8503624 A MAN US ADAC U2 S466 GDE R0 8/14/98
Single Ended and Low-
PCI RAID Controller
ADAC Ultra2 S466
Hardware Guide

language or computer language, or transmitted in any form whatsoever without the prior written
this publication can be reproduced, transcribed, stored in a retrieval system, translated into any
consent of the publisher, Gateway, Inc. Gateway, Inc. acknowledges the following trademarks:
IBM, AT, VGA, PS/2, and OS/2 are registered trademarks and XT and CGA are trademarks of
This publication contains proprietary information which is protected by copyright. No part of
MS-DOS, and Microsoft are registered trademarks of Microsoft Corporation. Windows 95,
SCO, UnixWare, and Unix are registered trademarks of the Santa Cruz Operation. Inc.
Microsoft Windows and Windows NT are trademarks of Microsoft Corporation.
Hewlett-Packard is a registered trademark of Hewlett-Packard Corporation.
Novell NetWare is a registered trademark of Novell Corporation.
NEC is a registered trademark of Nippon Electric Corporation.
Siemens is a registered trademark of Siemens Corporation.
Intel is a registered trademark of Intel Corporation.
International Business Machines Corporation.
AMP is a trademark of AMP Corporation.
ADAC Ultra2 S466 Hardware Guide ii
© Copyright 1998 Gateway, Inc.
6/8/98 Initial release.
All rights reserved.









The ADAC Ultra2 S466 PCI RAID Controller supports all single
Gateway’s discretion according to the terms and conditions of the
damage, direct, incidental or consequential resulting from the use
with the product). No action or proceeding against Gateway may
be commenced more than two years after the delivery of product
Licensee agrees to defend and indemnify Gateway from any and
all claims, suits, and liabilities (including attorney’s fees) arising
out of or resulting from any actual or alleged act or omission on
agents, in connection with the distribution of Licensed Software
use of Licensee’s product not caused solely by faults in Licensed
Limitations of Liability Gateway, Inc. shall in no event be held liable for any loss,
indirect, incidental, or consequential (whether arising from the
design or use of this product or the support materials provided
the part of Licensee, its authorized third parties, employees, or
liability for bodily or other injuries to end-users resulting from
ended and low-voltage differential (LVD) SCSI devices on an
Ultra and Wide SCSI channel with data transfer rates up to 80
MB/s (Megabytes per second). This manual describes ADAC
Gateway is only obligated to repair or replace this product at
expenses, or damages of any kind whatsoever, whether direct,
to end-users, including, without limitation, claims, suits, and
Limited Warranty The buyer agrees if this product proves to be defective, that
Gateway shall not be liable in tort or contract for any loss or
of this product. Please see the Warranty Registration Card
warranty registration card that accompanies this product.
shipped with this product for full warranty details.
Software as provided by Gateway to Licensee.
to Licensee of Licensed Software.
Ultra2 S466.
Cont’d · Preface vii

Brochure that was included with your system. Before you
Technical Support If you need help installing, configuring, or running the
Gateway OEM Technical Support representative. For the
Web Site We invite you to access the Gateway world wide web site
call, please complete the ADAC Ultra2 S466 Problem
ADAC Ultra2 S466 PCI RAID Controller, call your
current number, refer to the Assistance Resources
Report form on the next page.
Package Contents You should have received:
ADAC Ultra2 S466 Hardware Guide viii
at:
Guide,


Policy # of Physical
Steps necessary to re-create problem:
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8


Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number
ADAC Ultra2 S466 Hardware Guide x


Preface xi · Manufacturer/Model Number · Firmware level

exemplary, consequential or otherwise, that may result from such
any kind, either expressed or implied, including, but not limited
Ultra2 S466 Disk Array Controller. Although efforts have been
made to assure the accuracy of the information contained here,
information, and for damages, whether direct, indirect, special,
from the use or misuse of the manual or information contained
therein (even if Gateway has been advised of the possibility of
document or its contents should be addressed to Gateway at the
warranties or the limitation or exclusion of liability for indirect,
certain transactions; therefore, this statement may not apply to
error, including but not limited to the loss of profits resulting
Gateway provides this publication “as is” without warranty of
information herein; these changes will be incorporated in new
editions of the publication. Gateway may make improvements
Disclaimer This manual describes the operation of the Gateway ADAC
to, the implied warranties of merchantability or fitness for a
special, exemplary, incidental or consequential damages in
Requests for technical information about Gateway products
Gateway expressly disclaims liability for any error in this
such damages). Any questions or comments regarding this
Some states do not allow disclaimer of express or implied
typographical errors. Changes are periodically made to the
This publication could include technical inaccuracies or
and/or revisions in the product(s) and/or the program(s)
you. Also, you may have other rights which vary from
should be made to your Gateway representative.
described in this publication at any time.
address shown on the cover.
jurisdiction to jurisdiction.
ADAC Ultra2 S466 Hardware Guide xii
specific purpose.

This device complies with Part 15 of the FCC Rules. Operation is subject to
interference in a residential installation. This equipment generates, uses and
by the party responsible for compliance could void the user’s authority
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
interference to radio or television reception, which can be determined by
turning the equipment off and on, try to correct the interference by one or
interference, and (2) this device must accept any interference received,
occur in a specific installation. If this equipment does cause harmful
limits are designed to provide reasonable protection against harmful
can radiate radio frequency energy and, if not installed and used in
including interference that may cause undesired operation.
that to which the receiver is connected.
compliance with the Class B FCC limits.
more of the following measures:
to operate the equipment.
the receiver.
for help.
Preface xiii

Gateway only certifies that this product will work correctly when this
Gateway Compatibility Report for this product. Call your Gateway
sales representative for a copy of the Compatibility Report for this
product is used with the same jumper settings, the same system
peripherals that were tested by Gateway with this product. The
complete list of tested jumper settings, system configurations,
peripheral devices, and memory modules are documented in the
configuration, the same memory module parts, and the same
product.
ADAC Ultra2 S466 Hardware Guide xiv

disk subsystem management. The ADAC Ultra2 S466 is an
and Wide SCSI channel supporting data transfer rates up to
EDO DRAM cache memory in a SIMM socket used for read
SCSI Channel The ADAC Ultra2 S466 upgrade card includes one Fast-20
SCSI channel. The channel is powered by a Symbios Logic
Chapter 1 Overview 1
entry level-to mid-range RAID controller solution. ADAC
external connector for external storage subsystem and one
provides reliability, high performance, and fault-tolerant
80 Megabytes per second (MB/s) per channel. The SCSI channel supports up to fifteen non-Ultra SCSI devices.
The ADAC Ultra2 S466 PCI RAID controller is a high
RAID in a server. The ADAC Ultra2 S466 has an Ultra
performance intelligent PCI-to-SCSI host adapter with
Ultra2 S466 offers a cost-effective way to implement
and write-back caching and RAID 5 parity generation.
NVRAM and Flash ROM A 32 KB x 8 NVRAM stores RAID system
SCSI Connectors ADAC Ultra2 S466 has one ultra high density 68-pin
RAID control capabilities. The ADAC Ultra2 S466
configuration information. The ADAC Ultra2 S466
firmware is stored in flash ROM for easy upgrade.
ADAC Ultra2 S466 Features ADAC Ultra2 S466 features:
preserving existing PCI-SCSI software,
high density 68-pin internal connector.
53C895 (Fast-40) SCSI processor.
and routing and


SCSI Standard SCSI Bus Width SCSI Throughput
SCSI I 8 bits 5 MB/s Fast SCSI 8 bits 10 MB/s Fast Wide SCSI 16 bits 20 MB/s Ultra SCSI 8 bits 20 MB/s Wide Ultra SCSI 16 bits 40 MB/s Ultra 2 SCSI 8 bits 40 MB/s Wide Ultra 2 SCSI 16 bits 80 MB/s
The SCSI standard defines two electrical buses:
SCSI I 6 m 12 m 7 Fast SCSI 6 m 12 m 7 Fast Wide SCSI 6 m 12 m 15 Ultra SCSI 1.5 m 12 m 7 Ultra SCSI 3 m 12 m 3 Wide Ultra SCSI 12 m 15 Wide Ultra SCSI 1.5 m 12 m 7 Wide Ultra SCSI 3 m 12 m 3 Ultra 2 SCSI 25 m 1 Ultra 2 SCSI 12 m 7 Wide Ultra 2 SCSI 25 m 1 Wide Ultra 2 SCSI 12 m 15
Single Ended and Differential SCSI Buses

Chapter 1 Overview 3
overview, RAID planning, and RAID system configuration
ADAC Ultra2 S466 Operating System Drivers Guide This manual provides
ADAC Ultra2 S466 Configuration Software Guide This manual describes
information you will need first. Read the ADAC Ultra2
detailed information about installing the ADAC Ultra2
the software configuration utilities that configure and
The ADAC Ultra2 S466 documentation set includes:
Using ADAC Ultra2 S466 Manuals This manual contains the RAID
S466 operating system drivers.
S466 Hardware Guide first.
modify RAID systems.












Improved I/O Although disk drive capabilities have improved drastically,
Chapter 2 Introduction to RAID 5
RAID (Redundant Array of Independent Disks) is an array
of multiple independent hard disk drives that provide high
single drive. The RAID array appears to the host computer
computers. Data loss because of a disk drive failure can be
management software configures and monitors RAID disk
generate more noise and vibration than electronic devices.
These factors reduce the reliability of data stored on disks.
performance and fault tolerance. A RAID disk subsystem
improves I/O performance over a computer using only a
as a single storage unit or as multiple logical units. I/O is
performance, and increases storage subsystem reliability.
RAID provides data security through fault tolerance and
actual performance has improved only three to four times
in the last decade. Computing performance has improved
subsystem operate more slowly, require more power, and
reliability and fault tolerance compared to single-drive
RAID has gained popularity because it: improves I/O
simultaneously. RAID systems improve data storage
recovered by reconstructing missing data from the
Increased Reliability The electromechanical components of a disk
expedited because several disks can be accessed
redundant data storage. The ADAC Ultra2 S466
over 50 times during the same time period.
remaining data and parity drives.
arrays.



intelligence on an adapter card that is installed in a network
Chapter 2 Introduction to RAID 7
performance. ADAC Ultra2 S466 is part of the file server,
so it can transmit data directly across the computer’s buses
The available sequential data transfer rate is determined by
SCSI-to-SCSI A SCSI-to-SCSI RAID product puts the RAID intelligence
In SCSI-to-SCSI RAID products, the hard drive subsystem
The ADAC Ultra2 S466 controller is a host-based RAID
solution. ADAC Ultra2 S466 is a PCI adapter card that is
Adapter installed in the network server. The data transfer
uses only a single SCSI ID, which allows you to connect
rate is limited to the bandwidth of the SCSI channel. A
installed in any available PCI expansion slot in a host
SCSI-to-SCSI RAID product that has two wide SCSI
multiple drive subsystems to a single SCSI controller.
server. A host-based RAID product provides the best
Host-based solutions must provide operating system-
inside the RAID chassis and uses a plain SCSI Host
squeeze the data into a single wide SCSI (40 MB/s)
channels that operate at speeds up to 80 MB/s must
Host-Based A host-based RAID product puts all of the RAID
at data transfer speeds up to 132 MB/s.
channel back to the host computer.
RAID products are either:
the following factors:
specific drivers.
system.
PCI bridge, · PCI bus,

10, 30, and 50, special RAID versions supported by ADAC Ultra2 S466.
ensuring the reliability and stability of data stored on large
disk subsystems. A RAID system can be implemented in a
supplies, and the ability to hot swap drives. ADAC Ultra2
S466 provides hot swapping through the hot spare feature.
S466 supports all standard RAID levels and RAID levels
redundant data in an array. For example, in a system with
dedicated parity, checking consistency means computing
the parity of the data drives and comparing the results to
A hot spare drive is an unused online available drive that
ADAC Ultra2 S466 instantly plugs into the system when
After the hot spare is automatically moved into the RAID
Fault tolerance is achieved through cooling fans, power
subsystem, the failed drive is automatically rebuilt. The
collection of specifications that describe a system for
standard RAID levels are 0, 1, 3, and 5. ADAC Ultra2
In RAID, check consistency verifies the correctness of
RAID disk array continues to handle request while the
RAID (Redundant Array of Independent Disks) is a
number of different versions (or RAID Levels). The
the contents of the dedicated parity drive.
an active drive fails.
rebuild occurs.
Fault Tolerance
RAID Overview



Disk striping writes data across multiple disk drives instead
repeated sequential manner. The combined storage space is
accessed simultaneously; but disk striping does not provide
drives. ADAC Ultra2 S466 supports stripe sizes of 2 KB, 4
Chapter 2 Introduction to RAID 9
supports stripe sizes of 2 KB, 4 KB, 8 KB, 16 KB, 32 KB,
For example, in a four-disk system using only disk striping
of just one disk drive. Disk striping involves partitioning
each drive storage space into stripes that can vary in size
from 2 KB to 128 KB. These stripes are interleaved in a
composed of stripes from each drive. ADAC Ultra2 S466
where striping is implemented. For example, a four-disk
segments that ADAC Ultra2 S466 writes across multiple
Stripe Width Stripe width is the number of disks involved in an array
segment 2 is written to disk 2, and so on. Disk striping
(as in RAID level 0), segment 1 is written to disk 1,
enhances performance because multiple drives are
Stripe Size The stripe size is the length of the interleaved data
array with disk striping has a stripe width of four.
KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB.
64 KB, or 128 KB.
data redundancy.


Disk spanning allows multiple disk drives to function like
one big drive. Spanning overcomes lack of disk space and
Spanning alone does not provide reliability or performance
enhancements. Spanned logical drives must have the same
resources or adding relatively inexpensive resources. For
10 Configure RAID 10 by spanning two contiguous RAID 1 logical drives.
30 Configure RAID 30 by spanning two contiguous RAID 3 logical drives.
50 Configure RAID 50 by spanning two contiguous RAID 5 logical drives.
RAID level or add fault tolerance. It does increase the size of the logical
volume and improves performance by doubling the number of spindles.
simplifies storage management by combining existing
example, four 400 MB disk drives can be combined to
appear to the operating system as one single 1600 MB
graphic, RAID 1 array is turned into a RAID 10 array.
stripe size and must be contiguous. In the following
The RAID 1 logical drives must have the same stripe size.
The RAID 3 logical drives must have the same stripe size.
The RAID 5 logical drives must have the same stripe size.
drive.
Level Description

drive is simultaneously written to another disk drive. If one
used to run the system and reconstruct the failed drive. The
100% data redundancy. Since the contents of the disk drive are completely written to a second drive, it does not matter
Chapter 2 Introduction to RAID 11
With mirroring (used in RAID 1), data written to one disk
disk drive fails, the contents of the other disk drive can be
if one of the drives fails. Both drives contain the same data
at all times. Either drive can act as the operational drive.
primary advantage of disk mirroring is that it provides
expensive because each drive in the system must be
Disk mirroring provides 100% redundancy, but is

duplicated.

Parity generates a set of redundancy data from two or more
fully duplicate the parent data sets. In RAID, this method is
reconstruct one of the parent data sets. Parity data does not
If a single disk drive fails, it can be rebuilt from the parity
RAID level 3 combines dedicated parity with disk striping.
applied to entire drives or stripes across all disk drives in

striping. Parity provides redundancy for one drive failure
without duplicating the contents of entire disk drives, but
parity generation can slow the write process. A dedicated






The parity disk in RAID 3 is the last logical drive in a
parent data sets. The redundancy data can be used to
parity scheme during normal read/write operations is
Dedicated Parity The parity of the data on two or more disk drives is
Parity The parity data is distributed across all drives in the
RAID level 5 combines distributed parity with disk
and the data on the remaining drives.
an array. The types of parity are:
shown below:
RAID set.

failed drives without system shutdown or user intervention.
the ADAC Ultra2 S466 controller assigns the hot spare that
Chapter 2 Introduction to RAID 13
A hot spare is an extra, unused disk drive that is part of the
ADAC Ultra2 S466 implements automatic and transparent
rebuilds using hot spare drives, providing a high degree of
physical drives as hot spares. When a hot spare is needed,
has a capacity closest to and at least as great as that of the
S466 RAID Management software allows you to specify
disk subsystem. It is usually in standby mode, ready for
service if a drive fails. Hot spares permit you to replace
fault tolerance and zero downtime. The ADAC Ultra2
Hot spares are only employed in arrays with redundancy, for
failed drive to take the place of the failed drive.
A hot spare connected to a specific ADAC Ultra2 S466
controller can only be used to rebuild a drive that is
example, RAID levels 1, 3, 5, 10, 30, and 50.
connected to the same controller.
Hot Spares

3, 5, 10, 30, or 50 systems. If a hot spare is not available, the failed disk drive must be replaced with a new disk drive
(RAID 1) system. If a disk drive fails, an identical drive is
immediately available. The primary data source disk drive
dedicated to rebuilding failed drives. A rebuild rate of 100
percent means the system is totally dedicated to rebuilding
between 0% and 100%. At 0%, the rebuild is only done if
the system is not doing anything else. At 100%, the rebuild
Standby (warm spare) rebuild is employed in a mirrored
A hot spare can be used to rebuild disk drives in RAID 1,
rebuild rates. If a hot spare is available, the rebuild starts
array appears to the host computer as one or more logical
You rebuild a disk drive by recreating the data that had
redundancy such as RAID level 1, 3, 5, 10, 30, and 50.
transparently rebuilds failed drives with user-definable
The ADAC Ultra2 S466 rebuild rate can be configured
governed by the RAID management software. A RAID
The ADAC Ultra2 S466 controller automatically and
automatically restarts the system and the rebuild if the
automatically when a drive fails. ADAC Ultra2 S466
Rebuild Rate The rebuild rate is the fraction of the compute cycles
Physical Array A RAID array is a collection of physical disk drives
has a higher priority than any other system activity.
so that the data on the failed drive can be rebuilt.
been stored on the drive before the drive failed.
Rebuilding can be done only in arrays with data
system goes down during a rebuild.
is the original disk drive.
the failed drive.
drives.

physical disk unit while the computer is still running. When
Chapter 2 Introduction to RAID 15
a new drive has been installed, you must issue a command
A logical drive is a partition in a physical array of disks
physical disks. A logical drive can consist of any of the
A hot swap is the manual replacement of a defective
that is made up of contiguous data segments on the
to rebuild the drive.
following:
Hot Swap

(READY) The drive is functioning normally but is not part of a configured
(HOTSP) The drive is powered up and ready for use as a spare in case an
Optimal The drive operating condition is good. All configured drives are
(ONLIN) The drive is functioning normally and is a part of a configured
(FAIL) A fault has occurred in the drive placing it out of service.
A SCSI disk drive can be in one of these states:
(REB) The drive is being rebuilt with data from a failed drive.
Degraded The drive operating condition is not optimal. One of the
logical drive and is not designated as a hot spare.
Offline The drive is not available to ADAC Ultra2 S466.
configured drives has failed or is offline.
Failed The drive has failed.
online drive fails.
logical drive.
SCSI Drive States

Based The array is managed by software running in a host computer using
the parity and handle other RAID functions. A bus-based controller
Bus) but is limited to the bus it is designed for. ADAC Ultra2 S466
informed of events in the disk subsystem, such as a drive or
Chapter 2 Introduction to RAID 17
can transfer data at the speed of the host bus (PCI, ISA, EISA, VL-
Enclosure management is the intelligent monitoring of the
power supply failure. Enclosure management increases the
the host CPU bandwidth. The disadvantages associated with this
SCSI channel between the SCSI adapter and the array controller.
EISA bus) in the host computer and has its own CPU to generate
resides on a PCI bus, which can handle data transfer at up to 132
method are the load on the host CPU and the need for different
communicates with the host through a SCSI adapter in the host.
system. The disadvantage is the limited data transfer rate of the
The disk subsystem can be part of the host computer or
separate from it. Enclosure management helps you stay
SCSI to SCSI The array controller resides outside of the host computer and
transparent to the host and independent of the host operating
Bus-Based The array controller resides on the bus (for example, a PCI or
MB/s. With ADAC Ultra2 S466, the channel can handle data
The array management software runs in the controller. It is
disk subsystem by software and/or hardware.
transfer rates up to 80 MB/s per SCSI channel.
fault tolerance of the disk subsystem.
The RAID disk array types are:
software for each operating system.
Disk Array Types
Type Description · Software-



Chapter 3 RAID Levels 19
There are six official RAID levels (RAID 0 through RAID
5). ADAC Ultra2 S466 supports RAID levels 0, 1, 3, and 5. Gateway has designed three additional RAID levels (10, 30, and 50) that provide additional benefits. The RAID levels that ADAC Ultra2 S466 supports are:
Select RAID Level To ensure the best performance, you should select the
optimal RAID level when you create a system drive. The
Selecting a RAID Level The factors you need to consider when selecting a
optimal RAID level for your disk array depends on a
RAID Level Type turn to
0 Standard page 21
1 Standard page 22
3 Standard page 23
5 Standard page 25
10 ADAC Ultra2 S466 only page 26
30 ADAC Ultra2 S466 only page 27
50 ADAC Ultra2 S466 only page 28
RAID level are listed on the next page
number of factors:


complicated 4, 6, or 8 Yes
mirrored drives. High data
30 Disk striping with a
10 Data striping and
50 Disk striping and
all drives.
drive.

set during the creation of the RAID set. RAID 0 offers high
Chapter 3 RAID Levels 21
and then writes a block to each drive in the array. The size
bandwidth. By breaking up a large file into smaller blocks,
ADAC Ultra2 S466 can use several drives to read or write
of each block is determined by the stripe size parameter,
the file faster. RAID 0 involves no parity calculations to
complicate the write operation. This makes RAID 0 ideal
redundancy, but does offer the best performance of any
RAID level. RAID 0 breaks up data into smaller blocks
for applications that require high bandwidth but do not
Uses RAID 0 provides high data throughput, especially for large
files. Any environment hat does not require fault tolerance.
RAID 0 provides disk striping across all drives in the
Weak Points Does not provide fault tolerance. All data lost if any drive
RAID subsystem. RAID 0 does not provide any data
Strong Points Provides increased data throughput for large files. No
capacity loss penalty for parity.
require fault tolerance.
Drives One to 32
fails.

data redundancy, but at the cost of doubling the required

In RAID 1, ADAC Ultra2 S466 duplicates all data from
one drive to a second drive. RAID 1 provides complete
Weak Points RAID 1 requires twice as many disk drives. Performance is
Uses Use RAID 1 for small databases or any other environment
ideal for any application that requires fault tolerance and
Strong Points RAID 1 provides complete data redundancy. RAID 1 is
that requires fault tolerance but small capacity.
impaired during drive rebuilds.
data storage capacity.
minimal capacity.
Drives 2, 4, 6, or 8 drives.

redundancy though a dedicated parity drive. The stripe size
the array. The parity data created during the exclusive-or is
performing an exclusive-or operation on the remaining data
Chapter 3 RAID Levels 23
must be 64 KB if RAID 3 is used. RAID 3 handles data at
networks that often handle very large files, such as graphic
then written to the last drive in the array. The size of each
in the stripe and the parity for that stripe. If the failed drive
block is determined by the stripe size parameter, which is
continue as normal, except no data is written to the failed
blocks, and then writes the blocks to all but one drive in
set during the creation of the RAID set. If a single drive
drive. Reads reconstruct the data on the failed drive by
is a parity drive, writes will occur as normal, except no
calculates parity by performing an exclusive-or on the
fails, a RAID 3 array continues to operate in degraded
Weak Points The dedicated parity disk is a bottleneck with random I/O.
images. RAID 3 breaks up data into smaller blocks,
parity is written. Reads retrieve data from the disks.
Uses Best suited for applications such as graphics, imaging, or
mode. If the failed drive is a data drive, writes will
video that call for reading and writing huge, sequential
Strong Points Provides data redundancy and high data transfer rates.
RAID 3 provides disk striping and complete data
the block level, not the byte level, so it is ideal for
blocks of data.
Drives Three to eight
Cont’d


For this reason, RAID 5 is the clear choice in this scenario.
RAID 5 vs RAID 3 You may find that RAID 5 is preferable to RAID 3 even
The host attempts to make two small writes and the writes
different disk drives. Ideally both writes should take place
at the same time. But this is not possible in RAID 3, since
the writes must take turns accessing the fixed parity drive.
The benefits of RAID 3 disappear if there are many small
I/O operations scattered randomly and widely across the
becomes a bottleneck in such applications. For example:
disks in the logical drive. The RAID 3 fixed parity disk
are widely scattered, involving two different stripes and
for applications characterized by sequential reads and
writes, because ADAC Ultra2 S466 has very robust
caching algorithms.

robust caching algorithms and hardware based exclusive-or
Chapter 3 RAID Levels 25
RAID 5 includes disk striping at the byte level and parity.
operations. Since each drive contains both data and parity
drives. RAID 5 is best suited for networks that perform a
numerous writes can take place concurrently. In addition,
Uses RAID 5 provides high data throughput, especially for large
tolerance. Use for any application that has high read request
rebuilt. Environments with few processes do not perform as
In RAID 5, the parity information is written to several
RAID 5 addresses the bottleneck issue for random I/O
assist make RAID 5 performance exceptional in many
because each drive can read and write independently. If a
automation and online customer service that requires fault
Weak Points Disk drive performance will be reduced if a drive is being
files. Use RAID 5 for transaction processing applications
Strong Points Provides data redundancy and good performance in most
drive fails, ADAC Ultra2 S466 uses the parity drive to
performance gains in handling simultaneous processes.
recreate all missing information. Use also for office
well because the RAID overhead is not offset by the
lot of small I/O transactions simultaneously.
rates but low write request rates.
different environments.
Drives Three to eight
environments

data to its other drive. The size of each block is determined
drive failures while maintaining data integrity if each failed
RAID 10 is a combination of RAID 0 and RAID 1. RAID
creation of the RAID set. RAID 10 can sustain one to four
10 has mirrored drives. RAID 10 breaks up data into smaller blocks, and then stripes the blocks of data to each
RAID 1 raid set. Each RAID 1 raid set then duplicates its
environment that requires a higher degree of fault tolerance
Uses RAID 10 works best for data storage that must have 100%
Weak Points RAID 10 requires twice as many drives as all other RAID
RAID 10 works well for medium-sized databases or any
by the stripe size parameter, which is set during the
enhanced I/O performance of RAID 0 (striped arrays).

redundancy of mirrored arrays and that also needs the
Strong Points RAID 10 provides both high data transfer rates and
disk is in a different RAID 1 array.
and moderate to medium capacity.
Drives 2n, where n is greater than 1.
complete data redundancy.
levels except RAID 1.

data into smaller blocks, calculates parity by performing an
exclusive-or on the blocks, and then writes the blocks to all
stripe size parameter, which is set during the creation of the
Chapter 3 RAID Levels 27
RAID 30 is a combination of RAID 0 and RAID 3. RAID
disk arrays with data striped across both disk arrays. RAID
30 breaks up data into smaller blocks, and then stripes the blocks of data to each RAID 3 raid set. RAID 3 breaks up
RAID 3 array. The size of each block is determined by the
30 provides high data transfer speeds and high data reliability. RAID 30 is best implemented on two RAID 3
but one drive in the array. The parity data created during
the exclusive-or is then written to the last drive in each
press and video on demand that requires a higher degree of
RAID 30 can sustain one to four drive failures while
Uses Use RAID 30 for sequentially written and read data, pre-
maintaining data integrity if each failed disk is in a
Weak Points Requires 2 – 4 times as many parity drives as RAID 3.
Strong Points Provides data reliability and high data transfer rates.
fault tolerance and medium to large capacity.
different RAID 3 array.
RAID set.
Drives Six to 32

stripe size parameter, which is set during the creation of the
RAID 50 provides the features of both RAID 0 and RAID
arrays. RAID 50 breaks up data into smaller blocks, and
then writes the blocks of data and parity to each drive in
then stripes the blocks of data to each RAID 5 raid set.
parity by performing an exclusive-or on the blocks, and
Uses RAID 50 works best when used with data that requires high
RAID 5 disk arrays with data striped across both disk
RAID 5 breaks up data into smaller blocks, calculates
the array. The size of each block is determined by the
Strong Points RAID 50 provides high data throughput, data redundancy,
RAID 50 can sustain one to four drive failures while
reliability, high request rates, and high data transfer and
maintaining data integrity if each failed disk is in a
Weak Points Requires 2 to 4 times as many parity drives as RAID 5.
and very good performance.
medium to large capacity.
different RAID 5 array.
RAID set.
Drives Six to 32

all predictable drive failures. SMART monitors the internal
Chapter 4 Features 29
and Reporting Technology (SMART) detects up to 70% of
ADAC Ultra2 S466 controller can detect the actual RAID
configuration, maintaining the integrity of the data on each
intelligent PCI-to-SCSI host adapters with RAID control
capabilities. ADAC Ultra2 S466 has a SCSI channel that
supports Ultra and Wide SCSI at data transfer rates up to
Ultra2 S466. If ADAC Ultra2 S466 is replaced, the new
SMART Technology The ADAC Ultra2 S466 Self Monitoring Analysis
performance of all motors, heads, and drive electronics.
Ultra2 S466 and on the disk drives connected to ADAC
configuration information both in NVRAM on ADAC
drive, even if the drives have changed channel and/or
ADAC Ultra2 S466 is a family of high performance
80 MB/s. The SCSI channel supports up to 15 Wide devices and up to seven non-Wide devices.
Configuration on Disk Configuration on Disk (drive roaming) saves
In This Chapter Topics described in this chapter include:
target ID.

5 volt PCI expansion slots. The computer must support PCI version 2.0 or later. The computer should have an Intel

compatible or EISA computer with a motherboard that has
Upgradable cache size 4 MB, 8 MB, 16 MB, 32 MB, 64 MB, or 128 MB
Drive interface Fast and Wide Ultra SE and LVD
Pentium, Pentium Pro, or more powerful CPU, a floppy
ADAC Ultra2 S466 can be installed in an IBM AT®-
drive, a color monitor and VGA adapter card, and a
RAID Levels 0, 1, 3, 5, 10, 30, and 50. SCSI Channels 1 Maximum number of drives per channel 15 Array interface to host PCI 2.1
Non-disk devices supported Yes
Mixed capacity hard disk drives Yes
capacities of more than 8 GB. Yes
Clustering support (Failover control) No
Online RAID level migration Yes
No reboot necessary after expansion Yes
More than 200 Qtags per physical drive Yes
Hardware clustering support on the board Yes
User-specified rebuild rate Yes
Number of 16-bit internal connectors 1 Number of 16-bit external connectors 1 Support for hard disk drives with
keyboard. A mouse is recommended.
Configuration Features
RAID remapping Yes



Chapter 4 Features 31
Host data transfer rate 132 MB/s Drive data transfer rate 80 MB/s Maximum Scatter/Gathers 26 elements Maximum size of I/O requests 6.4 MB in 64 KB stripes Maximum Queue Tags per drive 211 Stripe Sizes 2 KB, 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB
The ADAC Ultra2 S466 hardware architecture features
The ADAC Ultra2 S466 array performance features
Size of Flash ROM 1 MB Amount of NVRAM 32 KB Hardware XOR assistance No
Array Performance Features
Maximum number of concurrent
include:
include:
commands 255


The ADAC Ultra2 S466 fault tolerance features include:
Enclosure management SAF-TE compliant
The ADAC Ultra2 S466 RAID management features
Drive failure detection Automatic
Drive rebuild using hot spares Automatic
Parity Generation and checking Software
Support for SMART Yes
Fault Tolerance Features
include:
Specification Feature

Chapter 4 Features 33
The DOS drivers for ADAC Ultra2 S466 are contained in
the firmware on ADAC Ultra2 S466 except the DOS ASPI
The ADAC Ultra2 S466 software utility features include:
Operating System Drivers ADAC Ultra2 S466 includes a DOS software
and CD-ROM drivers. Call your Gateway OEM support
representative for information about drivers for other
Graphical user interface Yes
Bootup configuration via ADAC Configuration Manager Yes
Online Read, Write, and cache policy switching Yes
Internet and intranet support through TCP/IP Yes
configuration utility and drivers for:
operating systems.
Specification Feature · Management utility Yes

Channel Up to 15 wide or seven non-wide SCSI devices. Up
Card Size 7.375" x 4.2" (half length PCI) Processor Intel i960RP™ 32-bit RISC processor @ 33 MHz
to 6 non-disk SCSI drives per ADAC Ultra2 S466
Supported Synchronous or Asynchronous. Disk and non-disk.
RAID Levels Supported 0, 1, 3, 5,10, 30, and 50 SCSI Connectors One 68-pin internal high-density connector for 16-
Cache Configuration 4, 8, 16, 32, 64, or 128 MB through a 60 ns × 36 Fast Page Mode or EDO 72-pin SIMM.
Firmware 1 MB × 8 flash ROM Nonvolatile RAM 32 KB × 8 for storing RAID configuration Operating Voltage 5.00 V ± 0.25 V SCSI Controller One SCSI controller for Ultra and Wide support.
bit SCSI devices. One ultra-high density 68-pin
Termination Disable Automatic through cable and device detection
external connector for Ultra and Wide SCSI.
BIOS AMIBIOS ADAC Ultra2 S466 BIOS
Serial Port 9-pin RS232C-compatible berg
SCSI Bus LVD or single-ended
Bus Data Transfer Rate Up to 132 MB/s
Rate Up to 80 MB/s
PCI Controller Intel i960RP
controller.
Bus Type PCI 2.1

an embedded 80960JF RISC processor running at 33 MHz.
SIMMs. Possible configurations are 4, 8, 16, 32, 64, or 128
Chapter 4 Features 35
ADAC Ultra2 S466 uses the Intel i960RP PCI bridge with
The RP bridge handles data transfers between the primary
(host) PCI bus, the secondary PCI bus, cache memory, and
performance in sequential disk accesses, the ADAC Ultra2
upgrade. The ADAC Ultra2 S466 BIOS supports INT 13h
at BIOS initialization. ADAC BIOS Setup is
the SCSI bus. The DMA controller supports chaining and
bank that uses 1 MB x 36, 4 MB x 36, 16 MB x 36, or 32
ADAC Ultra2 S466 supports write-through or write-back
S466 controller uses read-ahead caching by default. You
unaligned data transfers. The embedded 80960JF CPU
processing, SCSI bus transfers, RAID processing, drive
ADAC Ultra2 S466 cache memory resides in a memory
extensive setup utility that can be accessed by pressing
MB x 36 72-pin 60 or 70 ns Fast Page Mode or EDO
caching, selectable for each logical drive. To improve
The BIOS resides on a 1 MB × 8 flash ROM for easy
calls to boot DOS without special software or device
directs all controller functions, including command
rebuilding, cache management, and error recovery.
drivers. The ADAC Ultra2 S466 BIOS provides an
described in the ADAC Ultra2 S466 Configuration
can disable read-ahead caching.
Software Guide.
MB.

ADAC Ultra2 S466 has a Fast and Wide SCSI channel that
termination disable via cable detection. The SCSI channel
supports up to 15 wide or seven non-wide SCSI devices at
speeds up to 80 MB/s. ADAC Ultra2 S466 supports up to
generator for audible warnings when system errors occur.
Audible warnings can be generated through this speaker.
ADAC Ultra2 S466 includes a 9-pin RS232C-compatible
supports both LVD and single-ended devices with active
The ADAC Ultra2 S466 controller has an onboard tone
termination. Synchronous and asynchronous devices are
supported. ADAC Ultra2 S466 provides automatic
serial port berg connector, which can connect to
The audible warnings are listed on page 93.
six non-disk devices per controller.
communications devices.
Serial Port
SCSI Bus

Chapter 4 Features 37
Multi-threading Up to 255 simultaneous commands with elevator sorting and
Stripe Size Variable for all logical drives: 2 KB, 4 KB, 8 KB, 16 KB, 32
ADAC Ultra2 S466 uses active termination on the SCSI
The ADAC Ultra2 S466 firmware handles all RAID and
ADAC Ultra2 S466 has two types of SCSI connectors:
Both connector types can be used for the SCSI channel.
specifications. Termination enable/disable is automatic
Rebuild Multiple rebuilds and consistency checks with user-
bus conforming to Alternative 2 of the SCSI-2
SCSI command processing and also supports:
concatenation of requests per SCSI channel
Queuing Multiple tags to improve random access
Scatter/Gather Multiple address/count pairs
Reconnect Optimizes SCSI Bus seek.
KB, 64 KB, or 128 KB.
through cable detection.
definable priority.
SCSI Termination
SCSI Firmware
Feature Description · Tagged Command · Disconnect/

manage and configure the RAID system and ADAC Ultra2
S466, create and manage multiple disk arrays, control and
Ultra2 S466 Configuration Software Guide for additional
configures, monitors, and maintains multiple RAID servers
ADAC Configuration Manager This is a character-based utility that works
2.x, OS/2 Warp, and Novell NetWare 3.x and 4.x. See the ADAC Ultra2 S466 Configuration Software Guide for
formats disk drives, and manages the RAID system. It is
in DOS, SCO Unix SVR3.2 R4.2, SCO UnixWare, OS/2
RAID management is provided by software utilities that
monitor multiple RAID servers, provide error statistics
logging, and provide online maintenance. They include:
ADAC BIOS Setup BIOS Setup configures and maintains RAID arrays,
ADAC Ultra2 S466 Configuration Software Guide for
independent of any operating system. See the ADAC
from any network node or a remote location. See the
Power Console Plus Power Console Plus runs in Windows NT. It
additional information.
additional information.
information.

Detect Failed Drive The ADAC Ultra2 S466 firmware automatically detects
Chapter 4 Features 39
Hot Swap ADAC Ultra2 S466 supports the manual replacement of a
disk unit in the RAID subsystem without system shutdown.
and rebuilds failed drives. This can be done transparently
The ADAC Ultra2 S466 fault-tolerance features are:
with hot spares.
intervention required, · system down, and

SNMP managers and RedAlert from Storage Dimensions.
drives, CD-ROMs, tape drives, optical drives, DAT drives
Server Management As an SNMP agent, ADAC Ultra2 S466 supports all
Cheyenne®, CorelSCSI®, Arcserve®, and Novaback®.
SCSI Device Compatibility ADAC Ultra2 S466 supports SCSI hard disk
Software All SCSI backup and utility software should work with
This software is not provided with ADAC Ultra2 S466.
ADAC Ultra2 S466. Software that has been tested and
approved for use with ADAC Ultra2 S466 includes
ADAC Ultra2 S466 Features were discussed in this
ADAC Ultra2 S466 compatibility issues include:
Hardware installation is discussed in Chapter 6.
and other SCSI peripheral devices.
chapter.
Summary

SCSI Channel Physical SCSI drives must be organized into logical drives.
Chapter 5 Configuring ADAC Ultra2 S466 41
when connecting and configuring SCSI devices in a RAID
Your ADAC Ultra2 S466 adapter has one SCSI channel.
Basic Configuration Rules You should observe the following guidelines
as large as the largest drive that may be replaced by
The arrays and logical drives that you construct must be
replacement drive has a capacity that is at least as
able to support the RAID level that you select.
that does not have any disk drives,
large as the drive being replaced.
the hot spare, and
array:
same array, · array,



Current Configuration
0 1 2 3 4 5 6 8 9 10 11 12 13 14 15
LD7
LD8
Cont’d


Chapter 5 Configuring ADAC Ultra2 S466 43
Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number
Logical Drive Number/ Drive Number


Manufacturer/Model Number · Firmware level

Chapter 5 Configuring ADAC Ultra2 S466 45
Organize the physical disk drives in arrays after the drives
initialized. Each array can consist of one to eight physical
spanned. Spanned drives can be treated as one large drive.
BIOS Setup, the ADAC Configuration Manager, or Power
are presented to the operating system. You must create one
The logical drive capacity can include all or any portion of
organization for the drive array. You must arrange arrays
Data can be striped across multiple arrays as one logical
You can create spanned drives by using the ADAC BIOS
Creating Hot Spares Any drive that is present, formatted, and initialized
Creating Logical Drives Logical drives are arrays or spanned arrays that
a array. The logical drive capacity can also be larger than
an array by using spanning. ADAC Ultra2 S466 supports
number of drives in a array determines the RAID levels
so that you can create system drives that can function as
You can sequentially arrange arrays with an identical
You can also designate drives as hot spares via ADAC
are connected to ADAC Ultra2 S466, formatted, and
ADAC Ultra2 S466 supports up to eight arrays. The
Arranging Arrays You must arrange the arrays to provide additional
number of drives so that the drives in the group are
Setup utility or the ADAC Configuration Manager.
but is not included in a array or logical drive is
automatically designated as a hot spare.
that can be supported.
or more logical drives.
up to 8 logical drives.
boot devices.
Console Plus.
disk drives.
drive.

logical drive configuration that maximizes one factor at the
each RAID level is shown below. OEM level firmware that

not provide data redundancy. Maximum drive capacity for
smallest disk) – (capacity of 1 disk X
smallest disk) – (capacity of 1 disk X
The most important factors in RAID array configuration
drive performance. You cannot configure a logical drive
Maximize Capacity RAID 0 achieves maximum drive capacity, but does
without parity 1 – 32 (Number of disks) X capacity of
that optimizes all three factors, but it is easy to choose a
1 Mirroring 2 (Capacity of smallest disk) X (1)
(Number of disks) X (capacity of
(Number of disks) X (capacity of
expense of the other two factors, although needs are
can span up to 4 logical drives is assumed.
Striping 6 – 32 (Must be a multiple
Striping 6 – 32 (Must be a multiple
seldom that simple.
30 RAID 3 and
50 RAID 5 and


Chapter 5 Configuring ADAC Ultra2 S466 47
maximizing the level of fault tolerance. The levels of fault
performance. But optimal drive configuration for one type
Maximizing Drive Availability You can maximize the availability of data
3 100% protection through a dedicated parity drive. 5 100% protection through striping and parity. The data is striped and parity data is written across a number of physical
Maximizing Drive Performance You can configure an array for optimal
of application will probably not be optimal for any other
characteristics for RAID drive arrays at each RAID level
50 100% protection through data striping and parity. All data is striped and parity data is written across all drives in two or
0 Excellent for all types of I/O activity, but provides no data
10 100% protection through data mirroring. 30 100% protection through data striping. All data is striped across all drives in two or more arrays.
5 Provides data redundancy and good performance in most
30 Provides data redundancy and good performance in most
application. A basic guideline of the performance
10 Provides data redundancy and excellent performance.
50 Provides data redundancy and very good performance.
on the physical disk drive in the logical array by
1 Provides data redundancy and good performance.
tolerance provided by the RAID levels are:
RAID Level Performance Characteristics
3 Provides data redundancy.
environments.
environments.
security.
is:

Only one RAID level can be assigned to each logical drive.


After you have installed the ADAC Ultra2 S466 controller
4 Define and configure one or more logical drives. Select Easy Configuration
5 Create and configure one or more system drives (logical drives). Select the
in the server and have attached all physical disk drives,
1 Optimize the ADAC Ultra2 S466 controller options for your system. See
perform the following actions to prepare a RAID disk
2 Perform a low-level format the SCSI drives that will be included in the
in ADAC Configuration Manager or select New Configuration to
7 Initialize the system drives. After initialization, you can install the
3 Press to run the ADAC Configuration Manager.
RAID level, cache policy, read policy, and write policy.
The drives required per RAID level is:
array and the drives to be used for hot spares.
Assigning RAID Levels
customize the RAID array.
6 Save the configuration.
array:
operating system.

Will this disk array increase the system storage capacity for
Chapter 5 Configuring ADAC Ultra2 S466 49
Data Access Requirements Each type of data stored in the disk subsystem
has a different frequency of read and write activity. If you
write operations tend to be long. Data stored on a general-
purpose file server involves relatively short read and write
Array Functions You must first define the major purpose of the disk array.
general-purpose file and print servers? Does this disk array
successfully determine a strategy for optimizing the disk
Servers that support Video on Demand typically read the
data often, but write data infrequently. Both the read and
You must identify the purpose of the data to be stored in
the disk subsystem before you can confidently choose a
support any software system that must be available 24
hours per day? Will the information stored in this disk
available on demand? Will this disk array contain data
array contains large audio or video files that must be
subsystem capacity, availability, and performance.
know the data access requirements, you can more
RAID level and a RAID configuration.
operations with relatively small files.
from an imaging system?

RAID 1 and RAID 10 require 2, 4, 6, or 8 drives. RAID 30
capacity for all possible drive configurations for an array
consisting of one to eight drives. This table does not take
into account any hot spare (standby) drives. You should
Using the Array Configuration Planner The following table lists the
always have a hot spare drive in case of drive failure.
possible RAID levels, fault tolerance, and effective
Answer the following questions about this array:
Are all of the disk drives and the server protected by a UPS?
and RAID 50 require at least 6 drives.
Amount of cache memory installed on ADAC Ultra2 S466
Purpose of this array. Rank the following factors:
Maximize hard drive performance and throughput
Maximize the safety of the data (fault tolerance)
Number of physical disk drives in the array
How many hot spares?
Question Answer · Maximize drive capacity

Chapter 5 Configuring ADAC Ultra2 S466 51
1 None Excellent No 100% 1 RAID 0 Excellent No 100% 2 None Excellent No 100% 2 RAID 0 Excellent No 100% 2 RAID 1 Good Yes 50% 3 None Excellent No 100% 3 RAID 0 Excellent No 100% 3 RAID 3 Good Yes 67% 3 RAID 5 Good Yes 67% 4 None Excellent No 100% 4 RAID 0 Excellent No 100% 4 RAID 1 Good Yes 50% 4 RAID 3 Good Yes 75% 4 RAID 5 Good Yes 75% 4 RAID 10 Good Yes 50% 5 None Excellent No 100% 5 RAID 0 Excellent No 100% 5 RAID 3 Good Yes 80% 5 RAID 5 Good Yes 80% 6 None Excellent No 100% 6 RAID 0 Excellent No 100% 6 RAID 1 Good Yes 50% 6 RAID 3 Good Yes 83% 6 RAID 5 Good Yes 83% 6 RAID 10 Good Yes 50% 6 RAID 30 Good Yes 67% 6 RAID 50 Good Yes 67% 7 None Excellent No 100% 7 RAID 0 Excellent No 100% 7 RAID 3 Good Yes 86% 7 RAID 5 Good Yes 86%




Optional Equipment You may also want to install SCSI cables that connect
Chapter 6 Hardware Installation 53
q 5 Install the ADAC Ultra2 S466 card in the server and attach the
SCSI cables and terminators as needed. Make sure Pin 1 on the
cable matches Pin 1 on the connector. Make sure that the SCSI
attached. Make sure the ADAC card is properly installed. Turn
q 7 Install and configure the ADAC software utilities and drivers.
q 3 Determine the SCSI ID and SCSI termination requirements.
the number and type of SCSI devices to be attached),
q 1 Turn all power off to the server and all hard disk drives,
q 6 Perform a safety check. Make sure all cables are properly
q 2 Prepare the host system. See the host system technical
q 11 Install the network operating system drivers as needed.
ADAC Ultra2 S466 to external SCSI devices.
cables you use conform to all SCSI specifications.
power on after completing the safety check.
q 9 Configure system drives (logical drives).
q 8 Format the hard disk drives as needed.
Requirements You must have the following:
q 10 Initialize the logical drives.
devices, as desired.
system, and

Ultra2 S466 settings, even custom installation can be quick
cards with resource settings that may conflict with ADAC

Ultra2 S466 controller. See page 57 for the ADAC
ADAC Ultra2 S466 provides extensive customization
features and your computer does not use other adapter
S466 card. 4 MB minimum cache memory is required.
options. If you need only basic ADAC Ultra2 S466
Each step is described in detail below.
9 Set the target IDs for the SCSI devices.
12 Install software drivers for the desired
and easy.
operating systems.
Cont’d

Chapter 6 Hardware Installation 55
damage. If the card appears damaged, or if any item listed
SCSI Controller. Each ADAC Ultra2 S466 card you install
representative. The ADAC Ultra2 S466 Controller is also
ADAC Ultra2 S466. ADAC Ultra2 S466 is essentially a
environment. The ADAC Ultra2 S466 controller card is
Turn off the computer and remove the cover. Make sure
will require an available PCI IRQ; make sure an IRQ is
the computer is turned off and disconnected from any
Make sure the motherboard is configured correctly for
packed inside an anti-static bag between two sponge
sheets. Remove the controller card and inspect it for
Unpack and install the hardware in a static-free
networks before installing the controller card.
below is missing, contact your OEM support
available for each controller you install.
diskette for DOS, and
shipped with:
Step 1 Unpack
Guide,



technology in the SIMM must have equal row and column
EDO SIMM EDO SIMMs are specified below. The DRAM technology
Support Bank I Total Memory
If the SIMM DRAM is not installed when you receive your ADAC Ultra2
S466 RAID controller, you must call the manufacturer for a list of approved
memory must be installed before ADAC Ultra2 S466 is operational.
Fast Page Mode SIMM FPM SIMMs are specified below. The DRAM
FPM 5 V 60ns Yes Single-sided No 4M x 36 16MB
FPM 5 V 60ns Yes Double-sided No 8M x 36 32 MB
FPM 5 V 60ns Yes Single-sided No 16M x 36 64 MB
FPM 5 V 60ns Yes Double-sided No 32M x36 128 MB
EDO 5 V 50ns Yes Single-sided No 4M x 36 16MB
EDO 5 V 50ns Yes Double-sided No 8M x 36 32 MB
EDO 5 V 50ns Yes Single-sided No 16M x 36 64 MB
EDO 5 V 50ns Yes Double-sided No 32M x36 128 MB
FPM 5 V 60ns Yes Single-sided No 1M x 36 4MB
FPM 5 V 60ns Yes Double-sided No 2M x 36 8MB
EDO 5 V 50ns Yes Single-sided No 1M x 36 4MB
EDO 5 V 50ns Yes Double-sided No 2M x 36 8MB
in the SIMM must have equal row and column size.
A minimum of 4 MB of cache memory is required. The cache
SIMM vendors. You must only use an approved SIMM.
Type Volt Speed Parity Type BBU
Step 4 Install Cache Memory
size.
Cont’d · Memory

into place, indicating proper seating in the socket, as shown
Chapter 6 Hardware Installation 57
static-free surface and install the SIMM. The SIMM clicks
Install cache memory on the ADAC Ultra2 S466 card in
the SIMM socket. This socket accepts a 72-pin × 36 Fast
Page Mode or EDO SIMM as specified on the previous
Lay the controller card component-side up on a clean

4 MB Single-sided 1 MB x 36 Fast Page Mode
8 MB Double-sided 1 MB x 36 Fast Page Mode
16 MB Single-sided 4 MB x 36 Fast Page Mode
32 MB Double-sided 4 MB x 36 Fast Page Mode
64 MB Single-sided 16 MB x 36 Fast Page Mode
128 MB Double-sided 32 MB x 36 Fast Page Mode
below.
page.




Make sure the jumper settings on the ADAC Ultra2 S466
J2 Internal SCSI Wide (16-bit) connector 68-pin connector J6 External SCSI 2 Wide (16-bit)
J1 Termination Enable Control 3-pin header J3 I2C connector 4-pin header J7 Cache memory SIMM socket 72-pin connector J4 Serial port connector 9-pin connector J8
J10 Short Pins 1-2 3-pin header J11 i960RP configuration 2-pin header J12 i960RP configuration 2-pin header
card are correct. The jumpers and connectors are:
Step 5 Set Jumpers
Cont’d


J4 Serial Port J4 is a 9-pin berg that attaches to a serial cable. The pinout:
Chapter 6 Hardware Installation 59
J3 I2C Interface Connector J3 is a four-pin header that allows the i960JX
Interface Unit. Attach a four-wire cable from J3 to the I2C
J1 Termination Enable J1 is a three-pin header that specifies hardware or
core processor to serve as a master and slave device that
J5 Hard Disk LED J5 is a four-pin connector that attaches to a cable that
connects to the hard disk LED mounted on the computer

Permanently disable all onboard SCSI termination. Short Pins 2-3
resided on the I2C bus when used with the I2C Bus
enclosure. The LED indicates data transfers.
software control of SCSI termination.

2 SCSI Activity Signal
3 SCSI Activity Signal
Bus Interface Unit.

for normal operation (J11 and J12 OPEN). All other modes
J8, J9 J8 and J9 are 3-pin jumpers. The factory setting is Pins 1-2
J11, J12 i960RP Initialization J11 and J12 are 2-pin bergs that specify the
shorted. Pins 1-2 should always be shorted for J8 and J9.
i960RP mode when initially powered up. Mode 3 is used
0 Short Pins 1-2 Short Pins 1-2
2 OPEN Short Pins 1-2
I960RP Initialization Mode J19 Setting J22 Setting
J10 J10 is a 3-pin jumper. Make sure Pins 1-2 of J10 are
1 Short Pins 1-2 OPEN
always shorted. This is the factory setting.
are used for test purposes only.

You must terminate the SCSI bus properly. Set termination
For a disk array, set SCSI bus termination so that removing
Chapter 6 Hardware Installation 61
devices. Disable termination on the SCSI devices. See the
properly to minimize reflections and losses. Termination
should be set at each end of the SCSI cable(s), as shown
configuration. However, you can override this setting by

or adding a SCSI device does not disturb termination. An
easy way to do this is to connect the ADAC Ultra2 S466
external terminator module at the other end of the cable.
below. Termination is always enabled, regardless of the
The connectors between the two ends can connect SCSI
card to one end of the SCSI cable and to connect an
manual for each SCSI device to disable termination.
at both ends of the SCSI cable. The SCSI bus is an
electrical transmission line and must be terminated
setting another state.

termination and termination power are intact when any disk
The SCSI bus is an electrical transmission line and it must
be terminated properly to minimize reflections and losses.
You complete the SCSI bus by setting termination at both
external SCSI terminator module to the end of the cable or
Selecting a Terminator Use standard external SCSI terminators on a SCSI
Terminating Internal SCSI Disk Arrays Set the termination so that SCSI

by attaching a SCSI device that internally terminates the
channel operating at 10 MB/s or higher synchronous data
terminate the other end of the SCSI bus by attaching an
drive is removed from a SCSI channel, as shown below:
You can let ADAC Ultra2 S466 automatically provide
SCSI termination at one end of the SCSI bus. You can
SCSI bus at the end of the SCSI channel.
transfer.
ends.
Cont’d

Terminating External Disk Arrays In most array enclosures, the end of the

Chapter 6 Hardware Installation 63
termination is not disturbed when any drive is removed, as
internal and external drives with ADAC Ultra2 S466. You
still must make sure that the proper SCSI termination and
SCSI cable has an independent SCSI terminator module
that is not part of any SCSI drive. In this way, SCSI
Terminating Internal and External Disk Arrays You can use both
termination power is preserved, as shown below:
shown below:
Cont’d

have a unique SCSI ID regardless of the SCSI channel they
Make sure that no hard disk drives are attached to the same
ROM drives, and other non-disk drive devices must each
performance will be significantly degraded if SCSI hard


Connecting Non-Disk SCSI Devices SCSI Tape drives, scanners, CD-
RAID controller if LVD disk drives are also attached because the
are attached to. The general rule for Unix systems is:
advisable to attach a non-disk device to a ADAC Ultra2 S466
SCSI channel as the non-disk SCSI devices. Drive
Since all non-disk SCSI devices are single ended, it is not
SCSI bus will then operate in single ended mode.
disk drives are attached to this channel.

controller card bus connector to the slot. Press down gently
Chapter 6 Hardware Installation 65
Insert the ADAC Ultra2 S466 card in a PCI slot as shown
Choose a 5 V PCI slot and align the ADAC Ultra2 S466
but firmly to make sure that the card is properly seated in
the slot. The bottom edge of the controller card should be


Screw the bracket to the computer frame.
flush with the slot.
below:


Connect SCSI cables to SCSI devices. ADAC Ultra2 S466
SCSI and J6, the SCSI channel external ultra high-density
devices or single ended 1.5 meters for Ultra SCSI devices. The cable length
internal high-density 68-pin connector for Wide (16-bit)
1 Disable termination on any SCSI device that does not sit at the end of the
4 The cable length should not exceed three meters for Fast SCSI (10 MB/s)
5 The cable length should not exceed six meters for non-Fast SCSI devices.
68-pin connector for Wide (16-bit) SCSI.
Connect SCSI Devices When connecting SCSI devices:
3 Set proper target IDs (TIDs) for all SCSI devices.
2 Configure all SCSI devices to supply TermPWR.
can be up to 12 meters for LVD devices.
SCSI bus.
Cont’d · Step Action

Chapter 6 Hardware Installation 67
Cable Suggestions System throughput problems can occur if SCSI cable use
meters for an 8-drive Ultra SCSI system and no more than 3
device in a specific SCSI channel must have a unique TID
where they are connected. See the documentation for each
from 0 to 6. 16-bit devices can use the TIDs from 0 to 15.
The arbitration priority for a SCSI device depends on its
TID 7 6 5 … 2 1 0 15 14 … 9 8
(no more than 3 meters for Fast SCSI, no more than 1.5
Set target identifiers (TIDs) on the SCSI devices. Each
should have unique SCSI IDs regardless of the channel
in that channel. Non-disk devices (CD-ROM or tapes)
SCSI device to set the TIDs. The ADAC Ultra2 S466
channel. Eight-bit SCSI devices can only use the TIDs
controller automatically occupies TID 7 in the SCSI
Non-disk devices (CD-ROM or tapes) should have unique SCSI
IDs regardless of the channel they are connected to.
meters for a 6-drive Ultra SCSI system),
is not maximized. You should:
shielded or non-shielded), and
characteristics.
TID.
Priority Highest Lowest · inches),

devices because they are limited to IDs 1 through 6. The
SCSI-2 ANSI specification has a limit of eight LUNs per
All logical drives on each SCSI bus are identified to the
host as ID 0. Differentiate the drives with Logical Unit
because LUNs are used to present logical drives. The
ID. The SCSI-3 specification increased the number of
Identifiers (LUNs). ID 0 cannot be used for non-disk
ADAC Ultra2 S466 is limited to eight logical drives
ID LUN Device ID LUN Device
0 0 Disk (A1-X) 1 0 Scanner
0 5 Disk (A6-X) 6 0 Optical
0 1 Disk (A2-X) 2 0 CD
0 2 Disk (A3-X) 3 0 Tape
0 3 Disk (A4-X) 4 0 CD
0 4 Disk (A5-X) 5 0 Tape
LUNs to 16. An example of ID mapping follows.

As Presented to the Operating System
0 6 Disk (A7-X)
0 7 Disk (A8-X)

Chapter 6 Hardware Installation 69
power supplies so that the SCSI devices are powered up at
seconds. The ADAC Ultra2 S466 host adapter (controller)
displayed in the second portion of the BIOS message. The
numbering of the controllers follows the PCI slot scanning
Replace the computer cover and reconnect the AC power
computer is powered up before a SCSI device, the device
The firmware takes several seconds to initialize. During
this time the adapter will scan the SCSI channel. When
cords. Turn power on to the host computer. Set up the
The utility prompt times out after several
number, firmware version, and cache DRAM size are
During boot, the ADAC Ultra2 S466 BIOS message
the same time as or before the host computer. If the
0 Logical Drives found on the Host Adapter 0 Logical Drives handled by BIOS Press to run ADAC Ultra2 S466 BIOS Configuration Utility
ADAC Ultra2 S466 Disk Array Adapter BIOS Version x.xx date
Firmware Initializing... [ Scanning SCSI Device ...(etc.)... ]
Host Adapter-1 Firmware Version x.xx DRAM Size 4 MB
order used by the host motherboard.
ready, the following appears:
might not be recognized.
appears:

ASPI Driver CorelSCSI, Novaback, and PC Tools are not provided with
See the ADAC Ultra2 S466 Configuration Software Guide
channel it resides on. SCSI IDs 1 through 6 are valid,
Drivers Devices Supported Application Software Features
Copy ADACASPI.SYS to your hard disk drive. Add the
Press to run the ADAC BIOS Setup utility.
The ADAC Ultra2 S466 ASPI driver can be used in the
must use a unique SCSI ID regardless of the SCSI
DOS and Windows 95 environments. The DOS ASPI
Tools. VDS
/q Quiet mode. All message except error message are suppressed.
/a Physical drive ccess mode. Direct access to physical drives is
optical drives, etc. CorelSCSI, Novaback, PC
/v Verbose mode. All message are displayed on the screen.
for information about running BIOS Setup.
Parameters The ADACASPI.SYS parameters are:
device=\ADACASPI.SYS /v
following line to CONFIG.SYS:
/h INT 13h support is not provided.
ADAC Ultra2 S466.
driver supports:
ADACASPI.SYS CD-ROM, tape,
drives.
permitted.
Cont’d · Parameter Description

Chapter 6 Hardware Installation 71
CD-ROM drives operating under DOS, Windows 3.x, and
The ADACASPI.SYS ASPI manager must be added to the
device driver. See the instructions on the previous page for
Add the following line to CONFIG.SYS, making sure it is
CD-ROM Driver A device driver is provided with ADAC Ultra2 S466 for
Windows 95. The driver filename is ADACDROM.SYS.
supplied with MS-DOS® and PC-DOS® Version 5.0 or
CONFIG.SYS file before you can install the CD-ROM
ADACDROM.SYS to the root directory of the C: drive.
Add the following to AUTOEXEC.BAT. Make sure it
MSCDEX is the CD-ROM drive extension file that is
later. See your DOS manual for the command line
preceded by the line for ADACASPI.SYS:
adding the ADACASPI.SYS driver. Copy
precedes the SMARTDRV.EXE line.
parameters for MSCDEX.

This chapter discussed hardware installation. Configure the
RAID system via software configuration utilities. See the
ADAC Ultra2 S466 Configuration Software Guide for all
information about ADAC Ultra2 S466 software utilities.
The utility programs for configuring ADAC Ultra2 S466
ADAC BIOS Setup independent of the operating system
Novell NetWare 3.x, 4.x
Power Console Plus Microsoft Windows NT,
Configuration Utility Operating System
are:

process after installation. Make sure the SCSI BIOS on the motherboard
Chapter 7 Troubleshooting 73
slot. It must be installed in the RAID Upgrade
Check the system BIOS configuration for PCI
Initialize the logical drive before installing the
If the drive continues to fail, replace the drive
Check the drives IDs on each channel to make
Check the termination. The device at the end
Set the drives to spin on command. This will
allow ADAC Ultra2 S466 to spin two devices
card is installed in the proper PCI expansion
process after installation. Make sure the ADAC Ultra2 S466 adapter
fails often Check the drive error counts using Power
with another drive with the same capacity.
should install at least 4 MB of memory in
For proper cache memory operation, you
interrupt assignments. Make sure some
These utilities require a color monitor.
sure each device has a different ID.
of the channel must be terminated.
EEPROM. You may need a new EEPROM.
Interrupts are assigned for PCI.
Replace the drive cable.
ADAC Ultra2 S466.
has been disabled.
operating system.
Format the drive.
simultaneously.
Console Plus.
PCI slot..
Some operating systems do not load
in a computer with a ADAC Ultra2
ADAC Ultra2 S466 using the same
ADAConf.exe does not display the
The system hangs during the boot
The system hangs during the boot
One of the hard drive in the array
ADAConf.exe and tried to make a
power supply. There is a problem
Pressing or running
ADAC Ultra2 S466 installed, the
screen display is garbled or does
new configuration. The system
hangs when scanning devices.
spinning the drives all at once.
Multiple drives connected to
At system power-up with the
Pressed . Ran
Cannot flash or update the
Management Menu.
not appear at all.
S466 adapter.
Problem Suggested Solution · Rebuild the drive

is properly terminated using the recommended
Make sure that TERMPWR is being properly
provided to each peripheral device populated
Make sure that each end of the channel chain
terminator type for the peripheral device. The
Make sure (on a channel basis) only two type
Non-hard disk devices can only accommodate
disk devices are supported per ADAC Ultra2
get a drive assignment? To maintain the DOS Path statement integrity.
ADAC Ultra2 S466 card if only one cable is
If using an FPM SIMM, make sure the RAS
controller is properly seated in the PCI slot.
SCSI IDs 1, 2, 3, 4, 5 or 6, regardless of the
channel is automatically terminated at the
channel used. A maximum of six non-hard
of cables are connected at any one time.
Make sure that the ADAC Ultra2 S466
Access Time parameter is 70 ns.
connected to a channel.
S466 adapter.
channel.
What SCSI IDs can a non-hard disk
appears and remains on the screen.
device have and what is maximum
Why does a failed logical array still
Firmware Initializing...
number allowed per adapter?
Problem Suggested Solution

configuration stored on the
connected and are powered
Chapter 7 Troubleshooting 75
ADAC Ultra2 S466 BIOS
Make sure ADAC Ultra2
S466 is properly installed.
Make sure ADAC Ultra2
S466 is properly installed.
Press a key to run ADAC
both the configuration in
problem by selecting one
Manager to find out if any
Message Problem Suggested Solution
Enable the BIOS via the
Configuration Manager.
disk drives. Resolve the
responding. Reconnect,
of the configurations.
sign on. Make sure all physical
physical drives are not
replace, or rebuild any
Configure menu.
drive that is not
Setup utility.
responding.
on.
the configuration stored in
in the ADAC Ultra2 S466
The ADAC Ultra2 S466
Sometimes the BIOS is
booting from the BIOS.
adapter does not match
1 Logical Drive Failed A logical drive failed to
BIOS is disabled.
xxxx Not Responding The BIOS cannot
adapter firmware.
Adapter The BIOS cannot
adapter firmware.
the drives.
Adapter BIOS Disabled.
Host Adapter at Baseport
No ADAC Ultra2 S466
Press any key to run the
Configuration Utility.
Configuration Utility.
mismatch.

connected and are powered
connected and are powered
connected and are powered
Manager to find out if any
Make sure ADAC Ultra2
Make ADAC memory has
Message Problem Suggested Solution
responding. Reconnect,
responding. Reconnect,
S466 memory has been
been properly installed.
Make sure all physical
Manager to find if any
physical drives are not
replace, or rebuild any
in a degraded state. Make sure all physical
physical drives are not
replace, or rebuild any
Make sure the physical
properly installed.
drive that is not
drive that is not
responding.
responding.
on.
on.
on.
Degraded x number of logical drives
Not enough ADAC Ultra2
1 Logical Drive Degraded A logical drive signed on
SCSIO IDs a, b, and c are
signed on in a degraded
Insufficient Memory Not enough memory on
The physical drives with
not responding on SCSI
S466 memory to run
the ADAC adapter to
configuration.
channel x.
BIOS.
state.
run BIOS. Press any key
The following SCSI IDs
are not responding:
Channel x:a.b.c

configuration in NVRAM and
the configuration stored on the
Chapter 7 Troubleshooting 77
Remove the drive or drives
problem by selecting one of
Message Problem Suggested Solution
Press a key to run ADAC
that should not be used.
Configuration Manager.
disk drives. Resolve the
Reconfigure the array.
to examine both the
the configurations.
Configure menu.
feature did not find the physical
and c. ADAC cannot determine
The configuration stored in the
ADAC NVRAM does not match
ID. No slot is available to map
feature found the same data on
two or more physical drive on
channel x with SCSI IDs a, b,
the drive that has the duplicate
the configuration stored on the
disk with the displayed SCSI
The physical disk roaming
cannot resolve the physical
The physical drive roaming
the physical drive. ADAC
drives into the current
configuration.
information.
drives.
same data y, z

error code=[0xab] Correct the condition that caused the failure. The failure
CONFIG.SYS or this driver is used with a BIOS that is
0x80 Timed out waiting for interrupt to be posted
0x81 Timed out waiting for Response command.
0x85 No adapters found or no PCI BIOS support.
during scanning. A SCSI device that is not a hard disk
drive, such as a tape drive or CD-ROM drive, must be
unique for each adapter and cannot be SCSI ID 0. The
earlier than v1.10, or no logical drives are configured.
has NOT been loaded. The ASPI manager is not loaded. One of the failure
attached to this SCSI channel. The SCSI ID must be
located The driver did not find any non-hard drive devices
0x82 Invalid command completion count.
0x83 Invalid completion status received.
0x90 Unknown Setup completion error
supported SCSI IDs are 1, 2, 3, 4, 5, and 6.
0x84 Invalid command ID received.
codes listed below is displayed next.
The /h option is appended to driver in
0x40 No ADAC adapters found
codes are:
Gateway Inc. ASPI Manager
No non-disk devices were
*INACTIVE* for logical drives
Message Corrective Action · Controller setup FAILED

Virtual Sizing The Virtual Sizing option enables RAID expansion. Virtual
Chapter 7 Troubleshooting 79
under DOS At this time, copied CDs are not accessible from DOS even
Physical Drive Errors To display the ADAC Configuration Manager Media Error
occurred while actually transferring data. An Other Error is
Multiple LUNs ADAC Ultra2 S466 supports one LUN per each target ID.
Power Requirements The maximum ADAC Ultra2 S466 power requirements are
DOS ASPI ADACASPI.SYS, the DOS ASPI manager, uses 6 KB of
device failure, poor cabling, bad termination, signal loss,
drive or add a physical drive to an existing logical drive.
BSD Unix We do not provide a driver for BSDI Unix. ADAC Ultra2
after loading ADACASPI.SYS and ADACDROM.SYS.
physical drive under the Physical Drive menu, selected
Run ADAC Configuration Manager by pressing
to enable Virtual Sizing. Select the Objects menu,
then select the Logical Drive menu. Select View/Update
from the Objects menu. A Media Error is an error that
an error that occurs at the hardware level because of a
Sizing must be enabled to increase the size of a logical
and Other Error options, press after selecting a
Parameters. Set Virtual Sizing to Enabled.
No multiple LUN devices are supported.
S466 does not support BSDI Unix.
system memory once it is loaded.
15 watts at 5V and 3 Amps.
etc.
Topic Information · CD-ROM drives

The characteristic impedance of the cable should be 90 +/-
6 ohms for the /REQ and /ACK signals and 90 +/- 10 ohms for all other signals.
The stub length(the distance from the controller’s external
The spacing of devices on the mainline SCSI bus should be
All signal lines shall be terminated once at both ends of the
The maximum signal path length between terminators is 3
meters when using up to 4 maximum capacitance (25 pF)
connector to the mainline SCSI bus) shall not exceed.1m
devices and 1.5 meters when using more than 4 devices.
terminators, with the end devices located as close as
SCSI devices should be uniformly spaced between
Requirements The ANSI specification dictates the following:
bus powered by the TERMPWR line.
at least three times the stub length.
possible to the terminators.
(approximately 4 inches).
Topic Information · SCSI Bus

Chapter 7 Troubleshooting 81
devices on the ADAC Ultra2 S466 will not be recognized
supported SCSI host adapters without making the devices
until after the initial reboot. The Microsoft documented
Setup could not determine the type of one or more
list. In some cases, Windows NT Setup repeatedly
Installation When Windows NT is installed via a bootable CD, the
press to prevents Windows NT Setup from
performing disk controller detection. This allows
you to install the driver from the Drivers disk you
mass storage devices installed in your system, or
you have chosen to manually specify an adapter,
5 Insert the Drivers Disk you made when prompted
to do so and select ADAC Ultra2 S466 from this
Repeat this step for each host adapter not already
press S to display a list of supported SCSI host
To install drivers when Setup recognizes one of the
Setup is inspecting your computer’s hardware
prompts to swap disks. Windows NT will now
recognize any devices attached to this adapter.
created. All SCSI adapters must be installed
4 Select Other from the bottom of the list.
2 When Windows NT Setup displays
recognized by Windows NT Setup.
SETUP.TXT is on diskette 2 or the CD
1 Restart Windows NT Setup.
workaround is in SETUP.TXT:
attached to it available for use:
configuration...,
manually.
adapters.
Topic Information · Windows NT



differebtial primary bus (P-CABLE) as specified in SCSI-3
Appendix A SCSI Cables and Connectors 83
The SCSI channel on the ADAC Ultra2 S466 Controller
ADAC Ultra2 S466 to wide SCSI devices. The following
connector pinouts are provided for both single-ended and
connectors to internal non-wide (Type 2) connectors,
ADAC Ultra2 S466 provides several different types of
Parallel Interface X3T9.2, Project 885-D, revision 12b,
internal non-wide SCSI connectors (Type 30), and
has a 68-pin high density 0.050 inch pitch unshielded
This connector provides all signals needed to connect
The cable assemblies that interface with the 68-pin
internal non-wide SCSI connectors.
SCSI connectors. The connectors are:
and external wide SCSI devices,
date July 2, 1993.
connector is:
connector.
Cont’d · wide SCSI devices,


Cable Assembly for Internal Wide SCSI Devices The cable assembly for
connecting internal wide SCSI devices is shown below:
Cont’d

connecting internal wide and external wide SCSI devices is
Appendix A SCSI Cables and Connectors 85
Connecting Internal and External Wide Devices The cable assembly for
A
B
B
kit 749087-1, 749087-2, or 750644-1
Cable: Flat Ribbon or Twisted-Pair Flat Cable
Connector A: 68 position panel mount receptacle

68-Pin High Density Connectors, Continued
with 4-40 holes (female)
Connector B: 68 position plug (male)
AMP - 786096-7
AMP - 786090-7
from AMP
shown below:
Cont’d


assembly for converting internal wide SCSI connectors to
Converting Internal Wide to Internal Non-Wide (Type 2) The cable
internal non-wide SCSI connectors is shown below:

Cont’d

Appendix A SCSI Cables and Connectors 87
Converting Internal Wide to Internal Non-Wide (Type 30) The cable
assembly for connecting internal wide SCSI devices to
A
internal non-wide SCSI devices is shown below:

Laminated Discrete Wire Cable
25 pair 0.050 centerline 28 AWG
Connector B:50 position plug (male)
AMP - 749925-3
Cont’d

Converting from Internal Wide to Internal Non-Wide (Type 3) The cable

internal non-wide (Type 3) SCSI devices is shown below:
Manufacturer Connector Part Number Back Shell Part Number
assembly for connecting internal wide SCSI devices to
AMP 749111-4 749193-1 Fujitsu FCN-237R050-G/F FCN-230C050-D/E
SCSI Cable Vendors
Honda PCS-XE50MA PCS-E50LA · Manufacturer Telephone Number


Appendix A SCSI Cables and Connectors 89
Ground 33 65 66 67 -DB(10)
Ground 34 67 68 68 -DB(11)
Ground 28 55 56 62 -C/D
Ground 29 57 58 63 -REQ
Ground 31 61 62 65 -DB(8)
Ground 32 63 64 66 -DB(9)
Ground 30 59 60 64 -I/O
Cont’d

when using 0.025 inch centerline flat ribbon cable with
High-Density Single Ended Connector The following applies to the high-
a high-density connector (AMPLIMITE.050 Series
(10), -DB (11), -DB(12), -DB (13), -DB (14), -DB
15), and -DB (P1). • All other signals should be connected as defined.
density SCSI connector table on the previous page:
Lines labeled RESERVED should be connected to Ground
in the bus terminator assemblies or in the end devices on the
RESERVED lines should be open in the other SCSI
devices, but can be connected to Ground.
SCSI cable.
connectors).
active low.


Appendix A SCSI Cables and Connectors 91
+DB(8) 31 61 62 65 -DB(8)
+DB(9) 32 63 64 66 -DB(9)
+DB(10) 33 65 66 67 -DB(10)
+DB(11) 34 67 68 68 -DB(11)
+I/O 30 59 60 64 -I/O
68-Pin Connector Pinout for LVD SCSI
when using flat-ribbon cable.



Appendix B Audible Warnings 93
The ADAC Ultra2 S466 RAID controller has an onboard
offline. One or more drives in a RAID
Two or more drives in a RAID
While you were away from the
system, a disk drive in a RAID
1, 3, or 5 configuration failed. One second on
1, 3, or 5 configuration failed and was rebuilt.
One drive in a RAID 3 or 5
The audible warning were not enabled at the time this manual
0 configuration failed.
tone generator that indicates events and errors.
Tone Pattern Meaning Examples
configuration failed.
went to press.
A logical drive is
A logical drive is
been completed.
mode.










Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The system hangs during the boot process after installation. | Make sure the SCSI BIOS on the motherboard has been disabled. | p.87 | |
| The system hangs during the boot process after installation. | Make sure the ADAC Ultra2 S466 adapter card is installed in the proper PCI expansion slot. It must be installed in the RAID Upgrade PCI slot.. | p.87 | |
| Some operating systems do not load in a computer with a ADAC Ultra2 S466 adapter. | Check the system BIOS configuration for PCI interrupt assignments. Make sure some Interrupts are assigned for PCI. Initialize the logical drive before installing the operating system. | p.87 | |
| The ADAC Ultra2 S466 BIOS is disabled. Sometimes the BIOS is disabled to prevent booting from the BIOS. | Enable the BIOS via the ADAC Ultra2 S466 BIOS Setup utility. | p.89 | |
| The BIOS cannot communicate with the adapter firmware. | Make sure ADAC Ultra2 S466 is properly installed. | p.89 | |
| x number of logical drives signed on in a degraded state. | Make sure all physical drives are properly connected and are powered on. Run ADAC Configuration Manager to find if any physical drives are not responding. Reconnect, replace, or rebuild any drive that is not responding. | p.90 | |
| The physical disk roaming feature did not find the physical disk with the displayed SCSI ID. No slot is available to map the physical drive. ADAC cannot resolve the physical drives into the current configuration. | Reconfigure the array. | p.91 |
Owners and our team usually reply within a day — and your question helps the next person too.