

Copyright © 2010 GE Security, Inc.
This document may not be copied in whole or in part or otherwise reproduced without prior written consent from GE Security, Inc., except where specifically permitted under US and international copyright law.
Disclaimer The information in this document is subject to change without notice. GE Security, Inc. (“GE Security”) assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.gesecurity.com
This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental.
Trademarks and patents GE and the GE monogram are trademarks of General Electric Company.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at www.gesecurity.com
FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Manufacturer GE Security, Inc.
EU authorized manufacturing representative:
GE Security B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see: www.recyclethis.info
Contact information For contact information see our Web site: www.gesecurity.com
For contact information see our Web site: www.gesecurity.eu
Regulatory information N4131 · European Union directives




The GE Security GE-DS-82 and GE-DS-82-PoE are Ethernet Managed Switches with 8 10/100Mbps ports and 2 Gigabit TP/SFP fiber optical combo connective ability with robust layer 2 features. The description of these models is below:

Open the Managed Switch box and carefully unpack it. The box should contain the following items:
The Managed Switch x1
User’s manual CD x1
19” Rack mount accessory kit x1
If any of these items are missing or damaged, please contact your dealer immediately.
The GE Security GE-DS-82 Series of Managed Switches offers 8 Ethernet ports with 2 Gigabit TP / SFP combo ports. The type 8 Fast Ethernet ports of the GE-DS-82 and GE- DS-82-PoE are 10 / 100Base-TX copper (RJ-45). The two Gigabit TP / SFP combo ports of all models can be either 1000Base-T for 10/100/1000Mbps or 1000Base-SX/LX through SFP (Small Factor Pluggable) interface. The distance can be extended from 100 meters (TP), 550 meters (Multi-mode fiber), up to above 10/50/70/120 kilometers (Single-mode fiber).
The GE-DS-82 series of Managed Switches boast a high performance switch architecture that is capable of providing non-blocking switch fabric and wire-speed throughput as high as 5.6Gbps. It’s two built-in GbE uplink ports also offer incredible extensibility, flexibility and connectivity to the Core switches or Servers.

Cost-effective solution with SNMP monitor for Network deployment
Not only catering to the needs of easy WEB-based management but also the centralized SNMP application to monitor the status of Switch and traffic per port, GE Security releases the cost-effective Managed Switch. The key features are listed below:
Remote and Centralize Management installation
Afford the current network to grow and expand, the GE Security GE-DS-82 series provide advanced WEB and SNMP management interface to fill this kind of demand. With its built-in Web-based management, the GE-DS-82 series offers an easy-to-use, platform-independent management and configuration facility. It supports standard Simple Network Management Protocol (SNMP) and can be monitored via any standard-based management software.
For efficient management, via WEB interface the GE-DS-82 series can be programmed for basic switch management functions such as port speed configuration, Port Trunking, VLAN, Port Mirroring, Rapid Spanning Tree and Misc Configuration. Additionally, the firmware includes advanced features such as IGMP snooping, QoS (Quality of Service), broadcast storm and bandwidth control, to enhance bandwidth utilization.
The GE Security GE-DS-82 series offers comprehensive Access Control List (ACL) for enforcing security to the edge. Its protection mechanisms comprises of Port-based 802.1X user and device authentication. Moreover, the switch provides MAC filter and Static MAC for enforcing security policies to the edge. The administrators can now construct highly secured corporate networks with considerably less time and effort than before.
Powerful Security

Power over Ethernet of GE-DS-82-PoE
The PoE in-line power following the standard IEEE 802.3af makes the GE-DS-82-PoE able to power 8 PoE devices at a distance of up to 100 meters through the 4-pair Cat 5/5e UTP wire.
This User Manual is structured as follows:
INTRODUCTION Product description with features and specifications
INSTALLATION Explains the functions of the Managed Switch, and how to physically install it
SWITCH MANAGEMENT Contains information about the software operation of the Managed Switch
WEB-BASED MANAGEMENT Explains how to manage the Managed Switch by Web interface
CONSOLE MANAGEMENT Describes how to use the Console Management Interface
Explains how to manage the Managed Switch by Command Line Interface
SWITCH OPERATION Explains how to operate the Managed Switch
Introduces the IEEE 802.3af PoE standard and PoE provision of the Managed Switch.
TROUBLESHOOTING Explains how to troubleshoot the Managed Switch
APPENDIX A Contains cable information for the Managed Switch
Section Section Content · Physical Port

GE-DS-82-PoE · Layer 2 Features · Quality of Service

Multicast · Security · Management

Power over Ethernet (GE-DS-82-PoE Only)





Bandwidth Control Per port Ingress / Egress bandwidth control in steps of128Kbps
Access Control List Supports up to 220 rule entries
PoE Standard - IEEE 802.3af Power over Ethernet / PSE
PoE Power output - Per Port 48V DC, 350mA . Max. 15.4 watts


- 1000Base-LX / ZX: 10 / 15 / 20 / 30 / 40 / 50 / 60 / 70 / 120km (very on fiber transceiver or SFP module)

This section describes the hardware features and installation of the Managed Switch on the desktop or rack mount. For easier management and control of the Managed Switch, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Managed Switch, please read this chapter completely.
The unit front panel provides a simple interface for monitoring the Managed Switch. Figure 1 shows the front panels of the Managed Switches.

10/100Mbps TP Interface (GE-DS-82, GE-DS-82-PoE)
Port-1-Port-8: 10/100Base-TX Copper, RJ-45 Twist-Pair: Up to 100 meters.

Port-9, Port-10: 10/100/1000Base-T Copper, RJ-45 Twist-Pair: Up to 100 meters.
Port-9, Port-10: 1000Base-SX/LX mini-GBIC slot, SFP (Small Factor Pluggable) transceiver module: From 550 meters (Multi-mode fiber), up to 10/30/50/70/120 kilometers (Single-mode fiber).
At the left of front panel, the Reset button is designed to reboot the Managed Switch without turning the power off. The following table summarizes the Reset button functions:
Reset Button Pressed and Released Function
About 1-3 seconds Reboots the Managed Switch
Resets the Managed Switch to Factory Default configuration. The Managed Switch will then reboot and load the default settings as below:
Until the PWR LED goes out
The front panel LEDs provide instant status of port links, data activity and system power. They help monitor the system and aid in troubleshooting when necessary. The front panel LEDs are shown in Figure 2.

Gigabit TP Interface · Gigabit SFP Slots · Reset button



PoE In Use Orange
The rear panel of the Managed Switch includes an AC inlet power socket, which accepts input power from 100 to 240VAC, 50-60 Hz. Figure 4 shows the rear panel of the Managed Switch.


The console port is a DB9, RS-232 male serial port connector. It is an interface for connecting a terminal directly. The console port provides rich diagnostic information including IP Address setting, factory reset, port management, link status and system settings. Users can use the attached RS-232 cable in the package and connect to the console port on the device. After the connection, users can run any terminal emulation program (Hyper Terminal, ProComm Plus, Telix, Winterm and so on) to enter the startup screen of the device.
Console Port

This section describes how to install the Managed Switch and connect it as necessary. Please read the following instructions, and perform the procedures in the listed order.


A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the Managed Switch.
B. Connect the other end of the cable to the network devices (printer servers, workstations, routers etc).
A. Connect socket end of the power cable to the socket on the Managed Switch rear panel.
B. Connect the power cable plug to a standard wall outlet.
C. Switch the power switch on the rear panel to ON. When the Managed Switch receives power, the Power LED should light and remain solid Green.
Use the following instructions to install the Managed Switch in a 19-inch standard rack.



This section describes how to insert an SFP transceiver into an SFP slot.
SFP transceivers are hot pluggable and hot swappable. You can insert and remove a transceiver from any SFP port without powering down the Managed Switch, as shown in Figure 8.


Approved GE Security SFP Transceivers
The Managed Switch supports both single-mode and multi-mode SFP transceivers. The following list of approved GE Security SFP transceivers is correct at the time of publication:
1000Base-SX/LX SFP transceiver:

Before connecting the other switches, workstations or Media Converter:
Connect the fiber cable:
Remove the transceiver module




This chapter explains the methods that you can use to configure management access to the Managed Switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device (work-station or personal computer) and the system. It also contains information about port connection options.
This chapter covers the following topics:
o Network cables - Use standard network (UTP) cables with RJ45
connectors.
Summary

o Above PC with COM Port (DB-9 / RS-232) or USB-to-RS-232 converter
The Managed Switch gives you the flexibility to access and manage it using any or all of the following methods:
The Administration Console and Web browser interface support are embedded in the Managed Switch software and are available for immediate use. Each of these management methods has their own advantages and disadvantages. Table 1 compares the three management methods.

Web Browser • Ideal for configuring the switch remotely
SNMP Agent • Communicates with switch functions at the MIB level
Console • No IP address or subnet needed
The Managed Switch offers management features that allow users to manage the Managed Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer. After you set up your IP address for the switch, you can access the Managed Switch's Web interface applications directly in your Web browser by entering the IP address of the Managed Switch.
You can then use your Web browser to list and manage the Managed Switch configuration parameters from one central location, just as if you were directly connected to the Managed Switch's console port. Web Management requires either Microsoft Internet Explorer 6.0 or later, Safari or Mozilla Firefox 2.0 or later.
Method Advantages Disadvantages

The following shows how to start up the Web Management of the GE-DS-82 Managed Switch. Please note that the Managed Switch is configured through an Ethernet connection. Make sure the manager PC is set on the same IP subnet address.
For example, the default IP address of the GE-DS-82 Managed Switch is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.

Login to the managed Switch




You can use an external SNMP-based application to configure and manage the Managed Switch, such as Snip Network Manager, HP Open view Network Node Management (NNM) or What’s up Gold. This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string. If the SNMP Net-work management Station only knows the set community string, it can read and write to the Mobs. However, if it only knows the get community string, it can only read Mobs. The default gets and sets community strings for the Managed Switch are public.

The Administration Console is an internal, character-oriented, and command line user interface for performing system administration such as displaying statistics or changing option settings. Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch's console (serial) port.
There are two ways to use this management method: via direct access or modem port access. The following sections describe these methods. For more information about using the console, refer to Chapter 5: Console Management.

with Terminal emulation software



Serial Port 57600,8,n,1 RS-232
Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the Managed Switch console (serial) port.
When using this management method, a straight DB9 RS-232 cable is required to connect the switch to the PC. After making this connection, configure the terminal- emulation program to use the following parameters:

PC / Workstation · Managed Switch · Serial Port

You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.
The Managed Switch supports the following protocols:
A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the Managed Switch before you can establish access to it with a virtual terminal protocol.
Terminal emulation differs from a virtual terminal protocol in that you must connect a terminal directly to the console (serial) port.
To access the Managed Switch through a Telnet session:



Log on to the Console
Make sure the device finished booting. Once the telnet has connected to the device, the hyper terminal will display the login request.
Then, the following message asks the login user name and password. The factory default password as following and the login screen as following appear.


Now you can configure the Switch by Telnet. The management interface is exactly the same with RS-232 console management.
Simple Network Management Protocol (SNMP) is the standard management protocol for multi-vendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service.
All of the management application modules use the same Messaging Application Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (console port, for example) are immediately displayable by the other management methods (for example, SNMP agent of Web browser).
The management architecture of the switch adheres to the IEEE open standard. This compliance assures customers that the Managed Switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.

The Managed Switch offers management features that allow users to manage the Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Manager supports Internet Explorer 6.0. It is based on Java Applets with an aim to reduce network bandwidth consumption, enhance access speed, and present an easy viewing screen.
The Managed Switch can be configured through an Ethernet connection, make sure the manager PC is set on same the IP subnet address with the Managed Switch.

IP Address:
192.168.0.x

For example, the default IP address of the Managed Switch is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
If you have changed the default IP address of the Managed Switch to 192.168.1.1 with subnet mask 255.255.255.0 via console, then the manager PC should be set at 192.168.1.x (where x is a number between 2 and 254) to do the relative configuration on manager PC.
o Network cables - Use standard network (UTP) cables with RJ45
connectors.
o Above PC installed with a WEB Browser and a JAVA runtime
environment Plug-in.



The Menu on the left side of the Web page lets you access all the commands and statistics that the Switch provides.
The Main web page allows you to configure the Managed Switch. This section describes how to use the Managed Switch's Web browser interface to configure and manage it.
Near the top of the web page the web agent displays an image of the Managed Switch's ports. The Mode can be set to display different information for the ports, including Link up or Link down. Clicking on the image of a port opens the Port Control page.


The port states are illustrated as follows:
State Disabled Down Link
The Main menu is located on the left side of the Main Web Page. This is where all the configuration menus can be accessed.
RJ-45 Ports · SFP Ports · PoE Ports


Use the System menu items to display and configure basic administrative details of the Managed Switch. Under System the following topics are provided to configure and view the system information: This section has the following items:
SYSTEM INFORMATION Provides basic system description, including contact information
IP CONFIGURATION Sets the IP address for management access
SNMP CONFIGURATION Configure SNMP agent and SNMP Trap
FIRMWARE UPGRADE Upgrade the firmware via TFTP server or Web Brower file transfer
Save/View the Managed Switch configuration to remote host.
Upload the switch configuration from remote host.
FACTORY DEFAULT Reset the configuration of the Managed Switch
SYSTEM REBOOT Restarts the Managed Switch
The System information menu contains 2 fields - Basic and Misc Config.

The Basic System Info page provides information for the current device information. Basic System Info page helps a switch administrator to identify the model name, firmware / hardware version and MAC address.

This page includes the following fields:
MODEL NAME Displays the system name of the Managed Switch
DESCRIPTION Describes the Managed Switch
MAC ADDRESS Displays the unique hardware address assigned by manufacturer (default)
FIRMWARE VERSION Displays the Managed Switch's firmware version
HARDWARE VERSION Displays the current hardware version
Select Misc Config from the System Information screen and the screen shown in Figure 24 appears.
Basic · Misc Config


This page includes the following fields:
Type the number of seconds that an inactive MAC address remains in the switch's address table. The value is a multiple of 6.
MAC Address Age-out Time
Default is 300 seconds.
To configure broadcast storm control, enable it and set the upper threshold for individual ports. The threshold is the percentage of the port's total bandwidth used by broadcast traffic. When broadcast traffic for a port rises above the threshold you set, broadcast storm control becomes active.
Broadcast Storm Filter Mode
The valid threshold values are 1/2, 1/4, 1/8, 1/16 and OFF.
Default is "OFF".

To select broadcast storm Filter Packets type. If no packets types are selected, no filtering will occur. The Broadcast Storm Filter Mode will show OFF.
The selectable items as below:
Broadcast Storm Filter Packets Select
Provide Collision Retry Forever function "Disable" or 16, 32, 48 collision numbers on Managed Switch. If this function is disabled, when a packet meet a collision, the Managed Switch will retry 6 times before discard the packets. Otherwise, the Managed Switch will retry until the packet is successfully sent.
Default value is 16.
Provide MAC address table Hashing setting on Managed Switch; available options are CRC Hash and Direct Map.
Default mode is CRC-Hash.
802.1x protocol Enable / disable 802.1x protocol
Apply button Press the button to complete the configuration.
The Managed Switch is a network device, which needs to be assigned an IP address to be identified on the network. Users have to decide a means of assigning IP address to the Managed Switch.
What is an IP address?
Each device (such as a computer) which participates in an IP network needs a unique "address" on the network. It's similar to having a US mail address so other people have a know way to send you messages. An IP address is a four-byte number, which is usually written in "dot notation" - each of the bytes' decimal value is written as a number, and the numbers are separated by "dots" (aka periods). An example: 199.25.123.1
How do I get one for this box?
An employee called a “Network Administrator” assigns the IP addresses on most modern corporate nets. This person assigns IP addresses and is responsible for making sure that IP addresses are not duplicated - If this happens one or both machines with a duplicate address will stop working.
Another possibility is getting your address assigned to you automatically over the net via DHCP protocol. Enable DHCP function, and reset the machine. If your network is
Collision Retry Forever · Hash Algorithm

set up for this service, you will get an IP address assigned over the network. If you don't get an address in about 30 seconds, you probably don't have DHCP.
The IP Configuration includes the IP Address, Subnet Mask and Gateway. The Configured column is used to view or change the IP configuration. Fill up the IP Address, Subnet Mask and Gateway for the device. The screen in Figure 25 appears.

This page includes the following fields:
Enable or disable the DHCP client function.
When DHCP function is enabled, the Managed Switch will be assigned an IP address from the network DHCP server. The default IP address will be replaced by the assigned IP address on DHCP server. After the user clicks Apply, a popup dialog shows up to inform the user that when the DHCP client is enabled, the current IP will lose and user should find the new IP on the DHCP server.
Assign the IP address that the network is using.
If DHCP client function is enabled, this switch is configured as a DHCP client. The network DHCP server will assign the IP address to the switch and display it in this column.
The default IP is 192.168.0.100 or the user has to assign an IP address manually when DHCP Client is disabled.
IP Configuration · IP Address

Assign the subnet mask to the IP address.
If DHCP client function is disabled, the user has to assign the subnet mask in this column field.
Assign the network gateway for the switch.
If DHCP client function is disabled, the user has to assign the gateway in this column field.
The default gateway is 192.168.0.254.
The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the Transmission Control Protocol/Internet Protocol (TCP/IP) protocol suite. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth.

Subnet Mask · Gateway · SNMP Overview

An SNMP-managed network consists of four key components: Network management stations (NMSs), SNMP agents, Management information base (MIB) and Network- management protocol:
SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving a response.
An SNMP community is the group that devices and management stations running SNMP belong to. It helps define where information is sent. The community name is used to identify the group. A SNMP device or agent may belong to more than one SNMP community. It will not respond to requests from management stations that do not belong to one of its communities. SNMP default communities are:
Use this page to define management stations. You can also define a name, location, and contact person for the Managed Switch.
SNMP Overview · SNMP Community · System Options


This page includes the following fields:
An administratively assigned name for this managed node. By convention, this is the node's fully qualified domain name. A domain name is a text string drawn from the alphabet (A-Za-z), digits (0-9), minus sign (-). No space characters are permitted as part of a name. The first character must be an alpha character. And the first or last character must not be a minus sign.
The allowed string length is 0 to 255.
The physical location of this node (e.g., telephone closet, 3rd floor).
The allowed string length is 0 to 255, and the allowed content is the ASCII characters from 32 to 126.
The textual identification of the contact person for this managed node, together with information on how to contact this person.
The allowed string length is 0 to 255, and the allowed content is the ASCII characters from 32 to 126.
Indicates the SNMP mode operation. Possible modes are:

Community strings serve as passwords. See the table below.

This page includes the following fields:
Here you can define the new community string set and remove the unwanted community string.
ADD button Press the button to add the management SNMP community strings on the Managed Switch.
REMOVE button Press the button to remove the management SNMP community strings that you defined before on the Managed Switch.
A trap manager is a management station that receives the trap messages generated by the switch. If no trap manager is defined, no traps will be issued. To define a management station as a trap manager, assign an IP address, enter the SNMP community strings, and select the SNMP trap version.

Community Strings · Community Strings · Trap Managers

This page includes the following fields:
85 Enter the IP address of the trap manager.
Community Enter the community string for the trap station.
Configure SNMPv3 groups table on this page. The entry index keys are Security Model and Security Name.
The SNMPv3 Groups Configuration screen in Figure 30 appears.

This page includes the following fields:
Group Name: A string identifying the group name that this entry should belong to.
The allowed string length is 1 to 15
V1 | V2c | USM Indicates the security model that this entry should belong to. Possible security models are:
v1: Reserved for SNMPv1.
v2c: Reserved for SNMPv2c.
usm: User-based Security Model (USM).
SNMPv3 Groups · Object Description

Security Name: A string identifying the security name that this entry should belong to.
The allowed string length is 1 to 15
Remove Check to delete the entry. It will be deleted during the next save.
Configure the SNMPv3 views table on this page. The entry index keys are View Name and OID Subtree.
The SNMPv3 Views Configuration screen in Figure 31 appears.

This page includes the following fields:
View Name: A string identifying the view name that this entry should belong to.
The allowed string length is 1 to 15
included: An optional flag to indicate that this view subtree should be included.
excluded: An optional flag to indicate that this view subtree should be excluded.
SNMPv3 View · Object Description

View Subtree The OID defining the root of the subtree to add to the named view. The allowed OID length is 1 to 128. The allowed string content is digital number or asterisk(*)
View Mask (Hexadecimal Digits):
View mask is defined in order to reduce the amount of configuration information required when fine-grained access control is required (e.g., access control at
The object instance level)
Configure the SNMPv3 access table on this page. The entry index keys are Group Name, Security Model and Security Level.
The SNMPv3 Accesses Configuration screen in Figure 32 appears.

This page includes the following fields:
A string identifying the group name that this entry should belong to.
Group Name:
The allowed string length is 1 to 15.
Indicates the security model that this entry should belong to. Possible security models are:
v1: Reserved for SNMPv1.
V1 | V2c | USM:
v2c: Reserved for SNMPv2c.
SNMPv3 Access · Object Description

Indicates the security model that this entry should belong to. Possible security models are:
SNMP Access:
NoAuth: None authentication and none privacy.
Auth: Authentication and none privacy.
Authpriv: Authentication and privacy.
The name of the MIB views defining the MIB objects for which this request may request the current values.
Read View:
The allowed string length is 1 to 16.
The name of the MIB views defining the MIB objects for which this request may potentially SET new values.
Write View:
The allowed string length is 1 to 16.
Notify View: Set up the notify view.
Remove Check to delete the selected entry. It will be deleted during the next save.
Configure SNMPv3 users table on this page. The entry index keys are Engine ID and User Name.
The SNMPv3 Users Configuration screen in Figure 33 appears.

SNMPv3 usm-user

This page include the following fields:
SNMP User Name: A string identifying the user name that this entry should belong to. The allowed string length is 1 to 15.
Indicates the authentication protocol that this entry should belong to. Possible authentication protocol are:
None: None authentication protocol.
Auth Type:
MD5: An optional flag to indicate that this user using MD5 authentication protocol.
The value of the security level cannot be modified if an entry already exists. That means must first ensure that the value is set correctly.
A string identifying the authentication pass phrase.
Auth Key (8-32):
For MD5 authentication protocol, the allowed string length is 8 to 32.
A string identifying the privacy pass phrase.
Private Key (8-32):
The allowed string length is 8 to 32.
Remove Check to delete the selected entry. It will be deleted during the next save.
It provides the functions allowing the user to update the switch firmware via the Trivial File Transfer Protocol (TFTP) server. Before updating, make sure the TFTP server is ready and the firmware image is located on the TFTP server.
The Firmware Upgrade page provides the functions to allow a user to update the Managed Switch firmware from the TFTP server in the network. Before updating, make sure you have your TFTP server ready and the firmware image is on the TFTP server. The screen in Figure 34 appears.
Use this menu to download a file from specified TFTP server to the Managed Switch.

Object Description · TFTP Firmware Upgrade

This page includes the following fields:
TFTP Server IP Address Type in your TFTP server IP.
Firmware File Name Type in the name of the firmware image file to be updated.
The HTTP Firmware Upgrade page contains fields for downloading system image files from the Local File browser to the device. The Web Firmware Upgrade screen in Figure 35 appears.

To open the Firmware Upgrade screen, do the following:

HTTP Firmware Upgrade

You can restore a previous backup configuration from the TFTP server to recover the settings. Before doing that, you must locate the image file on the TFTP Server first and the Managed Switch will download the flash image.

This page includes the following fields:
TFTP Server IP Address Type in your TFTP server IP.
Restore File Name Type in the correct file name for restoring.
TFTP Restore Configuration

You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later. It helps you to avoid wasting time on configuring the settings by backing up the configuration.

This page includes the following fields:
TFTP Server IP Address Type in your TFTP server IP.
Backup File Name Type in the file name.
TFTP Backup Configuration

Reset switch to default configuration. Click reset to reset all configurations to the default value.

Reboot the switch. Click reboot to reboot the system.

System Reboot

The Syslog Setting page allows you to configure the logging of messages that are sent to remote syslog servers or other management stations. You can also limit the event messages sent to only those messages below a specified level.

This page includes the following settings:
Syslog Server IP IP address of syslog server.
Log level None: never send syslog message to syslog serverme, and Max Age parameters of the root bridge, regardless of how it is configured.
All: send all syslog message to syslog server.
In Port control you can configure the settings of each port to control the connection parameters, and the status of each port is listed beneath.
Port Control


This page includes the following fields:
Port Use the scroll bar and click on the port number to choose the port to be configured.
State Current port state. The port can be set to disable or enable mode. If the port state is set as 'Disable', it will not receive or transmit any packet.
Auto and Force. Being set as Auto, the speed and duplex mode are negotiated automatically. When you set it as Force, you have to set the speed and duplex mode manually.
Speed It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set as Auto, this column is read-only.
Duplex It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set as Auto, this column is read-only.
Whether or not the receiving node sends feedback to the sending node is determined by this item. When enabled, once the device exceeds the input data rate of another device, the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time. When disabled, the receiving device will drop the packet if too much to process.
Negotiation · Flow Control

Port-1 - Port-24, supports by-port ingress and egress rate control.
For example, assume port 1 is 10Mbps, users can set its effective egress rate at 1Mbps and ingress rate at 500Kbps. Device will perform flow control or backpressure to confine the ingress rate to meet the specified rate.
The valid range is 0 - 8000. The unit is 128K.
The valid range is 0 - 8000. The unit is 128K.
1 -8000: valid rate value.
A port in security mode will be "locked" without permission of address learning. Only the incoming packets with SMAC already existing in the address table can be forwarded normally.
User can disable the port from learning any new MAC addresses, then use the static MAC addresses screen to define a list of MAC addresses that can use the secure port. Enter the settings, then click Apply button to change on this page.
User can disable/Enable port broadcast storm filtering option by port.
The filter mode and filter packets type can be select in Switch Setting > Misc Config page.
Jumbo Frame User can disable/Enable port jumbo frame option by port. When port jumbo frame is enable, the port forward jumbo frame packet.
Rate Control · Security

This page displays current port configurations and operating status - it is a ports' configurations summary table. Via the summary table, you can find the status of each port clear at a glance, like Port Link Up/Link Down status, negotiation, Link Speed, Rate Control, Duplex mode and Flow Control.

The following chart shows the current statistic information that displays the real-time packet transfer status for each port. The user might use the information to plan and implement the network, or check and find problems when collisions or heavy traffic occurs.


This page includes the following fields:
Port The port number.
Link The status of linking-'Up' or 'Down'
State Set by Port Control. When the state is disabled, the port will not transmit or receive any packet.
Tx Good Packet The counts of transmitting good packets via this port.
The counts of transmitting bad packets (including undersize [less than 64 octets], oversize, CRC Align errors, fragments and jabbers packets) via this port.
Rx Good Packet The counts of receiving good packets via this port.
Rx Bad Packet The counts of receiving good packets (including undersize [less than 64 octets], oversize, CRC error, fragments and jabbers) via this port.
Tx Abort Packet The aborted packet while transmitting.
Packet Collision The counts of collision packet.
Packet Dropped The counts of dropped packet.
Rx Bcast Packet The counts of broadcast packet.
Rx Mcast Packet The counts of multicast packet.
Tx Bad Packet

The Port Sniffer (mirroring) is a method for monitor traffic in switched networks. Traffic through a port can be monitored by one specific port. That is, traffic goes in or out a monitored port will be duplicated into the sniffer port.

Configuring the port mirroring by assigning a source port from which to copy all packets and a destination port where those packets will be sent.


This page includes the following fields:
Select a sniffer mode:
It' means Analysis port can be used to see the traffic on another port you want to monitor. You can connect Analysis port to LAN analyzer or netxray.
The port you want to monitor. The monitor port traffic will be copied to the Analysis port. You can select one monitor per ports in the switch. User can choose which port that they want to monitor in only one sniffer type.
If you want to disable the function, you must select the monitor port to none.
Sniffer Type · Analysis (Monitoring) Port · Monitored Port

There are two protected port groups, ports in different groups can't communicate.
In the same group, protected ports can't communicate with each other, but can communicate with unprotected ports. Unprotected ports can communicate with any ports, including protected ports

This page includes the following fields:
Port ID Identify the Managed Switch interface.
Enable the Protected function on the selected port.
If the check box is not shown as
, then this port a unprotected port and it can communicate with any ports - including protected ports
Group 1 Set the protected port to be Group 1 member.
Group 2 Set the protected port to be Group 2 member.
Protected

A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the physical layout. VLAN can be used to combine any collection of LAN segments into an autonomous user group that appears as a single LAN. VLAN also logically segment the network into different broadcast domains so that packets are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular subnet, although not necessarily.
VLAN can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific domains.
A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently communicate with each other are assigned to the same VLAN, regardless of where they are physically on the network. Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to only members of the VLAN on which the broadcast was initiated.
The Managed Switch supports IEEE 802.1Q (tagged-based) and Port-Base VLAN setting in web management page. In the default configuration, VLAN support is "802.1Q".
Port-based VLAN limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or an entire department.
On port-based VLAN.NIC do not need to be able to identify 802.1Q tags in packet headers. NIC send and receive normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using normal Ethernet protocols. Even though this is always the case, when the destination for a packet lies

on another switch port, VLAN considerations come into play to decide if the packet is dropped by the Switch or delivered.
IEEE 802.1Q (tagged) VLAN are implemented on the Switch. 802.1Q VLAN require tagging, which enables them to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).
VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and this includes broadcast, multicast and unicast packets from unknown sources.
VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between stations that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally.
Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally.
Some relevant terms:
- Tagging - The act of putting 802.1Q VLAN information into the header of a packet.
- Untagging - The act of stripping 802.1Q VLAN information out of the packet header.
The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC address. Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field is equal to 0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used by 802.1p. The VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094 unique VLAN can be identified.
The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally contained in the packet is retained.

802.1Q Tag
User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits
TPID (Tag Protocol Identifier) TCI (Tag Control Information)
2 bytes 2 bytes
Source Address VLAN TAG Ethernet
6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes
The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether Type/Length or Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC) must be recalculated.
Adding an IEEE802.1Q Tag
Dest. Addr. Src. Addr. Length/E. type Data Old CRC
Dest. Addr. Src. Addr. E. type Tag Length/E. type Data New CRC
Priority CFI VLAN ID
Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant network device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices (and indeed, the entire network - if all network devices are 802.1Q compliant).
Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no VLAN are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this PVID, in so far as VLAN are concerned. Tagged packets are forwarded according to the VID contained within the tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the VID is.
Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID are different the switch will drop the packet. Because of the existence of the PVID for untagged packets and the VID

for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.
A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to store them.
Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware device before packets are transmitted - should the packet to be transmitted have a tag or not? If the transmitting port is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-aware device, the packet should be tagged.
The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on the Switch to the "default". As new VLAN are configured in Port-based mode, their respective member ports are removed from the "default."
In order to use VLAN segmentation in conjunction with port link aggregation groups, you can first set the port link aggregation group(s), and then you may configure VLAN settings. If you wish to change the port link aggregation grouping with VLAN already in place, you will not need to reconfigure the VLAN settings after changing the port link aggregation group settings. VLAN settings will automatically change in conjunction with the change of the port link aggregation group settings.
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still plug into the same switch physically.
The Managed Switch supports Port-based and 802.1Q (Tagged-based) VLAN in the web management page. The default configuration, VLAN support is "802.1Q".


Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored.
In order for an end station to send packets to different VLANs, it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN-aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet, such as the protocol.


Create a VLAN and add member ports to it
By adding ports to the VLAN you have created one port-based VLAN group completely.


This page includes the following fields:
VLAN Name Use this optional field to specify a name for the VLAN. It can be up to 16 alphanumeric characters long, including blanks.
You can configure the ID number of the VLAN by this item. This field is used to add VLANs one at a time. The VLAN group ID and available range is 2-4094.
Port Indicate port 1 to port 26.
Add Defines the interface as a Port-Based member of a VLAN. Member
Remove Forbidden ports are not included in the VLAN.
Group ID

Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create a VLAN across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a "tag" into the Ethernet frames. Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.
You can create and delete Tag-based VLAN. There are 256 VLAN groups to provide configure. Enable 802.1Q VLAN, the all ports on the switch belong to default VLAN, VID is 1. The default VLAN can't be deleting.
Understand nomenclature of the Switch
Every port on an 802.1Q compliant switch can be configured as tagged or untagged.
Tagged Ports with tagging enabled will put the VID number, priority and other VLAN information into the header of all packets that flow into those ports. If a packet has previously been tagged, the port will not alter the packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by other 802.1Q compliant devices on the network to make packet-forwarding decisions.
Untagged Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into those ports. If the packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is only used internally within the Switch). Untagging is used to send packets from an 802.1Q-compliant network device to a non-compliant network device.
Income Frame is tagged Income Frame is untagged
Leave port is tagged Frame remains tagged Tag is inserted
Leave port is untagged Tag is removed Frame remain untagged
Frame Income · Frame Leave


VLAN Group Configuration




This page includes the following fields:
VLAN Name Use this optional field to specify a name for the VLAN. It can be up to 16 alphanumeric characters long, including blanks.
You can configure the ID number of the VLAN by this item. This field is used to add VLANs one at a time.
The VLAN group ID and available range is 2-4094.
Port Indicate port 1 to port 26.
Untag Packets forwarded by the interface are untagged.
Defines the interface as a tagged member of a VLAN. All packets forwarded by the interface are tagged. The packets contain VLAN information.
UnTag Member · Tag

This page is used for configuring the Switch port VLAN. The VLAN per Port Configuration page contains fields for managing ports that are part of a VLAN. The port default VLAN ID (PVID) is configured on the VLAN Port Configuration page. All untagged packets arriving to the device are tagged by the ports PVID.
This section provides 802.1Q Ingress Filter of each port from the Switch, the screen in Figure 53 appears.

This page includes the following fields:
NO Indicate port 1 to port 26.
Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for accommodating devices that you want to participate in the VLAN but that don't support tagging.
The switch each port allows user to set one VLAN ID, the range is 1-255, default VLAN ID is 1.
The VLAN ID must as same as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.
VLAN Filter

Ingress filtering lets frames belonging to a specific VLAN to be forwarded if the port belongs to that VLAN.
Enable: Forward only packets with VID matching this port's configured VID.
Disable: Disable Ingress filter function.
Drop untagged frame.
Disable: Acceptable all Packet.
Enable: Only packet with match VLAN ID can be permission to go through the port.
Apply button Press the button to save configurations.
IEEE 802.1Q Tunneling (QinQ) is designed for service providers carrying traffic for multiple customers across their networks. QinQ tunneling is used to maintain customer-specific VLAN and Layer 2 protocol configurations even when different customers use the same internal VLAN IDs. This is accomplished by inserting Service Provider VLAN (SPVLAN) tags into the customer's frames when they enter the service provider's network, and then stripping the tags when the frames leave the network.
A service provider's customers may have specific requirements for their internal VLAN IDs and number of VLANs supported. VLAN ranges required by different customers in the same service-provider network might easily overlap, and traffic passing through the infrastructure might be mixed. Assigning a unique range of VLAN IDs to each customer would restrict customer configurations, require intensive processing of VLAN mapping tables, and could easily exceed the maximum VLAN limit of 4096.

Ingress Filtering 1 · Ingress Filtering 2

The Managed Switch supports multiple VLAN tags and can therefore be used in MAN applications as a provider bridge, aggregating traffic from numerous independent customer LANs into the MAN (Metro Access Network) space. One of the purposes of the provider bridge is to recognize and use VLAN tags so that the VLANs in the MAN space can be used independent of the customers' VLANs. This is accomplished by adding a VLAN tag with a MAN-related VID for frames entering the MAN. When leaving the MAN, the tag is stripped and the original VLAN tag with the customer- related VID is again available.
This provides a tunneling mechanism to connect remote costumer VLANs through a common MAN space without interfering with the VLAN tags. All tags use EtherType 0x8100 or 0x88A8, where 0x8100 is used for customer tags and 0x88A8 are used for service provider tags.
In cases where a given service VLAN only has two member ports on the switch, the learning can be disabled for the particular VLAN and can therefore rely on flooding as the forwarding mechanism between the two ports. This way, the MAC table requirements are reduced.
The QinQ VLAN \ QinQ Port Setting screen in Figure 54 appears.

Q-in-Q Port Setting

This page includes the following fields:
Enable Sets the Managed Switch to QinQ mode, and allows the QinQ tunnel port to be configured.
Disable The Managed Switch operates in its normal VLAN mode. QinQ
The default is for the Managed Switch to function in Disable mode.
The Tag Protocol Identifier (TPID) specifies the ethertype of incoming packets on a tunnel access port.
Default : 802.1Q Tag.
Check: Sets the Port to QinQ mode. Or the port operates in its normal VLAN mode.
Default: Un-check.
Check Configures IEEE 802.1Q tunneling (QinQ) for an uplink port to another device within the service provider network. QinQ Uplink
Cancel Configures IEEE 802.1Q tunneling (QinQ) for a client access port to segregate and preserve customer VLAN IDs for traffic crossing the service provider network.
Business customers of service providers often have specific requirements for VLAN IDs and the number of VLANs to be supported. The VLAN ranges required by different customers in the same service-provider network might overlap, and traffic of customers through the infrastructure might be mixed. Assigning a unique range of VLAN IDs to each customer would restrict customer configurations and could easily exceed the VLAN limit (4096) of the IEEE 802.1Q specification.
Using the QinQ feature, service providers can use a single VLAN to support customers who have multiple VLANs. Customer VLAN IDs are preserved, and traffic from different customers is segregated within the service-provider network, even when they appear to be in the same VLAN. Using QinQ expands VLAN space by using a VLAN-in-VLAN hierarchy and retagging the tagged packets. A port configured to support QinQ is called a QinQ user-port. A port configured to support QinQ Uplink is called a QinQ uplink-port.
QinQ TPID · Port QinQ · Q-in-Q Tunnel Setting


GVRP (GARP VLAN Registration Protocol or Generic VLAN Registration Protocol) is a protocol that facilitates control of virtual local area networks (VLANs) within a larger network. GVRP conforms to the IEEE 802.1Q specification, which defines a method of tagging frames with VLAN configuration data. This allows network devices to dynamically exchange VLAN configuration information with other devices.

Enable global GVRP function: select GVRP enable "Enable".
Enable port GVRP function: select GVRP checkbox for special port.
To configure GVRP


This page includes the following fields:
GVRP Enable global GVRP function
Port Indicate port 1 to port 10.
Port GVRP Enable selected port GVRP function

The GVRP Table can be used to display dynamic VLANs from being learned via GVRP.

This page includes the following fields:
Display the learned VLANs via GVRP protocol on GVRP enabled ports.
The Managed Switch allows displaying up to 128 dynamic VLAN entries.
Port Members Identify the GVRP enabled port that dynamic VLAN is learned from.
GVRP Table

The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and the system will auto-detect the connected device that is running STP or RSTP protocol.
The Spanning Tree protocol can be used to detect and disable network loops, and to provide backup links between switches, bridges or routers. This allows the switch to interact with other bridging devices in your network to ensure that only one route exists between any two stations on the network, and provide backup links which automatically take over when a primary link goes down. The spanning tree algorithms supported by this switch include these versions:
The IEEE 802.1D Spanning Tree Protocol and IEEE 802.1W Rapid Spanning Tree Protocol allow for the blocking of links between switches that form loops within the network. When multiple links between switches are detected, a primary link is established. Duplicated links are blocked from use and become standby links. The protocol allows for the duplicate links to be used in the event of a failure of the primary link. Once the Spanning Tree Protocol is configured and enabled, primary links are established and duplicated links are blocked automatically. The reactivation of the blocked links (at the time of a primary link failure) is also accomplished automatically without operator intervention.
This automatic network reconfiguration provides maximum uptime to network users. However, the concepts of the Spanning Tree Algorithm and protocol are a complicated and complex subject and must be fully researched and understood. It is possible to cause serious degradation of the performance of the network if the Spanning Tree is incorrectly configured. Please read the following before making any changes from the default values.
The Switch STP performs the following functions:

Bridge Protocol Data Units
For STP to arrive at a stable network topology, the following information is used:
STP communicates between switches on the network using Bridge Protocol Data Units (BPDUs). Each BPDU contains the following information:
The switch sends BPDUs to communicate and construct the spanning-tree topology. All switches connected to the LAN on which the packet is transmitted will receive the BPDU. BPDUs are not directly forwarded by the switch, but the receiving switch uses the information in the frame to calculate a BPDU, and, if the topology changes, initiates a BPDU transmission.
The communication between switches via BPDUs results in the following:
Creating a Stable STP Topology
To make the root port the fastest link. If all switches have STP enabled with default settings, the switch with the lowest MAC address in the network will become the root switch. By increasing the priority (lowering the priority number) of the best switch, STP can be forced to select the best switch as the root switch.

When STP is enabled using the default parameters, the path between source and destination stations in a switched network might not be ideal. For instance, connecting higher-speed links to a port that has a higher number than the current root port can cause a root-port change.
The BPDUs take some time to pass through a network. This propagation delay can result in topology changes where a port that transitioned directly from a Blocking state to a Forwarding state could create temporary data loops. Ports must wait for new network topology information to propagate throughout the network before starting to forward packets. They must also wait for the packet lifetime to expire for BPDU packets that were forwarded based on the old topology. The forward delay timer is used to allow the network topology to stabilize after a topology change. In addition, STP specifies a series of states a port must transition through to further ensure that a stable network topology is created after a topology change.
Each port on a switch using STP exists is in one of the following five states:
A port transitions from one state to another as follows:
STP Port States


You can modify each port state by using management software. When you enable STP, every port on every switch in the network goes through the blocking state and then transitions through the states of listening and learning at power up. If properly configured, each port stabilizes to the forwarding or blocking state. No packets (except BPDUs) are forwarded from, or received by, STP enabled ports until the forwarding state is enabled for that port.
A simple illustration of three switches connected in a loop is depicted in the following figure. In this example, you can anticipate some major network problems if the STP assistance is not applied.
If switch A broadcasts a packet to switch B, switch B will broadcast it to switch C, and switch C will broadcast it to back to switch A and so on. The broadcast packet will be passed indefinitely in a loop, potentially causing a network failure. In this example, STP breaks the loop by blocking the connection between switch B and C. The decision to block a particular connection is based on the STP calculation of the most current Bridge and Port settings.
Now, if switch A broadcasts a packet to switch C, then switch C will drop the packet at port 2 and the broadcast will end there. Setting-up STP using values other than the defaults, can be complex. Therefore, you are advised to keep the default factory settings and STP will automatically assign root bridges/ports and block loop connections. Influencing STP to choose a particular switch as the root bridge using

the Priority setting, or influencing STP to choose a particular port to block using the Port Priority and Port Cost settings is, however, relatively straight forward.

In this example, only the default STP values are used.


The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 4) on switch A are connected to one (optional) Gigabit port on both switch B and C. The redundant link between switch B and C is deliberately chosen as a 100 Mbps Fast Ethernet link (default port cost = 19). Gigabit ports could be used, but the port cost should be increased from the default to ensure that the link between switch B and switch C is the blocked link.
The Switch allows for two levels of operation: the switch level and the port level. The switch level forms a spanning tree consisting of links between one or more switches. The port level constructs a spanning tree consisting of groups of one or more ports. The STP operates in much the same way for both levels.
On the port level, STP sets the Root Port and the Designated Ports.
The following are the user-configurable STP parameters for the switch level:
A combination of the User-set priority and the switch's MAC address.
Bridge Identifier (Not user configurable except by setting priority below)
The Bridge Identifier consists of two parts:
a 16-bit priority and a 48-bit Ethernet MAC address 32768 + MAC.
A relative priority for each switch - lower numbers give a higher priority and a greater chance of a given switch being elected as the root bridge.
Hello Time The length of time between broadcasts of the hello message by the switch. 2 seconds
Measures the age of a received BPDU for a port and ensures that the BPDU is discarded when its age exceeds the value of the maximum age timer.
The amount time spent by a port in the learning and listening states waiting for a BPDU that may return the port to the blocking state.

The following are the user-configurable STP parameters for the port or port group level:
A relative priority for each switch - lower numbers give a higher priority and a greater chance of a given switch being elected as the root bridge.
200,000-100Mbps Fast Ethernet ports
A value used by STP to evaluate paths - STP calculates path costs and selects the path with the minimum cost as the active path.
20,000-1000Mbps Gigabit Ethernet ports
Enable state STP disabled for all ports
Observe the following formulas when setting the above parameters:
This section provides RSTP-System Configuration from the Switch, the screen in Figure 61 appears.


This page includes the following fields:
RSTP mode The user must enable the RSTP function first before configuring the related parameters.
A value used to specify the spanning tree protocol, the original spanning tree protocol (STP, 802.1d) or the rapid spanning tree protocol (RSTP, 802.1w).
The switch with the lowest value has the highest priority and is selected as the root. If the value is changed, the user must reboot the switch.
The value must be a multiple of 4096 according to the protocol standard rule.
The number of seconds a switch waits without receiving Spanning-tree Protocol configuration messages before attempting a reconfiguration.
Enter a value between 6 through 40.
The time that controls the switch to send out the BPDU packet to check RSTP current status.
Enter a value between 1 through 10.
The number of seconds a port waits before changing from its Rapid Spanning-Tree Protocol learning and listening states to the forwarding state.
Forward Delay Time (4-30)
Enter a value between 4 through 30.

2 x (Forward Delay Time value -1) > = Max Age value >= 2 x (Hello Time value +1).
This page provides a status overview for all RSTP bridge instances.
The displayed table contains a row for each RSTP bridge instance, where the column displays the following information:
The RSTP Bridge Status screen in Figure 62 appears.

Root Bridge Information

This page includes the following fields:
Priority The bridge identifier of the root bridge. It is made up from the bridge priority and the base MAC address of the bridge.
MAC Address The bridge identifier of the root bridge. It is made up from the bridge priority and the base MAC address of the bridge.
Root Path Cost For the Root Bridge this is zero. For all other Bridges, it is the sum of the Port Path Costs on the least cost path to the Root Bridge.
Root Port The switch port currently assigned the root port role.
Maximum Age Path Cost to the Designated Root for the Root Bridge.
Hello Time Minimum time between transmissions of Configuration BPDUs.
Forward Delay Derived value of the Root Port Bridge Forward Delay parameter.
This web page provides the port configuration interface for RSTP. You can assign higher or lower priority to each port. Rapid spanning tree will have the port with the higher priority in forwarding state and block other ports to make certain that there is no loop in the LAN.


This page includes the following fields:
The cost of the path to the other bridge from this transmitting bridge at the specified port.
Enter a number 1 through 200,000,000.
Decide which port should be blocked by setting its priority as the lowest. Enter a number between 0 and 240.
The value of priority must be the multiple of 16.
The rapid state transitions possible within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge (i.e. it is served by a point-to-point LAN segment), or can be connected to two or more bridges (i.e. it is served by a shared medium LAN segment). This function allows the P2P status of the link to be manipulated administratively.
The port directly connected to end stations won't create bridging loop in the network. To configure the port as an edge port, set the port to "YES" status.
The port includes the STP mathematic calculation.
By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost according to the values shown below.

Recommended STP Path Cost Range
Port Type IEEE 802.1D-1998 IEEE 802.1w-2001
Fast Ethernet 10-60 20,000-2,000,000
Gigabit Ethernet 3-10 2,000-200,000
Recommended STP Path Cost Range
Port Type Link Type IEEE 802.1D-1998 IEEE 802.1w-2001
Fast Ethernet Half Duplex
Gigabit Ethernet Full Duplex
Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable. The Managed Switch supports two types of port trunk technology:
The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs, move the link to that Link Aggregation Group, and enable its transmission and reception functions in an orderly manner. Link aggregation lets you group up to eight consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the network. LACP operation requires full-duplex mode, more detail information refers to IEEE 802.3ad.


This section provides Port Trunk-Aggregator Setting of each port from the Managed Switch, the screen in Figure 64 appears.
Figure 64: Port Trunk-Aggregator setting interface (two ports are added to the left field with LACP enabled)


This page includes the following fields:
A value, which is used to identify the active LACP. The Managed Switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group.
Group ID There are 13 trunk groups to be selected. Assign the "Group ID" to the trunk group.
This column field allows the user to type in the total number of active port up to four. With LACP static trunk group, e.g. you assign four ports to be the members of a trunk group whose work ports column field is set as two; the exceed ports are standby/redundant ports and can be aggregated if working ports fail. If it is a static trunk group (non-LACP), the number of work ports must equal the total number of group member ports.
When you had setup the LACP aggregator, you will see relation information in here.
Having set up the aggregator setting with LACP disabled, you will see the local static trunk group information on the tab of Aggregator Information.
System Priority · Work ports




This page includes the following fields:
Group Key This is a read-only column field that displays the trunk group ID.
Port member This is a read-only column field that displays the members of this static trunk group.
Having set up the aggregator setting with LACP enabled, you will see the trunking group information between two switches on the tab of Aggregator Information.
LACP enabled



Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure the state activity for the members of the LACP trunk group. You can tick or cancel the checkbox beside the state label. When you remove the tick mark of the port and click Apply, the port state activity will change to Passive.


This page includes the following fields:
Active The port automatically sends LACP protocol packets.
The port does not automatically send LACP protocol packets, and responds only if it receives LACP protocol packets from the opposite device.
The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MAC address of the equipment sending the frame. The SMAC address is used by the switch to automatically update the MAC table with these dynamic MAC addresses. Dynamic entries are removed from the MAC table if no frames with the corresponding SMAC address have been seen after a configurable age time.
Entries in the MAC Table are shown on this page. The Dynamic MAC Table contains up to 8192 entries, and is sorted first by VLAN ID, then by MAC address. You can view all of the dynamic MAC addresses learned by the listed port.
Passive


NO The index of the MAC address entry.
MAC The MAC address of the entry.
PORT The ports that are members of the entry.
VID The VLAN ID of the entry.
Type Indicates whether the entry is a static or dynamic entry.
Click "Clear" to clear the dynamic MAC addresses information of the current port shown on the screen.
You can add a static MAC address that remains in the switch's address table regardless of whether the device is physically connected to the switch. This saves the switch from having to re-learn a device's MAC address when the disconnected or powered-off device is active on the network again. Via this interface, you can add / modify / delete a static MAC address.
Add the Static MAC Address
You can add static MAC address in the switch MAC table here.
MAC Table Entries


This page includes the following fields:
MAC Address Enter the MAC address of the port that should permanently forward traffic, regardless of the device network activity.
Port Num Pull down the selection menu to select the port number.
VLAN ID The VLAN ID for the entry.
By filtering MAC address, the switch can easily filter the pre-configured MAC address and become more secure. You can add and delete filtering MAC address.


This page includes the following fields:
MAC Address Enter the MAC address that you want to filter.
VLAN ID The VLAN ID for the entry.

The Internet Group Management Protocol (IGMP) lets host and routers share information about multicast groups memberships. IGMP snooping is a switch feature that monitors the exchange of IGMP messages and copies them to the CPU for feature processing. The overall purpose of IGMP Snooping is to limit the forwarding of multicast frames to only ports that are a member of the multicast group.
About the Internet Group Management Protocol (IGMP) Snooping
Computers and network devices that want to receive multicast transmissions need to inform nearby routers that they will become members of a multicast group. The Internet Group Management Protocol (IGMP) is used to communicate this information. IGMP is also used to periodically check the multicast group for members that are no longer active. In the case where there is more than one multicast router on a sub network, one router is elected as the 'queried'. This router then keeps track of the membership of the multicast groups that have active members. The information received from IGMP is then used to determine if multicast packets should be forwarded to a given sub network or not. The router can check, using IGMP, to see if there is at least one member of a multicast group on a given subnet work. If there are no members on a sub network, packets will not be forwarded to that sub network.





IGMP Versions 1 and 2
Multicast groups allow members to join or leave at any time. IGMP provides the method for members and multicast routers to communicate when joining or leaving a multicast group.
IGMP version 1 is defined in RFC 1112. It has a fixed packet size and no optional data.
The format of an IGMP packet is shown below:
0 8 16 31
Type Response Time Checksum
Group Address (all zeros if this is a query).
The IGMP Type codes are shown below:
0x11 Membership Query (if Group Address is 0.0.0.0).
0x11 Specific Group Membership Query (if Group Address is Present).
0x16 Membership Report (version 2).
0x17 Leave a Group (version 2).
0x12 Membership Report (version 1).
IGMP packets enable multicast routers to keep track of the membership of multicast groups, on their respective sub networks. The following outlines what is communicated between a multicast router and a multicast group member using IGMP.
A host sends an IGMP "report" to join a group.
A host will never send a report when it wants to leave a group (for version 1).
A host will send a "leave" report when it wants to leave a group (for version 2).
Multicast routers send IGMP queries (to the all-hosts group address: 224.0.0.1) periodically to see whether any group members exist on their sub networks. If there is no response from a particular group, the router assumes that there are no group members on the network.
IGMP Message Format · Octets · Type Meaning

The Time-to-Live (TTL) field of query messages is set to 1 so that the queries will not be forwarded to other sub networks.
IGMP version 2 introduces some enhancements such as a method to elect a multicast queried for each LAN, an explicit leave message, and query messages that are specific to a given group.
The states a computer will go through to join or to leave a multicast group are shown below:
Leave Group (Stop Timer) Leave Group Join Group (Send Report
(Start Timer) Report Received
(Stop Timer) Timer Expried
A router, or multicast-enabled switch, can periodically ask their hosts if they want to receive multicast traffic. If there is more than one router/switch on the LAN performing IP multicasting, one of these devices is elected "querier" and assumes the role of querying the LAN for group members. It then propagates the service requests on to any upstream multicast switch/router to ensure that it will continue to receive the multicast service.

The Switch support IP multicast, you can enable IGMP protocol on web management's switch setting advanced page, then the IGMP snooping information displays. IP multicast addresses range are from 224.0.0.0 through 239.255.255.255.

This page includes the following fields:
IGMP Protocol Enable or disable the IGMP protocol.
IGMP Fastleave Enable or disable Fast Leave on the port.
IGMP Querier Enable or disable the IGMP query function. The IGMP query information will be displayed in IGMP status section.
NOTE: Fast Leave: The Managed Switch can be configured to immediately delete a member port of a multicast service if a leave packet is received at that port and the fastleave function is enabled for the parent VLAN. This allows the Managed witch to remove a port from the multicast forwarding table without first having to send an IGMP group-specific query to that interface.

Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as multi-media, video, protocol- specific, time critical, and file-backup traffic.
QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your data and allows you to prioritize certain applications across your network. You can define exactly how you want the switch to treat selected applications and types of traffic.
You can use QoS on your system to:
The QoS page of the Switch contains three types of QoS mode - the CoS mode, TOS mode or Port-based mode can be selected. Both the three mode rely on predefined fields within the packet to determine the output queue.

QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems. When CoS/802.1p Tag Priority is applied, the Switch recognizes 802.1Q VLAN tag packets and extracts the VLAN tagged packets with User Priority value.
802.1Q Tag and 802.1p priority
User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits
2 bytes 2 bytes
Source Address VLAN TAG Ethernet
6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes
Set up the COS priority level. With the drop-down selection item of Priority Type above being selected as COS only/COS first, this control item will then be available to set the queuing policy for each port.
Priority Queue Service settings
QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In 802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.
The Switch supports Static Port Ingress priority and four queues. The screen in Figure 79 appears.


This page includes the following fields:
First Come First Service The sequence of packets sent is dependant on arrival order.
All High before Low The high priority packets are sent before low priority packets.
Select the preference given to packets in the switch's higher-priority queue. These options represent the number of higher priority packets sent before one lower priority packet is sent.
For example, 8 Highest : 4 SecHigh : 2 SecLow : 1 Lowest means that the switch sends 8 highest priority packets before sending 4 second high priority packet, before sending 2 second low priority packet, before sending 1 lowest priority packet.
802.1p priority [0-7] Set up the COS priority level 0-7—High, Middle, Low, Lowest.
Weighted Round Robin

Configure the priority level for each port. With the drop-down selection item of Priority Type above being selected as Port-based, this control item will then be available to set the queuing policy for each port.

This page includes the following fields:
Port Number: Indicates port 1 to port 26.
Port Priority: Each port has 8 priority levels—0-7 or Disable to be chosen. 7 is the highest priority.
TOS/DSCP priority is obtained through a 6-bit Type-of-Service (TOS) or Differentiated Service Code Point (DSCP) to 3-bit priority mapping.
The Type of Service (TOS) octet in the IPv4 header is divided into three parts; Precedence (3 bits), TOS (4 bits), and MBZ (1 bit). The Precedence bits indicate the importance of a packet, whereas the TOS bits indicate how the network should make tradeoffs between throughput, delay, reliability, and cost (as defined in RFC 1394). The MBZ bit (for "must be zero") is currently unused and is either set to zero or just ignored.
QoS PerPort Configuration

0 1 2 3 4 5 6 7
Pv4 Packet Header Type of Service Octet
The four TOS bits provide 15 different priority values, however only five values have a defined meaning.
DiffServ Code Point (DSCP) - is the traffic prioritization bits within an IP header that are encoded by certain applications and/or devices to indicate the level of service required by the packet across a network. DSCP are defined in RFC2597 for classifying traffic into different service classes. The Managed Switch extracts the codepoint value of the DS field from IPv4 packets and identifies the priority of the incoming IP packets based on the configured priority.
4 bit 4 bit 6 bit 2 bit
TAG
6 bytes 6 bytes 4 bytes 2 bytes 2 bytes 46-1517 bytes 4 bytes
The DSCP is six bits wide, allowing coding for up to 64 different forwarding behaviors. The DSCP retains backward compatibility with the three precedence bits so that non- DSCP compliant, TOS-enabled devices, will not conflict with the DSCP mapping. Based on network policies, different kinds of traffic can be marked for different kinds of forwarding.
The TOS/DSCP page provides fields for defining output queue to specific DSCP fields. When TCP/IP's TOS/DSCP mode is applied, the Managed Switch recognizes TCP/IP Differentiated Service Codepoint (DSCP) priority information from the DS-field defined in RFC2474.
Enable TOS/DSCP for traffic classification and then the DSCP to priority mapping column is configurable, as Figure 81 shows:


This page includes the following fields:
TOS/DSCP Enable / Disable internal traffic class ( 0-7) to map the corresponding IP DSCP value.
The values of the IP DSCP header field within the incoming packet.
Specify which 802.1p priority to map the corresponding IP DSCP.
The value is 0-7.
Set up IP TOS / DSCP mapping to 802.1p priority when receiving IPv4/IPv6 packets, the Managed Switch allows to by port configuring the QoS Status. This TOS/DSCP Port Configuration page is to configure the IP TOS/DSCP mapping on the port and display the current port status. The screen in Figure 82 appears.
Priority · TOS/DSCP Port Configuration


This page includes the following fields:
Port Number Indicates port 1 to port 26.
TOS/DSCP Status Enable / Disable TOS/DSCP map to 802.1p priority on specify port.
The Access Control List (ACL) is a concept in computer security used to enforce privilege separation. It is a means of determining the appropriate access rights to a given object depending on certain aspects of the process that is making the request, principally the process's user identifier. Access Control List (ACL) is a mechanism that implements access control for a system resource by listing the identities of the system entities that are permitted or denied to access the resource. The screen in following figure appears.
Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be used to block packets by maintaining a table of packet fragments indexed by source and destination IP address, protocol, and so on.
Packet Type/Bindings can be selected to ACL for Ipv4 or Non-Ipv4.


This page includes the following fields:
Group ID 1 - 247 (max. 247 ACL group).
Action Permit / Deny.
VLAN Any / VID.
Packet Type IPv4 / Non-IPv4 / Binding

Src IP Address Set this field if Packet Type is IPv4, else ignore.
Any / IP and Mask
* is represent a digit from 0-9,
*** is range from 0 to 255
Dst IP Address Set this field if Packet Type is IPv4, else ignore.
Any / IP and Mask
Any: Any IP address.
IP : A certain IP address.
* is represent a digit from 0-9,
*** is range from 0 to 255
IP Fragment Set this field if Packet Type is IPv4, else ignore.
Uncheck: Not check IP fragment field.
Check: Check IP fragment field.
L4 Protocol Set this field if Packet Type is IPv4, else ignore.
Any / ICMP(1) / IGMP(2) / TCP(6) / UDP(17)
Protocol Set this field if Packet Type is IPv4, else ignore.
If protocol not find in L4 Protocol field, you can direct assign number.
TCP Set this field if Packet Type is IPv4, else ignore.
Any / FTP(21) / HTTP(80)
Port Set this field if Packet Type is IPv4, else ignore.
If TCP port not find in TCP field, you can direct assign number.
UDP Set this field if Packet Type is IPv4, else ignore.
Any / DHCP(67) / TFTP(69) / NetBios(137)

Port Set this field if Packet Type is IPv4, else ignore.
If UDP port not find in UDP field, you can direct assign number.
Port Id Source port id, from 1-26, 0 means don’t care. 0
Current List You create ACL and Binding groups.
In Packet Type/Binding box should select Non-IPv4
Group ID 1 - 247 (max. 247 ACL group)
Action Permit / Deny.
VLAN Any / VID.
Packet Type IPv4 / Non-IPv4 / Binding
Set this field if Packet Type is Non-IPv4, else ignore.)
Any / ARP(0x0806) / IPX(0x8137)
Type Set this field if Packet Type is Non-IPv4, else ignore.)
If ether type not find in Ether Type field, you can direct assign number.
Current List You create ACL and Binding groups.

Let a device that has specific IP address and MAC address use the network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match.
Use binding function; we should enable it first in following page.
In Packet Type/Binding box should select Binding.
Group ID 1 - 247 (max. 247 ACL group)
Action Permit / Deny.
VLAN Any / VID.
Packet Type IPv4 / Non-IPv4 / Binding
MAC Address **:**:**:**:**:**
00:11:22:33:44:55
* is represent a digit from 0-9 and A-F,
*** is range from 0 to FF.
IP Address ***.***.***.***
0.0.0.0
* is represent a digit from 0-9,
*** is range from 0 to 255.
Port Id Source port id, from 1-26. 1
Current List You create ACL and Binding groups.

MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table are the result of first-come-first-save policy. Once a MAC address is stored in the MAC address table, it stays in until it is aged out. When an "opening" is available, the switch stored the first new MAC address it sees in that opening. All packets from MAC addresses not in the MAC address table should be blocked.
The Layer 2 MAC Limit function can be per-port configured for security management purposes. When the port is in MAC Limit mode, the port will be "locked" without permission of address learning. Only the incoming packets with Source MAC already existing in the address table can be forwarded normally. User can disable the port from learning any new MAC addresses.

This page includes the following fields:
MAC Limit Enable or disable MAC limit function for the Managed Switch.
Port Number Indicate port 1 to port 26.
Limit The maximum number of per-port MAC addresses to be learned (1-64, 0 to disable this port's MAC limit function).

This table displays current MAC Limit status of each port.

This page includes the following fields:
Port Number Indicates port 1 to port 26.
Limit Display the current MAC Limit configuration and status of each port.

802.1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority, like the user name and password that are verified by an authentication server (such as RADIUS server).
The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server authenticates each client connected to a switch port before making available any services offered by the switch or the LAN.
Until the client is authenticated, 802.1X access control allows only Extensible Authentication Protocol over LAN (EAPOL) traffic through the port to which the client is connected. After authentication is successful, normal traffic can pass through the port.
This section includes this conceptual information:
With 802.1X port-based authentication, the devices in the network have specific roles as shown below.


Client-the device (workstation) that requests access to the LAN and switch services and responds to requests from the switch. The workstation must be running 802.1X- compliant client software such as that offered in the Microsoft Windows XP operating system. (The client is the supplicant in the IEEE 802.1X specification.)

The switch or the client can initiate authentication. If you enable authentication on a port by using the dot1x port-control auto interface configuration command, the switch must initiate authentication when it determines that the port link state transitions from down to up. It then sends an EAP-request/identity frame to the client to request its identity (typically, the switch sends an initial identity/request frame followed by one or more requests for authentication information). Upon receipt of the frame, the client responds with an EAP-response/identity frame.
However, if during bootup, the client does not receive an EAP-request/identity frame from the switch, the client can initiate authentication by sending an EAPOL-start frame, which prompts the switch to request the client's identity.
NOTE: If 802.1X is not enabled or supported on the network access device, any EAPOL frames from the client are dropped. If the client does not receive an EAP- request/identity frame after three attempts to start authentication, the client transmits frames as if the port is in the authorized state. A port in the authorized state effectively means that the client has been successfully authenticated.
When the client supplies its identity, the switch begins its role as the intermediary, passing EAP frames between the client and the authentication server until authentication succeeds or fails. If the authentication succeeds, the switch port becomes authorized.
The specific exchange of EAP frames depends on the authentication method being used. "Figure 87" shows a message exchange initiated by the client using the One- Time-Password (OTP) authentication method with a RADIUS server.


The switch port state determines whether or not the client is granted access to the network. The port starts in the unauthorized state. While in this state, the port disallows all ingress and egress traffic except for 802.1X protocol packets. When a client is successfully authenticated, the port transitions to the authorized state, allowing all traffic for the client to flow normally.
If a client that does not support 802.1X is connected to an unauthorized 802.1X port, the switch requests the client's identity. In this situation, the client does not respond to the request, the port remains in the unauthorized state, and the client is not granted access to the network.
In contrast, when an 802.1X-enabled client connects to a port that is not running the 802.1X protocol, the client initiates the authentication process by sending the EAPOL- start frame. When no response is received, the client sends the request for a fixed number of times. Because no response is received, the client begins sending frames as if the port is in the authorized state
If the client is successfully authenticated (receives an Accept frame from the authentication server), the port state changes to authorized, and all frames from the authenticated client are allowed through the port. If the authentication fails, the port remains in the unauthorized state, but authentication can be retried. If the

authentication server cannot be reached, the switch can retransmit the request. If no response is received from the server after the specified number of attempts, authentication fails, and network access is not granted.
When a client logs off, it sends an EAPOL-logoff message, causing the switch port to transition to the unauthorized state.
If the link state of a port transitions from up to down, or if an EAPOL-logoff frame is received, the port returns to the unauthorized state.
802.1x makes use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide a means of authenticating and authorizing devices attached to a LAN port that has point-to-point connection characteristics, and of preventing access to that port in cases in which the authentication and authorization process fails.
To enable 802.1x, from System \ System Information \ Misc Config then you still to fill in the authentication server information:


After enabling the IEEE 802.1X function, you can configure the parameters of this function.

This page includes the following fields:
IEEE 802.1x Protocol: Enable or disable 802.1x protocol.
Radius Server IP: Assign the RADIUS Server IP address.
Server Port: Set the UDP destination port for authentication requests to the specified RADIUS Server.
Accounting Port: Set the UDP destination port for accounting requests to the specified RADIUS Server.
Set an encryption key for using during authentication sessions with the specified RADIUS server. This key must match the encryption key used on the RADIUS Server.
Shared Key:
NAS, Identifier: Set the identifier for the RADIUS client.
In this page, you can select the specific port and configure the authorization state. The state provides No Authorization, Force Authorized, Force unauthorized, and Authorize.


This page includes the following fields:
FU (Force Unauthorized) The specified port is required to be held in the unauthorized state.
FA (Force Authorized) The specified port is required to be held in the authorized state.
The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server.
No The specified port works without complying with 802.1x protocol.
Authorize

In this page, you can change the default configuration for the 802.1x standard:

This page includes the following fields:
Used to define periods of time during which it will not attempt to acquire a supplicant.
Quiet Period:
Default time is 60 seconds.
Set the period the port waits for retransmit next EAPOL PDU during an authentication session.
TX Period:
Default value is 30 seconds.
Set the period of time the switch waits for a supplicant response to an EAP request.
Supplicant Timeout:
Default value is 30 seconds.
Set the period of time the switch waits for a server response to an authentication request.
Server Timeout:
Default value is 30 seconds.
Set the number of authentication that must time-out before authentication fails and the authentication session ends.
Max Requests:
Default value is 2 times.
Set the period of time which clients connected must be re- authenticated.
Reauth period:
Default value is 3600 seconds.

Providing up to 24 PoE, in-line power interface, the GE-DS-82-PoEPoE Switch can easily build a power central-controlled IP phone system, IP Camera system, AP group for the enterprise. For instance, 24 camera / AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the office. Without the power-socket limitation, the PoE Switch makes the installation of cameras or WLAN AP more easily and efficiently.
Voice over IP phones
Enterprise can install POE VoIP Phone, ATA and other Ethernet/non- Ethernet end-devices to the central where UPS is installed for un-interrupt power system and power control system.
Wireless LAN Access Points
Museum, Sightseeing, Airport, Hotel, Campus, Factory, Warehouse can install the Access Point any where with no hesitation
Enterprise, Museum, Campus, Hospital, Bank, can install IP Camera without limits of install location – no need electrician to install AC sockets.

PoE Splitter split the PoE 48V DC over the Ethernet cable into 5/9/12V DC power output. It frees the device deployment from restrictions due to power outlet locations, which eliminate the costs for additional AC wiring and reduces the installation time.
In a power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN infrastructure to powered devices (PDs), which are connected to ports. Under some conditions, the total output power required by PDs can exceed the maximum available power provided by the PSU. The system may a prior be planed with a PSU capable of supplying less power than the total potential power consumption of all the PoE ports in the system. In order to maintain the majority of ports active, power management is implemented.

The PSU input power consumption is monitored by measuring the voltage and current. The input power consumption is equal to the system's aggregated power consumption. The power management concept allows all ports to be active and activates additional ports, as long as the aggregated power of the system is lower than the power level at which additional PDs cannot be connected. When this value is exceeded, ports will be deactivated, according to user-defined priorities. The power budget is managed according to the following user-definable parameters: maximum available power, ports priority, the maximum allowable power per port.
The Over Temperature Protection of the PoE Switch offers a safety and stable PoE operating by limit the output power according to detected temperature to prevent destructive breakdown due to un-expected overheating.
This section provides PoE (Power over Ethernet) Configuration and PoE output status of the PoE Switch, the screen in Figure 92 appears.


This page includes the following fields:
PoE PSU Status PoE PSU Status shows status of power supply for PoE output.
PoE Temperature Unit 1 Display the current operating temperature of PoE chip unit 1.
The unit 1 is in charge of PoE Port-1-Port-12
PoE Temperature Unit 2 Display the current operating temperature of PoE chip unit 2.
The unit 1 is in charge of PoE Port-13-Port-24
Enable / Disable over temperature protection.
When the PoE temperature unit 1 / unit2 over 70 degree C then PoE power budget will be changed by 3 segments as following.
Over 70 Degree C power budget 180 Watts
Over 73 Degree C power budget 170 Watts
Over 76 Degree C power budget 160 Watts
Power limit mode Allow you to configure the power limit mode of Web Smart Device. You can choose :
Port Priority Deliver PoE power by port priority setting
Total Limit. Set limit value of the total POE port provided power to the PDs.
Power Allocation Show the total watts usage of PoE Switch.
PoE Function Can enable or disable the PoE function.
Priority Set port priority for the POE power management
It can choose the “port priority”, value is :
High priority is “Critical”.
Device class Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes. A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by Table 4.1.
Current(mA) It shows the PoE device current Amp.
Consumption [W] It shows the PoE device current watt.

Power Limit It can limit the port PoE supply watts.
Per port maximum value must less 15.4, total ports values must less than the Power Reservation value.
Once power overload detected, the port will auto shut down and keep on detection mode until PD’s power consumption lower than the power limit value.
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is to provide information about the maximum power required by the PD during operation. Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes.
A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by the table below.
Class Usage Range of maximum power used by the PD
0 Default 0.44 to 12.95 Watts
1 Optional 0.44 to 3.84 Watts
2 Optional 3.84 to 6.49 Watts
3 Optional 6.49 to 12.95 Watts
4 Not Allowed Reserved for Future Use
PD Classifications

The Relay Agent Information option (Option82) is inserted by the DHCP relay agent when forwarding client-originated DHCP packets to a DHCP server (RFC 3046). Servers recognizing the Relay Agent Information option may use the information to implement IP address or other parameter assignment policies.
The DHCP Relay can forward the DHCP broadcast packets to a DHCP server in a different subnet (RFC 1542). So DHCP server can provide IP addresses to clients spanning multiple subnets instead of deploying a DHCP server on every subnet.
Configuring DHCP Relay & Option82
To configure DHCP Option82
To configure DHCP Relay


This page includes the following fields:
DHCP Option 82 Enable global option82 function
DHCP Relay Enable global Relay function
DHCP Option 82 Router Port
DCHP Opt.82 Port Identify Port-1 to Port-10 to configure DHCP option 82
Option Enable port option82 function on selected port.
Relay IP Type the IP addresses of the DHCP "Relay IP".
Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on the local broadcast domain. LLDP is a Layer 2 protocol that uses periodic broadcasts to advertise information about the sending device. Advertised information is represented in Type Length Value (TLV) format according to the IEEE 802.1ab standard, and can include details such as device identification, capabilities and configuration settings. LLDP also defines how to store and maintain information gathered about the neighboring network nodes it discovers.

Use this page to change LLDP parameters.

This page includes the following fields:
LLDP Status Enable/Disable LLDP.
LLDP hello time You can change LLDP hello time value. The time interval between the transmission LLDP info packets. Value range is from 5 to 32768. Default value is 30.
LLDP hold time You can change LLDP hold time value. (The hold time * the hello time) is the TTL time in the LLDP info packets. Value range is from 2 to 10. Default value is 4.
This page allows the user to inspect and configure the current LLDP port settings. The LLDP Configuration screen in Figure 95 appears.
LLDP Configuration · PerPort Configuration


This page includes the following fields:
LLDP Status Enable/Disable LLDP.
LLDP hello time You can change LLDP hello time value. The time interval between the transmission LLDP info packets. Value range is from 5 to 32768. Default value is 30.
LLDP hold time You can change LLDP hold time value. (The hold time * the hello time) is the TTL time in the LLDP info packets. Value range is from 2 to 10. Default value is 4.
Port Status You can change LLDP port status to Tx_only/Rx_only/Tx_and_Rx/Disable. Tx_only: LLDP transmit the packet of the port only. Rx_only: LLDP receive the packet of the port only. Tx_and_Rx: LLDP transmit and receive the packets of the port. Disable: LLDP do not transmit and receive the packets of the port.

Login in to the Console Interface
To configure the system via console mode, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type serial (console) port of the Managed Switch. The console port of the Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of Null Modem.
Please refer to the Administration Console section on page 28 to get more information about how to connect to the console interface of GE-DS-82-PoE with HyperTerminal on Microsoft Windows platform.
Once the terminal has connected to the device, power on the GE-DS-82-PoE, the terminal will display that it is running testing procedures.
Then, the following message asks the login password. The factory default password as following and the login screen in Figure 96 appears.


Username Max: 6, Min: 1 characters.
Password Max: 6, Min: 1 characters.
Only enter commands in lowercase letters in the console interface.

The GE-DS-82-PoEManaged Switch is shipped with default IP address as following.
To check the current IP address or modify a new IP address for the Switch, please use the procedures as follow:
Show the current IP address


Switch(config)# ip address 192.168.1.100 255.255.255.0
Switch(config)# ip default-gateway 192.168.1.254
The previous command would apply the follow settings for the Switch.
If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Managed Switch through the new IP address.
Configure IP address

You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.
The following table lists the CLI commands and description.
Modes Access Method Prompt Exit Method About This Model
The user commands available at the user level are a subset of those available at the privileged level.
User EXEC Begin a session with your switch. switch> Enter logout or quit.
Use this mode to:
The privileged command is the advanced mode.
Enter the enable command while in User EXEC mode.
switch# Enter disable to exit.
Use this mode to
Use this mode to configure those parameters that are going to be applied to your switch.
Enter the configure command while in privileged EXEC mode.
To exit to privileged EXEC mode, enter exit or end
Privileged EXEC · Global Configuration · switch (config)#


Operation Notice
To enter the "configuration" mode, you need to be in the privileged mode, and then types in the command configure:
Switch# configure · Switch (config) #

<Ctrl>-B ; ← Moves the cursor back one character.
<Ctrl>-D Deletes the character at the cursor.
<Ctrl>-E Jumps to the end of the current command line.
<Ctrl>-F ; → Moves the cursor forward one character.
<Ctrl>-K Deletes from the cursor to the end of the command line.
<Ctrl>-N ; ↓ Enters the next command line in the command history.
<Ctrl>-P ; ↑ Enters the previous command line in the command history.
<Ctrl>-U Deletes from the cursor to the beginning of the command line.
<Ctrl> -W Deletes the last word typed.
<Esc> B Moves the cursor backward one word.
<Esc> D Deletes from the cursor to the end of the word.
<Esc> F Moves the cursor forward one word.
<Backspace> Delete the character before the cursor.
<Del> Delete the character at the cursor.
The following generic function keys provide functions in all of the menus:
You may enter ? at any command mode, and the CLI will return all possible commands at that point, along with some description of the command.
show running-config Display the running configuration of the switch.
Backup the switch configurations.
erase startup-config Reset to default factory settings at next boot time.
clear arp specifies the IP address to be cleared. If no IP address is entered, the entire ARP cache is cleared.
show arp Show the IP ARP translation table.
Ping Send ICMP ECHO_REQUEST to network hosts.
Parameters: specifies the number of repetitions. If not entered, it will continue to ping until you press -C to stop.
Key Function · Command Description · copy running-config startup- config

Description:
Turn the port state on or off.
Syntax:
port state []
Parameters:
<port-list> specifies the ports to be turn on or off. If not entered, all ports are turn on or off.
Description:
Set port negotiation.
Syntax:
port nego []
Parameters:
<port-list> specifies the ports to be set.If not entered, all ports are set.
Description:
Set port speed (in mbps) and duplex.
Syntax:
port speed []
Parameters:
<port-list> specifies the ports to be set. If not entered, all ports are set.
port state · port nego · port speed

Description:
Enable or disable port flow control.
Syntax:
port flow []
Parameters:
The first enables or disables flow control in full duplex mode.
The second enables or disables flow control in half duplex mode.
specifies the ports to be set. If not entered, all ports are set.
Description:
Set port effective ingress or egress rate.
Syntax:
port rate []
Parameters:
specifies the ingress or egress rate.
specifies the ports to be set. If not entered, all ports are set.
Description:
Set port priority.
Syntax:
port priority []
Parameters:
specifies the ports to be set. If not entered, all ports are set.
port flow · port rate · port priority

Description:
Set port jumbo frame. When port jumbo frame is enable, the port forward jumbo frame packet
Syntax:
port jumboframe []
Parameters:
specifies the ports to be set. If not entered, all ports are set.
Description:
Show port status, including port State, Link, Trunking, VLAN, Negotiation, Speed, Duplex, Flow control, Rate control ,Priority, Security, BSF control.
Switch(config)# show port status

Description:
Show port statistics, including TxGoodPkt, TxBadPkt, RxGoodPkt, RxBadPkt, TxAbort, Collision, and DropPkt.
Parameters:
specifies the port to be shown.
Switch(config)# show port statistics


21 | off | 1
22 | off | 1
25 | off | 1
26 | off | 1
Trk1 | off | 1
Trunk allows the switch to combine ports so that they function like a single high- speed link. It can be used to increase the bandwidth to some devices to provide a high-speed link. For example, trunk is useful when making connections between switches or connecting servers to the switch. Trunk can also provide a redundant link for fault tolerance. If one link in the trunk failed, the switch can balance the traffic among the remaining links.
All ports in the same trunk group will be treated as a single port. If a trunk group exists, the ports belonging to that trunk will be replaced by "TRUNK #" in the VLAN configuration screen. The following example configures port 25-26 as "TRUNK 1."
Description:
Show trunking information.
Group ID | LACP | Ports | LACP Active
1 | Yes | 23,24 | 23,24
show trunks · Switch(config)# show trunk · + + +

Description:
Add a new trunk group.
Syntax:
trunk add <trunk-id> <lacp | no-lacp> <port-list> <active-port-list>
Parameters:
<trunk-id> specifies the trunk group to be added.
Description:
Specifies the added trunk group to be LACP enabled.
Syntax:
no-lacp specifies the added trunk group to be LACP disabled.
Parameters:
<port-list> specifies the ports to be set.
<active-port-list> specifies the ports to be set to LACP active.
Description:
Delete an existing trunk group.
Syntax:
Parameters:
<trunk-id> specifies the trunk group to be deleted
Description:
Enable/disable LACP.

Description:
Set LACP system priority.
Syntax:
lacp system-priority <1..65535>
Parameters:
<1..65535> specifies the LACP system priority.
Description:
Set LACP system priority to the default value 32768.
Description:
Show LACP enable/disable status and system priority.
Description:
Show LACP information.
Switch(config)# show lacp status
LACP is enabled.
Description:
Show LACP aggregator information.
Syntax:
show lacp agg <trunk-id>
Parameters:
<trunk-id> specifies the trunk group to be shown.

Description:
Show LACP information by port.
Syntax:
show lacp port <port-id>
Parameters:
<port-id> specifies the port to be shown.
A Virtual LAN (VLAN) is a logical network group that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN within a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still plugged into the same switch physically. A station can belong to more than one VLAN group. VLAN prevents users from accessing network resources of another on the same LAN, thus the users can not see the hard disks and printers of another user in the same building. VLAN can also increase the network performance by reducing the broadcast traffic and enhance the security of the network by isolating groups.
The GE-DS-82-PoEsupports two types of VLANs:
Only one of the two VLAN types can be enabled at one time.
Port-based VLANs are VLANs where the packet forwarding decision is made based on the destination MAC address and its associated port. You must define the outgoing ports allowed for each port when you use port-based VLANs. In port-based VLANs, the packets received from one port can only be sent to the ports which are configured to the same VLAN. As shown in the following figure, the switch administrator configured port 1-2 as VLAN 1 and port 3-4 as VLAN 2. The packets received from port 1 can only be forwarded to port 2. The packets received from port
show lacp port

2 can only be forwarded to port 1. That means the computer A can send packets to computer B, and vice versa. The same situation also occurred in VLAN 2. The computer C and D can communicate with each other. However, the computers in VLAN 1 can not see the computers in VLAN 2 since they belonged to different VLANs.
IEEE 802.1Q (tag) -based VLANs enable the Ethernet functionality to propagate tagged packets across the bridges and provides a uniform way for creating VLAN within a network then span across the network. For egress packet, you can choose to tag it or not with the associated VLAN ID of this port. For ingress packet, you can forward this packet to a specific port as long as it is also in the same VLAN group.
The 802.1Q VLAN works by using a tag added to the Ethernet packets. The tag contains a VLAN Identifier (VID) which belongs to a specific VLAN group. And ports can belong to more than one VLAN.
The difference between a port-based VLAN and a tag-based VLAN is that the tag- based VLAN truly divided the network into several logically connected LANs. Packets rambling around the switches can be forwarded more intelligently. In the figure shown below, by identifying the tag, broadcast packets coming from computer A in VLAN1 at sw1 can be forwarded directly to VLAN1.
However, the switch could not be so smart in the port-based VLAN mechanism. Broadcast packets will also be forwarded to port 4 of sw2. It means the port-based VLAN can not operate a logical VLAN group among switches.
The GE-DS-82-PoEsupports both Port-based VLAN and Tag-based (802.1Q) VLAN modes. The default configuration is tag-based (802.1Q) VLAN. In the 802.1Q VLAN, initially, all ports on the switch belong to default VLAN, VID is 1.
Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored.
Description:
Display the current VLAN mode.
show vlan mode

Description:
Change VLAN mode.
Syntax:
Parameters:
(disabled | port-based | dot1q) specifies the VLAN mode.
When a packet was received on a port, you can govern the switch to drop it or not if it is an untagged packet. Furthermore, if the received packet is tagged but not belonging to the same VALN group of the receiving port, you can also control the switch to forward or drop the packet. The example below configures the switch to drop the packets not belonging to the same VLAN group and forward the packets not containing VLAN tags.
Description:
Display the current VLAN mode.
Description:
Change VLAN mode.
Syntax:
Parameters:
(disabled | port-based | dot1q) specifies the VLAN mode.

Description:
Add or edit VLAN entry.
Syntax:
vlan add <1-4094> NAME (cpu-port|no-cpu-port) LIST [LIST]
Parameters:
<1-4094> specifies the VLAN id or Group id (if port based VLAN mode)
NAME specifies the VLAN group name.
(cpu-port|no-cpu-port) specifies the CPU port belong this VLAN group.
LIST specifies the ports to be set to VLAN members.
[LIST] specifies the ports to be set to tagged members. If not entered, all members set to untagged.
e.g.. switch(config)# vlan add 1 vlan1 cpu-port 1-4
This VLAN entry has four members (from port1 to port4) and all members are untagged.
Description:
Delete VLAN entry.
Syntax:
Parameters:
<1-4094> specifies the VLAN id or group id (if port based VLAN).
e.g. no vlan 1
vlan mode · no vlan · no vlan <1-4094>

Description:
Show VLAN entry information.
Syntax:
Parameters:
specifies the VLAN id, null means all valid entries.
e.g.
show vlan · show vlan [<1-4094>]

Switch(config)# show vlan 1

Description:
Show static VLAN entry information.
Description:
Show port default VLAN id.
Syntax:
show vlan pvid [LIST]
Parameters:
[LIST] specifies the ports to be showed. If not entered, all port’s PVID will be showed.
e.g.
show vlan static · show vlan pvid


Description:
Set ingress filter rules.
Syntax:
vlan filter (enable | disable) (enable | disable) LIST
Parameters:
(enable | disable) specifies the non-members packet will be forwarded or not. If set enable, forward only packets with VID matching this port's configured VID.
(enable | disable) specifies the untagged frame will be dropped or not. If set enable, drop untagged frame.
Description:
Show VLAN filter setting.
Syntax:
show vlan filter [LIST]
Parameters:
[LIST] specifies the ports to be showed. If not entered, all ports’ filter rules will be shown.
vlan filter · show vlan filter

Switch(config)# show vlan filter
Port | Rule 1 | Rule 2
Port1 | Drop | Forward
Port2 | Drop | Forward
Port3 | Drop | Forward
Port4 | Drop | Forward
Port5 | Drop | Forward
Port6 | Drop | Forward
Port7 | Drop | Forward
Port8 | Drop | Forward
Port9 | Drop | Forward
Port10 | Drop | Forward
Port11 | Drop | Forward
Port12 | Drop | Forward
Port13 | Drop | Forward
Port14 | Drop | Forward
Port15 | Drop | Forward
Port16 | Drop | Forward
Port17 | Drop | Forward
Port18 | Drop | Forward
Port19 | Drop | Forward
Port20 | Drop | Forward
Port21 | Drop | Forward
Port22 | Drop | Forward
Port25 | Drop | Forward
Port26 | Drop | Forward
Trk1 | Drop | Forward
Filter (nonmbr) (untag) · + + · --More--

Description:
Set MAC address age-out time.
Syntax:
[no] mac-age-time Enable or disable MAC address age-out.
mac-age-time
Parameters:
specifies the MAC address age-out time. Must be divisible by 6. Type the number of seconds that an inactive MAC address remains in the switch’s address table.
Description:
Show MAC address age-out time.
Description:
Set broadcast storm filter mode to off, 1/2, 1/4, 1/8, 1/16
Syntax:
broadcast mode
no mac-age-time · show mac-age-time · broadcast

Description:
Select the Broadcast storm filter packet type:
Syntax:
broadcast select
Description:
Syntax:
Collision-Retry < off | 16 | 32 | 48 >
Parameters:
16\32\48 – In Half-Duplex, collision-retry maximum is 16\32\48 times and packet will be dropped if collisions still happen
Disable – In Half-Duplex, if collision occurs, will retry forever (Default).
broadcast select · Collision-Retry · Collision-Retry setting

Description:
Set switch name.
Syntax:
hostname
Parameters:
specifies the switch name. If you would like to have spaces within the name, use quotes (“”) around the name.
Reset the switch name to factory default setting.
Description:
Set or remove username and password for manager or operator.
Syntax:
[no] password
Parameters:
The manager username and password is also used by the web UI.
hostname · no hostname · [no] password

User can configure the IP setting and fill in the new value.
Description:
Set IP address and subnet mask.
Syntax:
ip address
Description:
Set the default gateway IP address.
Syntax:
ip default-gateway
Description:
Show IP address, subnet mask, and the default gateway.
Description:
Show basic information, including system info, MAC address, and versions.

Description:
Set switch as dhcp client, it can get ip from dhcp server.
Description:
Show dhcp enable/disable.
Description:
Reboot (warm-start) the switch.
Description:
Reset configurations to default factory settings at next boot time.

Description:
Download firmware from TFTP server.
Syntax:
copy tftp firmware
Parameters:
specifies the IP address of the TFTP server.
specifies the file to be downloaded from the TFTP server.
copy tftp <running – config | flash>
Description:
Retrieve configuration from the TFTP server. If the remote file is the text file of CLI commands, use the keyword running-config.
If the remote file is the configuration flash image of the switch instead, use the keyword flash.
Syntax:
copy tftp
Parameters:
specifies the IP address of the TFTP server.
specifies the file to be downloaded from the TFTP server.
copy tftp firmware

copy <running – config | flash> tftp
Description:
Send configuration to the TFTP server. If you want to save the configuration in a text file of CLI commands, use the keywordrunning-config. If you want to save the configuration flash image instead, use the keyword flash.
Syntax:
copy tftp
Parameters:
specifies the IP address of the TFTP server.

MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table is the result of first-come-first-save policy. Once a MAC address is stored in the MAC address table, it stays in until it is aged out. When an “opening” is available, the switch stored the first new MAC address it sees in that opening. All packets from MAC addresses not in the MAC address table should be blocked.
User can configure the MAC limit setting and fill in the new value.
Description:
Enable MAC limit.
Description:
Disable MAC limit.
Description:
Set port MAC limit value, 0 to turn off MAC limit of port.
Syntax:
Description:
Show MAC limit information, including MAC limit enable/disable, per-port MAC limit setting.

Port monitoring is a feature to redirect the traffic occurred on every port to a designated monitoring port on the switch. With this feature, the network administrator can monitor and analyze the traffic on the entire LAN segment. In the Managed Switch, you can specify one port to be the monitored ports and any single port to be the monitoring port. You also can specify the direction of the traffic that you want to monitor. After properly configured, packets with the specified direction from the monitored ports are forwarded to the monitoring port.
Description:
Set port monitoring information. (RX only|TX only|both RX and TX)
Syntax:
mirror-port
Parameters:
rx specifies monitoring rx only.
tx specifies monitoring tx only.
both specifies monitoring both rx and tx.
specifies the analysis port ID. This port receives traffic from all monitored ports.
specifies the monitored port list.
Description:
Show port monitoring information.
mirror-port · show mirror-port

There are four transmission queues with different priorities in the Managed Switch: Highest, SecHigh, SecLow and Lowest. The Managed Switch will take packets from the four queues according to its QoS mode setting. If the QoS mode was set to "Disable", the Managed Switch will not perform QoS on its switched network. If the QoS mode was set to "High Empty Then Low", the Managed Switch will never exhaust packets from a queue until the queues with higher priorities are empty. If the QoS mode was set to "weight ratio", the Managed Switch will exhaust packets from the queues according to the ratio. The default value of QoS mode is "weight 8:4:2:1." That means the switch will first exhaust 8 packets from the queue with highest priority, and then exhaust 4 packets from the queue with second high priority, and so on.
When the switch received a packet, the switch has to decide which queue to put the received packet into. In the Managed Switch, it will put received packets into queues according to the settings of "802.1p Priority" and "Static Port Ingress Priority." When the received packet is an 802.1p tagged packet, the switch will put the packet into a queue according to the 802.1p Priority setting.
Otherwise, the switch will put the packet into a queue according the setting of Static Port Ingress Priority.
QoS mode:

priority packets sent before one lower priority packet is sent. For example, 8 Highest:4 second-high means that the switch sends 8 highest-priority packets before sending 4 second-high priority packets.
Description:
Set 802.1p priority.
Syntax:
qos priority <first-come-first-service | all-high-before-low |weighted-round-robin>
Parameters:
[][][] []
e.g. qos priority weighted-round-robin 8,4,2,1.
Description:
Set priority levels to highest, second-high, second-low and lowest.
Syntax:
qos level < highest | second-high | second-low | lowest >
Parameters:
specifies the priority levels to be high or low.
between 1 and 7.
e.g. qos level highest 7
e.g. qos level lowest 4
qos priority · qos level · Level must be

Description:
Show QoS configurations, including802.1p priority, priority level.
e.g.
QoS configurations:
802.1p priority[0-7]:
Lowest Lowest SecLow SecLow SecHigh SecHigh Highest Highest
Description:
Set port priority.
Syntax:
port priority <disable | [0-7]> []
Parameters:
specifies the ports to be set. If not entered, all ports are set.
e.g. port priority disable 1-5
show qos · Switch(config)# show qos · port priority

Description:
Clear all dynamic MAC address table entries.
Description:
Set static unicast or multicast MAC address. If multicast MAC address (address beginning with 01:00:5E) is supplied, the last parameter must be port-list. Otherwise, it must be port-id.
Syntax:
mac-address-table static
no mac-address-table static mac-addr
Description:
Delete static unicast or multicast MAC address table entries.
Syntax:
no mac-address-table static mac-addr
Description:
Display MAC address table entries.
MAC Address | VLAN | Type | Source
00:08:B6:00:06:90 | 1 | Dynamic | 25
00:40:63:00:65:30 | 1 | Dynamic | Trk1
00:03:63:F7:80:7F | 1 | Dynamic | 25

Description:
Display static MAC address table entries.
Description:
Display multicast-related MAC address table.
Description:
Set static unicast or multicast MAC address in secondary MAC address table. If multicast MAC address (address beginning with 01:00:5E) is supplied, the last parameter must be port-list. Otherwise, it must be port-id.
Syntax:
smac-address-table static
Description:
Display secondary MAC address table entries.
Description:
Display multicast-related secondary MAC address table.
Description:
Set MAC address filter. The packets will be filtered if both of the destination MAC address and the VLAN tag matches the filter entry. If the packet does not have a VLAN tag, then it matches an entry with VLAN ID 1.
Syntax:
[no] filter <mac-addr> <vlan-id>

Description:
Display filter MAC address table.
Description:
Enable or disable spanning-tree.
Description:
Set spanning tree forward delay used, in seconds.
Syntax:
spanning-tree forward-delay <4-30>
Parameters:
specifies the forward delay, in seconds. Default value is 15.
Description:
Set spanning tree hello time, in seconds.
Syntax:
Parameters:
specifies the hello time, in seconds. Default value is 2.
2*(hello-time + 1)

Description:
Set spanning tree maximum age, in seconds.
Syntax:
Parameters:
specifies the maximum age, in seconds. Default value is 20.
2*(hello-time + 1)
Description:
Set spanning tree bridge priority.
Syntax:
Parameters:
specifies the bridge priority. The value must be in steps of 4096.
Description:
Set spanning tree port path cost.
Syntax:
spanning-tree port path-cost <1-200000000> [<port-list>]
Parameters:
specifies port path cost.
specifies the ports to be set. Null means all ports.

Description:
Set spanning tree port priority.
Syntax:
spanning-tree port priority <0-240> [<port-list>]
Parameters:
specifies the port priority. The value must be in steps of 16.
specifies the ports to be set. Null means all ports.
Description:
Show spanning-tree information.
Description:
Show spanning tree per port information.
Syntax:
show spanning-tree port [<port-list>]
Parameters:
specifies the port to be shown. Null means all ports.
The remaining commands in this section are only for system with RSTP (rapid spanning tree, 802.1w) capability:
Description:
Enable or disable spanning tree debugging information.
show spanning-tree · show spanning-tree port · spanning-tree debug

Description:
Change spanning tree protocol version.
Syntax:
spanning-tree protocol-version <stp | rstp>
Parameters:
stp specifies the original spanning tree protocol (STP,802.1d).
rstp specifies rapid spanning tree protocol (RSTP,802.1w).
[no] spanning-tree port mcheck
Description:
Force the port to transmit RST BPDUs.
No format means not force the port to transmit RST BPDUs.
Syntax:
[no] spanning-tree port mcheck [<port-list>]
Parameters:
specifies the ports to be set. Null means all ports.
[no] spanning-tree port edge-port
Description:
Set the port to be edge connection. No format means set the port to be non-edge connection.
Syntax:
[no] spanning-tree port edge-port [<port-list>]
Parameters:
specifies the ports to be set. Null means all ports.
spanning-tree protocol version

[no] spanning-tree port non-stp
Description:
Disable or enable spanning tree protocol on this port.
Syntax:
[no] spanning-tree port non-stp [<port-list>]
Parameters:
specifies the ports to be set. Null means all ports.
Description:
Set the port to be point to point connection.
Syntax:
spanning-tree port point-to-point-mac <auto | true | false> [<port-list>]
Parameters:
auto specifies point to point link auto connection.
true specifies point to point link true.
false specifies point to point link false.
specifies the ports to be set. Null means all ports.
Description:
Show spanning-tree information of CIST.
Description:
Show spanning tree port information of CIST.
Syntax:
show spanning-tree port [<port-list>]
Parameters:
specifies the port to be shown. Null means all ports.
spanning-tree point-to-point mac · show spanning-tree · show spanning-tree port

Any Network Management system running the simple Network Management Protocol (SNMP) can be managed by the switch.
Description:
Enable or disable SNMP.
Description:
Show the enable or disable status of SNMP.
Description:
Set agent system name string.
Syntax:
Parameters:
specifies the system name string.
e.g. snmp system-name SWITCH

Description:
Set agent location string.
Syntax:
Parameters:
specifies the location string.
e.g. snmp system-location office
Description:
Set agent system contact string.
Syntax:
Parameters:
specifies the contact string.
e.g. snmp system-contact abc@sina.com
Description:
Show SNMP system information.

Description:
Set SNMP community string.
Syntax:
snmp community <read-sysinfo-only | read-all-only | read-write-all><community- str>
Parameters:
specifies the community string.
e.g. snmp community read-all-only public
Description:
Delete SNMP community string.
Syntax:
no snmp community <community-str>
Parameters:
specifies the community string.
e.g. no snmp community public
Description:
Show SNMP community strings.
snmp community · no snmp community · show snmp community

Description:
Set SNMP trap receiver IP address, community string, and port number.
Syntax:
snmp trap <ip-addr> [<community-str>] [<1..65535>]
Parameters:
specifies the IP address.
specifies the community string.
specifies the trap receiver port number.
e.g. snmp trap 192.168.200.1 public
Description:
Remove trap receiver IP address and port number.
Syntax:
no snmp trap <ip-addr> [<1..65535>]
Parameters:
specifies the IP address.
specifies the trap receiver port number.
e.g. no snmp trap 192.168.200.1
Description:
Show all trap receivers.
snmp trap · no snmp trap · show snmp trap

The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite.
Description:
Enable/disable IGMP snooping.
Syntax:
Description:
Enable/disable IGMP snooping fast leave. If enable, switch will fast delete member who send leave report, else wait one sec.
Syntax:
Description:
Enable/disable IGMP snooping querier.
Syntax:
Description:
Enable/disable IGMP snooping CrossVLAN
Syntax:

Description:
Enable/disable IGMP snooping debugging output.
Syntax:
Description:
Show IGMP snooping information.
Syntax:
show igmp <status | router | groups | table>
Parameters:
status specifies IGMP snooping status and statistics information.
router specifies IGMP snooping router's IP address.
groups specifies IGMP snooping multicast group list.
table specifies IGMP snooping IP multicast table entries.
Description:
Clear IGMP snooping statistics counters.

Description:
Enable or disable 802.1x.
Syntax:
Description:
Set radius server IP, port number, and accounting port number.
Syntax:
radius-server host <ip-addr> <1024..65535> <1024..65535>
Parameters:
specifies server's IP address.
The first specifies the server port number.
The second specifies the accounting port number.
Description:
Set 802.1x shared key.
Syntax:
Parameters:
specifies shared key string.

Description:
Set 802.1x NAS identifier.
Syntax:
Parameters:
specifies NAS identifier string.
Description:
Show radius server information, including radius server IP, port number, accounting port number, shared key, NAS identifier,
Description:
Syntax:
dot1x timeout quiet-period <0..65535>
Parameters:
specifies the quiet period, in seconds.
Description:
Set 802.1x Tx period. (default: 15 seconds).
Syntax:
dot1x timeout tx-period <0..65535>
Parameters:
specifies the Tx period, in seconds.

Description:
Syntax:
dot1x timeout supplicant <1..300>
Parameters:
specifies the supplicant timeout, in seconds.
Description:
Set radius server timeout (default: 30 seconds).
Syntax:
dot1x timeout radius-server <1..300>
Parameters:
specifies the radius server timeout, in seconds.
Description:
Set 802.1x maximum request retries (default: 2 times).
Syntax:
dot1x max-req <1..10>
Parameters:
specifies the maximum request retries.
Description:
Set 802.1x re-auth period (default: 3600 seconds).
Syntax:
dot1x timeout re-authperiod <30..65535>
Parameters:
specifies the re-auth period, in seconds.

Description:
Show 802.1x information, quiet period, Tx period, supplicant timeout, server timeout, maximum requests, and re-auth period.
Description:
Set 802.1x per port information.
Syntax:
dot1x port <fu | fa | au | no> <port-list>
Parameters:
fu specifies forced unauthorized.
fa specifies forced authorized.
au specifies authorization.
no specifies disable authorization.
specifies the ports to be set.
Description:
Show 802.1x per port information.
show dot1x · dot1x port · show dot1x port

Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be used to block packets by maintaining a table of packet fragments indexed by source and destination IP address, protocol, and so on.
Description:
Delete ACL group.
Syntax:
Parameters:
specifies the group id.
e.g. no acl 1
Description:
Reset the ACL group count.
Syntax:
no acl count <GroupId>
Parameters:
GroupId: specifies the group id.
no acl · no acl <1-220> · no acl count

Description:
Show ACL group information.
Syntax:
Parameters:
specifies the group id, null means all valid groups.
e.g.
Switch(config)# show acl 1
Switch(config)# show acl 1
Rules:
show acl · show acl [<1-220>] ·

acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255>
Description:
Add or edit ACL group for Ipv4.
Syntax:
acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255> A.B.C.D (check|unCheck) <0-65535> <0-26>
Parameters:
(add|edit) specifies the operation.
<1-220> specifies the group id.
(permit|deny) specifies the action. permit: permit packet cross switch; deny: drop packet.
<0-4094> specifies the VLAN id. 0 means don't care.
<0-255> specifies the IP protocol. 0 means don't care.
A.B.C.D specifies the Source IP address. 0.0.0.0 means don't care.
A.B.C.D specifies the Mask. 0.0.0.0 means don't care, 255.255.255.255 means compare all.
A.B.C.D specifies the Destination IP Address. 0.0.0.0 means don't care.
A.B.C.D specifies the Mask. 0.0.0.0 means don't care, 255.255.255.255 means compare all.
(check|unCheck) specifies the IP Fragment. check: Check IP fragment field; unCheck: Not check IP fragment field.
<0-65535> specifies the Destination port number if TCP or UDP. 0 means don't care.
<0-26> specifies the Port id. 0 means don't care.
e.g.
Switch(config)# acl add 1 deny 1 ipv4 0 192.168.1.1 255.255.255.255 0.0.0.0 0.0.0.0 unCheck 0 0
This ACL rule will drop all packet from IP is 192.168.1.1 with VLAN id=1 and IPv4.

acl (add|edit) <1-220> (qosvoip) <0-4094>
Description:
Add or edit ACL group for Ipv4.
Syntax:
acl (add|edit) <1-220> (qosvoip) <0-4094> <0-7> <0-1F> <0-1F> <0-FF> <0-FF> <0- FFFF> <0-FFFF> <0-FFFF> <0-FFFF>
Parameters:
(add|edit) specifies the operation.
<1-220> specifies the group id.
(qosvoip) specifies the action, do qos voip packet adjustment.
<0-4094> specifies the VLAN id. 0 means don't care.
<0-1F> specifies the port ID value.
<0-1F> specifies the port ID mask.
<0-FF> specifies the protocol value.
<0-FF> specifies the protocol mask.
<0-FFFF> specifies the source port value.
<0-FFFF> specifies the source port mask.
<0-FFFF> specifies the destination port value.
<0-FFFF> specifies the destination mask.
e.g. acl add 1 qosvoip 1 7 1 1 0
no acl <1-220> and show acl [<1-220>] commands are same as Ipv4 ACL commands.

acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-65535>
Description:
Add or edit ACL group for non-Ipv4.
Syntax:
acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-65535>
Parameters:
(add|edit) specifies the operation.
<1-220> specifies the group id.
(permit|deny) specifies the action. permit: permit packet cross switch; deny: drop packet.
<0-4094> specifies the VLAN id. 0 means don't care.
<0-65535> specifies the Ether Type. 0 means don't care.
e.g. acl add 1 deny 0 nonipv4 2054. This ACL rule will drop all packets for either type is 0x0806 and non-IPv4.

Let device that has specific IP address and MAC address can use network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match.
Description:
Enable binding function.
Description:
Disable binding function.
Description:
Delete Binding group.
Syntax:
Parameters:
specifies the group id.
e.g. no bind 1

Description:
Show Binding group information.
Syntax:
Parameters:
specifies the group id, null means all valid groups.
e.g. show bind 1
Description:
Add Binding group.
Syntax:
bind add <1-220> A:B:C:D:E:F <0-4094> A.B.C.D <1-26>
Parameters:
specifies the group id.
A.B.C.D specifies the MAC address.
specifies the VLAN id. 0 means don't care.
A.B.C.D specifies the Source IP address. 0.0.0.0 means don't care.
A.B.C.D specifies the IP Address.
specifies the Port id.
e.g.
Switch(config)# bind add 1 00:11:22:33:44:55 0 192.168.1.1 1
This Binding rule will permit all packet cross switch from device's IP is 192.168.1.1 and MAC is 00:11:22:33:44:55 and this device connect to switch port id=1.
show bind · show bind [<1-220>] · bind add


poe temperature-protection Enabling or disabling the PoE power supply over temperature protection
poe limit-mode Configure System PoE power limit mode information
poe enable Enabling or disabling the port POE injects function
poe priority Set port priority for the power supply management
poe maximum-power Enabling or disabling per port power output limit
Description:
Show System Power over Ethernet information
Example:

show poe · Command Level · Global Configuration

Description:
Show per PoE port information
Syntax:
show poe status [<port-list>]
Parameters:
specifies the ports to be set. If not entered, all ports are set.
Example 1:

Example 2:

show poe status · Command Level · Global Configuration

Description:
Configure PoE over temperature protection to enable or disable
Syntax:
poe temperature-protection { enable / disable }
Parameters:
Enable PoE power budget change automatically by detected PoE unit temperature
Disable PoE power budget change automatically
Description:
Configure System PoE power limit mode information
Syntax:
poe limit-mode { Port-Priority / Total-Limit }
Parameters:
Deliver PoE power by port priority setting
Set limit value of the total POE port provided power to the PDs.

Example:
Switch(config)# poe limit-mode port-priority

Switch (config)# no poe limit-mode


Description:
Enabling or disabling the port POE injects function.
Command Level:
Syntax:
[no] poe enable [<port-list>]
Parameters:
specifies the ports to be set. If not entered, all ports are set.
Example:
Switch(config)# poe enable 1

Switch(config)# no poe enable 1

poe enable · Global Configuration · poe enable [<port-list>]

Description:
Set port priority for the power supply management.
The command is configurable while "poe limit-mode" is set to "Port Priority"
Command Level:
Syntax:
poe priority { Critical | High | Low} [<port-list>]
Parameters:
{Critical | High | Low}
specifies the ports to be set. If not entered, all ports are set.
Example:
Switch(config)# poe priority low 1

poe priority · Global Configuration

Description:
Enabling or disabling per port power output limit.
The command is configurable while "poe limit-mode" is set to "Total-Limit"
Command Level:
Syntax:
poe maximum-power <1-15.4> [<port-list>]
no poe mximum-power [<port-list>]
Parameters:
specifies the ports to be set. If not entered, all ports are set.
Example:
Switch(config)# poe maximum-power 10 1

poe maximum-power · Global Configuration


The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. This information comes from the learning process of Ethernet Switch.
When one packet comes in from any port, the Switch will record the source address, port no. And the other related information in address table. This information will be used to decide either forwarding or filtering for future packets.
When one packet comes from some port of the Ethernet Switching, it will also check the destination address besides the source address learning. The Ethernet Switching will lookup the address-table for the destination address. If not found, this packet will be forwarded to all the other ports except the port, which this packet comes in. And these ports will transmit this packet to the network it connected. If found, and the destination address is located at different port from this packet comes in, the Ethernet Switching will forward this packet to the port where this destination address is located according to the information from address table. But, if the destination address is located at the same port with this packet comes in, then this packet will be filtered. Thereby increasing the network throughput and availability

Store-and-Forward is one type of packet-forwarding techniques. A Store-and- Forward Ethernet Switching stores the incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets occurrence, it is the best choice when a network needs efficiency and stability.
The Ethernet Switch scans the destination address from the packet-header, searches the routing table pro-vided for the incoming port and forwards the packet, only if required. The fast forwarding makes the switch attractive for connecting servers directly to the network, thereby increasing throughput and availability. However, the switch is most commonly used to segment existence hubs, which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters.
Due to the learning function of the Ethernet switching, the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets whose destination address is on the same segment as the source address. This confines network traffic to its respective domain and reduce the overall load on the network.
The Switch performs "Store and forward" therefore, no error packets occur. More reliably, it reduces the re-transmission rate. No packet loss will occur.
The STP ports on the Switch have built-in "Auto-negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset). This is done by detect the modes and speeds at the second of both device is connected and capable of, both 10Base-T and 100Base-TX devices can connect with the port in either Half- or Full- Duplex mode.
10Mbps, no auto-negotiation 10Mbps.
10Mbps, with auto-negotiation 10/20Mbps (10Base-T/Full-Duplex)
100Mbps, no auto-negotiation 100Mbps
100Mbps, with auto-negotiation 100/200Mbps (100Base-TX/Full-Duplex)

What is PoE?
Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet, the most widely installed local area network technology adopted today. PoE allows the electrical power necessary for the operation of each end-device to be carried by data cables rather than by separate power cords. New network applications, such as IP Cameras, VoIP Phones, and Wireless Networking, can help enterprises improve productivity. It minimizes wires that must be used to install the network for offering lower cost, and less power failures.
IEEE802.3af also called Data Terminal equipment (DTE) power via Media dependent interface (MDI) is an international standard to define the transmission for power over Ethernet. The 802.3af is delivering 48V power over RJ-45 wiring. Besides 802.3af also define two types of source equipment: Mid-Span and End-Span.
Mid-Span device is placed between legacy switch and the powered device. Mid-Span is tap the unused wire pairs 4/5 and 7/8 to carry power, the other four is for data transmit.
End-Span device is direct connecting with power device. End-Span could also tap the wire 1/2 and 3/6.

The specification of PoE typically requires two devices: the Powered Source Equipment (PSE) and the Powered Device (PD). The PSE is either an End-Span or a Mid- Span, while the PD is a PoE-enabled terminal, such as IP Phones, Wireless LAN, etc. Power can be delivered over data pairs or spare pairs of standard CAT-5 cabling.
A standard CAT5 Ethernet cable has four twisted pairs, but only two of these are used for 10BASE-T and 100BASE-T. The specification allows two options for using these cables for power, shown in Figure 99 and Figure 100:
The spare pairs are used. Figure 99 shows the pair on pins 4 and 5 connected together and forming the positive supply, and the pair on pins 7 and 8 connected and forming the negative supply. (In fact, a late change to the spec allows either polarity to be used).


The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity.

When to install PoE?
Consider the following scenarios:
References:
IEEE Std 802.3af-2003 (Amendment to IEEE Std 802.3-2002, including IEEE Std 802.3ae-2002), 2003 Page(s):0_1-121
White Paper on Power over Ethernet (IEEE802.3af)

http://www.poweroverethernet.com/articles.php?article_id=52
http://www.microsemi.com/PowerDsine/
While adding PoE support to networked devices is relatively painless, it should be realized that power cannot simply be transferred over existing CAT-5 cables. Without proper preparation, doing so may result in damage to devices that are not designed to support provision of power over their network interfaces.
The PSE is the manager of the PoE process. In the beginning, only small voltage level is induced on the port's output, till a valid PD is detected during the Detection period. The PSE may choose to perform classification, to estimate the amount of power to be consumed by this PD. After a time-controlled start-up, the PSE begins supplying the 48 VDC level to the PD, till it is physically or electrically disconnected. Upon disconnection, voltage and power shut down.
Since the PSE is responsible for the PoE process timing, it is the one generating the probing signals prior to operating the PD and monitoring the various scenarios that may occur during operation.
All probing is done using voltage induction and current measurement in return.

Detection Measure whether powered device has the correct signature resistance of 15–33 kΩ 2.7-10.0 1.8–10.0
Classification Measure which power level class the resistor indicates 14.5-20.5 12.5–25.0
Startup Where the powered device will startup >42 >38
Microsemi /PowerDsine · Linear Tech

Before power is applied, safety dictates that it must first be ensured that a valid PD is connected to the PSE's output. This process is referred to as "line detection", and involves the PSE seeking a specific, 25 KO signature resistor. Detection of this signature indicates that a valid PD is connected, and that provision of power to the device may commence.
The signature resistor lies in the PD's PoE front-end, isolated from the rest of the PD's circuitries till detection is certified.
Once a PD is detected, the PSE may optionally perform classification, to determine the maximal power a PD is to consume. The PSE induces 15.5-20.5 VDC, limited to 100 mA, for a period of 10 to 75 ms responded by a certain current consumption by the PD, indicating its power class.
The PD is assigned to one of 5 classes: 0 (default class) indicates that full 15.4 watts should be provided, 1-3 indicate various required power levels and 4 is reserved for future use. PDs that do not support classification are assigned to class 0. Special care must be employed in the definition of class thresholds, as classification may be affected by cable losses.
Classifying a PD according to its power consumption may assist a PoE system in optimizing its power distribution. Such a system typically suffers from lack of power resources, so that efficient power management based on classification results may reduce total system costs.
Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full voltage capacity (44-57 Volts) over a minimal amount of time (above 15 microseconds).
A gradual startup is required, as a sudden rise in voltage (reaching high frequencies) would introduce noise on the data lines.
Once provision of power is initiated, it is common for inrush current to be experienced at the PSE port, due to the PD's input capacitance. A PD must be designed to cease inrush current consumption (of over 350 mA) within 50 ms of power provision startup.
During normal operation, the PSE provides 44-57 VDC, able to support a minimum of 15.4 watts power.

The IEEE 802.3af standard defines handling of overload conditions. In the event of an overload (a PD drawing a higher power level than the allowed 12.95 Watts), or an outright short circuit caused by a failure in cabling or in the PD, the PSE must shut down power within 50 to 75 milliseconds, while limiting current drain during this period to protect the cabling infrastructure. Immediate voltage drop is avoided to prevent shutdown due to random fluctuations.
The IEEE 802.3af standard requires that devices powered over Ethernet be disconnected safely (i.e. power needs be shut down within a short period of time following disconnection of a PD from an active port).
When a PD is disconnected, there is a danger that it will be replaced by a non-PoE- ready device while power is still on. Imagine disconnecting a powered IP phone utilizing 48 VDC, then inadvertently plugging the powered Ethernet cable into a non- PoE notebook computer. What's sure to follow is not a pretty picture.
The standard defines two means of disconnection, DC Disconnect and AC Disconnect, both of which provide the same functionality - the PSE shutdowns power to a disconnected port within 300 to 400ms. The upper boundary is a physical human limit for disconnecting one PD and reconnecting another.
DC Disconnect detection involves measurement of current. Naturally, a disconnected PD stops consuming current, which can be inspected by the PSE. The PSE must therefore disconnect power within 300 to 400 ms from the current flow stop. The lower time boundary is important to prevent shutdown due to random fluctuations.
This method is based on the fact that when a valid PD is connected to a port, the AC impedance measured on its terminals is significantly lower than in the case of an open port (disconnected PD).
AC Disconnect detection involves the induction of low AC signal in addition to the 48 VDC operating voltage. The returned AC signal amplitude is monitored by the PSE at the port terminals. During normal operation, the PD's relatively low impedance lowers the returned AC signal while a sudden disconnection of this PD will cause a surge to the full AC signal level and will indicate PD disconnection.

This chapter contains information to help you solve common problems. If the Ethernet Switch is not functioning properly, make sure the Ethernet Switch was set up according to the instructions in this manual.
The Link LED is not lit
Solution:
Check the cable connection and remove duplex mode of the Ethernet Switch
Some stations cannot talk to other stations located on the other port
Solution:
Check the VLAN settings, trunk settings, or port enabled / disabled status.
Solution:
Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to half duplex, then the performance will be poor. Please also check the in/out rate of the port.
Why the Switch doesn't connect to the network?
Solution:
Performance is poor

100Base-TX port link LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.
Switch does not power up
Solution:
While IP Address be changed or forgotten admin password –
To reset the IP address to the default IP Address “192.168.0.100” or reset the password to default value. Press the hardware reset button at the front panel about 10 seconds. After the device is rebooted, you can login the management WEB interface within the same subnet of 192.168.0.xx.

Reset

Switch's RJ-45 Pin Assignments
2 BI_DABI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DCBI_DD-
6 BI_DBBI_DA-
7 BI_DD+ BI_DC+
8 BI_DDBI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
1000Mbps, 1000Base T · Contact MDI MDI-X

When connecting your 10/100Mbps Ethernet Switch to another switch, a bridge or a hub, a straight or crossover cable is necessary. Each port of the Switch supports auto-MDI/MDI-X detection. That means you can directly connect the Switch to any Ethernet devices without making a crossover cable. The following table and diagram show the standard RJ-45 receptacle/ connector and their pin assignments:
RJ-45 Connector pin assignment
1 Tx + (transmit) Rx + (receive)
2 Tx - (transmit) Rx - (receive)
3 Rx + (receive) Tx + (transmit)
4, 5 Not used
6 Rx - (receive) Tx - (transmit)
7, 8 Not used
The standard cable, RJ-45 pin assignment
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
The standard RJ-45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:
Contact MDI · Media Dependant Interface · Media Dependant Interface-Cross

Straight Cable SIDE 1 SIDE2 SIDE 1 1
1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown
1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown
Crossover Cable SIDE 1 SIDE2 SIDE 1 1
1 = White / Orange 2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown
1 = White / Green 2 = Green 3 = White / Orange 4 = Blue 5 = White / Blue 6 = Orange 7 = White / Brown 8 = Brown
Please make sure your connected cables have the same pin assignment ands color as the above picture before deploying the cables into your network.


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.