EN
Frigidaire logo
Official user manual

Frigidaire KG7 Series

16 pages·1.4 MB·Furnace·PDF·ENDEFRITNLJA
Frigidaire KG7 Series
Table of Contents 34 sections Philco KG7 Series Gas Furnace Features & Benefits · WARRANTY ON PHILCO FURNACES · registered, 1 year Heat Exchanger and 1 year parts when not registered · Warranty Registration: Register your system within 60 days of installation · … ShowHide
Page 1 of the Frigidaire KG7 Series user manual — Warranty Registration: Register your system within 60 days of installation
Page 1 · click to enlarge
Page 1

Philco KG7 Series Gas Furnace Features & Benefits

  • Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct vent (2 pipe) system
  • 100% fired and tested: All units and each component are tested on the manufacturing line
  • Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
  • Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures long life
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings (60, 90, 120 and 180 seconds)
  • 30 second post purge: Increases life of heat exchanger
  • Hot surface igniter: Innovative application of an appliance igniter. Utilizes proven Smartlite® technology
  • Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service
  • High static blowers: All models equipped with high static blowers
  • 90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil
  • LP convertible: Simple burner orifice and regulator spring change for easy of convertibility
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes
  • Integrated control board: Incorporates connections for electronic air clear and humidifier
  • Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws
  • Sealed vestibule: Reduces burner and inducer sound levels
  • Extended flush jacket : Jacket provides an "appliance appearance"
  • CSA certified design
  • 115V, 60Hz. Gas connections are 1/2" NPT
Frigidaire KG7 Series — Philco KG7 Series Gas Furnace Features & Benefits diagram (page 1)
Fig. 1 · Philco KG7 Series Gas Furnace Features & Benefits
Frigidaire KG7 Series — Philco KG7 Series Gas Furnace Features & Benefits diagram (page 1)
Fig. 2 · Philco KG7 Series Gas Furnace Features & Benefits

C & L are Energy Star rated

Frigidaire KG7 Series — Philco KG7 Series Gas Furnace Features & Benefits diagram (page 1)
Fig. 3 · Philco KG7 Series Gas Furnace Features & Benefits

WARRANTY ON PHILCO FURNACES

Warranty DetailsLifetime Heat Exchanger and 10 years on all parts when product is

registered, 1 year Heat Exchanger and 1 year parts when not registered

1 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first year of operation to the original owner

Warranty Registration: Register your system within 60 days of installation

Frigidaire KG7 Series — Warranty Registration: Register your system within 60 days of installation diagram (page 1)
Fig. 4 · Warranty Registration: Register your system within 6…
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 2 of the Frigidaire KG7 Series user manual — 92+ AFUE Single Stage Gas Furnace (High Efficiency)
Page 2 · click to enlarge
Page 2

92+ AFUE Single Stage Gas Furnace (High Efficiency)

Frigidaire KG7 Series — 92+ AFUE Single Stage Gas Furnace (High Efficiency) diagram (page 2)
Fig. 5 · 92+ AFUE Single Stage Gas Furnace (High Efficiency)
  • High efficiency blower kit maximize efficiencies
  • Multi-speed direct drive blower designed to give a wide range of cooling capacities. Switches on PCB, provides ultra easy motor speed selection.
Input BtuhHP -Speed-Type-FLAR410 CoilModel NumberPart Number Upflow / Horizontal 38,0001/3 - 4 - PSC - 4.80C6BAX24(C,U)A C6BAX30(C,U)AKG7SC038D23A904639K 54,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7SC054D24B904640K 72.,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7SC072D24B904641K 72,0001/2 - 4 - PSC - 7.50C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7SC072D35C904642K 90,0001.0 - 4 - PSC - 13.75C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7SC090D35C904643K 108,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DKG7SC108D45D904644K 120,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DKG7SC120D45D904645K Downflow 54,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7SL054D24B904651K 72.,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7SL072D24B904652K 90,0001.0 - 4 - PSC - 7.50C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7SL090D35C904653K 120,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DKG7SL120D45D904654K
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 3 of the Frigidaire KG7 Series user manual — 95+ AFUE Two Stage Gas Furnace (High Efficiency)
Page 3 · click to enlarge
Page 3

95+ AFUE Two Stage Gas Furnace (High Efficiency)

  • Energy efficient brushless DC (ECM) motor
  • Control board has connections for twinning
Input BtuhHP -Speed-Type-FLAR410 CoilModel NumberPart Number Fixed Speed Upflow / Horizontal 60,0001/2 - FS - BLDC - 6.2C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7TC060D24B904727K 80,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7TC080D35C904728K 100,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7TC100D35C904729K 120,0001.0 - FS - BLDC - 11.7C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DKG7TC120D45D904730K Fixed Speed Downflow 60,0001/2 - FS - BLDC - 6.2C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BKG7TL060D24B904731K 80,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7TL080D35C904732K 100,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CKG7TL100D35C904733K 120,0001.0 - FS - BLDC - 11.7C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DKG7TL120D45D904734K
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 4 of the Frigidaire KG7 Series user manual — Warranty Registration: Register your system within 60 days of installation
Page 4 · click to enlarge
Page 4

Frigidaire FG7 Series Gas Furnace Features & Benefits

  • Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct vent (2 pipe) system
  • 100% fired and tested: All units and each component are tested on the manufacturing line
  • Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
  • Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assure a long life
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings (60, 90, 120 and 180 seconds)
  • 30 second post purge: Increases life of heat exchanger
  • Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology
  • Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service
  • High static blowers: All models equipped with high static blowers
  • 90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil
  • LP convertible: Simple burner orifice and regulator spring change for easy of convertibility
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes
  • Integrated control board: Incorporates connections for electronic air clear and humidifier
  • Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws
  • Blower compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation
  • Sealed vestibule: Reduces burner and inducer sound levels
  • Rounded corner jacket: Provides an "appliance appearance"
  • CSA certified design
  • 115V, 60Hz. Gas connections are 1/2" NPT
Frigidaire KG7 Series — Frigidaire FG7 Series Gas Furnace Features & Benefits diagram (page 4)
Fig. 6 · Frigidaire FG7 Series Gas Furnace Features & Benefit…
Frigidaire KG7 Series — Frigidaire FG7 Series Gas Furnace Features & Benefits diagram (page 4)
Fig. 7 · Frigidaire FG7 Series Gas Furnace Features & Benefit…

C & L are Energy Star rated

WARRANTY ON FRIGIDAIRE FURNACES

Warranty DetailsLifetime Heat Exchanger and 10 years on all parts when product is

registered, 20 years Heat Exchanger and 5 year parts when not registered

10 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first 10 years when registered, 1 year when not registered

Warranty Registration: Register your system within 60 days of installation

Extended Warranty ProtectionAsk your Davies Rep for specific details on labor protection plans
Frigidaire KG7 Series — Warranty Registration: Register your system within 60 days of installation diagram (page 4)
Fig. 8 · Warranty Registration: Register your system within 6…
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 5 of the Frigidaire KG7 Series user manual — 92+ AFUE Single Stage Gas Furnace (High Efficiency)
Page 5 · click to enlarge
Page 5

92+ AFUE Single Stage Gas Furnace (High Efficiency)

Frigidaire KG7 Series — 92+ AFUE Single Stage Gas Furnace (High Efficiency) diagram (page 5)
Fig. 9 · 92+ AFUE Single Stage Gas Furnace (High Efficiency)
  • Multi-speed direct drive blower designed to give a wide range of cooling capacities
  • Switches on PCB, provide ultra easy motor speed selection
Input BtuhHP -Speed-Type-FLAR410 CoilModel NumberPart Number Upflow / Horizontal 38,0001/3 - 4 - PSC - 4.80C6BAX24(C,U)A C6BAX30(C,U)AFG7SC038D23A904639F 54,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7SC054D24B904640F 72,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7SC072D24B904641F 72,0001/2 - 4 - PSC - 7.50C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7SC072D35C904642F 90,0001.0 - 4 - PSC - 13.75C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7SC090D35C904643F 108,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7SC108D45D904644F 120,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7SC120D45D904645F Downflow 54,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7SL054D24B904651F 72,0001/2 - 4 - PSC - 8.20C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7SL072D24B904652F 90,0001.0 - 4 - PSC - 7.50C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7SL090D35C904653F 120,0001.0 - 4 - PSC - 13.75C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7SL120D45D904654F
Frigidaire KG7 Series — 92+ AFUE Single Stage Gas Furnace (High Efficiency) diagram (page 5)
Fig. 10 · 92+ AFUE Single Stage Gas Furnace (High Efficiency)
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 6 of the Frigidaire KG7 Series user manual — 95+ AFUE Two Stage Gas Furnace (High Efficiency)
Page 6 · click to enlarge
Page 6

95+ AFUE Two Stage Gas Furnace (High Efficiency)

  • iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling
  • Two stage inducer optimizes efficiency on first stage heat and reduces sound levels
Input BtuhHP -Speed-Type-FLAR410 CoilModel NumberPart Number Fixed Speed Upflow / Horizontal 60,0001/2 - FS - BLDC - 6.2C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7TC060D24B904727F 80,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7TC080D35C904728F 100,0003/4 - FS - BLDC - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7TC100D35C904729F 120,0001.0 - FS - BLDC - 11.7C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7TC120D45D904730F Variable Speed Upflow / Horizontal 60,0001/2 - VS - 6.2C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7TC060DVB904735F 80,0003/4 - VS - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7TC080DVC904736F 100,0003/4 - VS - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7TC0100DVC904737F 120,0001.0 - VS - 11.7C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7TC120DVD904738F
Frigidaire KG7 Series — 95+ AFUE Two Stage Gas Furnace (High Efficiency) diagram (page 6)
Fig. 11 · 95+ AFUE Two Stage Gas Furnace (High Efficiency)
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 7 of the Frigidaire KG7 Series user manual — iQ Drive® Controller & Accessories
Page 7 · click to enlarge
Page 7

97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency)

  • iQ Drive® Modulating Heating Operation Includes: - Modulating gas valve from 100% to 50% input in 5% increments - Time proportioning modulation down to 15% - Variable speed inducer and blower
  • iQ Drive® thermostat provides modulation down to 15% and is required for furnace operation
  • iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling
Input BtuhHP -Speed-FLAR410 CoilModel NumberPart Number Fully Modulating, Variable Speed Upflow / Horizontal 60,0001/2 - Variable - 6.2C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)BFG7MQ060DVB904743F 80,0003/4 - Variable - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7MQ080DVC904744F 100,0003/4 - Variable - 8.7C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)CFG7MQ100DVC904745F 120,0001.0 - Variable - 11.7C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)DFG7MQ120DVD904746F

iQ Drive® Controller & Accessories

Frigidaire KG7 Series — iQ Drive® Controller & Accessories diagram (page 7)
Fig. 12 · iQ Drive® Controller & Accessories
  • Customizable programming options for every day, weekdays, weekends or individual days
  • On-board diagnostics alert when service or maintenance is needed
  • Smart recovery gradually adjusts indoor temperatures for greater comfort
  • Senses humidity and has a dehumidification mode that removes moisture quickly
  • Communicates to various components within the iQ Drive® System and serves as the main controller for an iQ Zone® System
  • Auto changeover automatically switches the thermostat from heating to cooling
  • No batteries required, settings are stored internally in the event of a power failure
  • Two color backlight for easy viewing
  • Energy saving features are customizable (temperature setbacks, heat pump/electric heat or furnace changeover)
DescriptionPart Number iQ Drive® Controller - Complete System Monitor & Controller920621F Accessories Individually Shielded Wire, 30m (100') 2 Pair, 4 Conductor, 22 AWG Stranded (7x30) TC Conductors, 300V RMS 60ºCB8723 Optional Outdoor Sensor920938
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 8 of the Frigidaire KG7 Series user manual — Filter Rack
Page 8 · click to enlarge
Page 8

Floor Registers - Plastic

Frigidaire KG7 Series — Floor Registers - Plastic diagram (page 8)
Fig. 13 · Floor Registers - Plastic
  • Sleek modern look with rounded corners and blades
  • Durable plastic construction, will not rust
  • Smooth, quiet damper adjustment for desired level of air flow
  • Easy to install, maintenance free
DescriptionBrandPart Number 3"x10" Register - WhiteDeflectoRF31003B 3"x10" Register - TaupeDeflectoRF31028B 3"x10" Register - BrownDeflectoRF31036B 4"x10" Register - WhiteDeflectoRF41003B 4"x10" Register - TaupeDeflectoRF41028B 4"x10" Register - BrownDeflectoRF41036B

Horizontal Conversion Kit for Frigidaire "G6" Gas Furnaces

Frigidaire KG7 Series — Horizontal Conversion Kit for Frigidaire "G6" Gas Furnaces diagram (page 8)
Fig. 14 · Horizontal Conversion Kit for Frigidaire "G6" Gas Fu…
  • For converting a 90+ upflow residential gas furnace to a horizontal left or horizontal right position
Kit IncludesBrandPart Number Installation Instructions (#707796) 1/2" barbed fitting (#663841) 2" to 1/2" PVC reducer bushing (#663840) 2" PVC tee (#663115) Tube, drain hard "J" - 5" x 2" (#663763) Tube, soft - 10" (#663764) Tube, soft - 50" (#663765) Tube, high temp, grey - 17.5" (#263965) Vinyl cap - 5/8" (#663723) Vinyl cap - 1/2" (#663684) Hose clamps (2) - 7/8" dia. (#668914) Reducer - 3" to 2" (#663692)Frigidaire903568

Horizontal installation suspended in attic or crawl space

Filter Rack

Frigidaire KG7 Series — Filter Rack diagram (page 8)
Fig. 15 · Filter Rack
  • Comes with door
Filter SizePart Number 16" x 25" x 1"FR16251 20" x 25" x 1"FR20251
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 9 of the Frigidaire KG7 Series user manual — For G7MQ Modulating Furnaces
Page 9 · click to enlarge
Page 9

Furnace Accessories

LP Gas Conversion Kits

Frigidaire KG7 Series — Furnace Accessories diagram (page 9)
Fig. 16 · Furnace Accessories
  • For G6 & L1 Series Furnaces
  • Designed for Canadian installations. To convert a natural gas furnace to LP/Propane gas for altitudes between 0 to 4,500 feet above sea level, the main gas orifice must be replaced. For higher altitudes (between 2,000 & 4,500 feet above seal level) the input must be de-rated by 10%. This can be done by simply reducing the manifold pressure without changing the gas orifices.
  • Use on standard & slow opening models only
  • Not for use with step regulator valves
ApplicationBrandPart Number For use with G6 & L1 series gas furnaces using a Honeywell Gas ValveFrigidaire904091A
  • For G7 Series Furnaces
  • Designed for Canadian installations to convert a natural gas furnace to LP/Propane gas. Used for altitudes between 0 to 4,500 feet above sea level
  • For altitudes between 0 and 1,999 feet, only the orifice needs to be changed. For altitudes between 2,000 and 4,500 feet, both the orifice and the regulator pressure need to be changed.
ApplicationBrandPart Number For use with G7 series gas furnaces using a Honeywell Gas ValveFrigidaire904915

For G7MQ Modulating Furnaces

ApplicationBrandPart Number For use with G7MQ series gas furnacesFrigidaire904950
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 10 of the Frigidaire KG7 Series user manual — This Page Left
Page 10 · click to enlarge
Page 10

This Page Left

Intentionally

Blank

Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 11 of the Frigidaire KG7 Series user manual — Flue Gas Venting System - System 636™ PVC
Page 11 · click to enlarge
Page 11

Flue Gas Venting System - System 636™ PVC

  • Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65 o C or less
  • Complete system fully certified to ULC S636
  • White pipe with unique blue certification markings made to SCH 40 dimensions
Frigidaire KG7 Series — Flue Gas Venting System - System 636™ PVC diagram (page 11)
Fig. 17 · Flue Gas Venting System - System 636™ PVC
DescriptionCasePart Number 2" Flue Gas Venting System 2" Concentric Vent Termination Kit (no vent screen)3196005 2" Wall Termination Kit (no vent screen)1081216 2" x 10' Pipe (Straight End)10194000 2" Coupling (HubxHub)70196352 2" 45o Elbow (HubxHub)110196242 2" 90o Street Elbow (SPxHub)60196232 2" 90o Long Elbow (HubxHub)55196122 2" 90o Extra Long Elbow (HubxHub)40196022 2" Sanitary Tee (HubxHubxHub)35196082 3" Flue Gas Venting System 3" Concentric Vent Termination Kit (no vent screen)3196006 3" Wall Termination Kit (no vent screen)1081219 3" x 10' Pipe (Straight End)10194001 3" Coupling (HubxHub)60196353 3" 45o Elbow (HubxHub)25196243 3" 90o Street Elbow (SPxHub)15196233 3" 90o Long Elbow (HubxHub)23196123 3" 90o Extra Long Elbow (HubxHub)15196023 3" Sanitary Tee (HubxHubxHub)17196083 Adapters & Other Components 3" x 2" Increaser Coupling (HubxHub)45196364 3" x 2" Reducer Tee (HubxHubxHub)10196822 2" x 1 1/2" Reducer Bushing (SPxHub) Used with #19627880196282 1 1/2" x 1/2" Reducer Busing (SPxHose Barb)80196278 2" Testing Plug & Bushing Kit (SPxPlug)10196143 Cement PVC Cement, Low VOC (1 pint/473ml)12196040 PVC Cement, Low VOC (1 quart/946ml)12196041 Transition Cement - To ABS Only (1 pint/473ml)12196044 Primer Primer should be used when installing System636 products at temperatures below 0oC PVC/CPVC Purple Primer, Low VOC (1 pint/473ml)12196042 PVC/CPVC Clear Primer, Low VOC (1 pint/473ml)12196017 PVC/CPVC Purple Primer, Low VOC (1qt/946ml)12196043
Frigidaire KG7 Series — Flue Gas Venting System - System 636™ PVC diagram (page 11)
Fig. 18 · Flue Gas Venting System - System 636™ PVC
  • Concentric Vent Kits
  • These "pipe-in-pipe" kits allow for both exhaust and intake pipes to penetrate the roof or side wall through only one hole and are certified with mechanically fastened rain caps
  • Screw/bolt assembly (included) for mechanically fastening the rain cap can be easily removed for cleaning or maintenance Wall Termination Kits
  • For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits require only two small wall penetrations for intake and exhaust.
  • Kits include a white finishing plate with a self sealing foam back that can be screwed to the exterior wall. Testing Plug & Bushing Kit
  • Allows an inline access point for flue monitoring using fully certified System 636 components. The kit consists of a 2" x 1/2" reducer bushing (Spig x FPT) and a removable 1/2" MPT plug.
  • May be installed in new installations or added to existing lines when monitoring is required
  • Bushing must be inserted in a 2" fitting socket
  • May be used on vent lines in any diameter
  • Certified for use only on IPEX System 636 flue gas vent lines.
Frigidaire KG7 Series — Flue Gas Venting System - System 636™ PVC diagram (page 11)
Fig. 19 · Flue Gas Venting System - System 636™ PVC
Frigidaire KG7 Series — Flue Gas Venting System - System 636™ PVC diagram (page 11)
Fig. 20 · Flue Gas Venting System - System 636™ PVC
Frigidaire KG7 Series — Flue Gas Venting System - System 636™ PVC diagram (page 11)
Fig. 21 · Flue Gas Venting System - System 636™ PVC
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Show 4 more labels / short text on this page
Concentric Vent Kit · Testing Plug · & Bushing · Kit
Page 12 of the Frigidaire KG7 Series user manual — J Hooks (Furnace Venting Accessory)
Page 12 · click to enlarge
Page 12

Condensate Water Neutralizer Kit For High Efficient Gas Furnaces

Frigidaire KG7 Series — Condensate Water Neutralizer Kit For High Efficient Gas Furnaces diagram (page 12)
Fig. 22 · Condensate Water Neutralizer Kit For High Efficient…
  • Inline cartridge that will raise or neutralize the pH level of the condensate water
  • Limestone neutralizer material should be changed yearly
DescriptionIncludesPart Number 2" Inline cartridge1/2" ID vinyl tubing, hose clamps & mounting ties902377

J Hooks (Furnace Venting Accessory)

Frigidaire KG7 Series — J Hooks (Furnace Venting Accessory) diagram (page 12)
Fig. 23 · J Hooks (Furnace Venting Accessory)
DescriptionPart Number 2" x 7 1/2" DWV Swiveling J Hook (Plastic)515-J2000 3" x 7 1/2" DWV Swiveling J Hook (Plastic)515-J3000
Davies Supply Group Ltd.Calgary (800) 661-1346Lethbridge (877) 595-7707Saskatoon (877) 355-3377 (403) 244-2161(403) 381-7707(306) 933-2433
Page 13 of the Frigidaire KG7 Series user manual — Twinning Kit For G7 Single Stage Gas Furnaces
Page 13 · click to enlarge
Page 13

Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces

Frigidaire KG7 Series — Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces diagram (page 13)
Fig. 24 · Variable Speed Blower Kits for Frigidaire "G6 & L1"…
  • 904231 kit fits all G6/L1 series gas furnaces with an "A" width cabinet. May be configured for air conditioning/heat pump airflows from 1 1/2 to 3 tons nominal capacity.
  • 904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B" & "C" width cabinets. May be field configured for air conditioning/ heat pump airflows from 2 to 5 tons nominal capacity.
  • Designed to maximize system efficiencies, improve air quality and reduce sound levels
  • Air conditioning and heat pump efficiencies up to 16 SEER and 8.5 HSPF
  • ECM (electronically commutated motor) variable speed DC motor allows for 12 selected cooling airflows and 8 heating airflows to match any applications
  • Extra low speed for "fan only" operation
  • Extra quiet and smooth blower on and off cycles
  • Warranty: Carries the balance of original equipment warranty

Fits "A" Width Cabinets for G6 & L1 series 904231 WARNING Not for use with Model Numbers: *G6RK096-12B & *GF1RK096-12B

Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series

(not suitable for "B" cabinet 1200 CFM applications) 904075

Nominal Blower Size 10" x 6" 11" x 10"

Maximum Motor HP 1/2 3/4

Motor Type Programmable Variable Speed

Cooling CFM Range* 720 to 1240 720 to 1870

Heating Airflow Range* 550 to 1215 720 to 1800

* Airflow is held constant regardless of external static pressure within the HP and RPM limits of the motor

Variable Speed Motor Tester - TECMate PRO™

Frigidaire KG7 Series — Variable Speed Motor Tester - TECMate PRO™ diagram (page 13)
Fig. 25 · Variable Speed Motor Tester - TECMate PRO™
  • Designed to assist field service technicians by troubleshooting GE ECM 2.3 motors independently of the HVAC system

TECMate Pro™ Variable Speed Motor Tester 904232

Twinning Kit For G7 Single Stage Gas Furnaces

Frigidaire KG7 Series — Twinning Kit For G7 Single Stage Gas Furnaces diagram (page 13)
Fig. 26 · Twinning Kit For G7 Single Stage Gas Furnaces
  • Provides the capability to combine the operation of two single stage gas furnaces with PSC motors (not for use with 2 stage, modulating or variable speed blower models)
  • Twinning function not backwards compatible with furnaces manufactured prior to June 2009
Frigidaire KG7 Series — Twinning Kit For G7 Single Stage Gas Furnaces diagram (page 13)
Fig. 27 · Twinning Kit For G7 Single Stage Gas Furnaces

G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After

Show 4 more labels / short text on this page
Specifications · 904231 904075 · Programmable Variable Speed · June 2009 920919
Page 14 of the Frigidaire KG7 Series user manual — This Page Left
Page 14 · click to enlarge
Page 14

This Page Left

Intentionally

Blank

Page 15 of the Frigidaire KG7 Series user manual — 8010050-3B (LFR) 5010035 (NH3)
Page 15 · click to enlarge
Page 15

Oil-Fired Forced Air Furnaces With Burner

  • 80+ AFUE
  • Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts
  • LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either side, bottom or rear
  • LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorporates the furnace, control board, motor & blower. The 24VAC powered board uses a standard external HVAC transformer, is air conditioning ready and has LED indication and diagnostic output.
  • NLF Model: For traditional replacement or new home construction requiring front flue
  • NL2 Model: For traditional replacement or new home construction requiring rear flue
  • NH3 Model: Vestibuled cabinet is approved for closet clearances
  • All Pre & Post Purge Burners can be used with a Sealed Venting System (SVS). This system allows direct venting without chimneys. Required for installation: Sealed Venting Unit, Oil Flex Vent & Air Duct.

Direct Drive Blower Motor

Description Flue Btuh Output

Burner Brand Part Number (Model Number) HP Speed

Highboy Front / Rear 81,000 3 1/3 4 F3 Riello Newmac 8010050-3* (LFR)

Highboy Front / Rear 81,000 3 1/3 4 Beckett AFG Newmac 8010050-3B* (LFR80)

Highboy Front / Rear 81,000 3 1/3 4 Beckett AFG Pre & Post Purge Newmac 8010050-3BP* (LFR)

Highboy Front / Rear 81,000 3 1/3 Variable

Speed Beckett AFG Newmac 8010081-3B* (LFR-VSM)

Highboy Front / Rear 81,000 3 1/3 Variable

Beckett AFG Pre & Post Purge Newmac 8010081-3BP* (LFR-VSM)

Lowboy Front 118,000 3.5 1/2 4 Beckett AFG Newmac 8010033DD-3B (NLF118)

Lowboy Rear 77,000 3.5 1/2 4 Beckett AFG Newmac 8010027DD-3B* (NL2)

Highboy Top 101,000 3 1/2 4 Beckett AFG Newmac 5010035 (NH3-101)

Frigidaire KG7 Series — Oil-Fired Forced Air Furnaces With Burner diagram (page 15)
Fig. 28 · Oil-Fired Forced Air Furnaces With Burner

* Energy Star Rated

Frigidaire KG7 Series — Oil-Fired Forced Air Furnaces With Burner diagram (page 15)
Fig. 29 · Oil-Fired Forced Air Furnaces With Burner

Davies also stocks a selection

of Beckett Burners. Call Davies Pros On Controls

for proper application.

8010050-3B (LFR) 5010035 (NH3)

Replacement Parts For 8010050-3B (LFR80) Furnace With Beckett AFG Burner

Description Specifications Part Number

Capacity (USgal/hr)0.50 Spray Angle: 45° - B 21566108
Capacity (USgal/hr)0.55 Spray Angle: 45° - B 21566109
Blower Unit (less Motor) Bore1/2" Fan: 10" dia. Rotation: CW 2040116T
Show 4 more labels / short text on this page
AC Rating · (tons) · Speed · Hago Nozzles
Page 16 of the Frigidaire KG7 Series user manual — 8010024G 8010001
Page 16 · click to enlarge
Page 16

Combination Oil/Gas & Wood Furnace With Beckett AFG Burner

Frigidaire KG7 Series — Combination Oil/Gas & Wood Furnace With Beckett AFG Burner diagram (page 16)
Fig. 30 · Combination Oil/Gas & Wood Furnace With Beckett AFG…
  • Separate combustion chamber for oil/gas
  • Extra large brick lined firebox
  • Pre-heated combustion air is introduced by a thermostatically controlled draft system
  • Disposable air filters
  • Warranty: 10 year limited on the heat exchanger
  • CL85/95 Model: Automatic switching from wood to oil
  • CL86/96C Model: Automatic switching from wood to oil, separate thermostats & large fire door. Burns wood without grates for better control and efficiency.
  • CL86/96G Model (Wood/Oil/Coal): Where wood or coal is available, this model gives the ultimate conservation choice. Large firebox and firedoor with shaker grates for coal.

Motor Brand Part Number (Model Number)

900/1000 82,000/94,000 1/3 HP Newmac 8010012-2B (CL85/95)

1200/1200 86,000/ 96,000 1/3 HP Newmac 8010015-2B (CL86/96C)

1200/1200 86,000/ 96,000 1/3 HP Newmac 8010014-2B (CL86/96G)

Wood Only Furnaces

Frigidaire KG7 Series — Wood Only Furnaces diagram (page 16)
Fig. 31 · Wood Only Furnaces
Frigidaire KG7 Series — Wood Only Furnaces diagram (page 16)
Fig. 32 · Wood Only Furnaces
  • WA0 Model: Is a wood add-on furnace designed for operation in conjunction with an existing residential oil furnace system with a firing rate of .75 gph to 1.10 gph. 10 year limited warranty.
  • WB100 Model: Can be used alone or in conjunction with an existing residential system. 10 year limited warranty on the heat exchanger.

Motor Brand Part Number (Model Number)

1200 100,000 - Newmac 8010024G (WA0)

1200 100,000 1/2 HP Newmac 8010001 (WB100)

8010024G 8010001

Show 4 more labels / short text on this page
CFM Btuh Output · Blower · CFM Btuh Output · Blower

Ask about the Frigidaire KG7 Series

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire KG7 Series

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire KG7 Series manual PDF

16 pages·1.4 MB·Furnace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…