EN
Furuno logo
Official user manual

Furuno FleetBroadband 500 (FELCOM 500)

66 pages·6.5 MB·Network Router·PDF·ENDEFRITNLJA
Furuno FleetBroadband 500 (FELCOM 500)
Table of Contents 29 sections SAFETY INSTRUCTIONS · EQUIPMENT LISTS · 1. HOW TO INSTALL THE UNIT · 1.1 Antenna Unit · … ShowHide
Page 2 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — H : FEB. 18, 2011 Pub. No. IME-56660-H
Page 2 · click to enlarge
Page 2
Furuno FleetBroadband 500 (FELCOM 500) diagram (page 2)
Fig. 1

The paper used in this manual is elemental chlorine free.

Furuno FleetBroadband 500 (FELCOM 500) diagram (page 2)
Fig. 2

9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN

Telephone+81-(0)798-65-2111
Fax+81-(0)798-65-4200

A : AUG 2009 . Printed in Japan All rights reserved.

H : FEB. 18, 2011 Pub. No. IME-56660-H

*00017097917* *00017097917* (YOSH ) FELCOM500/250

*00017097917* *00017097917* * 0 0 0 1 7 0 9 7 9 1 7 *

・FURUNO Authorized Distributor/Dealer

Page 3 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — SAFETY INSTRUCTIONS
Page 3 · click to enlarge
Page 3

SAFETY INSTRUCTIONS

Read these safety instructions before you operate the equipment. Indicates a condition that can cause death or serious injury if WARNING not avoided. Indicates a condition that can cause minor or moderate injury if CAUTION not avoided. Warning, Caution Prohibitive Action Mandatory Action WARNING WARNING Do not open the equipment unless Ground the equipment to prevent totally familiar with electrical circuits electrical shock and mutual and service manual. interference. Only qualified personnel should work Confirm that the power supply voltage inside the equipment. is compatible with the voltage rating of the equipment. Do not approach the radome closer than 1.4 m (FELCOM 500) or 0.7 m Connection to the wrong power supply (FELCOM 250) when it is transmitting. can cause fire or damage the equipment. The radome emits radio waves which Keep the following compass safe can be harmful to the human body, distances to prevent interference to particularly the eyes. a magnetic compass. RF power dendity FELCOM500FELCOM250 on antenna aperture distance distance Standard Steering Unit 100W/m2 - - compass compass FELCOM 500 25W/m 2 0.5 m 0.4 m 0.75m 0.40 m Antenna Unit 10W/m 2 1.4 m 0.7 m FELCOM 250 0.70m 0.40 m Antenna Unit Turn off the power at the mains Communication Unit 0.40 m 0.30 m switchboard before beginning the installation. Post a sign near the IP Handset 0.70 m 0.45 m switch to indicate it should not be Facsimile 1.30 m 0.80 m turned on while the equipment is being installed. Telephone 0.50 m 0.40 m Incoming Indicator 0.45 m 0.30 m Fire, electrical shock or serious injury can result if thepower is left on or is AC-DC Power Supply 0.90 m 0.60 m applied while the eqiuipment is being installed. WARNING Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. Do not approach the radome closer than 1.4 m (FELCOM 500) or 0.7 m (FELCOM 250) when it is transmitting. The radome emits radio waves which can be harmful to the human body, particularly the eyes. RF power dendity on antenna aperture 100W/m2FELCOM500 distance -FELCOM250 distance - 25W/m 20.5 m0.4 m 10W/m 21.4 m0.7 m Turn off the power at the mains switchboard before beginning the installation. Post a sign near the switch to indicate it should not be turned on while the equipment is being installed. Fire, electrical shock or serious injury can result if thepower is left on or is applied while the eqiuipment is being installed.
Unit FELCOM 500 Antenna UnitStandard compass 0.75mSteering compass 0.40 m FELCOM 250 Antenna Unit0.70m0.40 m Communication Unit0.40 m0.30 m IP Handset0.70 m0.45 m Facsimile1.30 m0.80 m Telephone0.50 m0.40 m Incoming Indicator0.45 m0.30 m AC-DC Power Supply0.90 m0.60 m
Page 4 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — RS-232C
Page 4 · click to enlarge
Page 4

SYSTEM CONFIGURATION

FB-1500 (FELCOM 500)

FB-1250 (FELCOM 250)

LAN(4)

FB-2000

TEL(4)

12-24 VDC

PC

AC-DC Power supply PR-240

100-115/ 200-230 VAC

Analog telephone Analog telephone

NMEA

Solid lineBasic configuration

RS-232C

Antenna unitTo be installed in an exposed area Communication unit, IP handset, etc.To be installed in a protecded area
Show 12 more labels / short text on this page
Antenna unit · IP Handset FB-8000 · Communication unit · Incoming indicator FB-3000 · Network Equipment · G3 facsimile · Analog telephone · Navigation equipment · Normal Close · External alarm · PC or Router · Environmental Category
Page 5 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Optional Supply
Page 5 · click to enlarge
Page 5

EQUIPMENT LISTS

Standard Supply

NameTypeCode No.QtyRemarks Antenna unitFB-1500-1For FELCOM 500 FB-1250-For FELCOM 250 Communication unitFB-2000-1 IP handsetFB-8000-1 Installation materials*CP16-04100000-015-746130 m antenna cable CP16-04110000-015-74750 m antenna cable CP16-04120000-015-86540 m antenna cable CP16-04401001-093-4601For FB-1500 CP16-04501001-093-4801For FB-1250 CP16-03810000-015-7591For FB-2000 CP16-03901001-067-3501For FB-8000 AccessoriesFP16-02200000-015-7621CD-ROM for FB-2000 Spare partsSP16-01901001-067-3201Fuses for FB-2000

*: See lists at the back of this manual.

Optional Supply

NameTypeCode No.Remarks Incoming indicatorFB-3000000-015-763w/CP16-04001 TelephoneFC755D1000-043-369w/CP16-00511, 00512 FacsimileFAX-2820-w/CP16-03500, 220VAC TransformerOP16-25004-446-850Transformer TSU-N05E +cable for FAX-2820 Drum unitDR-20J000-170-982-10For FAX-2820 Toner cartridgeTN-25J001-111-660-10For FAX-2820 AC-DC power supplyPR-240- IP handsetFB-8000- Coaxial cable12D-SFA-CV000-136-423-11100 m for antenna cable Installation materialsCP16-04121001-067-300Connector N-SP-12DSFA-CF for cable 12D-SFA-CV CP16-04131001-067-310Connector N-P-18U-CF (2 pcs) for RG-18
Page 6 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — EQUIPMENT LISTS
Page 6 · click to enlarge
Page 6

EQUIPMENT LISTS

NameTypeCode No.Remarks ConnectorCP03-28901008-542-460Modular connector MPS588-C2 pcs for LAN cable LAN cableMOD-Z072-020+000-167-175-102 m, modular plug for both ends MOD-Z072-050+000-167-176-105 m, modular plug for both ends MOD-Z072-100+000-167-177-1010 m, modular plug for both ends FR-FTPC-CY *10m*000-147-472-1010 m with armor, no plug FR-FTPC-CY *20m*000-147-473-1020 m with armor, no plug FR-FTPC-CY *30m*000-147-474-1030 m with armor, no plug FR-FTPC-CY *50m*000-153-326-1050 m with armor, no plug FR-FTPC-CY *100m*000-153-327-10100 m with armor, no plug Modular jack setOP16-13000-043-228MJ-2S, 3 m cord, lug Modular jack boxOP16-8000-043-272MJ-2S, lug Joint boxTL-CAT-012000-167-140-10Fro LAN cable extension Cable assy.81-521-1204-010000-127-108-115 m cable w/ D-sub 9 pin connector at both ends Incoming IndicatorKK-893-3977000-148-478For analog TEL. Modular jack boxOP16-10000-043-278Box type OP16-11000-043-279Flush mount type Pole mount kitOP16-52000-017-061For FELCOM 250 antenna unit Kit for RF interferenceOP16-50000-016-316For FELCOM 500 Radiation stickerOP16-53001-115-470-10For FELCOM 500

This product includes software to be licensed under the GNU General Public License (GPL), GNU Lesser General Public License (LGPL), BSD, Apache, MIT and others.The program(s) is/are free software(s), and you can copy it and/or redistribute it and/or modify it under the terms of the GPL or LGPL as published by the Free Software Foundation. Please access to the following URL if you need source codes. https://www.furuno.co.jp/contact/cnt_oss.html

This product uses the software module that was developed by the Independent JPEG Group.

France Telecom - TDF - Groupe des Ecoles des Telecommunications Turbo codes patents license.

Page 7 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Select a location low in vibration
Page 7 · click to enlarge
Page 7

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1 Antenna Unit

General

Interfering objects (especially metal objects like masts) near the antenna can, in the worst case, prevent reception or transmission. Further, RF radiation from the antenna will affect the human body. Keep these and the following guidelines in mind when selecting a mounting location for the antenna unit.

Secure unobstructed path in all directions

The best mounting location secures an unobstructed path between the antenna unit and the sat- ellites, from horizontal to zenith. In other words, whatever the direction the antenna unit is pointing there are no interfering objects within the main beam (22° for FELCOM 500, 40° for FELCOM 250). While this might be feasible on some vessels, on others it is impossible due to space con- siderations. The antenna unit should be located at least three meters away from masts having a diameter less than 15 centimeters.

Select a location low in vibration

The maximum permissible vibration amplitude in three axis direction should be as shown in the table below. Consult with the shipyard to determine the mounting location which meets the re- quirements shown in the table.

Freq. RangeMax. Amplitude 4 to 10 Hz2.54 mm (max. 9.8 m/s2) 10 to 15 Hz0.76 mm (max. 6.86 m/s2) 15 to 25 Hz0.40 mm (max. 9.8 m/s2) 25 to 33 Hz0.23 mm (max. 9.8 m/s2)
Page 8 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Locate away from passengers and crew
Page 8 · click to enlarge
Page 8

Locate away from passengers and crew

Radio waves can be harmful to the human body. Because safe distances change by country and ship construction, there is no standard formula to calculate safe distance. However, below are general guidelines.

  • FELCOM 500: Personnel should not approach an area in which the radiation level is higher than 10 W/m2, i.e., within 1.40 m from the radome surface.
Furuno FleetBroadband 500 (FELCOM 500) — Locate away from passengers and crew diagram (page 8)
Fig. 3 · Locate away from passengers and crew

Do not approatch within 1.40 m of the antenna radome when it is transmiting. Microwave radiation can be harmful to the human body, particularly the eyes.

Construct a protective fence around the antenna unit so that personnel can not approach the antenna unit within 1.40 m. Also, to alert personnel not to approach the antenna unit, attach the caution labels (supplied as installation materials) to any bulkhead which is at the position of 1.40 m from the antenna unit.

Furuno FleetBroadband 500 (FELCOM 500) — Locate away from passengers and crew diagram (page 8)
Fig. 4 · Locate away from passengers and crew
Page 9 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Minimum distance from other antennas
Page 9 · click to enlarge
Page 9
  • FELCOM 250: Personnel should not approach an area in which the radiation level is higher than 10 W/m2, i.e., within 0.70 m from the radome surface.

MICROWAVE RADIATION ! NO ADMITTANCE WITHIN 0.7 m

0.7 m

Construct a protective fence around the antenna unit so that personnel can not approach the antenna unit within 0.70 m. Also, to alert personnel not to approach the antenna unit, attach the radiation warning sticker (supplied as installation materials) to any bulkhead which is at the po- sition of 0.70 m from the antenna unit.

Minimum distance from other antennas

MF/HF antennas, communication/navigation antennas:

The antenna unit should be at least five meters from a MF/HF antenna. The VHF, satellite navi- gation antenna and other communication antennas should be at least four meters away.

Radar:

The antenna unit should be at least 5 meters away to protect the low-noise amplifier in the FEL- COM 500/FELCOM 250 antenna unit. If this distance cannot be secured be sure the antenna unit is not within the radar beam. However, never install the antenna unit within 3 m of a radar antenna.

More than 5 m

If installed within 5 m of radar antenna, the antenna unit must not be within the radar beam. Never install the antenna unit within 3 m.

Distance from radar antenna

Page 10 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Mast strength
Page 10 · click to enlarge
Page 10

Compass safe distance

Locating the antenna unit too close to a compass can affect the compass performance. Keep the compass safe distance to prevent interference to the magnetic compass. See page i.

Other mounting guidelines

Other important mounting guidelines are

  • Locate the antenna unit away from exhaust stacks (foreign material on the radome can interfere with reception and transmission).
  • Keep the unit away from heat sources.
  • Locate the unit away from places where fuels and chemical solvents are stored.
  • Keep in mind the length of the cable from the communication unit is maximum 100 meters (when coaxial cable 12D-SFA-CV is used).

Guardrail, platform

To facilitate servicing, construct a mast of about one meter (40") in height. (See page 5.) The para- graphs which follow provide guidelines for selection and construction of the mast.

Fit the mast with a guardrail and platform (or steps), for serviceman's safety. (In most installations the serviceman stands on the platform while checking the radome. Thus this distance should be secured for ease of servicing.) The height of the guardrail should be as tall as possible to ensure safety.

Mast strength

The mast material must be sufficiently strong to meet the demands of the marine environment. It should satisfy the following requirements.

  • It must be able to support radome mass plus at least 2.5 cm (1") of ice and snow. Special consideration should be given if the unit is operated in areas of heavy snow or freezing temperature.
  • The mast bending moment must be able to withstand expected maximum pitching, rolling and wind pressure.
  • To prevent resonance at low frequencies (approximately 5 Hz), four stays can be fixed between the mast and the mounting base.
(Above figureFELCOM 500)
ItemFELCOM 500FELCOM 250 Antenna unit mass21 kg (46 lb) ± 10%6.5 kg ± 10% Platform, guardrail mass Expected ice and snow Maximum wind pressure (at wind speed 56 m/s)280 N36.3 N

Wind Pressure

Page 11 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Antenna mast and mounting base
Page 11 · click to enlarge
Page 11

Antenna mast and mounting base

To get the best performance from the antenna electronics and mechanics, the antenna must be installed properly on a specially designed mast with suitable flange and rubber gasket. Below are guidelines for installation of the mounting mast and mounting base.

  • The mounting base should be parallel to the ship's waterline (tolerance: ±3°).
  • Weld a ground bolt of stainless steel to the mast (figure below). Connect the ground wire from the antenna unit to the ground bolt.
FELCOM 500FELCOM 250 HOLE DIA 12 mm (0.47") (14.17") (10") mm mm 254 360 254 mm (10") 360 mm (14.17") [Mounting base] Thickness: Minimum 20 mm (0.79") (4") Weld a ground bolt mm Approx. M10x40 (same direction of the 100 cable gland of the antenna unit) φ139.8 (φ5.50") [Antenna mast: Example]1 200 mm (7.87") 1 0 m m (4 .3 3 ") (7.87") mm 200 6×φ8 φ60 (φ2.36") Fixing Hole Cable Entry and Drain [Mounting base] Thickness: Minimum 10 mm (0.39") (4") Weld a ground bolt M6x40 mm Approx. Weld an elbow pipe for the cable entrance. 100 The inner diameter should be larger than the outer diameter of φ76.3 the cable. (φ3.00") Don't seal with putty. Make a drain hole at the base of the pole. [Antenna pole: Example]
Furuno FleetBroadband 500 (FELCOM 500) — Antenna mast and mounting base diagram (page 11)
Fig. 5 · Antenna mast and mounting base
Page 12 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Procedure
Page 12 · click to enlarge
Page 12

FELCOM 500: How to install the antenna unit

Carefully unpack the radome and check for damage.

Antenna unit installation materials

ItemQuantityRemarks Silicone sealant150 g Rubber mat1 Radiation warning sticker1 Hex bolt4M10x60 Hex nut8M10 Spring washer8M10 Flat washer8M10 Seal washer4

Procedure

1. Loosen four lifting lugs and turn them to outside at the bottom of the radome as shown in the figure on the next page. Then fasten four screws for lifting lugs firmly.
2. Run lifting rope with shackles through lifting lugs.
3. Cover the part of the radome which contacts the lifting rope with protective material (rubber mat, etc.), to prevent damage to the radome when hoisting it to the mounting location.
4. Lift the antenna unit to the mounting location.
Page 13 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 1. HOW TO INSTALL THE UNIT
Page 13 · click to enlarge
Page 13
5. Lay the rubber mat on the mounting base and put the antenna unit on the rubber mat, keeping in mind cable gland direction (standard direction is stern).

Turn four lifting lugs to outside.

6. Fix the antenna unit with four sets of hexagonal bolts and nuts as shown on the next page. Note: Tighten first nut with torque 36.5 Nm, then tighten second nut with the same torque.
7. Connect the ground wire to the ground bolt.
8. Coat all bolts and nuts with silicone sealant to prevent electrolytic corrosion.
Show 7 more labels / short text on this page
Lifting lug · Lifting rope · Radome · Protective Material · Rope · Shackle · Lifting lug
Page 14 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Item Quantity Remarks
Page 14 · click to enlarge
Page 14
9. Restore the lifting lugs to their original positions.

Rubber mat Ground stud

FELCOM 250: How to install the antenna unit

Carefully unpack the radome and check for damage. Run the antenna cable before installation of the antenna unit.

Antenna unit installation materials

Item Quantity Remarks

Silicone sealant 1 50 g

Rubber mat 1 This mat may be pre-attached to the antenna unit depending on the date of production.

Radiation warning sticker (S) 2

Radiation warning sticker (L) 1

Hex nut 12 M6

Spring washer 6 M6

Flat washer 6 M6

Ground wire 1 200 mm, W/6 mm crimp-on lug for both ends

Show 8 more labels / short text on this page
Nut · Silicone sealant · Seal washer · Spring washer · Flat washer · Bolt · Silicone sealant · Silicone sealant
Page 15 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Procedure
Page 15 · click to enlarge
Page 15

Procedure

1. Attach the rubber mat on the bottom of the antenna unit if the mat is supplied as the installation material.
2. Connect the antenna cable to the coaxial plug on the bottom of the antenna unit.
3. Wrap the self-adhesive tape all around the coaxial connector for waterproofing and wrap the vinyl tape on the self-adhesive tape.

Wrap self-adhesive tape all around the coaxial connector and wrap vinyl tape on it for waterproofing.

4. Put the antenna unit on the mounting base. The antenna unit is free of direction. However, preferably install the antenna unit, so the FURUNO logos face the port/ starboard side.
5. Fasten the ground wire (supplied) to the antenna bolt near the ground stud on the antenna mast and secure with hexagonal nut, spring washer and flat washer.
6. Secure other antenna bolts with a set of hexagonal nuts, spring washers and flat washers as shown below on the next page. Note: To fix the antenna bolt, tighten first nut with torque 7.65 Nm and then tighten the second nut with the same torque.
7. Connect the ground wire to the ground stud on the antenna mast.
8. Attach the radiation warning sticker (small) to the bow and stern sides of the antenna radome. If these locations are not suitable, attach the radiation warning stciker (big) to the ship’s body near the antenna radome.

Rubber mat · Coaxial cable · Antenna unit bottom

Page 16 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 1. HOW TO INSTALL THE UNIT
Page 16 · click to enlarge
Page 16
9. Coat all bolts and nuts with silicone sealant to prevent electrolytic corrosion as shown below.
Show 6 more labels / short text on this page
Flat washer · Spring washer · Silicone sealant · Nut · Antenna fixing bolt · Silicone sealant
Page 17 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Name Type Code no. Qty
Page 17 · click to enlarge
Page 17

How to mount the FELCOM 250 antenna unit with optional pole mount kit

Pole mount kitType OP16-52, Code number 000-017-061

Name Type Code no. Qty

Mounting pole SP-SAC-1031 000-173-963-10 1

Fixing plate SP-SAC-1032 000-173-964-10 1

1. Ask the shipyard to prepare and mount an antenna mast (diameter φ 89: 80A).
2. Attach the fixing plate SP-SAC-1032 to the antenna mast by hanging the lip of the fixing plate on the top of the antenna mast.
3. Insert the mounting pole SP-SAC-1031 through the U-bolts of the fixing plate and fasten the U-bolts.
4. Put the FELCOM 250 antenna unit on the mounting pole and fix it with nuts (see previous page).

Antenna unit (Shipyead suplly)

Show 7 more labels / short text on this page
φ180 · Lip · U-bolt · φ89 (80A) · Mounting pole · φ76 (65A) · Fixing plate
Page 18 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — I POWER 1 TX 2 3 4
Page 18 · click to enlarge
Page 18

1.2 Communication Unit

Select a location for the communication unit (CU) by following the information shown below.

  • The unit is not waterproof. Keep the unit away from water splash.
  • Keep the unit away from direct sunlight.
  • The temperature and humidity must meet the requirements shown in the equipment specifications.
  • Set the unit away from the exhaust pipes and vents.
  • The installation location must have enough cool air.
  • Install the unit where shock and vibration meet the requirements shown in the equipment specifications.
  • Keep the unit away from the equipment that creates an electromagnetic field, for example, motor and generator.
  • For maintenance and checking, leave enough space at the sides and rear of the unit. Refer to the outline drawing and provide some additional length in cables.
  • Follow the recommended compass safe distances shown on page i to prevent the interference to a magnetic compass.

How to install the CU

Follow the procedure shown below to install the CU on a desktop. See the outline drawing on page D-3 for details.

1. Place the template (supplied) of the CU on the installation site.
2. Mark the points for four pilot holes and makes the pilot holes for 5x50 self-tapping screws.
3. Put the unit on the installation site and fix it with four 5x50 self-tapping screws (supplied).

4-φ6 mm (0.24") Fixing holes

52.5 mm (2.07") 160±0.5 mm (6.30")

350±0.5 mm (13.78")

375 mm (14.76")

I POWER 1 TX 2 3 4

READY

POWER OFF BEFORE INSERTING

OR REMOVING SIM

SIM CARD INSIDE

POWER

Show 4 more labels / short text on this page
STATUS Inmarsat FleetBroadband · ― · ○ · ○
Page 19 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — VIEW A
Page 19 · click to enlarge
Page 19

1.3 IP Handset

The IP handset functions as a display and it may also be used for normal voice communication. The units (max 26 units) may be installed anywhere onboard the vessel. The IP handset is pro- vided with a cradle. Fix the cradle to the bulkhead or installation panel. The cradle has two cable entries for convenience; bottom and rear.

1. To use the rear cable entry, make a hole of 18 mm (0.71") diameter in the installation site, Refer to the outline drawing.
2. Remove four screws from the cradle to separate the plastic case from the metal plate.
3. Fix the metal plate to the mounting site with four self-tapping screws.
4. Connect the LAN cable from the CU to the inner RJ45 port in the cradle.
5. If the bottom cable entry is used, run the LAN cable as shown in the figure below and fix it with a cable-tie.
6. Reattach the plastic cover.
7. Connect the cable from the handset to the outer RJ-45 port of the cradle.

4-φ4 Fixing holes

59 (2.32")

52 (2.05”)

Cable entry from the CU

Cable entry (rear entry)

204 (8.03")

35±0.5 (1.38")

4-φ4 Fixing holes

26 (1.02")

26 (1.02")

A

φ18 (0.71")

Cable entry (rear )

CRADLE

Fix with a cable-tie

RJ45

Cable from the CU

Cable from the handset

VIEW A

Show 5 more labels / short text on this page
Cable entry (bottom) · Metal plate · (Rear) · Metal plate · (Bottom)
Page 20 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — How to install by the flush mount
Page 20 · click to enlarge
Page 20

1.4 Incoming Indicator (option)

Select a location for the incoming indicator by following the information shown below.

  • Keep the unit away from water splash.
  • Keep the unit away from direct sunlight.
  • Set the unit away from the exhaust pipes and vents.
  • Follow the recommended compass safe distances shown on page i to prevent the interference to a magnetic compass.

How to install on the bulkhead or bridge panel

1. Remove four screws from the unit to remove the lid.
2. Fix the case with four 4x16 self-tapping screws (supplied).
3. Reattach the lid with four screws.
4. Connect the cable from the CU.
5. Attach the cable fixture (supplied) with two screws.
6. Fasten the cable to the cable fixture with the cable tie (supplied).

45 (1.77") 4-φ5 (0.20")

FIXING HOLES

60±0.5 (2.36")

INCOMING INDICATOR

15 (0.59") 90±0.5 (3.54")

120 (4.72")

ACK

VOLUME

Remove 4 screws to remove the lid.

Cable from the CU

How to install by the flush mount

1. Prepare a cutout in the installation location and make four pilot holes. Refer to the outline drawings.
2. Set the flush mount plate (supplied) to the cutout and fix it with four 4x16 self-tapping screws (supplied).
3. Remove four screws from the unit to remove the lid.
Show 4 more labels / short text on this page
Case · Inmarsat FleetBroadband · Cable fixture · Cable tie
Page 21 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — INCOMING INDICATOR
Page 21 · click to enlarge
Page 21
4. Fix the case with four M4x8 screws (supplied) to the flush mount plate.
5. Pass the cable from the CU through the bottom of the case.
6. Connect the cable to the port on the lid.
7. Attach the cable fixture (supplied) with two screws.
8. Fasten the cable to the cable fixture with the cable tie (supplied).
9. Reattach the lid to the case with four screws.

127±1 (5.00")

132±0.5 (5.20")

99±1 (3.90")

4-PILOT HOLES

111±0.5 (4.37")

CUTOUT DIMENSIONS

123 (4.84")

4-φ5 (0.20") 36.5 (1.44")

111±0.5 (4.37")

FIXING HOLES

132±0.5 (5.20")

144 (5.67")

INCOMING INDICATOR

ACK

VOLUME

Inmarsat FleetBroadband

Page 22 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — FRONT
Page 22 · click to enlarge
Page 22

1.5 Facsimile FAX-2820 (Option)

φ6 Fixing hole Four places

FRONT

1. Lay the facsimile on the top of the mounting plate.
2. Align right side and rear with the projection on the mounting plate.
3. Fasten fixing plates (left, right) to the facsimile with six M4x15 pan head screws.
Show 6 more labels / short text on this page
Mounting plate · Align · Fixing plate (right) · Fixing plate (left) · M4x15 Six places · Facsimile
Page 23 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Mounting location
Page 23 · click to enlarge
Page 23
4. Attach the compass safe distance label at the location shown below.

Compass safe distance label

How to change modem settings

1. Press [Menu/set], [*], [2], [8], [6] and [4] keys in this sequence to enter the maintenance mode. The fax machine beeps for approximately one second and displays "MAINTENANCE" on the LCD. This means the FAX is in the initial stage of the maintenance mode.
2. Press [1] and [0] keys in this order. "WSW00" is displayed on the LCD.
3. "Press [1] and [3] keys in this order. "WSW13=X1X2X3X4X5X6X7X8" appears on the LCD. (default: WSW13=01011011)
4. Press [0], [0], [0], [1], [1], [0], [1], [0] and [Menu/Set] keys in this order. (WSW13=00011010) "WSW00" appears after pressing [Menu/Set] key.
5. Press [Stop/Exit] key to return the machine to the initial stage of the maintenance mode.
6. Press [9] key twice to exit from the maintenance mode and return to standby.

1.6 Telephone FC755D1 (Option)

General

The telephone can be installed on a desktop or a bulkhead. Select a location where the telephone can easily be operated.

  • For installation on a wooden table, use the mounting base and self-tapping screws (supplied).
  • For installation on a steel table, fix the telephone with nuts and bolts.
  • For bulkhead mounting, use the bulkhead mounting base (supplied with telephone accessories).

Mounting location

Select a location where temperature and humidity are moderate and stable. Secure sufficient space around the unit for ease of operation and maintenance.

Page 24 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — How to mount
Page 24 · click to enlarge
Page 24

How to mount

Mounting base (DesktopUse installation materials, Bulkhead: Use telephone accessories.)

The mounting dimensions are shown in the outline drawing at the back of this manual. Determine the mounting loca- tion, leaving sufficient space around the unit, and then fix the mounting base to the mounting location. The mounting base is different for bulkhead and desk- top mounts, however the mounting pro- cedure is the same for all.

Secure mounting base with tapping screws.

1. Set the mounting base to the mounting location with four self-tapping screws (4x16).

Attach handset fixture here.

Furuno FleetBroadband 500 (FELCOM 500) — How to mount diagram (page 24)
Fig. 6 · How to mount

Unfasten this screw.

2. On the bottom of the telephone, release the screw shown in the figure. (The screw may be discarded.) Attach the vulcanizing tape (supplied) to the handset fixture. Fasten the handset fixture to the bottom of the telephone with a screw (3x14, supplied).
3. The catch in the receiver cradle functions to hang up the handset. Set the catch in the upward position. To detach the handset from the hanger, slide the handset upward.)
4. Set the telephone to the four catches in the mounting base, then slide it toward you until you hear a click.
5. Attach the "SLIDE" label (supplied) to the handset.
6. Attach the label (16-007-6927-0) for compass safe distance as shown below.
Furuno FleetBroadband 500 (FELCOM 500) — How to mount diagram (page 24)
Fig. 7 · How to mount
7. Set the line type of telephone to PB (Push Button) type from DP (Dial Pulse) type as follows.
Show 6 more labels / short text on this page
Catches · Bottom view · Mounting base stopper · Handset fixture · Catch · Label (16-007-6927-0)
Page 25 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — OFF
Page 25 · click to enlarge
Page 25
1. Remove the plastic sheet and recording sheet.

Remove plastic sheet and recording sheet.

2. Set #1 DIP switch to ON (PB side).

Bell off PB䇭S

ON

Set #1 to ON (PB). 1 2 3 4

OFF

DP L

3. Reattach the plastic sheet and recording sheet.

Line type · Side tone

Page 26 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 26 · click to enlarge
Page 26

2. CONNECTIONS

2.1 Standard Connection

Run and connect cables, refering to the figure below and the interconnection diagram (page S-1).

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 26)
Fig. 8

1 2 3 4 TEL 1 2 3 4

MOD-Z072, 5 m/2 m/10 m FR-FTPC-CY, 10/20/30/50/100 m

This unit is shipped with a 15 A fuse fitted in the power cable, which is for use with 12 VDC ship’s battery. For 24 VDC power, replace the fuse with a 7 A fuse and attach the “7A” label (supplied) to the power cable. Use of wrong fuse can result in damage to the equipment.

Page 27 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 27 · click to enlarge
Page 27

2. CONNECTIONS

2.2 Antenna Cable

Run the antenna cable (coaxial cable 8D-FB-CV, 30 m, 40 m or 50 m supplied) between the an- tenna unit and communication unit . Attach the connector plug of the antenna cable to the antenna unit. Connect the coaxial connector (8D-FB-CV) to the other end of the antenna cable.

Wrap the junction point of connectors with the self-adhesive tape then vinyl tape. Bind the ends of tape with a cable tie (local supply). Fix the cable to the mast with a cable tie (local supply).

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 27)
Fig. 9
Page 28 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 28 · click to enlarge
Page 28

2. CONNECTIONS

How to attach the antenna cable connector N-P-8DFB-CF

Attach the coaxial plug (supplied) to the other end of the coaxial cable to connect to the CU as follows.

(Dimensions in millimeters.)

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 28)
Fig. 10

Armor Inner Sheath Shield

Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left.

Cover with heat-shrink tubing and heat.

Remove insulator and core by 10 mm.

Twist shield end.

Slip on clamp nut, gasket and clamp as shown left.

Fold back shield over clamp and trim.

Trim shield here.

Cut aluminum foil at four places, 90 from one another.

Fold back aluminum tape foil onto shield and trim.

Trim aluminum tape foil here.

Expose the insulator by 1 mm.

Expose the conductor (core) by 5 mm.

Slip the pin onto the conductor. Solder them together through the hole on the pin.

Insert the pin into the shell. Screw the clamp nut into the shell. (Tighten by turning the clamp nut. Do not tighten by turning the shell.)

Solder through the hole.

Show 8 more labels / short text on this page
Outer Sheath · Clamp Nut · Gasket (reddish brown) · Clamp · Aluminum Foil · Insulator · Pin · Shell Clamp Nut
Page 29 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 29 · click to enlarge
Page 29

2. CONNECTIONS

How to attach the antenna cable connector N-SP-12DSFA-CF

If the optional coaxial cable 12D-SFA-CV (100 m) is used, attach the optional coaxial plug N-SP- 12DSFA-CF as follows.

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 29)
Fig. 11

Dimensions in millimeters.

Armor Inner Sheath Shield

Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left.

Twist shield end.

Slip on clamp nut, gasket and clamp as shown left.

Expose the insulator by 2 mm.

Expose the core by 4 to 5 mm.

Slip the pin onto the conductor. Solder them together through the hole on the pin.

Insert the pin into the shell. Screw the clamp nut into the shell. (Tighten by turning the clamp nut. Do not tighten by turning the shell.)

Solder through the hole.

Show 6 more labels / short text on this page
Outer Sheath · Clamp Nut · Gasket Clamp · Washer · Pin · Clamp Nut
Page 30 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — TEL 1 2 3 4
Page 30 · click to enlarge
Page 30

2. CONNECTIONS

2.3 Communication Unit

Telephone FC755D1 and Facsimile FAX-2820

Connect the cable from the telephone or facsimile to TEL1, 2, 3 or 4 port of the communication unit. The modular connector can be connected directly to the TEL1 or TEL2 as shown in the fig- ure below.

To connect to the TEL3 or TEL4, use the modular jack box (optional supply) or the modular jack set (optional supply). Connect TTYCS-1 (Japan Industry Standard cable, or equivalent, local sup- ply) between the modular jack box and communication unit. Attach two crimp-on lugs (FV1.25-3 red, supplied with the modular jack box) to the modular jack box side of the above cable

ALARM NMEA RS-232C

L-BAND OUT

LAN ANT

1 2 3 4 TEL 1 2 3 4

12-24 VDC 12-6A

3 GND

TEL3,4 No. Signal 1 TEL4 TIP 2 TEL4 RING 3 TEL3 TIP 4 TEL3 RING #4

TEL 1 2 3 4

Twisted pair cable TTYCS-1

Cable with modular plug

See below for cable fabrication.

Modular jack box MJ-2S

Cable with modular plug

Show 8 more labels / short text on this page
Communication unit FB-2000 · #1 · FMC connector · Telephone FC755D1 · Crimp-on lug · Telephone FC755D1 · Facsimile FAX-2820 · Facsimile FAX-2820
Page 31 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — NMEA signal, External alarm
Page 31 · click to enlarge
Page 31

2. CONNECTIONS

TTYCS-1 Cable fabrication

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 31)
Fig. 12

Procedure to insert wire 1. Twist core. 2. Push spring-loaded catch with slotted-head screwdriver. 3. Insert core into hole. 4. Release the screwdriver. 5. Pull wire to confirm it is securely inserted.

NMEA signal, External alarm

Furuno FleetBroadband 500 (FELCOM 500) — NMEA signal, External alarm diagram (page 31)
Fig. 13 · NMEA signal, External alarm

1 2 3 4 TEL 1 2 3 4

NMEA No. Signal 1 TD-A 2 TD-B 3 RD-A 4 RD-B 5 GND

ALARM No. Signal 1 NC-A 2 NC-B 3 GND

See the figure on previous page for how to fix FMC connector.

NMEA input sentence GGA, GLL, GNS, RMA, RMC, VTG, ZDA (Talkers for GNS are GN, GP and GL only. For other sentences any talker will do.)

Page 32 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 32 · click to enlarge
Page 32

2. CONNECTIONS

Cable fixture

To connect the LAN and TEL lines, attach the cable fixture (supplied) to the rear panel of the com- munication unit. Then insert the connectors to each port. Fasten each cable with a cable tie (sup- plied) to the cable fixture. Connect the braided shield wire of each cable to the ground terminal.

Ground terminal (Connect copper strap & braided shield of each cable)

Fasten cable to this post of cable fixture with a cable tie.

Flat washer Copper strap Crimp-on lug Flat washer Spring washer Wing nut

Cable fixture

Page 33 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Never connect as follows:
Page 33 · click to enlarge
Page 33

2. CONNECTIONS

2.4 Notice for network connection

With a hub(s), FELCOM500/FELCOM250 can establish a network configuration. If the hub(s) is connected in loop form, the FELCOM500/FELCOM250 may not function normally.

Never connect as follows:

LAN LAN LAN

LAN

[Hub 2 sets] [Hub 3 sets]

  • Use a straight connection cable for an MDI to MDI-X connection.
  • Use a cross connection cable for an MDI to MDI or MDI-X to MDI-X connection.

Generally, it is advisable to use an auto MDI/MDI-X switching hub.

Show 10 more labels / short text on this page
Communication unit FB-2000 · Communication unit FB-2000 · Communication unit FB-2000 · Hub · Hub · Hub · [Hub 1 set] · Hub · Hub · Hub
Page 34 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — How to install the connector cover
Page 34 · click to enlarge
Page 34

2. CONNECTIONS

2.5 Desktop Installation of Communication Unit tocomply with IPX2 (dripping) standard

How to inset the grommet

Be sure to install the Communication Unit to a desktop to protect from dripping. After installing, affix the grommets over the mounting screws.

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 34)
Fig. 14

How to install the connector cover

After connecting the cables, perform the following to affix the connector cover.

1. Peel off the double sided tape (white) from the connector cover.
Furuno FleetBroadband 500 (FELCOM 500) — How to install the connector cover diagram (page 34)
Fig. 15 · How to install the connector cover
2. Plug the guide rail of the connector cover into the slots as shown, and pull slightly to hook into the slot.
Page 35 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 2. CONNECTIONS
Page 35 · click to enlarge
Page 35

2. CONNECTIONS

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 35)
Fig. 16
3. With the connector cover rail in the slot, raise the connector cover in the direction of the arrow as shown below.
4. Push the connector cover in towards the triangle mark on the center top of the Communication Unit to affix.
Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 35)
Fig. 17

As seen from above (push in towards mark䋩

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 35)
Fig. 18
Page 36 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — WHT/ORG 1
Page 36 · click to enlarge
Page 36

2. CONNECTIONS

2.6 LAN Cable Fabrication

Fabricate an optional LAN cable (FR-FTPC-CY 10, 20, 30, 50 or 100 m) as follows. Cut armor and outer vinyl sheath as shown below and then connect the modular connector MPS588-C (option) to both ends.

Inner vinyl sheath Outer vinyl sheath

approx. 9mm

Expose inner vinyl sheath.

Remove the outer sheath by approx 25 mm. Be careful not to damage inner shield and cores.

Fold back the shield, wrap it onto the outer sheath and cut it, leaving 9 mm.

approx. 9mm approx. 11mm

Insert the cable into the modular plug so that the folded part of the shield enters into the plug housing. The drain wire should be located on the tab side of the jack. 7

Fold back drain wire and cut it, leaving 9 mm.

Straighten and flatten the core in order and cut them, leaving 11 mm.

Furuno FleetBroadband 500 (FELCOM 500) — 2. CONNECTIONS diagram (page 36)
Fig. 19

Using special crimping tool MPT5-8 (PANDUIT CORP.), crimp the modular plug. Finally check the plug visually.

[Crose cable] [Straight cable]

1 WHT/GRN 2 GRN 3 WHT/ORG 4 BLU 5 WHT/BLE 6 ORG 7 WHT/BRN 8 BRN

WHT/ORG 1

1 WHT/ORG 2 ORG 3 WHT/GRN 4 BLU 5 WHT/BLE 6 GRN 7 WHT/BRN 8 BRN

WHT/ORG 1

ORG 2 WHT/GRN 3

ORG 2 WHT/GRN 3

BLU 4 WHT/BLE 5

BLU 4 WHT/BLE 5

GRN 6 WHT/BRN 7

GRN 6 WHT/BRN 7

BRN 8

BRN 8

Show 4 more labels / short text on this page
Armor 150 · Wrap vinyl tape · 25mm · Drain wire
Page 37 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — FELCOM_FB
Page 37 · click to enlarge
Page 37

3. SETTING AFTER INSTALLATION

This chapter shows how to enter basic settings, done by the installation technician. For the net- work setting, request to an administrator of the ship network. (Refer to the Operator's Manual for details.)

The SIM card is required to communicate via a satellite, but not required for the following system settings. "(SIM): No SIM detected" appears in the Web software screen. Disregard the warning.

3.1 Preparation for Setting

1. Turn on the PC and insert the CD-ROM (supplied with accessories) in the PC.
2. Open the CD-ROM and copy "FELCOM_FB" shortcut icon to the desktop of the PC. This shortcut icon accesses the FELCOM 500/FELCOM 250 (IP address 192.168.1.1) through the Internet Explorer.
3. Connect the PC to the Communication unit with a LAN cable.
4. Turn on the Communication unit. The initialization begins. Wait until all STATUS LEDs light. During this time, the PC cannot access the Communication unit. Wait for a while.

I POWER 1 TX 2 3 4

READY

POWER OFF BEFORE INSERTING

OR REMOVING SIM

SIM CARD INSIDE

POWER

5. To set the IP address of the PC, select "Obtain an IP address automatically" in the Internet Protocol (TCP/IP) Preperties. If you set manually, set IP address according to the IP address of the communication unit (default 192. 168.1.1).
6. Double-click the "FELCOM_FB" shortcut icon on the PC desktop.
Furuno FleetBroadband 500 (FELCOM 500) — I POWER 1 TX 2 3 4 diagram (page 37)
Fig. 20

FELCOM_FB

Show 6 more labels / short text on this page
Power switch · STATUS Inmarsat FleetBroadband · ― · ○ · ○ · Communication unit
Page 38 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 㪝㪸㫏
Page 38 · click to enlarge
Page 38

3. SETTING AFTER INSTALLATION

The browser starts and the main menu of the Web software in the FELCOM 250/500 opens.

Administrator Login For FELCOM250, “FELCOM250” is indicated.

7. Click the Administrator Login button on upper right hand side on the screen.The Login window opens.
8. Key in username "Admin" and password "01234567"(default value).The administrator can change the password in another menu.

㪝㪸㫏

㪲㪻㪙㪆㪟㫑㪴

9. Click the Login button. New menu items appear on the menu bar; Settings, Device, Log, and Selftest.
Page 39 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 39 · click to enlarge
Page 39

3. SETTING AFTER INSTALLATION

10. Click Settings on the menu bar. The sub menu appears on left side and current setting appears in the Information window on right side.
11. Click Basic settings on the sub menu. The sub menu of the Basic settings appears

Basic settings sub menu

Use these sub menus to set the basic settings, following the procdeures on the next several pages.

Basic settings Settings · Basic settings

Page 40 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — GPS
Page 40 · click to enlarge
Page 40

3. SETTING AFTER INSTALLATION

3.2 GPS Setting

1. Click GPS on the Basic settings sub menu.

GPS

Furuno FleetBroadband 500 (FELCOM 500) — GPS diagram (page 40)
Fig. 21
2. If an external GPS is connected to the NMEA port on the communication unit, set the baud rate to 4800 bps or 38400 bps according to the GPS connected.
3. Click the Apply button.
4. To monitor output sentences from the GPS, select a GPS among Internal GPS, NMEA port, and None. "None" displays no sentences.
Page 41 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 41 · click to enlarge
Page 41

3. SETTING AFTER INSTALLATION

3.3 Analog Port Setting

Set for analog telephones/faxes that are connected to the TEL ports as follows.

1. Click Analog ports on the Basic settings sub menu.
2. In the Type box, select the equipment that is connected to the TEL port. There are four TEL ports (TEL 1 to TEL 4), TEL 1 is analog port 1 in the table. The selections are as follows;
  • TEL: Analog telephone
  • FAX: Facsimile
  • TEL & FAX: Facsimile telephone
  • No Connection: Nothing connected
3. Key in extension telephone number in the Number box. The setting range is between 1000 and 9999.
4. In the Note box, key in a name; user name, setting location, etc. This is the name a called party sees. Up to 50 alphanumeric characters can be used. Do not use symbols, "?", "/", etc.
5. Click the Apply button to finish.Do this procedure for each analog port. A number can not be set more than once.

Analog port

Page 42 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 42 · click to enlarge
Page 42

3. SETTING AFTER INSTALLATION

3.4 Incoming Indicator Setting

If the optional Incoming Indicator is connected, set it as follows.

1. Click Incoming Indicator in the Basic settings sub menu.
2. Select the ringing pattern of the incoming indicator in the "Ringing pattern of each service", between same pattern and Different pattern. Same pattern: Same ringing pattern for any communication service. Different pattern: Different ringing pattern for each communication service.
3. Check a communication services to ring the incoming indicator.
  • Voice: Ring for incoming telephone.
  • FAX: Ring for incoming facsimile.
  • ISDN UDI: Ring for incoming ISDN UDI data communication (FELCOM500 only) .
  • ISDN RDI: Ring for incoming ISDN UDI data communication (FELCOM500 only).
4. Click the Apply button to conclude the setting.

Incoming Indicator

Page 43 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 43 · click to enlarge
Page 43

3. SETTING AFTER INSTALLATION

3.5 Serial Port Setting

Set for the equipment that is connected to the RS-232C port.

1. Click Serial port in the Basic settings sub menu.
2. Select a baud rate from the Baud rate drop-down list. The selections are 9600, 19200, 38400, 57600 and 115200 bps.
3. Set a parity bit in the Parity box. The selections are None, Even and Odd.
4. Select the Flow control among Hardware, Software and None.
5. Click the Apply button to complete the setting.

Serial port

Page 44 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 44 · click to enlarge
Page 44

3. SETTING AFTER INSTALLATION

3.6 Satellite Setting

The three satellites are named APAC (Asia-pacific), EMEA (Europe-Middle east-Africa) and AMER (America). To change satellite name, do as follows.

1. Click Satellite in the Basic settings sub menu.
2. Put the cursor in the Name box and enter the name of the satellite (max. 10 characters).
3. Click the Apply button to complete the setting. The meaning of the table items is as follows.
  • ID: Identification of the satellite
  • Position: Position of the geostationary satellite (longitude)
  • Primary: Frequency of the first global channel of the satellite
  • Alternate: Frequency of the second global channel of the satellite

Satellite

Page 45 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — OTA
Page 45 · click to enlarge
Page 45

3. SETTING AFTER INSTALLATION

3.7 OTA Setting

OTA stands for Over The Air. The OTA function permits remote management of files in the SIM card.

1. Click OTA in the Basic setting sub menu.

OTA

2. To enable the OTA, click the Enabled radio button. To disable the OTA, click the Disabled radio button.
3. Click the Apply button to complete the setting. With Enabled, OTA functions as follows.

a) User requests a change of contract contents to a SIM maker.

b) The SIM maker transmits an OTA message to the terminal.

c) The terminal receives the OTA message and modifies the internal parameters according

to the contract contents.

Page 46 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Web software setting
Page 46 · click to enlarge
Page 46

3. SETTING AFTER INSTALLATION

3.8 Handset Setting

To use the IP handset, set the Web software and the IP handset as follows.

Web software setting

1. Click Settings in the menu bar.
2. Click PBX Settings in the Settings sub menu at the left side of the screen.
3. Click Extension in the PBX Setting sub menu.
4. Click the Add extension button. The following window appears. The lowest unregistered number between 1000 and 9999 appears in the Number box. To use this number, go to step 6. To register a different number, go to step 5.
5. Key in a new extension number in the Number box (1000-9999). You cannot use a number that is already entered. If you enter the same number, an error message will appear at the registration.
6. Key in a password in the Password box (a maximum of eight alphanumeric characters). Upper case alphabet can be used. Note: Do not forget to write down the telephone number and password.
7. If necessary, enter a comment in the Note box (a maximum of 50 characters), for example, user name, setting location, etc.
8. Click the Add button. The message "Completed" appears.
9. Click the OK button. The registered number appears on the Extension screen.
10. To register multiple telephones, repeat steps 4 to 9.
Page 47 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 7 PQRS
Page 47 · click to enlarge
Page 47

3. SETTING AFTER INSTALLATION

Setting in the IP handset

1. Push the Enter key at the idle screen to show the main menu.
Furuno FleetBroadband 500 (FELCOM 500) — 3. SETTING AFTER INSTALLATION diagram (page 47)
Fig. 22

CLR

2. Push 6 to select the Settings icon and then push the Enter key to show the Settings menu.
1. @

2 ABC 3 DEF

4 GHI

5 JKL

6 MNO

Furuno FleetBroadband 500 (FELCOM 500) — 2 ABC 3 DEF diagram (page 47)
Fig. 23

7 PQRS

8 TUV

9 WXYZ

3. Push 3 key to show the SIP menu.
Furuno FleetBroadband 500 (FELCOM 500) — 7 PQRS diagram (page 47)
Fig. 24
4. Push 1 key to show the Client setting screen.
Furuno FleetBroadband 500 (FELCOM 500) — 7 PQRS diagram (page 47)
Fig. 25

ENTER Key · 0 * #

Page 48 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 48 · click to enlarge
Page 48

3. SETTING AFTER INSTALLATION

5. With the Phone number box highlighted in blue, push the Enter key to show the phone number input screen.
Furuno FleetBroadband 500 (FELCOM 500) — 3. SETTING AFTER INSTALLATION diagram (page 48)
Fig. 26
6. Enter the extension number that is registered in the Web software and push the Enter key. If something has been registered, push the CLR key to erase it.
7. Push T to select Password and then push the Enter key.
8. Enter the password which was registered in the Web software and then push the Enter key.If

the password contains both alphabet and numerals, switch input format with the soft key .

Furuno FleetBroadband 500 (FELCOM 500) — 3. SETTING AFTER INSTALLATION diagram (page 48)
Fig. 27
9. Push the soft key (Apply).

The message "Set" appears and the setting for one IP handset is completed.

10. Push the CLR key three times to return to the idle screen.
11. If multiple handsets are connected, repeat the above step 1 to 10 for each handset.

When the Web software-set extension number matches handset-set extension number, the mark with a blue circle appears in the Settings/ PBX settings/ Extension window of the Web software.

Page 49 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — 3. SETTING AFTER INSTALLATION
Page 49 · click to enlarge
Page 49

3. SETTING AFTER INSTALLATION

These handsets can be used for communication. However, the following screen does not update automatically. Press the Reload button of the browser to refresh the screen.

Page 50 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — AP-1
Page 50 · click to enlarge
Page 50

APPENDIX 1 JIS CABLE GUIDE

Cables listed in the manual are usually shown as Japanese Industrial Standard (JIS). Use the following guide to locate an

equivalent cable locally.

JIS cable names may have up to 6 alphabetical characters, followed by a dash and a numerical value (example: DPYC-2.5). For core types D and T, the numerical designation indicates the cross-sectional Area (mm2) of the core wire(s) in the cable. For core types M and TT, the numerical designation indicates the number of core wires in the cable.

Ethylene Propylene 2. Insulation Type 1. Core Type

3. Sheath Type

D

Double core power line

P Y

DPYC

T

Triple core power line

M

TT

0.75mm twisted pair communications (1Q = quad cable)

4. Armor Type 5. Shielding Type 6. Core Sheath

TPYC

C Y S

All cores in one sheath

-S

MPYC-5

1 2 3 4 5 6 MPYC - 5

1 2 3 4

DPYCYS - 1.5 EX:

Designation type Core Area (mm ) Designation type # of cores

TTYCS-4

The following reference table lists gives the measurements of JIS cables commonly used with Furuno products:

1.5mm2 1.56mm 14.5mm

DPYC-1.5 1.5mm2 1.56mm 11.7mm

TPYCY-1.5

DPYC-2.5 2.5mm2 2.01mm

12.8mm

TPYCY-2.5

2.5mm2 2.01mm 15.5mm

DPYCY-2.5

2.5mm2 2.01mm 14.8mm

TPYCY-4

4mm2 2.55mm 16.9mm

DPYCYS-1.5

1.5mm2 1.56mm 14.6mm

TPYCYS-1.5

1.5mm2 1.56mm 15.2mm

DPYCYS-2.5

2.5mm2 2.01mm 15.5mm

MPYC-2

1.29mm 10.0mm

MPYC-4

1.29mm

11.2mm

1mm2 1.29mm 13.2mm

MPYC-7

MPYCY-12

1mm2 1.29mm 19.0mm

MPYCY-19

22.0mm 1mm2 1.29mm

TTYCS-1

0.75mm2 1.11mm 10.1mm

TTYCS-1Q

0.75mm 1.11mm 2

11.3mm

TTYCS-4

0.75mm 1.11mm 2

16.3mm

0.75mm 1.11mm 2

TTYCYS-1

21.1mm

AP-1

Show 12 more labels / short text on this page
Vinyl · 1mm Multi core · Corrosive resistant Steel · Individually sheathed cores · Core Cable · Core Cable · Diameter · Diameter · Type Area Diameter · Type Area Diameter · 1mm2 · 1mm2
Page 51 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 51 · click to enlarge
Page 51
Furuno FleetBroadband 500 (FELCOM 500) — PACKING LIST diagram (page 51)
Fig. 28

0#/' 176.+0' 3 6; &'5%4+26+10%1&'ͳ 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 #3: ($#,'ޔ$,'

Page 52 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 52 · click to enlarge
Page 52
Furuno FleetBroadband 500 (FELCOM 500) — PACKING LIST diagram (page 52)
Fig. 29
Page 53 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 53 · click to enlarge
Page 53
Furuno FleetBroadband 500 (FELCOM 500) — PACKING LIST diagram (page 53)
Fig. 30
Page 54 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 54 · click to enlarge
Page 54
Furuno FleetBroadband 500 (FELCOM 500) — PACKING LIST diagram (page 54)
Fig. 31
Page 55 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 55 · click to enlarge
Page 55
Furuno FleetBroadband 500 (FELCOM 500) — PACKING LIST diagram (page 55)
Fig. 32
Page 56 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 56 · click to enlarge
Page 56
Page 56 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — PACKING LIST
Page 57 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Outline Drawing
Page 57 · click to enlarge
Page 57
Furuno FleetBroadband 500 (FELCOM 500) — Outline Drawing diagram (page 57)
Fig. 33 · Outline Drawing
Page 58 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Outline Drawing
Page 58 · click to enlarge
Page 58
Furuno FleetBroadband 500 (FELCOM 500) — Outline Drawing diagram (page 58)
Fig. 34 · Outline Drawing
Page 59 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-3
Page 59 · click to enlarge
Page 59

D-3

Furuno FleetBroadband 500 (FELCOM 500) — D-3 diagram (page 59)
Fig. 35
Page 60 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-4
Page 60 · click to enlarge
Page 60

D-4

Furuno FleetBroadband 500 (FELCOM 500) — D-4 diagram (page 60)
Fig. 36
Page 61 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-5
Page 61 · click to enlarge
Page 61

D-5

Furuno FleetBroadband 500 (FELCOM 500) — D-5 diagram (page 61)
Fig. 37
Page 62 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — Outline Drawing
Page 62 · click to enlarge
Page 62
Furuno FleetBroadband 500 (FELCOM 500) — Outline Drawing diagram (page 62)
Fig. 38 · Outline Drawing
Page 63 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-7
Page 63 · click to enlarge
Page 63

D-7

Furuno FleetBroadband 500 (FELCOM 500) — D-7 diagram (page 63)
Fig. 39
Page 64 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-8
Page 64 · click to enlarge
Page 64
Furuno FleetBroadband 500 (FELCOM 500) — Outline Drawing diagram (page 64)
Fig. 40 · Outline Drawing

D-8

Page 65 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — D-9
Page 65 · click to enlarge
Page 65

D-9

Feb.15'06 T.Matsuguchi

Page 66 of the Furuno FleetBroadband 500 (FELCOM 500) user manual — S-1
Page 66 · click to enlarge
Page 66

S-1

Furuno FleetBroadband 500 (FELCOM 500) — S-1 diagram (page 66)
Fig. 41
Show 4 more labels / short text on this page
# · $ · % · &

Ask about the Furuno FleetBroadband 500 (FELCOM 500)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Furuno FleetBroadband 500 (FELCOM 500)

Be the first to ask — other owners or our team will answer.

Original document

Furuno FleetBroadband 500 (FELCOM 500) manual PDF

66 pages·6.5 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…