GENERAL SAFETY RULES
2. Electrical Safety a) Double Insulated tools are equipped with a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in any way. Double Insulation eliminates the need for the three wire grounded power cord and grounded power supply system. b) Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded. c) Do not expose power tools to rain. Do not use power tools in damp or wet locations. Water entering a power tool will increase the risk of electric shock. d) Do not abuse the cord. Never carry the tool by the cord or yank the cord to pull the plug from a receptacle. Keep cord away from heat, oil, sharp edges, or moving parts. Replace damaged cords immediately. Damaged cords increase the risk of electric shock. e) When operating a power tool outside, use an outdoor extension cord marked "W-A" or "W". These cords are rated for outdoor use and reduce the risk of electric shock.
3. Personal Safety a) Stay alert, watch what you are doing and use common sense when operating a power tool. Do not operate a tool while you are tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury. b) Dress properly. Do not wear loose clothing or jewelry. Wear protective hair covering to contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. Rubber gloves and non-skid footwear are recommended when working outdoors. c) Avoid unintentional starting. Be sure switch is off before plugging in. Do not carry tools with your finger on the switch or plug in tools that have the switch turned on. d) Form the habit of checking to see that keys and adjusting wrenches are removed from the tool before turning it on. A wrench or a key that is left attached to a rotating part of the tool may result in personal injury. e) Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the tool in any situation. f) Use safety equipment. Always wear protective glasses. Also use a face or dust mask if cutting operation is dusty.

4. Tool Use and Care a) Secure your work. Use clamps or a vise to secure and support the work piece to a stable platform. Securing the work with a clamp or vise frees both hands to operate the tool. Holding the work by hand or against your body is unstable and may lead to loss of control. b) Do not force tool. The power tool will do the job better and safer at the rate for which it was intended. c) Use the correct tool for your application. Do not use tools for purposes for which they were not intended. d) Do not use tool if switch does not turn it on or off. Any tool that cannot be controlled with the switch is dangerous and must be repaired. Have defective switches replaced by an authorized Freud service center. e) Disconnect the plug from the power source when not in use, before servicing, and when changing accessories such as blades, bits, and cutters. Such preventive safety measures reduce the risk of starting the tool accidentally and causing personal injury. f) Store idle tools when not in use. Tools should be stored in a dry, high, or locked-up place and out of the reach of children. g) Maintain tools with care. Keep cutting tools sharp and clean for better and safer performance. Follow instructions for lubricating and changing accessories. Inspect tool cords periodically and, if damaged, have repaired by and authorized Freud service center. Inspect extension cords regularly and replace if damaged. Keep handles dry, clean, and free from oil or grease. Properly maintained tools, with sharp cutting edges are less likely to bind and are easier to control. h) Check for damaged parts. Before further use of the tool, a guard or other part that is damaged should be carefully inspected to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, mounting, and other conditions that may affect the operation of the tool. A guard or other part that is damaged should be properly repaired or replaced by an authorized Freud service center unless otherwise indicated elsewhere in this instruction manual. i) Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used with another tool.
5. Service a) Tool service must be performed only by an Freud authorized service center. Service or maintenance performed by unqualified personnel could result in a risk of injury. b) When servicing a tool, use only identical replacement parts. Follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury. Certain cleaning agents such as gasoline, carbon tetrachloride, ammonia, etc. may damage plastic parts.

To ensure safer operation of this tool, Freud has adopted a double insulation design. "Double Insulation" means that two physically separated insulation systems have been used to insulate the electrically conductive materials connected to the power supply from the outer frame handled by the operator.

A - Depth Adjustment Knob B - Variable Speed Control C - Micro Adjustment Knob D - Turret Stop Rod E - Side Handles
F - Coarse Adjustment Knob G - Arrow Indicator H - Turret Stop Rod Locking Screw I - Depth Stop Turret
J - Spindle K - Spindle Lock (Shaft Lock)


D
E
F
G
M

H

N
J
O
L - Above Table Height Adjustment Access M - Depth Adjustment Wrench N - Collet & Collet Nut O - On/Off Trigger Switch P - Plunge Locking Lever Q - 22mm Collet Nut Wrench R - Above Table Spindle Lock Access


*Router bits over 1-1/2” diameter should be used only with the router mounted in a router table. The router base plate must be removed to to accept bits larger 21/2” diameter. Consult the router table’s user manual for maximum bit diameter that can be used in the router table
Some of the following symbols may be used on your tool. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the tool better and safer.

INSTALLING AND REMOVING THE ROUTER BIT (2 Options)
a) Insert the Depth Adjustment Wrench (M) into the Height Adjustment Access (L) and turn counter clockwise until the collet and collet nut (N) extend fully through the base.– Fig 1 (It may be necessary to rotate the Depth Stop Turret to the flat surface without any stops (see area marked with “X”- Fig. 11) to allow the collet to fully extend through the base.) b) Insert the Depth Adjustment Wrench (M) into the Above Table Spindle Lock Access (R) and rotate clockwise until it stops turning. Rotate Spindle (J) until the Spindle Lock (K) pin engages. When the Spindle Lock pin is correctly engaged, you will not be able to rotate the spindle. – Fig 2 c) Using the included 22mm Collet Nut Wrench (Q), turn the collet nut counter clockwise to loosen the collet. If a bit is already in the collet the collet nut will loosen for approximately 1 turn and then become tight again. Continue turning the nut counter clockwise with the wrench until the nut is loose again. At this point the bit should be released and easy to remove from the collet– Fig 3 d) Insert the router bit and rotate the collet nut with the 22mm wrench clockwise to tighten the collet. Always be sure that at least 80% of the router bit shank is inserted in the collet but never allow the bit shank to “bottom out” in the collet. – Fig 4 e) Insert the Depth Adjustment Wrench (M) into the Above Table Spindle Lock Access (R) and rotate counter clockwise until it stops turning. – Fig 5a f) Turn the height adjustment knob clockwise until the router bit returns fully inside the base. – Fig 5b g) Before operating the router, follow directions in the section in this manual titled "Adjusting Depth of Cut" to properly set the depth of cut. h) To remove a router bit from the collet, follow steps a, b, and c and then remove the router bit.
(Option 1)







Router bits over 1-1/2" diameter should be used only with the router mounted in a router table.








a) Release the plunge lock lever (P) and turn the depth adjustment knob (A) counter clockwise to raise the router motor to its highest position. – Fig. 6 b) Next, position the router on its side or stand it upside down on its cap before continuing. c) While pressing the spindle lock button (K), rotate the spindle (J) until the spindle lock pin engages the spindle. When the spindle lock pin engages, you will not be able to turn the spindle. d) While pressing the spindle lock button, use the 22 mm wrench to rotate the collet (N) counter clockwise to loosen the collet. If a bit is already in the collet the collet nut will loosen for approximately 1 turn and then become tight again. Continue turning the nut counter clockwise with the wrench until the nut is loose again. At this point the bit should be released and easy to remove from the collet – Fig. 7 e) Insert the router bit inside the collet making sure that at least 80% of the router bit shank is inside the collet but never allow the bit shank to “bottom out” in the collet. f) While pressing the spindle lock button (H), rotate the spindle (J) until the spindle lock pin engages the spindle. Using the 22 mm wrench, turn the collet clockwise until the collet is tight. – Fig. 8 g) Before operating the router, follow the directions in the section of this manual titled "Adjusting Depth of Cut" to properly set your depth of cut. h) To remove a router bit, follow steps a, b, c, and d and then remove the router bit.


(Option 2)

Adjusting Depth of Cut

There are two methods for adjusting the depth of cut on the FT3000 Router. The Depth Adjustment Knob (A) is best for non plunging operations. The Depth Stop Turret (I) and Turret Stop Rod (D) is best for operations where there are repeatable depth settings or two or more depth settings may be needed.
1) Depth Adjustment Knob: –Fig 9. When Plunge Locking Lever (P) is released, the Depth Adjustment Knob (A) may be used to raise and lower the router motor. Turn the knob clockwise to increase the depth of cut and counter-clockwise to reduce the depth of cut. Once the desired depth of cut is reached, push up on the Plunge Locking Lever (P) to lock the setting. Always be sure that the Plunge Locking Lever (P) has been released and the Turret Stop Rod (D) cannot hit a stop on the Turret (I) before using the Depth Adjustment Knob (A). If router is mounted in a router table, insert the Depth Adjustment Wrench (M) into the Above Table Height Adjustment Access (L) to raise and lower the router motor. Turn the wrench counter-clockwise to increase the depth of cut and clockwise to reduce the depth of cut.
P
A

Note: The Depth Adjustment Wrench (M) can be inserted into the Depth Adjustment Knob (A) and used to adjust the depth of cut. 2) Depth Stop Turret and Turret Stop Rod: –Fig 10. The Depth Stop Turret (I) and Turret Stop Rod (D) allow you to preset up to three cut depths. For maximum plunge action, the Depth Adjustment Knob (A) must be turned counter-clockwise until the motor is at the top of the rods. For fine adjustment of the cutting depth, there are three stops attached to the Depth Stop Turret (I) on the Base of the FT3000. The Depth Stop Turret turns so that each of the three stops can be positioned under the Turret Stop Rod (D). The Turret Stop Rod (D) has a Course Adjustment Knob (F) that raises or lowers the Turret Stop Rod to make large

adjustments quickly. The icro Adjustment knob (C) allows for fine adjustment of the Turret Stop Rod. You can set three different depths of cut for the same bit using the Turret and stops –Fig 11. Adjust the height of the three stop screws as necessary so that the difference in height is equal to the amount of material to be removed with each cut.

3) Setting the Router to Zero Plunge Depth: Rotate the turret (I) so that stop 3 is directly under the Turret stop Rod – Fig 12. Loosen turret stop rod locking screw (H) and raise turret stop rod (D) to its highest position using the course Adjustment Knob (F) – Fig 13. Release plunge locking lever (P) and gently plunge the router motor until the router bit barely touches the work surface. Lock the plunge locking lever – Fig 14. Rotate the coarse adjustment knob (F) to move the turret rod downward until it contacts stop 3. Raise the Turret Stop Rod until the arrow indicator is aligned with the closest large increment on the scale (i.e., 1⁄4", 1⁄2", 3⁄4", 1", etc.) – Fig 15. Turn the micro adjustment knob (C) until the turret stop rod contacts the stop screw. Tighten the stop rod locking screw – Fig 16. Your router is now set to zero plunge depth. Release the plunge locking level to allow the router’s motor to return to its maximum height. To adjust the router to your required cutting depth, rotate the coarse Adjustment screw to raise the Turret Stop Rod until the measurement on the scale is equal to the amount required for your final depth of cut.


H



Adjust Turret Rod to nearest scale number as shown below.





WARNING! Disconnect tool from power source. For template routing the Freud FT3000 accepts standard template guides which are available separately. To use template guides an optional adapter ring (Freud FT1100) must be attached to the base plate using the two slotted screws provided. Remove the slotted screws from the base plate, insert the adapter ring with the flat side toward the router body. Install and tighten the screws to secure the adapter ring. - Fig. 17

The base plate has been centered at the factory, however, if the base plate has been removed and remounted some adjustment may be necessary to center the template guides to the router bit. To adjust, loosen the four base plate screws that secure the base plate to the router, reposition the base plate and tighten the screws.
1. Powering the Tool On and Off a) Plug in the tool with the Trigger Switch in the OFF position and the lock button released. b) Hold the router firmly by both handles with the bit away from you and positioned so that the bit is not in contact with the wood or any part of your body or clothing. c) Start the tool by depressing the Trigger Switch. - Fig 18 d) Lock the tool in the run position by depressing the Locking Button with your thumb while the Trigger Switch is on. Release the Locking Button by momentarily depressing the Trigger Switch and releasing. e) Turn off the tool by releasing the Trigger Switch.

OFF


The Freud FT3000 is equipped with an electronic variable speed control feature.

This speed control has an infinite number of speeds from 8,000 to 21,000 RPM. The speed is adjusted by turning the speed control knob (B)- Fig 19. Consult the router bit manufacturer for recommended bit speed.
The electronic speed control keeps constant speed at all levels. If the motor speed decreases in use you may be exceeding the load capacity of the tool. This could cause damage to the motor by overheating. Reducing the depth of cut so that more passes are required and/or slowing the rate of feed will reduce the power requirements on the router.
FT3000 Router Speed Dial Settings RPM 21,000 18,000 16,000 13,000 10,000 8,000 0 1 2 3 4 5 6 Dial Settings
Bit Diameter Max RPM 1" 24,000 1-1/4" 18,000 2-1/4" 16,000 3-1/2" 12,000


1) Edge Cutting - Fig. 20 & Fig. 21 Consider the material that you are cutting and the amount of material that will be removed before using the tool. Make sample cuts on scrap wood before cutting the actual work piece. The router bit rotates in a clockwise direction when viewed from the top of the router. On external edge treatments move the router counter clockwise from left to right. For internal cutting move the router clockwise from right to left.
2) Plunge Cutting-Fig. 9 & Fig. 10 To make a plunge cut, grasp the router by both handles (E), position the router over the area to be routed, turn the power on, release the Plunge Locking Lever (P) and push down on the Router Handles (E). When the Turret Stop Rod (D) contacts stop 1 on the Depth Stop Turret (I), tighten the Plunge Locking Lever (P), and begin routing. Always allow the router to reach full speed before you begin the plunge. After the first cut is complete, release the Plunge Locking Lever (P), allow the Router Motor to return to the top of the rods, TURN THE POWER OFF AND WAIT FOR THE BIT TO COME TO A COMPLETE STOP, and move the Turret to stop 2, Repeat the plunge operation as you did for the first cut. The third cut is completed using the same steps with stop 3.

The Freud FT3000 can also be mounted to a router table. To mount the router, please follow the instruction included with the router table. The FT3000 includes a pattern for drilling the mounting screw holes and for drilling the Above Table Height Adjustment Access hole.

Service It is recommended that all service on your Freud tool be performed by an Authorized Freud service center. Service by unauthorized service personnel may result in misplaced internal components resulting in risk of tool malfunction and personal injury to the tool user.
Power Cord Check that the power cord is in good condition. If it is not, have it replaced immediately at a Freud Authorized service center.
Tool Lubrication All power tools require care and attention. Every couple of years, we recommend leaving the tool with an authorized Freud service center for a general cleaning and lubrication.
Ventilation Openings Make sure the air vents are always kept clean and free of obstacles. If clogged, vacuum out obstruction. It is recommended that you blow off the entire tool with compressed air after each use.
Bearings We recommend that at every couple of years, or when needed, the bearings be inspected by an authorized Freud service technician. Bearings that become very noisy should be replaced at once to avoid overheating or motor failure.
Inspect Accessories Regularly inspect your router bits. Using worn accessories with diminish the efficiency of the work and could damage the tool's motor.
Inspect Screws Regularly inspect all screws in your power tool and make sure they are properly tightened. Loose screws should be retightened immediately.

To locate a Freud Authorized Service Center near you, call: 1-800-334-4107 or visit our web site at: www.freudtools.com
In Canada call: 1-800-263-7016 or visit the Canadian site for a full list of service centers at: www.freud.ca

90 DAY MONEY BACK GUARANTEE If within the first 90 days from the date of original purchase you are not completely satisfied with your Freud power tool for any reason you may return the tool (in its original packaging and complete with all accessories) to the place of purchase with proof of purchase (e.g. dated sales receipt) for a full refund.
FREUD LIMITED FIVE YEAR POWER TOOL WARRANTY Freud warrants to the original consumer purchaser that each new Freud power tool shall be free from defects in material and workmanship for a period of five (5) years from the purchase date. When warranty service is requested, proof of purchase (e.g. dated sales receipt) is required. Should the power tool fail within ninety (90) days from the date of purchase, it will be repaired or replaced AT THE CUSTOMER'S OPTION subject to the guidelines below. Thereafter, upon verification of failure or malfunction, at Freud's option, Freud will repair or replace the power tool, subject to the guidelines below. This warranty does not cover damage incurred from repair or attempted repair by anyone other than Freud's authorized personnel, normal wear and tear, abuse, lack of maintenance, or accidents.
FREUD WARRANTY GUIDELINES 1. In the event of failure or malfunction, return the product, properly packaged and postage prepaid, to Freud at the address listed below or to an authorized Freud service station. For technical advice, instructions on returns, or a list of authorized repair stations, please contact us at (U.S.) 1-800-334-4107 (Canada) 1-800-263-7016. 2. All implied warranties for Freud power tools (INCLUDING MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE) are limited to the period of five (5) years from the purchase date by the original consumer purchaser. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. 3. A warranty claim shall be limited to repair or replacement as stated in Freud's Limited Power Tool Warranty, and in no event shall Freud be liable for any other direct, indirect, incidental or consequential damages, costs or expenses. INCIDENTAL AND CONSEQUENTIAL DAMAGES ARE EXCLUDED UNDER ALL WARRANTIES. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 4. Freud's warranties give you specific legal rights, and you may also have other rights which vary from State to State. 5. Freud's warranties shall not be deemed to have failed their essential purpose while Freud is willing to repair or replace defective products. 6. Freud assumes no liability for defects or damage caused by abuse or misuse of any product or unauthorized service of any product. The product must have been used for its recommended purpose and not modified or changed. Normal wear and tear is not covered under Freud's warranties. 7. Any legal action for breach of warranty must be commenced within one year after the claim has arisen. 8. All warranties are expressly limited to the original consumer purchaser. All warranties and other rights of the purchaser shall be governed under the laws of the State of North Carolina without regard to conflict of law principles.
To obtain service under Freud Limited Power Tool Warranty, contact an authorized repair station or:
(c) Copyright 2006, Freud America, Inc. All rights reserved.


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.