Fig. 1 · All about the

All about the

Installation

of your

Split Type Room Air Conditioner

Model(indoor/outdoor)FRS09PYW1/FRS09PYC1 FRS12PYW1/FRS12PYC1 FRS184YW2/FRS184YC2 FRS18PYW2/FRS18PYC2 FRS224YW2/FRS224YC2 FRS22PYW2/FRS22PYC2

a c. e ria digirf. w w w m o c. e ria digirf. w w w

7 6 5 1 - 2 4 9 - 6 6 8 - 1 a d a n a C 7 6 5 1 - 2 4 9 - 6 6 8 - 1 A S U

Page 2 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — 04 Safety precautions
Page 2 · click to enlarge
Page 2

Safety precautions

This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician.

1. Do not attempt to install the split air conditioner by yourself. 2. This air conditioner contains no user-serviceable parts. Always call

1. Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively. 2. Do not climb on or place objects on the outdoor unit. 3. Do not hang objects off the indoor unit. 4. Do not place containers containing water on the indoor and/or outdoor units. 5. Turn off the air conditioner at the power source when it will not be used for an extended period of time. 6. Periodically check the condition of the outdoor unit’s installation base for any damage. 7. Do not apply heavy pressure to the radiator fins of the indoor and/or outdoor units. 8. Operate the indoor unit with air filters in place. 9. Do not block or cover the intake grille, discharge area and outlet

an authorized Electrolux servicer for repairs. 3. When moving the air conditioner, always call an authorized Electrolux

servicer for disconnection and re-installation. 4. Do not insert or place fingers or objects into the air discharge area in the front of the indoor unit. 5. Do not insert or place fingers or objects into the air discharge area in the outdoor unit. 6. Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box. 7. Do not cut or damage the power cord. 8. If the power cord is damaged it should only be replaced by an authorized Electrolux servicer. 9. In the event of a malfunction (sparks, burning smell, etc.) immediately stop the operation, disconnect the power

ports. 10.Ensure that any electrical/electronic equipment is one yard away from the indoor unit and outdoor unit. 11.Do not use or store flammable gases near the indoor and/or

cord, and call an authorized Electrolux servicer. 10.Do not operate the air conditioners with wet hands 11.Do not pull on the power cord. 12.Do not drink any water that is drained from the air conditioners.

outdoor units.

04 Safety precautions

or Death

Page 3 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — 05 Safety precautions
Page 3 · click to enlarge
Page 3

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.

1. Connect with the power properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
Frigidaire Air Conditioner (FRS09PYC1) — 05 Safety precautions diagram (page 3)
Fig. 2 · 05 Safety precautions
2. Always ensure effective grounding. No grounding may cause electric

shock.

3. Disconnect the power if strange

sounds, smell, or smoke comes from it. It may cause fire and electric shock.

4. Do not operate or stop the unit by

switching on or off the power. It may cause electric shock or fire due to heat generation.

Frigidaire Air Conditioner (FRS09PYC1) — 05 Safety precautions diagram (page 3)
Fig. 3 · 05 Safety precautions
5. Do not operate with wet hands or in

damp environment. It may cause electric shock.

6. Do not allow water to run into

electric parts. It may cause failure of

machine, electric shock or fire.

7. Do not use the power cord near

9.Do not damage or use an

flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.

unspecified power cord. It may cause electric shock or fire.

10.Do not place heavy object on the

8. Do not use the power cord close to

power cord and ensure that the

heating appliances. It may cause fire and electric shock.

is danger of fire or electric shock. cord will not be compressed. There

05 Safety precautions

Page 4 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Safety precautions 06
Page 4 · click to enlarge
Page 4

11.Do not open the unit during

operation. It may cause electric

Frigidaire Air Conditioner (FRS09PYC1) — Safety precautions 06 diagram (page 4)
Fig. 4 · Safety precautions 06

shock or injury.

from air conditioner. It contains 12.Do not drink water drained

contaminants and could make you sick.

13.Do not disassemble or modify unit.

and electric shock. It may cause failure of appliance

14.When the air filter is to be

removed, do not touch the metal parts of the unit. It may cause an injury.

Frigidaire Air Conditioner (FRS09PYC1) — Safety precautions 06 diagram (page 4)
Fig. 5 · Safety precautions 06

15.When the unit is to be cleaned,

switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire, electric shock or injury.

16.Avoid direct exposure of occupants

to air flow.

17.Turn off the main power switch when

not using the unit for a long time.

18.The air conditioner may be dusted with an oil free cloth, or washed with a cloth dampened in a solution of warm water and mild dishwashing detergent. Rinse thoroughly and wipe dry. Wring excess water from cloth before wiping around controls.

20.Always insert the filters securely.

Clean filter once every two weeks.

cause failure. Operation without filters may

21.Always install circuit breaker and a

dedicated power circuit. No installation may cause fire and electric shock.

the outdoor unit will not damage 19.Ensure that the installation bracket of

due to prolonged exposure. If bracket damages, there will be

22.Do not place obstacles around air-

inlets or inside of air-outlet. It may cause failure of appliance or accident. concern of damage due to falling of unit.

Safety precautions 06

Page 5 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Choosing the installation site 06 07
Page 5 · click to enlarge
Page 5

Choosing the installation site

1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. 4. Pay attention to danger and safety notices

Installation at the following sites may cause problems. If you must inevitably install

the unit at one of these sites, please consult your local distributor beforehand: 1. Sites with machine oil.

2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.

Choosing the installation site 06 07

Installation Warnings · Precautions for Installation

Page 6 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Choosing the installation site 08
Page 6 · click to enlarge
Page 6
1. The unit must be installed at a site that does not obstruct the flow of air. 2. The site must support the weight of the indoor unit. 3. The site must be easily accessible for maintenance and replacement of the air filter. 4. The site must allow for the necessary space around the indoor

inside wall, always leaving a space of

at least 6" between the top of the

indoor unit and the ceiling.

8. The site must allow for the easy removal of the connector pipe and drain hose. 9. The unit must be installed at a site protected from direct sunlight.

unit, as shown in the sideward

figure.

meter) between the unit and radio 5. There should be at least 3 feet (1

Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 6)
Fig. 6 · Choosing the installation site 08
Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 6)
Fig. 7 · Choosing the installation site 08

or television devices. It is ideal

that the unit be installed at the

6. It must be far from fire, smoke or center.

flammable gases.

We recommend the indoor unit to be

installed as high up as possible on the

than 1.65' than 1'

1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated.
2. The site must support the weight of the outdoor unit and allow for vertical installation.
3. There must not be the possibility of increased noise and vibration at the site.

than 1.65' than 6.6'

4. The unit must be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or animals.
6. The site must provide enough

space around the unit, as shown

in the figure.

7. Children must not be able to
5. The site cannot have any leakage of flammable gases.

access the installation site.

Choosing the installation site 08

Show 13 more labels / short text on this page
Indoor Unit · More · than 6" · More · than 6" · More · than 6" · Outdoor Unit · More More · More · than 1' · More · More
Page 7 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Choosing the installation site 08
Page 7 · click to enlarge
Page 7
Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 7)
Fig. 8 · Choosing the installation site 08
Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 7)
Fig. 9 · Choosing the installation site 08
Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 7)
Fig. 10 · Choosing the installation site 08
Frigidaire Air Conditioner (FRS09PYC1) — Choosing the installation site 08 diagram (page 7)
Fig. 11 · Choosing the installation site 08
Page 8 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Parts list 10
Page 8 · click to enlarge
Page 8
Frigidaire Air Conditioner (FRS09PYC1) — Parts list 10 diagram (page 8)
Fig. 12 · Parts list 10
Frigidaire Air Conditioner (FRS09PYC1) — Parts list 10 diagram (page 8)
Fig. 13 · Parts list 10

Parts list 10

Page 9 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Indoor unit installation 11
Page 9 · click to enlarge
Page 9

Indoor unit installation

Installation plates and dimensions

6" or more from

Installation plate the ceiling

Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 9)
Fig. 14 · Indoor unit installation

(A:33.31" B:10.83")

Installation plate the ceiling 6" or more from

door unit outline 6" or more from the wall B erant pipe right) Ø 2.56" 7.91''A6" or m from th Refriger hole (rig 1.58'' 5.31'' 1.58''
Frigidaire Air Conditioner (FRS09PYC1) — (A:33.31" B:10.83") diagram (page 9)
Fig. 15

=18000 Btu's (A:36.97" B:11.73")

Indoor unit installation 11

12000 Btu's

Page 10 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Indoor unit installation
Page 10 · click to enlarge
Page 10

Installation plate the ceiling 6" or more from

Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 10)
Fig. 16 · Indoor unit installation

Refrigerant pipe hole (right) Ø 2.56"

3.94'' 4.88'' =21500 Btu's (A:39.69" B:12.40")

Fixing the Installation Plate

1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown
Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 10)
Fig. 17 · Indoor unit installation

Fit the Installation Plate and drill holes in the wall according to the wall structure and corresponding mounting points on the installation plate (Dimensions are in “mm” unless otherwise stated).

in the figures above.

2. In the case of tiled, concrete or

similar walls, create 0.2"

diameter holes. Place anchorage supports for the appropriate assembly screws. 3. Fix the installation plate to the

A type screws. wall with eight

4. At all times securing to the wall studs is recommended.
Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 10)
Fig. 18 · Indoor unit installation
1. Determine the position of the

hole for the pipes using the

installation plate and drill the

pipe hole so that it is tilted slightly

downward.

2. Always use a pipe cover with an

opening when drilling.

Indoor unit installation

Indoor unit outline · Installation plate · Drilling the Hole

Page 11 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Indoor unit installation
Page 11 · click to enlarge
Page 11

Connective pipe and drainage installation

Pipe cover (left) Pipe holder Pipe cover (right)

1. For the left-hand and right-hand piping, remove the pipe cover from
Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 11)
Fig. 19 · Indoor unit installation

the side panel. The pipe cover

must be kept as it may

be used the air

conditioner to any other place.

2. For the rear-right-hand and rear-lefthand piping, install the piping as

Connective pipe Indoor unit outline

shown in the sideward figure. Bend

Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 11)
Fig. 20 · Indoor unit installation

the connective pipe to be laid at

a height of 1.69" or less from

1.69"

the wall. Fix the end of the

connective pipe.

Frigidaire Air Conditioner (FRS09PYC1) — Indoor unit installation diagram (page 11)
Fig. 21 · Indoor unit installation

Do not block water flow by a rise.

1. Run the drain hose sloping downward. Do not install the drain

hose as illustrated sideward.

2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.

Do not put the end of drain hose into water.

Fastening the Indoor Unit

1. Pass the piping through the hole in the wall. 2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked.

Indoor unit installation

Show 7 more labels / short text on this page
Connective pipe · Left piping · when relocating · piping · Drainage · Upper hook · Lower hook
Page 12 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Indoor unit installation
Page 12 · click to enlarge
Page 12
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is hooked securely.

Piping and wrapping 1. Bundle the tubing, connecting cable, and drain hose with tape

securely and evenly as shown in the sideward figure.

2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is

Wrapping belt Drain hose

piped out of room, do not put

anything else in the box.

1. Connect the indoor unit first, then the outdoor unit. 2. Do not allow the piping to let out from the back of the indoor unit. 3. Be careful not to let the drain hose slack.
4. Both of the auxiliary piping should be heat insulation.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating

at the upper side may cause drain pan to overflow inside the unit.

6. Never intercross nor intertwist the power wire with any other wiring. 7. Run the drain hose sloped downward to drain out the condensed water smoothly.

Indoor unit installation

Show 7 more labels / short text on this page
Cushioning material · Ponding box · Indoor unit · Cable · Pipe room · connection · Connective pipe
Page 13 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Outdoor unit installation
Page 13 · click to enlarge
Page 13

Outdoor unit installation

1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles.
3. Install the unit at the site where it is exposed to as little wind as possible,

especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates.

5. Be sure there is no obstacle which

schrubs or bushes. blocks radiating air, including

Outdoor unit installation

Strong wind

Page 14 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — 16 Outdoor unit installation
Page 14 · click to enlarge
Page 14

Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid

% mount with a bolt and nut 0.39" or

0.32" diameter (Purchased separately).

A ft) B( ft) Outdoor unit dimension ft(WxHxD)

[ [ 1'

[ [

Condensate drainage of outdoor unit (no for cooling only)

The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:Insert the drain connection into one of the 25 holes of the chassis and then connect drainage pipe with drain nozzle. Insert drainage plugs into the other holes (Only for 12000Btu's).

Ø

12000 Btu's < •%WX V

Chassis Drain connection Drainage Plug

16 Outdoor unit installation

Show 12 more labels / short text on this page
$ · Air inlet · Air inlet · Air outlet · · · · [ [ · · ' · • · Chassis Drain connection
Page 15 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Refrigerant piping connection
Page 15 · click to enlarge
Page 15

Refrigerant piping connection

Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long,

loop for excess.

Flaring work Main cause for refrigerant leakage is due to defect in the flaring work.

Carry out correct flaring work using the following procedure:

1. Cut the pipes and the cable. A) Use the piping kit accessory or

pipes purchased locally. B) Measure the distance between the

indoor and the outdoor unit. C) Cut the pipes a little longer than the

measured distance. D) Cut the cable 4.9ft longer than the

pipe length. 2. Burr removal A) Completely remove all burrs from

the cut cross section of pipe/tube.

B) Put the end of the copper

tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.

3. Put nut on.

Cooper tube Remove flare nuts attached to

indoor and outdoor unit, then put them on pipe/tube having

completed burr removal.(It is not

possible to put them on after flaring work)

Refrigerant piping connection

Show 6 more labels / short text on this page
Pipe · Correct Wrong · Oblique Roughness Burr · Pipe · Reamer Point down · Flare nut
Page 16 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Refrigerant piping connection
Page 16 · click to enlarge
Page 16
4. Flaring work.
Frigidaire Air Conditioner (FRS09PYC1) — Refrigerant piping connection diagram (page 16)
Fig. 22 · Refrigerant piping connection

Firmly hold copper pipe in a

die in the dimension shown in the table below.

Frigidaire Air Conditioner (FRS09PYC1) — Refrigerant piping connection diagram (page 16)
Fig. 23 · Refrigerant piping connection

Connection Adjustment 1. Align the pipes to be connected.

2. Screw the flare nut with your fingers, and then tighten it with a spanner and torque wrench, as shown in the following figure.

Pipings Indoor unit tubing

Frigidaire Air Conditioner (FRS09PYC1) — Refrigerant piping connection diagram (page 16)
Fig. 24 · Refrigerant piping connection

Refrigerant piping connection

Show 5 more labels / short text on this page
Copper · Red arrow mark · Clamp handle · Flare · nut
Page 17 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — 208/230V-AC
Page 17 · click to enlarge
Page 17

Power voltage should meet the requirements in the following table. 3. Over current protection and circuit disconnect should meet the requirements in the following table and the applicable local and national electrical codes.

System Voltage Volts-Ph.-

n a F r o o d n I n a F r o o d t u O r o s s e r p m o C MIN. Circuit

Max. Fuse/Circuit

(BTU)

(Min/Max) RLA LRA FLA HP Output

Watts Volts FLA HP Output

(MCA)

9K 115-1-60 ǂ 103/127 16.03 26 0.17 0.04 30 115V-AC 0.38 0.03 20 22

12K 115-1-60 ǂ 103/127 17.53 26 0.17 0.04 30 115V-AC 0.38 0.03 20 23

18K 208/230-1-60 ǂ 187/253 11.54 41 0.62 0.08 60 208/230V-AC

0.25 0.03 20 16

21.5K 208/230-1-60 ǂ 187/253 11.71 41 0.9 0.12 90 0.45 0.05 35 16

208/230V-AC

Connecting (Power and Control Cable)

The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four

wires and provides the power for the indoor unit as well as the communication signal and ground between the outdoor and indoor unit.

Two wires are high voltage AC power, one is low voltage DC signal and one is a ground wire.

Consult local building codes, NEC (National Electrical Code) or CEC (Canadian Electrical Code) for special requirements.

Show 8 more labels / short text on this page
Electrical Data Table · Operating · Capacity · Voltage · Ampacity · Breaker Amps(MOCP) · Freq · Watts
Page 18 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Electrical work
Page 18 · click to enlarge
Page 18

Connect the cable to the indoor unit

1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type
Frigidaire Air Conditioner (FRS09PYC1) — N(1) 2 3 diagram (page 18)
Fig. 25
Frigidaire Air Conditioner (FRS09PYC1) — N(1) 2 3 diagram (page 18)
Fig. 26

designation 16AWG or heavier

cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoors respectively. 5. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any electrical components. Secure the cable onto the control board with the cord clamp.

Terminal block of indoor unit

N(1) 2 3

1.57" 0.39"

Electrical work

Show 4 more labels / short text on this page
cover Electrical box · Cable · Code wire · To Outdoor Unit
Page 19 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — N(1) 2 3
Page 19 · click to enlarge
Page 19
Frigidaire Air Conditioner (FRS09PYC1) — N(1) 2 3 diagram (page 19)
Fig. 27
Frigidaire Air Conditioner (FRS09PYC1) — N(1) 2 3 diagram (page 19)
Fig. 28
Page 20 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Electrical work and air purging
Page 20 · click to enlarge
Page 20

After the confirmation of the above conditions, prepare the wiring as follows:

1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
2. The screws which fasten the wiring in the casing of electrical fittings are

liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3. Specification of power source. 4. Confirm that electrical capacity is sufficient. 5. See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6. Confirm that the cable thickness is as specified in the power source specification. 7. Always install an earth leakage circuit breaker in a wet or moist area.

8. The following would be caused by voltage drop: vibration of a magnetic

switch, which will damage the contact point, fuse breaking, disturbance of

the normal function of the overload protector.

9. The means for disconnection from a power supply shall be incorporated

in the fixed wiring and have an air gap contact separation of at least 1/8 inch

in each active (phase) conductors.

Air purging

Air and moisture in the refrigeration system have undesirable effects as indicated

below: 1. Pressure in the system rises. 2. Operating current rises.

5. Water may lead to corrosion of parts in the refrigeration system.

Therefore, the indoor unit and tubing

3. Cooling or heating(only for models with heating function) efficiency drops.

between the indoor and outdoor unit

must apply leakage test and be evacuated to remove any noncondensables and

4. Moisture in the refrigerant circuit may freeze and block capillary tubing.

moisture from the system.

Electrical work and air purging

Page 21 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — A C
Page 21 · click to enlarge
Page 21

Air purging with vacuum pump

1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. When relocating the unit to another place, perform evacuation using vacuum pump. 3. Pipe length and refrigerant amount:

Additional amount of refrigerant to be charged Connective pipe length

Less than 25'

Use vacuum pump.

R410a0.32ozs/ft (Pipe length-25')

Use vacuum pump. 25'~65.6 ( 12000Btu's) < '

R410a0.22ozs/ft (Pipe length-25')

Use vacuum pump. 25'~98.4 '

R410a0.32ozs/ft (Pipe length-25')
1. Operation of opening packed valve: Open the valve stem until it hits against

the stopper. Do not try to open it further.

2. Operation of closing packed valve: Securely tighten the valve stem with a special tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to

for valve stem cap tightening torque tightening torque table in page 17

high side outlet. The low side outlet is shown in the sketch map below. Note: There is a charging port integrated in the low side outlet, but not in the

Indoor unit Outdoor unit

A C

D

B

Air purging

Show 13 more labels / short text on this page
Air purging · (=18000Btu's) · (=21500Btu's) · Flare nut · Refrigerant · Valve body · Gas · Cap · Charge port · Packed valve · Valve stem · Half union · Stopper
Page 22 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Air purging 24
Page 22 · click to enlarge
Page 22

When using the vacuum pump

For method of using a manifold valve, refer to its operation manual.

1. Completely tighten the flare nuts at connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect vacuum hose to valve core tool. Open the schrader valve. Note: The schrader valve is inside the charging port.
2. Connect the other charge hose of

manifold valve to the vacuum pump.

3. Fully open the handle Lo of the
Frigidaire Air Conditioner (FRS09PYC1) — Air purging 24 diagram (page 22)
Fig. 29 · Air purging 24

manifold valve.

4. Operate the vacuum pump to

evacuate. After starting evacuation, slightly loose the flare nut of the Lo valve on the gas pipe side and check if the air is entering (Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus), then tighten the flare nut. The procedure verifies if there are blocks inside the tubes.

Handle Lo Handle Hi

5. Make evacuation for 15 minutes or more and check that the compound meter indicates -7.6 x 10 MicronsHg (-1x10 Pa).

display in the pressure indicator is a little higher than the atmosphere pressure. This procedure verifies if the refrigerant goes through the tubes correctly.

After the evacuation is completed,

fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump.

7. Close the schrader valve, then remove the valve core tool.

Replace the charging port cap.

6. Turn the stem of the packed

packed valve. 9. Securely tighten the cap of the stems B and A. 8. Fully open the packed valve

valve B about 45 counterclockwise for 6~7

seconds after the gas comes

out, then tighten the flare nut again. Make sure the pressure

Air purging 24

Show 8 more labels / short text on this page
Indoor unit · Outdoor unit · Manifold valve · Charge hose · -76cm/Hg · Charge hose · Vacuum pump · o
Page 23 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Electrical safety and gas leak check
Page 23 · click to enlarge
Page 23

Electrical safety

Perform the electric safety check after completing installation:

1. Insulated resistance: The insulated resistance must be more than 2M . 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 . 3. Electrical leakage check (performing during test running): During test operation after finishing installation, the serviceman can use the electric probe and multimeter to perform the electrical leakage check. Turn off the unit immediately if electrical leakage happens. Check and find out the solution ways till the unit operates properly.

Gas leak check

Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping. If bubbles come out, the pipes have

indoor unit check point

leakage point.

Leak detector Use the leak detector to check for leakage.

Outdoor unit check point

Electrical safety and gas leak check

Cover

Page 24 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Test running
Page 24 · click to enlarge
Page 24

Test running

Perform test operation after completing gas leak check at the flare nut connections and electrical safety check.

1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on.

oF), the unit 3. When the ambient temperature is too low(lower than 63 function), AUTO and FAN to check if all the functions work well. 2. Use the MODE button to select COOL, HEAT(Only for models with heating

cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only when the remote controller is disable or maintenance necessary.

Frigidaire Air Conditioner (FRS09PYC1) — Test running diagram (page 24)
Fig. 30 · Test running
Frigidaire Air Conditioner (FRS09PYC1) — Test running diagram (page 24)
Fig. 31 · Test running
Frigidaire Air Conditioner (FRS09PYC1) — Test running diagram (page 24)
Fig. 32 · Test running
Frigidaire Air Conditioner (FRS09PYC1) — Test running diagram (page 24)
Fig. 33 · Test running
Frigidaire Air Conditioner (FRS09PYC1) — Test running diagram (page 24)
Fig. 34 · Test running

Test running

Auto/OFF · Manual control button

Page 25 of the Frigidaire Air Conditioner (FRS09PYC1) user manual — Preparing the device for operation
Page 25 · click to enlarge
Page 25

Preparing the device for operation

1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly. 4. If the unit has been out of use for a long period of time, it is recommended that the air filter be cleaned before use. During continuous use, clean the air filter every two weeks. 5. This air conditioner was designed for use under the following conditions:

MODE

Indoor Indoor Outdoor Indoor Outdoor

61°F~86°F 41°F~115°F 61°F~86°F 61°F~86°F 41°F~115°F 5°F~75°F

only for models with heating function

If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally.

excess of this figure, the surface of the air conditioner may attract condensation. Room relative humidity should be less than 80%. If the air conditioner operates in

Please set the horizontal louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

Optimum performance will be achieved within these operating temperature.

Preparing the device for operation

Show 6 more labels / short text on this page
Cool · Heat* · Dehumidifier · Temperature Temperature Temperature · Outdoor · *

Ask about the Frigidaire Air Conditioner (FRS09PYC1)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire Air Conditioner (FRS09PYC1)

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire Air Conditioner (FRS09PYC1) manual PDF

25 pages·1.4 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…