Hearth by FMI PRODUCTS, LLC
UNVENTED (VENT-FREE) GAS FIREPLACE SYSTEM OWNER’S OPERATION AND INSTALLATION MANUAL

MODELS VSGF36NRC AND VSGF36PRC
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com


Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on heater.
Fireplace front and screen be come very hot when running fire place. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire place will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor- making agent is added to gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
Carefully supervise young children when they are in the room with fireplace. When us ing optional hand-held remote accessory, keep selector switch in OFF position to prevent chil dren from turning on burners with remote.
You must operate this fireplace with the fireplace screen and hood in place. Make sure fire place screen and hood are in place before running heater.
Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.
State of Massachusetts: The installa tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.
1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269 Note: Where listed vented decorative logs are re quired, thermostat operation is not permitted.

Rear Burner Top Louver Assembly


Figure 1 - Log Base Assembly
Figure 2 - Fireplace

OPERATION This vent-free fireplace is clean burning. It re quires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. When used without blower, fireplace requires no electricity making it ideal for emergency backup heat.
IGNITION SYSTEM This fireplace has an electronic ignitor to light heater fuel supply.
REMOTE CONTROL This fireplace is equipped with a thermostat remote control. Remote can also be used manually. Use this remote to control tempera ture and flame height.
SAFETY DEVICE This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys tem. ODS/pilot is a required feature for vent- free room heaters. ODS/pilot system shuts off fireplace if there is not enough fresh air.
Base Assembly · Bottom Louver Assembly

PLANNING Plan where you will install firebox. This will save time and money later when you install your firebox. Before installation, consider the following: 1. Where firebox will be located. Allow for wall and ceiling clearances (see Installa tion Clearances, page 10).

Figure 3 - Firebox Dimensions
Left Side View

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un usually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out
WARNING: This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on
openable windows and doors and c. caulking or sealants are applied to
Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep cold air out and warm air in. During heat ing months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap pliances need fresh air for proper combustion and ventilation. Exhaust fans, fireboxes, clothes dryers and fuel burning appliances draw air from house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 9. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow for Heater Location, page 8.
Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag gregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un confined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation. All spaces in homes fall into one of these three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 7 through 9 will help you classify your space and provide adequate ventilation.

Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can sup port (volume of space) x 20 = (Maxi mum Btu/Hr the space can support) Example: 3168 cu. ft. (volume of space) x 20 = 63,360 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/ Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace + Btu/Hr Total = Btu/Hr
space can support) 79,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup port. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 9. B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors, page 9. C. Install a lower Btu/Hr fireplace, if lower Btu/
Hr size makes room unconfined. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
40,000 39,000 79,000


Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of ceiling and one within 12" of floor on wall connecting two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 5 - Ventilation Air from Outdoors
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
Figure 4 - Ventilation Air from Inside
Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo stat-controlled power vent. Heated air entering the attic will activate the power vent.

CAUTION: This fireplace cre ates warm air currents. These currents move heat to wall sur faces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited, to tobacco smoke, aromatic candles, clean ing fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 6) A. Clearances from the side of the fireplace
cabinet to any combustible material and wall should follow diagram in Figure 6. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This com bustible material must be 4" from the side of the fireplace cabinet (see Figure 6). B. Clearances from top of firebox opening to
Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing ma terial can be placed directly against any exterior surface on the rear, sides or top of your fireplace, except where standoff spacers are integrally at tached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials. Use dimensions shown for rough openings to create easiest installation. See Built-In Firebox Installation, page 11. IMPORTANT: Vent-free heaters add moisture to air. Although this is beneficial, installing fireplace in rooms without enough ventila tion air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 7. IMPORTANT: Make sure fireplace is level. If fireplace is not level, log set will not work properly.
ceiling should not be less than 42". C. When firebox is installed on carpeting or
other combustible material, other than wood flooring, firebox should be installed on a metal or wood panel extending full width and depth of the enclosure. D. Clearances from bottom of firebox to floor
is 0". These fireboxes can be installed as freestand ing units against a wall with approved, optional cabinet mantels (see Accessories, page 31) or as a built-in unit. Clearances are the same for either installation method.
CHECK GAS TYPE Use correct gas type (natural or propane/ LP) for your fireplace. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
*Minimum 16" from Side Wall
Figure 6 - Minimum Clearance for
Example · * · Combustible to Wall

Continued Mantel Clearances for Built-In Installation If placing custom mantel above built-in firebox, you must meet minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7. These are mini mum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize heating of objects and materials placed on mantel.
BUILT-IN FIREBOX INSTALLATION Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes front of firebox flush with wall. Optional brass trim accessories are available (see Accessories, page 31). Brass trim will ex tend past sides of firebox approximately 1/2". This will cover rough edges of wall opening. If installing a mantel above firebox, you must follow clearances shown in Figure 6, page 10. Follow instructions below to install firebox in this manner. 1. Frame in rough opening. Firebox framing should be constructed of 2 x 4 lumber or heavier. Use dimensions in Table 1 and rough opening layout in Figure 8, page 12. Adjust framing so that firebox flushes with finished wall surface. If installing in a corner, use dimensions in Figures 8 and 9, page 12 for rough opening.
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projec- tions off of the facing material.
Mantel Shelf Note: Any portion of the mantel shelf must NOT extend beyond this profile.
6 3/4"
1 1/2"
Noncombustible Material May Project Off this Surface above the Firebox Hood
Supplied Firebox Hood Must Be Used at All Times
Figure 7 - Minimum Mantel Clearances for Built-In Installation

2. Install gas piping to firebox location. See Installing Gas Piping to Fireplace Location on page 13 and Connecting Fireplace to Gas Supply, page 15. IMPORTANT: If installing blower accessory (circulating models with louvers only), see Hard-Wiring Firebox, page 19. 3. Carefully set firebox in front of rough open ing with back of firebox inside wall open ing. IMPORTANT: If installing a perimeter trim kit, see instructions included with trim accessory. You must install shoulder screws from trim kit now. 4. Carefully insert firebox into rough opening. 5. Attach firebox to wall studs using nails or wood screws through holes in nailing flange (see Figure 10). 6. If using an optional perimeter trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim accessory for attaching trim. 7. Install and properly test gas log heater. Follow installation instructions included with the vent-free gas log heater that is being installed. IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing.
Rough Opening Dimensions for
Built-in Installation Front Width
41 1/2" 40 1/2" 20 3/4"
Width (Inside to Inside)
Figure 8 - Rough Opening for Installing

Figure 9 - Rough Opening for Installing

Nails or Wood Screws

Figure 10 - Attaching Firebox to Wall

This firebox may be installed using the corner or cabinet mantel with hearth base acces sories against a wall in your home. A trim kit is included with mantel accessories (see Accessories, page 31). 1. Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc tions are included with each accessory. 2. Install gas piping to firebox location. See Installing Gas Piping to Fireplace Location. You may have to cut a hole in the floor or wall to run gas line to firebox. Make sure to locate access hole so it is covered by mantel/base when installed. 3. Place hearth base against wall at installation location. Cut an access hole in hearth top to run flexible gas line to firebox (see Figure 11). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over. 4. Route flexible gas line through access hole in hearth base. 5. Center cabinet mantel on hearth base (see Figure 12). Make sure mantel is flush against wall. 6. Install trim kit furnished with mantel. See instruction sheet included with mantel. 7. Carefully insert firebox into cabinet mantel. Be careful not to scratch firebox, mantel, base, etc. when installing (see Figure 13).
Figure 12 - Center Mantel on Hearth Base
Figure 13 - Inserting Firebox Into Cabinet Mantel (Model May Vary From
Hearth Base Gas Line Access Hole
Rigid Pipe and Gas Shutoff Valve
Figure 11 - Placing Hearth Base


Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 15). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

Natural Gas From Gas Meter (5" W.C.** to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C.** to 14" W.C. Pressure)
Propane/LP Supply Tank External Regulator with Vent Pointing Down
* Purchase the optional shutoff valve from your dealer. ** Minimum inlet pressure for purpose of input adjustment.
Pointing Down


We recommend that you install a sediment trap in supply line as shown in Figure 15, page 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sedi ment trap is not installed or is installed wrong, fireplace may not run properly.

4. Attach flexible gas line to gas supply (see Figure 17). Check tightness of flexible gas line attached to gas regulator of fireplace (see Figure 17). 5. Check all gas connections for leaks. See Checking Gas Connections, page 16. 6. Replace log base assembly back into fireplace. Feed flexible gas line into fire place base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reat tach log base assembly to fireplace with screws removed in step 2.

Equipment Shutoff Valve Provided by Installer
To Fireplace Gas Regulator

Natural Gas To Gas Meter
Figure 17 - Attaching Flexible Gas Lines
Figure 16 - Removing Log Base
Together · Assembly From Fireplace

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 18). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from gas meter to equip ment shutoff valve for natural gas or pro pane/LP supply to equipment shutoff valve for propane/LP (see Figures 19 and 20). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 18 - Equipment Shutoff Valve

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace with its main gas valve (control valve) and equipment shut off valve from gas supply piping system. Pressures in excess of 1/2 psig will dam age fireplace regulator. 2. Cap off open end of gas pipe where equip ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect fireplace and equipment shutoff valve to gas supply. Check recon nected fittings for leaks.
Figure 19 - Checking Gas Joints for

Figure 20 - Checking Gas Joints for

PRESSURE TESTING FIREPLACE GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 18, page 16). 2. Open main gas valve located on or near gas meter for natural gas or open pro pane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas control valve (see Figures 19 or 20, page 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operation, page 20.) Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 21.

Figure 22 - Remote Display
Remote Receiver The remote receiver uses 4 AA batteries (not included). To install or replace batteries: 1. Open lower louver to gain access to re ceiver. 2. Remove screws from cover place. 3. Remove battery housing cover. 4. Install or replace batteries. 5. Replace battery housing cover. 6. Replace cover plate.


Hand-Held Remote Control The hand-held remote control uses 3 AAA batteries (not included). To install batteries: 1. Remove battery housing cover from back of hand-held remote (see Figure 21). 2. Install or replace batteries.

Figure 23 - Battery Install Remote
Figure 21 - Battery Install Hand-Held
Screws · Control Receiver · Remote Control

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place bottom log in center of the base assembly as shown in Figure 24. 2. Rest rear log in back corner sections of base assembly as shown in Figure 24. Make sure log is completely vertical and not leaning in toward burner where the flame will touch the log. 3. Position front right log against right side of grate prongs (see Figure 24). 4. Position front left log against left side of grate prongs (see Figure 24).
Pin on Front Left Log
Figure 25 - Installing Top Logs
Base Assembly Front Right Log
Figure 24 - Installing Bottom Logs

INSTALLING FIREPLACE HOOD AND SCREEN 1. Loosen screws inside top edge of firebox. Slide notches in hood over screws and tighten screws (see Figure 27). 2. Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 28).
The “Handy Box” with duplex outlet is pro vided in the firebox located in the lower right base area. 1. Remove screw holding duplex outlet cover to handy box. Remove duplex outlet. 2. Route electrical cable through strain relief and handy box (see Figure 26). Tighten screws on strain relief. 3. Connect electrical cable to duplex outlet. Match wire colors to those on duplex out let. Be sure to connect the ground wire. 4. Place duplex outlet back into handy box and secure with screws. Replace outlet cover.
Figure 27 - Hood Placement (Model May Vary From Illustration)
Figure 26 - Hard-Wiring Firebox
Figure 28 - Screen Placement (Model May Vary From Illustration)

A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around
4. Press in and turn control knob clockwise to the OFF position. 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 6. Press in and turn control knob counter clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 29). Note: You may be running this heater for the first time after hooking up to gas sup ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a quali fied service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Ignitor Button Blower Control Knob
P
O
T
F
F
O
O
N
LO
Figure 29 - Control Knob and Ignitor
Control Knob · Button Location

7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep ignitor button pressed in until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. 8. Keep control knob pressed in for 30 sec onds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and switch selector switch to the ON position to light burners (see Figure 30). When using in the ON position (without remote) burners will light on high. There is no adjustment to the flames without using remote. 11. To leave pilot lit and shut off burners only, turn control knob clockwise to the PILOT position, or use remote control manual OFF button, or set selector switch in the OFF position.
Pilot Burner Ignitor Electrode
Figure 31 - Pilot
Figure 32 - Pilot
TO APPLIANCE 1. Turn control knob clockwise to the OFF position. 2. Set selector switch in the OFF position. 3. Close equipment shutoff valve (see Figure 18, page 16).
PROCEDURE 1. Follow steps 1 through 6 under Lighting Instructions, page 20. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 sec onds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions.
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower center inside louver door. Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions.
PRG
Figure 30 - Remote Selector Switch in

OPERATING REMOTE CONTROL
After lighting pilot, let pilot flame burn for about one minute. Slide remote selector switch to REMOTE position. You can now turn burner on and off with remote. IMPORTANT: Do not leave selector switch in REMOTE or ON position when pilot is not lit. This will drain batteries. When any button is pushed on remote control, LCD display will glow blue. Blue glow will go off after several seconds if no action is being taken with remote.
For installing or replacing batteries in remote control or receiver, see Installing Batteries in Remote Control and Receiver on page 17. Low Battery - Hand-Held Remote Control When batteries in hand-held remote control are low, an icon will appear on display. Low Battery - Remote Receiver When batteries in receiver are low, no acoustic signal will be given when ON/OFF button is pressed. If batteries in receiver are low, fireplace can be switched on manually by moving remote selector switch to ON (see Figure 33).
ON/OFF Push ON/OFF button and burners will come on in high position (see Figure 35). An acoustic signal from the receiver confirms the command. Push ON/OFF button again and burners will turn off. A beep from receiver confirms the command.
Figure 33 - Low Battery Display FAHRENHEIT/CELSIUS INDICATOR You can set your hand-held remote control to display the temperature in either Fahrenheit or Celsius. With remote control off, press THERMOSTAT button and MODE button at the same time. This will toggle the display from °F to °C.
THERMOSTAT
MODE
Figure 35 - Hand-Held Remote Control
Figure 34 - Remote Control Display
LCD Display · UP/ DOWN Arrows · Fahrenheit to Celsius

Continued FLAME HEIGHT This function allows you to control height of flames through 5 levels (see Figure 36). Se lect manual flame height function by pressing MODE button until a flame is shown in lower left corner of display. Use UP/DOWN arrow button to set desired flame height (see Figure 35, page 22). A beep from receiver confirms the command.
To activate this function, press THERMOSTAT button until the word SMART appears to the right of temperature bulb graphic on display. Use UP/DOWN arrow button to set desired room temperature. The control system will cycle the fireplace on or off to maintain se lected temperature.
ON ON
MAX
Figure 38 - Smart Thermostat Setting
CHILD SAFETY LOCK-OUT This function lets you deactivate the remote control buttons. It is active when the lock icon is lit on the display. To activate, press MODE button and UP ar row button at the same time. To deactivate, press again.
Figure 36 - Remote Control Display of Flame Height Minimum and Maximum
ROOM THERMOSTAT The remote control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in the room. To activate, press THERMOSTAT button on remote control (see Figure 35, page 22). The word ON will appear to the right of temperature bulb graphic on display (see Figure 37). Use UP/DOWN arrow button to set desired room temperature. Control system will cycle fireplace on or off to maintain selected temperature.
Figure 39 - Child Safety Lock-Out
REPLACING HAND-HELD REMOTE CONTROL ONLY If your remote ever needs to be replaced you will not need to replace the receiver. To program receiver with a new hand-held remote, insert a small pin or paper clip into hole on receiver face plate marked PRG. The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter. Press the ON/OFF button on your remote and the receiver will beep 4 times to confirm it receives commands from the new remote.
Figure 37 - Room Temperature Setting
SMART THERMOSTAT The Smart Thermostat adjusts flame height in accordance to differences between set temperature and room temperature. As room temperature gets closer to set temperature the smart function will modulate the flame lower. As room temperature cools, it will modulate the flame higher.
PRG
Figure 40 - Programing Remote Control

Check pilot flame pattern and burner flame patterns often.
(Pilot May Vary From Ones Shown)
Figure 43 - Correct Burner Flame Pattern
Yellow Tipping At Top of Blue Flame
Figure 41 - Correct Pilot Flame Pattern
Figure 42 - Incorrect
MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame pres ent. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes may create soot.
Figure 44 - Incorrect Burner Flame

4. Check injector holder located at end of burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into primary air holes on injector holder. 6. In case any large clumps of dust have now been pushed into burner repeat steps 3 and 4. Clean pilot assembly also. A yellow tip on pilot flame indicates dust and dirt in pilot assembly. There is a small pilot air inlet hole about two inches from where pilot flame comes out of pilot assembly (see Figure 46). With unit off, lightly blow air through air inlet hole. You may blow through a drinking straw if compressed air is not available.
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air in let holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could dam age the pilot assembly. 1. Shut off unit, including pilot. Allow unit to cool for at least thirty minutes. 2. Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 45). 3. Blow air through the ports/slots and holes in burner.
Primary Air Inlet Holes
Figure 45 - Injector Holder On Outlet
Pilot Air Inlet Hole
Figure 46 - Pilot Inlet Air Hole

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, there is no spark at ODS/ pilot.

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame goes out when control knob is released.
Delayed ignition of one or both burners.

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Slight smoke or odor during initial operation.
Moisture/condensation no ticed on windows.
Remote does not function. 1. Battery is not installed. Bat tery power is low.

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace produces unwanted odors.
control valve and burner. 2. Gas leak. See Warning statement at top of page.

TECHNICAL SERVICE You may have further questions about installa tion, operation or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling, please have your model and serial numbers of your firebox ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.
WIRING DIAGRAM Note: For proper operation of remote control, wires from thermopile to control receiver must be connected exactly as shown.
Figure 47 - Remote Control Wiring Diagram

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537 for referral information. A list of authorized dealers can be found by visiting www.fmiproducts.com
Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back page of this manual.
PERIMETER TRIM PT36 - Black PT36B - Brushed Brass PT36P - Platinum
FIREPLACE HANDLES - FPH 2 handles per kit.
FIREBOX BRICK LINER - HFL401 All Models. Ceramic fiber firebox liner adds the look of real brick. Aged red color panels with black mortar and straight brick pattern.
MANTELS W36TO - Cabinet Mantel & Base, Stained Oak, Traditional Design W36TU - Cabinet Mantel & Base, Unfin ished, Traditional Design C36TO - Corner Mantel & Base, Stained Oak, Traditional Design C36TU - Corner Mantel & Base, Unfinished, Traditional Design



PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.
VSGF36NRC



MODELS VSGF36PRC AND VSGF36NRC This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.
KEY NO. PART NO. DESCRIPTION QTY. 1 113190-01CK Screen 2 2 116865-01CK Bottom Louver Assembly 1 3 ** Face Weldment 1 4 101355-03CK Hood 1 5 116864-01CK Louver Assembly 1 6 ** Firebox Bottom Bracket 1 7 ** Right Firebox Support Leg 1 8 ** Left Firebox Support Leg 2 9 ** Firebox Surround 1 10 ** Firebox Top Shield 1 11 ** Firebox Top 1 12 ** Damper Can Collar 1 13 ** Insulation Pan 1 14 ** Fireplace Top Insulation 1 15 ** Fireplace Top 1 16 20280 Top Spacer 4 17 ** Fireplace Surround 1 18 107128-01 Gas Conduit 2 19 115408-01 Receptacle Plate 1 20 21171 Gas Knock-Out Cover 4 21 103771-01 Strain Relief 1 22 115402-01 Steel Receptacle Box 1 23 119943-01 Blower 1 24 M11084-38 Hex Screw, #8 3 25 GA3555 Duplex Outlet 1 26 115403-01 Steel Receptacle Cover 1 27 101378-01 Thermostat Switch 1 28 117539-01 Brick Refractory Kit 1 29 117891-01 FPH Handle Bracket 4 ** Not a field replaceable part.

Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
1-866-328-4537 www.fmiproducts.com
121082-01 Rev. K 01/11