Instruction/ maintenance manual of the product Elettra.5F.STD Foster
Go to page of 37
Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com USER'S MANUAL FOR GAS COOKER HOBS Ab stra c t cod.
20 ENGLISH T able of Contents 1. Usage warnings ................................................................................................................... 21 2. Safety warnings .................................................................
21 ENGLISH GENERAL WARNINGS 1. Usage warnings This manual is and integral part of this appliance. It is necessary to keep it undamaged and on hand for the entire life cycle of the hob. We recommend carefully reading this document and all instructions contained within before using the appliance .
22 ENGLISH GENERAL WARNINGS 2. Safety warnings In your interest and for your safety , by law it has been established that instal - lation and service for all electric or gas appliances must be carried out by qualified personnel, according to current regulations and the require - ments of local companies supplying gas and electric power .
23 ENGLISH GENERAL WARNINGS disposed of correctly . Contact your reseller or competent organizations in your area for information about waste collection centres, recycling and disposal. DO NOT ABBANDON THE P ACKAGING MA TERIAL OR PAR TS OF IT . THEY MA Y CREA TE A SUFFOCA TION DANGER FOR CHILDREN, ESPECIALL Y PLASTIC BAGS.
24 ENGLISH INST ALLER INSTRUCTIONS ENGLISH 5. First installation Do not leave packaging material waste unguarded in the household environment. Separate the various packaging waste materials and deliver them to the closest selective waste collection centres.
25 ENGLISH INST ALLER INSTRUCTIONS • The distance of the cooker hob from the back edge must be at least 50mm; • The distance of the cooker hob from the walls that exceed worktop height mu.
26 ENGLISH INST ALLER INSTRUCTIONS • Accurately clean milling. • Before positioning the top, lay the sealer gasket provided on the entire milling surface [ Fig. 5 ]. • Once these operations have been completed, use the supplied brackets to fasten the hob to the structure.
27 ENGLISH INST ALLER INSTRUCTIONS 7.1 Fixed hooks They make it possible to fasten the cooker hob using fixing frames pre-set along specific points. Standard edge (8 mm) Q4 edge (4 mm) Semi-flush e.
28 ENGLISH INST ALLER INSTRUCTIONS Set hook B in frame A welded to the hob, making sure that it is blocked in the spe - cific holes based on top thickness (for a 30 mm thick top, lock the hook in the the highest hole in the frame; for a 40 mm thick top, block the hook in the lowest hole of the frame).
29 ENGLISH INST ALLER INSTRUCTIONS 7.3 Fixed brackets Make it possible to fasten the cooker hob in pre-set fastening points. Standard edge (8 mm) A B Introduce the bracket B in appropriate top seat.
30 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : Always place the gasket between the hob fitting and the connection pipe. • If using a stainless steel flexible pipe , it must be installed so that it does not come in contact with any part of the cabinet, but passes through an unoccupied area where its entire length can be inspected.
31 ENGLISH INST ALLER INSTRUCTIONS 10. Discharging combustion products (exhaust) Discharge of combustion products must be ensured through hoods connected to an efficient natural draught flue, or through a forced exhaust.
32 ENGLISH INST ALLER INSTRUCTIONS Gas type Burner Nominal power (KW) Rated con- sumption (g/h) Injector (ø mm) Min. nominal power (KW) Series No. Ref. METHANE GAS G20 20 mbar II 2 Auxiliary 1,00 95 0,72 0,52 3 Semi-quick 1,75 167 0,97 0,52 4 Quick 2,70 257 1,08 0,90 5 T riple crown 3,50 333 1,35 1,80 10 Dual 4,50 429 i 0.
33 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : After adjusting for use with a gas that is different from the initial testing one, replace the label on appliance housing with the one that corresponds to the new gas type. 12. Adjustment of the minimum Instructions for urban and methane gas 1.
34 ENGLISH USER INSTRUCTIONS It is mandatory to have an earth connection as per modes foreseen in the electrical system safety standards. • For direct connection to the electric mains, a device m.
35 ENGLISH USER INSTRUCTIONS The upper cover (B) of the burners must be placed in opposite seat with the two intro - ductions notches in correspondence of the two cylinders below (C) and tighten clock - wise. The associated burner is indicated near each knob.
36 ENGLISH USER INSTRUCTIONS 14.2 Practical recommendations for burner use For better burner yield, and minimum gas consumption, it is necessary to use flat and regular bottom pots, equipped with a cover and proportioned to the burner , in order to avoid that the flame goes up their sides (see the “Pots diameter” paragraph [ Page 36 ]).
37 ENGLISH USER INSTRUCTIONS 15. Cleaning and maintenance Do not use a steam jet to clean the appliance. Before any intervention it is necessar y to disengage the appliance power supply . Avoid leaving acid or alkaline (vinegar , lemon juice, salt, tomato juice,.
182 Riepilogo piani cottura a gas Legenda Serie N. Bruciatore Potenza (W) 1 Manopola di comando II 2 Ausiliario 1.000 3 Semirapido 1.750 4 Rapido 2.700 5 T ripla corona 3.500 10 Dual 4.500 III 6 Ausiliario 1.100 7 Semirapido 1.750 8 Rapido 3.000 9 T ripla corona 3.
187 1.1 4000 1 6 7 7 8 9 9 N7272V A = 1160 mm B = 480 mm N7272V 1200 1221 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 +1 0 1 6 7 7 8 9 N7252V A = 860 mm B = 480 mm N7252V 900 921 +1 0 500 521 R10.5 10.5 1.5 +1 0 +1 0 +1 0 1 7 7 6 8 9 N7270V A = 860 mm B = 480 mm N7270V 900 921 +1 0 500 521 R10.
188 1 8 6 7 7 8 7 N7253V A = 830 mm B = 480 mm N7253V 830 851 +1 0 500 521 +1 0 R10.5 10.5 1.5 +1 0 +1 0 6 7 7 8 1 N7251V A = 560mm B = 480 mm N7251V 600 +1 0 621 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 1 6 9 7 8 N7254V A = 1159 mm B = 348 mm N7254V 1180 +1 0 369 +1 0 1162 351 9 1.
189 1 14 N7278V-AEO A = 430 mm B = 480 mm 1 10 N7277V A = 430 mm B = 480 mm 1 12 11 N7276V-AEO A = 360 mm B = 480 mm.
190 1.2 QUADRA 1 2 5 3 4 N7215V A = 1162 mm B = 351 mm N7214V 1180 +1 0 369 +1 0 1162 351 +1 0 9 1.5 R10.5 +1 0 1 2 5 3 N7211V A = 862 mm B = 351 mm N7211V 369 +1 0 351 +1 0 R10.5 9 1.5 926 +1 0 908 +1 0 1 3 N7221V A = 309 mm B = 454 mm N7221V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.
191 1 5 N7223V A = 309 mm B = 454 mm N7223V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.5 1 1 2 5 2 4 3 N7238V 351 +1 0 955.5 +1 0 157.8 +1 0 45° 955.
192 1.3 KE 1 6 6 7 7 9 N7603VKE A = 840 mm B = 480 mm N7600VKE 7 1.5 500 +1 0 514 +1 0 790 +1 0 804 +1 0 R10.5 N7600VKE N7600VKE A = 770 mm B = 480 mm 1.
193 1.5 PROFESSIONALE 1 2 3 3 4 5 N7055V-10 N7055V-10 A = 840 mm B = 480 mm N7055V-10 7 1.5 500 514 R10.5 860 874 +1 0 +1 0 +1 0 +1 0 1 2 3 5 N7053V-10 A = 560 mm B = 480 mm N7053V-10 500 514 R10.
194 1 5 N7061V-08 A = 270 mm B = 480 mm 1.6 LISA 1 5 8 7 7 6 N7290V 828.8 587 506.8 R93.5 200.5 303 R161 R1262.5 N7290V 828.8 842.8 +1 0 587 +1 0 601 +1 0 506.
195 1.7 F AUST 1 2 3 3 3 5 N7075V N7048V A = 770 mm B = 480 mm N7047VFT1 7 1.5 500 514 +1 0 790 804 R10.5 +1 0 +1 0 +1 0 1.8 ELEONORA 1 2 3 3 3 5 N7095V A = 770 mm B = 480 mm N7295V 770 480 R135 N7296VFT R152 R145 7 1.
196 1.9 VULCANO 1 3 10 10 N7097V A = 950 mm B = 480 mm N7297V R152 R145 7 1.5 500 514 +1 0 970 984 +1 0 +1 0 +1 0 1.10 VERONIKA 1 2 4 5 3 3 N7067V A = 560 mm B = 480 mm 1 4 3 3 2 N7066V A = 560 mm B =.
197 1 8 7 6 N7063V A = 420 mm B = 480 mm 1 6 7 7 8 8 N7367V 500 +1 0 514 +1 0 760 774 +1 0 R152 R145 7 1.5 +1 0 1 1 6 8 7 7 N7266V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145.
198 1.11 ELETTRA - P ANDORA 1 2 4 5 3 3 N7064V A = 560 mm B = 480 mm 1 2 4 5 3 3 N7065V A = 560 mm B = 480 mm 1.12 MAGIC 1 2 3 3 4 N7024V A = 740 mm B = 480 mm N7044V 500 +1 0 514 +1 0 760 +1 0 774 +1 0 R152 R145 7 1.
199 1 4 5 3 N7021V A = 740 mm B = 480 mm 1 2 4 3 3 N7023V A = 560 mm B = 480 mm N7042V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145 1.13 ALIEN 1 3 5 4 N7017V A A = 840 mm B = 480 mm.
200 1.14 ANGOLARE 1 2 3 5 3 3 N7038V 619 810 330 480 20x45° 810 191x45° 619 810 +4 0 480 +4 0 +4 0 +4 0 +4 0 1.15 F2000 1 2 3 5 N7053000V A = 560 mm B = 480 mm 1 2 3 3 4 5 N7055000V A = 840 mm B = 4.
201 1.16 RONDÒ - GIOTTO 1 4 2 3 N7052V Ø 500 mm 1 10 N7051VG Ø 500 mm 1.17 ALF A 1 6 7 5 8 7 N7260V N7260V A = 840 mm B = 480 mm N7260V 7 1.5 500 +1 0 514 +1 0 R10.
202 1.18 GK 14 12 12 11 1 1 GK4F A = 1030 mm B = 450 mm GK4F 1030 +1 0 1051 +1 0 450 +1 0 471 +1 0 R10.5 10.5 1.5.
Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com cod. 9606801 Rev .
An important point after buying a device Foster Elettra.5F.STD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Foster Elettra.5F.STD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Foster Elettra.5F.STD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Foster Elettra.5F.STD you will learn all the available features of the product, as well as information on its operation. The information that you get Foster Elettra.5F.STD will certainly help you make a decision on the purchase.
If you already are a holder of Foster Elettra.5F.STD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Foster Elettra.5F.STD.
However, one of the most important roles played by the user manual is to help in solving problems with Foster Elettra.5F.STD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Foster Elettra.5F.STD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center