B-VENT DECORATIVE GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL

models P324E, VP324E, P325E(B) AND VP325E(B)
FOR YOUR SAFETY — Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
Natural Gas

SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed. Keep it with your other important papers.
This appliance may be installed in an aftermarket*, per manently located, manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indi cated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
TABLE OF CONTENTS Safety 3 Unpacking 4 Introduction 4 Selecting Location 5 Product Specifications 6 Pre-Installation Preparation 7 Venting Installation 8 Fireplace Installation 11 Operation 18 Inspecting Burners 19
Cleaning and Maintenance 20 Replacement Parts 20 Service Hints 20 Technical Service 20 Wiring Diagram 21 Troubleshooting 22 Accessories 25 Parts 26 Warranty Back Cover

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ ence of alcohol and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire place nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70. 15. Do not install fireplace directly on carpet ing, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 16. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 17. Do not operate fireplace if any log is broken. 18. Provide adequate clearances around air openings.
These fireplace models are vented gas fire places that use an electronic ignition system. Models P325E/VP325E have a 5" B-vent and P324E/VP324EA have a 4" B-vent. A properly sized B-type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on page 9.
This FMI PRODUCTS, LLC appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by FMI PROD UCTS, LLC. Unless you use FMI PRODUCTS, LLC approved components tested for this appli ance, YOU MAY CAUSE A FIRE HAZARD! The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions : A) Modification of the appliance or any of the
components. B) Use of any component part not approved
by FMI PRODUCTS, LLC in combination with this appliance. C) Installation and/or operation in a manner
These models are factory equipped for use with natural gas and must be converted when intended for use with proper propane/LP gas. Conversion kits PCBE-324 and PCBE-325 may be purchased for simple conversion to propane/LP gas. See Accessories, page 25.
other than instructed in this manual. D) The burning of anything other than the
type of gas approved for use in this gas appliance. The installation must conform with local codes or, in the absence of local codes, with the cur rent National Fuel Gas Code, ANSI Z223.1/ NFPA 54. This appliance complies with ANSI Z21.50.
BEFORE YOU BEGIN Before beginning installation of your appli ance, read these instructions completely.

The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.
To determine the safest and most efficient location for your appliance, you must take into consideration the following guidelines: 1. The location must allow for proper clear ances (see Clearances, page 7). 2. Consider a location where heat output would not be affected by drafts, air con ditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 1 shows a plan view of a few com mon locations. Flush installations are recommended where living space is limited or at a premium and since the space required to enclose the ap pliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions. Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.
Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference. Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.
INTERNAL WALL INSTALLATION
FLUSH INSTALLATION
FULL PROJECTION INSTALLATION
Figure 1 - Possible Locations for
Installing Appliance

21 1/2"

22 3/8" For Use With B-1 Vent Pipe
* 13 3/4" 14 1/2"
2 1/2" 8 1/4"
35 3/8" 29 1/2"
7 5/8" 10 5/8"
Figure 2 - Appliance Dimensions

MANTEL CLEARANCES and Wall Details A combustible mantle shelf maybe installed a maximum 12" (22.90 cm) from the wall. Figures 5 and 6 show the minimum allow able distances from various combustible mantle components in relation to the fireplace opening.

1" (2.5 cm) Min. Clearance to "B" Vent's Outer Pipe
42" (10.67 cm) Min. Clearance from Opening to Ceiling
3" (7.6 cm) Max. 6" (15.2 cm) Max. 9" (22.86 cm)
Required Air Spaces are Indicated with an "*". Do Not Pack with Insulation or Any Other Material
(Front View)

FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line enclosure, then all measurements must be from surface of covering. 2. Place appliance into framing and secure. Note: If appliance is to be raised above floor level, a platform must be built to support appliance. 3. Install supply line to appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above bottom of appliance. The gas line must be installed through the lower left side access point or alternate access hole in bottom of appliance (see Figure 16, page 12). 4. Feed flexible gas line through one of three gas line conduit sleeves and repack insu lation to cover any openings. Prepare the incoming gas line with teflon tape or pipe joint compound and hook up incoming gas line to flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at end of flexible gas line, remove fitting and replace with a 37° flare 3/4"-12, 1/2" NPT (female) fitting.
36 5/8"
16 1/8"
34 3/4"
Figure 7 - Rough Opening for Installing
These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted
39 3/8"
16 3/4"
55 5/8" 34 1/2"
3/4" Clearance Not Required at Nailing Flanges
Figure 8 - Corner Installation Guidelines
A B-type venting system must be connected to appliance for venting to outside of building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B- type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check
with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code ANSI Z223.1/NFPA 54. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid fuel burning appliance.
in Wall · 12" · 16"

This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chim ney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 9 are typi cal of most B-vent installations and codes practices. Example 1: Shows the minimum allowable system height and lateral offset for a 60° or greater inclination. Code specifies that offsets at 60° or greater are considered horizontal and must follow the 75% rule for lateral to total vertical system height. Codes also al lows only one offset in the total system when at 60° or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows a multiple offset each at 45° of inclination. Multiple offsets are permit ted if they do not exceed 45° of inclination. The total lengths of the two offsets are not required to meet the 75% allowable rule. Example 3: Shows a single offset at 45° of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% rule.
In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceil ing joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained. Vent terminations must be located in ac cordance with height and proximity rules of NFPA No. 54. These rules apply to vents at 12" diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 feet distance from a vertical wall or obstruction (see Figure 10, page 10). If venting horizontally through a side wall be comes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing B- type vent systems if the system is at or above the recommended diameter of the flue. The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation.
Listed Vent Cap Listed Vent Cap
Maintain Listed Clearance Maintain Listed Clearance
Lateral At Least Every
12' Min. 45°
Position Firestop Position Firestop
12' Min.
12' Min.
Figure 9 - Typical B-Vent Configuration

It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in ac cordance with the common venting guides Appendix G of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1. Note: Before connecting this appliance to an existing vent system or a common venting system consult with your local architect, plan ner, or building official.
CHECKING FOR PROPER VENTING After completing and checking electrical, gas and vent connections, follow lighting instructions and allow main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near top edge of fireplace opening and play it along entire length of the opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance. If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.
8 Ft. Min.
x Listed Gas Vent
Roof Pitch x/12 Listed Clearance
H (Min) Height From Roof
Check this area along entire top edge of fireplace opening. Smoke or flame should be drawn into appliance opening.
Figure 11 - Checking for Spillage
Figure 10 - B-Vent Terminations
Lowest Discharge Opening · Listed Vent Cap

WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to Wiring Diagram, page 21.

Optional Remote control INSTALLATION (model WRC) Note: If using optional wireless hand-held remote control, wall switch must be in ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. 1. Remove front refractory access panel by lifting up and angling out of firebox open ing (see Figure 12). 2. WRC model receiver does not require a battery. Receiver can be installed by first plugging short extension cord into fireplace receptacle. Plug receiver unit into exten sion cord. Finally, plug ignition module plug into receiver unit (see Figure 13). 3. Activate remote handset battery by re moving insulating tab on back of handset (see Figure 14). Battery is included pre- installed. 4. Once battery is activated, unit is ready to use. 5. Replace front refractory access panel.
Figure 14 - Installing Battery into Back of

Figure 12 - Removing Front Refractory
Access Panel (P325E/VP325E Model
Handset · Shown)

WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a commercial leak detection solution to all con nections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pressure testing of gas supply piping system at test pres sures equal to or less than 1/2 psig (3.5 kPa). An equipment shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 15. In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 16.
Complete your gas installation by connect ing incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.

FMI PRODUCTS, LLC recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 17, page 13) and into appliance. Once connected through appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 18, page 13). Before connecting black iron gas line to inside of appliance a sediment trap must be included outside appliance between gas line and gas shutoff valve. It must extend down 3" beyond center of pipe. Prepare incoming black iron gas line with teflon tape or pipe joint com pound (Check with local building codes).
Typical Exterior Wall Gas Shutoff Installation
Figure 15 - Shutoff Valve Installation

Flexible Gas Line (1 Provided) Can Be Extended Out Either Side
83/8" 105/8"
Figure 16 - Routing Incoming Gas Line
Shutoff Valve · Extension

Sediment Trap (Not Supplied)

Red Surface Indicates For Propane/LP Use Only

Figure 18 - Connecting Flexible Gas Line to Millivolt Valve
Grate Placement The grate must be placed in the burner pan so that the back grate fingers (P325E/VP325E) or pins (P324E/VP324E) fit into notches on back of burner pan and front legs fit inside burner pan as shown in Figure 19.

P325E/VP325E
Figure 19 - Placing Grate into Burner Pan

EMBER AND PAN MATERIAL placement 1. Open bag(s) of vermiculite and fill entire burner pan until burner tube is completely covered (see Figure 20). 2. Smooth pan material just even with edges of burner pan. 3. Remove ember material from bag and flatten small amounts into quarter size pieces and lay on top of surface of pan material (see Figure 21). 4. Place just enough to cover entire surface and leave about a 1/2" gap under lower grate members to allow air to flow (see Figure 22).
LOG PLACEMENT For P324E/ VP324E Models 1. Place front log (log 1) onto front of grate sliding log all the way forward against grate fingers (see Figure 23). 2. Insert pegs on bottom of rear log (log 2) into holes in rear of grate (see Figure 23). 3. Place log 3 into notches on left side of logs 1 and 2 (see Figure 24, page 15). 4. Place log 4 into notches on right side of logs 1 and 2 (see Figure 24, page 15). To enhance the look of the hearth you may optionally place provided lava rock around front and sides of burner.

Figure 22 - Pan and Ember Material
Clearances

3. Rest front of log 3 between first two grate fingers on left of grate assembly and rear of log 3 into notch on left front of log 1(see Figure 26). 4. Place top of log 4 into notch on log 1. Rest log 4 on center of grate as shown in Figure 27. 5. Place top of log 5 into notch on top right of log 1 (see Figure 27). Rest log 5 be tween two middle grate fingers as shown in Figure 28, page 16 To enhance the look of the hearth you may optionally place provided lava rock around front and sides of burner.


Figure 24 - Installing Logs 3 and 4
LOG PLACEMENT For P325E(B)/ VP325E(B) ModELs 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 25). 2. Place log 2 onto front right side of grate and back of log 2 into notch on right front of log 1 (see Figure 25).

Figure 25 - Installing Logs 1 and 2
Figure 27 - Installing Logs 4 and 5
Log 4 · Log 1

APPLIANCE ENCLOSURE Before finishing enclosure around appliance, inspect all joints around outer surround. Any gaps between nailing flanges and framing should be sealed with noncombustible insula tion or caulking. If mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent entry of cold air by means of conduction through total bot tom of appliance (see Figure 30).

Caulk Here Pack Insulation
Figure 30 - Sealing Between Appliance
Figure 28 - Logs Installed
COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of fireplace only. The vent can be installed through any outside wall a minimum of 3 feet below fireplace termination cap. The handle to operate damper door for the outside air inlet will be located inside the left “screen pocket” of firebox (see Figure 29). Pull handle to open or push to close.
Note: Glass door may be heavy for some individuals. If this is the case, please request help. These B-vent fireplaces are approved for use with optional bi-fold glass doors (see Ac cessories, page 25). The glass panels may be ordered and installed anytime after the fireplace installation is complete. Follow these steps to install left and right panels: 1. With handle at the bottom, completely fold panel on its hinges. 2. With handle facing center of firebox open ing, insert lower pivot pin on glass door panel into hole in pivot plate on bottom edge of fireplace opening (see Figure 31, page 17). 3. Keeping folded door tilted, slide upper two pins into guide track found under upper facial edge of firebox opening.

Side Framing · Side Framing · and Framing

4. Tilt glass assembly fully vertical until outer pivot pin snaps into mounting hole in up per spring clip (see Figure 31). 5. Once top and bottom pins are secured, unfold door into closed position. 6. Repeat process for opposite door as sembly. 7. To adjust doors, slide them partially open. Using a screwdriver, loosen hold-down screws in spring clip and pivot plate (see Figure 32). 8. Close both doors until evenly joined at middle and note gap at outer edges of the face. 9. Reopen one door at a time and retighten upper and lower hold-down screws. 10. Repeat process until both doors are even ly joined, spaced and working freely.
Figure 32 - Adjusting Glass Doors
Removing Glass Doors for Replacement or Cleaning 1. Partially open door and press up on upper spring clip with a screw driver until outer top pivot pin is free of clip. 2. Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail (see Figure 33).
Spring Clip Insert Pin Into Spring Clip
Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track
Slide Top Pin Into Door Track
Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position
Depress Spring Clip to Release Pivot Pin
Figure 31 - Installing Optional Glass
Remove Bottom Pin From Pivot Plate While Sliding Door Out of Upper Track
Figure 33 - Removing Glass Doors

A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around
the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a quali fied service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Figure 34 - Turning Equipment Shutoff
Valve to the OFF Position
Adjustment Screw · Equipment Shutoff Valve

TO APPLIANCE 1. Turn off wall switch. 2. Turn off all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
OPERATION Note: The WRC receiver and hand-held re mote control kit must be purchased separately (see Accessories, page 25). Follow installa tion instructions on page 11. Turn equipment shutoff valve to the ON posi tion. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

Figure 35 - Pilot


Figure 36 - Correct Pilot Flame Pattern
P325E(B) and VP325E(B) Models
Figure 37 - Typical Flame Pattern

WARNING: Installation and repair should be done by a quali fied service person. The appli ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys tem be kept clean.
Technical Service You may have further questions about instal lation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328- 4537. When calling please have your model and serial numbers of your heater ready. You can also visit our web site at www.fmiproducts.com.

120V AC INCOMING
120v, 60Hz, 0.7A ELECTRICAL RATING:
GREEN
WHITE
OFF
(SUPPLIED) WALL SWITCH
OPTIONAL
CONTROL
REMOTE
GREEN
BLACK WHITE
ON
TRANSFORMER
STEP DOWN
120V AC
24V AC
PV GND PV/MV TR MV TH IGN
VENT SAFETY
SHUTOFF
SWITCH
TO GAS LINE
BURNER
INCOMING
MAIN GAS
SUPPLY
EV1
EV2

Troubleshooting Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Ignitor will not spark or pilot will not light
1. Check to see if you have gas supply and that equip ment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after re peated attempts appliance does not light, call for quali fied service and repair. 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (Re fer to Replacement Parts, page 20) 7. Check that main power is on and that all wire connec tions are made correctly to ignition model (see Wiring Diagram, page 21). Check for 24 VAC at secondary side of transformer. If 24 VAC is present, and mod ule does not operate, have module replaced, otherwise have transformer replaced 8. Open vent damper until fully locked in the OPEN position
Pilot will not stay lit

POSSIBLE CAUSE
REMEDY
No gas to burner, although wall switch and valve are set to the ON position
Fireplace produces a clicking/ ticking noise after burner is lit or shut off
Fireplace produces unwanted odors
Gas odor even when equip ment shutoff valve is in OFF position
Gas odor during combustion
Frequent pilot outage

POSSIBLE CAUSE
REMEDY
Dark residue on logs or inside of fireplace

Accessories Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back page of this manual.
Air kit - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
32" Perimeter Trim kit PT32 - Black PT32B - Brushed Brass PT32P - Platinum
Remote Control Kits WRC - Standard On/Off Electronic Remote Control Kit GWMS2 - Wall Mount ON/OFF Switch
32" Louver Trim kit (Rolled Louvers Only) LT32B - Brushed Brass LT32P - Platinum
Propane Conversion Kits PCBE-324 - 4" B-Vent Electronic Fireplace PCBE-325 - 5" B-Vent Electronic Fireplace
Face/Louver Panel Kits SP32 - Smooth Faced, Black SL32 - Stamped Louver, Black RL32 - Rolled Louver, Black FP32 - Filigree Panel, Black FP32B - Filigree Panel, Brushed Brass FP32P - Filigree Panel, Platinum
32" Extruded aluminum bi-fold glass doors BD32 - Black Finish BD32B - Brushed Brass Finish BD32P - Platinum Finish
FIre crackle - CF6-A1 Creates the sound of a real burning fire. 32" Fixed Glass Door Kit FD32 - Black Finish FD32B - Brushed Brass Finish FD32P - Platinum Finish
32" Brick Liner kit BL32 - Refractory Standard Brick Liner Kit
Blower Kit BK - Squirrel Cage Blower With Speed Control



Parts Models P324E and VP324E This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.
KEY NO. PART NO. DESCRIPTION QTY. 1 108769-03 Extension Deflector 2 2 109098-01 Wire Assembly Electric Harness 1 3 108864-01 Strain Relief 1/2" Bushing 1 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 108863-01 24" Supply Connect Plug 1 7 14253 Flexible Supply Line with Shutoff Valve 1 8 108411-01 Air Separator 1 9 11186 Screw, #8-32 x 1" PPH Zinc. 2 10 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 11 11201 Nut, #8-32 Hex Zinc. 4 12 108428-03 Bottom Front Refractory, Std. Brick 1 13 108426-03 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 14301 Ignition Module 1 18 11165 Screw, #10x5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108416-01 4" Collar 1 21 108412-01 Smoke Deflector 1 22 108415-01 Starter Pipe Collar 1 23 109797-01 Grate Assembly 1 24 109107-02 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109794-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 109793-01 Divider Pan 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24x1/2 1 24-8 901066-01 Brass Air Mixer (NG) 1 901066-02 Brass Air Mixer (LP) 1 24-9 901064-12 Injector (NG) 1 901065-11 Injector (LP) 1 24-10 108866-01 Pilot (Natural Gas) 1 24-11 108867-01 Pilot Orifice (LP) 1 24-12 11102 Screw, #8-32x3/8 2 25 14569 Electronic Gas Valve (NG) 1 14570 Electronic Gas Valve (LP) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 106827-01 4" Gasket 1 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assembly, Left 1 43 108654-01 Gas Conduit Assembly, Right 1 44 20280 Top Spacer 4 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1



Parts Models P325E(B) and VP325E(B) This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.
KEY NO. PART NO. DESCRIPTION QTY. 1 108769-03 Extension Deflector 2 2 11201 Nut, #8-32 Hex Zinc. 2 3 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 11186 Screw, #8-32 x 1" PPH Zinc. 2 7 109098-01 Wire Assembly Electric Harness 1 8 108411-01 Air Separator 1 9 108434-01 Left Refractory, Std. Brick (B Models) 1 10 108432-01 Right Refractory, Std. Brick (B Models) 1 11 108430-01 Rear Refractory, Std. Brick (B Models) 1 12 108428-01 Bottom Front Refractory, Std. Brick 1 13 108426-01 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 108864-01 Strain Relief 1/2" Bushing 1 18 11165 Screw, #10 x 5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108863-01 24" Supply Connect Plug 1 21 108412-01 Smoke Deflector 1 22 14253 Flexible Supply Line with Shutoff Valve 1 23 109040-01 Grate Assembly 1 24 108712-06 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109037-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 901681-01 Burner Clamp 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24 x 1/2 1 24-8 901066-01 Brass Air Mixer (NG) 1 901066-02 Brass Air Mixer (LP) 1 24-9 901064-11 Injector (NG) 1 901065-09 Injector (LP) 1 24-10 108866-01 Pilot (NG) 1 24-11 108867-01 Pilot Orifice (LP) 1 24-12 11102 Screw, #8-32 x 3/8 2 25 14569 Electronic Gas Valve (NG) 1 14570 Electronic Gas Valve (LP) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 22084 Brick Liner Retainer 2 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assembly, Left 1 43 108654-01 Gas Conduit Assembly, Right 1 44 20280 Top Spacer 4 45 108415-01 Starter Pipe Collar 1 46 108417-01 5" Collar 1 47 14301 Ignition Module 1 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1



P324E and VP324E Models
P325E(B) and VP325E(B) Models
KEY NO. PART NO. DESCRIPTION QTY. - 109109-01 Log Set 1 105958-05 Front Log 1 2 105960-05 Rear Log 1 3 901100-02 Top Right Log 1 4 901102-02 Top Left Log 1
KEY NO. PART NO. DESCRIPTION QTY. - 109100-02 Log Set 1 109421-01 Rear Log 1 2 109420-01 Front Right Log 1 3 108723-01 Front Left Log 1 4 108722-01 Top Y-Log 1 5 108720-01 Top Log 1




Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties: Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented. This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product. This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner. Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s). This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) year on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product. FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
108794-01 Rev. G 09/09
1-866-328-4537 www.fmiproducts.com
Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.