Installation Instructions Gas & Electric Dryer Instructions d’Installation Sécheuse à Gaz ou Électrique Instrucciones para la instalación Secadora a Gas y Eléctrica

1 www.frigidaire.com P/N 137101400 (0806)

Page 2 of the Frigidaire 137101400 user manual — DANGER
Page 2 · click to enlarge
Page 2

CONTENTS Pre-Installation Requirements 2 Electrical Requirements 3 Gas Supply Requirements 3 Exhaust System Requirements 3-5 Location of Your Dryer 5 Rough-In Dimensions 6 Unpacking 7 General Installation 7 Replacement Parts 7 Mobile Home Installation 8 Reversing Door Swing 8-10 Electrical Installation 11 Grounding Requirements 11 Gas Connection 11 Electrical Connections—3-wire 12 Electrical Connections—4-wire 12 Français 13-23 Español 24-34

SAFETY INSTRUCTIONS Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier. Install the clothes dryer according to the manufacturer's instructions and local codes. Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference. NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code C22.1 part 1. NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000

RISK OF FIRE. For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life. SAVE THESE INSTRUCTIONS. - Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS

· Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Clear the room, building or area of all occupants. · Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions. · If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Your safety and the safety of others is very important. We have provided many important safety messages in the Use & Care Guide, Operating Instructions, Installation Instructions and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you or others. All safety messages will be preceded by the safety alert symbol and the word "DANGER" or "WARNING". These words mean:

DANGER

You will be killed or seriously injured if you don't follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

PRE-INSTALLATION REQUIREMENTS Tools and Materials Required for Installation: 1. Phillips head screwdriver. 2. Channel-lock adjustable pliers. 3. Carpenter's level. 4. Flat or straight blade screwdriver. 5. Duct tape.

6. Rigid or flexible metal 4 inch (10.2 cm) duct. 7. Vent hood. 8. Pipe thread sealer (Gas). 9. Plastic knife.
Page 3 of the Frigidaire 137101400 user manual — GROUNDING PRONG
Page 3 · click to enlarge
Page 3

ELECTRICAL REQUIREMENTS

GAS SUPPLY REQUIREMENTS

ELECTRIC Dryer CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers.

Replace copper connecting pipe that is not plastic-coated. Stainless steel or plastic-coated brass MUST be used.

Use separately fused circuits for washers and dryers, and DO NOT operate a washer and a dryer on the same circuit.

1. Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition).

POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.

POWER SUPPLY CORD KIT - 3 wire - the dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp., with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. See ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.

2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass. 4. The gas supply line MUST have an individual shutoff valve.

4 wire - The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp., with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. See ELECTRICAL CONNECTIONS FOR A 4- WIRE SYSTEM. (Canada - 4-wire power supply cord is installed on dryer.)

5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.
6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).

WARNING – Risk of Shock. Appliance grounded to neutral conductor through a link. Grounding through the neutral link is prohibited for (1) New branch circuit installations (2) mobile homes; (3) recreational vehicles; and (4) areas where local codes do not permit grounding through the neutral, (1) disconnect the link from the neutral, (2) use grounding terminal or lead to ground appliance in accordance with local codes and (3) connect neutral terminal or lead to branch circuit neutral in usual manner (if the appliance is to be connected by means of a cord kit, use 4-conductor cord for this purpose). USE COPPER CONDUCTOR ONLY.

7. The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood and the ground or any other obstruction.

OUTLET RECEPTACLE - NEMA 10-30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position. (Canada - NEMA 14-30R receptacle.)

The following are specific requirements for proper and safe operation of your dryer. Failure to follow these instructions can create excessive drying times and fire hazards.

NEMA 10-30R NEMA 14-30R

CIRCUIT - Individual 15 amp. branch circuit fused with a 15 amp. maximum time delay fuse or circuit breaker.

Do not install a clothes dryer with flexible plastic venting materials. If your present system is made up of plastic duct or metal foil duct, replace it with a rigid or semi- rigid metal duct. In Canada and the United States if metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dry- ers and in the United States must also comply with the Outline for Clothes Dryer Transition Duct, UL standard 2158A. Flexible venting materials are known to collapse, be easily crushed and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire. Ensure the present duct is free of any lint prior to installing dryer duct.

POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz, Alternating Current.

POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3- wire power cord.

Frigidaire 137101400 — NEMA 10-30R NEMA 14-30R diagram (page 3)
Fig. 1

GROUNDING PRONG

GAS Dryer

Page 4 of the Frigidaire 137101400 user manual — CORRECT INCORRECT
Page 4 · click to enlarge
Page 4

Explosion hazard. Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.

MAXIMUM LENGTH of 4” (10.2 cm) Dia. Rigid Metal Duct

VENT HOOD TYPE (Preferred) Number

Louvered2½" (6.35 cm) 060 ft.(18.28 m)48 ft.(14.63 m) 152 ft.(15.84 m)40 ft.(12.19 m) 244 ft.(13.41 m)32 ft. (9.75 m) 332 ft.(9.75 m)24 ft. (7.31 m) 428 ft.(8.53 m)16 ft. (4.87 m) Numb of 90° TurnMAXIMUM LENGTH of 4” (10.2 cm) Dia. Flexible Metal Duct er VENT HOOD TYPE (Preferred) Louvered s 4” 2½" (10.2 cm) (6.35 cm) 030 ft. (9.14 m)18 ft. (5.49 m) 122 ft. (6.71 m)14 ft. (4.27 m) 214 ft. (4.27 m)10 ft. (3.05 m) 3NOT RECOMMENDED

- Risk of Fire - A clothes dryer must be ex- hausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area.

Frigidaire 137101400 — CORRECT INCORRECT diagram (page 4)
Fig. 2

CORRECT INCORRECT

INSTALL MALE FITTINGS IN CORRECT DIRECTION

In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:

Do not allow combustible materials (for ex- ample: clothing, draperies/curtains, paper) to come in con- tact with exhaust system. The dryer MUST NOT be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.

1. Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.

Exceeding the length of duct pipe or num- ber of elbows allowed in the "MAXIMUM LENGTH" charts can cause an accumulation of lint in the exhaust system. Plug- ging the system could create a fire hazard, as well as increase drying times.

2. Set the dryer timer and temperature to air fluff (cool down) and start the dryer.
3. Read the measurement on the manometer.

Do not screen the exhaust ends of the vent system, nor use any screws, rivets or other fastening means that extend into the duct and catch lint to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire haz- ard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.

4. The system back pressure MUST NOT be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer: • Only the rigid metal duct work should be used.

Page 5 of the Frigidaire 137101400 user manual — CLOSET DOOR
Page 5 · click to enlarge
Page 5
  • Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction.
  • Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint.

MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0 (0 cm) 0 (0 cm) Closet 0 (0 cm) 0 (0 cm) 1 (2.54 cm) Closet door ventilation required: 2 louvered openings each 60 square inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and top of door.

  • Compression or crimping of the exhaust system will cause an increase in vent restriction. The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.

This dryer MUST be exhausted outdoors.

5. The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation.

EXHAUST DIRECTION All dryers shipped from the factory are set up for rear exhausting. However, on electric dryers, exhausting can be to the right or left side of the cabinet or the bottom of the dryer. On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer. Directional exhausting can be accomplished by install- ing Exhaust Kit, P/N 131456800, available through your parts dis- tributor. Follow the instructions supplied with the kit.

60 sq. inches (387.1 sq. cm)

EXHAUST DUCT LOCATING DIMENSIONS

Frigidaire 137101400 — EXHAUST DUCT LOCATING DIMENSIONS diagram (page 5)
Fig. 3

SAME AS OTHER SIDE SAME AS OTHER SIDE SAME AS OTHER SIDE SAME AS OTHER SIDE SAME AS OTHER SIDE

60 sq. inches (387.1 sq. cm)

5 7/8" 5 7/8" 5 7/8" 5 7/8" 5 7/8"

4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8"

13 1/2" 13 1/2" 13 1/2" 13 1/2" 13 1/2"

3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4"

(9.5 cm) (9.5 cm) (9.5 cm) (9.5 cm) (9.5 cm)

LOCATION OF YOUR DRYER

CLOSET DOOR

DO NOT INSTALL YOUR DRYER: 1. In an area exposed to dripping water or outside weather conditions.

2. In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET 1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.

0" (0 cm) 1" (2.54 cm)

2. No other fuel burning appliance shall be installed in the same closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation. DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

0" (0 cm) · 0" (0 cm)

Page 6 of the Frigidaire 137101400 user manual — Stacked Dryer Installation Dimensions
Page 6 · click to enlarge
Page 6

Dryer Installation Dimensions

Free-Standing & Under Counter

Frigidaire 137101400 — Free-Standing & Under Counter diagram (page 6)
Fig. 4 · Free-Standing & Under Counter

Electrical supply on rear of unit (123.19cm)

Frigidaire 137101400 — Free-Standing & Under Counter diagram (page 6)
Fig. 5 · Free-Standing & Under Counter

5.0”

(12.7cm)

Center line height for rear, right, left vent 13.5”

4.375” To side exhausts To rear & base exhausts

5.875” To base exhaust

27.25 to front of cabinet 27.75 to clear knobs 28.5 to clear door handle

(69.22cm) (70.49cm)

(72.39cm)

Stacked Dryer Installation Dimensions

Frigidaire 137101400 — Stacked Dryer Installation Dimensions diagram (page 6)
Fig. 6 · Stacked Dryer Installation Dimensions

on rear of unit

28.25” to front of cabinet 28.75” to clear knobs 29.5” to clear door handle 49” to clear open door

41.00" 10440
Page 7 of the Frigidaire 137101400 user manual — PACKING
Page 7 · click to enlarge
Page 7

UNPACKING 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove the foam shipping base.

6. If your dryer does not operate, please review the "Avoid Service Checklist" located in your Use and Care Guide before calling for service.
7. Place these instructions in a location near the dryer for future reference. NOTE: A wiring diagram is located inside the dryer console or under the top panel.

To prevent damage, do not use the control panel as a means to pick up or move the dryer.

2. Return the dryer to an upright position.
8. To stack your dryer on a compatible washer, visit web site www.frigidaire.com, call your local dealer or call the Toll Free number (1800 - 444 - 4944) to find your local distributor to purchase stacking kit accessory part number STACKIT2 .
Frigidaire 137101400 — REPLACEMENT PARTS diagram (page 7)
Fig. 7

REPLACEMENT PARTS

Pedestal A pedestal accessory, Model No. NLPWD15 (White), NLPWD15GB (Glacier Blue), NLPWD15P (Platinum) and NLPWD15E (Black), specifically designed for this dryer may be used when elevating the dryer for ease of use. Failure to use accessories certified by the manufacturer could result in personal injury, property damage or damage to the dryer.

PACKING

GENERAL INSTALLATION

If replacements parts are needed for your dryer, contact the source where you purchased your dryer, call 1-800-944-9044, or visit our website, www.frigidaire.com for the Frigidaire Company Authorized Parts Distributor nearest you.

1. Connect the exhaust duct to outside exhaust system (see pages 3 and 4). Use duct tape to seal all joints.
2. With the dryer in its final position, adjust one or more of the legs until the dryer is resting solid on all four legs. Place a level on top of the dryer. The dryer MUST be level and resting solid on all four legs.

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

3. Plug the power cord into a grounded outlet. NOTE: Check to ensure the power is off at circuit breaker/fuse box before plugging the power cord into the outlet.

Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a garbage container or make materials inaccessible to children.

4. Turn on the power at the circuit breaker/fuse box.

The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and maintaining any appliance.

Before operating the dryer, make sure the dryer area is clear and free from combustible materials, gasoline, and other flammable vapors. Also see that noth- ing (such as boxes, clothing, etc.) obstructs the flow of combustion and ventilation air.

5. Run the dryer through a cycle check for proper operation.

NOTE: On gas dryers, before the burner will light, it is neces- sary for the gas line to be bled of air. If the burner does not light within 45 seconds the first time the dryer is turned on, the safety switch will shut the burner off. If this happens, turn the timer to "OFF" and wait 5 minutes before making another attempt to light.

6. If your dryer does not operate, please review the "Avoid Service Checklist" located in your Use and Care Guide before calling for service.
Page 8 of the Frigidaire 137101400 user manual — REMOVE 4 SCREWS (ONE FROM EACH HINGE FIRST)
Page 8 · click to enlarge
Page 8

MOBILE HOME INSTALLATION

REVERSING DOOR SWING

Solid Door Reversing Instructions: 1. Open door and remove four (4) plugs in the door opening opposite the hinges. Retain all parts for uses later, un- less otherwise noted. Note: Use care in removing plugs in not scratching paint on the front panel.

1. Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred.
Frigidaire 137101400 — MOBILE HOME INSTALLATION diagram (page 8)
Fig. 8
Frigidaire 137101400 — MOBILE HOME INSTALLATION diagram (page 8)
Fig. 9
Frigidaire 137101400 — MOBILE HOME INSTALLATION diagram (page 8)
Fig. 10
2. If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.
3. When installing a gas dryer into a mobile home, a provision must be made for outside make up air. This provision is to be not less than twice the area of the dryer exhaust outlet.
Frigidaire 137101400 — MOBILE HOME INSTALLATION diagram (page 8)
Fig. 11
4. This dryer MUST be fastened to the floor. Mobile Home Installation Kit No. 346764 is available from your dealer.

REMOVE 4 SCREWS (ONE FROM EACH HINGE FIRST)

5. Refer to pages 2 and 3 for other important venting requirements.
2. Begin removing the four (4) screws that attach the hinge to the front panel. For best results, start by only removing one screw per hinge. Then only loosen the two remaining screws while firmly holding door to prevent damage to hinge, front panel or door. After the remaining screws are loosened, continue to remove all.
6. Installation MUST conform to current Manufactured Home Construction & Safety Standard (which is a Federal Regulation Title 24 CFR-Part 32-80) or when such standard is not applicable, with American National Standard for Mobile Homes.

The dryer is designed under ANSI Z 21.5.1 or ANSI/ UL2158 - CAN/CSA C22.2 (latest editions) for HOME USE only.

3. Place door handle side down on a towel or pad to prevent any possible scratches to door. Remove all remaining four (4) screws between hinge and door.
4. Remove four (4) screws on opposite side of door.
5. Separate inner door from outer door by placing a flat screw driver or putty knife. Rotate the inner door 180 degree and reassemble the two door halves.
6. Install four (4) screws securing door halves where hinge was previously attached.
7. Install four (4) screws securing hinge to door assembly.
8. Remove striker and discard.
9. Remove square plug and reinstall in hole striker was just removed.

10.Install striker (included in literature bag) into hole square plug was previously installed.

11.Grasping firmly the top of the door, position the door near the door opening and align the top hinge hole to the top hole in the front panel door opening. Once the first screw is started, attach the second screw to the lower hinge. Once both screws are tightened, install the remaining two screws.

Page 9 of the Frigidaire 137101400 user manual — Window Door Reversal Instructions
Page 9 · click to enlarge
Page 9

Window Door Reversal Instructions

Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 12 · Window Door Reversal Instructions
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 13 · Window Door Reversal Instructions

Figure 1 1.Open door and remove four (4) plugs in the door opening opposite the hinges. Retain all parts for uses later, unless otherwise noted. (Figure 1) Note: Use care in removing plugs in not scratching paint on the front panel.

Figure 4 5. Remove two (2) door handle screws and two (2) hole plugs from door. Again taking care not to scratch paint on door. (Figure 4)

Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 14 · Window Door Reversal Instructions
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 15 · Window Door Reversal Instructions

Figure 2 2. Begin removing the four (4) screws that attach the hinge to the front panel. (Figure 2) For best results, start by only removing one screw per hinge. Then only loosen the two remaining screws while firmly holding door to prevent damage to hinge, front panel or door. After the remaining screws are loosened, continue to remove all.

Figure 5 6. Pull handle away from door assembley. (Figure 5)

Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 16 · Window Door Reversal Instructions
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 9)
Fig. 17 · Window Door Reversal Instructions

Figure 6 7. Separate the outer door from the inner door assembly with a putty knife or flat screw driver. (Figure 6)

Figure 3 3. Place door on a towel or pad handle side down to prevent any possible scratches to door. Remove all remaining four (4) screws between hinge and door. (Figure 3) 4. Remove four (4) screws from side of door opposite of where hinge was mounted.

Page 10 of the Frigidaire 137101400 user manual — Window Door Reversal Instructions
Page 10 · click to enlarge
Page 10
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 18 · Window Door Reversal Instructions
11. Reassemble lens to transition ring with holes to install handle on right-hand side of door assembly. For proper fit insure the retention tabs on transition ring are on top of lens
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 19 · Window Door Reversal Instructions

Figure 7 8. Remove lens locating screw. (Figure 7)

Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 20 · Window Door Reversal Instructions

Figure 11 12. Reassembly outer door to inner door assembly. (Figure 11) 13. Install four (4) screws securing hinge to door assembly in the new location, take note to place hinge in correct orientation. 14. Install four (4) screws into holes that had secured the hinge. 15. Remove striker and discard. 16. Remove square plug and reinstall in hole striker was just removed. 17. Install striker (included in literature bag) into hole square plug was previously installed.

Figure 8 9. Disengaging several of the retention tabs and pull lens away from the transition ring. (Figure 8)

Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 21 · Window Door Reversal Instructions
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 22 · Window Door Reversal Instructions
Frigidaire 137101400 — Window Door Reversal Instructions diagram (page 10)
Fig. 23 · Window Door Reversal Instructions

Figure 12 18. Reinstall door handle by placing the handle mounting bosses through holes in lens and transition ring and installing screws through inner door and tighten into handle bosses. (Figure 12). 19. Grasping firmly the top of the door, position the door near the door opening and align the top hinge hole to the top hole in the front panel door opening. Once the first screw is started, attach the second screw to the lower hinge. Once both screws are tightened, install the remaining two screws. 20. Install four (4) plugs into the front panel door opening where hinges were originally installed.

Figure 10 10. Remove two (2) transition ring plugs and reinstall on previous handle side. (Figures 9 and 10)

Page 11 of the Frigidaire 137101400 user manual — VALVE OPEN / GAS FLOW POSITION
Page 11 · click to enlarge
Page 11

ELECTRICAL INSTALLATION

The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/ or a fire hazard.

For a grounded, cord-connected dryer:

1. The dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.

This appliance MUST be properly grounded. Electrical shock can result if the dryer is not properly grounded. Follow the instructions in this manual for proper grounding.

2. Since your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. Do not modify plug provided with the appliance.

Do not use an extension cord with this dryer. Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt, creating electrical shock and/or fire hazard. Locate the dryer within reach of the receptacle for the length power cord to be purchased, allowing some slack in the cord. Refer to the pre-installation requirements in this manual for the proper power cord to be purchased.

A U.L. approved strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.

1. The dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug.

Do not use an aluminum wired receptacle with a copper wired power cord and plug (or vice versa). A chemical reaction occurs between copper and aluminum and can cause electrical shorts. The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle. NOTE: Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply.

GAS CONNECTION

1. Remove the shipping cap from gas pipe at the rear of the dryer.

GROUNDING REQUIREMENTS

2.Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer (see pages 6 and 7). Use a 1/2 inch to 3/ 8 inch (1.27 cm to 0.96 cm) reducer for a connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections. 3. Open the shutoff valve in the gas supply line to allow gas to flow through pipe.

Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.

For a grounded, cord-connected dryer:

4. Test all connections by brushing on a soapy water solution.
1. The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.

NEVER test for gas leaks with an open flame.

2. If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. Do not modify plug provided with the appliance.

For a permanently connected dryer: 1. The dryer MUST be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

VALVE OPEN / GAS FLOW POSITION

Show 4 more labels / short text on this page
Canadian ELECTRIC Dryer · ELECTRIC Dryer · ALL GAS Dryers · USA ELECTRIC Dryer
Page 12 of the Frigidaire 137101400 user manual — RED
Page 12 · click to enlarge
Page 12

ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM

FOR 3-WIRE SYSTEM

1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.
1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.
2. Install a U.L. approved strain relief in the entry hole of the mounting bracket. Finger tighten the nut only at this time.
2. Install a U.L. approved strain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time.
3. Remove the ground wire from the green ground screw located above the terminal block.

GREEN GROUND SCREW

Frigidaire 137101400 — GREEN GROUND SCREW diagram (page 12)
Fig. 24

SILVER TERMINAL

G GREEN ROUNDGROUND WIRESILVER TERMINAL CREWTERMINAL BLOCK
Frigidaire 137101400 — SILVER TERMINAL diagram (page 12)
Fig. 25

NEUTRAL GROUND WIRE

NUT

TIGHTEN NUT TO THESE THREADS

TIGHTEN NUT TO THESE THREADS

NEUTRAL GROUND

BLACK

WHITE

NUT

RED

STRAIN

RELIEF MOUNTING

STRAIN RELIEF MOUNTING BRACKET

POWER CORD

POWER CORD

3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief.
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or SRDT through the strain relief.
4. Attach the power cord neutral (center wire) conductor to the silver colored center terminal on the terminal block. Tighten the screw securely.
Frigidaire 137101400 — NEUTRAL GROUND WIRE diagram (page 12)
Fig. 26

TYPICAL 4 CONDUCTOR TYPICAL 4 CONDUCTOR

BLACK

WHITE

5. Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block. Tighten both screws securely.

RED

GREEN 30 AMP NEMA 14-30 TYPE SRDT OR ST

5. Attach the green power cord ground wire to the cabinet with the green ground screw.

Do not make a sharp bend or crimp wiring/ conductor at connections.

6. Attach the white (neutral) power cord conductor from the power cord and the neutral ground wire from the dryer harness to the silver-colored center terminal on the terminal block.
6. Reattach the strain relief mounting bracket to the back of the dryer with two screws. Tighten screws securely.

Tighten the screw securely.

7. Tighten the screws securing the cord restraint firmly against the power cord.
7. Attach the red and black power cord conductors to the outer brass-colored terminals on the terminal block.
8. Tighten the strain relief nut securely so that the strain relief does not turn.

Do not make a sharp bend or crimp wiring/ conductor at the connections.

9. Reinstall the terminal block cover.
8. Tighten the screws securing the cord restraint firmly against the power cord.
9. Tighten the strain relief nut securely so the strain relief does not turn.

10.Reinstall the terminal block access cover.

USA ELECTRIC Dryer · USA ELECTRIC Dryer

Ask about the Frigidaire 137101400

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire 137101400

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire 137101400 manual PDF

35 pages·2.4 MB·Clothes Dryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…