EN
Gateway logo
Official user manual

Gateway S466

112 pages·2.3 MB·Computer Hardware·PDF·ENDEFRITNLJA
Gateway S466
Table of Contents 80 sections Voltage Differential SCSI · Single Ended and Low- · PCI RAID Controller · ADAC Ultra2 S466 · … ShowHide
Voltage Differential SCSIp.1Single Ended and Low-p.1PCI RAID Controllerp.1ADAC Ultra2 S466p.1Hardware Guidep.1Revision Historyp.2Prefacep.7Preface, Continuedp.8ADAC Ultra2 S466 Problem Report Formp.9Logical Drive Configurationp.9LD1p.9LD2p.9LD3p.9LD4p.9LD5p.9LD6p.9LD7p.9LD8p.9Physical Device Layoutp.10Warning: Changes or modifications to this unit not expressly approvedp.13by the party responsible for compliance could void the user’s authorityp.13Shielded interface cables must be used with this product to ensurep.13Gateway ADAC Ultra2 S466 PCI RAID Controllerp.13FCC Regulatory Statementp.13Disclaimerp.141 Overviewp.15Maximum Cable Length for SCSI Standardsp.16Single Ended and Differential SCSI Busesp.16SCSI Bus Widths and Maximum Throughputp.16Documentationp.17ADAC Ultra2 S466 Block Diagramp.182 Introduction to RAIDp.19RAID Benefitsp.19ADAC Ultra2 S466 – Host-Based RAID Solutionp.21Consistency Checkp.22Fault Tolerancep.22RAID Overviewp.22Disk Stripingp.23Spanning for RAID 10, RAID 30, or RAID 50p.24Disk Spanningp.24Disk Mirroringp.25Parityp.26Importantp.27Hot Sparesp.27Disk Rebuildp.28Logical Drivep.29Hot Swapp.29Logical Drive Statesp.30SCSI Drive Statesp.30Enclosure Managementp.31Disk Array Typesp.313 RAID Levelsp.33Selecting a RAID Levelp.34RAID 0p.35RAID 1p.36RAID 3p.37RAID 3, Continuedp.38RAID 5p.39RAID 10p.40RAID 30p.41RAID 50p.424 ADAC Ultra2 S466 Featuresp.43Hardware Requirementsp.44Configuration Featuresp.44Hardware Architecture Featuresp.45Array Performance Featuresp.45RAID Management Featuresp.46Fault Tolerance Featuresp.46Operating System Software Driversp.47Software Utilitiesp.47ADAC Ultra2 S466 Specificationsp.48ADAC Ultra2 S466 BIOSp.49PCI Bridge/CPUp.49Cache Memoryp.49Onboard Speakerp.50Serial Portp.50SCSI Busp.50SCSI Connectorsp.51SCSI Terminationp.51SCSI Firmwarep.51
Page 1 of the Gateway S466 user manual — Voltage Differential SCSI
Page 1 · click to enlarge
Page 1

8503624 A MAN US ADAC U2 S466 GDE R0 8/14/98

Voltage Differential SCSI

Single Ended and Low-

PCI RAID Controller

ADAC Ultra2 S466

Hardware Guide

Page 2 of the Gateway S466 user manual — Revision History
Page 2 · click to enlarge
Page 2

language or computer language, or transmitted in any form whatsoever without the prior written

this publication can be reproduced, transcribed, stored in a retrieval system, translated into any

consent of the publisher, Gateway, Inc. Gateway, Inc. acknowledges the following trademarks:

IBM, AT, VGA, PS/2, and OS/2 are registered trademarks and XT and CGA are trademarks of

This publication contains proprietary information which is protected by copyright. No part of

MS-DOS, and Microsoft are registered trademarks of Microsoft Corporation. Windows 95,

SCO, UnixWare, and Unix are registered trademarks of the Santa Cruz Operation. Inc.

Microsoft Windows and Windows NT are trademarks of Microsoft Corporation.

Hewlett-Packard is a registered trademark of Hewlett-Packard Corporation.

Novell NetWare is a registered trademark of Novell Corporation.

NEC is a registered trademark of Nippon Electric Corporation.

Siemens is a registered trademark of Siemens Corporation.

Intel is a registered trademark of Intel Corporation.

International Business Machines Corporation.

AMP is a trademark of AMP Corporation.

ADAC Ultra2 S466 Hardware Guide ii

© Copyright 1998 Gateway, Inc.

6/8/98 Initial release.

Revision History

All rights reserved.

Page 3 of the Gateway S466 user manual — Revision History
Page 3 · click to enlarge
Page 3
Page 3 of the Gateway S466 user manual — Revision History
Page 4 of the Gateway S466 user manual — Revision History
Page 4 · click to enlarge
Page 4
Page 4 of the Gateway S466 user manual — Revision History
Page 5 of the Gateway S466 user manual — Revision History
Page 5 · click to enlarge
Page 5
Page 5 of the Gateway S466 user manual — Revision History
Page 6 of the Gateway S466 user manual — Revision History
Page 6 · click to enlarge
Page 6
Page 6 of the Gateway S466 user manual — Revision History
Page 7 of the Gateway S466 user manual — Preface
Page 7 · click to enlarge
Page 7

The ADAC Ultra2 S466 PCI RAID Controller supports all single

Gateway’s discretion according to the terms and conditions of the

damage, direct, incidental or consequential resulting from the use

with the product). No action or proceeding against Gateway may

be commenced more than two years after the delivery of product

Licensee agrees to defend and indemnify Gateway from any and

all claims, suits, and liabilities (including attorney’s fees) arising

out of or resulting from any actual or alleged act or omission on

agents, in connection with the distribution of Licensed Software

use of Licensee’s product not caused solely by faults in Licensed

Limitations of Liability Gateway, Inc. shall in no event be held liable for any loss,

indirect, incidental, or consequential (whether arising from the

design or use of this product or the support materials provided

the part of Licensee, its authorized third parties, employees, or

liability for bodily or other injuries to end-users resulting from

ended and low-voltage differential (LVD) SCSI devices on an

Ultra and Wide SCSI channel with data transfer rates up to 80

MB/s (Megabytes per second). This manual describes ADAC

Gateway is only obligated to repair or replace this product at

expenses, or damages of any kind whatsoever, whether direct,

to end-users, including, without limitation, claims, suits, and

Limited Warranty The buyer agrees if this product proves to be defective, that

Gateway shall not be liable in tort or contract for any loss or

of this product. Please see the Warranty Registration Card

warranty registration card that accompanies this product.

shipped with this product for full warranty details.

Software as provided by Gateway to Licensee.

to Licensee of Licensed Software.

Ultra2 S466.

Preface

Cont’d · Preface vii

Page 8 of the Gateway S466 user manual — Preface, Continued
Page 8 · click to enlarge
Page 8
  • diskette(s) with the ADAC Ultra2 S466 software, and

Brochure that was included with your system. Before you

  • a ADAC Ultra2 S466 Configuration Software Guide,

Technical Support If you need help installing, configuring, or running the

Gateway OEM Technical Support representative. For the

Web Site We invite you to access the Gateway world wide web site

call, please complete the ADAC Ultra2 S466 Problem

  • a ADAC Ultra2 S466 Operating System Drivers

ADAC Ultra2 S466 PCI RAID Controller, call your

  • a ADAC Ultra2 S466 PCI RAID Controller,

current number, refer to the Assistance Resources

  • a ADAC Ultra2 S466 Hardware Guide ,
  • software license agreement,
  • a warranty registration card.

Report form on the next page.

Package Contents You should have received:

http://www.gateway.com.

ADAC Ultra2 S466 Hardware Guide viii

Preface, Continued

at:

Guide,

Page 9 of the Gateway S466 user manual — Logical Drive Configuration
Page 9 · click to enlarge
Page 9
Gateway S466 — ADAC Ultra2 S466 Problem Report Form diagram (page 9)
Fig. 1 · ADAC Ultra2 S466 Problem Report Form

Policy # of Physical

ADAC Ultra2 S466 Problem Report Form

Steps necessary to re-create problem:

Logical Drive Configuration

LD1

LD2

LD3

LD4

LD5

LD6

LD7

LD8

Customer InformationADAC Ultra2 S466 Information NameToday’s Date CompanyDate of Purchase AddressInvoice Number City/StateSerial Number Country email addressCache Memory PhoneFirmware Version FaxBIOS Version System Information Motherboard:BIOS manufacturer: Operating System:BIOS Date: Op. Sys. Ver.:Video Adapter:
Show 9 more labels / short text on this page
Preface ix · Drives · Policy Write · Policy Read · Size Cache · Size Logical Drive · Level Stripe · Drive RAID · Logical
Page 10 of the Gateway S466 user manual — Physical Device Layout
Page 10 · click to enlarge
Page 10
Gateway S466 — Physical Device Layout diagram (page 10)
Fig. 2 · Physical Device Layout

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

ADAC Ultra2 S466 Hardware Guide x

Physical Device Layout

Channel 1 Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type
Show 12 more labels / short text on this page
Manufacturer/Model Number · Manufacturer/Model Number · Manufacturer/Model Number · Firmware level · Device Type · Firmware level · Device Type · Firmware level · Device Type · Target ID · Target ID · Target ID
Page 11 of the Gateway S466 user manual — Physical Device Layout
Page 11 · click to enlarge
Page 11
Gateway S466 — Physical Device Layout diagram (page 11)
Fig. 3 · Physical Device Layout
Channel 1 Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type

Preface xi · Manufacturer/Model Number · Firmware level

Page 12 of the Gateway S466 user manual — Preface, Continued
Page 12 · click to enlarge
Page 12

exemplary, consequential or otherwise, that may result from such

any kind, either expressed or implied, including, but not limited

Ultra2 S466 Disk Array Controller. Although efforts have been

made to assure the accuracy of the information contained here,

information, and for damages, whether direct, indirect, special,

from the use or misuse of the manual or information contained

therein (even if Gateway has been advised of the possibility of

document or its contents should be addressed to Gateway at the

warranties or the limitation or exclusion of liability for indirect,

certain transactions; therefore, this statement may not apply to

error, including but not limited to the loss of profits resulting

Gateway provides this publication “as is” without warranty of

information herein; these changes will be incorporated in new

editions of the publication. Gateway may make improvements

Disclaimer This manual describes the operation of the Gateway ADAC

to, the implied warranties of merchantability or fitness for a

special, exemplary, incidental or consequential damages in

Requests for technical information about Gateway products

Gateway expressly disclaims liability for any error in this

such damages). Any questions or comments regarding this

Some states do not allow disclaimer of express or implied

typographical errors. Changes are periodically made to the

This publication could include technical inaccuracies or

and/or revisions in the product(s) and/or the program(s)

you. Also, you may have other rights which vary from

should be made to your Gateway representative.

described in this publication at any time.

address shown on the cover.

jurisdiction to jurisdiction.

ADAC Ultra2 S466 Hardware Guide xii

specific purpose.

Preface, Continued

Page 13 of the Gateway S466 user manual — FCC Regulatory Statement
Page 13 · click to enlarge
Page 13

This device complies with Part 15 of the FCC Rules. Operation is subject to

interference in a residential installation. This equipment generates, uses and

Warning: Changes or modifications to this unit not expressly approved

by the party responsible for compliance could void the user’s authority

for a Class B digital device, pursuant to Part 15 of the FCC Rules. These

accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will not

interference to radio or television reception, which can be determined by

turning the equipment off and on, try to correct the interference by one or

3. Connect the equipment into an outlet on a circuit different from

interference, and (2) this device must accept any interference received,

occur in a specific installation. If this equipment does cause harmful

the following two conditions(1) this device may not cause harmful

limits are designed to provide reasonable protection against harmful

Shielded interface cables must be used with this product to ensure

can radiate radio frequency energy and, if not installed and used in

4. Consult the dealer or an experienced radio/TV technician
2. Increase the separation between the equipment and

including interference that may cause undesired operation.

Gateway ADAC Ultra2 S466 PCI RAID Controller

1. Reorient or relocate the receiving antenna.

that to which the receiver is connected.

compliance with the Class B FCC limits.

FCC ID NumberIUESER466

FCC Regulatory Statement

Model NumberSeries 466

more of the following measures:

to operate the equipment.

the receiver.

for help.

Preface xiii

Page 14 of the Gateway S466 user manual — Disclaimer
Page 14 · click to enlarge
Page 14

Gateway only certifies that this product will work correctly when this

Gateway Compatibility Report for this product. Call your Gateway

sales representative for a copy of the Compatibility Report for this

product is used with the same jumper settings, the same system

peripherals that were tested by Gateway with this product. The

complete list of tested jumper settings, system configurations,

peripheral devices, and memory modules are documented in the

configuration, the same memory module parts, and the same

Disclaimer

product.

ADAC Ultra2 S466 Hardware Guide xiv

Page 15 of the Gateway S466 user manual — 1 Overview
Page 15 · click to enlarge
Page 15

disk subsystem management. The ADAC Ultra2 S466 is an

and Wide SCSI channel supporting data transfer rates up to

EDO DRAM cache memory in a SIMM socket used for read

SCSI Channel The ADAC Ultra2 S466 upgrade card includes one Fast-20

SCSI channel. The channel is powered by a Symbios Logic

Chapter 1 Overview 1

entry level-to mid-range RAID controller solution. ADAC

  • performs synchronous operation on a wide LVD SCSI bus,
  • includes an Intel® i960RP that performs RAID calculations
  • supports 4, 8, 16, 32, 64, or 128 MB of Fast Page Mode or

external connector for external storage subsystem and one

provides reliability, high performance, and fault-tolerant

80 Megabytes per second (MB/s) per channel. The SCSI channel supports up to fifteen non-Ultra SCSI devices.

The ADAC Ultra2 S466 PCI RAID controller is a high

RAID in a server. The ADAC Ultra2 S466 has an Ultra

performance intelligent PCI-to-SCSI host adapter with

Ultra2 S466 offers a cost-effective way to implement

  • provides a high performance I/O migration path while

and write-back caching and RAID 5 parity generation.

NVRAM and Flash ROM A 32 KB x 8 NVRAM stores RAID system

SCSI Connectors ADAC Ultra2 S466 has one ultra high density 68-pin

  • allows up to 15 LVD SCSI devices on the wide bus,

RAID control capabilities. The ADAC Ultra2 S466

configuration information. The ADAC Ultra2 S466

firmware is stored in flash ROM for easy upgrade.

  • Performs SCSI data transfers up to 80 MB/s,

ADAC Ultra2 S466 Features ADAC Ultra2 S466 features:

preserving existing PCI-SCSI software,

high density 68-pin internal connector.

53C895 (Fast-40) SCSI processor.

1 Overview

and routing and

Page 16 of the Gateway S466 user manual — SCSI Bus Widths and Maximum Throughput
Page 16 · click to enlarge
Page 16
Gateway S466 — Maximum Cable Length for SCSI Standards diagram (page 16)
Fig. 4 · Maximum Cable Length for SCSI Standards

SCSI Standard SCSI Bus Width SCSI Throughput

SCSI I 8 bits 5 MB/s Fast SCSI 8 bits 10 MB/s Fast Wide SCSI 16 bits 20 MB/s Ultra SCSI 8 bits 20 MB/s Wide Ultra SCSI 16 bits 40 MB/s Ultra 2 SCSI 8 bits 40 MB/s Wide Ultra 2 SCSI 16 bits 80 MB/s

The SCSI standard defines two electrical buses:

SCSI I 6 m 12 m 7 Fast SCSI 6 m 12 m 7 Fast Wide SCSI 6 m 12 m 15 Ultra SCSI 1.5 m 12 m 7 Ultra SCSI 3 m 12 m 3 Wide Ultra SCSI 12 m 15 Wide Ultra SCSI 1.5 m 12 m 7 Wide Ultra SCSI 3 m 12 m 3 Ultra 2 SCSI 25 m 1 Ultra 2 SCSI 12 m 7 Wide Ultra 2 SCSI 25 m 1 Wide Ultra 2 SCSI 12 m 15

Maximum Cable Length for SCSI Standards

Single Ended and Differential SCSI Buses

  • low-voltage differential bus.

SCSI Bus Widths and Maximum Throughput

  • a single ended bus and
Page 17 of the Gateway S466 user manual — Documentation
Page 17 · click to enlarge
Page 17

Chapter 1 Overview 3

overview, RAID planning, and RAID system configuration

ADAC Ultra2 S466 Operating System Drivers Guide This manual provides

ADAC Ultra2 S466 Configuration Software Guide This manual describes

information you will need first. Read the ADAC Ultra2

detailed information about installing the ADAC Ultra2

the software configuration utilities that configure and

The ADAC Ultra2 S466 documentation set includes:

Using ADAC Ultra2 S466 Manuals This manual contains the RAID

S466 operating system drivers.

S466 Hardware Guide first.

modify RAID systems.

Documentation

Page 18 of the Gateway S466 user manual — ADAC Ultra2 S466 Block Diagram
Page 18 · click to enlarge
Page 18
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 5 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 6 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 7 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 8 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 9 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 10 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 11 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 12 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 13 · ADAC Ultra2 S466 Block Diagram
Gateway S466 — ADAC Ultra2 S466 Block Diagram diagram (page 18)
Fig. 14 · ADAC Ultra2 S466 Block Diagram

ADAC Ultra2 S466 Block Diagram

Page 19 of the Gateway S466 user manual — RAID Benefits
Page 19 · click to enlarge
Page 19

Improved I/O Although disk drive capabilities have improved drastically,

Chapter 2 Introduction to RAID 5

RAID (Redundant Array of Independent Disks) is an array

of multiple independent hard disk drives that provide high

single drive. The RAID array appears to the host computer

computers. Data loss because of a disk drive failure can be

management software configures and monitors RAID disk

generate more noise and vibration than electronic devices.

These factors reduce the reliability of data stored on disks.

performance and fault tolerance. A RAID disk subsystem

improves I/O performance over a computer using only a

as a single storage unit or as multiple logical units. I/O is

performance, and increases storage subsystem reliability.

RAID provides data security through fault tolerance and

actual performance has improved only three to four times

in the last decade. Computing performance has improved

subsystem operate more slowly, require more power, and

reliability and fault tolerance compared to single-drive

RAID has gained popularity because it: improves I/O

simultaneously. RAID systems improve data storage

recovered by reconstructing missing data from the

Increased Reliability The electromechanical components of a disk

expedited because several disks can be accessed

redundant data storage. The ADAC Ultra2 S466

over 50 times during the same time period.

2 Introduction to RAID

remaining data and parity drives.

arrays.

RAID Benefits

Page 20 of the Gateway S466 user manual — 2 Introduction to RAID
Page 20 · click to enlarge
Page 20
Page 20 of the Gateway S466 user manual — 2 Introduction to RAID
Page 21 of the Gateway S466 user manual — ADAC Ultra2 S466 – Host-Based RAID Solution
Page 21 · click to enlarge
Page 21

intelligence on an adapter card that is installed in a network

Chapter 2 Introduction to RAID 7

performance. ADAC Ultra2 S466 is part of the file server,

so it can transmit data directly across the computer’s buses

The available sequential data transfer rate is determined by

  • the sustained data transfer rate of the SCSI controller,

SCSI-to-SCSI A SCSI-to-SCSI RAID product puts the RAID intelligence

In SCSI-to-SCSI RAID products, the hard drive subsystem

The ADAC Ultra2 S466 controller is a host-based RAID

solution. ADAC Ultra2 S466 is a PCI adapter card that is

  • the sustained data transfer rate on the i960RP PCI to

Adapter installed in the network server. The data transfer

uses only a single SCSI ID, which allows you to connect

  • the sustained data transfer rate on the motherboard
  • the sustained data transfer rate of the SCSI devices,

rate is limited to the bandwidth of the SCSI channel. A

installed in any available PCI expansion slot in a host

SCSI-to-SCSI RAID product that has two wide SCSI

multiple drive subsystems to a single SCSI controller.

server. A host-based RAID product provides the best

Host-based solutions must provide operating system-

inside the RAID chassis and uses a plain SCSI Host

squeeze the data into a single wide SCSI (40 MB/s)

channels that operate at speeds up to 80 MB/s must

ADAC Ultra2 S466 – Host-Based RAID Solution

Host-Based A host-based RAID product puts all of the RAID

at data transfer speeds up to 132 MB/s.

  • the number of SCSI channels, and
  • the number of SCSI disk drives.

channel back to the host computer.

RAID products are either:

the following factors:

  • SCSI-to-SCSI.
  • host-based or

specific drivers.

system.

PCI bridge, · PCI bus,

Page 22 of the Gateway S466 user manual — Consistency Check
Page 22 · click to enlarge
Page 22

10, 30, and 50, special RAID versions supported by ADAC Ultra2 S466.

ensuring the reliability and stability of data stored on large

disk subsystems. A RAID system can be implemented in a

supplies, and the ability to hot swap drives. ADAC Ultra2

S466 provides hot swapping through the hot spare feature.

S466 supports all standard RAID levels and RAID levels

redundant data in an array. For example, in a system with

dedicated parity, checking consistency means computing

the parity of the data drives and comparing the results to

A hot spare drive is an unused online available drive that

ADAC Ultra2 S466 instantly plugs into the system when

After the hot spare is automatically moved into the RAID

Fault tolerance is achieved through cooling fans, power

subsystem, the failed drive is automatically rebuilt. The

collection of specifications that describe a system for

standard RAID levels are 0, 1, 3, and 5. ADAC Ultra2

In RAID, check consistency verifies the correctness of

RAID disk array continues to handle request while the

RAID (Redundant Array of Independent Disks) is a

number of different versions (or RAID Levels). The

the contents of the dedicated parity drive.

an active drive fails.

rebuild occurs.

Consistency Check

Fault Tolerance

RAID Overview

Page 23 of the Gateway S466 user manual — Disk Striping
Page 23 · click to enlarge
Page 23
Gateway S466 — Disk Striping diagram (page 23)
Fig. 15 · Disk Striping
Gateway S466 — Disk Striping diagram (page 23)
Fig. 16 · Disk Striping

Disk striping writes data across multiple disk drives instead

repeated sequential manner. The combined storage space is

accessed simultaneously; but disk striping does not provide

drives. ADAC Ultra2 S466 supports stripe sizes of 2 KB, 4

Chapter 2 Introduction to RAID 9

supports stripe sizes of 2 KB, 4 KB, 8 KB, 16 KB, 32 KB,

For example, in a four-disk system using only disk striping

of just one disk drive. Disk striping involves partitioning

each drive storage space into stripes that can vary in size

from 2 KB to 128 KB. These stripes are interleaved in a

composed of stripes from each drive. ADAC Ultra2 S466

where striping is implemented. For example, a four-disk

segments that ADAC Ultra2 S466 writes across multiple

Stripe Width Stripe width is the number of disks involved in an array

segment 2 is written to disk 2, and so on. Disk striping

(as in RAID level 0), segment 1 is written to disk 1,

enhances performance because multiple drives are

Stripe Size The stripe size is the length of the interleaved data

array with disk striping has a stripe width of four.

KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB.

64 KB, or 128 KB.

data redundancy.

Disk Striping

Page 24 of the Gateway S466 user manual — Disk Spanning
Page 24 · click to enlarge
Page 24
Gateway S466 — Spanning for RAID 10, RAID 30, or RAID 50 diagram (page 24)
Fig. 17 · Spanning for RAID 10, RAID 30, or RAID 50

Disk spanning allows multiple disk drives to function like

one big drive. Spanning overcomes lack of disk space and

Spanning alone does not provide reliability or performance

enhancements. Spanned logical drives must have the same

resources or adding relatively inexpensive resources. For

10 Configure RAID 10 by spanning two contiguous RAID 1 logical drives.

30 Configure RAID 30 by spanning two contiguous RAID 3 logical drives.

50 Configure RAID 50 by spanning two contiguous RAID 5 logical drives.

RAID level or add fault tolerance. It does increase the size of the logical

volume and improves performance by doubling the number of spindles.

simplifies storage management by combining existing

example, four 400 MB disk drives can be combined to

appear to the operating system as one single 1600 MB

graphic, RAID 1 array is turned into a RAID 10 array.

stripe size and must be contiguous. In the following

The RAID 1 logical drives must have the same stripe size.

The RAID 3 logical drives must have the same stripe size.

The RAID 5 logical drives must have the same stripe size.

Spanning for RAID 10, RAID 30, or RAID 50

drive.

Disk Spanning

Level Description

Page 25 of the Gateway S466 user manual — Disk Mirroring
Page 25 · click to enlarge
Page 25

drive is simultaneously written to another disk drive. If one

used to run the system and reconstruct the failed drive. The

100% data redundancy. Since the contents of the disk drive are completely written to a second drive, it does not matter

Chapter 2 Introduction to RAID 11

With mirroring (used in RAID 1), data written to one disk

disk drive fails, the contents of the other disk drive can be

if one of the drives fails. Both drives contain the same data

at all times. Either drive can act as the operational drive.

primary advantage of disk mirroring is that it provides

expensive because each drive in the system must be

Disk mirroring provides 100% redundancy, but is

Gateway S466 — Disk Mirroring diagram (page 25)
Fig. 18 · Disk Mirroring

duplicated.

Disk Mirroring

Page 26 of the Gateway S466 user manual — Parity
Page 26 · click to enlarge
Page 26

Parity generates a set of redundancy data from two or more

fully duplicate the parent data sets. In RAID, this method is

reconstruct one of the parent data sets. Parity data does not

If a single disk drive fails, it can be rebuilt from the parity

RAID level 3 combines dedicated parity with disk striping.

applied to entire drives or stripes across all disk drives in

Gateway S466 — Parity diagram (page 26)
Fig. 19 · Parity

striping. Parity provides redundancy for one drive failure

without duplicating the contents of entire disk drives, but

parity generation can slow the write process. A dedicated

Gateway S466 — Parity diagram (page 26)
Fig. 20 · Parity
Gateway S466 — Parity diagram (page 26)
Fig. 21 · Parity
Gateway S466 — Parity diagram (page 26)
Fig. 22 · Parity
Gateway S466 — Parity diagram (page 26)
Fig. 23 · Parity
Gateway S466 — Parity diagram (page 26)
Fig. 24 · Parity
Gateway S466 — Parity diagram (page 26)
Fig. 25 · Parity

The parity disk in RAID 3 is the last logical drive in a

parent data sets. The redundancy data can be used to

parity scheme during normal read/write operations is

Dedicated Parity The parity of the data on two or more disk drives is

Parity The parity data is distributed across all drives in the

RAID level 5 combines distributed parity with disk

and the data on the remaining drives.

an array. The types of parity are:

shown below:

RAID set.

Parity

Page 27 of the Gateway S466 user manual — Important
Page 27 · click to enlarge
Page 27

failed drives without system shutdown or user intervention.

the ADAC Ultra2 S466 controller assigns the hot spare that

Chapter 2 Introduction to RAID 13

A hot spare is an extra, unused disk drive that is part of the

ADAC Ultra2 S466 implements automatic and transparent

rebuilds using hot spare drives, providing a high degree of

physical drives as hot spares. When a hot spare is needed,

has a capacity closest to and at least as great as that of the

S466 RAID Management software allows you to specify

disk subsystem. It is usually in standby mode, ready for

service if a drive fails. Hot spares permit you to replace

fault tolerance and zero downtime. The ADAC Ultra2

Hot spares are only employed in arrays with redundancy, for

failed drive to take the place of the failed drive.

A hot spare connected to a specific ADAC Ultra2 S466

controller can only be used to rebuild a drive that is

example, RAID levels 1, 3, 5, 10, 30, and 50.

connected to the same controller.

Important

Hot Spares

Page 28 of the Gateway S466 user manual — Disk Rebuild
Page 28 · click to enlarge
Page 28

3, 5, 10, 30, or 50 systems. If a hot spare is not available, the failed disk drive must be replaced with a new disk drive

(RAID 1) system. If a disk drive fails, an identical drive is

immediately available. The primary data source disk drive

dedicated to rebuilding failed drives. A rebuild rate of 100

percent means the system is totally dedicated to rebuilding

between 0% and 100%. At 0%, the rebuild is only done if

the system is not doing anything else. At 100%, the rebuild

Standby (warm spare) rebuild is employed in a mirrored

A hot spare can be used to rebuild disk drives in RAID 1,

rebuild rates. If a hot spare is available, the rebuild starts

array appears to the host computer as one or more logical

You rebuild a disk drive by recreating the data that had

redundancy such as RAID level 1, 3, 5, 10, 30, and 50.

transparently rebuilds failed drives with user-definable

The ADAC Ultra2 S466 rebuild rate can be configured

governed by the RAID management software. A RAID

The ADAC Ultra2 S466 controller automatically and

automatically restarts the system and the rebuild if the

automatically when a drive fails. ADAC Ultra2 S466

Rebuild Rate The rebuild rate is the fraction of the compute cycles

Physical Array A RAID array is a collection of physical disk drives

has a higher priority than any other system activity.

so that the data on the failed drive can be rebuilt.

been stored on the drive before the drive failed.

Rebuilding can be done only in arrays with data

system goes down during a rebuild.

is the original disk drive.

the failed drive.

drives.

Disk Rebuild

Page 29 of the Gateway S466 user manual — Logical Drive
Page 29 · click to enlarge
Page 29

physical disk unit while the computer is still running. When

Chapter 2 Introduction to RAID 15

a new drive has been installed, you must issue a command

A logical drive is a partition in a physical array of disks

physical disks. A logical drive can consist of any of the

  • a combination of any two of the above conditions.

A hot swap is the manual replacement of a defective

that is made up of contiguous data segments on the

  • more than one entire physical array,
  • parts of more than one array, or
  • an entire physical array,
  • a part of an array,

to rebuild the drive.

following:

Logical Drive

Hot Swap

Page 30 of the Gateway S466 user manual — Logical Drive States
Page 30 · click to enlarge
Page 30

(READY) The drive is functioning normally but is not part of a configured

(HOTSP) The drive is powered up and ready for use as a spare in case an

Optimal The drive operating condition is good. All configured drives are

(ONLIN) The drive is functioning normally and is a part of a configured

(FAIL) A fault has occurred in the drive placing it out of service.

A SCSI disk drive can be in one of these states:

(REB) The drive is being rebuilt with data from a failed drive.

Degraded The drive operating condition is not optimal. One of the

logical drive and is not designated as a hot spare.

Offline The drive is not available to ADAC Ultra2 S466.

configured drives has failed or is offline.

Failed The drive has failed.

online drive fails.

logical drive.

Logical Drive States

SCSI Drive States

Show 8 more labels / short text on this page
State Description · State Description · online · Hot Spare · Rebuild · Online · Ready · Fail
Page 31 of the Gateway S466 user manual — Enclosure Management
Page 31 · click to enlarge
Page 31

Based The array is managed by software running in a host computer using

the parity and handle other RAID functions. A bus-based controller

Bus) but is limited to the bus it is designed for. ADAC Ultra2 S466

informed of events in the disk subsystem, such as a drive or

Chapter 2 Introduction to RAID 17

can transfer data at the speed of the host bus (PCI, ISA, EISA, VL-

Enclosure management is the intelligent monitoring of the

power supply failure. Enclosure management increases the

the host CPU bandwidth. The disadvantages associated with this

SCSI channel between the SCSI adapter and the array controller.

EISA bus) in the host computer and has its own CPU to generate

resides on a PCI bus, which can handle data transfer at up to 132

method are the load on the host CPU and the need for different

communicates with the host through a SCSI adapter in the host.

system. The disadvantage is the limited data transfer rate of the

The disk subsystem can be part of the host computer or

separate from it. Enclosure management helps you stay

SCSI to SCSI The array controller resides outside of the host computer and

transparent to the host and independent of the host operating

Bus-Based The array controller resides on the bus (for example, a PCI or

MB/s. With ADAC Ultra2 S466, the channel can handle data

The array management software runs in the controller. It is

disk subsystem by software and/or hardware.

transfer rates up to 80 MB/s per SCSI channel.

fault tolerance of the disk subsystem.

The RAID disk array types are:

software for each operating system.

Enclosure Management

Disk Array Types

Type Description · Software-

Page 32 of the Gateway S466 user manual — Enclosure Management
Page 32 · click to enlarge
Page 32
Page 32 of the Gateway S466 user manual — Enclosure Management
Page 33 of the Gateway S466 user manual — 3 RAID Levels
Page 33 · click to enlarge
Page 33

Chapter 3 RAID Levels 19

There are six official RAID levels (RAID 0 through RAID

5). ADAC Ultra2 S466 supports RAID levels 0, 1, 3, and 5. Gateway has designed three additional RAID levels (10, 30, and 50) that provide additional benefits. The RAID levels that ADAC Ultra2 S466 supports are:

Select RAID Level To ensure the best performance, you should select the

optimal RAID level when you create a system drive. The

Selecting a RAID Level The factors you need to consider when selecting a

optimal RAID level for your disk array depends on a

RAID Level Type turn to

0 Standard page 21

1 Standard page 22

3 Standard page 23

5 Standard page 25

10 ADAC Ultra2 S466 only page 26

30 ADAC Ultra2 S466 only page 27

50 ADAC Ultra2 S466 only page 28

  • the number of drives in the disk array,
  • the capacity of the drives in the array,
  • the disk performance requirements.
  • the need for data redundancy, and

RAID level are listed on the next page

3 RAID Levels

number of factors:

Page 34 of the Gateway S466 user manual — Selecting a RAID Level
Page 34 · click to enlarge
Page 34
Gateway S466 — Selecting a RAID Level diagram (page 34)
Fig. 26 · Selecting a RAID Level

complicated 4, 6, or 8 Yes

mirrored drives. High data

Selecting a RAID Level

30 Disk striping with a

10 Data striping and

50 Disk striping and

all drives.

drive.

Show 18 more labels / short text on this page
32 Yes · 32 Yes · complicated Six to · complicated Six to · More · More · More · redundancy · redundancy · redundancy · transfers, · complete · High data · transfers, · High data · transfers, · parity data across · dedicated parity
Page 35 of the Gateway S466 user manual — RAID 0
Page 35 · click to enlarge
Page 35

set during the creation of the RAID set. RAID 0 offers high

Chapter 3 RAID Levels 21

and then writes a block to each drive in the array. The size

bandwidth. By breaking up a large file into smaller blocks,

ADAC Ultra2 S466 can use several drives to read or write

of each block is determined by the stripe size parameter,

the file faster. RAID 0 involves no parity calculations to

complicate the write operation. This makes RAID 0 ideal

redundancy, but does offer the best performance of any

RAID level. RAID 0 breaks up data into smaller blocks

for applications that require high bandwidth but do not

Uses RAID 0 provides high data throughput, especially for large

files. Any environment hat does not require fault tolerance.

RAID 0 provides disk striping across all drives in the

Weak Points Does not provide fault tolerance. All data lost if any drive

RAID subsystem. RAID 0 does not provide any data

Strong Points Provides increased data throughput for large files. No

capacity loss penalty for parity.

require fault tolerance.

Drives One to 32

fails.

RAID 0

Page 36 of the Gateway S466 user manual — RAID 1
Page 36 · click to enlarge
Page 36

data redundancy, but at the cost of doubling the required

Gateway S466 — RAID 1 diagram (page 36)
Fig. 27

In RAID 1, ADAC Ultra2 S466 duplicates all data from

one drive to a second drive. RAID 1 provides complete

Weak Points RAID 1 requires twice as many disk drives. Performance is

Uses Use RAID 1 for small databases or any other environment

ideal for any application that requires fault tolerance and

Strong Points RAID 1 provides complete data redundancy. RAID 1 is

that requires fault tolerance but small capacity.

impaired during drive rebuilds.

data storage capacity.

minimal capacity.

Drives 2, 4, 6, or 8 drives.

RAID 1

Page 37 of the Gateway S466 user manual — RAID 3
Page 37 · click to enlarge
Page 37

redundancy though a dedicated parity drive. The stripe size

the array. The parity data created during the exclusive-or is

performing an exclusive-or operation on the remaining data

Chapter 3 RAID Levels 23

must be 64 KB if RAID 3 is used. RAID 3 handles data at

networks that often handle very large files, such as graphic

then written to the last drive in the array. The size of each

in the stripe and the parity for that stripe. If the failed drive

block is determined by the stripe size parameter, which is

continue as normal, except no data is written to the failed

blocks, and then writes the blocks to all but one drive in

set during the creation of the RAID set. If a single drive

drive. Reads reconstruct the data on the failed drive by

is a parity drive, writes will occur as normal, except no

calculates parity by performing an exclusive-or on the

fails, a RAID 3 array continues to operate in degraded

Weak Points The dedicated parity disk is a bottleneck with random I/O.

images. RAID 3 breaks up data into smaller blocks,

parity is written. Reads retrieve data from the disks.

Uses Best suited for applications such as graphics, imaging, or

mode. If the failed drive is a data drive, writes will

video that call for reading and writing huge, sequential

Strong Points Provides data redundancy and high data transfer rates.

RAID 3 provides disk striping and complete data

the block level, not the byte level, so it is ideal for

blocks of data.

Drives Three to eight

RAID 3

Cont’d

Page 38 of the Gateway S466 user manual — RAID 3, Continued
Page 38 · click to enlarge
Page 38
Gateway S466 — RAID 3, Continued diagram (page 38)
Fig. 28 · RAID 3, Continued

For this reason, RAID 5 is the clear choice in this scenario.

RAID 5 vs RAID 3 You may find that RAID 5 is preferable to RAID 3 even

The host attempts to make two small writes and the writes

different disk drives. Ideally both writes should take place

at the same time. But this is not possible in RAID 3, since

the writes must take turns accessing the fixed parity drive.

The benefits of RAID 3 disappear if there are many small

I/O operations scattered randomly and widely across the

becomes a bottleneck in such applications. For example:

disks in the logical drive. The RAID 3 fixed parity disk

are widely scattered, involving two different stripes and

for applications characterized by sequential reads and

writes, because ADAC Ultra2 S466 has very robust

caching algorithms.

RAID 3, Continued

Page 39 of the Gateway S466 user manual — RAID 5
Page 39 · click to enlarge
Page 39

robust caching algorithms and hardware based exclusive-or

Chapter 3 RAID Levels 25

RAID 5 includes disk striping at the byte level and parity.

operations. Since each drive contains both data and parity

drives. RAID 5 is best suited for networks that perform a

numerous writes can take place concurrently. In addition,

Uses RAID 5 provides high data throughput, especially for large

tolerance. Use for any application that has high read request

rebuilt. Environments with few processes do not perform as

In RAID 5, the parity information is written to several

RAID 5 addresses the bottleneck issue for random I/O

assist make RAID 5 performance exceptional in many

because each drive can read and write independently. If a

automation and online customer service that requires fault

Weak Points Disk drive performance will be reduced if a drive is being

files. Use RAID 5 for transaction processing applications

Strong Points Provides data redundancy and good performance in most

drive fails, ADAC Ultra2 S466 uses the parity drive to

performance gains in handling simultaneous processes.

recreate all missing information. Use also for office

well because the RAID overhead is not offset by the

lot of small I/O transactions simultaneously.

rates but low write request rates.

different environments.

Drives Three to eight

RAID 5

environments

Page 40 of the Gateway S466 user manual — RAID 10
Page 40 · click to enlarge
Page 40

data to its other drive. The size of each block is determined

drive failures while maintaining data integrity if each failed

RAID 10 is a combination of RAID 0 and RAID 1. RAID

creation of the RAID set. RAID 10 can sustain one to four

10 has mirrored drives. RAID 10 breaks up data into smaller blocks, and then stripes the blocks of data to each

RAID 1 raid set. Each RAID 1 raid set then duplicates its

environment that requires a higher degree of fault tolerance

Uses RAID 10 works best for data storage that must have 100%

Weak Points RAID 10 requires twice as many drives as all other RAID

RAID 10 works well for medium-sized databases or any

by the stripe size parameter, which is set during the

enhanced I/O performance of RAID 0 (striped arrays).

Gateway S466 — RAID 10 diagram (page 40)
Fig. 29

redundancy of mirrored arrays and that also needs the

Strong Points RAID 10 provides both high data transfer rates and

disk is in a different RAID 1 array.

and moderate to medium capacity.

Drives 2n, where n is greater than 1.

complete data redundancy.

levels except RAID 1.

RAID 10

Page 41 of the Gateway S466 user manual — RAID 30
Page 41 · click to enlarge
Page 41

data into smaller blocks, calculates parity by performing an

exclusive-or on the blocks, and then writes the blocks to all

stripe size parameter, which is set during the creation of the

Chapter 3 RAID Levels 27

RAID 30 is a combination of RAID 0 and RAID 3. RAID

disk arrays with data striped across both disk arrays. RAID

30 breaks up data into smaller blocks, and then stripes the blocks of data to each RAID 3 raid set. RAID 3 breaks up

RAID 3 array. The size of each block is determined by the

30 provides high data transfer speeds and high data reliability. RAID 30 is best implemented on two RAID 3

but one drive in the array. The parity data created during

the exclusive-or is then written to the last drive in each

press and video on demand that requires a higher degree of

RAID 30 can sustain one to four drive failures while

Uses Use RAID 30 for sequentially written and read data, pre-

maintaining data integrity if each failed disk is in a

Weak Points Requires 2 – 4 times as many parity drives as RAID 3.

Strong Points Provides data reliability and high data transfer rates.

fault tolerance and medium to large capacity.

different RAID 3 array.

RAID set.

Drives Six to 32

RAID 30

Page 42 of the Gateway S466 user manual — RAID 50
Page 42 · click to enlarge
Page 42

stripe size parameter, which is set during the creation of the

RAID 50 provides the features of both RAID 0 and RAID

5. RAID 50 includes both parity and disk striping across multiple drives. RAID 50 is best implemented on two

arrays. RAID 50 breaks up data into smaller blocks, and

then writes the blocks of data and parity to each drive in

then stripes the blocks of data to each RAID 5 raid set.

parity by performing an exclusive-or on the blocks, and

Uses RAID 50 works best when used with data that requires high

RAID 5 disk arrays with data striped across both disk

RAID 5 breaks up data into smaller blocks, calculates

the array. The size of each block is determined by the

Strong Points RAID 50 provides high data throughput, data redundancy,

RAID 50 can sustain one to four drive failures while

reliability, high request rates, and high data transfer and

maintaining data integrity if each failed disk is in a

Weak Points Requires 2 to 4 times as many parity drives as RAID 5.

and very good performance.

medium to large capacity.

different RAID 5 array.

RAID set.

Drives Six to 32

RAID 50

Page 43 of the Gateway S466 user manual — 4 ADAC Ultra2 S466 Features
Page 43 · click to enlarge
Page 43

all predictable drive failures. SMART monitors the internal

Chapter 4 Features 29

and Reporting Technology (SMART) detects up to 70% of

ADAC Ultra2 S466 controller can detect the actual RAID

configuration, maintaining the integrity of the data on each

4 ADAC Ultra2 S466 Features

intelligent PCI-to-SCSI host adapters with RAID control

capabilities. ADAC Ultra2 S466 has a SCSI channel that

supports Ultra and Wide SCSI at data transfer rates up to

Ultra2 S466. If ADAC Ultra2 S466 is replaced, the new

SMART Technology The ADAC Ultra2 S466 Self Monitoring Analysis

performance of all motors, heads, and drive electronics.

Ultra2 S466 and on the disk drives connected to ADAC

configuration information both in NVRAM on ADAC

drive, even if the drives have changed channel and/or

ADAC Ultra2 S466 is a family of high performance

80 MB/s. The SCSI channel supports up to 15 Wide devices and up to seven non-Wide devices.

Configuration on Disk Configuration on Disk (drive roaming) saves

In This Chapter Topics described in this chapter include:

  • hardware architecture features,
  • array performance features,
  • RAID management features,
  • configuration features,
  • fault tolerance features,
  • utility programs, and
  • software drivers.
  • new features,

target ID.

Page 44 of the Gateway S466 user manual — Hardware Requirements
Page 44 · click to enlarge
Page 44

5 volt PCI expansion slots. The computer must support PCI version 2.0 or later. The computer should have an Intel

Gateway S466 — Hardware Requirements diagram (page 44)
Fig. 30 · Hardware Requirements

compatible or EISA computer with a motherboard that has

Upgradable cache size 4 MB, 8 MB, 16 MB, 32 MB, 64 MB, or 128 MB

Drive interface Fast and Wide Ultra SE and LVD

Pentium, Pentium Pro, or more powerful CPU, a floppy

ADAC Ultra2 S466 can be installed in an IBM AT®-

drive, a color monitor and VGA adapter card, and a

RAID Levels 0, 1, 3, 5, 10, 30, and 50. SCSI Channels 1 Maximum number of drives per channel 15 Array interface to host PCI 2.1

Non-disk devices supported Yes

Mixed capacity hard disk drives Yes

capacities of more than 8 GB. Yes

Clustering support (Failover control) No

Online RAID level migration Yes

No reboot necessary after expansion Yes

More than 200 Qtags per physical drive Yes

Hardware clustering support on the board Yes

User-specified rebuild rate Yes

Number of 16-bit internal connectors 1 Number of 16-bit external connectors 1 Support for hard disk drives with

keyboard. A mouse is recommended.

Hardware Requirements

Configuration Features

RAID remapping Yes

Page 45 of the Gateway S466 user manual — Hardware Architecture Features
Page 45 · click to enlarge
Page 45
Gateway S466 — Hardware Architecture Features diagram (page 45)
Fig. 31 · Hardware Architecture Features
Gateway S466 — Hardware Architecture Features diagram (page 45)
Fig. 32 · Hardware Architecture Features

Chapter 4 Features 31

Host data transfer rate 132 MB/s Drive data transfer rate 80 MB/s Maximum Scatter/Gathers 26 elements Maximum size of I/O requests 6.4 MB in 64 KB stripes Maximum Queue Tags per drive 211 Stripe Sizes 2 KB, 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB

The ADAC Ultra2 S466 hardware architecture features

The ADAC Ultra2 S466 array performance features

Size of Flash ROM 1 MB Amount of NVRAM 32 KB Hardware XOR assistance No

Hardware Architecture Features

Array Performance Features

Maximum number of concurrent

include:

include:

commands 255

Page 46 of the Gateway S466 user manual — RAID Management Features
Page 46 · click to enlarge
Page 46
Gateway S466 — RAID Management Features diagram (page 46)
Fig. 33 · RAID Management Features

The ADAC Ultra2 S466 fault tolerance features include:

Enclosure management SAF-TE compliant

The ADAC Ultra2 S466 RAID management features

Drive failure detection Automatic

Drive rebuild using hot spares Automatic

Parity Generation and checking Software

Support for SMART Yes

RAID Management Features

Fault Tolerance Features

include:

Specification Feature

Page 47 of the Gateway S466 user manual — Software Utilities
Page 47 · click to enlarge
Page 47

Chapter 4 Features 33

The DOS drivers for ADAC Ultra2 S466 are contained in

the firmware on ADAC Ultra2 S466 except the DOS ASPI

The ADAC Ultra2 S466 software utility features include:

Operating System Drivers ADAC Ultra2 S466 includes a DOS software

and CD-ROM drivers. Call your Gateway OEM support

representative for information about drivers for other

Graphical user interface Yes

Bootup configuration via ADAC Configuration Manager Yes

Online Read, Write, and cache policy switching Yes

Internet and intranet support through TCP/IP Yes

configuration utility and drivers for:

Operating System Software Drivers

  • SCO UnixWare 2.1x, and
  • SCO Open Server R5.0x
  • Novell NetWare 4.x,
  • Windows NT V4.0

operating systems.

  • OS/2,

Software Utilities

Specification Feature · Management utility Yes

Page 48 of the Gateway S466 user manual — ADAC Ultra2 S466 Specifications
Page 48 · click to enlarge
Page 48

Channel Up to 15 wide or seven non-wide SCSI devices. Up

Card Size 7.375" x 4.2" (half length PCI) Processor Intel i960RP™ 32-bit RISC processor @ 33 MHz

to 6 non-disk SCSI drives per ADAC Ultra2 S466

Supported Synchronous or Asynchronous. Disk and non-disk.

RAID Levels Supported 0, 1, 3, 5,10, 30, and 50 SCSI Connectors One 68-pin internal high-density connector for 16-

Cache Configuration 4, 8, 16, 32, 64, or 128 MB through a 60 ns × 36 Fast Page Mode or EDO 72-pin SIMM.

Firmware 1 MB × 8 flash ROM Nonvolatile RAM 32 KB × 8 for storing RAID configuration Operating Voltage 5.00 V ± 0.25 V SCSI Controller One SCSI controller for Ultra and Wide support.

bit SCSI devices. One ultra-high density 68-pin

Termination Disable Automatic through cable and device detection

external connector for Ultra and Wide SCSI.

BIOS AMIBIOS ADAC Ultra2 S466 BIOS

Serial Port 9-pin RS232C-compatible berg

ADAC Ultra2 S466 Specifications

SCSI Bus LVD or single-ended

Bus Data Transfer Rate Up to 132 MB/s

Rate Up to 80 MB/s

PCI Controller Intel i960RP

controller.

Bus Type PCI 2.1

Show 5 more labels / short text on this page
Parameter Specification · SCSI Termination Active · SCSI Data Transfer · Devices per SCSI · SCSI Device Types
Page 49 of the Gateway S466 user manual — Cache Memory
Page 49 · click to enlarge
Page 49

an embedded 80960JF RISC processor running at 33 MHz.

SIMMs. Possible configurations are 4, 8, 16, 32, 64, or 128

Chapter 4 Features 35

ADAC Ultra2 S466 uses the Intel i960RP PCI bridge with

The RP bridge handles data transfers between the primary

(host) PCI bus, the secondary PCI bus, cache memory, and

performance in sequential disk accesses, the ADAC Ultra2

upgrade. The ADAC Ultra2 S466 BIOS supports INT 13h

at BIOS initialization. ADAC BIOS Setup is

the SCSI bus. The DMA controller supports chaining and

bank that uses 1 MB x 36, 4 MB x 36, 16 MB x 36, or 32

ADAC Ultra2 S466 supports write-through or write-back

S466 controller uses read-ahead caching by default. You

unaligned data transfers. The embedded 80960JF CPU

processing, SCSI bus transfers, RAID processing, drive

ADAC Ultra2 S466 cache memory resides in a memory

extensive setup utility that can be accessed by pressing

MB x 36 72-pin 60 or 70 ns Fast Page Mode or EDO

caching, selectable for each logical drive. To improve

The BIOS resides on a 1 MB × 8 flash ROM for easy

calls to boot DOS without special software or device

directs all controller functions, including command

rebuilding, cache management, and error recovery.

drivers. The ADAC Ultra2 S466 BIOS provides an

described in the ADAC Ultra2 S466 Configuration

can disable read-ahead caching.

ADAC Ultra2 S466 BIOS

Software Guide.

PCI Bridge/CPU

MB.

Cache Memory

Page 50 of the Gateway S466 user manual — Onboard Speaker
Page 50 · click to enlarge
Page 50

ADAC Ultra2 S466 has a Fast and Wide SCSI channel that

termination disable via cable detection. The SCSI channel

supports up to 15 wide or seven non-wide SCSI devices at

speeds up to 80 MB/s. ADAC Ultra2 S466 supports up to

generator for audible warnings when system errors occur.

Audible warnings can be generated through this speaker.

ADAC Ultra2 S466 includes a 9-pin RS232C-compatible

supports both LVD and single-ended devices with active

The ADAC Ultra2 S466 controller has an onboard tone

termination. Synchronous and asynchronous devices are

supported. ADAC Ultra2 S466 provides automatic

serial port berg connector, which can connect to

The audible warnings are listed on page 93.

six non-disk devices per controller.

communications devices.

Onboard Speaker

Serial Port

SCSI Bus

Page 51 of the Gateway S466 user manual — SCSI Connectors
Page 51 · click to enlarge
Page 51

Chapter 4 Features 37

Multi-threading Up to 255 simultaneous commands with elevator sorting and

Stripe Size Variable for all logical drives: 2 KB, 4 KB, 8 KB, 16 KB, 32

ADAC Ultra2 S466 uses active termination on the SCSI

The ADAC Ultra2 S466 firmware handles all RAID and

ADAC Ultra2 S466 has two types of SCSI connectors:

Both connector types can be used for the SCSI channel.

specifications. Termination enable/disable is automatic

  • a 68-pin external ultra-high-density connector.
  • a 68-pin high density internal connector and

Rebuild Multiple rebuilds and consistency checks with user-

bus conforming to Alternative 2 of the SCSI-2

SCSI command processing and also supports:

concatenation of requests per SCSI channel

Queuing Multiple tags to improve random access

Scatter/Gather Multiple address/count pairs

Reconnect Optimizes SCSI Bus seek.

KB, 64 KB, or 128 KB.

through cable detection.

definable priority.

SCSI Connectors

SCSI Termination

SCSI Firmware

Feature Description · Tagged Command · Disconnect/

Page 52 of the Gateway S466 user manual — RAID Management
Page 52 · click to enlarge
Page 52

manage and configure the RAID system and ADAC Ultra2

S466, create and manage multiple disk arrays, control and

Ultra2 S466 Configuration Software Guide for additional

configures, monitors, and maintains multiple RAID servers

ADAC Configuration Manager This is a character-based utility that works

2.x, OS/2 Warp, and Novell NetWare 3.x and 4.x. See the ADAC Ultra2 S466 Configuration Software Guide for

formats disk drives, and manages the RAID system. It is

in DOS, SCO Unix SVR3.2 R4.2, SCO UnixWare, OS/2

RAID management is provided by software utilities that

monitor multiple RAID servers, provide error statistics

logging, and provide online maintenance. They include:

ADAC BIOS Setup BIOS Setup configures and maintains RAID arrays,

ADAC Ultra2 S466 Configuration Software Guide for

independent of any operating system. See the ADAC

from any network node or a remote location. See the

Power Console Plus Power Console Plus runs in Windows NT. It

  • General Alert Module.
  • Power Console Plus,

additional information.

additional information.

  • ADAC BIOS Setup,
  • ADAC Manager

information.

RAID Management

Page 53 of the Gateway S466 user manual — Fault-Tolerance Features
Page 53 · click to enlarge
Page 53

Detect Failed Drive The ADAC Ultra2 S466 firmware automatically detects

Chapter 4 Features 39

Hot Swap ADAC Ultra2 S466 supports the manual replacement of a

disk unit in the RAID subsystem without system shutdown.

and rebuilds failed drives. This can be done transparently

  • hot swap manual replacement without bringing the

The ADAC Ultra2 S466 fault-tolerance features are:

  • SAF-TE compliant enclosure management.
  • automatic failed drive rebuild with no user
  • automatic failed drive detection,

Fault-Tolerance Features

with hot spares.

intervention required, · system down, and

Page 54 of the Gateway S466 user manual — Compatibility
Page 54 · click to enlarge
Page 54

SNMP managers and RedAlert from Storage Dimensions.

drives, CD-ROMs, tape drives, optical drives, DAT drives

Server Management As an SNMP agent, ADAC Ultra2 S466 supports all

Cheyenne®, CorelSCSI®, Arcserve®, and Novaback®.

SCSI Device Compatibility ADAC Ultra2 S466 supports SCSI hard disk

Software All SCSI backup and utility software should work with

This software is not provided with ADAC Ultra2 S466.

ADAC Ultra2 S466. Software that has been tested and

approved for use with ADAC Ultra2 S466 includes

ADAC Ultra2 S466 Features were discussed in this

ADAC Ultra2 S466 compatibility issues include:

Hardware installation is discussed in Chapter 6.

  • SCSI device compatibility, and

and other SCSI peripheral devices.

  • software compatibility
  • server management,

chapter.

Compatibility

Summary

Page 55 of the Gateway S466 user manual — S466
Page 55 · click to enlarge
Page 55

SCSI Channel Physical SCSI drives must be organized into logical drives.

Chapter 5 Configuring ADAC Ultra2 S466 41

when connecting and configuring SCSI devices in a RAID

  • attach non-disk SCSI devices to a single SCSI channel

Your ADAC Ultra2 S466 adapter has one SCSI channel.

Basic Configuration Rules You should observe the following guidelines

  • make sure any hot spare has a capacity that is at least

as large as the largest drive that may be replaced by

The arrays and logical drives that you construct must be

  • you can place up to eight physical disk drives in an
  • include all drives that have the same capacity to the

replacement drive has a capacity that is at least as

  • when replacing a failed drive, make sure that the

5 Configuring ADAC Ultra2

able to support the RAID level that you select.

that does not have any disk drives,

large as the drive being replaced.

Configuring SCSI Physical Drives

the hot spare, and

array:

S466

same array, · array,

Page 56 of the Gateway S466 user manual — LD6
Page 56 · click to enlarge
Page 56
Gateway S466 — SCSI Connectors diagram (page 56)
Fig. 34 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 56)
Fig. 35 · SCSI Connectors

Logical Drive Configuration

Current Configuration

0 1 2 3 4 5 6 8 9 10 11 12 13 14 15

LD6

LD7

LD8

Cont’d

Page 57 of the Gateway S466 user manual — Physical Device Layout
Page 57 · click to enlarge
Page 57
Gateway S466 — SCSI Connectors diagram (page 57)
Fig. 36 · SCSI Connectors

Chapter 5 Configuring ADAC Ultra2 S466 43

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

Logical Drive Number/ Drive Number

Physical Device Layout

Show 12 more labels / short text on this page
Manufacturer/Model Number · Manufacturer/Model Number · Manufacturer/Model Number · Firmware level · Firmware level · Firmware level · Device Type · Device Type · Device Type · Target ID · Target ID · Target ID
Page 58 of the Gateway S466 user manual — SCSI Connectors
Page 58 · click to enlarge
Page 58
Gateway S466 — SCSI Connectors diagram (page 58)
Fig. 37 · SCSI Connectors

Manufacturer/Model Number · Firmware level

Page 59 of the Gateway S466 user manual — Configuring Arrays
Page 59 · click to enlarge
Page 59

Chapter 5 Configuring ADAC Ultra2 S466 45

Organize the physical disk drives in arrays after the drives

initialized. Each array can consist of one to eight physical

spanned. Spanned drives can be treated as one large drive.

BIOS Setup, the ADAC Configuration Manager, or Power

are presented to the operating system. You must create one

The logical drive capacity can include all or any portion of

organization for the drive array. You must arrange arrays

Data can be striped across multiple arrays as one logical

You can create spanned drives by using the ADAC BIOS

Creating Hot Spares Any drive that is present, formatted, and initialized

Creating Logical Drives Logical drives are arrays or spanned arrays that

a array. The logical drive capacity can also be larger than

an array by using spanning. ADAC Ultra2 S466 supports

number of drives in a array determines the RAID levels

so that you can create system drives that can function as

You can sequentially arrange arrays with an identical

You can also designate drives as hot spares via ADAC

are connected to ADAC Ultra2 S466, formatted, and

ADAC Ultra2 S466 supports up to eight arrays. The

Arranging Arrays You must arrange the arrays to provide additional

number of drives so that the drives in the group are

Setup utility or the ADAC Configuration Manager.

but is not included in a array or logical drive is

automatically designated as a hot spare.

that can be supported.

or more logical drives.

up to 8 logical drives.

boot devices.

Console Plus.

disk drives.

Configuring Arrays

drive.

Page 60 of the Gateway S466 user manual — Configuration Strategies
Page 60 · click to enlarge
Page 60

logical drive configuration that maximizes one factor at the

each RAID level is shown below. OEM level firmware that

Gateway S466 — SCSI Connectors diagram (page 60)
Fig. 38 · SCSI Connectors
aredrive capacity, drive availability (fault tolerance), and

not provide data redundancy. Maximum drive capacity for

smallest disk) – (capacity of 1 disk X

smallest disk) – (capacity of 1 disk X

The most important factors in RAID array configuration

drive performance. You cannot configure a logical drive

Maximize Capacity RAID 0 achieves maximum drive capacity, but does

without parity 1 – 32 (Number of disks) X capacity of

that optimizes all three factors, but it is easy to choose a

1 Mirroring 2 (Capacity of smallest disk) X (1)

3. 8 (Number of disks) X (capacity of
3. 8 (Number of disks) X (capacity of

(Number of disks) X (capacity of

(Number of disks) X (capacity of

expense of the other two factors, although needs are

can span up to 4 logical drives is assumed.

Striping 6 – 32 (Must be a multiple

Striping 6 – 32 (Must be a multiple

seldom that simple.

Configuration Strategies

30 RAID 3 and

50 RAID 5 and

Show 5 more labels / short text on this page
Cont’d · number of Arrays) · number of Arrays) · of arrays) · of arrays)
Page 61 of the Gateway S466 user manual — Configuration Strategies, Continued
Page 61 · click to enlarge
Page 61
Gateway S466 — SCSI Connectors diagram (page 61)
Fig. 39 · SCSI Connectors

Chapter 5 Configuring ADAC Ultra2 S466 47

maximizing the level of fault tolerance. The levels of fault

performance. But optimal drive configuration for one type

Maximizing Drive Availability You can maximize the availability of data

3 100% protection through a dedicated parity drive. 5 100% protection through striping and parity. The data is striped and parity data is written across a number of physical

Maximizing Drive Performance You can configure an array for optimal

of application will probably not be optimal for any other

characteristics for RAID drive arrays at each RAID level

50 100% protection through data striping and parity. All data is striped and parity data is written across all drives in two or

0 Excellent for all types of I/O activity, but provides no data

10 100% protection through data mirroring. 30 100% protection through data striping. All data is striped across all drives in two or more arrays.

5 Provides data redundancy and good performance in most

30 Provides data redundancy and good performance in most

application. A basic guideline of the performance

10 Provides data redundancy and excellent performance.

50 Provides data redundancy and very good performance.

on the physical disk drive in the logical array by

1 Provides data redundancy and good performance.

tolerance provided by the RAID levels are:

RAID Level Performance Characteristics

Configuration Strategies, Continued

3 Provides data redundancy.

environments.

environments.

security.

is:

Page 62 of the Gateway S466 user manual — Configuring Logical Drives
Page 62 · click to enlarge
Page 62

Only one RAID level can be assigned to each logical drive.

Gateway S466 — SCSI Connectors diagram (page 62)
Fig. 40 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 62)
Fig. 41 · SCSI Connectors

After you have installed the ADAC Ultra2 S466 controller

4 Define and configure one or more logical drives. Select Easy Configuration

5 Create and configure one or more system drives (logical drives). Select the

in the server and have attached all physical disk drives,

1 Optimize the ADAC Ultra2 S466 controller options for your system. See

perform the following actions to prepare a RAID disk

2 Perform a low-level format the SCSI drives that will be included in the

in ADAC Configuration Manager or select New Configuration to

7 Initialize the system drives. After initialization, you can install the

3 Press to run the ADAC Configuration Manager.

RAID level, cache policy, read policy, and write policy.

The drives required per RAID level is:

array and the drives to be used for hot spares.

Configuring Logical Drives

Assigning RAID Levels

customize the RAID array.

6 Save the configuration.

array:

operating system.

Page 63 of the Gateway S466 user manual — Optimizing Data Storage
Page 63 · click to enlarge
Page 63

Will this disk array increase the system storage capacity for

Chapter 5 Configuring ADAC Ultra2 S466 49

Data Access Requirements Each type of data stored in the disk subsystem

has a different frequency of read and write activity. If you

write operations tend to be long. Data stored on a general-

purpose file server involves relatively short read and write

Array Functions You must first define the major purpose of the disk array.

general-purpose file and print servers? Does this disk array

successfully determine a strategy for optimizing the disk

Servers that support Video on Demand typically read the

data often, but write data infrequently. Both the read and

You must identify the purpose of the data to be stored in

the disk subsystem before you can confidently choose a

support any software system that must be available 24

hours per day? Will the information stored in this disk

available on demand? Will this disk array contain data

array contains large audio or video files that must be

subsystem capacity, availability, and performance.

know the data access requirements, you can more

RAID level and a RAID configuration.

operations with relatively small files.

from an imaging system?

Optimizing Data Storage

Page 64 of the Gateway S466 user manual — Planning the Array Configuration
Page 64 · click to enlarge
Page 64

RAID 1 and RAID 10 require 2, 4, 6, or 8 drives. RAID 30

capacity for all possible drive configurations for an array

consisting of one to eight drives. This table does not take

into account any hot spare (standby) drives. You should

Using the Array Configuration Planner The following table lists the

always have a hot spare drive in case of drive failure.

possible RAID levels, fault tolerance, and effective

Answer the following questions about this array:

Are all of the disk drives and the server protected by a UPS?

and RAID 50 require at least 6 drives.

Amount of cache memory installed on ADAC Ultra2 S466

Purpose of this array. Rank the following factors:

Planning the Array Configuration

Maximize hard drive performance and throughput

Maximize the safety of the data (fault tolerance)

Number of physical disk drives in the array

How many hot spares?

Question Answer · Maximize drive capacity

Page 65 of the Gateway S466 user manual — Array Configuration Planner
Page 65 · click to enlarge
Page 65

Chapter 5 Configuring ADAC Ultra2 S466 51

1 None Excellent No 100% 1 RAID 0 Excellent No 100% 2 None Excellent No 100% 2 RAID 0 Excellent No 100% 2 RAID 1 Good Yes 50% 3 None Excellent No 100% 3 RAID 0 Excellent No 100% 3 RAID 3 Good Yes 67% 3 RAID 5 Good Yes 67% 4 None Excellent No 100% 4 RAID 0 Excellent No 100% 4 RAID 1 Good Yes 50% 4 RAID 3 Good Yes 75% 4 RAID 5 Good Yes 75% 4 RAID 10 Good Yes 50% 5 None Excellent No 100% 5 RAID 0 Excellent No 100% 5 RAID 3 Good Yes 80% 5 RAID 5 Good Yes 80% 6 None Excellent No 100% 6 RAID 0 Excellent No 100% 6 RAID 1 Good Yes 50% 6 RAID 3 Good Yes 83% 6 RAID 5 Good Yes 83% 6 RAID 10 Good Yes 50% 6 RAID 30 Good Yes 67% 6 RAID 50 Good Yes 67% 7 None Excellent No 100% 7 RAID 0 Excellent No 100% 7 RAID 3 Good Yes 86% 7 RAID 5 Good Yes 86%

Array Configuration Planner

Show 6 more labels / short text on this page
Tolerance Effective · Capacity · Performance Fault · RAID Levels Relative · Drives Possible · Number of
Page 66 of the Gateway S466 user manual — SCSI Connectors
Page 66 · click to enlarge
Page 66
Page 66 of the Gateway S466 user manual — SCSI Connectors
Page 67 of the Gateway S466 user manual — Checklist
Page 67 · click to enlarge
Page 67
Gateway S466 — SCSI Connectors diagram (page 67)
Fig. 42 · SCSI Connectors

Optional Equipment You may also want to install SCSI cables that connect

Chapter 6 Hardware Installation 53

  • the necessary SCSI cables and terminators (this depends on
  • Fast SCSI 2 or Wide SCSI hard disk drives and other SCSI

q 5 Install the ADAC Ultra2 S466 card in the server and attach the

SCSI cables and terminators as needed. Make sure Pin 1 on the

cable matches Pin 1 on the connector. Make sure that the SCSI

attached. Make sure the ADAC card is properly installed. Turn

q 7 Install and configure the ADAC software utilities and drivers.

  • a host computer with an available PCI expansion slot,

q 3 Determine the SCSI ID and SCSI termination requirements.

the number and type of SCSI devices to be attached),

  • an Uninterruptible Power Supply (UPS) for the entire

q 1 Turn all power off to the server and all hard disk drives,

q 4 Make sure the jumper settings on the ADAC Ultra2 S466

q 6 Perform a safety check. Make sure all cables are properly

q 2 Prepare the host system. See the host system technical

q 11 Install the network operating system drivers as needed.

  • the ADAC Ultra2 S466 Installation diskettes,

ADAC Ultra2 S466 to external SCSI devices.

cables you use conform to all SCSI specifications.

6 Hardware Installation

power on after completing the safety check.

q 9 Configure system drives (logical drives).

  • a ADAC Ultra2 S466 Controller,

q 8 Format the hard disk drives as needed.

Requirements You must have the following:

q 10 Initialize the logical drives.

devices, as desired.

Checklist

system, and

Page 68 of the Gateway S466 user manual — Installation Steps
Page 68 · click to enlarge
Page 68

Ultra2 S466 settings, even custom installation can be quick

cards with resource settings that may conflict with ADAC

Gateway S466 — SCSI Connectors diagram (page 68)
Fig. 43 · SCSI Connectors

Ultra2 S466 controller. See page 57 for the ADAC

ADAC Ultra2 S466 provides extensive customization

features and your computer does not use other adapter

S466 card. 4 MB minimum cache memory is required.

options. If you need only basic ADAC Ultra2 S466

Each step is described in detail below.

9 Set the target IDs for the SCSI devices.

12 Install software drivers for the desired

and easy.

Installation Steps

operating systems.

Cont’d

Page 69 of the Gateway S466 user manual — Step 2 Power Down
Page 69 · click to enlarge
Page 69
  • the ADAC Ultra2 S466 Configuration Software Guide,

Chapter 6 Hardware Installation 55

damage. If the card appears damaged, or if any item listed

SCSI Controller. Each ADAC Ultra2 S466 card you install

representative. The ADAC Ultra2 S466 Controller is also

ADAC Ultra2 S466. ADAC Ultra2 S466 is essentially a

environment. The ADAC Ultra2 S466 controller card is

Turn off the computer and remove the cover. Make sure

will require an available PCI IRQ; make sure an IRQ is

  • the ADAC Ultra2 S466 Operating System Drivers

the computer is turned off and disconnected from any

Make sure the motherboard is configured correctly for

packed inside an anti-static bag between two sponge

sheets. Remove the controller card and inspect it for

  • the ADAC Ultra2 S466 Configuration Utilities

Unpack and install the hardware in a static-free

  • the ADAC Ultra2 S466 Hardware Guide,

networks before installing the controller card.

below is missing, contact your OEM support

available for each controller you install.

  • the so ftware license agreement,
  • the warranty registration card.

diskette for DOS, and

Step 3 Configure Motherboard

shipped with:

Step 2 Power Down

Step 1 Unpack

Guide,

Page 70 of the Gateway S466 user manual — Important
Page 70 · click to enlarge
Page 70
Gateway S466 — SCSI Connectors diagram (page 70)
Fig. 44 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 70)
Fig. 45 · SCSI Connectors

technology in the SIMM must have equal row and column

EDO SIMM EDO SIMMs are specified below. The DRAM technology

Support Bank I Total Memory

If the SIMM DRAM is not installed when you receive your ADAC Ultra2

S466 RAID controller, you must call the manufacturer for a list of approved

memory must be installed before ADAC Ultra2 S466 is operational.

Fast Page Mode SIMM FPM SIMMs are specified below. The DRAM

FPM 5 V 60ns Yes Single-sided No 4M x 36 16MB

FPM 5 V 60ns Yes Double-sided No 8M x 36 32 MB

FPM 5 V 60ns Yes Single-sided No 16M x 36 64 MB

FPM 5 V 60ns Yes Double-sided No 32M x36 128 MB

EDO 5 V 50ns Yes Single-sided No 4M x 36 16MB

EDO 5 V 50ns Yes Double-sided No 8M x 36 32 MB

EDO 5 V 50ns Yes Single-sided No 16M x 36 64 MB

EDO 5 V 50ns Yes Double-sided No 32M x36 128 MB

FPM 5 V 60ns Yes Single-sided No 1M x 36 4MB

FPM 5 V 60ns Yes Double-sided No 2M x 36 8MB

EDO 5 V 50ns Yes Single-sided No 1M x 36 4MB

EDO 5 V 50ns Yes Double-sided No 2M x 36 8MB

in the SIMM must have equal row and column size.

A minimum of 4 MB of cache memory is required. The cache

SIMM vendors. You must only use an approved SIMM.

Type Volt Speed Parity Type BBU

Important

Step 4 Install Cache Memory

size.

Cont’d · Memory

Page 71 of the Gateway S466 user manual — Supported Cache Memory Configurations
Page 71 · click to enlarge
Page 71

into place, indicating proper seating in the socket, as shown

Chapter 6 Hardware Installation 57

static-free surface and install the SIMM. The SIMM clicks

Install cache memory on the ADAC Ultra2 S466 card in

the SIMM socket. This socket accepts a 72-pin × 36 Fast

Page Mode or EDO SIMM as specified on the previous

Lay the controller card component-side up on a clean

Gateway S466 — SCSI Connectors diagram (page 71)
Fig. 46 · SCSI Connectors

4 MB Single-sided 1 MB x 36 Fast Page Mode

8 MB Double-sided 1 MB x 36 Fast Page Mode

16 MB Single-sided 4 MB x 36 Fast Page Mode

32 MB Double-sided 4 MB x 36 Fast Page Mode

64 MB Single-sided 16 MB x 36 Fast Page Mode

128 MB Double-sided 32 MB x 36 Fast Page Mode

Step 4 Install Cache Memory, Continued

Supported Cache Memory Configurations

below.

page.

Page 72 of the Gateway S466 user manual — ADAC Ultra2 S466 Card Layout
Page 72 · click to enlarge
Page 72
Gateway S466 — SCSI Connectors diagram (page 72)
Fig. 47 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 72)
Fig. 48 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 72)
Fig. 49 · SCSI Connectors

Make sure the jumper settings on the ADAC Ultra2 S466

J2 Internal SCSI Wide (16-bit) connector 68-pin connector J6 External SCSI 2 Wide (16-bit)

J1 Termination Enable Control 3-pin header J3 I2C connector 4-pin header J7 Cache memory SIMM socket 72-pin connector J4 Serial port connector 9-pin connector J8

J10 Short Pins 1-2 3-pin header J11 i960RP configuration 2-pin header J12 i960RP configuration 2-pin header

card are correct. The jumpers and connectors are:

ADAC Ultra2 S466 Card Layout

Step 5 Set Jumpers

Cont’d

Page 73 of the Gateway S466 user manual — Step 5 Set Jumpers, Continued
Page 73 · click to enlarge
Page 73
Gateway S466 — SCSI Connectors diagram (page 73)
Fig. 50 · SCSI Connectors

J4 Serial Port J4 is a 9-pin berg that attaches to a serial cable. The pinout:

Chapter 6 Hardware Installation 59

J3 I2C Interface Connector J3 is a four-pin header that allows the i960JX

Interface Unit. Attach a four-wire cable from J3 to the I2C

J1 Termination Enable J1 is a three-pin header that specifies hardware or

core processor to serve as a master and slave device that

J5 Hard Disk LED J5 is a four-pin connector that attaches to a cable that

connects to the hard disk LED mounted on the computer

Gateway S466 — SCSI Connectors diagram (page 73)
Fig. 51 · SCSI Connectors

Permanently disable all onboard SCSI termination. Short Pins 2-3

resided on the I2C bus when used with the I2C Bus

enclosure. The LED indicates data transfers.

software control of SCSI termination.

Gateway S466 — SCSI Connectors diagram (page 73)
Fig. 52 · SCSI Connectors

2 SCSI Activity Signal

3 SCSI Activity Signal

Step 5 Set Jumpers, Continued

Bus Interface Unit.

Show 4 more labels / short text on this page
Cont’d · Pin Description · 1 High · 4 High
Page 74 of the Gateway S466 user manual — Step 5 Set Jumpers, Continued
Page 74 · click to enlarge
Page 74

for normal operation (J11 and J12 OPEN). All other modes

J8, J9 J8 and J9 are 3-pin jumpers. The factory setting is Pins 1-2

J11, J12 i960RP Initialization J11 and J12 are 2-pin bergs that specify the

shorted. Pins 1-2 should always be shorted for J8 and J9.

i960RP mode when initially powered up. Mode 3 is used

0 Short Pins 1-2 Short Pins 1-2

2 OPEN Short Pins 1-2

I960RP Initialization Mode J19 Setting J22 Setting

J10 J10 is a 3-pin jumper. Make sure Pins 1-2 of J10 are

1 Short Pins 1-2 OPEN

3 OPEN OPEN

always shorted. This is the factory setting.

are used for test purposes only.

Step 5 Set Jumpers, Continued

Page 75 of the Gateway S466 user manual — Step 6 Set Termination
Page 75 · click to enlarge
Page 75

You must terminate the SCSI bus properly. Set termination

For a disk array, set SCSI bus termination so that removing

Chapter 6 Hardware Installation 61

devices. Disable termination on the SCSI devices. See the

properly to minimize reflections and losses. Termination

should be set at each end of the SCSI cable(s), as shown

configuration. However, you can override this setting by

Gateway S466 — SCSI Connectors diagram (page 75)
Fig. 53 · SCSI Connectors

or adding a SCSI device does not disturb termination. An

easy way to do this is to connect the ADAC Ultra2 S466

external terminator module at the other end of the cable.

below. Termination is always enabled, regardless of the

The connectors between the two ends can connect SCSI

card to one end of the SCSI cable and to connect an

manual for each SCSI device to disable termination.

at both ends of the SCSI cable. The SCSI bus is an

electrical transmission line and must be terminated

setting another state.

Step 6 Set Termination

Page 76 of the Gateway S466 user manual — SCSI Termination
Page 76 · click to enlarge
Page 76

termination and termination power are intact when any disk

The SCSI bus is an electrical transmission line and it must

be terminated properly to minimize reflections and losses.

You complete the SCSI bus by setting termination at both

external SCSI terminator module to the end of the cable or

Selecting a Terminator Use standard external SCSI terminators on a SCSI

Terminating Internal SCSI Disk Arrays Set the termination so that SCSI

Gateway S466 — SCSI Connectors diagram (page 76)
Fig. 54 · SCSI Connectors

by attaching a SCSI device that internally terminates the

channel operating at 10 MB/s or higher synchronous data

terminate the other end of the SCSI bus by attaching an

drive is removed from a SCSI channel, as shown below:

You can let ADAC Ultra2 S466 automatically provide

SCSI termination at one end of the SCSI bus. You can

SCSI bus at the end of the SCSI channel.

transfer.

SCSI Termination

ends.

Cont’d

Page 77 of the Gateway S466 user manual — SCSI Termination, Continued
Page 77 · click to enlarge
Page 77

Terminating External Disk Arrays In most array enclosures, the end of the

Gateway S466 — SCSI Connectors diagram (page 77)
Fig. 55 · SCSI Connectors

Chapter 6 Hardware Installation 63

termination is not disturbed when any drive is removed, as

internal and external drives with ADAC Ultra2 S466. You

still must make sure that the proper SCSI termination and

SCSI cable has an independent SCSI terminator module

that is not part of any SCSI drive. In this way, SCSI

Terminating Internal and External Disk Arrays You can use both

termination power is preserved, as shown below:

SCSI Termination, Continued

shown below:

Cont’d

Page 78 of the Gateway S466 user manual — SCSI Termination, Continued
Page 78 · click to enlarge
Page 78

have a unique SCSI ID regardless of the SCSI channel they

Make sure that no hard disk drives are attached to the same

ROM drives, and other non-disk drive devices must each

performance will be significantly degraded if SCSI hard

Gateway S466 — SCSI Connectors diagram (page 78)
Fig. 56 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 78)
Fig. 57 · SCSI Connectors

Connecting Non-Disk SCSI Devices SCSI Tape drives, scanners, CD-

RAID controller if LVD disk drives are also attached because the

are attached to. The general rule for Unix systems is:

advisable to attach a non-disk device to a ADAC Ultra2 S466

SCSI channel as the non-disk SCSI devices. Drive

Since all non-disk SCSI devices are single ended, it is not

SCSI bus will then operate in single ended mode.

disk drives are attached to this channel.

  • CD-ROM drive set to SCSI ID 5.
  • tape drive set to SCSI ID 2, and

SCSI Termination, Continued

Page 79 of the Gateway S466 user manual — Step 7 Install ADAC Ultra2 S466
Page 79 · click to enlarge
Page 79

controller card bus connector to the slot. Press down gently

Chapter 6 Hardware Installation 65

Insert the ADAC Ultra2 S466 card in a PCI slot as shown

Choose a 5 V PCI slot and align the ADAC Ultra2 S466

but firmly to make sure that the card is properly seated in

the slot. The bottom edge of the controller card should be

Gateway S466 — SCSI Connectors diagram (page 79)
Fig. 58 · SCSI Connectors
Gateway S466 — SCSI Connectors diagram (page 79)
Fig. 59 · SCSI Connectors

Screw the bracket to the computer frame.

Step 7 Install ADAC Ultra2 S466

flush with the slot.

below:

Page 80 of the Gateway S466 user manual — Step 8 Connect SCSI Cables
Page 80 · click to enlarge
Page 80
Gateway S466 — SCSI Connectors diagram (page 80)
Fig. 60 · SCSI Connectors

Connect SCSI cables to SCSI devices. ADAC Ultra2 S466

SCSI and J6, the SCSI channel external ultra high-density

devices or single ended 1.5 meters for Ultra SCSI devices. The cable length

internal high-density 68-pin connector for Wide (16-bit)

1 Disable termination on any SCSI device that does not sit at the end of the

4 The cable length should not exceed three meters for Fast SCSI (10 MB/s)

5 The cable length should not exceed six meters for non-Fast SCSI devices.

provides two SCSI connectorsJ2, the SCSI channel

68-pin connector for Wide (16-bit) SCSI.

Connect SCSI Devices When connecting SCSI devices:

3 Set proper target IDs (TIDs) for all SCSI devices.

2 Configure all SCSI devices to supply TermPWR.

can be up to 12 meters for LVD devices.

Step 8 Connect SCSI Cables

SCSI bus.

Cont’d · Step Action

Page 81 of the Gateway S466 user manual — Step 9 Set Target IDs
Page 81 · click to enlarge
Page 81

Chapter 6 Hardware Installation 67

Cable Suggestions System throughput problems can occur if SCSI cable use

  • for single ended SCSI devices, use the shortest SCSI cables

meters for an 8-drive Ultra SCSI system and no more than 3

device in a specific SCSI channel must have a unique TID

where they are connected. See the documentation for each

from 0 to 6. 16-bit devices can use the TIDs from 0 to 15.

  • do not mix cable types (choose either flat or rounded and

The arbitration priority for a SCSI device depends on its

TID 7 6 5 … 2 1 0 15 14 … 9 8

(no more than 3 meters for Fast SCSI, no more than 1.5

Set target identifiers (TIDs) on the SCSI devices. Each

should have unique SCSI IDs regardless of the channel

  • cable stub length should be no more than 0.1 meter (4

in that channel. Non-disk devices (CD-ROM or tapes)

SCSI device to set the TIDs. The ADAC Ultra2 S466

channel. Eight-bit SCSI devices can only use the TIDs

  • you can use cables up to 12 meters for LVD devices.

controller automatically occupies TID 7 in the SCSI

Non-disk devices (CD-ROM or tapes) should have unique SCSI

  • ribbon cables have fairly good cross-talk rejection

IDs regardless of the channel they are connected to.

meters for a 6-drive Ultra SCSI system),

Step 8 Connect SCSI Cables , Continued

  • avoid clustering the cable nodes,

is not maximized. You should:

shielded or non-shielded), and

  • route SCSI cables carefully,
  • use high impedance cables,
  • use active termination,

Important

characteristics.

Step 9 Set Target IDs

TID.

Priority Highest Lowest · inches),

Page 82 of the Gateway S466 user manual — Example of ADAC Ultra2 S466 ID Mapping
Page 82 · click to enlarge
Page 82

devices because they are limited to IDs 1 through 6. The

SCSI-2 ANSI specification has a limit of eight LUNs per

All logical drives on each SCSI bus are identified to the

host as ID 0. Differentiate the drives with Logical Unit

because LUNs are used to present logical drives. The

ID. The SCSI-3 specification increased the number of

Identifiers (LUNs). ID 0 cannot be used for non-disk

ADAC Ultra2 S466 is limited to eight logical drives

ID LUN Device ID LUN Device

0 0 Disk (A1-X) 1 0 Scanner

0 5 Disk (A6-X) 6 0 Optical

0 1 Disk (A2-X) 2 0 CD

0 2 Disk (A3-X) 3 0 Tape

0 3 Disk (A4-X) 4 0 CD

0 4 Disk (A5-X) 5 0 Tape

LUNs to 16. An example of ID mapping follows.

Device Identification on ADAC Ultra2 S466

Gateway S466 — Device Identification on ADAC Ultra2 S466 diagram (page 82)
Fig. 61 · Device Identification on ADAC Ultra2 S466

Example of ADAC Ultra2 S466 ID Mapping

As Presented to the Operating System

0 6 Disk (A7-X)

0 7 Disk (A8-X)

Page 83 of the Gateway S466 user manual — Step 10 Power Up
Page 83 · click to enlarge
Page 83

Chapter 6 Hardware Installation 69

power supplies so that the SCSI devices are powered up at

seconds. The ADAC Ultra2 S466 host adapter (controller)

displayed in the second portion of the BIOS message. The

numbering of the controllers follows the PCI slot scanning

Replace the computer cover and reconnect the AC power

computer is powered up before a SCSI device, the device

The firmware takes several seconds to initialize. During

this time the adapter will scan the SCSI channel. When

cords. Turn power on to the host computer. Set up the

The utility prompt times out after several

number, firmware version, and cache DRAM size are

During boot, the ADAC Ultra2 S466 BIOS message

the same time as or before the host computer. If the

0 Logical Drives found on the Host Adapter 0 Logical Drives handled by BIOS Press to run ADAC Ultra2 S466 BIOS Configuration Utility

ADAC Ultra2 S466 Disk Array Adapter BIOS Version x.xx date

Firmware Initializing... [ Scanning SCSI Device ...(etc.)... ]

Host Adapter-1 Firmware Version x.xx DRAM Size 4 MB

order used by the host motherboard.

ready, the following appears:

might not be recognized.

appears:

Step 10 Power Up

Page 84 of the Gateway S466 user manual — Step 11 Run ADAC BIOS Setup
Page 84 · click to enlarge
Page 84

ASPI Driver CorelSCSI, Novaback, and PC Tools are not provided with

See the ADAC Ultra2 S466 Configuration Software Guide

channel it resides on. SCSI IDs 1 through 6 are valid,

Drivers Devices Supported Application Software Features

Copy ADACASPI.SYS to your hard disk drive. Add the

Press to run the ADAC BIOS Setup utility.

The ADAC Ultra2 S466 ASPI driver can be used in the

  • up to six non-disk SCSI devices (each SCSI device

must use a unique SCSI ID regardless of the SCSI

  • virtual DMA services (VDS) for up to eight logical

DOS and Windows 95 environments. The DOS ASPI

Tools. VDS

/q Quiet mode. All message except error message are suppressed.

/a Physical drive ccess mode. Direct access to physical drives is

  • up to 12 ADAC Ultra2 S466 adapters, and

optical drives, etc. CorelSCSI, Novaback, PC

/v Verbose mode. All message are displayed on the screen.

for information about running BIOS Setup.

Step 12 Install Operating System Driver

Parameters The ADACASPI.SYS parameters are:

device=\ADACASPI.SYS /v

following line to CONFIG.SYS:

Step 11 Run ADAC BIOS Setup

/h INT 13h support is not provided.

ADAC Ultra2 S466.

driver supports:

ADACASPI.SYS CD-ROM, tape,

drives.

permitted.

Cont’d · Parameter Description

Page 85 of the Gateway S466 user manual — MSCDEX /D:MSCD001
Page 85 · click to enlarge
Page 85

Chapter 6 Hardware Installation 71

CD-ROM drives operating under DOS, Windows 3.x, and

The ADACASPI.SYS ASPI manager must be added to the

device driver. See the instructions on the previous page for

Add the following line to CONFIG.SYS, making sure it is

CD-ROM Driver A device driver is provided with ADAC Ultra2 S466 for

Windows 95. The driver filename is ADACDROM.SYS.

supplied with MS-DOS® and PC-DOS® Version 5.0 or

CONFIG.SYS file before you can install the CD-ROM

ADACDROM.SYS to the root directory of the C: drive.

Add the following to AUTOEXEC.BAT. Make sure it

MSCDEX is the CD-ROM drive extension file that is

Step 12 Install Operating System Driver, Continued

later. See your DOS manual for the command line

preceded by the line for ADACASPI.SYS:

adding the ADACASPI.SYS driver. Copy

precedes the SMARTDRV.EXE line.

DEVICE=C:\ADACDROM.SYS

parameters for MSCDEX.

MSCDEX /D:MSCD001

Page 86 of the Gateway S466 user manual — Summary
Page 86 · click to enlarge
Page 86

This chapter discussed hardware installation. Configure the

RAID system via software configuration utilities. See the

ADAC Ultra2 S466 Configuration Software Guide for all

information about ADAC Ultra2 S466 software utilities.

The utility programs for configuring ADAC Ultra2 S466

ADAC BIOS Setup independent of the operating system

Novell NetWare 3.x, 4.x

Power Console Plus Microsoft Windows NT,

SCO UNIX SVR3.2

Configuration Utility Operating System

are:

Summary

Show 4 more labels / short text on this page
SCO UnixWare · Windows 95 · Manager DOS · ADAC Configuration
Page 87 of the Gateway S466 user manual — 7 Troubleshooting
Page 87 · click to enlarge
Page 87

process after installation. Make sure the SCSI BIOS on the motherboard

Chapter 7 Troubleshooting 73

slot. It must be installed in the RAID Upgrade

Check the system BIOS configuration for PCI

Initialize the logical drive before installing the

If the drive continues to fail, replace the drive

Check the drives IDs on each channel to make

Check the termination. The device at the end

Set the drives to spin on command. This will

allow ADAC Ultra2 S466 to spin two devices

card is installed in the proper PCI expansion

process after installation. Make sure the ADAC Ultra2 S466 adapter

fails often Check the drive error counts using Power

with another drive with the same capacity.

should install at least 4 MB of memory in

For proper cache memory operation, you

interrupt assignments. Make sure some

These utilities require a color monitor.

sure each device has a different ID.

of the channel must be terminated.

EEPROM. You may need a new EEPROM.

Interrupts are assigned for PCI.

Replace the drive cable.

ADAC Ultra2 S466.

has been disabled.

operating system.

Format the drive.

simultaneously.

7 Troubleshooting

Console Plus.

PCI slot..

Some operating systems do not load

in a computer with a ADAC Ultra2

ADAC Ultra2 S466 using the same

ADAConf.exe does not display the

The system hangs during the boot

The system hangs during the boot

One of the hard drive in the array

ADAConf.exe and tried to make a

power supply. There is a problem

Pressing or running

ADAC Ultra2 S466 installed, the

screen display is garbled or does

new configuration. The system

hangs when scanning devices.

spinning the drives all at once.

Multiple drives connected to

At system power-up with the

Pressed . Ran

Cannot flash or update the

Management Menu.

not appear at all.

S466 adapter.

Problem Suggested Solution · Rebuild the drive

Page 88 of the Gateway S466 user manual — SCSI Connectors
Page 88 · click to enlarge
Page 88

is properly terminated using the recommended

Make sure that TERMPWR is being properly

provided to each peripheral device populated

Make sure that each end of the channel chain

terminator type for the peripheral device. The

Make sure (on a channel basis) only two type

Non-hard disk devices can only accommodate

disk devices are supported per ADAC Ultra2

get a drive assignment? To maintain the DOS Path statement integrity.

ADAC Ultra2 S466 card if only one cable is

If using an FPM SIMM, make sure the RAS

controller is properly seated in the PCI slot.

SCSI IDs 1, 2, 3, 4, 5 or 6, regardless of the

channel is automatically terminated at the

channel used. A maximum of six non-hard

of cables are connected at any one time.

Make sure that the ADAC Ultra2 S466

Access Time parameter is 70 ns.

connected to a channel.

S466 adapter.

channel.

What SCSI IDs can a non-hard disk

appears and remains on the screen.

device have and what is maximum

Why does a failed logical array still

Firmware Initializing...

number allowed per adapter?

Problem Suggested Solution

Page 89 of the Gateway S466 user manual — BIOS Boot Error Messages
Page 89 · click to enlarge
Page 89

configuration stored on the

connected and are powered

Chapter 7 Troubleshooting 75

ADAC Ultra2 S466 BIOS

Make sure ADAC Ultra2

S466 is properly installed.

Make sure ADAC Ultra2

S466 is properly installed.

Press a key to run ADAC

both the configuration in

problem by selecting one

Manager to find out if any

Message Problem Suggested Solution

Enable the BIOS via the

Configuration Manager.

disk drives. Resolve the

responding. Reconnect,

of the configurations.

sign on. Make sure all physical

physical drives are not

replace, or rebuild any

Configure menu.

drive that is not

Setup utility.

responding.

on.

the configuration stored in

in the ADAC Ultra2 S466

The ADAC Ultra2 S466

Sometimes the BIOS is

booting from the BIOS.

adapter does not match

1 Logical Drive Failed A logical drive failed to

BIOS is disabled.

xxxx Not Responding The BIOS cannot

adapter firmware.

Adapter The BIOS cannot

adapter firmware.

BIOS Boot Error Messages

the drives.

Adapter BIOS Disabled.

Host Adapter at Baseport

No ADAC Ultra2 S466

Press any key to run the

Configuration Utility.

Configuration Utility.

mismatch.

Show 17 more labels / short text on this page
Run ADAC Configuration · Configuration to examine · Configuration from the · Choose View/Add · drives are properly · NVRAM and the · Use View/Add · The configuration stored · communicate with the · communicate with the · disabled to prevent · Configuration option of · NVRAM and drives · No Logical Drives · Handled by BIOS · Configuration of · Run View/Add
Page 90 of the Gateway S466 user manual — SCSI Connectors
Page 90 · click to enlarge
Page 90

connected and are powered

connected and are powered

connected and are powered

Manager to find out if any

Make sure ADAC Ultra2

Make ADAC memory has

Message Problem Suggested Solution

responding. Reconnect,

responding. Reconnect,

S466 memory has been

been properly installed.

Make sure all physical

Manager to find if any

physical drives are not

replace, or rebuild any

in a degraded state. Make sure all physical

physical drives are not

replace, or rebuild any

Make sure the physical

properly installed.

drive that is not

drive that is not

responding.

responding.

on.

on.

on.

Degraded x number of logical drives

Not enough ADAC Ultra2

1 Logical Drive Degraded A logical drive signed on

SCSIO IDs a, b, and c are

signed on in a degraded

Insufficient Memory Not enough memory on

The physical drives with

not responding on SCSI

S466 memory to run

the ADAC adapter to

configuration.

channel x.

BIOS.

state.

run BIOS. Press any key

The following SCSI IDs

are not responding:

Channel x:a.b.c

Show 9 more labels / short text on this page
Run ADAC Configuration · Run ADAC Configuration · drives are properly · drives are properly · drives are properly · support the current · Insufficient memory to · X Logical Drives · to continue…
Page 91 of the Gateway S466 user manual — Other BIOS Error Messages
Page 91 · click to enlarge
Page 91

configuration in NVRAM and

the configuration stored on the

Chapter 7 Troubleshooting 77

Remove the drive or drives

problem by selecting one of

Message Problem Suggested Solution

Press a key to run ADAC

that should not be used.

Configuration Manager.

disk drives. Resolve the

Reconfigure the array.

to examine both the

the configurations.

Configure menu.

feature did not find the physical

and c. ADAC cannot determine

The configuration stored in the

ADAC NVRAM does not match

ID. No slot is available to map

feature found the same data on

two or more physical drive on

channel x with SCSI IDs a, b,

the drive that has the duplicate

the configuration stored on the

disk with the displayed SCSI

The physical disk roaming

cannot resolve the physical

The physical drive roaming

Other BIOS Error Messages

the physical drive. ADAC

drives into the current

configuration.

information.

drives.

Channel xa, b,

same data y, z

Show 16 more labels / short text on this page
Use View/Add Configuration · Configuration from the · Choose View/Add · slot available for · and NVRAM on · Following SCSI · Following SCSI · disk not found · and no empty · configuration · between disks · IDs have the · Unresolved · mapping it · the adapter · mismatch
Page 92 of the Gateway S466 user manual — DOS ASPI Driver Error Messages
Page 92 · click to enlarge
Page 92

error code=[0xab] Correct the condition that caused the failure. The failure

CONFIG.SYS or this driver is used with a BIOS that is

0x80 Timed out waiting for interrupt to be posted

0x81 Timed out waiting for Response command.

0x85 No adapters found or no PCI BIOS support.

during scanning. A SCSI device that is not a hard disk

drive, such as a tape drive or CD-ROM drive, must be

unique for each adapter and cannot be SCSI ID 0. The

earlier than v1.10, or no logical drives are configured.

has NOT been loaded. The ASPI manager is not loaded. One of the failure

attached to this SCSI channel. The SCSI ID must be

located The driver did not find any non-hard drive devices

0x82 Invalid command completion count.

0x83 Invalid completion status received.

0x90 Unknown Setup completion error

supported SCSI IDs are 1, 2, 3, 4, 5, and 6.

0x84 Invalid command ID received.

codes listed below is displayed next.

The /h option is appended to driver in

0x40 No ADAC adapters found

DOS ASPI Driver Error Messages

codes are:

Gateway Inc. ASPI Manager

No non-disk devices were

’ERRORVDS support is

*INACTIVE* for logical drives

Message Corrective Action · Controller setup FAILED

Page 93 of the Gateway S466 user manual — Other Potential Problems
Page 93 · click to enlarge
Page 93

Virtual Sizing The Virtual Sizing option enables RAID expansion. Virtual

Chapter 7 Troubleshooting 79

under DOS At this time, copied CDs are not accessible from DOS even

Physical Drive Errors To display the ADAC Configuration Manager Media Error

occurred while actually transferring data. An Other Error is

Multiple LUNs ADAC Ultra2 S466 supports one LUN per each target ID.

Power Requirements The maximum ADAC Ultra2 S466 power requirements are

DOS ASPI ADACASPI.SYS, the DOS ASPI manager, uses 6 KB of

device failure, poor cabling, bad termination, signal loss,

drive or add a physical drive to an existing logical drive.

BSD Unix We do not provide a driver for BSDI Unix. ADAC Ultra2

after loading ADACASPI.SYS and ADACDROM.SYS.

physical drive under the Physical Drive menu, selected

Run ADAC Configuration Manager by pressing

to enable Virtual Sizing. Select the Objects menu,

then select the Logical Drive menu. Select View/Update

from the Objects menu. A Media Error is an error that

an error that occurs at the hardware level because of a

Sizing must be enabled to increase the size of a logical

and Other Error options, press after selecting a

Parameters. Set Virtual Sizing to Enabled.

No multiple LUN devices are supported.

S466 does not support BSDI Unix.

system memory once it is loaded.

15 watts at 5V and 3 Amps.

Other Potential Problems

etc.

Topic Information · CD-ROM drives

Page 94 of the Gateway S466 user manual — SCSI Connectors
Page 94 · click to enlarge
Page 94

The characteristic impedance of the cable should be 90 +/-

6 ohms for the /REQ and /ACK signals and 90 +/- 10 ohms for all other signals.

The stub length(the distance from the controller’s external

The spacing of devices on the mainline SCSI bus should be

All signal lines shall be terminated once at both ends of the

The maximum signal path length between terminators is 3

meters when using up to 4 maximum capacitance (25 pF)

connector to the mainline SCSI bus) shall not exceed.1m

devices and 1.5 meters when using more than 4 devices.

terminators, with the end devices located as close as

SCSI devices should be uniformly spaced between

Requirements The ANSI specification dictates the following:

bus powered by the TERMPWR line.

at least three times the stub length.

possible to the terminators.

(approximately 4 inches).

Topic Information · SCSI Bus

Page 95 of the Gateway S466 user manual — SCSI Connectors
Page 95 · click to enlarge
Page 95

Chapter 7 Troubleshooting 81

devices on the ADAC Ultra2 S466 will not be recognized

supported SCSI host adapters without making the devices

until after the initial reboot. The Microsoft documented

Setup could not determine the type of one or more

list. In some cases, Windows NT Setup repeatedly

Installation When Windows NT is installed via a bootable CD, the

press to prevents Windows NT Setup from

performing disk controller detection. This allows

you to install the driver from the Drivers disk you

mass storage devices installed in your system, or

you have chosen to manually specify an adapter,

5 Insert the Drivers Disk you made when prompted

to do so and select ADAC Ultra2 S466 from this

Repeat this step for each host adapter not already

press S to display a list of supported SCSI host

To install drivers when Setup recognizes one of the

Setup is inspecting your computer’s hardware

prompts to swap disks. Windows NT will now

recognize any devices attached to this adapter.

created. All SCSI adapters must be installed

4 Select Other from the bottom of the list.

2 When Windows NT Setup displays

3. When Windows NT Setup displays

recognized by Windows NT Setup.

SETUP.TXT is on diskette 2 or the CD

1 Restart Windows NT Setup.

workaround is in SETUP.TXT:

attached to it available for use:

configuration...,

manually.

adapters.

Topic Information · Windows NT

Page 96 of the Gateway S466 user manual — SCSI Connectors
Page 96 · click to enlarge
Page 96
Page 96 of the Gateway S466 user manual — SCSI Connectors
Page 97 of the Gateway S466 user manual — SCSI Connectors
Page 97 · click to enlarge
Page 97

differebtial primary bus (P-CABLE) as specified in SCSI-3

  • flat ribbon or twisted pair cable for connecting internal
  • flat ribbon or twisted pair cable for connecting internal
  • cable assembly for converting from internal wide SCSI

Appendix A SCSI Cables and Connectors 83

The SCSI channel on the ADAC Ultra2 S466 Controller

ADAC Ultra2 S466 to wide SCSI devices. The following

connector pinouts are provided for both single-ended and

connectors to internal non-wide (Type 2) connectors,

  • cable assembly for converting from internal wide to
  • cable assembly for converting from internal wide to

ADAC Ultra2 S466 provides several different types of

Parallel Interface X3T9.2, Project 885-D, revision 12b,

internal non-wide SCSI connectors (Type 30), and

  • one 68-pin ultra high density external connector.

has a 68-pin high density 0.050 inch pitch unshielded

This connector provides all signals needed to connect

  • one 68-pin high density internal connector, and

The cable assemblies that interface with the 68-pin

68-Pin High Density SCSI Internal Connector

internal non-wide SCSI connectors.

SCSI connectors. The connectors are:

and external wide SCSI devices,

A SCSI Cables and

date July 2, 1993.

connector is:

Connectors

connector.

SCSI Connectors

Cont’d · wide SCSI devices,

Page 98 of the Gateway S466 user manual — 68-Pin High Density Connectors, Continued
Page 98 · click to enlarge
Page 98
Gateway S466 — SCSI Connectors diagram (page 98)
Fig. 62 · SCSI Connectors

Cable Assembly for Internal Wide SCSI Devices The cable assembly for

connecting internal wide SCSI devices is shown below:

68-Pin High Density Connectors, Continued

Cont’d

Page 99 of the Gateway S466 user manual — 68 Conductor 0.025 Centerline 30 AWG
Page 99 · click to enlarge
Page 99

connecting internal wide and external wide SCSI devices is

Appendix A SCSI Cables and Connectors 85

Connecting Internal and External Wide Devices The cable assembly for

NOTE: To convert to 2-56 holes, use screwlock

A

B

B

kit 749087-1, 749087-2, or 750644-1

Cable: Flat Ribbon or Twisted-Pair Flat Cable

Connector A: 68 position panel mount receptacle

Gateway S466 — NOTE: To convert to 2-56 holes, use screwlock diagram (page 99)
Fig. 63 · NOTE: To convert to 2-56 holes, use screwlock

68 Conductor 0.025 Centerline 30 AWG

68-Pin High Density Connectors, Continued

with 4-40 holes (female)

Connector B: 68 position plug (male)

AMP - 786096-7

AMP - 786090-7

from AMP

shown below:

Cont’d

Page 100 of the Gateway S466 user manual — 68-Pin High Density Connectors, Continued
Page 100 · click to enlarge
Page 100
Gateway S466 — SCSI Connectors diagram (page 100)
Fig. 64 · SCSI Connectors

assembly for converting internal wide SCSI connectors to

Converting Internal Wide to Internal Non-Wide (Type 2) The cable

internal non-wide SCSI connectors is shown below:

68-Pin High Density Connectors, Continued

Gateway S466 — 68-Pin High Density Connectors, Continued diagram (page 100)
Fig. 65 · 68-Pin High Density Connectors, Continued

Cont’d

Page 101 of the Gateway S466 user manual — AMP - 749925-5
Page 101 · click to enlarge
Page 101

Appendix A SCSI Cables and Connectors 87

Converting Internal Wide to Internal Non-Wide (Type 30) The cable

assembly for connecting internal wide SCSI devices to

B

A

internal non-wide SCSI devices is shown below:

Gateway S466 — B diagram (page 101)
Fig. 66

Laminated Discrete Wire Cable

68-Pin High Density Connectors, Continued

WireTwisted-Pair Flat Cable or
Connector A68 position plug (male)

25 pair 0.050 centerline 28 AWG

Connector B:50 position plug (male)

AMP - 749925-5

AMP - 749925-3

Cont’d

Page 102 of the Gateway S466 user manual — SCSI Connector Vendors
Page 102 · click to enlarge
Page 102

Converting from Internal Wide to Internal Non-Wide (Type 3) The cable

Gateway S466 — SCSI Connectors diagram (page 102)
Fig. 67 · SCSI Connectors

internal non-wide (Type 3) SCSI devices is shown below:

Manufacturer Connector Part Number Back Shell Part Number

assembly for connecting internal wide SCSI devices to

AMP 749111-4 749193-1 Fujitsu FCN-237R050-G/F FCN-230C050-D/E

Cables To Go Voice800-826-7904 Fax: 800-331-2841

68-Pin High Density Connectors, Continued

System Connection Voice800-877-1985
Technical Cable Concepts Voice714-835-1081
GWC Voice818-579-0888

SCSI Connector Vendors

SCSI Cable Vendors

Honda PCS-XE50MA PCS-E50LA · Manufacturer Telephone Number

Page 103 of the Gateway S466 user manual — High-Density 68-Pin SCSI Connector Pinout
Page 103 · click to enlarge
Page 103
Gateway S466 — SCSI Connectors diagram (page 103)
Fig. 68 · SCSI Connectors

Appendix A SCSI Cables and Connectors 89

Ground 33 65 66 67 -DB(10)

Ground 34 67 68 68 -DB(11)

Ground 28 55 56 62 -C/D

Ground 29 57 58 63 -REQ

Ground 31 61 62 65 -DB(8)

Ground 32 63 64 66 -DB(9)

Ground 30 59 60 64 -I/O

High-Density 68-Pin SCSI Connector Pinout

Cont’d

Page 104 of the Gateway S466 user manual — Caution
Page 104 · click to enlarge
Page 104

when using 0.025 inch centerline flat ribbon cable with

  • A hyphen before a signal name indicates that signal is
  • Eight-bit devices connected to the P-Cable must leave

High-Density Single Ended Connector The following applies to the high-

  • The connector pin refers to the conductor position

a high-density connector (AMPLIMITE.050 Series

the following signals open-DB (8), -DB (9), -DB

(10), -DB (11), -DB(12), -DB (13), -DB (14), -DB

15), and -DB (P1). • All other signals should be connected as defined.

density SCSI connector table on the previous page:

Lines labeled RESERVED should be connected to Ground

in the bus terminator assemblies or in the end devices on the

RESERVED lines should be open in the other SCSI

devices, but can be connected to Ground.

68-Pin SCSI Connector Pinout, Continued

SCSI cable.

Caution

connectors).

active low.

Page 105 of the Gateway S466 user manual — +C/D 28 55 56 62 -C/D
Page 105 · click to enlarge
Page 105
Gateway S466 — SCSI Connectors diagram (page 105)
Fig. 69 · SCSI Connectors

Appendix A SCSI Cables and Connectors 91

+REQ 29 57 58 63 -REQ

+DB(8) 31 61 62 65 -DB(8)

+DB(9) 32 63 64 66 -DB(9)

+DB(10) 33 65 66 67 -DB(10)

+DB(11) 34 67 68 68 -DB(11)

+C/D 28 55 56 62 -C/D

+I/O 30 59 60 64 -I/O

68-Pin Connector Pinout for LVD SCSI

when using flat-ribbon cable.

Page 106 of the Gateway S466 user manual — SCSI Connectors
Page 106 · click to enlarge
Page 106
Page 106 of the Gateway S466 user manual — SCSI Connectors
Page 107 of the Gateway S466 user manual — Important
Page 107 · click to enlarge
Page 107

Appendix B Audible Warnings 93

The ADAC Ultra2 S466 RAID controller has an onboard

offline. One or more drives in a RAID

Two or more drives in a RAID

While you were away from the

system, a disk drive in a RAID

1, 3, or 5 configuration failed. One second on

1, 3, or 5 configuration failed and was rebuilt.

One drive in a RAID 3 or 5

The audible warning were not enabled at the time this manual

0 configuration failed.

tone generator that indicates events and errors.

Tone Pattern Meaning Examples

configuration failed.

B Audible Warnings

went to press.

Important

A logical drive is

A logical drive is

been completed.

mode.

Show 11 more labels / short text on this page
running in degraded · initiated rebuild has · An automatically · Three seconds on · and three seconds · and one second · and one second · One second on · off · off · off
Page 108 of the Gateway S466 user manual — SCSI Connectors
Page 108 · click to enlarge
Page 108
Page 108 of the Gateway S466 user manual — SCSI Connectors
Page 109 of the Gateway S466 user manual — SCSI Connectors
Page 109 · click to enlarge
Page 109
Page 109 of the Gateway S466 user manual — SCSI Connectors
Page 110 of the Gateway S466 user manual — SCSI Connectors
Page 110 · click to enlarge
Page 110
Page 110 of the Gateway S466 user manual — SCSI Connectors
Page 111 of the Gateway S466 user manual — SCSI Connectors
Page 111 · click to enlarge
Page 111
Page 111 of the Gateway S466 user manual — SCSI Connectors
Page 112 of the Gateway S466 user manual — SCSI Connectors
Page 112 · click to enlarge
Page 112
Page 112 of the Gateway S466 user manual — SCSI Connectors
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The system hangs during the boot process after installation.Make sure the SCSI BIOS on the motherboard has been disabled. p.87
The system hangs during the boot process after installation.Make sure the ADAC Ultra2 S466 adapter card is installed in the proper PCI expansion slot. It must be installed in the RAID Upgrade PCI slot.. p.87
Some operating systems do not load in a computer with a ADAC Ultra2 S466 adapter.Check the system BIOS configuration for PCI interrupt assignments. Make sure some Interrupts are assigned for PCI. Initialize the logical drive before installing the operating system. p.87
The ADAC Ultra2 S466 BIOS is disabled. Sometimes the BIOS is disabled to prevent booting from the BIOS.Enable the BIOS via the ADAC Ultra2 S466 BIOS Setup utility. p.89
The BIOS cannot communicate with the adapter firmware.Make sure ADAC Ultra2 S466 is properly installed. p.89
x number of logical drives signed on in a degraded state.Make sure all physical drives are properly connected and are powered on. Run ADAC Configuration Manager to find if any physical drives are not responding. Reconnect, replace, or rebuild any drive that is not responding. p.90
The physical disk roaming feature did not find the physical disk with the displayed SCSI ID. No slot is available to map the physical drive. ADAC cannot resolve the physical drives into the current configuration.Reconfigure the array. p.91

Ask about the Gateway S466

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gateway S466

Be the first to ask — other owners or our team will answer.

Original document

Gateway S466 manual PDF

112 pages·2.3 MB·Computer Hardware·PDF
Click any page above to open it here
Page 1 / …
100%