PORTABLE AIR CONDITIONER


For best results, and more enjoyment from your new FREECOM portable air conditioning unit, please read this instruction manual carefully and save for future reference.
Models RCS-S3000T RCS-S5000U · ® · 3000-398


Model Power/Electrical Cooling Capacity Input EER Requirements
RCS-S3000T 110/115 volt, 60Hz 12,500 BTU/h (3,630W) 1100W 11.4 RCS-S5000U 230 Volt, 50Hz 15,000 BTU/h (4,360W) 1,380W 10.9 RCS-S5000B 220 Volt, 50Hz 15,000 BTU/h (4,360W) 1,380W 10.9 HARDWARE (INCLUDED)
F.


A.
B.
G.
D.
H.
E.
A. Wall Bracket (2) B. 1/4" (6mm) screws and anchors (4) C. Set screws (2) D. Support belt with hook (2) E. Open-ended wrench
F. Remote control (1) G. "AAA" batteries (2) H. Dust Caps (2 sets)
(1 each—24 mm and 21 mm)

PLEASE READ AND FOLLOW ALL SAFETY INFORMATION AND INSTRUCTIONS BEFORE OPERATING YOUR NEW FREECOM AIR CONDITIONER.

D F
B


A
FRONT VIEW
G
Q
B
P


N
K
A. Indoor Unit B. Outdoor Unit C. Control Panel D. Horizontal Air Louver E. Air Outlet F. Built-in Handle G. Air Filter H. Emergency Water Drain Tube I. Water Drain Plug J. Power Cord K. Flex Tube L. Caster Wheels M. Connector Cover N. Fan O. Drain Port (outdoor unit) P. Support Plate Q. Interlocking Fastener (for securing outdoor unit onto indoor unit)
H
REAR VIEW



7 8 9 10 11

near open flame or heat source.










Indoor Unit

The outdoor unit can be either surface placed or wall-mounted. In either case, the out- door unit must be fitted so the flexible tube set easily reaches the indoor unit. The flexi- ble tube set can be routed through a window, door, or wall. For routing through a wall, please consult a certified contractor to perform interior and exterior hole cutting and dis- connecting the tube set.

There are two choices for installing the outdoor unit: surface placement and wall-mounting. See below for surface placing the outdoor unit. To wall-mount outdoor unit, please continue with "Wall-Mounting" for mounting instructions.
Surface Placement:
Wall-Mounting:




Outdoor Unit

Wall-Mounting (contd.)




This air conditioner is equipped with convenient quick Connect Couplings which allow for the removal and routing of the Tube Set through narrow windows or walls.
qualified heating and air conditioning professional.
Instructions for the removal and re-connecting of the Tube Set are available to qualified trade professionals by separate request to a Freecom Dealer.
IMPORTANT NOTICE: High pressure refrigerant gas and lubricants are present in the Tube Set. Improper removal of the Quick Connect Couplings could result in personal injury from exposure to high-pressure refrigerant materials. Improper connection of the Tube Set could result in refrigerant leaks. Leaking or loss of refrigerant materials will result in poor cooling performance and eventual damage to the motor compressor.
may produce toxic fumes.
Disconnecting Tube Set

upright positions for a minimum of two hours before operating. DO NOT operate unit without air filter properly in place or while tube set is disconnected.
This unit is intended to cool a 300-600 square foot area. The unit’s cooling capacity will vary according to room temperature and humidity. Consult your Freecom dealer for specific application and suitability.
“SPECIFICATIONS” on page 3.
appliances or electrical devices. When installing the electrical plug into the outlet, never touch or bend the metal prongs and always push plug into outlet by using the molded plug. Never use the electrical plug to start or stop the unit and avoid pulling, folding, or stretching the electrical cord.
DO NOT manually adjust the louvers.
Cooling

If you wish to check the timer setting after the timer has been programmed, press the "TIMER-SET" button on control panel while timer "ON" or "OFF" light is on. The display will show the hours remaining until the timer function is operating. Pressing "TIMER- SET" again will increase timer setting.
To Turn Unit On with Timer


If you wish to check the timer, press the "TIMER-SET" button on control panel while timer "ON" light is on. The display will show the hours remain- ing until the timer function is operating. Pressing "TIMER-SET" again will increase timer setting.
To Turn Unit Off with Timer
Wireless Remote Control Operation
The Wireless Remote Control has the same control buttons as are on the Control Panel. All functions operate the same as described under "CONTROL PANEL." The remote requires two "AAA" size batteries (included).


Operating the Timer

When the condensate water tank is full, the “DRAIN WATER” indicator light will flash, the unit will sound several initial warning beeps, and the unit will automatically turn off.
Draining Water Tank

This unit has one air filter. For best results and maximum performance, clean filter every two weeks, or as required by environmental conditions.
poor efficiency, reduced performance, possible damage to the unit, and voiding your warranty.








Repair due to improper filter installation is not covered under warranty.
properly installed.
Cleaning Air Filter



INDOOR UNIT 1. Press power on/off "I/O" button if unit is operating. Unplug power cord from outlet. 2. Drain water tube. See "Draining Water Tank" on page 13 for detailed instructions. 3. For long-term storage, turn the unit on to "FAN" mode and allow the unit to run for 3-4 hours. This will dry the inside of the unit. 4. Carefully wrap power cord and secure with cord wrap on back of unit. 5. Store unit in its UPRIGHT POSITION in a cool, dry indoor location. If possible, store unit in its original box. DO NOT store unit in direct sunlight.
OUTDOOR UNIT 1. Unplug power cord (on indoor unit) from outlet. 2. Carefully remove outdoor unit from mounting brackets and/or hooks. 3. Slowly tilt the outdoor unit to drain water from the drain port. 4. Clean cabinet surface of outdoor unit (see "Cleaning Cabinet Exterior" above). 5. Carefully lift the outdoor unit and align the support plates on the outdoor unit with the interlocking fasteners on the indoor unit. Carefully hang the outdoor unit onto the back of the indoor unit. 6. Cover the two connected units with a large, plastic bag. 7. Store two connected units in a cool, dry place. Do not store in direct sunlight.
Cleaning Cabinet Exterior

Before contacting a dealer or qualified service technician, please read and check the following troubleshooting guide. If, after reviewing and performing the following solu- tions, your unit should continue to operate improperly, turn unit off and contact your Freecom dealer for service.
SOLUTION
Unit does not turn on.
1. Make sure city power supply is normal. 2. Check plug is correctly installed into outlet. 3. Check fuses and household breaker switches. 4. Remove electrical plug from outlet. Check electrical cord and plug for damage. 5. Water tank is full. Check "DRAIN WATER" light. If it is on, drain water tank. See "MAINTENANCE AND CLEANING". 6. Compressor delay feature may be active. Unplug unit and wait for 3-5 minutes. Plug unit into outlet and press "POWER ON/OFF" switch. 7. Check/replace roller in cabinet. Please consult a qualified service technician for service.
Unit running low air flow or cooling.
Compressor stops after a short time.
Unit noisy when operating.
Water leaking from unit.