingp.6Cost-effective solution with SNMP monitor for Network deploymentp.7Remote and Centralize Management installationp.7Powerful Securityp.7Power over Ethernet of GE-DS-82-PoEp.8How to Use this Manualp.8Product Featuresp.8Physical Portp.8Product Specificationsp.11Hardware Descriptionp.15Switch Front Panelp.15LED Indicationsp.16Switch Rear Panelp.18Switch Installationp.20Desktop/Shelf Installationp.20Rack-mount Installationp.21SFP Transceiver Installationp.22Summaryp.27Requirementsp.27Management Access Overviewp.28Web Browser Managementp.29Web Browser Setupp.30SNMP-Based Network Managementp.32The Administration Consolep.32Direct Accessp.33Protocolsp.34Virtual Terminal Protocolsp.34Telnet Setupp.34SNMP Protocolp.36Management Architecturep.36About Web-based Managementp.37Requirementsp.38Logging on to the Switchp.39Main Web Pagep.40Panel Displayp.40Main Menup.41Systemp.42System Informationp.42IP Configurationp.45SNMP Configurationp.47SNMPv3 Viewp.52Firmware Upgradep.55Configuration Backupp.57Factory Defaultp.59Syslog Settingp.60Port Configurationp.60Port Statusp.63Port Statisticsp.63Port Snifferp.65Protected Portp.67VLAN Configurationp.68VLAN Overviewp.68Static VLAN Configurationp.71Port-Based VLANp.72802.1Q VLANp.75802.1Q VLANp.80GVRP VLANp.84GVRP Settingp.84Rapid Spanning Treep.87Theoryp.87Illustration of STPp.90STP Parametersp.92RSTP System Configurationp.93Port Configurationp.96Trunkingp.98Aggregator Settingp.99Aggregator Informationp.100State Activityp.104Forwarding and Filteringp.105Dynamic MAC Tablep.105Static MAC Tablep.106MAC Filteringp.107IGMP Snoopingp.109Theoryp.109IGMP Configurationp.113QoS Configurationp.114Understand QOSp.114QoS Configurationp.115TOS/DSCPp.117Access Control Listp.120MAC Limitp.125MAC Limit Configurationp.125MAC Limit Port Statusp.126802.1X Configurationp.127Understanding IEEE 802.1X Port-Based Authenticationp.127System Configurationp.131802.1x Port Configurationp.132Misc Configurationp.134Power Over Ethernetp.135Power over Ethernet Powered Devicep.135Power Managementp.135DHCP Relay and Option 82p.139LLDPp.140Login in to the Console Interfacep.143Configure IP addressp.145Commands Levelp.147Operation Noticep.149Command Line Editingp.150Command Helpp.150System Commandsp.150Switch Static Configurationp.151Port Configuration and show statusp.151Trunk Configurationp.155Trunking Commandsp.155LACP Commandsp.157VLAN Configurationp.159Virtual LANsp.159VLAN Mode: Port-basedp.160Advanced 802.1Q VLAN Configurationp.161Misc Configurationp.169Administration Configurationp.171Change Username / Passwordp.171IP Configurationp.172Reboot switchp.173Reset to Defaultp.173TFTP Update Firmwarep.174Restore Configure Filep.174Backup Configure Filep.175MAC limitp.176Port Mirroring Configurationp.177Quality of Servicep.178QoS Configurationp.178Per Port Priorityp.180MAC Address Configurationp.181STP/RSTP Commandsp.183SNMPp.188System Optionsp.188Community Stringsp.190Trap Managersp.191IGMPp.192802.1x Protocolp.194Access Control Listp.198Ipv4 ACL commandsp.198Non-Ipv4 ACL commandsp.201Bindingp.203SIP/SMAC binding commandsp.203Power over Ethernet Commands (GE DS-82-PoE)p.205Display System PoE statusp.205Configure PoE Over Temperature Protectionp.207Configure PoE - Systemp.207Configure PoE -- Portp.209Address Tablep.213Learningp.213Forwarding & Filteringp.213Store-and-Forwardp.214Auto-Negotiationp.214What is PoE?p.215PoE System Architecturep.216How Power is Transferred Through the Cablep.216The PoE Provision Processp.218Stages of powering up a PoE linkp.218Line Detectionp.219Classificationp.219Start-upp.219Operationp.219Power Overloadsp.220Power Disconnection Scenariosp.220DC Disconnectp.220AC Disconnectp.220Switch's RJ-45 Pin Assignmentsp.22310/100Mbps, 10/100Base-TXp.224
Page 4 of the GE 82-POE user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Package Contentsp.6Product Descriptionp.6High Performance Wire-Speed Switchingp.6Cost-effective solution with SNMP monitor for Network deploymentp.7Remote and Centralize Management installationp.7Powerful Securityp.7Power over Ethernet of GE-DS-82-PoEp.8How to Use this Manualp.8Product Featuresp.8Physical Portp.8Product Specificationsp.11Hardware Descriptionp.15Switch Front Panelp.15LED Indicationsp.16Switch Rear Panelp.18Switch Installationp.20Desktop/Shelf Installationp.20Rack-mount Installationp.21SFP Transceiver Installationp.22Summaryp.27Requirementsp.27Management Access Overviewp.28Web Browser Managementp.29Web Browser Setupp.30SNMP-Based Network Managementp.32The Administration Consolep.32Direct Accessp.33Protocolsp.34Virtual Terminal Protocolsp.34Telnet Setupp.34SNMP Protocolp.36Management Architecturep.36About Web-based Managementp.37Requirementsp.38Logging on to the Switchp.39Main Web Pagep.40Panel Displayp.40Main Menup.41Systemp.42System Informationp.42IP Configurationp.45SNMP Configurationp.47SNMPv3 Viewp.52Firmware Upgradep.55Configuration Backupp.57Factory Defaultp.59Syslog Settingp.60Port Configurationp.60Port Statusp.63Port Statisticsp.63Port Snifferp.65Protected Portp.67VLAN Configurationp.68VLAN Overviewp.68Static VLAN Configurationp.71Port-Based VLANp.72802.1Q VLANp.75802.1Q VLANp.80GVRP VLANp.84GVRP Settingp.84Rapid Spanning Treep.87Theoryp.87Illustration of STPp.90STP Parametersp.92RSTP System Configurationp.93Port Configurationp.96Trunkingp.98Aggregator Settingp.99Aggregator Informationp.100State Activityp.104Forwarding and Filteringp.105Dynamic MAC Tablep.105Static MAC Tablep.106MAC Filteringp.107IGMP Snoopingp.109Theoryp.109IGMP Configurationp.113QoS Configurationp.114Understand QOSp.114QoS Configurationp.115TOS/DSCPp.117Access Control Listp.120MAC Limitp.125MAC Limit Configurationp.125MAC Limit Port Statusp.126802.1X Configurationp.127Understanding IEEE 802.1X Port-Based Authenticationp.127System Configurationp.131802.1x Port Configurationp.132Misc Configurationp.134Power Over Ethernetp.135Power over Ethernet Powered Devicep.135Power Managementp.135DHCP Relay and Option 82p.139LLDPp.140Login in to the Console Interfacep.143Configure IP addressp.145Commands Levelp.147Operation Noticep.149Command Line Editingp.150Command Helpp.150System Commandsp.150Switch Static Configurationp.151Port Configuration and show statusp.151Trunk Configurationp.155Trunking Commandsp.155LACP Commandsp.157VLAN Configurationp.159Virtual LANsp.159VLAN Mode: Port-basedp.160Advanced 802.1Q VLAN Configurationp.161Misc Configurationp.169Administration Configurationp.171Change Username / Passwordp.171IP Configurationp.172Reboot switchp.173Reset to Defaultp.173TFTP Update Firmwarep.174Restore Configure Filep.174Backup Configure Filep.175MAC limitp.176Port Mirroring Configurationp.177Quality of Servicep.178QoS Configurationp.178Per Port Priorityp.180MAC Address Configurationp.181STP/RSTP Commandsp.183SNMPp.188System Optionsp.188Community Stringsp.190Trap Managersp.191IGMPp.192802.1x Protocolp.194Access Control Listp.198Ipv4 ACL commandsp.198Non-Ipv4 ACL commandsp.201Bindingp.203SIP/SMAC binding commandsp.203Power over Ethernet Commands (GE DS-82-PoE)p.205Display System PoE statusp.205Configure PoE Over Temperature Protectionp.207Configure PoE - Systemp.207Configure PoE -- Portp.209Address Tablep.213Learningp.213Forwarding & Filteringp.213Store-and-Forwardp.214Auto-Negotiationp.214What is PoE?p.215PoE System Architecturep.216How Power is Transferred Through the Cablep.216The PoE Provision Processp.218Stages of powering up a PoE linkp.218Line Detectionp.219Classificationp.219Start-upp.219Operationp.219Power Overloadsp.220Power Disconnection Scenariosp.220DC Disconnectp.220AC Disconnectp.220Switch's RJ-45 Pin Assignmentsp.22310/100Mbps, 10/100Base-TXp.224
Page 5 of the GE 82-POE user manual — Chapter 1 Introduction
Page 5 · click to enlarge
Page 5

Chapter 1 Introduction

GE 82-POE — Chapter 1 Introduction diagram (page 5)
Fig. 1 · Chapter 1 Introduction

The GE Security GE-DS-82 and GE-DS-82-PoE are Ethernet Managed Switches with 8 10/100Mbps ports and 2 Gigabit TP/SFP fiber optical combo connective ability with robust layer 2 features. The description of these models is below:

GE-DS-828-Port 10/100Base-TX + 2-Port Gigabit TP/SFP Combo Managed Switch
GE-DS-82-PoE8-Port 10/100Base-TX + 2-Port Gigabit TP/SFP Managed PoE Switch
Page 6 of the GE 82-POE user manual — High Performance Wire-Speed Switching
Page 6 · click to enlarge
Page 6
Chapter 1Introduction

Package Contents

Open the Managed Switch box and carefully unpack it. The box should contain the following items:

The Managed Switch x1

User’s manual CD x1

19” Rack mount accessory kit x1

If any of these items are missing or damaged, please contact your dealer immediately.

Product Description

High Performance Wire-Speed Switching

The GE Security GE-DS-82 Series of Managed Switches offers 8 Ethernet ports with 2 Gigabit TP / SFP combo ports. The type 8 Fast Ethernet ports of the GE-DS-82 and GE- DS-82-PoE are 10 / 100Base-TX copper (RJ-45). The two Gigabit TP / SFP combo ports of all models can be either 1000Base-T for 10/100/1000Mbps or 1000Base-SX/LX through SFP (Small Factor Pluggable) interface. The distance can be extended from 100 meters (TP), 550 meters (Multi-mode fiber), up to above 10/50/70/120 kilometers (Single-mode fiber).

The GE-DS-82 series of Managed Switches boast a high performance switch architecture that is capable of providing non-blocking switch fabric and wire-speed throughput as high as 5.6Gbps. It’s two built-in GbE uplink ports also offer incredible extensibility, flexibility and connectivity to the Core switches or Servers.

Show 4 more labels / short text on this page
Installation Sheet x1 · Power cord x1 · Rubber feet X4 · RS-232 cable x1
Page 7 of the GE 82-POE user manual — Cost-effective solution with SNMP monitor for Network deployment
Page 7 · click to enlarge
Page 7
Chapter 1Introduction

Cost-effective solution with SNMP monitor for Network deployment

Not only catering to the needs of easy WEB-based management but also the centralized SNMP application to monitor the status of Switch and traffic per port, GE Security releases the cost-effective Managed Switch. The key features are listed below:

  • WEB / SSL / Telnet / Console management
  • 802.1Q / Q-in-Q VLAN
  • Rapid Spanning Tree
  • IGMP Snooping
  • 802.1X Authentication / RADIUS
  • Access Control List
  • SNMP and 4 RMON groups
  • 802.3af PoE (GE-DS-82-PoE)

Remote and Centralize Management installation

Afford the current network to grow and expand, the GE Security GE-DS-82 series provide advanced WEB and SNMP management interface to fill this kind of demand. With its built-in Web-based management, the GE-DS-82 series offers an easy-to-use, platform-independent management and configuration facility. It supports standard Simple Network Management Protocol (SNMP) and can be monitored via any standard-based management software.

For efficient management, via WEB interface the GE-DS-82 series can be programmed for basic switch management functions such as port speed configuration, Port Trunking, VLAN, Port Mirroring, Rapid Spanning Tree and Misc Configuration. Additionally, the firmware includes advanced features such as IGMP snooping, QoS (Quality of Service), broadcast storm and bandwidth control, to enhance bandwidth utilization.

The GE Security GE-DS-82 series offers comprehensive Access Control List (ACL) for enforcing security to the edge. Its protection mechanisms comprises of Port-based 802.1X user and device authentication. Moreover, the switch provides MAC filter and Static MAC for enforcing security policies to the edge. The administrators can now construct highly secured corporate networks with considerably less time and effort than before.

Powerful Security

Page 8 of the GE 82-POE user manual — GE-DS-82
Page 8 · click to enlarge
Page 8
Chapter 1Introduction

Power over Ethernet of GE-DS-82-PoE

The PoE in-line power following the standard IEEE 802.3af makes the GE-DS-82-PoE able to power 8 PoE devices at a distance of up to 100 meters through the 4-pair Cat 5/5e UTP wire.

How to Use this Manua l

This User Manual is structured as follows:

INTRODUCTION Product description with features and specifications

INSTALLATION Explains the functions of the Managed Switch, and how to physically install it

SWITCH MANAGEMENT Contains information about the software operation of the Managed Switch

WEB-BASED MANAGEMENT Explains how to manage the Managed Switch by Web interface

CONSOLE MANAGEMENT Describes how to use the Console Management Interface

COMMAND LINE INTERFACE

Explains how to manage the Managed Switch by Command Line Interface

SWITCH OPERATION Explains how to operate the Managed Switch

POWER OVER ETHERNET OVERVIEW

Introduces the IEEE 802.3af PoE standard and PoE provision of the Managed Switch.

TROUBLESHOOTING Explains how to troubleshoot the Managed Switch

APPENDIX A Contains cable information for the Managed Switch

Product Features

GE-DS-82

  • 8-Port 10/100Base-TX RJ-45 interfaces
  • 2 10/100/1000T TP combo interfaces
  • 2 mini-GBIC/SFP slots, shared with Port-9 and Port-10
  • Reset button for system management
  • 1 RS-232 male DB9 console interface for basic Switch management and setup

Section Section Content · Physical Port

Page 9 of the GE 82-POE user manual — Power over Ethernet of GE-DS-82-PoE
Page 9 · click to enlarge
Page 9
Chapter 1Introduction
  • 8-Port 10/100Base-TX RJ-45 with PoE Injector
  • 2 10/100/1000T TP combo interfaces
  • 2 mini-GBIC/SFP slots, shared with Port-9 and Port-10
  • Reset button for system management
  • 1 RS-232 male DB9 console interface for basic Switch management and setup
  • Prevents packet loss Flow Control:
  • IEEE 802.3x PAUSE frame Flow Control for Full-Duplex mode
  • Back-Pressure Flow Control in Half-Duplex mode
  • High performance Store and Forward architecture, broadcast storm control, runt/CRC filtering eliminates erroneous packets to optimize the network bandwidth
  • 8K MAC Address Table, automatic source address learning and ageing
  • Support VLAN :
  • IEEE 802.1Q Tag-Based VLAN
  • Port-Based VLAN
  • Q-in-Q tunneling (Double Tag VLAN)
  • GVRP for dynamic VLAN Management
  • Private VLAN Edge (PVE / Protect Port)
  • Supports Link Aggregation
  • Up to 13 Trunk groups
  • Up to 8 ports per trunk group with 1.6Gbps bandwidth (Full Duplex mode)
  • IEEE 802.3ad LACP (Link Aggregation Control Protocol)
  • Cisco ether-Channel (Static Trunk)
  • Support Spanning Tree Protocol:
  • STP, IEEE 802.1D (Classic Spanning Tree Protocol)
  • MSTP, IEEE 802.1s (Multiple Spanning Tree Protocol, spanning tree by VLAN)
  • 4 priority queues on all switch ports
  • Traffic classification:

GE-DS-82-PoE · Layer 2 Features · Quality of Service

Page 10 of the GE 82-POE user manual — Power over Ethernet of GE-DS-82-PoE
Page 10 · click to enlarge
Page 10
Chapter 1Introduction
  • IEEE 802.1p Class of Service
  • IP TOS / DSCP code priority
  • Port Base priority
  • Strict priority and weighted round robin (WRR) CoS policies
  • Ingress/Egress Bandwidth control on each port
  • IGMP Snooping v1 and v2
  • IGMP Snooping v2 fast leave
  • IGMP Query mode for Multicast Media application
  • IEEE 802.1x Port-Based network access control protocol
  • RADIUS users access authentication
  • L3 / L4 Access Control List (ACL)
  • Source IP-MAC / Port-Binding
  • Port Security for Source MAC address entries filtering
  • Switch Management Interface
  • Telnet Command Line Interface
  • Web switch management
  • SNMP v1, v2c, v3 switch management
  • SSL switch management
  • DHCP client for IP address assignment
  • DHCP Option82 and DHCP Relay
  • Link Layer Discovery Protocol (LLDP) for easy network management
  • Built-in Trivial File Transfer Protocol (TFTP) client
  • Firmware upgrade via TFTP or HTTP
  • Configuration restore / backup via TFTP or HTTP
  • Event message logging to remote Syslog server
  • Four RMON groups 1, 2, 3, 9 (history, statistics, alarms, and events)
  • SNMP trap for interface Link Up and Link Down notification
  • Supports Ping function

Multicast · Security · Management

Page 11 of the GE 82-POE user manual — Product Specifications
Page 11 · click to enlarge
Page 11
Chapter 1Introduction

Power over Ethernet (GE-DS-82-PoE Only)

  • Complies with IEEE 802.3af Power over Ethernet End-Span PSE
  • Up to 8 IEEE 802.3af devices can be powered
  • Supports PoE Power up to 15.4 Watts for each PoE port
  • Auto detect powered device (PD)
  • Circuit protection to prevent power interference between ports
  • Remote power feeding up to 100m
  • PoE Management
  • Total PoE power budget control
  • Per port PoE function enable/disable
  • PoE Port Power feeding priority
  • Per PoE port power limit
  • PD classification detection
  • PoE Power Supply Over Temperature Protection

Product Specifications

GE 82-POE — Product Specifications diagram (page 11)
Fig. 2 · Product Specifications
ProductGE-DS-82GE-DS-82-PoE Hardware Specification 10/100Mbps Copper Ports8 10/ 100Base-TX RJ-45 AutoMDI/MDI-X ports8 10/ 100Base-TX RJ-45 Auto-MDI/MDI-X ports 1000Mbps Copper Ports2 10/100/1000Base-T RJ-45 port SFP/mini-GBIC Slots2 SFP interfaces, shared with Port-9 and Port-10 Switch ArchitectureStore-and-Forward Switch Fabric5.6Gbps / non-blocking Switch Throughput4.16Mpps@64Bytes Address Table8K entries Share Data Buffer2Mbits Flash4Mbytess DRAM32Mbytes
Page 12 of the GE 82-POE user manual — Product Specifications
Page 12 · click to enlarge
Page 12
Chapter 1Introduction
GE 82-POE — Product Specifications diagram (page 12)
Fig. 3 · Product Specifications
Maximum Frame Size9K Bytes Flow ControlBack pressure for Half-Duplex IEEE 802.3x Pause Frame for Full-Duplex LEDPower Link/Activity (Green) 10/100 LNK / ACT (Green) 1000 LNK / ACT (Green) 10/100 LNK / ACT (Green)Power Link/Activity (Green) PoE In-Use (Amber) 1000 LNK / ACT (Green) 10/100 LNK / ACT (Green) Dimensions ( W x D x H)13” x 6.10” x 1.71” / 330 x 155 x 43.5mm 1U height13” x 6.10” x 1.71” / 330 x 155 x 43.5mm 330 1U height Weight2.8 lbs / 1.2kg3.49 lbs / 1.6kg Power Requirement100-240V AC, 50-60 Hz Power Consumption16 Watts (Full load)130 Watts (Full PoE Load) Operating TemperatureStandard: 0 - 50 Degree C Operating Humidity10% to 90% (Non-condensing) Storage Temperature-40 Degree C - 85 Degree C Layer 2 Functions Management InterfaceConsole, Telnet, Web Browser, SNMP v1, v2c and v3 Port ConfigurationPort disable/enable. Auto-negotiation 10/100Mbps full and half duplex mode selection. Flow Control disable / enable. Bandwidth control and broadcast storm filter on each port. Port StatusDisplay each port’s speed duplex mode, link status, Flow control status. Auto negotiation status VLANIEEE 802.1Q Tag-based VLAN, up to 255 VLANs groups, out of 4041 VLAN IDs Port-based VLAN Q-in-Q tunneling GVRP for VLAN Management, up to 128 dynamic VLAN entries Private VLAN Edge (PVE / Protected port) with two protected port groups Spanning TreeIEEE 802.1D Spanning Tree IEEE 802.1S Multiple Spanning Tree, up to 15 instances
Page 13 of the GE 82-POE user manual — Product Specifications
Page 13 · click to enlarge
Page 13
Chapter 1Introduction
GE 82-POE — Product Specifications diagram (page 13)
Fig. 4 · Product Specifications

Bandwidth Control Per port Ingress / Egress bandwidth control in steps of128Kbps

Access Control List Supports up to 220 rule entries

PoE Standard - IEEE 802.3af Power over Ethernet / PSE

PoE Power output - Per Port 48V DC, 350mA . Max. 15.4 watts

Page 14 of the GE 82-POE user manual — Product Specifications
Page 14 · click to enlarge
Page 14
Chapter 1Introduction
GE 82-POE — Product Specifications diagram (page 14)
Fig. 5 · Product Specifications
  • 50 / 125µm or 62.5 / 125µm multi-mode fiber cable:
  • 9 / 125µm single-mode cable, provides long distance for:
- 100Base-FXup to 10/40/60km (very on fiber transceiver or SFP module)

- 1000Base-LX / ZX: 10 / 15 / 20 / 30 / 40 / 50 / 60 / 70 / 120km (very on fiber transceiver or SFP module)

Page 15 of the GE 82-POE user manual — Switch Front Panel
Page 15 · click to enlarge
Page 15

Chapter 2 Installation

This section describes the hardware features and installation of the Managed Switch on the desktop or rack mount. For easier management and control of the Managed Switch, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Managed Switch, please read this chapter completely.

Hardware Description

Switch Front Panel

The unit front panel provides a simple interface for monitoring the Managed Switch. Figure 1 shows the front panels of the Managed Switches.

Figure 1GE-DS-82 and GE-DS-82-PoE Switch front panels
GE 82-POE — Switch Front Panel diagram (page 15)
Fig. 6 · Switch Front Panel

10/100Mbps TP Interface (GE-DS-82, GE-DS-82-PoE)

Port-1-Port-8: 10/100Base-TX Copper, RJ-45 Twist-Pair: Up to 100 meters.

Page 16 of the GE 82-POE user manual — LED Indications
Page 16 · click to enlarge
Page 16
Chapter 2Installation

Port-9, Port-10: 10/100/1000Base-T Copper, RJ-45 Twist-Pair: Up to 100 meters.

Port-9, Port-10: 1000Base-SX/LX mini-GBIC slot, SFP (Small Factor Pluggable) transceiver module: From 550 meters (Multi-mode fiber), up to 10/30/50/70/120 kilometers (Single-mode fiber).

At the left of front panel, the Reset button is designed to reboot the Managed Switch without turning the power off. The following table summarizes the Reset button functions:

Reset Button Pressed and Released Function

About 1-3 seconds Reboots the Managed Switch

Resets the Managed Switch to Factory Default configuration. The Managed Switch will then reboot and load the default settings as below:

  • Default Password: admin

Until the PWR LED goes out

  • Default IP address: 192.168.0.100
  • Subnet mask: 255.255.255.0
  • Default Gateway: 192.168.0.254

LED Indications

The front panel LEDs provide instant status of port links, data activity and system power. They help monitor the system and aid in troubleshooting when necessary. The front panel LEDs are shown in Figure 2.

Figure 2GE-DS-82 LED panel
GE 82-POE — LED Indications diagram (page 16)
Fig. 7 · LED Indications

Gigabit TP Interface · Gigabit SFP Slots · Reset button

Page 17 of the GE 82-POE user manual — LED Indications
Page 17 · click to enlarge
Page 17
Chapter 2Installation
  • System
PWR Green Litindicates there is power to the Switch
  • Per 10/100Base-T RJ-45 port
Litindicates the link through that port is successfully established
Blinkindicates the Switch is actively sending or receiving data over that port
  • Per 10/100/1000Base-T port/SFP interfaces
Litindicates the port is operating at 1000Mbps
Offindicates the port is operating at 10Mbps or 100Mbps
Blinkindicates the Switch is actively sending or receiving data over that port
Litindicates the port is operating at 100Mbps
Offindicates the port is operating at 10Mbps or 1000Mbps
Blinkindicates the Switch is actively sending or receiving data over that port
Figure 3GE-DS-82-PoE LED panel
GE 82-POE — LED Indications diagram (page 17)
Fig. 8 · LED Indications
  • System
PWR Green Litindicates there is power to the Switch
Show 7 more labels / short text on this page
LED Color Function · LED Color Function · LNK/ACT Green · LED Color Function · LNK/ACT 1000 Green · LNK/ACT 100 Green · LED Color Function
Page 18 of the GE 82-POE user manual — Switch Rear Panel
Page 18 · click to enlarge
Page 18
Chapter 2Installation
  • Per 10/100Base-TX, PoE interfaces (Port-1 to Port-8)
Litindicates the link through that port is successfully established
Blinkindicates the Switch is actively sending or receiving data over that port
Litindicates the port is providing 48VDC in-line power

PoE In Use Orange

Offindicates the connected device is not a PoE Powered Device (PD)
  • Per 10/100/1000Base-T port/SFP interfaces
Litindicates the port is operating at 1000Mbps
Offindicates the port is operating at 10Mbps or 100Mbps
Blinkindicates the Switch is actively sending or receiving data over that port
Litindicates the port is operating at 100Mbps
Offindicates the port is operating at 10Mbps or 1000Mbps
Blinkindicates the Switch is actively sending or receiving data over that port

NOTE:

1. Press the RESET button once. The Switch will reboot automatically.
2. Press the RESET button for about 10 seconds. The Switch will revert to the factory default mode; the entire configuration will be erased.
3. The 2 Gigabit TP/SFP combo ports are shared with port 9/10 of GE-DS-82 / GE-DS82-PoE. Both of them can operate at the same time.

Switch Rear Panel

The rear panel of the Managed Switch includes an AC inlet power socket, which accepts input power from 100 to 240VAC, 50-60 Hz. Figure 4 shows the rear panel of the Managed Switch.

Show 5 more labels / short text on this page
LED Color Function · LNK/ACT Green · LED Color Function · LNK/ACT 1000 Green · LNK/ACT 100 Green
Page 19 of the GE 82-POE user manual — POWER NOTICE:
Page 19 · click to enlarge
Page 19
Chapter 2Installation
Figure 4GE-DS-82 and GE-DS-82-PoE Rear panels
GE 82-POE — Switch Rear Panel diagram (page 19)
Fig. 9 · Switch Rear Panel

The console port is a DB9, RS-232 male serial port connector. It is an interface for connecting a terminal directly. The console port provides rich diagnostic information including IP Address setting, factory reset, port management, link status and system settings. Users can use the attached RS-232 cable in the package and connect to the console port on the device. After the connection, users can run any terminal emulation program (Hyper Terminal, ProComm Plus, Telix, Winterm and so on) to enter the startup screen of the device.

POWER NOTICE:

1. The Managed Switch is a power-required device: it will not work unless it is receiving power. If your networks must be active at all times, we recommend that the Switch be connected to a UPS (Uninterruptable Power Supply) to prevent data loss or downtime.
2. In some areas, installing a surge suppression device may also help protect your Managed Switch from being damaged by unregulated power surges or current to either the Switch or the power adapter.

Console Port

Page 20 of the GE 82-POE user manual — Desktop/Shelf Installation
Page 20 · click to enlarge
Page 20
Chapter 2Installation

Switch Installation

This section describes how to install the Managed Switch and connect it as necessary. Please read the following instructions, and perform the procedures in the listed order.

Desktop/Shelf Installation

1. Attach the rubber feet to the recessed areas on the bottom of the Managed Switch.
2. Place the Managed Switch on a desktop or shelf near an AC power source, as shown in Figure 5.
3. Ensure there is enough ventilation space between the Managed Switch and surrounding objects.
Figure 5Typical placement of GE-DS-82 on desktop
GE 82-POE — Desktop/Shelf Installation diagram (page 20)
Fig. 10 · Desktop/Shelf Installation
Page 21 of the GE 82-POE user manual — Rack-mount Installation
Page 21 · click to enlarge
Page 21
Chapter 2Installation
4. Connect the Managed Switch to network devices.

A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the Managed Switch.

B. Connect the other end of the cable to the network devices (printer servers, workstations, routers etc).

5. Supply power to the Managed Switch .

A. Connect socket end of the power cable to the socket on the Managed Switch rear panel.

B. Connect the power cable plug to a standard wall outlet.

C. Switch the power switch on the rear panel to ON. When the Managed Switch receives power, the Power LED should light and remain solid Green.

Rack-mount Installation

Use the following instructions to install the Managed Switch in a 19-inch standard rack.

1. Place the Managed Switch on a hard flat surface, with the front panel positioned towards the front.
2. Attach the rack-mount bracket to each side of the Managed Switch. Use the supplied screws attached to the package. Figure 6 shows how to attach brackets to one side of the Managed Switch.
Figure 6Attaching rack-mount brackets to the GE-DS-82
GE 82-POE — Rack-mount Installation diagram (page 21)
Fig. 11 · Rack-mount Installation
3. Secure the brackets tightly, but do not over tighten screws.
Page 22 of the GE 82-POE user manual — SFP Transceiver Installation
Page 22 · click to enlarge
Page 22
Chapter 2Installation
4. Follow the same steps to attach the second bracket to the opposite side.
5. After the brackets are attached to the Managed Switch, use suitable screws to securely attach the brackets to the rack, as shown in Figure 7.
Figure 7Mounting the GE-DS-82 in a rack
GE 82-POE — SFP Transceiver Installation diagram (page 22)
Fig. 12 · SFP Transceiver Installation
6. Follow steps 4 and 5 of the Desktop Installation section to connect the network cabling and supply power to the Managed Switch.

SFP Transceiver Installation

This section describes how to insert an SFP transceiver into an SFP slot.

SFP transceivers are hot pluggable and hot swappable. You can insert and remove a transceiver from any SFP port without powering down the Managed Switch, as shown in Figure 8.

Page 23 of the GE 82-POE user manual — SFP Transceiver Installation
Page 23 · click to enlarge
Page 23
Chapter 2Installation
Figure 8Plugging-in the SFP transceiver
GE 82-POE — SFP Transceiver Installation diagram (page 23)
Fig. 13 · SFP Transceiver Installation

Approved GE Security SFP Transceivers

The Managed Switch supports both single-mode and multi-mode SFP transceivers. The following list of approved GE Security SFP transceivers is correct at the time of publication:

1000Base-SX/LX SFP transceiver:

  • SFP1000SX-220 SFP (1000BASE-SX SFP transceiver - Multi mode / 220m)
  • SFP1000LX-10Km SFP (1000BASE-LX SFP transceiver - Single Mode / 10km)
Page 24 of the GE 82-POE user manual — SFP Transceiver Installation
Page 24 · click to enlarge
Page 24
Chapter 2Installation

Before connecting the other switches, workstations or Media Converter:

1. Make sure both sides of the SFP transceiver are the same media type (for example: 1000Base-SX to 1000Base-SX, 1000Base-LX to 1000Base-LX).
2. Verify that the fiber-optic cable type matches the SFP transceiver model.
  • To connect to a 1000Base-SX SFP transceiver, use multi-mode fiber cable (one side must be male duplex LC connector type).
  • To connect to a 1000Base-LX SFP transceiver, use single-mode fiber cable (one side must be male duplex LC connector type).

Connect the fiber cable:

1. Attach the duplex LC connector on the network cable into the SFP transceiver.
2. Connect the other end of the cable to a device (switches with SFP installed, fiber NIC on a workstation, or a Media Converter).
3. Check the LNK/ACT LED of the SFP slot on the front of the Switch. Ensure that the SFP transceiver is operating correctly.
4. Check the Link mode of the SFP port if the link failed. Co works with some fiber-NICs or Media Converters, set the Link mode to "1000 Force" is needed.

Remove the transceiver module

1. Make sure there is no network activity by consulting with the network administrator. You can also disable the port in advance by using the management interface.
2. Remove the Fiber Optic Cable gently.
3. Turn the handle of the MGB module to horizontal.
4. Pull out the module gently through the handle.
Page 25 of the GE 82-POE user manual — SFP Transceiver Installation
Page 25 · click to enlarge
Page 25
Chapter 2Installation
Figure 9Pulling out the SFP transceiver
GE 82-POE — SFP Transceiver Installation diagram (page 25)
Fig. 14 · SFP Transceiver Installation
Page 26 of the GE 82-POE user manual — SFP Transceiver Installation
Page 26 · click to enlarge
Page 26
Chapter 2Installation
Page 27 of the GE 82-POE user manual — Requirements
Page 27 · click to enlarge
Page 27

Chapter 3 Switch Management

This chapter explains the methods that you can use to configure management access to the Managed Switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (work-station or personal computer) and the system. It also contains information about port connection options.

This chapter covers the following topics:

  • Requirements
  • Management Access Overview
  • Administration Console Access
  • Web Management Access
  • SNMP Access
  • Standards, Protocols, and Related Reading.

Requirements

  • Clients of subscribers running Windows 98/ME, NT4.0, 2000/XP, MAC OS9 or later, Linux, UNIX or other platform compatible with TCP/IP protocols.
  • Workstation installed with Ethernet NIC (Network Interface Card)
  • Ethernet Port connect

o Network cables - Use standard network (UTP) cables with RJ45

connectors.

Summary

Page 28 of the GE 82-POE user manual — Management Access Overview
Page 28 · click to enlarge
Page 28
Chapter 3Switch Management
  • Above Workstation installed with WEB Browser and JAVA runtime environment Plug-in
  • Serial Port connect

o Above PC with COM Port (DB-9 / RS-232) or USB-to-RS-232 converter

Management Access Overview

The Managed Switch gives you the flexibility to access and manage it using any or all of the following methods:

  • Web browser interface
  • An external SNMP-based network management application
  • The Administration Console

The Administration Console and Web browser interface support are embedded in the Managed Switch software and are available for immediate use. Each of these management methods has their own advantages and disadvantages. Table 1 compares the three management methods.

Page 29 of the GE 82-POE user manual — Web Browser Management
Page 29 · click to enlarge
Page 29
Chapter 3Switch Management
Table 1Management Methods Comparison

Web Browser • Ideal for configuring the switch remotely

  • Security can be compromised (hackers need only know the IP address and subnet mask)
  • Compatible with all popular browsers
  • May encounter lag times on poor connections
  • Can be accessed from any location
  • Most visually appealing

SNMP Agent • Communicates with switch functions at the MIB level

  • Requires SNMP manager software
  • Least visually appealing of all three methods
  • Based on open standards
  • Some settings require calculations
  • Security can be compromised (hackers need only know the community name)

Console • No IP address or subnet needed

  • Must be near switch or use dial-up connection
  • Text-based
  • Not convenient for remote users
  • Telnet functionality and HyperTerminal built into Windows 95/98/NT/2000/ME/XP operating systems
  • Modem connection may prove to be unreliable or slow
  • Secure

Web Browser Management

The Managed Switch offers management features that allow users to manage the Managed Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer. After you set up your IP address for the switch, you can access the Managed Switch's Web interface applications directly in your Web browser by entering the IP address of the Managed Switch.

You can then use your Web browser to list and manage the Managed Switch configuration parameters from one central location, just as if you were directly connected to the Managed Switch's console port. Web Management requires either Microsoft Internet Explorer 6.0 or later, Safari or Mozilla Firefox 2.0 or later.

Method Advantages Disadvantages

Page 30 of the GE 82-POE user manual — Web Browser Setup
Page 30 · click to enlarge
Page 30
Chapter 3Switch Management

Web Browser Setup

The following shows how to start up the Web Management of the GE-DS-82 Managed Switch. Please note that the Managed Switch is configured through an Ethernet connection. Make sure the manager PC is set on the same IP subnet address.

For example, the default IP address of the GE-DS-82 Managed Switch is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.

Figure 10PC connected to Switch over Ethernet cable
GE 82-POE — Web Browser Setup diagram (page 30)
Fig. 15 · Web Browser Setup

Login to the managed Switch

1. Using Internet Explorer 6.0 enter the IP address http://192.168.0.100 (the factorydefault IP address or the IP address that you changed in the console) to access the Web interface.
2. When the following dialog box appears, please enter the default password "admin" (or the password you have changed via console). The login screen in Figure 11 appears.
  • Default Username: admin
  • Default Password: admin
Page 31 of the GE 82-POE user manual — Web Browser Setup
Page 31 · click to enlarge
Page 31
Chapter 3Switch Management
Figure 11Login screen
GE 82-POE — Web Browser Setup diagram (page 31)
Fig. 16 · Web Browser Setup
3. After entering the username and password, the main screen appears as shown in Figure 12.
Figure 12Web main screen of Managed Switch
GE 82-POE — Web Browser Setup diagram (page 31)
Fig. 17 · Web Browser Setup
Page 32 of the GE 82-POE user manual — The Administration Console
Page 32 · click to enlarge
Page 32
Chapter 3Switch Management

SNMP-Based Network Management

You can use an external SNMP-based application to configure and manage the Managed Switch, such as Snip Network Manager, HP Open view Network Node Management (NNM) or What’s up Gold. This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string. If the SNMP Net-work management Station only knows the set community string, it can read and write to the Mobs. However, if it only knows the get community string, it can only read Mobs. The default gets and sets community strings for the Managed Switch are public.

Figure 13SNMP Management
GE 82-POE — SNMP-Based Network Management diagram (page 32)
Fig. 18 · SNMP-Based Network Management

The Administration Console

The Administration Console is an internal, character-oriented, and command line user interface for performing system administration such as displaying statistics or changing option settings. Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch's console (serial) port.

There are two ways to use this management method: via direct access or modem port access. The following sections describe these methods. For more information about using the console, refer to Chapter 5: Console Management.

Page 33 of the GE 82-POE user manual — Direct Access
Page 33 · click to enlarge
Page 33
Chapter 3Switch Management
Figure 14PC connected to Switch with RS-232 serial cable

with Terminal emulation software

GE 82-POE — Direct Access diagram (page 33)
Fig. 19 · Direct Access
GE 82-POE — Direct Access diagram (page 33)
Fig. 20 · Direct Access
GE 82-POE — Direct Access diagram (page 33)
Fig. 21 · Direct Access

Serial Port 57600,8,n,1 RS-232

Direct Access

Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the Managed Switch console (serial) port.

When using this management method, a straight DB9 RS-232 cable is required to connect the switch to the PC. After making this connection, configure the terminal- emulation program to use the following parameters:

  • 57600 bps
  • 8 data bits
  • No parity
  • 1 stop bit
Figure 15Terminal parameter settings
GE 82-POE — Direct Access diagram (page 33)
Fig. 22 · Direct Access

PC / Workstation · Managed Switch · Serial Port

Page 34 of the GE 82-POE user manual — Telnet Setup
Page 34 · click to enlarge
Page 34
Chapter 3Switch Management

You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.

Protocols

The Managed Switch supports the following protocols:

  • Virtual terminal protocols, such as Telnet
  • Simple Network Management Protocol (SNMP)

Virtual Terminal Protocols

A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the Managed Switch before you can establish access to it with a virtual terminal protocol.

Terminal emulation differs from a virtual terminal protocol in that you must connect a terminal directly to the console (serial) port.

Telnet Setup

To access the Managed Switch through a Telnet session:

1. Connect an RJ-45 cable from the PC to a switch port on the Managed Switch.
2. Enable the Hyper Terminal program. A terminal program is required to make the software connection to the Managed Switch. Windows' Hyper Terminal program is a good choice. Hyper Terminal can be accessed from the Start menu. Click START , then Programs , Accessories and then Hyper Terminal .
3. The following screen will appear. Input a new connection name. You should use something like the model name of your switch.
Page 35 of the GE 82-POE user manual — Protocols
Page 35 · click to enlarge
Page 35
Chapter 3Switch Management
Figure 16New Connection dialog window
GE 82-POE — Protocols diagram (page 35)
Fig. 23 · Protocols
4. Change the Connect using drop-down menu to TCP/IP (Winsock) then input Host address. The Managed Switches default IP address is 192.168.0.100 and the default telnet port number is 23, then press the OK button.
Figure 17The Connect to dialog window
GE 82-POE — Protocols diagram (page 35)
Fig. 24 · Protocols

Log on to the Console

Make sure the device finished booting. Once the telnet has connected to the device, the hyper terminal will display the login request.

Then, the following message asks the login user name and password. The factory default password as following and the login screen as following appear.

User nameadmin
Passwordadmin
Page 36 of the GE 82-POE user manual — Management Architecture
Page 36 · click to enlarge
Page 36
Chapter 3Switch Management
Figure 18Login request window
GE 82-POE — SNMP Protocol diagram (page 36)
Fig. 25 · SNMP Protocol

Now you can configure the Switch by Telnet. The management interface is exactly the same with RS-232 console management.

SNMP Protocol

Simple Network Management Protocol (SNMP) is the standard management protocol for multi-vendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service.

Management Architecture

All of the management application modules use the same Messaging Application Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (console port, for example) are immediately displayable by the other management methods (for example, SNMP agent of Web browser).

The management architecture of the switch adheres to the IEEE open standard. This compliance assures customers that the Managed Switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.

Page 37 of the GE 82-POE user manual — Managed Switch
Page 37 · click to enlarge
Page 37

About Web-based Management

The Managed Switch offers management features that allow users to manage the Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer.

The Web-Based Manager supports Internet Explorer 6.0. It is based on Java Applets with an aim to reduce network bandwidth consumption, enhance access speed, and present an easy viewing screen.

The Managed Switch can be configured through an Ethernet connection, make sure the manager PC is set on same the IP subnet address with the Managed Switch.

Managed Switch

GE 82-POE — Managed Switch diagram (page 37)
Fig. 26 · Managed Switch

IP Address:

192.168.0.x

Page 38 of the GE 82-POE user manual — Requirements
Page 38 · click to enlarge
Page 38

For example, the default IP address of the Managed Switch is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.

If you have changed the default IP address of the Managed Switch to 192.168.1.1 with subnet mask 255.255.255.0 via console, then the manager PC should be set at 192.168.1.x (where x is a number between 2 and 254) to do the relative configuration on manager PC.

Requirements

  • Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS9 or later, Linux, UNIX or other platform compatible with TCP/IP protocols.
  • Workstation installed with Ethernet NIC (Network Card).
  • Ethernet Port connection

o Network cables - Use standard network (UTP) cables with RJ45

connectors.

o Above PC installed with a WEB Browser and a JAVA runtime

environment Plug-in.

Page 39 of the GE 82-POE user manual — Logging on to the Switch
Page 39 · click to enlarge
Page 39

Logging on to the Switch

1. Use Internet Explorer to enter the factory default IP address in the browser address field to access the Web interface. The factory-default IP Address is:

http://192.168.0.100

Figure 19Login screen
GE 82-POE — Logging on to the Switch diagram (page 39)
Fig. 27 · Logging on to the Switch
2. The login screen will appear. Enter the default username and password (or the username/password you have changed via console) to login to the main screen of Managed Switch.
User nameadmin
Passwordadmin
3. After entering the username and password, the main screen appears as shown in Figure 20.
Page 40 of the GE 82-POE user manual — Panel Display
Page 40 · click to enlarge
Page 40
Figure 20Main Web Page

The Menu on the left side of the Web page lets you access all the commands and statistics that the Switch provides.

Main Web Page

The Main web page allows you to configure the Managed Switch. This section describes how to use the Managed Switch's Web browser interface to configure and manage it.

Panel Display

Near the top of the web page the web agent displays an image of the Managed Switch's ports. The Mode can be set to display different information for the ports, including Link up or Link down. Clicking on the image of a port opens the Port Control page.

Page 41 of the GE 82-POE user manual — Main Menu
Page 41 · click to enlarge
Page 41
Figure 21Port Control page
GE 82-POE — Main Menu diagram (page 41)
Fig. 28 · Main Menu

The port states are illustrated as follows:

State Disabled Down Link

Main Menu

The Main menu is located on the left side of the Main Web Page. This is where all the configuration menus can be accessed.

RJ-45 Ports · SFP Ports · PoE Ports

Page 42 of the GE 82-POE user manual — System Information
Page 42 · click to enlarge
Page 42
Figure 22Main Menu
GE 82-POE — System diagram (page 42)
Fig. 29 · System

System

Use the System menu items to display and configure basic administrative details of the Managed Switch. Under System the following topics are provided to configure and view the system information: This section has the following items:

SYSTEM INFORMATION Provides basic system description, including contact information

IP CONFIGURATION Sets the IP address for management access

SNMP CONFIGURATION Configure SNMP agent and SNMP Trap

FIRMWARE UPGRADE Upgrade the firmware via TFTP server or Web Brower file transfer

Save/View the Managed Switch configuration to remote host.

CONFIGURATION BACKUP

Upload the switch configuration from remote host.

FACTORY DEFAULT Reset the configuration of the Managed Switch

SYSTEM REBOOT Restarts the Managed Switch

System Information

The System information menu contains 2 fields - Basic and Misc Config.

Page 43 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 43 · click to enlarge
Page 43

The Basic System Info page provides information for the current device information. Basic System Info page helps a switch administrator to identify the model name, firmware / hardware version and MAC address.

Figure 23Basic System Information screenshot
GE 82-POE — System diagram (page 43)
Fig. 30 · System

This page includes the following fields:

OBJECT DESCRIPTION

MODEL NAME Displays the system name of the Managed Switch

DESCRIPTION Describes the Managed Switch

MAC ADDRESS Displays the unique hardware address assigned by manufacturer (default)

FIRMWARE VERSION Displays the Managed Switch's firmware version

HARDWARE VERSION Displays the current hardware version

Select Misc Config from the System Information screen and the screen shown in Figure 24 appears.

Basic · Misc Config

Page 44 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 44 · click to enlarge
Page 44
Figure 24Switch Misc Config screenshot
GE 82-POE — System diagram (page 44)
Fig. 31 · System

This page includes the following fields:

OBJECT DESCRIPTION

Type the number of seconds that an inactive MAC address remains in the switch's address table. The value is a multiple of 6.

MAC Address Age-out Time

Default is 300 seconds.

To configure broadcast storm control, enable it and set the upper threshold for individual ports. The threshold is the percentage of the port's total bandwidth used by broadcast traffic. When broadcast traffic for a port rises above the threshold you set, broadcast storm control becomes active.

Broadcast Storm Filter Mode

The valid threshold values are 1/2, 1/4, 1/8, 1/16 and OFF.

Default is "OFF".

Page 45 of the GE 82-POE user manual — IP Configuration
Page 45 · click to enlarge
Page 45

To select broadcast storm Filter Packets type. If no packets types are selected, no filtering will occur. The Broadcast Storm Filter Mode will show OFF.

The selectable items as below:

Broadcast Storm Filter Packets Select

  • Broadcast Packets
  • IP Multicast
  • Control Packets
  • Flooded Unicast / Multicast Packets

Provide Collision Retry Forever function "Disable" or 16, 32, 48 collision numbers on Managed Switch. If this function is disabled, when a packet meet a collision, the Managed Switch will retry 6 times before discard the packets. Otherwise, the Managed Switch will retry until the packet is successfully sent.

Default value is 16.

Provide MAC address table Hashing setting on Managed Switch; available options are CRC Hash and Direct Map.

Default mode is CRC-Hash.

802.1x protocol Enable / disable 802.1x protocol

Apply button Press the button to complete the configuration.

IP Configuration

The Managed Switch is a network device, which needs to be assigned an IP address to be identified on the network. Users have to decide a means of assigning IP address to the Managed Switch.

What is an IP address?

Each device (such as a computer) which participates in an IP network needs a unique "address" on the network. It's similar to having a US mail address so other people have a know way to send you messages. An IP address is a four-byte number, which is usually written in "dot notation" - each of the bytes' decimal value is written as a number, and the numbers are separated by "dots" (aka periods). An example: 199.25.123.1

How do I get one for this box?

An employee called a “Network Administrator” assigns the IP addresses on most modern corporate nets. This person assigns IP addresses and is responsible for making sure that IP addresses are not duplicated - If this happens one or both machines with a duplicate address will stop working.

Another possibility is getting your address assigned to you automatically over the net via DHCP protocol. Enable DHCP function, and reset the machine. If your network is

Collision Retry Forever · Hash Algorithm

Page 46 of the GE 82-POE user manual — DHCP
Page 46 · click to enlarge
Page 46

set up for this service, you will get an IP address assigned over the network. If you don't get an address in about 30 seconds, you probably don't have DHCP.

The IP Configuration includes the IP Address, Subnet Mask and Gateway. The Configured column is used to view or change the IP configuration. Fill up the IP Address, Subnet Mask and Gateway for the device. The screen in Figure 25 appears.

Figure 25IP configuration interface
GE 82-POE — IP Configuration diagram (page 46)
Fig. 32 · IP Configuration

This page includes the following fields:

OBJECT DESCRIPTION

Enable or disable the DHCP client function.

When DHCP function is enabled, the Managed Switch will be assigned an IP address from the network DHCP server. The default IP address will be replaced by the assigned IP address on DHCP server. After the user clicks Apply, a popup dialog shows up to inform the user that when the DHCP client is enabled, the current IP will lose and user should find the new IP on the DHCP server.

DHCP

Assign the IP address that the network is using.

If DHCP client function is enabled, this switch is configured as a DHCP client. The network DHCP server will assign the IP address to the switch and display it in this column.

The default IP is 192.168.0.100 or the user has to assign an IP address manually when DHCP Client is disabled.

IP Configuration · IP Address

Page 47 of the GE 82-POE user manual — SNMP Configuration
Page 47 · click to enlarge
Page 47

Assign the subnet mask to the IP address.

If DHCP client function is disabled, the user has to assign the subnet mask in this column field.

Assign the network gateway for the switch.

If DHCP client function is disabled, the user has to assign the gateway in this column field.

The default gateway is 192.168.0.254.

SNMP Configuration

The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the Transmission Control Protocol/Internet Protocol (TCP/IP) protocol suite. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth.

Figure 26SNMP configuration interface
GE 82-POE — SNMP Configuration diagram (page 47)
Fig. 33 · SNMP Configuration

Subnet Mask · Gateway · SNMP Overview

Page 48 of the GE 82-POE user manual — SNMP Configuration
Page 48 · click to enlarge
Page 48

An SNMP-managed network consists of four key components: Network management stations (NMSs), SNMP agents, Management information base (MIB) and Network- management protocol:

  • Network management stations (NMSs): Sometimes called consoles, these devices execute management applications that monitor and control network elements. Physically, NMSs are usually engineering workstation-caliber computers with fast CPUs, megapixel color displays, substantial memory, and abundant disk space. At least one NMS must be present in each managed environment.
  • Agents: Agents are software modules that reside in network elements. They collect and store management information such as the number of error packets received by a network element.
  • Management information base (MIB): A MIB is a collection of managed objects residing in a virtual information store. Collections of related managed objects are defined in specific MIB modules.
  • Network-management protocol: A management protocol is used to convey management information between agents and NMSs. SNMP is the Internet community's de facto standard management protocol.

SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving a response.

  • Get - Allows the NMS to retrieve an object instance from the agent.
  • Set - Allows the NMS to set values for object instances within an agent.
  • Trap - Used by the agent to asynchronously inform the NMS of some event. The SNMPv2 trap message is designed to replace the SNMPv1 trap message.

An SNMP community is the group that devices and management stations running SNMP belong to. It helps define where information is sent. The community name is used to identify the group. A SNMP device or agent may belong to more than one SNMP community. It will not respond to requests from management stations that do not belong to one of its communities. SNMP default communities are:

  • Write = private
  • Read = public

Use this page to define management stations. You can also define a name, location, and contact person for the Managed Switch.

SNMP Overview · SNMP Community · System Options

Page 49 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 49 · click to enlarge
Page 49
Figure 27SNMP configuration interface
GE 82-POE — SNMP Configuration diagram (page 49)
Fig. 34 · SNMP Configuration

This page includes the following fields:

OBJECT DESCRIPTION

An administratively assigned name for this managed node. By convention, this is the node's fully qualified domain name. A domain name is a text string drawn from the alphabet (A-Za-z), digits (0-9), minus sign (-). No space characters are permitted as part of a name. The first character must be an alpha character. And the first or last character must not be a minus sign.

The allowed string length is 0 to 255.

The physical location of this node (e.g., telephone closet, 3rd floor).

The allowed string length is 0 to 255, and the allowed content is the ASCII characters from 32 to 126.

The textual identification of the contact person for this managed node, together with information on how to contact this person.

The allowed string length is 0 to 255, and the allowed content is the ASCII characters from 32 to 126.

Indicates the SNMP mode operation. Possible modes are:

  • Enabled: Enable SNMP mode operation.
  • Disabled: Disable SNMP mode operation.
Show 4 more labels / short text on this page
System Name · System Location · System Contact · SNMP Status
Page 50 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 50 · click to enlarge
Page 50

Community strings serve as passwords. See the table below.

Figure 28Community strings interface
GE 82-POE — SNMP Configuration diagram (page 50)
Fig. 35 · SNMP Configuration

This page includes the following fields:

OBJECT DESCRIPTION

Here you can define the new community string set and remove the unwanted community string.

  • String: Fill the name string.
  • RO: Read only. Enables requests accompanied by this community string to display MIB-object information.
  • RW: Read/write. Enables requests accompanied by this community string to display MIB-object information and to set MIB objects.

ADD button Press the button to add the management SNMP community strings on the Managed Switch.

REMOVE button Press the button to remove the management SNMP community strings that you defined before on the Managed Switch.

A trap manager is a management station that receives the trap messages generated by the switch. If no trap manager is defined, no traps will be issued. To define a management station as a trap manager, assign an IP address, enter the SNMP community strings, and select the SNMP trap version.

Figure 29Trap managers interface
GE 82-POE — OBJECT DESCRIPTION diagram (page 50)
Fig. 36

Community Strings · Community Strings · Trap Managers

Page 51 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 51 · click to enlarge
Page 51

This page includes the following fields:

OBJECT DESCRIPTION

85 Enter the IP address of the trap manager.

Community Enter the community string for the trap station.

Configure SNMPv3 groups table on this page. The entry index keys are Security Model and Security Name.

The SNMPv3 Groups Configuration screen in Figure 30 appears.

Figure 30SNMP Configuration Interface
GE 82-POE — OBJECT DESCRIPTION diagram (page 51)
Fig. 37

This page includes the following fields:

Group Name: A string identifying the group name that this entry should belong to.

The allowed string length is 1 to 15

V1 | V2c | USM Indicates the security model that this entry should belong to. Possible security models are:

v1: Reserved for SNMPv1.

v2c: Reserved for SNMPv2c.

usm: User-based Security Model (USM).

SNMPv3 Groups · Object Description

Page 52 of the GE 82-POE user manual — SNMPv3 View
Page 52 · click to enlarge
Page 52

Security Name: A string identifying the security name that this entry should belong to.

The allowed string length is 1 to 15

Remove Check to delete the entry. It will be deleted during the next save.

Configure the SNMPv3 views table on this page. The entry index keys are View Name and OID Subtree.

The SNMPv3 Views Configuration screen in Figure 31 appears.

Figure 31SNMP configuration interface
GE 82-POE — SNMPv3 View diagram (page 52)
Fig. 38 · SNMPv3 View

This page includes the following fields:

View Name: A string identifying the view name that this entry should belong to.

The allowed string length is 1 to 15

Included | ExcludedIndicates the view type that this entry should belong to. Possible view type are:

included: An optional flag to indicate that this view subtree should be included.

excluded: An optional flag to indicate that this view subtree should be excluded.

SNMPv3 View · Object Description

Page 53 of the GE 82-POE user manual — SNMPv3 View
Page 53 · click to enlarge
Page 53

View Subtree The OID defining the root of the subtree to add to the named view. The allowed OID length is 1 to 128. The allowed string content is digital number or asterisk(*)

View Mask (Hexadecimal Digits):

View mask is defined in order to reduce the amount of configuration information required when fine-grained access control is required (e.g., access control at

The object instance level)

Configure the SNMPv3 access table on this page. The entry index keys are Group Name, Security Model and Security Level.

The SNMPv3 Accesses Configuration screen in Figure 32 appears.

Figure 32SNMP configuration interface
GE 82-POE — SNMPv3 View diagram (page 53)
Fig. 39 · SNMPv3 View

This page includes the following fields:

A string identifying the group name that this entry should belong to.

Group Name:

The allowed string length is 1 to 15.

Indicates the security model that this entry should belong to. Possible security models are:

v1: Reserved for SNMPv1.

V1 | V2c | USM:

v2c: Reserved for SNMPv2c.

usmUser-based Security Model (USM)

SNMPv3 Access · Object Description

Page 54 of the GE 82-POE user manual — SNMPv3 View
Page 54 · click to enlarge
Page 54

Indicates the security model that this entry should belong to. Possible security models are:

SNMP Access:

NoAuth: None authentication and none privacy.

Auth: Authentication and none privacy.

Authpriv: Authentication and privacy.

The name of the MIB views defining the MIB objects for which this request may request the current values.

Read View:

The allowed string length is 1 to 16.

The name of the MIB views defining the MIB objects for which this request may potentially SET new values.

Write View:

The allowed string length is 1 to 16.

Notify View: Set up the notify view.

Remove Check to delete the selected entry. It will be deleted during the next save.

Configure SNMPv3 users table on this page. The entry index keys are Engine ID and User Name.

The SNMPv3 Users Configuration screen in Figure 33 appears.

Figure 33User configuration screen
GE 82-POE — SNMPv3 View diagram (page 54)
Fig. 40 · SNMPv3 View

SNMPv3 usm-user

Page 55 of the GE 82-POE user manual — Firmware Upgrade
Page 55 · click to enlarge
Page 55

This page include the following fields:

SNMP User Name: A string identifying the user name that this entry should belong to. The allowed string length is 1 to 15.

Indicates the authentication protocol that this entry should belong to. Possible authentication protocol are:

None: None authentication protocol.

Auth Type:

MD5: An optional flag to indicate that this user using MD5 authentication protocol.

The value of the security level cannot be modified if an entry already exists. That means must first ensure that the value is set correctly.

A string identifying the authentication pass phrase.

Auth Key (8-32):

For MD5 authentication protocol, the allowed string length is 8 to 32.

A string identifying the privacy pass phrase.

Private Key (8-32):

The allowed string length is 8 to 32.

Remove Check to delete the selected entry. It will be deleted during the next save.

Firmware Upgrade

It provides the functions allowing the user to update the switch firmware via the Trivial File Transfer Protocol (TFTP) server. Before updating, make sure the TFTP server is ready and the firmware image is located on the TFTP server.

The Firmware Upgrade page provides the functions to allow a user to update the Managed Switch firmware from the TFTP server in the network. Before updating, make sure you have your TFTP server ready and the firmware image is on the TFTP server. The screen in Figure 34 appears.

Use this menu to download a file from specified TFTP server to the Managed Switch.

Figure 34Firmware Upgrade interface
GE 82-POE — Firmware Upgrade diagram (page 55)
Fig. 41 · Firmware Upgrade

Object Description · TFTP Firmware Upgrade

Page 56 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 56 · click to enlarge
Page 56

This page includes the following fields:

OBJECT DESCRIPTION

TFTP Server IP Address Type in your TFTP server IP.

Firmware File Name Type in the name of the firmware image file to be updated.

The HTTP Firmware Upgrade page contains fields for downloading system image files from the Local File browser to the device. The Web Firmware Upgrade screen in Figure 35 appears.

Figure 35HTTP Firmware Upgrade interface
GE 82-POE — OBJECT DESCRIPTION diagram (page 56)
Fig. 42

To open the Firmware Upgrade screen, do the following:

1. Click System then Web Firmware Upgrade .
2. The Firmware Upgrade screen is displayed as in Figure 35.
3. Click the Browse button of the main page; the system will display the file selection menu to choose the firmware file. Click Open after the file is selected.
GE 82-POE — OBJECT DESCRIPTION diagram (page 56)
Fig. 43

HTTP Firmware Upgrade

Page 57 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 57 · click to enlarge
Page 57
4. Click Submit , the Software Upload Progress will show the file upload status.

Configuration Backup

You can restore a previous backup configuration from the TFTP server to recover the settings. Before doing that, you must locate the image file on the TFTP Server first and the Managed Switch will download the flash image.

Figure 36Configuration Restore interface
GE 82-POE — Configuration Backup diagram (page 57)
Fig. 44 · Configuration Backup

This page includes the following fields:

OBJECT DESCRIPTION

TFTP Server IP Address Type in your TFTP server IP.

Restore File Name Type in the correct file name for restoring.

TFTP Restore Configuration

Page 58 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 58 · click to enlarge
Page 58

You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later. It helps you to avoid wasting time on configuring the settings by backing up the configuration.

Figure 37Configuration Backup interface
GE 82-POE — Configuration Backup diagram (page 58)
Fig. 45 · Configuration Backup

This page includes the following fields:

OBJECT DESCRIPTION

TFTP Server IP Address Type in your TFTP server IP.

Backup File Name Type in the file name.

TFTP Backup Configuration

Page 59 of the GE 82-POE user manual — Factory Default
Page 59 · click to enlarge
Page 59

Factory Default

Reset switch to default configuration. Click reset to reset all configurations to the default value.

Figure 38Factory Default interface
GE 82-POE — Factory Default diagram (page 59)
Fig. 46 · Factory Default

Reboot the switch. Click reboot to reboot the system.

Figure 39System Reboot interface
GE 82-POE — Factory Default diagram (page 59)
Fig. 47 · Factory Default

System Reboot

Page 60 of the GE 82-POE user manual — Port Configuration
Page 60 · click to enlarge
Page 60

Syslog Setting

The Syslog Setting page allows you to configure the logging of messages that are sent to remote syslog servers or other management stations. You can also limit the event messages sent to only those messages below a specified level.

Figure 40Syslog setting web interface
GE 82-POE — Syslog Setting diagram (page 60)
Fig. 48 · Syslog Setting

This page includes the following settings:

OBJECT DESCRIPTION

Syslog Server IP IP address of syslog server.

Log level None: never send syslog message to syslog serverme, and Max Age parameters of the root bridge, regardless of how it is configured.

Majoronly send major syslog to syslog server, eg: link up/down, system warm/cold start

All: send all syslog message to syslog server.

Port Configuration

In Port control you can configure the settings of each port to control the connection parameters, and the status of each port is listed beneath.

Port Control

Page 61 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 61 · click to enlarge
Page 61
Figure 41Port Control interface
GE 82-POE — Syslog Setting diagram (page 61)
Fig. 49 · Syslog Setting

This page includes the following fields:

OBJECT DESCRIPTION

Port Use the scroll bar and click on the port number to choose the port to be configured.

State Current port state. The port can be set to disable or enable mode. If the port state is set as 'Disable', it will not receive or transmit any packet.

Auto and Force. Being set as Auto, the speed and duplex mode are negotiated automatically. When you set it as Force, you have to set the speed and duplex mode manually.

Speed It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set as Auto, this column is read-only.

Duplex It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set as Auto, this column is read-only.

Whether or not the receiving node sends feedback to the sending node is determined by this item. When enabled, once the device exceeds the input data rate of another device, the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time. When disabled, the receiving device will drop the packet if too much to process.

Negotiation · Flow Control

Page 62 of the GE 82-POE user manual — BSF
Page 62 · click to enlarge
Page 62

OBJECT DESCRIPTION

Port-1 - Port-24, supports by-port ingress and egress rate control.

For example, assume port 1 is 10Mbps, users can set its effective egress rate at 1Mbps and ingress rate at 500Kbps. Device will perform flow control or backpressure to confine the ingress rate to meet the specified rate.

  • Ingress: Type the port effective ingress rate.

The valid range is 0 - 8000. The unit is 128K.

(Unit128KBbps)
0. disable rate control.
1. 8000: valid rate value
  • Egress: Type the port effective egress rate.

The valid range is 0 - 8000. The unit is 128K.

0. disable rate control.

1 -8000: valid rate value.

A port in security mode will be "locked" without permission of address learning. Only the incoming packets with SMAC already existing in the address table can be forwarded normally.

User can disable the port from learning any new MAC addresses, then use the static MAC addresses screen to define a list of MAC addresses that can use the secure port. Enter the settings, then click Apply button to change on this page.

User can disable/Enable port broadcast storm filtering option by port.

BSF

The filter mode and filter packets type can be select in Switch Setting > Misc Config page.

Jumbo Frame User can disable/Enable port jumbo frame option by port. When port jumbo frame is enable, the port forward jumbo frame packet.

Rate Control · Security

Page 63 of the GE 82-POE user manual — Port Statistics
Page 63 · click to enlarge
Page 63

Port Status

This page displays current port configurations and operating status - it is a ports' configurations summary table. Via the summary table, you can find the status of each port clear at a glance, like Port Link Up/Link Down status, negotiation, Link Speed, Rate Control, Duplex mode and Flow Control.

Figure 42Port Status interface
GE 82-POE — Port Status diagram (page 63)
Fig. 50 · Port Status

Port Statistics

The following chart shows the current statistic information that displays the real-time packet transfer status for each port. The user might use the information to plan and implement the network, or check and find problems when collisions or heavy traffic occurs.

Page 64 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 64 · click to enlarge
Page 64
Figure 43Port Statistics interface
GE 82-POE — Port Status diagram (page 64)
Fig. 51 · Port Status

This page includes the following fields:

OBJECT DESCRIPTION

Port The port number.

Link The status of linking-'Up' or 'Down'

State Set by Port Control. When the state is disabled, the port will not transmit or receive any packet.

Tx Good Packet The counts of transmitting good packets via this port.

The counts of transmitting bad packets (including undersize [less than 64 octets], oversize, CRC Align errors, fragments and jabbers packets) via this port.

Rx Good Packet The counts of receiving good packets via this port.

Rx Bad Packet The counts of receiving good packets (including undersize [less than 64 octets], oversize, CRC error, fragments and jabbers) via this port.

Tx Abort Packet The aborted packet while transmitting.

Packet Collision The counts of collision packet.

Packet Dropped The counts of dropped packet.

Rx Bcast Packet The counts of broadcast packet.

Rx Mcast Packet The counts of multicast packet.

Tx Bad Packet

Page 65 of the GE 82-POE user manual — Port Sniffer
Page 65 · click to enlarge
Page 65

Port Sniffer

The Port Sniffer (mirroring) is a method for monitor traffic in switched networks. Traffic through a port can be monitored by one specific port. That is, traffic goes in or out a monitored port will be duplicated into the sniffer port.

Figure 44Port Mirror application
GE 82-POE — Port Sniffer diagram (page 65)
Fig. 52 · Port Sniffer

Configuring the port mirroring by assigning a source port from which to copy all packets and a destination port where those packets will be sent.

Page 66 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 66 · click to enlarge
Page 66
Figure 45Port Sniffer interface
GE 82-POE — Port Sniffer diagram (page 66)
Fig. 53 · Port Sniffer

This page includes the following fields:

OBJECT DESCRIPTION

Select a sniffer mode:

  • Disable
  • Rx
  • Tx
  • Both

It' means Analysis port can be used to see the traffic on another port you want to monitor. You can connect Analysis port to LAN analyzer or netxray.

The port you want to monitor. The monitor port traffic will be copied to the Analysis port. You can select one monitor per ports in the switch. User can choose which port that they want to monitor in only one sniffer type.

If you want to disable the function, you must select the monitor port to none.

Sniffer Type · Analysis (Monitoring) Port · Monitored Port

Page 67 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 67 · click to enlarge
Page 67

Protected Port

There are two protected port groups, ports in different groups can't communicate.

In the same group, protected ports can't communicate with each other, but can communicate with unprotected ports. Unprotected ports can communicate with any ports, including protected ports

Figure 46Protected Port setting web interface
GE 82-POE — Protected Port diagram (page 67)
Fig. 54 · Protected Port

This page includes the following fields:

OBJECT DESCRIPTION

Port ID Identify the Managed Switch interface.

Enable the Protected function on the selected port.

If the check box is not shown as

, then this port a unprotected port and it can communicate with any ports - including protected ports

Group 1 Set the protected port to be Group 1 member.

Group 2 Set the protected port to be Group 2 member.

Protected

Page 68 of the GE 82-POE user manual — NOTE:
Page 68 · click to enlarge
Page 68

VLAN Configuration

VLAN Overview

A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the physical layout. VLAN can be used to combine any collection of LAN segments into an autonomous user group that appears as a single LAN. VLAN also logically segment the network into different broadcast domains so that packets are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular subnet, although not necessarily.

VLAN can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific domains.

A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently communicate with each other are assigned to the same VLAN, regardless of where they are physically on the network. Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to only members of the VLAN on which the broadcast was initiated.

NOTE:

1. No matter what basis is used to uniquely identify end nodes and assign these nodes VLAN membership, packets cannot cross VLAN without a network device performing a routing function between the VLAN.
2. The Managed Switch supports IEEE 802.1Q VLAN. The port untagging function can be used to remove the 802.1 tag from packet headers to maintain compatibility with devices that are tag-unaware.

The Managed Switch supports IEEE 802.1Q (tagged-based) and Port-Base VLAN setting in web management page. In the default configuration, VLAN support is "802.1Q".

  • Port-based VLAN

Port-based VLAN limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or an entire department.

On port-based VLAN.NIC do not need to be able to identify 802.1Q tags in packet headers. NIC send and receive normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using normal Ethernet protocols. Even though this is always the case, when the destination for a packet lies

Page 69 of the GE 82-POE user manual — VLAN Configuration
Page 69 · click to enlarge
Page 69

on another switch port, VLAN considerations come into play to decide if the packet is dropped by the Switch or delivered.

  • IEEE 802.1Q VLANs

IEEE 802.1Q (tagged) VLAN are implemented on the Switch. 802.1Q VLAN require tagging, which enables them to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).

VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and this includes broadcast, multicast and unicast packets from unknown sources.

VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between stations that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally.

Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally.

Some relevant terms:

- Tagging - The act of putting 802.1Q VLAN information into the header of a packet.

- Untagging - The act of stripping 802.1Q VLAN information out of the packet header.

  • 802.1Q VLAN Tags

The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC address. Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field is equal to 0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used by 802.1p. The VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094 unique VLAN can be identified.

The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally contained in the packet is retained.

Page 70 of the GE 82-POE user manual — VLAN Configuration
Page 70 · click to enlarge
Page 70

802.1Q Tag

User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits

TPID (Tag Protocol Identifier) TCI (Tag Control Information)

2 bytes 2 bytes

Source Address VLAN TAG Ethernet

6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes

The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether Type/Length or Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC) must be recalculated.

Adding an IEEE802.1Q Tag

Dest. Addr. Src. Addr. Length/E. type Data Old CRC

Dest. Addr. Src. Addr. E. type Tag Length/E. type Data New CRC

Priority CFI VLAN ID

  • Port VLAN ID

Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant network device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices (and indeed, the entire network - if all network devices are 802.1Q compliant).

Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no VLAN are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this PVID, in so far as VLAN are concerned. Tagged packets are forwarded according to the VID contained within the tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the VID is.

Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID are different the switch will drop the packet. Because of the existence of the PVID for untagged packets and the VID

Show 5 more labels / short text on this page
Preamble Destination · Address · Type Data FCS · Original Ethernet · New Tagged Packet
Page 71 of the GE 82-POE user manual — Static VLAN Configuration
Page 71 · click to enlarge
Page 71

for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.

A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to store them.

Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware device before packets are transmitted - should the packet to be transmitted have a tag or not? If the transmitting port is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-aware device, the packet should be tagged.

  • Default VLANs

The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on the Switch to the "default". As new VLAN are configured in Port-based mode, their respective member ports are removed from the "default."

  • VLAN and Link Aggregation Groups

In order to use VLAN segmentation in conjunction with port link aggregation groups, you can first set the port link aggregation group(s), and then you may configure VLAN settings. If you wish to change the port link aggregation grouping with VLAN already in place, you will not need to reconfigure the VLAN settings after changing the port link aggregation group settings. VLAN settings will automatically change in conjunction with the change of the port link aggregation group settings.

Static VLAN Configuration

A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still plug into the same switch physically.

The Managed Switch supports Port-based and 802.1Q (Tagged-based) VLAN in the web management page. The default configuration, VLAN support is "802.1Q".

Page 72 of the GE 82-POE user manual — Port-Based VLAN
Page 72 · click to enlarge
Page 72
Figure 47Static VLAN interface
GE 82-POE — Port-Based VLAN diagram (page 72)
Fig. 55 · Port-Based VLAN

NOTE:

1. No matter what basis is used to uniquely identify end nodes and assign these nodes VLAN membership, packets cannot cross VLAN without a network device performing a routing function between the VLAN.
2. The Switch supports Port-based VLAN and IEEE 802.1Q VLAN . The port untagging function can be used to remove the 802.1 tag from packet headers to maintain compatibility with devices that are tag-unaware.

Port-Based VLAN

Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored.

In order for an end station to send packets to different VLANs, it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN-aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet, such as the protocol.

Page 73 of the GE 82-POE user manual — Port-Based VLAN
Page 73 · click to enlarge
Page 73
Figure 48Port-based VLAN interface
GE 82-POE — Port-Based VLAN diagram (page 73)
Fig. 56 · Port-Based VLAN

Create a VLAN and add member ports to it

1. Click the hyperlink "VLAN" \ "Static VLAN" to enter the VLAN configuration interface.
2. Select "Port Based VLAN" at the VLAN Operation Mode, to enable the portbased VLAN function.
3. Click "Add" to create a new VLAN group. Figure 49 appears.
4. Type a name and Group ID for the new VLAN, the available range is 2-4094 .
5. From the Available ports box, select ports to add to the Managed Switch and click Add .
6. Click Apply .
7. You will see the VLAN Group displays.
8. If the port-based VLAN groups list over one page, please click "Next Page" to view other VLAN groups on other page.
9. Use "Delete" button to delete unwanted port-based VLAN groups.
10. Use "Edit" button to modify existing port-based VLAN groups.

By adding ports to the VLAN you have created one port-based VLAN group completely.

Page 74 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 74 · click to enlarge
Page 74
Figure 49Static VLAN interface
GE 82-POE — Port-Based VLAN diagram (page 74)
Fig. 57 · Port-Based VLAN

This page includes the following fields:

OBJECT DESCRIPTION

VLAN Name Use this optional field to specify a name for the VLAN. It can be up to 16 alphanumeric characters long, including blanks.

You can configure the ID number of the VLAN by this item. This field is used to add VLANs one at a time. The VLAN group ID and available range is 2-4094.

Port Indicate port 1 to port 26.

Add Defines the interface as a Port-Based member of a VLAN. Member

Remove Forbidden ports are not included in the VLAN.

Group ID

Page 75 of the GE 82-POE user manual — 802.1Q VLAN
Page 75 · click to enlarge
Page 75

802.1Q VLAN

Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create a VLAN across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a "tag" into the Ethernet frames. Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.

You can create and delete Tag-based VLAN. There are 256 VLAN groups to provide configure. Enable 802.1Q VLAN, the all ports on the switch belong to default VLAN, VID is 1. The default VLAN can't be deleting.

Understand nomenclature of the Switch

  • IEEE 802.1Q Tagged and Untagged

Every port on an 802.1Q compliant switch can be configured as tagged or untagged.

Tagged Ports with tagging enabled will put the VID number, priority and other VLAN information into the header of all packets that flow into those ports. If a packet has previously been tagged, the port will not alter the packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by other 802.1Q compliant devices on the network to make packet-forwarding decisions.

Untagged Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into those ports. If the packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is only used internally within the Switch). Untagging is used to send packets from an 802.1Q-compliant network device to a non-compliant network device.

Income Frame is tagged Income Frame is untagged

Leave port is tagged Frame remains tagged Tag is inserted

Leave port is untagged Tag is removed Frame remain untagged

Frame Income · Frame Leave

Page 76 of the GE 82-POE user manual — 802.1Q VLAN
Page 76 · click to enlarge
Page 76
  • VLAN Group Configuration
Figure 50VLAN Group Configuration interface
GE 82-POE — 802.1Q VLAN diagram (page 76)
Fig. 58
1. Click the hyperlink "VLAN" \ "Static VLAN" to enter the VLAN configuration interface.
2. Select "802.1Q" at the VLAN Operation Mode, to enable the 802.1Q VLAN function.
3. Click Add to create a new VLAN group or Edit to management exist VLAN groups. Then the VLAN Group column appears.
4. Input a VLAN group ID and available range is 2-4094.

VLAN Group Configuration

Page 77 of the GE 82-POE user manual — 802.1Q VLAN
Page 77 · click to enlarge
Page 77
Figure 51VLAN Group Configuration interface
GE 82-POE — 802.1Q VLAN diagram (page 77)
Fig. 59
5. Select specific port as member port. Figure 52 appears.
6. After setup completed, please press "Apply" button to take effect.
7. Please press "Back" for return to VLAN configuration screen to add other VLAN group.
8. If there are many groups that over the limit of one page, you can click Next to view other VLAN groups.
9. Use Delete button to delete unwanted VLAN.
10. Use Edit button to modify existing VLAN group.
Page 78 of the GE 82-POE user manual — VLAN ID
Page 78 · click to enlarge
Page 78
Figure 52802.1Q VLAN Setting Web Page screen
GE 82-POE — 802.1Q VLAN diagram (page 78)
Fig. 60

This page includes the following fields:

OBJECT DESCRIPTION

VLAN Name Use this optional field to specify a name for the VLAN. It can be up to 16 alphanumeric characters long, including blanks.

You can configure the ID number of the VLAN by this item. This field is used to add VLANs one at a time.

VLAN ID

The VLAN group ID and available range is 2-4094.

Port Indicate port 1 to port 26.

Untag Packets forwarded by the interface are untagged.

Defines the interface as a tagged member of a VLAN. All packets forwarded by the interface are tagged. The packets contain VLAN information.

UnTag Member · Tag

Page 79 of the GE 82-POE user manual — PVID
Page 79 · click to enlarge
Page 79
  • 802.1Q VLAN Port Configuration

This page is used for configuring the Switch port VLAN. The VLAN per Port Configuration page contains fields for managing ports that are part of a VLAN. The port default VLAN ID (PVID) is configured on the VLAN Port Configuration page. All untagged packets arriving to the device are tagged by the ports PVID.

This section provides 802.1Q Ingress Filter of each port from the Switch, the screen in Figure 53 appears.

Figure 53802.1Q Ingress filter interface
GE 82-POE — 802.1Q VLAN diagram (page 79)
Fig. 61

This page includes the following fields:

OBJECT DESCRIPTION

NO Indicate port 1 to port 26.

Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for accommodating devices that you want to participate in the VLAN but that don't support tagging.

PVID

The switch each port allows user to set one VLAN ID, the range is 1-255, default VLAN ID is 1.

The VLAN ID must as same as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.

VLAN Filter

Page 80 of the GE 82-POE user manual — 802.1Q VLAN
Page 80 · click to enlarge
Page 80

OBJECT DESCRIPTION

Ingress filtering lets frames belonging to a specific VLAN to be forwarded if the port belongs to that VLAN.

Enable: Forward only packets with VID matching this port's configured VID.

Disable: Disable Ingress filter function.

Drop untagged frame.

Disable: Acceptable all Packet.

Enable: Only packet with match VLAN ID can be permission to go through the port.

Apply button Press the button to save configurations.

802.1Q VLAN

  • IEEE 802.1Q Tunneling (Q-in-Q)

IEEE 802.1Q Tunneling (QinQ) is designed for service providers carrying traffic for multiple customers across their networks. QinQ tunneling is used to maintain customer-specific VLAN and Layer 2 protocol configurations even when different customers use the same internal VLAN IDs. This is accomplished by inserting Service Provider VLAN (SPVLAN) tags into the customer's frames when they enter the service provider's network, and then stripping the tags when the frames leave the network.

A service provider's customers may have specific requirements for their internal VLAN IDs and number of VLANs supported. VLAN ranges required by different customers in the same service-provider network might easily overlap, and traffic passing through the infrastructure might be mixed. Assigning a unique range of VLAN IDs to each customer would restrict customer configurations, require intensive processing of VLAN mapping tables, and could easily exceed the maximum VLAN limit of 4096.

GE 82-POE — 802.1Q VLAN diagram (page 80)
Fig. 62

Ingress Filtering 1 · Ingress Filtering 2

Page 81 of the GE 82-POE user manual — 802.1Q VLAN
Page 81 · click to enlarge
Page 81

The Managed Switch supports multiple VLAN tags and can therefore be used in MAN applications as a provider bridge, aggregating traffic from numerous independent customer LANs into the MAN (Metro Access Network) space. One of the purposes of the provider bridge is to recognize and use VLAN tags so that the VLANs in the MAN space can be used independent of the customers' VLANs. This is accomplished by adding a VLAN tag with a MAN-related VID for frames entering the MAN. When leaving the MAN, the tag is stripped and the original VLAN tag with the customer- related VID is again available.

This provides a tunneling mechanism to connect remote costumer VLANs through a common MAN space without interfering with the VLAN tags. All tags use EtherType 0x8100 or 0x88A8, where 0x8100 is used for customer tags and 0x88A8 are used for service provider tags.

In cases where a given service VLAN only has two member ports on the switch, the learning can be disabled for the particular VLAN and can therefore rely on flooding as the forwarding mechanism between the two ports. This way, the MAC table requirements are reduced.

The QinQ VLAN \ QinQ Port Setting screen in Figure 54 appears.

Figure 54Q-in-Q Port Setting interface
GE 82-POE — 802.1Q VLAN diagram (page 81)
Fig. 63

Q-in-Q Port Setting

Page 82 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 82 · click to enlarge
Page 82

This page includes the following fields:

OBJECT DESCRIPTION

Enable Sets the Managed Switch to QinQ mode, and allows the QinQ tunnel port to be configured.

Disable The Managed Switch operates in its normal VLAN mode. QinQ

The default is for the Managed Switch to function in Disable mode.

The Tag Protocol Identifier (TPID) specifies the ethertype of incoming packets on a tunnel access port.

  • 802.1Q Tag : 8100
  • vMAN Tag : 88A8

Default : 802.1Q Tag.

Check: Sets the Port to QinQ mode. Or the port operates in its normal VLAN mode.

Default: Un-check.

Check Configures IEEE 802.1Q tunneling (QinQ) for an uplink port to another device within the service provider network. QinQ Uplink

Cancel Configures IEEE 802.1Q tunneling (QinQ) for a client access port to segregate and preserve customer VLAN IDs for traffic crossing the service provider network.

Business customers of service providers often have specific requirements for VLAN IDs and the number of VLANs to be supported. The VLAN ranges required by different customers in the same service-provider network might overlap, and traffic of customers through the infrastructure might be mixed. Assigning a unique range of VLAN IDs to each customer would restrict customer configurations and could easily exceed the VLAN limit (4096) of the IEEE 802.1Q specification.

Using the QinQ feature, service providers can use a single VLAN to support customers who have multiple VLANs. Customer VLAN IDs are preserved, and traffic from different customers is segregated within the service-provider network, even when they appear to be in the same VLAN. Using QinQ expands VLAN space by using a VLAN-in-VLAN hierarchy and retagging the tagged packets. A port configured to support QinQ is called a QinQ user-port. A port configured to support QinQ Uplink is called a QinQ uplink-port.

QinQ TPID · Port QinQ · Q-in-Q Tunnel Setting

Page 83 of the GE 82-POE user manual — 802.1Q VLAN
Page 83 · click to enlarge
Page 83
Figure 55Q-in-Q Tunnel Setting interface
  • To configure the QinQ Port do the following:
1. Enable global QinQ function: select QinQ enable "Enable" .
2. Fill QinQ Tpid.
3. Enable port QinQ function: select QinQ checkbox for special port.
4. Enable port QinQ Uplink function: select QinQ Uplink checkbox for special port.
Page 84 of the GE 82-POE user manual — GVRP Setting
Page 84 · click to enlarge
Page 84

GVRP VLAN

GVRP (GARP VLAN Registration Protocol or Generic VLAN Registration Protocol) is a protocol that facilitates control of virtual local area networks (VLANs) within a larger network. GVRP conforms to the IEEE 802.1Q specification, which defines a method of tagging frames with VLAN configuration data. This allows network devices to dynamically exchange VLAN configuration information with other devices.

GE 82-POE — GVRP VLAN diagram (page 84)
Fig. 64

GVRP Setting

Enable global GVRP function: select GVRP enable "Enable".

Enable port GVRP function: select GVRP checkbox for special port.

To configure GVRP

Page 85 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 85 · click to enlarge
Page 85
Figure 56GVRP Configuration web interface
GE 82-POE — GVRP VLAN diagram (page 85)
Fig. 65

This page includes the following fields:

OBJECT DESCRIPTION

GVRP Enable global GVRP function

Port Indicate port 1 to port 10.

Port GVRP Enable selected port GVRP function

Page 86 of the GE 82-POE user manual — VLAN ID
Page 86 · click to enlarge
Page 86

The GVRP Table can be used to display dynamic VLANs from being learned via GVRP.

Figure 57GVRPTable web interface
GE 82-POE — GVRP VLAN diagram (page 86)
Fig. 66

This page includes the following fields:

OBJECT DESCRIPTION

Display the learned VLANs via GVRP protocol on GVRP enabled ports.

VLAN ID

The Managed Switch allows displaying up to 128 dynamic VLAN entries.

Port Members Identify the GVRP enabled port that dynamic VLAN is learned from.

GVRP Table

Page 87 of the GE 82-POE user manual — Theory
Page 87 · click to enlarge
Page 87

Rapid Spanning Tree

The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and the system will auto-detect the connected device that is running STP or RSTP protocol.

Theory

The Spanning Tree protocol can be used to detect and disable network loops, and to provide backup links between switches, bridges or routers. This allows the switch to interact with other bridging devices in your network to ensure that only one route exists between any two stations on the network, and provide backup links which automatically take over when a primary link goes down. The spanning tree algorithms supported by this switch include these versions:

  • STP - Spanning Tree Protocol (IEEE 802.1D)
  • RSTP - Rapid Spanning Tree Protocol (IEEE 802.1w)

The IEEE 802.1D Spanning Tree Protocol and IEEE 802.1W Rapid Spanning Tree Protocol allow for the blocking of links between switches that form loops within the network. When multiple links between switches are detected, a primary link is established. Duplicated links are blocked from use and become standby links. The protocol allows for the duplicate links to be used in the event of a failure of the primary link. Once the Spanning Tree Protocol is configured and enabled, primary links are established and duplicated links are blocked automatically. The reactivation of the blocked links (at the time of a primary link failure) is also accomplished automatically without operator intervention.

This automatic network reconfiguration provides maximum uptime to network users. However, the concepts of the Spanning Tree Algorithm and protocol are a complicated and complex subject and must be fully researched and understood. It is possible to cause serious degradation of the performance of the network if the Spanning Tree is incorrectly configured. Please read the following before making any changes from the default values.

The Switch STP performs the following functions:

  • Creates a single spanning tree from any combination of switching or bridging elements.
  • Creates multiple spanning trees - from any combination of ports contained within a single switch, in user specified groups.
Page 88 of the GE 82-POE user manual — Rapid Spanning Tree
Page 88 · click to enlarge
Page 88
  • Automatically reconfigures the spanning tree to compensate for the failure, addition, or removal of any element in the tree.
  • Reconfigures the spanning tree without operator intervention.

Bridge Protocol Data Units

For STP to arrive at a stable network topology, the following information is used:

  • The unique switch identifier
  • The path cost to the root associated with each switch port
  • The port identifier

STP communicates between switches on the network using Bridge Protocol Data Units (BPDUs). Each BPDU contains the following information:

  • The unique identifier of the switch that the transmitting switch currently believes is the root switch.
  • The path cost to the root from the transmitting port.
  • The port identifier of the transmitting port.

The switch sends BPDUs to communicate and construct the spanning-tree topology. All switches connected to the LAN on which the packet is transmitted will receive the BPDU. BPDUs are not directly forwarded by the switch, but the receiving switch uses the information in the frame to calculate a BPDU, and, if the topology changes, initiates a BPDU transmission.

The communication between switches via BPDUs results in the following:

  • One switch is elected as the root switch.
  • The shortest distance to the root switch is calculated for each switch.
  • A designated switch is selected. This is the switch closest to the root switch through which packets will be forwarded to the root.
  • A port for each switch is selected. This is the port providing the best path from the switch to the root switch.
  • Ports included in the STP are selected.

Creating a Stable STP Topology

To make the root port the fastest link. If all switches have STP enabled with default settings, the switch with the lowest MAC address in the network will become the root switch. By increasing the priority (lowering the priority number) of the best switch, STP can be forced to select the best switch as the root switch.

Page 89 of the GE 82-POE user manual — Rapid Spanning Tree
Page 89 · click to enlarge
Page 89

When STP is enabled using the default parameters, the path between source and destination stations in a switched network might not be ideal. For instance, connecting higher-speed links to a port that has a higher number than the current root port can cause a root-port change.

The BPDUs take some time to pass through a network. This propagation delay can result in topology changes where a port that transitioned directly from a Blocking state to a Forwarding state could create temporary data loops. Ports must wait for new network topology information to propagate throughout the network before starting to forward packets. They must also wait for the packet lifetime to expire for BPDU packets that were forwarded based on the old topology. The forward delay timer is used to allow the network topology to stabilize after a topology change. In addition, STP specifies a series of states a port must transition through to further ensure that a stable network topology is created after a topology change.

Each port on a switch using STP exists is in one of the following five states:

  • Blocking - the port is blocked from forwarding or receiving packets.
  • Listening - the port is waiting to receive BPDU packets that may tell the port to go back to the blocking state.
  • Learning - the port is adding addresses to its forwarding database, but not yet forwarding packets.
  • Forwarding - the port is forwarding packets.
  • Disabled - the port only responds to network management messages and must return to the blocking state first.

A port transitions from one state to another as follows:

  • From initialization (switch boot) to blocking.
  • From blocking to listening or to disabled.
  • From listening to learning or to disabled.
  • From learning to forwarding or to disabled.
  • From forwarding to disabled.
  • From disabled to blocking.

STP Port States

Page 90 of the GE 82-POE user manual — Illustration of STP
Page 90 · click to enlarge
Page 90
Figure 58STP Port State Transitions
GE 82-POE — Illustration of STP diagram (page 90)
Fig. 67 · Illustration of STP

You can modify each port state by using management software. When you enable STP, every port on every switch in the network goes through the blocking state and then transitions through the states of listening and learning at power up. If properly configured, each port stabilizes to the forwarding or blocking state. No packets (except BPDUs) are forwarded from, or received by, STP enabled ports until the forwarding state is enabled for that port.

Illustration of STP

A simple illustration of three switches connected in a loop is depicted in the following figure. In this example, you can anticipate some major network problems if the STP assistance is not applied.

If switch A broadcasts a packet to switch B, switch B will broadcast it to switch C, and switch C will broadcast it to back to switch A and so on. The broadcast packet will be passed indefinitely in a loop, potentially causing a network failure. In this example, STP breaks the loop by blocking the connection between switch B and C. The decision to block a particular connection is based on the STP calculation of the most current Bridge and Port settings.

Now, if switch A broadcasts a packet to switch C, then switch C will drop the packet at port 2 and the broadcast will end there. Setting-up STP using values other than the defaults, can be complex. Therefore, you are advised to keep the default factory settings and STP will automatically assign root bridges/ports and block loop connections. Influencing STP to choose a particular switch as the root bridge using

Page 91 of the GE 82-POE user manual — Illustration of STP
Page 91 · click to enlarge
Page 91

the Priority setting, or influencing STP to choose a particular port to block using the Port Priority and Port Cost settings is, however, relatively straight forward.

Figure 59Before Applying the STA Rules
GE 82-POE — Illustration of STP diagram (page 91)
Fig. 68 · Illustration of STP

In this example, only the default STP values are used.

Figure 60After Applying the STA Rules
GE 82-POE — Illustration of STP diagram (page 91)
Fig. 69 · Illustration of STP
Page 92 of the GE 82-POE user manual — 32768 + MAC
Page 92 · click to enlarge
Page 92

The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 4) on switch A are connected to one (optional) Gigabit port on both switch B and C. The redundant link between switch B and C is deliberately chosen as a 100 Mbps Fast Ethernet link (default port cost = 19). Gigabit ports could be used, but the port cost should be increased from the default to ensure that the link between switch B and switch C is the blocked link.

STP Parameters

The Switch allows for two levels of operation: the switch level and the port level. The switch level forms a spanning tree consisting of links between one or more switches. The port level constructs a spanning tree consisting of groups of one or more ports. The STP operates in much the same way for both levels.

On the port level, STP sets the Root Port and the Designated Ports.

The following are the user-configurable STP parameters for the switch level:

PARAMETER DESCRIPTION DEFAULT VALUE

A combination of the User-set priority and the switch's MAC address.

Bridge Identifier (Not user configurable except by setting priority below)

The Bridge Identifier consists of two parts:

32768 + MAC

a 16-bit priority and a 48-bit Ethernet MAC address 32768 + MAC.

A relative priority for each switch - lower numbers give a higher priority and a greater chance of a given switch being elected as the root bridge.

Hello Time The length of time between broadcasts of the hello message by the switch. 2 seconds

Measures the age of a received BPDU for a port and ensures that the BPDU is discarded when its age exceeds the value of the maximum age timer.

The amount time spent by a port in the learning and listening states waiting for a BPDU that may return the port to the blocking state.

Show 6 more labels / short text on this page
STP Operation Levels · Priority · Maximum Age Timer · 20 seconds · Forward Delay Timer · 15 seconds
Page 93 of the GE 82-POE user manual — RSTP System Configuration
Page 93 · click to enlarge
Page 93

The following are the user-configurable STP parameters for the port or port group level:

PARAMETER DESCRIPTION DEFAULT VALUE

A relative priority for each switch - lower numbers give a higher priority and a greater chance of a given switch being elected as the root bridge.

200,000-100Mbps Fast Ethernet ports

A value used by STP to evaluate paths - STP calculates path costs and selects the path with the minimum cost as the active path.

20,000-1000Mbps Gigabit Ethernet ports

0. Auto

Enable state STP disabled for all ports

Observe the following formulas when setting the above parameters:

  • Max. Age _ 2 x (Forward Delay - 1 second)
  • Max. Age _ 2 x (Hello Time + 1 second)

RSTP System Configuration

This section provides RSTP-System Configuration from the Switch, the screen in Figure 61 appears.

  • The user can view spanning tree information of Root Bridge.
  • The user can modify RSTP state. After modification, click the Apply button.
Show 7 more labels / short text on this page
Port Priority · Port Cost · Default Spanning-Tree Configuration · Feature Default Value · Port priority 128 · Port cost 0 · Bridge Priority 32,768
Page 94 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 94 · click to enlarge
Page 94
Figure 61RSTP System Configuration interface
GE 82-POE — RSTP System Configuration diagram (page 94)
Fig. 70 · RSTP System Configuration

This page includes the following fields:

OBJECT DESCRIPTION

RSTP mode The user must enable the RSTP function first before configuring the related parameters.

A value used to specify the spanning tree protocol, the original spanning tree protocol (STP, 802.1d) or the rapid spanning tree protocol (RSTP, 802.1w).

The switch with the lowest value has the highest priority and is selected as the root. If the value is changed, the user must reboot the switch.

The value must be a multiple of 4096 according to the protocol standard rule.

The number of seconds a switch waits without receiving Spanning-tree Protocol configuration messages before attempting a reconfiguration.

Enter a value between 6 through 40.

The time that controls the switch to send out the BPDU packet to check RSTP current status.

Enter a value between 1 through 10.

The number of seconds a port waits before changing from its Rapid Spanning-Tree Protocol learning and listening states to the forwarding state.

Forward Delay Time (4-30)

Enter a value between 4 through 30.

Show 4 more labels / short text on this page
Protocol Version · Priority (0-61440) · Max Age (6-40) · Hello Time (1-10)
Page 95 of the GE 82-POE user manual — RSTP System Configuration
Page 95 · click to enlarge
Page 95

2 x (Forward Delay Time value -1) > = Max Age value >= 2 x (Hello Time value +1).

This page provides a status overview for all RSTP bridge instances.

The displayed table contains a row for each RSTP bridge instance, where the column displays the following information:

The RSTP Bridge Status screen in Figure 62 appears.

Figure 62RSTP Bridge Status page screenshot
GE 82-POE — RSTP System Configuration diagram (page 95)
Fig. 71 · RSTP System Configuration

Root Bridge Information

Page 96 of the GE 82-POE user manual — Port Configuration
Page 96 · click to enlarge
Page 96

This page includes the following fields:

OBJECT DESCRIPTION

Priority The bridge identifier of the root bridge. It is made up from the bridge priority and the base MAC address of the bridge.

MAC Address The bridge identifier of the root bridge. It is made up from the bridge priority and the base MAC address of the bridge.

Root Path Cost For the Root Bridge this is zero. For all other Bridges, it is the sum of the Port Path Costs on the least cost path to the Root Bridge.

Root Port The switch port currently assigned the root port role.

Maximum Age Path Cost to the Designated Root for the Root Bridge.

Hello Time Minimum time between transmissions of Configuration BPDUs.

Forward Delay Derived value of the Root Port Bridge Forward Delay parameter.

Port Configuration

This web page provides the port configuration interface for RSTP. You can assign higher or lower priority to each port. Rapid spanning tree will have the port with the higher priority in forwarding state and block other ports to make certain that there is no loop in the LAN.

Figure 63RSTP Port Configuration interface
GE 82-POE — Port Configuration diagram (page 96)
Fig. 72 · Port Configuration
Page 97 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 97 · click to enlarge
Page 97

This page includes the following fields:

OBJECT DESCRIPTION

The cost of the path to the other bridge from this transmitting bridge at the specified port.

Enter a number 1 through 200,000,000.

Decide which port should be blocked by setting its priority as the lowest. Enter a number between 0 and 240.

The value of priority must be the multiple of 16.

The rapid state transitions possible within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge (i.e. it is served by a point-to-point LAN segment), or can be connected to two or more bridges (i.e. it is served by a shared medium LAN segment). This function allows the P2P status of the link to be manipulated administratively.

  • YES means the port is regarded as a point-to-point link.
  • NO means the port is regarded as a shared link.
  • AUTO means the link type is determined by the auto-negotiation between the two peers..

The port directly connected to end stations won't create bridging loop in the network. To configure the port as an edge port, set the port to "YES" status.

The port includes the STP mathematic calculation.

  • YES is not including STP mathematic calculation.
  • NO is including the STP mathematic calculation.

By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost according to the values shown below.

Show 5 more labels / short text on this page
Path Cost · Priority · Admin P2P · Admin Edge · Admin Non STP
Page 98 of the GE 82-POE user manual — Trunking
Page 98 · click to enlarge
Page 98

Recommended STP Path Cost Range

Port Type IEEE 802.1D-1998 IEEE 802.1w-2001

Fast Ethernet 10-60 20,000-2,000,000

Gigabit Ethernet 3-10 2,000-200,000

Recommended STP Path Cost Range

Port Type Link Type IEEE 802.1D-1998 IEEE 802.1w-2001

Fast Ethernet Half Duplex

Gigabit Ethernet Full Duplex

Trunking

Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable. The Managed Switch supports two types of port trunk technology:

  • Static Trunk
  • LACP

The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs, move the link to that Link Aggregation Group, and enable its transmission and reception functions in an orderly manner. Link aggregation lets you group up to eight consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the network. LACP operation requires full-duplex mode, more detail information refers to IEEE 802.3ad.

Show 16 more labels / short text on this page
Ethernet 50-600 200,000-20,000,000 · Ethernet · Half Duplex · 2,000,000 · Full Duplex · 1,999,999 · Trunk · 1,000,000 · 200,000 · Full Duplex · 100,000 · Trunk · 50,000 · 10,000 · Trunk · 5,000
Page 99 of the GE 82-POE user manual — Aggregator Setting
Page 99 · click to enlarge
Page 99
GE 82-POE — Aggregator Setting diagram (page 99)
Fig. 73 · Aggregator Setting

Aggregator Setting

This section provides Port Trunk-Aggregator Setting of each port from the Managed Switch, the screen in Figure 64 appears.

Figure 64: Port Trunk-Aggregator setting interface (two ports are added to the left field with LACP enabled)

GE 82-POE — Aggregator Setting diagram (page 99)
Fig. 74 · Aggregator Setting
Page 100 of the GE 82-POE user manual — Aggregator Information
Page 100 · click to enlarge
Page 100

This page includes the following fields:

OBJECT DESCRIPTION

A value, which is used to identify the active LACP. The Managed Switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group.

Group ID There are 13 trunk groups to be selected. Assign the "Group ID" to the trunk group.

  • Enabled , the trunk group is using LACP . A port which joins an LACP trunk group has to make an agreement with its member ports first.
  • Disabled , the trunk group is a static trunk group . The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports; but member ports won't know that they should be aggregated together to form a logic trunk group.

LACP

This column field allows the user to type in the total number of active port up to four. With LACP static trunk group, e.g. you assign four ports to be the members of a trunk group whose work ports column field is set as two; the exceed ports are standby/redundant ports and can be aggregated if working ports fail. If it is a static trunk group (non-LACP), the number of work ports must equal the total number of group member ports.

Aggregator Information

When you had setup the LACP aggregator, you will see relation information in here.

  • LACP disabled

Having set up the aggregator setting with LACP disabled, you will see the local static trunk group information on the tab of Aggregator Information.

System Priority · Work ports

Page 101 of the GE 82-POE user manual — Aggregator Information
Page 101 · click to enlarge
Page 101
Figure 65Assigning 2 ports to a trunk group with LACP disabled
GE 82-POE — Aggregator Information diagram (page 101)
Fig. 75 · Aggregator Information
Figure 66Static Trunking Group information
GE 82-POE — Aggregator Information diagram (page 101)
Fig. 76 · Aggregator Information
Page 102 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 102 · click to enlarge
Page 102

This page includes the following fields:

OBJECT DESCRIPTION

Group Key This is a read-only column field that displays the trunk group ID.

Port member This is a read-only column field that displays the members of this static trunk group.

Having set up the aggregator setting with LACP enabled, you will see the trunking group information between two switches on the tab of Aggregator Information.

  • Switch 1 configuration
1. Set System Priority of the trunk group. The default is 1.
2. Select a trunk group ID by pull down the drop-down menu bar.
3. Enable LACP .
4. Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically.
Figure 67Aggregation Information of Switch 1
5. Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured.

LACP enabled

Page 103 of the GE 82-POE user manual — Aggregator Information
Page 103 · click to enlarge
Page 103
  • Switch 2 configuration
6. Set System Priority of the trunk group. For example: 32768.
7. Select a trunk group ID by pull down the drop-down menu bar.
8. Enable LACP.
9. Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically.
Figure 68Switch 2 configuration interface
10. Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches are configured.
Page 104 of the GE 82-POE user manual — State Activity
Page 104 · click to enlarge
Page 104
Figure 69Switch 1 Aggregator Information
GE 82-POE — State Activity diagram (page 104)
Fig. 77 · State Activity

State Activity

Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure the state activity for the members of the LACP trunk group. You can tick or cancel the checkbox beside the state label. When you remove the tick mark of the port and click Apply, the port state activity will change to Passive.

Figure 70State Activity of Switch 1
GE 82-POE — State Activity diagram (page 104)
Fig. 78 · State Activity
Page 105 of the GE 82-POE user manual — Dynamic MAC Table
Page 105 · click to enlarge
Page 105

This page includes the following fields:

OBJECT DESCRIPTION

Active The port automatically sends LACP protocol packets.

The port does not automatically send LACP protocol packets, and responds only if it receives LACP protocol packets from the opposite device.

Forwarding and Filtering

The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MAC address of the equipment sending the frame. The SMAC address is used by the switch to automatically update the MAC table with these dynamic MAC addresses. Dynamic entries are removed from the MAC table if no frames with the corresponding SMAC address have been seen after a configurable age time.

Dynamic MAC Table

Entries in the MAC Table are shown on this page. The Dynamic MAC Table contains up to 8192 entries, and is sorted first by VLAN ID, then by MAC address. You can view all of the dynamic MAC addresses learned by the listed port.

Passive

Page 106 of the GE 82-POE user manual — Static MAC Table
Page 106 · click to enlarge
Page 106
Figure 71Dynamic MAC Address interface
GE 82-POE — Static MAC Table diagram (page 106)
Fig. 79 · Static MAC Table

OBJECT DESCRIPTION

NO The index of the MAC address entry.

MAC The MAC address of the entry.

PORT The ports that are members of the entry.

VID The VLAN ID of the entry.

Type Indicates whether the entry is a static or dynamic entry.

Click "Clear" to clear the dynamic MAC addresses information of the current port shown on the screen.

Static MAC Table

You can add a static MAC address that remains in the switch's address table regardless of whether the device is physically connected to the switch. This saves the switch from having to re-learn a device's MAC address when the disconnected or powered-off device is active on the network again. Via this interface, you can add / modify / delete a static MAC address.

Add the Static MAC Address

You can add static MAC address in the switch MAC table here.

MAC Table Entries

Page 107 of the GE 82-POE user manual — MAC Filtering
Page 107 · click to enlarge
Page 107
Figure 72Static MAC Addresses interface
GE 82-POE — MAC Filtering diagram (page 107)
Fig. 80 · MAC Filtering

This page includes the following fields:

OBJECT DESCRIPTION

MAC Address Enter the MAC address of the port that should permanently forward traffic, regardless of the device network activity.

Port Num Pull down the selection menu to select the port number.

VLAN ID The VLAN ID for the entry.

MAC Filtering

By filtering MAC address, the switch can easily filter the pre-configured MAC address and become more secure. You can add and delete filtering MAC address.

Page 108 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 108 · click to enlarge
Page 108
Figure 73MAC Filtering interface
GE 82-POE — MAC Filtering diagram (page 108)
Fig. 81 · MAC Filtering

This page includes the following fields:

OBJECT DESCRIPTION

MAC Address Enter the MAC address that you want to filter.

VLAN ID The VLAN ID for the entry.

Page 109 of the GE 82-POE user manual — Theory
Page 109 · click to enlarge
Page 109

IGMP Snooping

Theory

The Internet Group Management Protocol (IGMP) lets host and routers share information about multicast groups memberships. IGMP snooping is a switch feature that monitors the exchange of IGMP messages and copies them to the CPU for feature processing. The overall purpose of IGMP Snooping is to limit the forwarding of multicast frames to only ports that are a member of the multicast group.

About the Internet Group Management Protocol (IGMP) Snooping

Computers and network devices that want to receive multicast transmissions need to inform nearby routers that they will become members of a multicast group. The Internet Group Management Protocol (IGMP) is used to communicate this information. IGMP is also used to periodically check the multicast group for members that are no longer active. In the case where there is more than one multicast router on a sub network, one router is elected as the 'queried'. This router then keeps track of the membership of the multicast groups that have active members. The information received from IGMP is then used to determine if multicast packets should be forwarded to a given sub network or not. The router can check, using IGMP, to see if there is at least one member of a multicast group on a given subnet work. If there are no members on a sub network, packets will not be forwarded to that sub network.

Figure 74Multicast Service
GE 82-POE — Theory diagram (page 109)
Fig. 82 · Theory
Page 110 of the GE 82-POE user manual — IGMP Snooping
Page 110 · click to enlarge
Page 110
Figure 75Multicast flooding
GE 82-POE — IGMP Snooping diagram (page 110)
Fig. 83 · IGMP Snooping
Figure 76IGMP Snooping multicast stream control
GE 82-POE — IGMP Snooping diagram (page 110)
Fig. 84 · IGMP Snooping
Page 111 of the GE 82-POE user manual — IGMP Snooping
Page 111 · click to enlarge
Page 111

IGMP Versions 1 and 2

Multicast groups allow members to join or leave at any time. IGMP provides the method for members and multicast routers to communicate when joining or leaving a multicast group.

IGMP version 1 is defined in RFC 1112. It has a fixed packet size and no optional data.

The format of an IGMP packet is shown below:

0 8 16 31

Type Response Time Checksum

Group Address (all zeros if this is a query).

The IGMP Type codes are shown below:

0x11 Membership Query (if Group Address is 0.0.0.0).

0x11 Specific Group Membership Query (if Group Address is Present).

0x16 Membership Report (version 2).

0x17 Leave a Group (version 2).

0x12 Membership Report (version 1).

IGMP packets enable multicast routers to keep track of the membership of multicast groups, on their respective sub networks. The following outlines what is communicated between a multicast router and a multicast group member using IGMP.

A host sends an IGMP "report" to join a group.

A host will never send a report when it wants to leave a group (for version 1).

A host will send a "leave" report when it wants to leave a group (for version 2).

Multicast routers send IGMP queries (to the all-hosts group address: 224.0.0.1) periodically to see whether any group members exist on their sub networks. If there is no response from a particular group, the router assumes that there are no group members on the network.

IGMP Message Format · Octets · Type Meaning

Page 112 of the GE 82-POE user manual — IGMP Snooping
Page 112 · click to enlarge
Page 112

The Time-to-Live (TTL) field of query messages is set to 1 so that the queries will not be forwarded to other sub networks.

IGMP version 2 introduces some enhancements such as a method to elect a multicast queried for each LAN, an explicit leave message, and query messages that are specific to a given group.

The states a computer will go through to join or to leave a multicast group are shown below:

Figure 77IGMP State Transitions

Leave Group (Stop Timer) Leave Group Join Group (Send Report

(Start Timer) Report Received

(Stop Timer) Timer Expried

A router, or multicast-enabled switch, can periodically ask their hosts if they want to receive multicast traffic. If there is more than one router/switch on the LAN performing IP multicasting, one of these devices is elected "querier" and assumes the role of querying the LAN for group members. It then propagates the service requests on to any upstream multicast switch/router to ensure that it will continue to receive the multicast service.

Show 7 more labels / short text on this page
Non-Member · Start Timer) · Query Received · Delaying Member · Idle Member · (Send report) · IGMP Querier
Page 113 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 113 · click to enlarge
Page 113

IGMP Configuration

The Switch support IP multicast, you can enable IGMP protocol on web management's switch setting advanced page, then the IGMP snooping information displays. IP multicast addresses range are from 224.0.0.0 through 239.255.255.255.

Figure 78IGMP Configuration interface
GE 82-POE — IGMP Configuration diagram (page 113)
Fig. 85 · IGMP Configuration

This page includes the following fields:

OBJECT DESCRIPTION

IGMP Protocol Enable or disable the IGMP protocol.

IGMP Fastleave Enable or disable Fast Leave on the port.

IGMP Querier Enable or disable the IGMP query function. The IGMP query information will be displayed in IGMP status section.

NOTE: Fast Leave: The Managed Switch can be configured to immediately delete a member port of a multicast service if a leave packet is received at that port and the fastleave function is enabled for the parent VLAN. This allows the Managed witch to remove a port from the multicast forwarding table without first having to send an IGMP group-specific query to that interface.

Page 114 of the GE 82-POE user manual — Understand QOS
Page 114 · click to enlarge
Page 114

QoS Configuration

Understand QOS

Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as multi-media, video, protocol- specific, time critical, and file-backup traffic.

QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your data and allows you to prioritize certain applications across your network. You can define exactly how you want the switch to treat selected applications and types of traffic.

You can use QoS on your system to:

  • Control a wide variety of network traffic by:
  • Classifying traffic based on packet attributes.
  • Assigning priorities to traffic (for example, to set higher priorities to time-critical or business-critical applications).
  • Applying security policy through traffic filtering.
  • Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by minimizing delay and jitter.
  • Improve performance for specific types of traffic and preserve performance as the amount of traffic grows.
  • Reduce the need to constantly add bandwidth to the network.
  • Manage network congestion.

The QoS page of the Switch contains three types of QoS mode - the CoS mode, TOS mode or Port-based mode can be selected. Both the three mode rely on predefined fields within the packet to determine the output queue.

  • CoS / 802.1p Tag Priority Mode -The output queue assignment is determined by the IEEE 802.1p VLAN priority tag.
  • TOS / DSCP Mode - The output queue assignment is determined by the TOS or DSCP field in the IP packets.
  • Port-Based Priority Mode - Any packet received from the specified high priority port will treated as a high priority packet.
Page 115 of the GE 82-POE user manual — QoS Configuration
Page 115 · click to enlarge
Page 115

QoS Configuration

QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems. When CoS/802.1p Tag Priority is applied, the Switch recognizes 802.1Q VLAN tag packets and extracts the VLAN tagged packets with User Priority value.

802.1Q Tag and 802.1p priority

User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits

2 bytes 2 bytes

Source Address VLAN TAG Ethernet

6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes

Set up the COS priority level. With the drop-down selection item of Priority Type above being selected as COS only/COS first, this control item will then be available to set the queuing policy for each port.

Priority Queue Service settings

QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In 802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.

The Switch supports Static Port Ingress priority and four queues. The screen in Figure 79 appears.

Show 7 more labels / short text on this page
TPID (Tag Protocol · TCI (Tag Control · Identifier) · Information) · Preamble Destination · Type Data FCS · Address
Page 116 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 116 · click to enlarge
Page 116
Figure 79QoS Configuration - 802.1Priority
GE 82-POE — QoS Configuration diagram (page 116)
Fig. 86 · QoS Configuration

This page includes the following fields:

OBJECT DESCRIPTION

First Come First Service The sequence of packets sent is dependant on arrival order.

All High before Low The high priority packets are sent before low priority packets.

Select the preference given to packets in the switch's higher-priority queue. These options represent the number of higher priority packets sent before one lower priority packet is sent.

For example, 8 Highest : 4 SecHigh : 2 SecLow : 1 Lowest means that the switch sends 8 highest priority packets before sending 4 second high priority packet, before sending 2 second low priority packet, before sending 1 lowest priority packet.

802.1p priority [0-7] Set up the COS priority level 0-7—High, Middle, Low, Lowest.

Weighted Round Robin

Page 117 of the GE 82-POE user manual — TOS/DSCP
Page 117 · click to enlarge
Page 117

Configure the priority level for each port. With the drop-down selection item of Priority Type above being selected as Port-based, this control item will then be available to set the queuing policy for each port.

Figure 80QoS Configuration - Port-Based Priority
GE 82-POE — TOS/DSCP diagram (page 117)
Fig. 87

This page includes the following fields:

OBJECT DESCRIPTION

Port Number: Indicates port 1 to port 26.

Port Priority: Each port has 8 priority levels—0-7 or Disable to be chosen. 7 is the highest priority.

TOS/DSCP

TOS/DSCP priority is obtained through a 6-bit Type-of-Service (TOS) or Differentiated Service Code Point (DSCP) to 3-bit priority mapping.

The Type of Service (TOS) octet in the IPv4 header is divided into three parts; Precedence (3 bits), TOS (4 bits), and MBZ (1 bit). The Precedence bits indicate the importance of a packet, whereas the TOS bits indicate how the network should make tradeoffs between throughput, delay, reliability, and cost (as defined in RFC 1394). The MBZ bit (for "must be zero") is currently unused and is either set to zero or just ignored.

QoS PerPort Configuration

Page 118 of the GE 82-POE user manual — VLAN
Page 118 · click to enlarge
Page 118

0 1 2 3 4 5 6 7

Pv4 Packet Header Type of Service Octet

The four TOS bits provide 15 different priority values, however only five values have a defined meaning.

DiffServ Code Point (DSCP) - is the traffic prioritization bits within an IP header that are encoded by certain applications and/or devices to indicate the level of service required by the packet across a network. DSCP are defined in RFC2597 for classifying traffic into different service classes. The Managed Switch extracts the codepoint value of the DS field from IPv4 packets and identifies the priority of the incoming IP packets based on the configured priority.

4 bit 4 bit 6 bit 2 bit

VLAN

TAG

6 bytes 6 bytes 4 bytes 2 bytes 2 bytes 46-1517 bytes 4 bytes

The DSCP is six bits wide, allowing coding for up to 64 different forwarding behaviors. The DSCP retains backward compatibility with the three precedence bits so that non- DSCP compliant, TOS-enabled devices, will not conflict with the DSCP mapping. Based on network policies, different kinds of traffic can be marked for different kinds of forwarding.

The TOS/DSCP page provides fields for defining output queue to specific DSCP fields. When TCP/IP's TOS/DSCP mode is applied, the Managed Switch recognizes TCP/IP Differentiated Service Codepoint (DSCP) priority information from the DS-field defined in RFC2474.

Enable TOS/DSCP for traffic classification and then the DSCP to priority mapping column is configurable, as Figure 81 shows:

Show 12 more labels / short text on this page
Precedence TOS MBZ · VER=0100 Header · Size DiffServ RES · Ethernet · Preamble Destination · Source Address · Type · Data FCS · Address · (Optional) · (0800) · TOS/DSCP Configuration
Page 119 of the GE 82-POE user manual — DSCP
Page 119 · click to enlarge
Page 119
Figure 81QoS Configuration - TOS Priority
GE 82-POE — TOS/DSCP diagram (page 119)
Fig. 88

This page includes the following fields:

OBJECT DESCRIPTION

TOS/DSCP Enable / Disable internal traffic class ( 0-7) to map the corresponding IP DSCP value.

The values of the IP DSCP header field within the incoming packet.

DSCP

Specify which 802.1p priority to map the corresponding IP DSCP.

The value is 0-7.

Set up IP TOS / DSCP mapping to 802.1p priority when receiving IPv4/IPv6 packets, the Managed Switch allows to by port configuring the QoS Status. This TOS/DSCP Port Configuration page is to configure the IP TOS/DSCP mapping on the port and display the current port status. The screen in Figure 82 appears.

Priority · TOS/DSCP Port Configuration

Page 120 of the GE 82-POE user manual — Access Control List
Page 120 · click to enlarge
Page 120
Figure 82QoS Configuration - TOS/DSCP Port Status
GE 82-POE — Access Control List diagram (page 120)
Fig. 89 · Access Control List

This page includes the following fields:

OBJECT DESCRIPTION

Port Number Indicates port 1 to port 26.

TOS/DSCP Status Enable / Disable TOS/DSCP map to 802.1p priority on specify port.

Access Control List

The Access Control List (ACL) is a concept in computer security used to enforce privilege separation. It is a means of determining the appropriate access rights to a given object depending on certain aspects of the process that is making the request, principally the process's user identifier. Access Control List (ACL) is a mechanism that implements access control for a system resource by listing the identities of the system entities that are permitted or denied to access the resource. The screen in following figure appears.

Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be used to block packets by maintaining a table of packet fragments indexed by source and destination IP address, protocol, and so on.

Packet Type/Bindings can be selected to ACL for Ipv4 or Non-Ipv4.

Page 121 of the GE 82-POE user manual — OBJECT DESCRIPTION DEFAULT VALUE
Page 121 · click to enlarge
Page 121
Figure 83Access Control List (ACL) Web Page screen
GE 82-POE — Access Control List diagram (page 121)
Fig. 90 · Access Control List

This page includes the following fields:

OBJECT DESCRIPTION DEFAULT VALUE

Group ID 1 - 247 (max. 247 ACL group).

Action Permit / Deny.

  • Permit: Permit packet cross switch.
  • Deny: Drop packet.

VLAN Any / VID.

  • Any: Any VLAN id.
  • VID: 1-4094. A certain VLAN id.

Packet Type IPv4 / Non-IPv4 / Binding

  • IPv4: Set Ipv4 packet field.
  • Non-IPv4: Set non-Ipv4 packet field.
  • Binding: Set binding entry.
Show 4 more labels / short text on this page
IPv4 ACL · Permit · Any · IPv4
Page 122 of the GE 82-POE user manual — OBJECT DESCRIPTION DEFAULT VALUE
Page 122 · click to enlarge
Page 122

OBJECT DESCRIPTION DEFAULT VALUE

Src IP Address Set this field if Packet Type is IPv4, else ignore.

Any / IP and Mask

  • Any: Any IP address.
  • IP : A certain IP address.
Mask***.***.***.***

* is represent a digit from 0-9,

*** is range from 0 to 255

Dst IP Address Set this field if Packet Type is IPv4, else ignore.

Any / IP and Mask

Any: Any IP address.

IP : A certain IP address.

Mask***.***.***.***

* is represent a digit from 0-9,

*** is range from 0 to 255

IP Fragment Set this field if Packet Type is IPv4, else ignore.

Uncheck: Not check IP fragment field.

Check: Check IP fragment field.

L4 Protocol Set this field if Packet Type is IPv4, else ignore.

Any / ICMP(1) / IGMP(2) / TCP(6) / UDP(17)

Protocol Set this field if Packet Type is IPv4, else ignore.

If protocol not find in L4 Protocol field, you can direct assign number.

TCP Set this field if Packet Type is IPv4, else ignore.

Any / FTP(21) / HTTP(80)

Port Set this field if Packet Type is IPv4, else ignore.

If TCP port not find in TCP field, you can direct assign number.

UDP Set this field if Packet Type is IPv4, else ignore.

Any / DHCP(67) / TFTP(69) / NetBios(137)

Show 8 more labels / short text on this page
Any · Any · Uncheck · Uncheck / Check · Any · Any · 0-65535 · Any
Page 123 of the GE 82-POE user manual — OBJECT DESCRIPTION DEFAULT VALUE
Page 123 · click to enlarge
Page 123

OBJECT DESCRIPTION DEFAULT VALUE

Port Set this field if Packet Type is IPv4, else ignore.

If UDP port not find in UDP field, you can direct assign number.

Port Id Source port id, from 1-26, 0 means don’t care. 0

Current List You create ACL and Binding groups.

In Packet Type/Binding box should select Non-IPv4

OBJECT DESCRIPTION DEFAULT VALUE

Group ID 1 - 247 (max. 247 ACL group)

Action Permit / Deny.

  • Permit: Permit packet cross switch.
  • Deny: Drop packet.

VLAN Any / VID.

  • Any: Any VLAN ID.
  • VID: 1-4094. A certain VLAN ID.

Packet Type IPv4 / Non-IPv4 / Binding

  • IPv4: Set Ipv4 packet field.
  • Non-IPv4: Set non-Ipv4 packet field.
  • Binding: Set binding entry.

Set this field if Packet Type is Non-IPv4, else ignore.)

Any / ARP(0x0806) / IPX(0x8137)

Type Set this field if Packet Type is Non-IPv4, else ignore.)

If ether type not find in Ether Type field, you can direct assign number.

Current List You create ACL and Binding groups.

Show 8 more labels / short text on this page
0-65535 · Non-IPv4 ACL · Permit · Any · IPv4 · Ether Type · Any · 0-0xFFFF
Page 124 of the GE 82-POE user manual — OBJECT DESCRIPTION DEFAULT VALUE
Page 124 · click to enlarge
Page 124

Let a device that has specific IP address and MAC address use the network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match.

Use binding function; we should enable it first in following page.

In Packet Type/Binding box should select Binding.

OBJECT DESCRIPTION DEFAULT VALUE

Group ID 1 - 247 (max. 247 ACL group)

Action Permit / Deny.

  • Permit : Permit packet cross switch.
  • Deny: Drop packet.

VLAN Any / VID.

  • Any: Any Vlan id.
  • VID: 1-4094. A certain vlan id.

Packet Type IPv4 / Non-IPv4 / Binding

  • IPv4: Set Ipv4 packet field.
  • Non-IPv4: Set non-Ipv4 packet field.
  • Binding: Set binding entry.

MAC Address **:**:**:**:**:**

00:11:22:33:44:55

* is represent a digit from 0-9 and A-F,

*** is range from 0 to FF.

IP Address ***.***.***.***

0.0.0.0

* is represent a digit from 0-9,

*** is range from 0 to 255.

Port Id Source port id, from 1-26. 1

Current List You create ACL and Binding groups.

Show 4 more labels / short text on this page
Binding · Permit · Any · IPv4
Page 125 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 125 · click to enlarge
Page 125

MAC Limit

MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table are the result of first-come-first-save policy. Once a MAC address is stored in the MAC address table, it stays in until it is aged out. When an "opening" is available, the switch stored the first new MAC address it sees in that opening. All packets from MAC addresses not in the MAC address table should be blocked.

MAC Limit Configuration

The Layer 2 MAC Limit function can be per-port configured for security management purposes. When the port is in MAC Limit mode, the port will be "locked" without permission of address learning. Only the incoming packets with Source MAC already existing in the address table can be forwarded normally. User can disable the port from learning any new MAC addresses.

Figure 84MAC Limit - Configure MAC Limit
GE 82-POE — MAC Limit Configuration diagram (page 125)
Fig. 91 · MAC Limit Configuration

This page includes the following fields:

OBJECT DESCRIPTION

MAC Limit Enable or disable MAC limit function for the Managed Switch.

Port Number Indicate port 1 to port 26.

Limit The maximum number of per-port MAC addresses to be learned (1-64, 0 to disable this port's MAC limit function).

Page 126 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 126 · click to enlarge
Page 126

MAC Limit Port Status

This table displays current MAC Limit status of each port.

Figure 85MAC Limit - MAC Limit Port Status
GE 82-POE — MAC Limit Port Status diagram (page 126)
Fig. 92 · MAC Limit Port Status

This page includes the following fields:

OBJECT DESCRIPTION

Port Number Indicates port 1 to port 26.

Limit Display the current MAC Limit configuration and status of each port.

Page 127 of the GE 82-POE user manual — Understanding IEEE 802.1X Port-Based Authentication
Page 127 · click to enlarge
Page 127

802.1X Configuration

802.1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority, like the user name and password that are verified by an authentication server (such as RADIUS server).

Understanding IEEE 802.1X Port-Based Authentication

The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server authenticates each client connected to a switch port before making available any services offered by the switch or the LAN.

Until the client is authenticated, 802.1X access control allows only Extensible Authentication Protocol over LAN (EAPOL) traffic through the port to which the client is connected. After authentication is successful, normal traffic can pass through the port.

This section includes this conceptual information:

  • Device Roles
  • Authentication Initiation and Message Exchange
  • Ports in Authorized and Unauthorized States
  • Device Roles

With 802.1X port-based authentication, the devices in the network have specific roles as shown below.

Page 128 of the GE 82-POE user manual — 802.1X Configuration
Page 128 · click to enlarge
Page 128
Figure 86802.1x device role
GE 82-POE — 802.1X Configuration diagram (page 128)
Fig. 93 · 802.1X Configuration

Client-the device (workstation) that requests access to the LAN and switch services and responds to requests from the switch. The workstation must be running 802.1X- compliant client software such as that offered in the Microsoft Windows XP operating system. (The client is the supplicant in the IEEE 802.1X specification.)

  • Authentication server-performs the actual authentication of the client. The authentication server validates the identity of the client and notifies the switch whether or not the client is authorized to access the LAN and switch services. Because the switch acts as the proxy, the authentication service is transparent to the client. In this release, the Remote Authentication Dial-In User Service (RADIUS) security system with Extensible Authentication Protocol (EAP) extensions is the only supported authentication server; it is available in Cisco Secure Access Control Server version 3.0. RADIUS operates in a client/server model in which secure authentication information is exchanged between the RADIUS server and one or more RADIUS clients.
  • Switch (802.1X device)-controls the physical access to the network based on the authentication status of the client. The switch acts as an intermediary (proxy) between the client and the authentication server, requesting identity information from the client, verifying that information with the authentication server, and relaying a response to the client. The switch includes the RADIUS client, which is responsible for encapsulating and decapsulating the Extensible Authentication Protocol (EAP) frames and interacting with the authentication server. When the switch receives EAPOL frames and relays them to the authentication server, the Ethernet header is stripped and the remaining EAP frame is re-encapsulated in the RADIUS format. The EAP frames are not modified or examined during encapsulation, and the authentication server must support EAP within the native frame format. When the switch receives frames from the authentication server, the server's frame header is removed, leaving the EAP frame, which is then encapsulated for Ethernet and sent to the client.
Page 129 of the GE 82-POE user manual — 802.1X Configuration
Page 129 · click to enlarge
Page 129
  • Authentication Initiation and Message Exchange

The switch or the client can initiate authentication. If you enable authentication on a port by using the dot1x port-control auto interface configuration command, the switch must initiate authentication when it determines that the port link state transitions from down to up. It then sends an EAP-request/identity frame to the client to request its identity (typically, the switch sends an initial identity/request frame followed by one or more requests for authentication information). Upon receipt of the frame, the client responds with an EAP-response/identity frame.

However, if during bootup, the client does not receive an EAP-request/identity frame from the switch, the client can initiate authentication by sending an EAPOL-start frame, which prompts the switch to request the client's identity.

NOTE: If 802.1X is not enabled or supported on the network access device, any EAPOL frames from the client are dropped. If the client does not receive an EAP- request/identity frame after three attempts to start authentication, the client transmits frames as if the port is in the authorized state. A port in the authorized state effectively means that the client has been successfully authenticated.

When the client supplies its identity, the switch begins its role as the intermediary, passing EAP frames between the client and the authentication server until authentication succeeds or fails. If the authentication succeeds, the switch port becomes authorized.

The specific exchange of EAP frames depends on the authentication method being used. "Figure 87" shows a message exchange initiated by the client using the One- Time-Password (OTP) authentication method with a RADIUS server.

Page 130 of the GE 82-POE user manual — 802.1X Configuration
Page 130 · click to enlarge
Page 130
Figure 87EAP message exchange
GE 82-POE — 802.1X Configuration diagram (page 130)
Fig. 94 · 802.1X Configuration
  • Ports in Authorized and Unauthorized States

The switch port state determines whether or not the client is granted access to the network. The port starts in the unauthorized state. While in this state, the port disallows all ingress and egress traffic except for 802.1X protocol packets. When a client is successfully authenticated, the port transitions to the authorized state, allowing all traffic for the client to flow normally.

If a client that does not support 802.1X is connected to an unauthorized 802.1X port, the switch requests the client's identity. In this situation, the client does not respond to the request, the port remains in the unauthorized state, and the client is not granted access to the network.

In contrast, when an 802.1X-enabled client connects to a port that is not running the 802.1X protocol, the client initiates the authentication process by sending the EAPOL- start frame. When no response is received, the client sends the request for a fixed number of times. Because no response is received, the client begins sending frames as if the port is in the authorized state

If the client is successfully authenticated (receives an Accept frame from the authentication server), the port state changes to authorized, and all frames from the authenticated client are allowed through the port. If the authentication fails, the port remains in the unauthorized state, but authentication can be retried. If the

Page 131 of the GE 82-POE user manual — System Configuration
Page 131 · click to enlarge
Page 131

authentication server cannot be reached, the switch can retransmit the request. If no response is received from the server after the specified number of attempts, authentication fails, and network access is not granted.

When a client logs off, it sends an EAPOL-logoff message, causing the switch port to transition to the unauthorized state.

If the link state of a port transitions from up to down, or if an EAPOL-logoff frame is received, the port returns to the unauthorized state.

System Configuration

802.1x makes use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide a means of authenticating and authorizing devices attached to a LAN port that has point-to-point connection characteristics, and of preventing access to that port in cases in which the authentication and authorization process fails.

To enable 802.1x, from System \ System Information \ Misc Config then you still to fill in the authentication server information:

Figure 88System information \ Misc Configuration\ 802.1x Protocol
GE 82-POE — System Configuration diagram (page 131)
Fig. 95 · System Configuration
Page 132 of the GE 82-POE user manual — 802.1x Port Configuration
Page 132 · click to enlarge
Page 132

After enabling the IEEE 802.1X function, you can configure the parameters of this function.

Figure 89802.1x System Configuration interface
GE 82-POE — 802.1x Port Configuration diagram (page 132)
Fig. 96 · 802.1x Port Configuration

This page includes the following fields:

OBJECT DESCRIPTION

IEEE 802.1x Protocol: Enable or disable 802.1x protocol.

Radius Server IP: Assign the RADIUS Server IP address.

Server Port: Set the UDP destination port for authentication requests to the specified RADIUS Server.

Accounting Port: Set the UDP destination port for accounting requests to the specified RADIUS Server.

Set an encryption key for using during authentication sessions with the specified RADIUS server. This key must match the encryption key used on the RADIUS Server.

Shared Key:

NAS, Identifier: Set the identifier for the RADIUS client.

802.1x Port Configuration

In this page, you can select the specific port and configure the authorization state. The state provides No Authorization, Force Authorized, Force unauthorized, and Authorize.

Page 133 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 133 · click to enlarge
Page 133
Figure 90802.1x Per Port Setting interface
GE 82-POE — 802.1x Port Configuration diagram (page 133)
Fig. 97 · 802.1x Port Configuration

This page includes the following fields:

OBJECT DESCRIPTION

FU (Force Unauthorized) The specified port is required to be held in the unauthorized state.

FA (Force Authorized) The specified port is required to be held in the authorized state.

The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server.

No The specified port works without complying with 802.1x protocol.

Authorize

Page 134 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 134 · click to enlarge
Page 134

Misc Configuration

In this page, you can change the default configuration for the 802.1x standard:

Figure 91802.1x Misc Configuration interface
GE 82-POE — Misc Configuration diagram (page 134)
Fig. 98 · Misc Configuration

This page includes the following fields:

OBJECT DESCRIPTION

Used to define periods of time during which it will not attempt to acquire a supplicant.

Quiet Period:

Default time is 60 seconds.

Set the period the port waits for retransmit next EAPOL PDU during an authentication session.

TX Period:

Default value is 30 seconds.

Set the period of time the switch waits for a supplicant response to an EAP request.

Supplicant Timeout:

Default value is 30 seconds.

Set the period of time the switch waits for a server response to an authentication request.

Server Timeout:

Default value is 30 seconds.

Set the number of authentication that must time-out before authentication fails and the authentication session ends.

Max Requests:

Default value is 2 times.

Set the period of time which clients connected must be re- authenticated.

Reauth period:

Default value is 3600 seconds.

Page 135 of the GE 82-POE user manual — Power Management
Page 135 · click to enlarge
Page 135

Power Over Ethernet

Providing up to 24 PoE, in-line power interface, the GE-DS-82-PoEPoE Switch can easily build a power central-controlled IP phone system, IP Camera system, AP group for the enterprise. For instance, 24 camera / AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the office. Without the power-socket limitation, the PoE Switch makes the installation of cameras or WLAN AP more easily and efficiently.

Power over Ethernet Powered Device

Voice over IP phones

Enterprise can install POE VoIP Phone, ATA and other Ethernet/non- Ethernet end-devices to the central where UPS is installed for un-interrupt power system and power control system.

Wireless LAN Access Points

Museum, Sightseeing, Airport, Hotel, Campus, Factory, Warehouse can install the Access Point any where with no hesitation

Enterprise, Museum, Campus, Hospital, Bank, can install IP Camera without limits of install location – no need electrician to install AC sockets.

GE 82-POE — Power over Ethernet Powered Device diagram (page 135)
Fig. 99 · Power over Ethernet Powered Device

PoE Splitter split the PoE 48V DC over the Ethernet cable into 5/9/12V DC power output. It frees the device deployment from restrictions due to power outlet locations, which eliminate the costs for additional AC wiring and reduces the installation time.

Power Management

In a power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN infrastructure to powered devices (PDs), which are connected to ports. Under some conditions, the total output power required by PDs can exceed the maximum available power provided by the PSU. The system may a prior be planed with a PSU capable of supplying less power than the total potential power consumption of all the PoE ports in the system. In order to maintain the majority of ports active, power management is implemented.

Show 6 more labels / short text on this page
3-5 watts · 6-12 watts · IP Surveillance · 10-12 watts · PoE Splitter · 3-12 watts
Page 136 of the GE 82-POE user manual — Power Over Ethernet
Page 136 · click to enlarge
Page 136

The PSU input power consumption is monitored by measuring the voltage and current. The input power consumption is equal to the system's aggregated power consumption. The power management concept allows all ports to be active and activates additional ports, as long as the aggregated power of the system is lower than the power level at which additional PDs cannot be connected. When this value is exceeded, ports will be deactivated, according to user-defined priorities. The power budget is managed according to the following user-definable parameters: maximum available power, ports priority, the maximum allowable power per port.

The Over Temperature Protection of the PoE Switch offers a safety and stable PoE operating by limit the output power according to detected temperature to prevent destructive breakdown due to un-expected overheating.

This section provides PoE (Power over Ethernet) Configuration and PoE output status of the PoE Switch, the screen in Figure 92 appears.

Figure 92PoE Configuration
GE 82-POE — Power Over Ethernet diagram (page 136)
Fig. 100 · Power Over Ethernet
Page 137 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 137 · click to enlarge
Page 137

This page includes the following fields:

OBJECT DESCRIPTION

PoE PSU Status PoE PSU Status shows status of power supply for PoE output.

PoE Temperature Unit 1 Display the current operating temperature of PoE chip unit 1.

The unit 1 is in charge of PoE Port-1-Port-12

PoE Temperature Unit 2 Display the current operating temperature of PoE chip unit 2.

The unit 1 is in charge of PoE Port-13-Port-24

Enable / Disable over temperature protection.

When the PoE temperature unit 1 / unit2 over 70 degree C then PoE power budget will be changed by 3 segments as following.

Over 70 Degree C power budget 180 Watts

Over 73 Degree C power budget 170 Watts

Over 76 Degree C power budget 160 Watts

Power limit mode Allow you to configure the power limit mode of Web Smart Device. You can choose :

Port Priority Deliver PoE power by port priority setting

Total Limit. Set limit value of the total POE port provided power to the PDs.

Power Allocation Show the total watts usage of PoE Switch.

PoE Function Can enable or disable the PoE function.

Priority Set port priority for the POE power management

It can choose the “port priority”, value is :

High priority is “Critical”.

Device class Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes. A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by Table 4.1.

Current(mA) It shows the PoE device current Amp.

Consumption [W] It shows the PoE device current watt.

Show 4 more labels / short text on this page
Over Temperature Protection · Critical · High · Low
Page 138 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 138 · click to enlarge
Page 138

OBJECT DESCRIPTION

Power Limit It can limit the port PoE supply watts.

Per port maximum value must less 15.4, total ports values must less than the Power Reservation value.

Once power overload detected, the port will auto shut down and keep on detection mode until PD’s power consumption lower than the power limit value.

A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is to provide information about the maximum power required by the PD during operation. Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes.

A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by the table below.

Class Usage Range of maximum power used by the PD

0 Default 0.44 to 12.95 Watts

1 Optional 0.44 to 3.84 Watts

2 Optional 3.84 to 6.49 Watts

3 Optional 6.49 to 12.95 Watts

4 Not Allowed Reserved for Future Use

PD Classifications

Page 139 of the GE 82-POE user manual — DHCP Relay and Option 82
Page 139 · click to enlarge
Page 139

DHCP Relay and Option 82

The Relay Agent Information option (Option82) is inserted by the DHCP relay agent when forwarding client-originated DHCP packets to a DHCP server (RFC 3046). Servers recognizing the Relay Agent Information option may use the information to implement IP address or other parameter assignment policies.

The DHCP Relay can forward the DHCP broadcast packets to a DHCP server in a different subnet (RFC 1542). So DHCP server can provide IP addresses to clients spanning multiple subnets instead of deploying a DHCP server on every subnet.

Configuring DHCP Relay & Option82

To configure DHCP Option82

1. Enable the global option82 function: select DHCP Option82 enable.
2. Enable port option82 function: select Option82 checkbox for special port.
3. Select DHCP Router Port.
4. Click Apply.

To configure DHCP Relay

1. Enable global Relay function: select DHCP Relay enable "Enable".
2. Enable port Relay function: Type the IP addresses of the DHCP "Relay IP".
3. DHCP Server offers an IP address to client from its list of scopes, which subnet is same as the Relay IP.
4. Select DHCP Router Port.
5. Click Apply.
Page 140 of the GE 82-POE user manual — LLDP
Page 140 · click to enlarge
Page 140
Figure 93DHCP Relay & Option 82
GE 82-POE — LLDP diagram (page 140)
Fig. 101

This page includes the following fields:

OBJECT DESCRIPTION

DHCP Option 82 Enable global option82 function

DHCP Relay Enable global Relay function

DHCP Option 82 Router Port

DCHP Opt.82 Port Identify Port-1 to Port-10 to configure DHCP option 82

Option Enable port option82 function on selected port.

Relay IP Type the IP addresses of the DHCP "Relay IP".

LLDP

Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on the local broadcast domain. LLDP is a Layer 2 protocol that uses periodic broadcasts to advertise information about the sending device. Advertised information is represented in Type Length Value (TLV) format according to the IEEE 802.1ab standard, and can include details such as device identification, capabilities and configuration settings. LLDP also defines how to store and maintain information gathered about the neighboring network nodes it discovers.

Page 141 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 141 · click to enlarge
Page 141

Use this page to change LLDP parameters.

Figure 94LLDP Configuration
GE 82-POE — LLDP diagram (page 141)
Fig. 102

This page includes the following fields:

OBJECT DESCRIPTION

LLDP Status Enable/Disable LLDP.

LLDP hello time You can change LLDP hello time value. The time interval between the transmission LLDP info packets. Value range is from 5 to 32768. Default value is 30.

LLDP hold time You can change LLDP hold time value. (The hold time * the hello time) is the TTL time in the LLDP info packets. Value range is from 2 to 10. Default value is 4.

This page allows the user to inspect and configure the current LLDP port settings. The LLDP Configuration screen in Figure 95 appears.

LLDP Configuration · PerPort Configuration

Page 142 of the GE 82-POE user manual — OBJECT DESCRIPTION
Page 142 · click to enlarge
Page 142
Figure 95LLDP Per Port Configuration
GE 82-POE — LLDP diagram (page 142)
Fig. 103

This page includes the following fields:

OBJECT DESCRIPTION

LLDP Status Enable/Disable LLDP.

LLDP hello time You can change LLDP hello time value. The time interval between the transmission LLDP info packets. Value range is from 5 to 32768. Default value is 30.

LLDP hold time You can change LLDP hold time value. (The hold time * the hello time) is the TTL time in the LLDP info packets. Value range is from 2 to 10. Default value is 4.

Port Status You can change LLDP port status to Tx_only/Rx_only/Tx_and_Rx/Disable. Tx_only: LLDP transmit the packet of the port only. Rx_only: LLDP receive the packet of the port only. Tx_and_Rx: LLDP transmit and receive the packets of the port. Disable: LLDP do not transmit and receive the packets of the port.

Page 143 of the GE 82-POE user manual — Chapter 5 Console Management
Page 143 · click to enlarge
Page 143

Chapter 5 Console Management

Login in to the Console Interface

To configure the system via console mode, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type serial (console) port of the Managed Switch. The console port of the Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of Null Modem.

Please refer to the Administration Console section on page 28 to get more information about how to connect to the console interface of GE-DS-82-PoE with HyperTerminal on Microsoft Windows platform.

Once the terminal has connected to the device, power on the GE-DS-82-PoE, the terminal will display that it is running testing procedures.

Then, the following message asks the login password. The factory default password as following and the login screen in Figure 96 appears.

Usernameadmin
Passwordadmin
Page 144 of the GE 82-POE user manual — Login in to the Console Interface
Page 144 · click to enlarge
Page 144
Chapter 5Console Management
Figure 96GE-DS-82-PoEConsole Login screen
GE 82-POE — Login in to the Console Interface diagram (page 144)
Fig. 104 · Login in to the Console Interface

Username Max: 6, Min: 1 characters.

Password Max: 6, Min: 1 characters.

Only enter commands in lowercase letters in the console interface.

Page 145 of the GE 82-POE user manual — Configure IP address
Page 145 · click to enlarge
Page 145
Chapter 5Console Management

Configure IP address

The GE-DS-82-PoEManaged Switch is shipped with default IP address as following.

IP Address192.168.0.100
Subnet Mask255.255.255.0

To check the current IP address or modify a new IP address for the Switch, please use the procedures as follow:

Show the current IP address

1. On "Switch# " prompt, enter "configure".
2. On "Switch(config)# " prompt, enter "show ip".
3. The screen displays the current IP address, Subnet Mask and Gateway. As show in Figure 97.
Figure 97Show IP information screen
GE 82-POE — Configure IP address diagram (page 145)
Fig. 105 · Configure IP address
Page 146 of the GE 82-POE user manual — IP: 192.168.1.100
Page 146 · click to enlarge
Page 146
Chapter 5Console Management
1. On "Switch(config)# " prompt, enter the following command and press . As show in Figure 98.

Switch(config)# ip address 192.168.1.100 255.255.255.0

Switch(config)# ip default-gateway 192.168.1.254

The previous command would apply the follow settings for the Switch.

IP: 192.168.1.100

Subnet Mask255.255.255.0
Gateway192.168.1.254
Figure 98Set IP address screen
2. Repeat Step 1 to check if the IP address has changed.

If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Managed Switch through the new IP address.

Configure IP address

Page 147 of the GE 82-POE user manual — Commands Level
Page 147 · click to enlarge
Page 147
Chapter 5Console Management

You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.

Commands Level

The following table lists the CLI commands and description.

Modes Access Method Prompt Exit Method About This Model

The user commands available at the user level are a subset of those available at the privileged level.

User EXEC Begin a session with your switch. switch> Enter logout or quit.

Use this mode to:

  • Perform basic tests.
  • Display system information.

The privileged command is the advanced mode.

Enter the enable command while in User EXEC mode.

switch# Enter disable to exit.

Use this mode to

  • Display advanced function status
  • Save configuration

Use this mode to configure those parameters that are going to be applied to your switch.

Enter the configure command while in privileged EXEC mode.

To exit to privileged EXEC mode, enter exit or end

Privileged EXEC · Global Configuration · switch (config)#

Page 148 of the GE 82-POE user manual — Commands Level
Page 148 · click to enlarge
Page 148
Chapter 5Console Management
Page 149 of the GE 82-POE user manual — Chapter 6 Command Line Interface
Page 149 · click to enlarge
Page 149

Chapter 6 Command Line Interface

Operation Notice

To enter the "configuration" mode, you need to be in the privileged mode, and then types in the command configure:

Switch# configure · Switch (config) #

Page 150 of the GE 82-POE user manual — System Commands
Page 150 · click to enlarge
Page 150
Chapter 6Command Line Interface

Command Line Editing

<Ctrl>-B ; ← Moves the cursor back one character.

<Ctrl>-D Deletes the character at the cursor.

<Ctrl>-E Jumps to the end of the current command line.

<Ctrl>-F ; → Moves the cursor forward one character.

<Ctrl>-K Deletes from the cursor to the end of the command line.

<Ctrl>-N ; ↓ Enters the next command line in the command history.

<Ctrl>-P ; ↑ Enters the previous command line in the command history.

<Ctrl>-U Deletes from the cursor to the beginning of the command line.

<Ctrl> -W Deletes the last word typed.

<Esc> B Moves the cursor backward one word.

<Esc> D Deletes from the cursor to the end of the word.

<Esc> F Moves the cursor forward one word.

<Backspace> Delete the character before the cursor.

<Del> Delete the character at the cursor.

The following generic function keys provide functions in all of the menus:

Command Help

You may enter ? at any command mode, and the CLI will return all possible commands at that point, along with some description of the command.

System Commands

show running-config Display the running configuration of the switch.

Backup the switch configurations.

erase startup-config Reset to default factory settings at next boot time.

clear arp specifies the IP address to be cleared. If no IP address is entered, the entire ARP cache is cleared.

show arp Show the IP ARP translation table.

Ping Send ICMP ECHO_REQUEST to network hosts.

Parameters: specifies the number of repetitions. If not entered, it will continue to ping until you press -C to stop.

Key Function · Command Description · copy running-config startup- config

Page 151 of the GE 82-POE user manual — Port Configuration and show status
Page 151 · click to enlarge
Page 151
Chapter 6Command Line Interface

Switch Static Configuration

Port Configuration and show status

Description:

Turn the port state on or off.

Syntax:

port state []

Parameters:

<port-list> specifies the ports to be turn on or off. If not entered, all ports are turn on or off.

Description:

Set port negotiation.

Syntax:

port nego []

Parameters:

<port-list> specifies the ports to be set.If not entered, all ports are set.

Description:

Set port speed (in mbps) and duplex.

Syntax:

port speed []

Parameters:

<port-list> specifies the ports to be set. If not entered, all ports are set.

port state · port nego · port speed

Page 152 of the GE 82-POE user manual — Switch Static Configuration
Page 152 · click to enlarge
Page 152
Chapter 6Command Line Interface

Description:

Enable or disable port flow control.

Syntax:

port flow []

Parameters:

The first enables or disables flow control in full duplex mode.

The second enables or disables flow control in half duplex mode.

specifies the ports to be set. If not entered, all ports are set.

Description:

Set port effective ingress or egress rate.

Syntax:

port rate []

Parameters:

specifies the ingress or egress rate.

specifies the ports to be set. If not entered, all ports are set.

Description:

Set port priority.

Syntax:

port priority []

Parameters:

specifies the ports to be set. If not entered, all ports are set.

port flow · port rate · port priority

Page 153 of the GE 82-POE user manual — VLAN: DEFAULT
Page 153 · click to enlarge
Page 153
Chapter 6Command Line Interface

Description:

Set port jumbo frame. When port jumbo frame is enable, the port forward jumbo frame packet

Syntax:

port jumboframe []

Parameters:

specifies the ports to be set. If not entered, all ports are set.

Description:

Show port status, including port State, Link, Trunking, VLAN, Negotiation, Speed, Duplex, Flow control, Rate control ,Priority, Security, BSF control.

Switch(config)# show port status

Stateon
Linkdown
Trunkingnone

VLAN: DEFAULT

Prioritydisable
Securityoff
Stateon
Linkdown
Trunkingnone

VLAN: DEFAULT

Prioritydisable
Securityoff
Show 9 more labels / short text on this page
port jumboframe · show port status · ---------------------------------------------------------------------- · Port 1 Information · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · Port 2 Information · ---------------------------------------------------------------------- · ----------------------------------------------------------------------
Page 154 of the GE 82-POE user manual — Switch Static Configuration
Page 154 · click to enlarge
Page 154
Chapter 6Command Line Interface
Stateon
Linkdown

Description:

Show port statistics, including TxGoodPkt, TxBadPkt, RxGoodPkt, RxBadPkt, TxAbort, Collision, and DropPkt.

Parameters:

specifies the port to be shown.

Switch(config)# show port statistics

TxGoodPkt0
TxBadPkt0
RxGoodPkt0
RxBadPkt0
TxAbort0
Collision0
DropPkt0
TxGoodPkt0
TxBadPkt0
RxGoodPkt0
RxBadPkt0
TxAbort0
Collision0
Show 10 more labels / short text on this page
Port 3 Information · ---------------------------------------------------------------------- · --More-- · show port statistics · ---------------------------------------------------------------------- · Port 1 Information · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · Port 2 Information · ----------------------------------------------------------------------
Page 155 of the GE 82-POE user manual — Table of contents
Page 155 · click to enlarge
Page 155

Table of contents

Package Contentsp.6Product Descriptionp.6High Performance Wire-Speed Switchingp.6Cost-effective solution with SNMP monitor for Network deploymentp.7Remote and Centralize Management installationp.7Powerful Securityp.7Power over Ethernet of GE-DS-82-PoEp.8How to Use this Manualp.8Product Featuresp.8Physical Portp.8Product Specificationsp.11Hardware Descriptionp.15Switch Front Panelp.15LED Indicationsp.16Switch Rear Panelp.18Switch Installationp.20Desktop/Shelf Installationp.20Rack-mount Installationp.21SFP Transceiver Installationp.22Summaryp.27Requirementsp.27Management Access Overviewp.28Web Browser Managementp.29Web Browser Setupp.30SNMP-Based Network Managementp.32The Administration Consolep.32Direct Accessp.33Protocolsp.34Virtual Terminal Protocolsp.34Telnet Setupp.34SNMP Protocolp.36Management Architecturep.36About Web-based Managementp.37Requirementsp.38Logging on to the Switchp.39Main Web Pagep.40Panel Displayp.40Main Menup.41Systemp.42System Informationp.42IP Configurationp.45SNMP Configurationp.47SNMPv3 Viewp.52Firmware Upgradep.55Configuration Backupp.57Factory Defaultp.59Syslog Settingp.60Port Configurationp.60Port Statusp.63Port Statisticsp.63Port Snifferp.65Protected Portp.67VLAN Configurationp.68VLAN Overviewp.68Static VLAN Configurationp.71Port-Based VLANp.72802.1Q VLANp.75802.1Q VLANp.80GVRP VLANp.84GVRP Settingp.84Rapid Spanning Treep.87Theoryp.87Illustration of STPp.90STP Parametersp.92RSTP System Configurationp.93Port Configurationp.96Trunkingp.98Aggregator Settingp.99Aggregator Informationp.100State Activityp.104Forwarding and Filteringp.105Dynamic MAC Tablep.105Static MAC Tablep.106MAC Filteringp.107IGMP Snoopingp.109Theoryp.109IGMP Configurationp.113QoS Configurationp.114Understand QOSp.114QoS Configurationp.115TOS/DSCPp.117Access Control Listp.120MAC Limitp.125MAC Limit Configurationp.125MAC Limit Port Statusp.126802.1X Configurationp.127Understanding IEEE 802.1X Port-Based Authenticationp.127System Configurationp.131802.1x Port Configurationp.132Misc Configurationp.134Power Over Ethernetp.135Power over Ethernet Powered Devicep.135Power Managementp.135DHCP Relay and Option 82p.139LLDPp.140Login in to the Console Interfacep.143Configure IP addressp.145Commands Levelp.147Operation Noticep.149Command Line Editingp.150Command Helpp.150System Commandsp.150Switch Static Configurationp.151Port Configuration and show statusp.151Trunk Configurationp.155Trunking Commandsp.155LACP Commandsp.157VLAN Configurationp.159Virtual LANsp.159VLAN Mode: Port-basedp.160Advanced 802.1Q VLAN Configurationp.161Misc Configurationp.169Administration Configurationp.171Change Username / Passwordp.171IP Configurationp.172Reboot switchp.173Reset to Defaultp.173TFTP Update Firmwarep.174Restore Configure Filep.174Backup Configure Filep.175MAC limitp.176Port Mirroring Configurationp.177Quality of Servicep.178QoS Configurationp.178Per Port Priorityp.180MAC Address Configurationp.181STP/RSTP Commandsp.183SNMPp.188System Optionsp.188Community Stringsp.190Trap Managersp.191IGMPp.192802.1x Protocolp.194Access Control Listp.198Ipv4 ACL commandsp.198Non-Ipv4 ACL commandsp.201Bindingp.203SIP/SMAC binding commandsp.203Power over Ethernet Commands (GE DS-82-PoE)p.205Display System PoE statusp.205Configure PoE Over Temperature Protectionp.207Configure PoE - Systemp.207Configure PoE -- Portp.209Address Tablep.213Learningp.213Forwarding & Filteringp.213Store-and-Forwardp.214Auto-Negotiationp.214What is PoE?p.215PoE System Architecturep.216How Power is Transferred Through the Cablep.216The PoE Provision Processp.218Stages of powering up a PoE linkp.218Line Detectionp.219Classificationp.219Start-upp.219Operationp.219Power Overloadsp.220Power Disconnection Scenariosp.220DC Disconnectp.220AC Disconnectp.220Switch's RJ-45 Pin Assignmentsp.22310/100Mbps, 10/100Base-TXp.224
Page 156 of the GE 82-POE user manual — Trunking Commands
Page 156 · click to enlarge
Page 156
Chapter 6Command Line Interface

21 | off | 1

22 | off | 1

25 | off | 1

26 | off | 1

Trk1 | off | 1

Trunk Configuration

Trunk allows the switch to combine ports so that they function like a single high- speed link. It can be used to increase the bandwidth to some devices to provide a high-speed link. For example, trunk is useful when making connections between switches or connecting servers to the switch. Trunk can also provide a redundant link for fault tolerance. If one link in the trunk failed, the switch can balance the traffic among the remaining links.

All ports in the same trunk group will be treated as a single port. If a trunk group exists, the ports belonging to that trunk will be replaced by "TRUNK #" in the VLAN configuration screen. The following example configures port 25-26 as "TRUNK 1."

Trunking Commands

Description:

Show trunking information.

Group ID | LACP | Ports | LACP Active

1 | Yes | 23,24 | 23,24

show trunks · Switch(config)# show trunk · + + +

Page 157 of the GE 82-POE user manual — LACP Commands
Page 157 · click to enlarge
Page 157
Chapter 6Command Line Interface

Description:

Add a new trunk group.

Syntax:

trunk add <trunk-id> <lacp | no-lacp> <port-list> <active-port-list>

Parameters:

<trunk-id> specifies the trunk group to be added.

Description:

Specifies the added trunk group to be LACP enabled.

Syntax:

no-lacp specifies the added trunk group to be LACP disabled.

Parameters:

<port-list> specifies the ports to be set.

<active-port-list> specifies the ports to be set to LACP active.

Description:

Delete an existing trunk group.

Syntax:

Parameters:

<trunk-id> specifies the trunk group to be deleted

LACP Commands

Description:

Enable/disable LACP.

Show 6 more labels / short text on this page
trunk add · lacp · lacp · no trunk · no trunk <trunk-id> · [no] lacp
Page 158 of the GE 82-POE user manual — LACP Commands
Page 158 · click to enlarge
Page 158
Chapter 6Command Line Interface

Description:

Set LACP system priority.

Syntax:

lacp system-priority <1..65535>

Parameters:

<1..65535> specifies the LACP system priority.

Description:

Set LACP system priority to the default value 32768.

Description:

Show LACP enable/disable status and system priority.

Description:

Show LACP information.

Switch(config)# show lacp status

LACP is enabled.

LACP system priority32768

Description:

Show LACP aggregator information.

Syntax:

show lacp agg <trunk-id>

Parameters:

<trunk-id> specifies the trunk group to be shown.

Show 5 more labels / short text on this page
lacp system-priority · no lacp system-priority · show lacp status · show lacp · show lacp agg
Page 159 of the GE 82-POE user manual — Virtual LANs
Page 159 · click to enlarge
Page 159
Chapter 6Command Line Interface

Description:

Show LACP information by port.

Syntax:

show lacp port <port-id>

Parameters:

<port-id> specifies the port to be shown.

VLAN Configuration

Virtual LANs

A Virtual LAN (VLAN) is a logical network group that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN within a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still plugged into the same switch physically. A station can belong to more than one VLAN group. VLAN prevents users from accessing network resources of another on the same LAN, thus the users can not see the hard disks and printers of another user in the same building. VLAN can also increase the network performance by reducing the broadcast traffic and enhance the security of the network by isolating groups.

The GE-DS-82-PoEsupports two types of VLANs:

  • Port-based
  • IEEE 802.1Q (tag) -based

Only one of the two VLAN types can be enabled at one time.

Port-based VLANs are VLANs where the packet forwarding decision is made based on the destination MAC address and its associated port. You must define the outgoing ports allowed for each port when you use port-based VLANs. In port-based VLANs, the packets received from one port can only be sent to the ports which are configured to the same VLAN. As shown in the following figure, the switch administrator configured port 1-2 as VLAN 1 and port 3-4 as VLAN 2. The packets received from port 1 can only be forwarded to port 2. The packets received from port

show lacp port

Page 160 of the GE 82-POE user manual — VLAN Mode: Port-based
Page 160 · click to enlarge
Page 160
Chapter 6Command Line Interface

2 can only be forwarded to port 1. That means the computer A can send packets to computer B, and vice versa. The same situation also occurred in VLAN 2. The computer C and D can communicate with each other. However, the computers in VLAN 1 can not see the computers in VLAN 2 since they belonged to different VLANs.

IEEE 802.1Q (tag) -based VLANs enable the Ethernet functionality to propagate tagged packets across the bridges and provides a uniform way for creating VLAN within a network then span across the network. For egress packet, you can choose to tag it or not with the associated VLAN ID of this port. For ingress packet, you can forward this packet to a specific port as long as it is also in the same VLAN group.

The 802.1Q VLAN works by using a tag added to the Ethernet packets. The tag contains a VLAN Identifier (VID) which belongs to a specific VLAN group. And ports can belong to more than one VLAN.

The difference between a port-based VLAN and a tag-based VLAN is that the tag- based VLAN truly divided the network into several logically connected LANs. Packets rambling around the switches can be forwarded more intelligently. In the figure shown below, by identifying the tag, broadcast packets coming from computer A in VLAN1 at sw1 can be forwarded directly to VLAN1.

However, the switch could not be so smart in the port-based VLAN mechanism. Broadcast packets will also be forwarded to port 4 of sw2. It means the port-based VLAN can not operate a logical VLAN group among switches.

The GE-DS-82-PoEsupports both Port-based VLAN and Tag-based (802.1Q) VLAN modes. The default configuration is tag-based (802.1Q) VLAN. In the 802.1Q VLAN, initially, all ports on the switch belong to default VLAN, VID is 1.

VLAN Mode: Port-based

Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored.

Description:

Display the current VLAN mode.

show vlan mode

Page 161 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 161 · click to enlarge
Page 161
Chapter 6Command Line Interface

Description:

Change VLAN mode.

Syntax:

Parameters:

(disabled | port-based | dot1q) specifies the VLAN mode.

Advanced 802.1Q VLAN Configuration

When a packet was received on a port, you can govern the switch to drop it or not if it is an untagged packet. Furthermore, if the received packet is tagged but not belonging to the same VALN group of the receiving port, you can also control the switch to forward or drop the packet. The example below configures the switch to drop the packets not belonging to the same VLAN group and forward the packets not containing VLAN tags.

Description:

Display the current VLAN mode.

Description:

Change VLAN mode.

Syntax:

Parameters:

(disabled | port-based | dot1q) specifies the VLAN mode.

Show 6 more labels / short text on this page
vlan mode · vlan mode (disabled|port-based|dot1q) · Ingress filters configuration · show vlan mode · vlan mode · vlan mode (disabled|port-based|dot1q)
Page 162 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 162 · click to enlarge
Page 162
Chapter 6Command Line Interface

Description:

Add or edit VLAN entry.

Syntax:

vlan add <1-4094> NAME (cpu-port|no-cpu-port) LIST [LIST]

Parameters:

<1-4094> specifies the VLAN id or Group id (if port based VLAN mode)

NAME specifies the VLAN group name.

(cpu-port|no-cpu-port) specifies the CPU port belong this VLAN group.

LIST specifies the ports to be set to VLAN members.

[LIST] specifies the ports to be set to tagged members. If not entered, all members set to untagged.

e.g.. switch(config)# vlan add 1 vlan1 cpu-port 1-4

This VLAN entry has four members (from port1 to port4) and all members are untagged.

Description:

Delete VLAN entry.

Syntax:

Parameters:

<1-4094> specifies the VLAN id or group id (if port based VLAN).

e.g. no vlan 1

vlan mode · no vlan · no vlan <1-4094>

Page 163 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 163 · click to enlarge
Page 163
Chapter 6Command Line Interface

Description:

Show VLAN entry information.

Syntax:

Parameters:

specifies the VLAN id, null means all valid entries.

e.g.

show vlan · show vlan [<1-4094>]

Page 164 of the GE 82-POE user manual — VLAN : 1
Page 164 · click to enlarge
Page 164
Chapter 6Command Line Interface

Switch(config)# show vlan 1

VLAN : 1

TypeStatic
Creation Time (sec.)43
CPU PortYes
Show 28 more labels / short text on this page
Port | Member · -----------+-------------- · Port1 | Untagged · Port2 | Untagged · Port3 | Untagged · Port4 | Untagged · Port5 | Untagged · Port6 | Untagged · Port7 | Untagged · Port8 | Untagged · Port9 | Untagged · Port10 | Untagged · Port11 | Untagged · Port12 | Untagged · Port13 | Untagged · Port14 | Untagged · Port15 | Untagged · Port16 | Untagged · --More-- · Port17 | Untagged · Port18 | Untagged · Port19 | Untagged · Port20 | Untagged · Port21 | Untagged · Port22 | Untagged · Port25 | Untagged · Port26 | Untagged · Trk1 | Untagged
Page 165 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 165 · click to enlarge
Page 165
Chapter 6Command Line Interface

Description:

Show static VLAN entry information.

Description:

Show port default VLAN id.

Syntax:

show vlan pvid [LIST]

Parameters:

[LIST] specifies the ports to be showed. If not entered, all port’s PVID will be showed.

e.g.

show vlan static · show vlan pvid

Page 166 of the GE 82-POE user manual — Table of contents
Page 166 · click to enlarge
Page 166

Table of contents

Package Contentsp.6Product Descriptionp.6High Performance Wire-Speed Switchingp.6Cost-effective solution with SNMP monitor for Network deploymentp.7Remote and Centralize Management installationp.7Powerful Securityp.7Power over Ethernet of GE-DS-82-PoEp.8How to Use this Manualp.8Product Featuresp.8Physical Portp.8Product Specificationsp.11Hardware Descriptionp.15Switch Front Panelp.15LED Indicationsp.16Switch Rear Panelp.18Switch Installationp.20Desktop/Shelf Installationp.20Rack-mount Installationp.21SFP Transceiver Installationp.22Summaryp.27Requirementsp.27Management Access Overviewp.28Web Browser Managementp.29Web Browser Setupp.30SNMP-Based Network Managementp.32The Administration Consolep.32Direct Accessp.33Protocolsp.34Virtual Terminal Protocolsp.34Telnet Setupp.34SNMP Protocolp.36Management Architecturep.36About Web-based Managementp.37Requirementsp.38Logging on to the Switchp.39Main Web Pagep.40Panel Displayp.40Main Menup.41Systemp.42System Informationp.42IP Configurationp.45SNMP Configurationp.47SNMPv3 Viewp.52Firmware Upgradep.55Configuration Backupp.57Factory Defaultp.59Syslog Settingp.60Port Configurationp.60Port Statusp.63Port Statisticsp.63Port Snifferp.65Protected Portp.67VLAN Configurationp.68VLAN Overviewp.68Static VLAN Configurationp.71Port-Based VLANp.72802.1Q VLANp.75802.1Q VLANp.80GVRP VLANp.84GVRP Settingp.84Rapid Spanning Treep.87Theoryp.87Illustration of STPp.90STP Parametersp.92RSTP System Configurationp.93Port Configurationp.96Trunkingp.98Aggregator Settingp.99Aggregator Informationp.100State Activityp.104Forwarding and Filteringp.105Dynamic MAC Tablep.105Static MAC Tablep.106MAC Filteringp.107IGMP Snoopingp.109Theoryp.109IGMP Configurationp.113QoS Configurationp.114Understand QOSp.114QoS Configurationp.115TOS/DSCPp.117Access Control Listp.120MAC Limitp.125MAC Limit Configurationp.125MAC Limit Port Statusp.126802.1X Configurationp.127Understanding IEEE 802.1X Port-Based Authenticationp.127System Configurationp.131802.1x Port Configurationp.132Misc Configurationp.134Power Over Ethernetp.135Power over Ethernet Powered Devicep.135Power Managementp.135DHCP Relay and Option 82p.139LLDPp.140Login in to the Console Interfacep.143Configure IP addressp.145Commands Levelp.147Operation Noticep.149Command Line Editingp.150Command Helpp.150System Commandsp.150Switch Static Configurationp.151Port Configuration and show statusp.151Trunk Configurationp.155Trunking Commandsp.155LACP Commandsp.157VLAN Configurationp.159Virtual LANsp.159VLAN Mode: Port-basedp.160Advanced 802.1Q VLAN Configurationp.161Misc Configurationp.169Administration Configurationp.171Change Username / Passwordp.171IP Configurationp.172Reboot switchp.173Reset to Defaultp.173TFTP Update Firmwarep.174Restore Configure Filep.174Backup Configure Filep.175MAC limitp.176Port Mirroring Configurationp.177Quality of Servicep.178QoS Configurationp.178Per Port Priorityp.180MAC Address Configurationp.181STP/RSTP Commandsp.183SNMPp.188System Optionsp.188Community Stringsp.190Trap Managersp.191IGMPp.192802.1x Protocolp.194Access Control Listp.198Ipv4 ACL commandsp.198Non-Ipv4 ACL commandsp.201Bindingp.203SIP/SMAC binding commandsp.203Power over Ethernet Commands (GE DS-82-PoE)p.205Display System PoE statusp.205Configure PoE Over Temperature Protectionp.207Configure PoE - Systemp.207Configure PoE -- Portp.209Address Tablep.213Learningp.213Forwarding & Filteringp.213Store-and-Forwardp.214Auto-Negotiationp.214What is PoE?p.215PoE System Architecturep.216How Power is Transferred Through the Cablep.216The PoE Provision Processp.218Stages of powering up a PoE linkp.218Line Detectionp.219Classificationp.219Start-upp.219Operationp.219Power Overloadsp.220Power Disconnection Scenariosp.220DC Disconnectp.220AC Disconnectp.220Switch's RJ-45 Pin Assignmentsp.22310/100Mbps, 10/100Base-TXp.224
Page 167 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 167 · click to enlarge
Page 167
Chapter 6Command Line Interface

Description:

Set ingress filter rules.

Syntax:

vlan filter (enable | disable) (enable | disable) LIST

Parameters:

(enable | disable) specifies the non-members packet will be forwarded or not. If set enable, forward only packets with VID matching this port's configured VID.

(enable | disable) specifies the untagged frame will be dropped or not. If set enable, drop untagged frame.

Description:

Show VLAN filter setting.

Syntax:

show vlan filter [LIST]

Parameters:

[LIST] specifies the ports to be showed. If not entered, all ports’ filter rules will be shown.

vlan filter · show vlan filter

Page 168 of the GE 82-POE user manual — Advanced 802.1Q VLAN Configuration
Page 168 · click to enlarge
Page 168
Chapter 6Command Line Interface

Switch(config)# show vlan filter

Port | Rule 1 | Rule 2

Port1 | Drop | Forward

Port2 | Drop | Forward

Port3 | Drop | Forward

Port4 | Drop | Forward

Port5 | Drop | Forward

Port6 | Drop | Forward

Port7 | Drop | Forward

Port8 | Drop | Forward

Port9 | Drop | Forward

Port10 | Drop | Forward

Port11 | Drop | Forward

Port12 | Drop | Forward

Port13 | Drop | Forward

Port14 | Drop | Forward

Port15 | Drop | Forward

Port16 | Drop | Forward

Port17 | Drop | Forward

Port18 | Drop | Forward

Port19 | Drop | Forward

Port20 | Drop | Forward

Port21 | Drop | Forward

Port22 | Drop | Forward

Port25 | Drop | Forward

Port26 | Drop | Forward

Trk1 | Drop | Forward

Filter (nonmbr) (untag) · + + · --More--

Page 169 of the GE 82-POE user manual — Misc Configuration
Page 169 · click to enlarge
Page 169
Chapter 6Command Line Interface

Misc Configuration

Description:

Set MAC address age-out time.

Syntax:

[no] mac-age-time Enable or disable MAC address age-out.

mac-age-time

Parameters:

specifies the MAC address age-out time. Must be divisible by 6. Type the number of seconds that an inactive MAC address remains in the switch’s address table.

Description:

Show MAC address age-out time.

Description:

Set broadcast storm filter mode to off, 1/2, 1/4, 1/8, 1/16

Syntax:

broadcast mode

no mac-age-time · show mac-age-time · broadcast

Page 170 of the GE 82-POE user manual — Misc Configuration
Page 170 · click to enlarge
Page 170
Chapter 6Command Line Interface

Description:

Select the Broadcast storm filter packet type:

Unicast/MulticastFlood unicast/multicast filter
Control PacketsControl packets filter
IP multicastIP multicast packets filter
Broadcast PacketsBroadcast Packets filter

Syntax:

broadcast select

Description:

Syntax:

Collision-Retry < off | 16 | 32 | 48 >

Parameters:

16\32\48 – In Half-Duplex, collision-retry maximum is 16\32\48 times and packet will be dropped if collisions still happen

Disable – In Half-Duplex, if collision occurs, will retry forever (Default).

broadcast select · Collision-Retry · Collision-Retry setting

Page 171 of the GE 82-POE user manual — Change Username / Password
Page 171 · click to enlarge
Page 171
Chapter 6Command Line Interface

Administration Configuration

Change Username / Password

Description:

Set switch name.

Syntax:

hostname

Parameters:

specifies the switch name. If you would like to have spaces within the name, use quotes (“”) around the name.

Reset the switch name to factory default setting.

Description:

Set or remove username and password for manager or operator.

Syntax:

[no] password

Parameters:

The manager username and password is also used by the web UI.

hostname · no hostname · [no] password

Page 172 of the GE 82-POE user manual — IP Configuration
Page 172 · click to enlarge
Page 172
Chapter 6Command Line Interface

IP Configuration

User can configure the IP setting and fill in the new value.

Description:

Set IP address and subnet mask.

Syntax:

ip address

Description:

Set the default gateway IP address.

Syntax:

ip default-gateway

Description:

Show IP address, subnet mask, and the default gateway.

Description:

Show basic information, including system info, MAC address, and versions.

Model nameGE-DS-242-PoE
Description24-Port 10/100Mbps + 2G TP/SFP Combo Managed Switch
MAC address00:30:4F:44:55:66
Firmware version2.08
CLI version1.07
802.1xdisabled
IGMPenabled
LACPenabled
Show 5 more labels / short text on this page
ip address · ip default-gateway · show ip · show info · Switch(config)# show info
Page 173 of the GE 82-POE user manual — Reset to Default
Page 173 · click to enlarge
Page 173
Chapter 6Command Line Interface

Description:

Set switch as dhcp client, it can get ip from dhcp server.

Description:

Show dhcp enable/disable.

Reboot switch

Description:

Reboot (warm-start) the switch.

Reset to Default

Description:

Reset configurations to default factory settings at next boot time.

Show 4 more labels / short text on this page
dhcp · show dhcp · boot · erase startup-config
Page 174 of the GE 82-POE user manual — Restore Configure File
Page 174 · click to enlarge
Page 174
Chapter 6Command Line Interface

TFTP Update Firmware

Description:

Download firmware from TFTP server.

Syntax:

copy tftp firmware

Parameters:

specifies the IP address of the TFTP server.

specifies the file to be downloaded from the TFTP server.

Restore Configure File

copy tftp <running – config | flash>

Description:

Retrieve configuration from the TFTP server. If the remote file is the text file of CLI commands, use the keyword running-config.

If the remote file is the configuration flash image of the switch instead, use the keyword flash.

Syntax:

copy tftp

Parameters:

specifies the IP address of the TFTP server.

specifies the file to be downloaded from the TFTP server.

copy tftp firmware

Page 175 of the GE 82-POE user manual — Backup Configure File
Page 175 · click to enlarge
Page 175
Chapter 6Command Line Interface

Backup Configure File

copy <running – config | flash> tftp

Description:

Send configuration to the TFTP server. If you want to save the configuration in a text file of CLI commands, use the keywordrunning-config. If you want to save the configuration flash image instead, use the keyword flash.

Syntax:

copy tftp

Parameters:

specifies the IP address of the TFTP server.

Page 176 of the GE 82-POE user manual — MAC limit
Page 176 · click to enlarge
Page 176
Chapter 6Command Line Interface

MAC limit

MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table is the result of first-come-first-save policy. Once a MAC address is stored in the MAC address table, it stays in until it is aged out. When an “opening” is available, the switch stored the first new MAC address it sees in that opening. All packets from MAC addresses not in the MAC address table should be blocked.

User can configure the MAC limit setting and fill in the new value.

Description:

Enable MAC limit.

Description:

Disable MAC limit.

Description:

Set port MAC limit value, 0 to turn off MAC limit of port.

Syntax:

Description:

Show MAC limit information, including MAC limit enable/disable, per-port MAC limit setting.

Show 5 more labels / short text on this page
mac-limit · no mac-limit · Mac-limit · Mac-limit <port-list> <1-64> · show mac-limit
Page 177 of the GE 82-POE user manual — Port Mirroring Configuration
Page 177 · click to enlarge
Page 177
Chapter 6Command Line Interface

Port Mirroring Configuration

Port monitoring is a feature to redirect the traffic occurred on every port to a designated monitoring port on the switch. With this feature, the network administrator can monitor and analyze the traffic on the entire LAN segment. In the Managed Switch, you can specify one port to be the monitored ports and any single port to be the monitoring port. You also can specify the direction of the traffic that you want to monitor. After properly configured, packets with the specified direction from the monitored ports are forwarded to the monitoring port.

Description:

Set port monitoring information. (RX only|TX only|both RX and TX)

Syntax:

mirror-port

Parameters:

rx specifies monitoring rx only.

tx specifies monitoring tx only.

both specifies monitoring both rx and tx.

specifies the analysis port ID. This port receives traffic from all monitored ports.

specifies the monitored port list.

Description:

Show port monitoring information.

mirror-port · show mirror-port

Page 178 of the GE 82-POE user manual — QoS Configuration
Page 178 · click to enlarge
Page 178
Chapter 6Command Line Interface

Quality of Service

There are four transmission queues with different priorities in the Managed Switch: Highest, SecHigh, SecLow and Lowest. The Managed Switch will take packets from the four queues according to its QoS mode setting. If the QoS mode was set to "Disable", the Managed Switch will not perform QoS on its switched network. If the QoS mode was set to "High Empty Then Low", the Managed Switch will never exhaust packets from a queue until the queues with higher priorities are empty. If the QoS mode was set to "weight ratio", the Managed Switch will exhaust packets from the queues according to the ratio. The default value of QoS mode is "weight 8:4:2:1." That means the switch will first exhaust 8 packets from the queue with highest priority, and then exhaust 4 packets from the queue with second high priority, and so on.

When the switch received a packet, the switch has to decide which queue to put the received packet into. In the Managed Switch, it will put received packets into queues according to the settings of "802.1p Priority" and "Static Port Ingress Priority." When the received packet is an 802.1p tagged packet, the switch will put the packet into a queue according to the 802.1p Priority setting.

Otherwise, the switch will put the packet into a queue according the setting of Static Port Ingress Priority.

  • 802.1p Priority: the 802.1p packet has a priority tag in its packet header. The range of the priority is 7-0. The Managed Switch can specify the mapping between 802.1p priority and the four transmission queues. In the default setting, the packets with 802.1p priority 0-1 are put into the queue with lowest priority, the packets with 802.1p priority 2-3 are put into queue with second low priority, and so on.
  • Static Port Ingress Priority: each port is assigned with one priority 7-0. The priority of the packet received from one port is set to the same priority of the receiving port. When the priority of the received packet was determined, the packet is treated as an 802.1p packet with that priority and will be put into a queue according to the 802.1p Priority setting.

QoS Configuration

QoS mode:

  • First Come First Service: The sequence of packets sent is depending on arrive orders.
  • All High before Low: The high priority packets sent before low priority packets.
  • WRR: Weighted Round Robin. Select the preference given to packets in the switch's high-priority queue. These options represent the number of higher
Page 179 of the GE 82-POE user manual — Quality of Service
Page 179 · click to enlarge
Page 179
Chapter 6Command Line Interface

priority packets sent before one lower priority packet is sent. For example, 8 Highest:4 second-high means that the switch sends 8 highest-priority packets before sending 4 second-high priority packets.

  • QoS level: 0-7 priority level can map to highest, second-high, second-low, lowest queue.

Description:

Set 802.1p priority.

Syntax:

qos priority <first-come-first-service | all-high-before-low |weighted-round-robin>

Parameters:

[][][] []

e.g. qos priority weighted-round-robin 8,4,2,1.

Description:

Set priority levels to highest, second-high, second-low and lowest.

Syntax:

qos level < highest | second-high | second-low | lowest >

Parameters:

specifies the priority levels to be high or low.

between 1 and 7.

e.g. qos level highest 7

e.g. qos level lowest 4

qos priority · qos level · Level must be

Page 180 of the GE 82-POE user manual — Per Port Priority
Page 180 · click to enlarge
Page 180
Chapter 6Command Line Interface

Description:

Show QoS configurations, including802.1p priority, priority level.

e.g.

QoS configurations:

QoS modeweighted round robin
Highest weight8
Second High weight4
Second Low weight2
Lowest weight1

802.1p priority[0-7]:

Lowest Lowest SecLow SecLow SecHigh SecHigh Highest Highest

Per Port Priority

Description:

Set port priority.

Syntax:

port priority <disable | [0-7]> []

Parameters:

specifies the ports to be set. If not entered, all ports are set.

e.g. port priority disable 1-5

show qos · Switch(config)# show qos · port priority

Page 181 of the GE 82-POE user manual — MAC Address Configuration
Page 181 · click to enlarge
Page 181
Chapter 6Command Line Interface

MAC Address Configuration

Description:

Clear all dynamic MAC address table entries.

Description:

Set static unicast or multicast MAC address. If multicast MAC address (address beginning with 01:00:5E) is supplied, the last parameter must be port-list. Otherwise, it must be port-id.

Syntax:

mac-address-table static

no mac-address-table static mac-addr

Description:

Delete static unicast or multicast MAC address table entries.

Syntax:

no mac-address-table static mac-addr

Description:

Display MAC address table entries.

MAC Address | VLAN | Type | Source

00:08:B6:00:06:90 | 1 | Dynamic | 25

00:40:63:00:65:30 | 1 | Dynamic | Trk1

00:03:63:F7:80:7F | 1 | Dynamic | 25

Show 5 more labels / short text on this page
clear mac-address-table · mac-address-table static · show mac-address-table · Switch(config)# show mac-address-table · ------------------------------+--------+--------------+------------------------------
Page 182 of the GE 82-POE user manual — MAC Address Configuration
Page 182 · click to enlarge
Page 182
Chapter 6Command Line Interface

Description:

Display static MAC address table entries.

Description:

Display multicast-related MAC address table.

Description:

Set static unicast or multicast MAC address in secondary MAC address table. If multicast MAC address (address beginning with 01:00:5E) is supplied, the last parameter must be port-list. Otherwise, it must be port-id.

Syntax:

smac-address-table static

Description:

Display secondary MAC address table entries.

Description:

Display multicast-related secondary MAC address table.

Description:

Set MAC address filter. The packets will be filtered if both of the destination MAC address and the VLAN tag matches the filter entry. If the packet does not have a VLAN tag, then it matches an entry with VLAN ID 1.

Syntax:

[no] filter <mac-addr> <vlan-id>

Show 6 more labels / short text on this page
show mac-address-table static · show mac-address-table multicast · smac-address-table static · show smac-address-table · show smac-address-table multicast · [no] filter
Page 183 of the GE 82-POE user manual — STP/RSTP Commands
Page 183 · click to enlarge
Page 183
Chapter 6Command Line Interface

Description:

Display filter MAC address table.

STP/RSTP Commands

Description:

Enable or disable spanning-tree.

Description:

Set spanning tree forward delay used, in seconds.

Syntax:

spanning-tree forward-delay <4-30>

Parameters:

specifies the forward delay, in seconds. Default value is 15.

Description:

Set spanning tree hello time, in seconds.

Syntax:

Parameters:

specifies the hello time, in seconds. Default value is 2.

2*(hello-time + 1)

Show 5 more labels / short text on this page
show filter · [no] spanning-tree · spanning-tree forward-delay · spanning-tree hello-time · spanning-tree hello-time <1-10>
Page 184 of the GE 82-POE user manual — STP/RSTP Commands
Page 184 · click to enlarge
Page 184
Chapter 6Command Line Interface

Description:

Set spanning tree maximum age, in seconds.

Syntax:

Parameters:

specifies the maximum age, in seconds. Default value is 20.

2*(hello-time + 1)

Description:

Set spanning tree bridge priority.

Syntax:

Parameters:

specifies the bridge priority. The value must be in steps of 4096.

Description:

Set spanning tree port path cost.

Syntax:

spanning-tree port path-cost <1-200000000> [<port-list>]

Parameters:

specifies port path cost.

specifies the ports to be set. Null means all ports.

Show 6 more labels / short text on this page
spanning-tree maximum-age · spanning-tree maximum-age <6-40> · spanning-tree priority · spanning-tree priority <0-61440> · spanning-tree port path-cost · spanning-tree port priority
Page 185 of the GE 82-POE user manual — STP/RSTP Commands
Page 185 · click to enlarge
Page 185
Chapter 6Command Line Interface

Description:

Set spanning tree port priority.

Syntax:

spanning-tree port priority <0-240> [<port-list>]

Parameters:

specifies the port priority. The value must be in steps of 16.

specifies the ports to be set. Null means all ports.

Description:

Show spanning-tree information.

Description:

Show spanning tree per port information.

Syntax:

show spanning-tree port [<port-list>]

Parameters:

specifies the port to be shown. Null means all ports.

The remaining commands in this section are only for system with RSTP (rapid spanning tree, 802.1w) capability:

Description:

Enable or disable spanning tree debugging information.

show spanning-tree · show spanning-tree port · spanning-tree debug

Page 186 of the GE 82-POE user manual — STP/RSTP Commands
Page 186 · click to enlarge
Page 186
Chapter 6Command Line Interface

Description:

Change spanning tree protocol version.

Syntax:

spanning-tree protocol-version <stp | rstp>

Parameters:

stp specifies the original spanning tree protocol (STP,802.1d).

rstp specifies rapid spanning tree protocol (RSTP,802.1w).

[no] spanning-tree port mcheck

Description:

Force the port to transmit RST BPDUs.

No format means not force the port to transmit RST BPDUs.

Syntax:

[no] spanning-tree port mcheck [<port-list>]

Parameters:

specifies the ports to be set. Null means all ports.

[no] spanning-tree port edge-port

Description:

Set the port to be edge connection. No format means set the port to be non-edge connection.

Syntax:

[no] spanning-tree port edge-port [<port-list>]

Parameters:

specifies the ports to be set. Null means all ports.

spanning-tree protocol version

Page 187 of the GE 82-POE user manual — STP/RSTP Commands
Page 187 · click to enlarge
Page 187
Chapter 6Command Line Interface

[no] spanning-tree port non-stp

Description:

Disable or enable spanning tree protocol on this port.

Syntax:

[no] spanning-tree port non-stp [<port-list>]

Parameters:

specifies the ports to be set. Null means all ports.

Description:

Set the port to be point to point connection.

Syntax:

spanning-tree port point-to-point-mac <auto | true | false> [<port-list>]

Parameters:

auto specifies point to point link auto connection.

true specifies point to point link true.

false specifies point to point link false.

specifies the ports to be set. Null means all ports.

Description:

Show spanning-tree information of CIST.

Description:

Show spanning tree port information of CIST.

Syntax:

show spanning-tree port [<port-list>]

Parameters:

specifies the port to be shown. Null means all ports.

spanning-tree point-to-point mac · show spanning-tree · show spanning-tree port

Page 188 of the GE 82-POE user manual — System Options
Page 188 · click to enlarge
Page 188
Chapter 6Command Line Interface

SNMP

Any Network Management system running the simple Network Management Protocol (SNMP) can be managed by the switch.

System Options

Description:

Enable or disable SNMP.

Description:

Show the enable or disable status of SNMP.

Description:

Set agent system name string.

Syntax:

Parameters:

specifies the system name string.

e.g. snmp system-name SWITCH

Show 4 more labels / short text on this page
Snmp /no snmp · Show snmp status · Snmp system-name · snmp system-name <name-str>
Page 189 of the GE 82-POE user manual — SNMP
Page 189 · click to enlarge
Page 189
Chapter 6Command Line Interface

Description:

Set agent location string.

Syntax:

Parameters:

specifies the location string.

e.g. snmp system-location office

Description:

Set agent system contact string.

Syntax:

Parameters:

specifies the contact string.

e.g. snmp system-contact abc@sina.com

Description:

Show SNMP system information.

Show 5 more labels / short text on this page
Snmp system-location · snmp system-location <location-str> · Snmp system-contact · snmp system-contact <contact-str> · show snmp system
Page 190 of the GE 82-POE user manual — Community Strings
Page 190 · click to enlarge
Page 190
Chapter 6Command Line Interface

Community Strings

Description:

Set SNMP community string.

Syntax:

snmp community <read-sysinfo-only | read-all-only | read-write-all><community- str>

Parameters:

specifies the community string.

e.g. snmp community read-all-only public

Description:

Delete SNMP community string.

Syntax:

no snmp community <community-str>

Parameters:

specifies the community string.

e.g. no snmp community public

Description:

Show SNMP community strings.

snmp community · no snmp community · show snmp community

Page 191 of the GE 82-POE user manual — Trap Managers
Page 191 · click to enlarge
Page 191
Chapter 6Command Line Interface

Trap Managers

Description:

Set SNMP trap receiver IP address, community string, and port number.

Syntax:

snmp trap <ip-addr> [<community-str>] [<1..65535>]

Parameters:

specifies the IP address.

specifies the community string.

specifies the trap receiver port number.

e.g. snmp trap 192.168.200.1 public

Description:

Remove trap receiver IP address and port number.

Syntax:

no snmp trap <ip-addr> [<1..65535>]

Parameters:

specifies the IP address.

specifies the trap receiver port number.

e.g. no snmp trap 192.168.200.1

Description:

Show all trap receivers.

snmp trap · no snmp trap · show snmp trap

Page 192 of the GE 82-POE user manual — IGMP
Page 192 · click to enlarge
Page 192
Chapter 6Command Line Interface

IGMP

The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite.

Description:

Enable/disable IGMP snooping.

Syntax:

Description:

Enable/disable IGMP snooping fast leave. If enable, switch will fast delete member who send leave report, else wait one sec.

Syntax:

Description:

Enable/disable IGMP snooping querier.

Syntax:

Description:

Enable/disable IGMP snooping CrossVLAN

Syntax:

Show 8 more labels / short text on this page
igmp · [no] igmp · igmp fastleave · [no] igmp fastleave · igmp querier · [no] igmp querier · igmp crossVLAN · [no] igmp CrossVLAN
Page 193 of the GE 82-POE user manual — IGMP
Page 193 · click to enlarge
Page 193
Chapter 6Command Line Interface

Description:

Enable/disable IGMP snooping debugging output.

Syntax:

Description:

Show IGMP snooping information.

Syntax:

show igmp <status | router | groups | table>

Parameters:

status specifies IGMP snooping status and statistics information.

router specifies IGMP snooping router's IP address.

groups specifies IGMP snooping multicast group list.

table specifies IGMP snooping IP multicast table entries.

Description:

Clear IGMP snooping statistics counters.

Show 4 more labels / short text on this page
igmp debug · [no] igmp debug · show igmp · igmp clear_statistics
Page 194 of the GE 82-POE user manual — 802.1x Protocol
Page 194 · click to enlarge
Page 194
Chapter 6Command Line Interface

802.1x Protocol

Description:

Enable or disable 802.1x.

Syntax:

Description:

Set radius server IP, port number, and accounting port number.

Syntax:

radius-server host <ip-addr> <1024..65535> <1024..65535>

Parameters:

specifies server's IP address.

The first specifies the server port number.

The second specifies the accounting port number.

Description:

Set 802.1x shared key.

Syntax:

Parameters:

specifies shared key string.

Show 5 more labels / short text on this page
dot1x · [no] dot1x · radius-server host · radius-server key · radius-server key <key-str>
Page 195 of the GE 82-POE user manual — 802.1x Protocol
Page 195 · click to enlarge
Page 195
Chapter 6Command Line Interface

Description:

Set 802.1x NAS identifier.

Syntax:

Parameters:

specifies NAS identifier string.

Description:

Show radius server information, including radius server IP, port number, accounting port number, shared key, NAS identifier,

Description:

Set 802.1x quiet period. (default60 seconds)

Syntax:

dot1x timeout quiet-period <0..65535>

Parameters:

specifies the quiet period, in seconds.

Description:

Set 802.1x Tx period. (default: 15 seconds).

Syntax:

dot1x timeout tx-period <0..65535>

Parameters:

specifies the Tx period, in seconds.

Show 5 more labels / short text on this page
radius-server nas · radius-server nas <id-str> · show radius-server · dot1x timeout quiet-period · dot1x timeout tx-period
Page 196 of the GE 82-POE user manual — 802.1x Protocol
Page 196 · click to enlarge
Page 196
Chapter 6Command Line Interface

Description:

Set 802.1x supplicant timeout (default30 seconds)

Syntax:

dot1x timeout supplicant <1..300>

Parameters:

specifies the supplicant timeout, in seconds.

Description:

Set radius server timeout (default: 30 seconds).

Syntax:

dot1x timeout radius-server <1..300>

Parameters:

specifies the radius server timeout, in seconds.

Description:

Set 802.1x maximum request retries (default: 2 times).

Syntax:

dot1x max-req <1..10>

Parameters:

specifies the maximum request retries.

Description:

Set 802.1x re-auth period (default: 3600 seconds).

Syntax:

dot1x timeout re-authperiod <30..65535>

Parameters:

specifies the re-auth period, in seconds.

Show 4 more labels / short text on this page
dot1x timeout supplicant · dot1x timeout radius-server · dot1x max-req · dot1x timeout re-authperiod
Page 197 of the GE 82-POE user manual — 802.1x Protocol
Page 197 · click to enlarge
Page 197
Chapter 6Command Line Interface

Description:

Show 802.1x information, quiet period, Tx period, supplicant timeout, server timeout, maximum requests, and re-auth period.

Description:

Set 802.1x per port information.

Syntax:

dot1x port <fu | fa | au | no> <port-list>

Parameters:

fu specifies forced unauthorized.

fa specifies forced authorized.

au specifies authorization.

no specifies disable authorization.

specifies the ports to be set.

Description:

Show 802.1x per port information.

show dot1x · dot1x port · show dot1x port

Page 198 of the GE 82-POE user manual — Ipv4 ACL commands
Page 198 · click to enlarge
Page 198
Chapter 6Command Line Interface

Access Control List

Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be used to block packets by maintaining a table of packet fragments indexed by source and destination IP address, protocol, and so on.

Ipv4 ACL commands

Description:

Delete ACL group.

Syntax:

Parameters:

specifies the group id.

e.g. no acl 1

Description:

Reset the ACL group count.

Syntax:

no acl count <GroupId>

Parameters:

GroupId: specifies the group id.

no acl · no acl <1-220> · no acl count

Page 199 of the GE 82-POE user manual — Access Control List
Page 199 · click to enlarge
Page 199
Chapter 6Command Line Interface

Description:

Show ACL group information.

Syntax:

Parameters:

specifies the group id, null means all valid groups.

e.g.

Switch(config)# show acl 1

Group Id1

Switch(config)# show acl 1

Group Id1
ActionPermit

Rules:

Vlan IDAny
IP FragementUncheck
Src IP AddressAny
Dst IP AddressAny
L4 ProtocolAny
Port IDAny
Hit Octet Count165074
Hit Packet count472

show acl · show acl [<1-220>] ·

Page 200 of the GE 82-POE user manual — Access Control List
Page 200 · click to enlarge
Page 200
Chapter 6Command Line Interface

acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255>

Description:

Add or edit ACL group for Ipv4.

Syntax:

acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255> A.B.C.D (check|unCheck) <0-65535> <0-26>

Parameters:

(add|edit) specifies the operation.

<1-220> specifies the group id.

(permit|deny) specifies the action. permit: permit packet cross switch; deny: drop packet.

<0-4094> specifies the VLAN id. 0 means don't care.

<0-255> specifies the IP protocol. 0 means don't care.

A.B.C.D specifies the Source IP address. 0.0.0.0 means don't care.

A.B.C.D specifies the Mask. 0.0.0.0 means don't care, 255.255.255.255 means compare all.

A.B.C.D specifies the Destination IP Address. 0.0.0.0 means don't care.

A.B.C.D specifies the Mask. 0.0.0.0 means don't care, 255.255.255.255 means compare all.

(check|unCheck) specifies the IP Fragment. check: Check IP fragment field; unCheck: Not check IP fragment field.

<0-65535> specifies the Destination port number if TCP or UDP. 0 means don't care.

<0-26> specifies the Port id. 0 means don't care.

e.g.

Switch(config)# acl add 1 deny 1 ipv4 0 192.168.1.1 255.255.255.255 0.0.0.0 0.0.0.0 unCheck 0 0

This ACL rule will drop all packet from IP is 192.168.1.1 with VLAN id=1 and IPv4.

Page 201 of the GE 82-POE user manual — Non-Ipv4 ACL commands
Page 201 · click to enlarge
Page 201
Chapter 6Command Line Interface

acl (add|edit) <1-220> (qosvoip) <0-4094>

Description:

Add or edit ACL group for Ipv4.

Syntax:

acl (add|edit) <1-220> (qosvoip) <0-4094> <0-7> <0-1F> <0-1F> <0-FF> <0-FF> <0- FFFF> <0-FFFF> <0-FFFF> <0-FFFF>

Parameters:

(add|edit) specifies the operation.

<1-220> specifies the group id.

(qosvoip) specifies the action, do qos voip packet adjustment.

<0-4094> specifies the VLAN id. 0 means don't care.

<0-1F> specifies the port ID value.

<0-1F> specifies the port ID mask.

<0-FF> specifies the protocol value.

<0-FF> specifies the protocol mask.

<0-FFFF> specifies the source port value.

<0-FFFF> specifies the source port mask.

<0-FFFF> specifies the destination port value.

<0-FFFF> specifies the destination mask.

e.g. acl add 1 qosvoip 1 7 1 1 0

Non-Ipv4 ACL commands

no acl <1-220> and show acl [<1-220>] commands are same as Ipv4 ACL commands.

Page 202 of the GE 82-POE user manual — Non-Ipv4 ACL commands
Page 202 · click to enlarge
Page 202
Chapter 6Command Line Interface

acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-65535>

Description:

Add or edit ACL group for non-Ipv4.

Syntax:

acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-65535>

Parameters:

(add|edit) specifies the operation.

<1-220> specifies the group id.

(permit|deny) specifies the action. permit: permit packet cross switch; deny: drop packet.

<0-4094> specifies the VLAN id. 0 means don't care.

<0-65535> specifies the Ether Type. 0 means don't care.

e.g. acl add 1 deny 0 nonipv4 2054. This ACL rule will drop all packets for either type is 0x0806 and non-IPv4.

Page 203 of the GE 82-POE user manual — SIP/SMAC binding commands
Page 203 · click to enlarge
Page 203
Chapter 6Command Line Interface

Binding

Let device that has specific IP address and MAC address can use network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match.

SIP/SMAC binding commands

Description:

Enable binding function.

Description:

Disable binding function.

Description:

Delete Binding group.

Syntax:

Parameters:

specifies the group id.

e.g. no bind 1

Show 4 more labels / short text on this page
bind · no bind · no bind · no bind <1-220>
Page 204 of the GE 82-POE user manual — Binding
Page 204 · click to enlarge
Page 204
Chapter 6Command Line Interface

Description:

Show Binding group information.

Syntax:

Parameters:

specifies the group id, null means all valid groups.

e.g. show bind 1

Description:

Add Binding group.

Syntax:

bind add <1-220> A:B:C:D:E:F <0-4094> A.B.C.D <1-26>

Parameters:

specifies the group id.

A.B.C.D specifies the MAC address.

specifies the VLAN id. 0 means don't care.

A.B.C.D specifies the Source IP address. 0.0.0.0 means don't care.

A.B.C.D specifies the IP Address.

specifies the Port id.

e.g.

Switch(config)# bind add 1 00:11:22:33:44:55 0 192.168.1.1 1

This Binding rule will permit all packet cross switch from device's IP is 192.168.1.1 and MAC is 00:11:22:33:44:55 and this device connect to switch port id=1.

show bind · show bind [<1-220>] · bind add

Page 205 of the GE 82-POE user manual — Display System PoE status
Page 205 · click to enlarge
Page 205
Chapter 6Command Line Interface

Power over Ethernet Commands (GE DS-82-PoE)

GE 82-POE — Power over Ethernet Commands (GE DS-82-PoE) diagram (page 205)
Fig. 106 · Power over Ethernet Commands (GE DS-82-PoE)

poe temperature-protection Enabling or disabling the PoE power supply over temperature protection

poe limit-mode Configure System PoE power limit mode information

poe enable Enabling or disabling the port POE injects function

poe priority Set port priority for the power supply management

poe maximum-power Enabling or disabling per port power output limit

Display System PoE status

Description:

Show System Power over Ethernet information

Example:

GE 82-POE — Display System PoE status diagram (page 205)
Fig. 107 · Display System PoE status

show poe · Command Level · Global Configuration

Page 206 of the GE 82-POE user manual — Power over Ethernet Commands (GE DS-82-PoE)
Page 206 · click to enlarge
Page 206
Chapter 6Command Line Interface

Description:

Show per PoE port information

Syntax:

show poe status [<port-list>]

Parameters:

specifies the ports to be set. If not entered, all ports are set.

Example 1:

GE 82-POE — Power over Ethernet Commands (GE DS-82-PoE) diagram (page 206)
Fig. 108 · Power over Ethernet Commands (GE DS-82-PoE)

Example 2:

GE 82-POE — Power over Ethernet Commands (GE DS-82-PoE) diagram (page 206)
Fig. 109 · Power over Ethernet Commands (GE DS-82-PoE)

show poe status · Command Level · Global Configuration

Page 207 of the GE 82-POE user manual — Configure PoE - System
Page 207 · click to enlarge
Page 207
Chapter 6Command Line Interface

Configure PoE Over Temperature Protection

Description:

Configure PoE over temperature protection to enable or disable

Syntax:

poe temperature-protection { enable / disable }

Parameters:

Enable PoE power budget change automatically by detected PoE unit temperature

Disable PoE power budget change automatically

Configure PoE - System

Description:

Configure System PoE power limit mode information

Syntax:

poe limit-mode { Port-Priority / Total-Limit }

Parameters:

Deliver PoE power by port priority setting

Set limit value of the total POE port provided power to the PDs.

Show 7 more labels / short text on this page
poe temperature-protection enable[x4] · Command Level · Global Configuration · poe limit-mode · Command Level · Global Configuration · [no] poe limit-mode
Page 208 of the GE 82-POE user manual — Configure PoE Over Temperature Protection
Page 208 · click to enlarge
Page 208
Chapter 6Command Line Interface

Example:

Switch(config)# poe limit-mode port-priority

GE 82-POE — Configure PoE Over Temperature Protection diagram (page 208)
Fig. 110 · Configure PoE Over Temperature Protection

Switch (config)# no poe limit-mode

GE 82-POE — Configure PoE Over Temperature Protection diagram (page 208)
Fig. 111 · Configure PoE Over Temperature Protection
Page 209 of the GE 82-POE user manual — Configure PoE -- Port
Page 209 · click to enlarge
Page 209
Chapter 6Command Line Interface

Configure PoE -- Port

Description:

Enabling or disabling the port POE injects function.

Command Level:

Syntax:

[no] poe enable [<port-list>]

Parameters:

specifies the ports to be set. If not entered, all ports are set.

Example:

Switch(config)# poe enable 1

GE 82-POE — Configure PoE -- Port diagram (page 209)
Fig. 112 · Configure PoE -- Port

Switch(config)# no poe enable 1

GE 82-POE — Configure PoE -- Port diagram (page 209)
Fig. 113 · Configure PoE -- Port

poe enable · Global Configuration · poe enable [<port-list>]

Page 210 of the GE 82-POE user manual — Configure PoE -- Port
Page 210 · click to enlarge
Page 210
Chapter 6Command Line Interface

Description:

Set port priority for the power supply management.

The command is configurable while "poe limit-mode" is set to "Port Priority"

Command Level:

Syntax:

poe priority { Critical | High | Low} [<port-list>]

Parameters:

{Critical | High | Low}

  • Critical - Indicates that operating the powered device is high.
  • HighIndicates that operating the powered device has medium priority.
  • LowIndicates that operating the powered device has low priority

specifies the ports to be set. If not entered, all ports are set.

Example:

Switch(config)# poe priority low 1

GE 82-POE — Configure PoE -- Port diagram (page 210)
Fig. 114 · Configure PoE -- Port

poe priority · Global Configuration

Page 211 of the GE 82-POE user manual — Configure PoE -- Port
Page 211 · click to enlarge
Page 211
Chapter 6Command Line Interface

Description:

Enabling or disabling per port power output limit.

The command is configurable while "poe limit-mode" is set to "Total-Limit"

Command Level:

Syntax:

poe maximum-power <1-15.4> [<port-list>]

no poe mximum-power [<port-list>]

Parameters:

specifies the ports to be set. If not entered, all ports are set.

Example:

Switch(config)# poe maximum-power 10 1

GE 82-POE — Configure PoE -- Port diagram (page 211)
Fig. 115 · Configure PoE -- Port

poe maximum-power · Global Configuration

Page 212 of the GE 82-POE user manual — Configure PoE -- Port
Page 212 · click to enlarge
Page 212
Chapter 6Command Line Interface
Page 213 of the GE 82-POE user manual — Forwarding & Filtering
Page 213 · click to enlarge
Page 213

Chapter 7 Switch Operation

Address Table

The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. This information comes from the learning process of Ethernet Switch.

Learning

When one packet comes in from any port, the Switch will record the source address, port no. And the other related information in address table. This information will be used to decide either forwarding or filtering for future packets.

Forwarding & Filtering

When one packet comes from some port of the Ethernet Switching, it will also check the destination address besides the source address learning. The Ethernet Switching will lookup the address-table for the destination address. If not found, this packet will be forwarded to all the other ports except the port, which this packet comes in. And these ports will transmit this packet to the network it connected. If found, and the destination address is located at different port from this packet comes in, the Ethernet Switching will forward this packet to the port where this destination address is located according to the information from address table. But, if the destination address is located at the same port with this packet comes in, then this packet will be filtered. Thereby increasing the network throughput and availability

Page 214 of the GE 82-POE user manual — Auto-Negotiation
Page 214 · click to enlarge
Page 214
Chapter 7Switch Operation

Store-and-Forward

Store-and-Forward is one type of packet-forwarding techniques. A Store-and- Forward Ethernet Switching stores the incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets occurrence, it is the best choice when a network needs efficiency and stability.

The Ethernet Switch scans the destination address from the packet-header, searches the routing table pro-vided for the incoming port and forwards the packet, only if required. The fast forwarding makes the switch attractive for connecting servers directly to the network, thereby increasing throughput and availability. However, the switch is most commonly used to segment existence hubs, which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters.

Due to the learning function of the Ethernet switching, the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets whose destination address is on the same segment as the source address. This confines network traffic to its respective domain and reduce the overall load on the network.

The Switch performs "Store and forward" therefore, no error packets occur. More reliably, it reduces the re-transmission rate. No packet loss will occur.

Auto-Negotiation

The STP ports on the Switch have built-in "Auto-negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset). This is done by detect the modes and speeds at the second of both device is connected and capable of, both 10Base-T and 100Base-TX devices can connect with the port in either Half- or Full- Duplex mode.

If attached device is100Base-TX port will set to:

10Mbps, no auto-negotiation 10Mbps.

10Mbps, with auto-negotiation 10/20Mbps (10Base-T/Full-Duplex)

100Mbps, no auto-negotiation 100Mbps

100Mbps, with auto-negotiation 100/200Mbps (100Base-TX/Full-Duplex)

Page 215 of the GE 82-POE user manual — Chapter 8 Power Over Ethernet Overview
Page 215 · click to enlarge
Page 215

Chapter 8 Power Over Ethernet Overview

What is PoE?

Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet, the most widely installed local area network technology adopted today. PoE allows the electrical power necessary for the operation of each end-device to be carried by data cables rather than by separate power cords. New network applications, such as IP Cameras, VoIP Phones, and Wireless Networking, can help enterprises improve productivity. It minimizes wires that must be used to install the network for offering lower cost, and less power failures.

IEEE802.3af also called Data Terminal equipment (DTE) power via Media dependent interface (MDI) is an international standard to define the transmission for power over Ethernet. The 802.3af is delivering 48V power over RJ-45 wiring. Besides 802.3af also define two types of source equipment: Mid-Span and End-Span.

  • Mid-Span

Mid-Span device is placed between legacy switch and the powered device. Mid-Span is tap the unused wire pairs 4/5 and 7/8 to carry power, the other four is for data transmit.

  • End-Span

End-Span device is direct connecting with power device. End-Span could also tap the wire 1/2 and 3/6.

Page 216 of the GE 82-POE user manual — How Power is Transferred Through the Cable
Page 216 · click to enlarge
Page 216
Chapter 8Power Over Ethernet Overview

PoE System Architecture

The specification of PoE typically requires two devices: the Powered Source Equipment (PSE) and the Powered Device (PD). The PSE is either an End-Span or a Mid- Span, while the PD is a PoE-enabled terminal, such as IP Phones, Wireless LAN, etc. Power can be delivered over data pairs or spare pairs of standard CAT-5 cabling.

How Power is Transferred Through the Cable

A standard CAT5 Ethernet cable has four twisted pairs, but only two of these are used for 10BASE-T and 100BASE-T. The specification allows two options for using these cables for power, shown in Figure 99 and Figure 100:

The spare pairs are used. Figure 99 shows the pair on pins 4 and 5 connected together and forming the positive supply, and the pair on pins 7 and 8 connected and forming the negative supply. (In fact, a late change to the spec allows either polarity to be used).

Figure 99Power Supplied over the Spare Pins
GE 82-POE — How Power is Transferred Through the Cable diagram (page 216)
Fig. 116 · How Power is Transferred Through the Cable
Page 217 of the GE 82-POE user manual — PoE System Architecture
Page 217 · click to enlarge
Page 217
Chapter 8Power Over Ethernet Overview

The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity.

Figure 100Power Supplied over the Data Pins
GE 82-POE — PoE System Architecture diagram (page 217)
Fig. 117 · PoE System Architecture

When to install PoE?

Consider the following scenarios:

  • You're planning to install the latest VoIP Phone system to minimize cabling building costs when your company moves into new offices next month.
  • The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their laptops through lunch, but the cost of electrical power to the outside is not affordable.
  • Management asks for IP Surveillance Cameras and business access systems throughout the facility, but they would rather avoid another electrician's payment.

References:

IEEE Std 802.3af-2003 (Amendment to IEEE Std 802.3-2002, including IEEE Std 802.3ae-2002), 2003 Page(s):0_1-121

White Paper on Power over Ethernet (IEEE802.3af)

Page 218 of the GE 82-POE user manual — Stages of powering up a PoE link
Page 218 · click to enlarge
Page 218
Chapter 8Power Over Ethernet Overview

http://www.poweroverethernet.com/articles.php?article_id=52

http://www.microsemi.com/PowerDsine/

http://www.linear.com/

The PoE Provision Process

While adding PoE support to networked devices is relatively painless, it should be realized that power cannot simply be transferred over existing CAT-5 cables. Without proper preparation, doing so may result in damage to devices that are not designed to support provision of power over their network interfaces.

The PSE is the manager of the PoE process. In the beginning, only small voltage level is induced on the port's output, till a valid PD is detected during the Detection period. The PSE may choose to perform classification, to estimate the amount of power to be consumed by this PD. After a time-controlled start-up, the PSE begins supplying the 48 VDC level to the PD, till it is physically or electrically disconnected. Upon disconnection, voltage and power shut down.

Since the PSE is responsible for the PoE process timing, it is the one generating the probing signals prior to operating the PD and monitoring the various scenarios that may occur during operation.

All probing is done using voltage induction and current measurement in return.

Stages of powering up a PoE link

GE 82-POE — Stages of powering up a PoE link diagram (page 218)
Fig. 118 · Stages of powering up a PoE link

Detection Measure whether powered device has the correct signature resistance of 15–33 kΩ 2.7-10.0 1.8–10.0

Classification Measure which power level class the resistor indicates 14.5-20.5 12.5–25.0

Startup Where the powered device will startup >42 >38

Microsemi /PowerDsine · Linear Tech

Page 219 of the GE 82-POE user manual — Operation
Page 219 · click to enlarge
Page 219
Chapter 8Power Over Ethernet Overview

Line Detection

Before power is applied, safety dictates that it must first be ensured that a valid PD is connected to the PSE's output. This process is referred to as "line detection", and involves the PSE seeking a specific, 25 KO signature resistor. Detection of this signature indicates that a valid PD is connected, and that provision of power to the device may commence.

The signature resistor lies in the PD's PoE front-end, isolated from the rest of the PD's circuitries till detection is certified.

Classification

Once a PD is detected, the PSE may optionally perform classification, to determine the maximal power a PD is to consume. The PSE induces 15.5-20.5 VDC, limited to 100 mA, for a period of 10 to 75 ms responded by a certain current consumption by the PD, indicating its power class.

The PD is assigned to one of 5 classes: 0 (default class) indicates that full 15.4 watts should be provided, 1-3 indicate various required power levels and 4 is reserved for future use. PDs that do not support classification are assigned to class 0. Special care must be employed in the definition of class thresholds, as classification may be affected by cable losses.

Classifying a PD according to its power consumption may assist a PoE system in optimizing its power distribution. Such a system typically suffers from lack of power resources, so that efficient power management based on classification results may reduce total system costs.

Start-up

Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full voltage capacity (44-57 Volts) over a minimal amount of time (above 15 microseconds).

A gradual startup is required, as a sudden rise in voltage (reaching high frequencies) would introduce noise on the data lines.

Once provision of power is initiated, it is common for inrush current to be experienced at the PSE port, due to the PD's input capacitance. A PD must be designed to cease inrush current consumption (of over 350 mA) within 50 ms of power provision startup.

Operation

During normal operation, the PSE provides 44-57 VDC, able to support a minimum of 15.4 watts power.

Page 220 of the GE 82-POE user manual — AC Disconnect
Page 220 · click to enlarge
Page 220
Chapter 8Power Over Ethernet Overview

Power Overloads

The IEEE 802.3af standard defines handling of overload conditions. In the event of an overload (a PD drawing a higher power level than the allowed 12.95 Watts), or an outright short circuit caused by a failure in cabling or in the PD, the PSE must shut down power within 50 to 75 milliseconds, while limiting current drain during this period to protect the cabling infrastructure. Immediate voltage drop is avoided to prevent shutdown due to random fluctuations.

Power Disconnection Scenarios

The IEEE 802.3af standard requires that devices powered over Ethernet be disconnected safely (i.e. power needs be shut down within a short period of time following disconnection of a PD from an active port).

When a PD is disconnected, there is a danger that it will be replaced by a non-PoE- ready device while power is still on. Imagine disconnecting a powered IP phone utilizing 48 VDC, then inadvertently plugging the powered Ethernet cable into a non- PoE notebook computer. What's sure to follow is not a pretty picture.

The standard defines two means of disconnection, DC Disconnect and AC Disconnect, both of which provide the same functionality - the PSE shutdowns power to a disconnected port within 300 to 400ms. The upper boundary is a physical human limit for disconnecting one PD and reconnecting another.

DC Disconnect

DC Disconnect detection involves measurement of current. Naturally, a disconnected PD stops consuming current, which can be inspected by the PSE. The PSE must therefore disconnect power within 300 to 400 ms from the current flow stop. The lower time boundary is important to prevent shutdown due to random fluctuations.

AC Disconnect

This method is based on the fact that when a valid PD is connected to a port, the AC impedance measured on its terminals is significantly lower than in the case of an open port (disconnected PD).

AC Disconnect detection involves the induction of low AC signal in addition to the 48 VDC operating voltage. The returned AC signal amplitude is monitored by the PSE at the port terminals. During normal operation, the PD's relatively low impedance lowers the returned AC signal while a sudden disconnection of this PD will cause a surge to the full AC signal level and will indicate PD disconnection.

Page 221 of the GE 82-POE user manual — Chapter 9 Troubleshooting
Page 221 · click to enlarge
Page 221

Chapter 9 Troubleshooting

This chapter contains information to help you solve common problems. If the Ethernet Switch is not functioning properly, make sure the Ethernet Switch was set up according to the instructions in this manual.

The Link LED is not lit

Solution:

Check the cable connection and remove duplex mode of the Ethernet Switch

Some stations cannot talk to other stations located on the other port

Solution:

Check the VLAN settings, trunk settings, or port enabled / disabled status.

Solution:

Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to half duplex, then the performance will be poor. Please also check the in/out rate of the port.

Why the Switch doesn't connect to the network?

Solution:

1. Check the LNK/ACT LED on the switch
2. Try another port on the Switch
3. Make sure the cable is installed properly

Performance is poor

Page 222 of the GE 82-POE user manual — Power Overloads
Page 222 · click to enlarge
Page 222
Chapter 9Troubleshooting
4. Make sure the cable is the right type
5. Turn off the power. After a while, turn on power again

100Base-TX port link LED is lit, but the traffic is irregular

Solution:

Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.

Switch does not power up

Solution:

1. AC power cord not inserted or faulty
2. Check that the AC power cord is inserted correctly
3. Replace the power cord If the cord is inserted correctly, check that the AC power source is working by connecting a different device in place of the switch.
4. If that device works, refer to the next step.
5. If that device does not work, check the AC power

While IP Address be changed or forgotten admin password –

To reset the IP address to the default IP Address “192.168.0.100” or reset the password to default value. Press the hardware reset button at the front panel about 10 seconds. After the device is rebooted, you can login the management WEB interface within the same subnet of 192.168.0.xx.

GE 82-POE — Power Overloads diagram (page 222)
Fig. 119 · Power Overloads

Reset

Page 223 of the GE 82-POE user manual — 1 BI_DA+ BI_DB+
Page 223 · click to enlarge
Page 223

Appendix A RJ-45 Pin Assignment

Switch's RJ-45 Pin Assignments

1 BI_DA+ BI_DB+

2 BI_DABI_DB-

3 BI_DB+ BI_DA+

4 BI_DC+ BI_DD+

5 BI_DCBI_DD-

6 BI_DBBI_DA-

7 BI_DD+ BI_DC+

8 BI_DDBI_DC-

Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.

1000Mbps, 1000Base T · Contact MDI MDI-X

Page 224 of the GE 82-POE user manual — MDI-X
Page 224 · click to enlarge
Page 224
Appendix ARJ-45 Pin Assignment

10/100Mbps, 10/100Base-TX

When connecting your 10/100Mbps Ethernet Switch to another switch, a bridge or a hub, a straight or crossover cable is necessary. Each port of the Switch supports auto-MDI/MDI-X detection. That means you can directly connect the Switch to any Ethernet devices without making a crossover cable. The following table and diagram show the standard RJ-45 receptacle/ connector and their pin assignments:

RJ-45 Connector pin assignment

MDI-X

1 Tx + (transmit) Rx + (receive)

2 Tx - (transmit) Rx - (receive)

3 Rx + (receive) Tx + (transmit)

4, 5 Not used

6 Rx - (receive) Tx - (transmit)

7, 8 Not used

The standard cable, RJ-45 pin assignment

1 2 3 4 5 6 7 8

8 7 6 5 4 3 2 1

The standard RJ-45 receptacle/connector

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:

Contact MDI · Media Dependant Interface · Media Dependant Interface-Cross

Page 225 of the GE 82-POE user manual — 8 SIDE 2
Page 225 · click to enlarge
Page 225
Appendix APower Over Ethernet Overview
Figure 101Straight-Through and Crossover Cable

Straight Cable SIDE 1 SIDE2 SIDE 1 1

1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown

1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown

8 SIDE 2

Crossover Cable SIDE 1 SIDE2 SIDE 1 1

1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown

1 = White / Green 2 = Green 3 = White / Orange 4 = Blue 5 = White / Blue 6 = Orange 7 = White / Brown 8 = Brown

8 SIDE 2

Please make sure your connected cables have the same pin assignment ands color as the above picture before deploying the cables into your network.

Page 226 of the GE 82-POE user manual — 10/100Mbps, 10/100Base-TX
Page 226 · click to enlarge
Page 226
Page 226 of the GE 82-POE user manual — 10/100Mbps, 10/100Base-TX
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE 82-POE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE 82-POE

Be the first to ask — other owners or our team will answer.

Original document

GE 82-POE manual PDF

226 pages·2.8 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…