MT104-108
6-IN, 1-OUT S-VIDEO SWITCHER
CARD FOR MULTI-TASKER™
ENCLOSURES USER’S GUIDE




Please read this manual carefully before using your MT104-108. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT104-108 and to prevent fire and shock hazard. Please read them carefully and heed all warnings.


TECHNICAL SPECIFICATION 3
MT104-108 6-in 1-out S-Video Switcher Card
The MT104-108 is a 6-in (+1 internal input) 1-out S-Video Switcher Card designed for use in Multi-Tasker enclosures. The MT S-Video SW card enables 6 S-Video sources to be connected and switched to a single display or recording device. The MT104-108 is compatible with NTSC, PAL and SECAM S-Video signals.
The MT104-108 card utilizes solid state switching technology, and offers video bandwidth of 350 MHz, enabling it to pass high-resolution video signals without degradation. Inputs are selected via easy-to-use ASCII commands from a control system or computer connected to the RS-232 port of a Multi-Tasker™ enclosure.
Additionally, VIS (Vertical Interval Switching) capability may be added by special order. This is a feature that eliminates the "glitch" normally associated with video switching when all input video signals are gen-locked together. Also available through ASCII control is “on-off” output control.





![Page 7 of the Altinex MT104-108 user manual — 1. [VER]](/cdn/reader/ef/ef7633de2c3c4f2da730bc2dad84c749af93ea253813a1ba3c7160391e551ce0/images/page-7.webp?w=400)
Commands not ending in "S" will still be executed but will not be restored when the system is reset (power off & power on again).
slot in the Multi-Tasker™ Enclosure in order to connect to the bus. Make sure that the MT104-108 card fits into place. Secure the card to the Multi-Tasker™ by tightening the retainer screws located on the top and bottom of the MT104-108 card.
Each command consists of three parts: Function, card ID, and unit ID. [Function, Card ID, Unit ID]
VER = Function C3 = Card ID U2 = Unit ID
indicating that the card is in full operation.
source to the input connector of the MT104-108. Connect the output connectors of the MT104-108 to the display devices through a coaxial cable.
For Function, see a detailed explanation under each command description.
The Card ID is an assigned value from 1 to 19, 1 to 8, or 1 to 4 depending on which enclosure is being used. The Card ID represents the slot number where the board resides. Card ID 0 (C0) is used for the controller (see user’s guide for the MT100-100). Changing the position of a card will significantly affect the commands recorded on software definitions or a third party control system.
number where the MT104-108 card is plugged into the Enclosure and note that it is for RS-232 control.
7.1 RS-232 CONTROL
When used in the Multi-Tasker™ Enclosure, the MT104-108 has many advanced remote control capabilities, which are accessible through standard RS-232 communication. The actual controlling can be accomplished through a computer control system or any other device capable of sending RS-232 commands.
The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to 0, then each command can be used without Ui (use command [SETU0]; see user’s guide for the MT100-100).
[VERC3]: for unit ID zero [VERC3Ui]: for unit ID other than zero [VERC3]: equivalent to [VERC3U0]
The RS-232 commands for the MT104-108 are in a simple ASCII character format.
This command receives the software version
and card type for the MT104-108 card.
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.
Cn = card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation)
Commands such as [ON], [OFF], and [IO] that end in "S" will be saved into memory.
![Page 8 of the Altinex MT104-108 user manual — 4. [ON]](/cdn/reader/ef/ef7633de2c3c4f2da730bc2dad84c749af93ea253813a1ba3c7160391e551ce0/images/page-8.webp?w=400)
One MT104-108 card is in slot #2 of unit 3: Send the command [VERC2U3] and the Multi-Tasker™ Enclosure will return:
This command enables input “m” and disables all other inputs.
Default when plugged in = Input 1 is ON
MT104-108 = card type 690-0160-002= software version
m = Input number (m = 1 to 7, 7 is internal)
Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID number (i = 0 to 9) S = saves command to memory
This command receives the status of the card.
Cn = card ID (n = # from 1 to max slots)
If all of the inputs on the MT104-108 card are OFF and the card is in slot #5 of unit 3:
Ui = unit ID (i = from 0 to 9) ( refer to the MT100-100 user’s guide for explanation)
An MT104-108 card is in slot #2 of unit 3 and input 1 is ON. Sending the command [C2U3] will yield the following feedback from the Multi-Tasker™:
This command enables input "m" for each card in group "k" of unit "i".
m = Input (m = 1 to 7, input 7 is internal) Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) S =saves command to memory
If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback.
[ON1G1U1]: Turns ON input 1 for each card in group 1 of unit 1.
This command saves the current status of the card's input selection configuration. This configuration will be restored after system is reset or powered off then on.
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded and then all switched at the same time.
Cn = card number S = save configuration
If Inputs 1,2,3,4,5 and 6 are enabled, the feedback after sending the command [C4S], for slot 4, would be:
ON:1,2,3,4,5,6 C04 Saved
m = Input number (m = 1 to 7, 7 is internal) Cn = card ID (n = slot # from 1 to max slots) Ui = Unit ID number (i = 0 to 9) P = path
This command enables one input of a single card or a group of cards.
![Page 9 of the Altinex MT104-108 user manual — [OFF1C6U3 P ] [OFF3C7U3 P ] [SW]](/cdn/reader/ef/ef7633de2c3c4f2da730bc2dad84c749af93ea253813a1ba3c7160391e551ce0/images/page-9.webp?w=400)
m = Input (m = 1 to 7, 7 is internal) Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID number (i = 0 to 9) S = saves command to memory
There are two MT104-108 cards in slots 6 and 7 of unit 3. Enable input 1 of card 6 and input 3 of card 7 simultaneously. Use the following commands:
If "F" is included, use the [ONmCnUiPF] command or the [ONmCnUiFP] command.
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. Then, all connection may be made simultaneously.
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.
m = Input (m = 1 to 7, 7 is internal) Cn = card ID (n = slot # from 1 to max slots) Ui = Unit ID number (i = 0 to 9) P = path
This command disables one input of a single card or a group of cards.
This command disables input “m” or all inputs. The command [OFFC5CnUi], turns OFF all inputs of the MT104-108 card.
There are two MT104-108 cards in slot 6 and 7 of unit 3. Enable input 1 of card 6 and input 3 of card 7 simultaneously. Use the following commands:
m = Input (m = 1 to 7, input 7 is internal Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID number (i = 0 to 9) S = saves command to memory
If "F" is included, use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command.
Card 5 of unit 3 has input 1 ON. Card 6 of unit 3 has input 5 ON. The following commands can be used to turn OFF the inputs on both cards simultaneously.
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.
This command disables input "m" for each card in group "k" of unit "i".
![Page 10 of the Altinex MT104-108 user manual — 10. [HELP]](/cdn/reader/ef/ef7633de2c3c4f2da730bc2dad84c749af93ea253813a1ba3c7160391e551ce0/images/page-10.webp?w=400)
commands along with a brief description will be displayed in the Terminal Window
This command will save the configuration command being sent in memory. When sending the command [ON1C4S], after reset or power up, output 1 on C4 will be enabled.
This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups.
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.
Cn = card ID (n = slot # from 1 to max slots) Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9)
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. See examples in ON and OFF commands.
To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2 and 3 will be grouped together as group 5 of unit 1.
This command clears the members for a single group or for all nine groups.
The switch command immediately connects inputs and outputs, which were previously set with the path command. This command effects this card and all other cards in the MT100-100.
Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9)
The system will return feedback as OK if the unit ID is zero.
Cn = card ID number (n = # from 1 to max slots)
This command is used to request group data. With the command, the user can identify which input or output of a particular group is on.
Ui = Unit ID (i = # from 0 to 9) ( refer to the MT100-100 user’s guide for explanation)
This command displays information available for the Multi-Tasker interface commands.
Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9)
In order to view the RS-232 commands available for the MT104-108 card in slot 2 of unit 3, send the command [HELPC2U3]. The
In unit ID0, if group 1 has DA Cards with outputs 1 and 2 on, while group 2 has SW Cards with input 2 on:
![Page 11 of the Altinex MT104-108 user manual — 14. [RD]](/cdn/reader/ef/ef7633de2c3c4f2da730bc2dad84c749af93ea253813a1ba3c7160391e551ce0/images/page-11.webp?w=400)
[G1]: will return feedback as ON12 G1U0. [G2]: will return feedback as ON2 G2U0.
This command displays the members in each group.
Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) member = C1 - C19 (card 1 to max cards)
The cards in slots 1, 2 and 19 are part of group 5 in unit 1. Read the member data for group 5 of unit 1, by sending the command [RDG5U1]. The system will return feedback as follows:
C1C2C19 G5U1.

Cause 3: Cable connections are incorrect.
We have carefully tested and have found no problems in the supplied MT104-108; however, we would like to offer suggestions for the following:
Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.
Cause 1: Card cage is not plugged in.
Cause 4: The display has a problem.
Solution: Plug card cage in. If the LED lights, the problem is solved. If the LED is still not ON, see Cause 2.
Solution: Make sure the display has power and is turned ON. If there is still no display, please call Altinex at (714)-990-2300.
Cause 2: Card is not plugged in all the way.
Solution: Push the card in all the way. If the LED is still not ON, see Cause 3.
Cause 3: Card cage slot has a problem.
9.1 LIMITED WARRANTY/RETURN POLICY
card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.
Please see the Altinex website at www.altinex.com for details on warranty and return policy.
ALTINEX, INC
Brea, CA 92821 USA
with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.
TOLL FREE: 1-800-ALTINEX
Cause 1: The source has a problem.
Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.
Cause 2: The card output is not selected.
Solution: Select the card output. See RS-232 accessible commands in Section 7. If no display is present, see Cause 3.
592 Apollo street