VENT-FREE COMPACT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL

FMI VMH26TNC — VENT-FREE COMPACT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL diagram (page 1)
Fig. 2

PFS ®

US

Shown with Optional Cabinet Mantel/Hearth Base Accessory

Models VMH26TPC and VMH26TNC 14,000 to 26,000 Btu/Hr with Thermostat

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali-

fied installer, service agency, or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Page 2 of the FMI VMH26TNC user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 2 · click to enlarge
Page 2

Table of Contents

Safety 2 Local Codes 4 Product Identification 4 Product Features 5 Unpacking 5 Assembly 5 Air for Combustion and Ventilation 6 Installation 9 Operation 19 Inspecting Burner 22

Cleaning and Maintenance 23 Troubleshooting 24 Specifications 28 Service Hints 28 Technical Service 28 Replacement Parts 28 Accessories 29 Parts 30 Warranty Back Cover

Safety

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than oth- ers. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-mak- ing agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer
Page 3 of the FMI VMH26TNC user manual — SAFETY
Page 3 · click to enlarge
Page 3

SAFETY

Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

  • 1. This appliance is only for use with type of gas indicated on rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP only). 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This fireplace shall not be installed in a bedroom or bathroom. 5. Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace. 6. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. 7. This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues. 8. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance , page 23. 9. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.

Fireplace front and screen be- come very hot when running fire- place. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace.

You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen is in place before running fireplace.

Page 4 of the FMI VMH26TNC user manual — Product Identification
Page 4 · click to enlarge
Page 4

SAFETY

  • 10. This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation , page 6. If fireplace keeps shutting off, see Troubleshooting , page 24. 11. Do not run fireplace
  • where flammable liquids or vapors are used or stored.
  • under dusty conditions. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water.

14. Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. 15. Operating fireplace above elevations of 4,500 feet could cause pilot outage. 16. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger). 17. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity (propane/LP only). 18. Provide adequate clearances around air openings.

Local Codes Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.

Product Identification

FMI VMH26TNC — Product Identification diagram (page 4)
Fig. 3 · Product Identification

1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

FMI VMH26TNC — Product Identification diagram (page 4)
Fig. 4 · Product Identification

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Figure 1 - Vent-Free Gas Compact

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

Show 4 more labels / short text on this page
Screen · Logs · Ignitor Button · Fireplace
Page 5 of the FMI VMH26TNC user manual — Assembly
Page 5 · click to enlarge
Page 5

Product Features

Safety Pilot This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Thermostatic Heat Control This fireplace has a thermostat sensing bulb and a control valve. The thermostat will auto- matically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

Piezo Ignition System This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

Unpacking

1. Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time. 2. Remove all protective packaging applied to fireplace for shipment. 3. Make sure your fireplace includes one hardware packet.
4. Check fireplace for any shipping damage. If heater is damaged call FMI PRODUCTS, LLC at 1-866-328-4537 for replacement parts before returning to dealer.

Assembly

4. Remove log packaging material and discard packaging. Gently place log set on burner support (see Figure 2). The log should fit flat against top of burner support and log locator tabs fit into the slots under the log. Do not allow log to contact flame. If flame contacts log, soot will be created. 5. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

with Log Locator Tabs

  • Assembling Fireplace Tools Required:
  • Phillips screwdriver
  • 5/16" hex wrench
  • slotted screwdriver

Installing Log 1. Lift screen up and pull out to remove. 2. Cut two plastic straps to remove the log from the firebox cavity. 3. An optional blower is available. See Ac- cessories, page 29. Install optional blower now. Follow installation instructions pro- vided with blower.

Figure 2 - Assembling Fireplace

Show 5 more labels / short text on this page
Burner Support · Shoulder Screw · Log · Screen · Branch Support
Page 6 of the FMI VMH26TNC user manual — Air for Combustion and Ventilation
Page 6 · click to enlarge
Page 6

Assembly

Assembling Hood 1. Locate four black phillips sheet metal screws from the hardware packet. 2. Rotate hood as shown in Figure 3. Make sure hood tabs point toward fireplace. 3. Insert hood tabs between baffle and lou- vers (see Figure 3). 4. Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 3). 5. Align screw holes on hood with screw holes on firebox top. 6. Insert screws as shown in Figure 3. Tighten screws firmly.

FMI VMH26TNC — Assembly diagram (page 6)
Fig. 5 · Assembly

Figure 3 - Assembling Hood

Air for Combustion and Ventilation

FMI VMH26TNC — Air for Combustion and Ventilation diagram (page 6)
Fig. 6 · Air for Combustion and Ventilation

air for these appliances. This will insure proper venting of vented fuel-burning appliances.

WARNING: This heater shall not be installed in a room or space unless the required vol- ume of indoor combustion air is provided by the method de- scribed in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.

Today’s homes are built more energy efficient than ever. New materials, increased insula- tion, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap- pliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un- usually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out-

side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on

openable windows and doors and

Firebox Top

Page 7 of the FMI VMH26TNC user manual — DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Page 7 · click to enlarge
Page 7

AIR FOR COMBUSTION AND VENTILATION

c. caulking or sealants are applied to

2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support (volume of space) x 20 = (Maxi- mum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace + Btu/Hr Total = Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ Hr used Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the

areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location.

Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1.3/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag- gregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un- confined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

space can support) 56,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup- port. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with door- less passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 8. B. Vent room directly to the outdoors. See

Ventilation Air From Outdoors, page 8. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr

size makes room unconfined. If the actual Btu/Hr used is less than the maxi- mum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

30,000 26,000 56,000

Page 8 of the FMI VMH26TNC user manual — VENTILATION AIR
Page 8 · click to enlarge
Page 8

AIR FOR COMBUSTION AND VENTILATION

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo- stat-controlled power vent. Heated air entering the attic will activate the power vent.

FMI VMH26TNC — AIR FOR COMBUSTION AND VENTILATION diagram (page 8)
Fig. 7

VENTILATION AIR

Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

O Aiu rtlet V Ae ttn ict ilated tlet let irTo Attic To Crawl Space Ventilated Inlet Air Crawl Space
FMI VMH26TNC — VENTILATION AIR diagram (page 8)
Fig. 8

Figure 5 - Ventilation Air from Outdoors

FMI VMH26TNC — VENTILATION AIR diagram (page 8)
Fig. 9

Shown with Optional Mantel

Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel

Page 9 of the FMI VMH26TNC user manual — Installation
Page 9 · click to enlarge
Page 9

IMPORTANT: Vent-free fireplaces add mois- ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6. Note: Your VANTAGE HEARTH fireplace is designed to be used in zero clearance instal- lations. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or fram- ing materials. Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 10).

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

  • WARNING: Never install the fireplace
  • in a bedroom or a bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36" from the front, top, or sides of the fireplace
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas
  • INSTALLATION ITEMS Before installing fireplace, make sure you have the items listed below.
  • external regulator - propane/LP only (supplied by installer)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection*
  • ground joint union
  • sediment trap
  • tee joint
  • pipe wrench * A shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer. Note: If desired, purchase a four-sided trim kit for built-in installations. See Accessories, page 29.
Page 10 of the FMI VMH26TNC user manual — LOCATING FIREPLACE
Page 10 · click to enlarge
Page 10

LOCATING FIREPLACE

  • CAUTION: If you install the fireplace in a home garage
  • fireplace pilot and burner must be at least 18" above floor.
  • locate fireplace where moving vehicle will not hit it.

You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels speci- fied in this manual. Purchase the optional mantel from your dealer (see Accessories, page 29).

  • For convenience and efficiency, install fireplace
  • where there is easy access for operation, inspection, and service.
  • in coldest part of room. An optional blower kit is available from your dealer (see Accessories , page 29). If planning to use blower, locate fireplace near an electrical outlet.
FMI VMH26TNC — LOCATING FIREPLACE diagram (page 10)
Fig. 10

Built-In Fireplace Installation Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional trim kit accessory is available (see Accessories, page 29). Trim will extend past sides of fireplace approximately 1/2". This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace you must follow the clearances shown in Figure 11, page 12. Follow the instructions below to install the fireplace in this manner.

0” Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 6 - Mounting Clearances As Viewed From Front of Fireplace Shown

FMI VMH26TNC — LOCATING FIREPLACE diagram (page 10)
Fig. 11
ActualFraming Height26"26 7/8" Front Width26 3/4"26 7/8" Depth9 1/2"10 1/2" Bottom3/4"3/4"
1. Frame in rough opening. Use dimensions shown in Figure 8, page 11, for the rough opening. If installing in a corner, use dimensions shown in Figure 9, page 11, for the rough opening. The height is 26 7 / 8 " which is the same as the wall opening above.

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown

Built-In the Wall · with Optional Mantel

Page 11 of the FMI VMH26TNC user manual — Installation
Page 11 · click to enlarge
Page 11

2. If installing GA3450TA blower accessory, do so at this time. See Installing Blower Accessory GA3450TA, page 13. Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installa- tion (see Accessories, page 29) Use only approved three-wire electrical wiring. Note: A qualified installer should make all electrical connections. 3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not assembled firebox, follow instructions on page 4. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Connecting to Gas Supply, page 16. 7. Bend four nailing flanges on outer casing with pliers (see Figure 10). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Connections, page 18. 10. If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim acces- sory for attaching trim.

10 1/2"

267/8"

3/4" Off The Floor Minimum

267/8"

Figure 8 - Rough Opening for Installing

365/8" 257/8"

513/4" 267/8"

Figure 9 - Rough Opening for Installing

FMI VMH26TNC — Installation diagram (page 11)
Fig. 12 · Installation

Nails or Wood Screws

Figure 10 - Attaching Fireplace to Wall

in Wall · in Corner · Studs

Page 12 of the FMI VMH26TNC user manual — Installation
Page 12 · click to enlarge
Page 12

OPTIONAL MANTEL Installation Refer to instructions provided with the mantel for assembly instructions. Refer to the follow- ing instructions for system installation. Refer to instructions on page 6 for hood assembly. Blower accessory should be installed prior to mantel if it is being used (see Installing Optional Blower Accessory GA3450TA, page 13). 1. Assemble cabinet mantel as shown in accessory instruction sheet. 2. If blower is installed, install a properly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 12). 3. Place hearth base against wall at installa- tion location. Cut an access hole in hearth base to run gas line to fireplace (see Figure 12). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over. 4. Route flexible gas line through access hole in hearth base. 5. Center cabinet mantel on hearth base (see Figure 13, page 13). Make sure mantel is flush against wall and centered left to right on base. 6. Use screws provided with mantel accessory to attach mantel assembly to base (see mantel instruction sheet). 7. Attach flexible gas line to fireplace gas regulator. See Connecting to Gas Supply, page 16. 8. Route electrical cord(s) through access holes in either side of fireplace with bushing. Plug electrical cord(s) into electrical outlet.

Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between man- tel shelf and top of fireplace opening.

  • NOTICE: If your installation does not meet the minimum clearances shown in Figure 11, you must do one of the following:
  • raise the mantel to an acceptable height
  • remove the mantel

10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.

2 1/2"

Electrical Outlet Pipe and Gas Shutoff Valve

Figure 12 - Placing Hearth Base Against Wall

Figure 11 - Minimum Mantel Clearances

Show 10 more labels / short text on this page
Mantel Shelf · 8" · 6" · 13" · 16" · 19" · 21" · Hearth Base · Side of Firebox · for Built-In Installation
Page 13 of the FMI VMH26TNC user manual — Installation
Page 13 · click to enlarge
Page 13

9. Check all gas connections for leaks. See Checking Gas Connections, page 18. 10. Carefully insert fireplace into cabinet mantel (see Figure 13). Be careful not to scratch or damage hearth base or cabinet mantel. 11. Place metal trim on shoulder screws locat- ed on the side and top of the fireplace (see Assembling Perimeter Trim). Firmly snap trim over shoulder screws. Align fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides. 12. Lower bottom louver door. Use 3" wood screws provided with mantel accessory to attach fireplace to base (see mantel instruction sheet).

4. Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 14). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 14). 6. While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other corner. 8. Set trim assembly aside for later installation.

installing blower accessory GA3450TA Removing Upper Louver Assembly To install the blower accessory, you must first remove the upper louver assembly. 1. Lift screen off heater. 2. Remove 4 screws from louver assembly (see Figure 15). Save these screws. 3. Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.

FMI VMH26TNC — Installation diagram (page 13)
Fig. 13 · Installation
FMI VMH26TNC — Installation diagram (page 13)
Fig. 14 · Installation

Figure 13 - Installing Fireplace into

Assembling Perimeter Trim 1. Remove packaging from three remaining pieces of trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 14.

Figure 15 - Removing Upper Louver

Removing Valve Cover Shield 1. Open bottom louver assembly by swing- ing the assembly down (see Figure 16, page 14). 2. Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clock- wise and slide out. IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoul- der screw (see Figure 16, page 14).

FMI VMH26TNC — Installation diagram (page 13)
Fig. 15 · Installation
Show 5 more labels / short text on this page
Mantel Assembly · Assembly · Top Trim · Adjusting Plate · Side Trim
Page 14 of the FMI VMH26TNC user manual — Installation
Page 14 · click to enlarge
Page 14

4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of heater cabinet, locate 4 mounting holes on outer casing. Align these 4 holes with those on blower bracket assembly. Attach blower bracket assembly to outer casing with 4 #10 screws provided (see Figure 17). 6. Route wire harness through hole in left side of baffle. Pull wire harness through lower opening above where valve shield was removed (see Figure 17). 7. Insert 4 wire harnesses into one of the round holes in rear of valve cover shield and through rectangular hole in front of shield (see Figure 17). 8. Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires. 9. Install switch plate on valve cover shield with 2 #10 screws provided (see Figure 18, page 15). Reinstall valve cover shield. Route power cord out of cabinet by inserting it through bushing on outer casing (see Figure 17). Plug fan kit into 120-Volt grounded power supply and test operation. Installing Blower Assembly

Snap Bushings Bottom Louver Assembly

Figure 16 - Removing Valve Cover Shield

Wiring Routing Hole in Baffle

Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In Installation on page 15. 1. Install snap bushings found in hardware kit into both holes in rear of valve cover shield. 2. Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly. 3. Note wire locations on back of AUTO/OFF/ ON switch. Terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 17).

Box Cover Wire Harness

Figure 17 - Installing Blower Bracket

Show 15 more labels / short text on this page
Branch Support · Shoulder Screw · Valve Cover Shield · Remove Screw · Blower Bracket Assembly · Wire Harness · Screw · Baffle · Switch · Power Cord · Red · Switch Plate · Blue · Valve Cover Shield · Assembly
Page 15 of the FMI VMH26TNC user manual — (N.O.)
Page 15 · click to enlarge
Page 15

Note: When switch is in AUTO position, fan will start after heater has run for a few moments. Fan will continue to run for several moments after heater has been turned off. When switch is in the ON position, fan will run until turned to OFF. Reinstall upper louver assembly and hood if previously removed, (see Figure 15, page 13). Close lower louver door.

4. A licensed electrician must follow the wir- ing diagram to connect incoming electri- cal supply to fan kit wiring harness (see Figure 19). 5. Plug power cord to the outlet receptacle (not provided) as shown in Figure 18. Wind the extra power cord and tie it up with the plastic wire strap (see Figure 20, page 16). Set the power cord bundle between the burner bracket and outer casing, away from the burner. 6. Reinstall valve cover shield. 7. Test to make sure the blower is working properly. 8. Reinstall upper louver assembly and hood if previously removed, (see Figure 15, page 13). Close lower louver door.

Figure 18 - Installing Switch Plate to

110/115 V.A.C. Blower

(N.O.)

Follow instructions for Removing Valve Cover Shield, page 13. Continue installation as follows: 1. Install a snap bushing found in hardware kit into one of the holes found on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply. 2. Follow steps 2 through 6 in Installing Blower Assembly, page 14. Also remove black wire from middle switch terminal 2. 3. Remove black plastic strain relief and power cord from switch plate. The power cord supplied will not be used in built-in installa- tions. Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord/strain relief.

Figure 19 - Wiring Diagram For Blower

Show 20 more labels / short text on this page
Valve Cover Shield · Switch Plate · Screw · Motor Black · Valve Cover Shield · For Built-In Installation · Thermostat · Switch · Blue · Red · Green White · Blue · Auto · Fan Switch · (Auto/Off/On) · Red · On · Off · Green White · Accessory Built-In Installation
Page 16 of the FMI VMH26TNC user manual — CONNECTING TO GAS SUPPLY
Page 16 · click to enlarge
Page 16
FMI VMH26TNC — Installation diagram (page 16)
Fig. 16 · Installation

For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regula- tor with the vent pointing down as shown in Figure 21. Pointing the vent down protects it from freezing rain or sleet.

Clamp Connector (not included)

Figure 20 - Installing Blower Bracket

Extension Cord Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

CONNECTING TO GAS SUPPLY

Propane/LP Supply Tank External Regulator

Figure 21- External Regulator with Vent

Show 4 more labels / short text on this page
Box Cover · Assembly · Vent Pointing Down · Pointing Down
Page 17 of the FMI VMH26TNC user manual — Installation
Page 17 · click to enlarge
Page 17

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Lo- cate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22). IMPORTANT: Install equipment shutoff valve in an accessible location. Equipment shutoff valve is for turning on or shutting off gas to the appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

2. Remove screws that attach branch support to fireplace (see Figure 23). Carefully lift up branch support and remove from fireplace (see Figure 23). 3. Route flexible gas line included from fireplace control to equipment shutoff valve through side or rear access holes in outer casing.

Equipment Shutoff Valve With 1/8" NPT Tap*

4. Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Figure 24, page 18). 5. Check all gas connections for leaks. See Checking Gas Connections, page 18.

PROPANE/LP From External Regulator (11" W.C. to 14" W.C. Pressure) NATURAL From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Pipe Cap Tee Nipple Joint

Figure 22 - Gas Connection

* Purchase the optional equipment shutoff valve from your dealer.

  • CONNECTING Equipment shutoff valve to heater control Installation Items Needed
  • Phillips screwdriver
  • sealant (resistant to propane/LP gas, not provided) 1. To remove fireplace screen, remove 2 screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

Figure 23 - Removing Log Base

Show 8 more labels / short text on this page
3" Minimum · Shoulder Screw · Branch Support · Screen Shipping Screw · Sediment Trap · Flexible Gas Line · Screen · Assembly From Fireplace
Page 18 of the FMI VMH26TNC user manual — CHECKING GAS CONNECTIONS
Page 18 · click to enlarge
Page 18
6. Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reattach branch support to fireplace with screws removed in step 2, page 17.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply piping. Pressures in excess of 1/2 psig will dam- age fireplace regulator. 2. Cap off open end of gas pipe where equip- ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping sys- tem. Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

To Fireplace Gas Regulator Equipment Shutoff Valve Provided by Installer

Flexible Gas Line from Fireplace Gas Regulator Provided with Fireplace

PROPANE/LP To External Regulator NATURAL To Gas Supply

Figure 24 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

CHECKING GAS CONNECTIONS

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 25). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural or propane/LP supply to equipment shut- off valve (see Figures 26 and 27, page 19). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 25 - Equipment Shutoff Valve

Equipment Shutoff Valve · Open · Closed

Page 19 of the FMI VMH26TNC user manual — Operation
Page 19 · click to enlarge
Page 19

Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 25, page 18). 2. Open main gas valve located on or near gas meter for natural gas or open pro- pane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ures 26 and 27). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operation). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 21). 8. Replace front panel.

FMI VMH26TNC — Operation diagram (page 19)
Fig. 17 · Operation

Figure 26 - Checking Gas Joints for Propane/LP Gas (Shown with Optional

FMI VMH26TNC — Operation diagram (page 19)
Fig. 18 · Operation

Figure 27 - Checking Gas Joints for Natural Gas (Shown with Optional Mantel)

FMI VMH26TNC — Operation diagram (page 19)
Fig. 19 · Operation
  • WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn

A. This appliance has a pilot which must

be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around

the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a quali- fied service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part

the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Equipment Shutoff Valve · Mantel)

Page 20 of the FMI VMH26TNC user manual — LIGHTING INSTRUCTIONS
Page 20 · click to enlarge
Page 20

OPERATIon

LIGHTING INSTRUCTIONS

Note: If pilot does not stay lit, refer to Troubleshooting, page 24. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21. 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

1. STOP! Read the safety information start- ing, page 19. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in safety information, page 19. If you don’t smell gas, go to next step. 5. Turn control knob counterclockwise to PILOT position. Press in control knob for five (5) seconds (see Figure 28). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. Pilot is attached to front of burner. If needed, keep pressing ignitor button until pilot lights.

9. To shut off burner only and leave pilot lit, turn countrol knob clockwise to PILOT position.

Figure 28 - Control Knob In The OFF

Figure 29 - Pilot (Propane/LP Shown)

Show 5 more labels / short text on this page
Ignitor Button · Control Knob · Position · Thermocouple Pilot Burner · Ignitor Electrode
Page 21 of the FMI VMH26TNC user manual — OFF
Page 21 · click to enlarge
Page 21

OPERATIon

TO TURN OFF GAS

MANUAL LIGHTING

TO APPLIANCE

PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 20. 2. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 20.

Shutting Off Fireplace 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. 3. Close equipment shutoff valve (see Figure 25, page 18).

THERMOSTAT CONTROL OPERATION The thermostatic control used on this fireplace differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Note: The thermostat sensing bulb measures the temperature of air near the fireplace cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

Operating

Blower This blower has three settings: ON, OFF, and AUTO. In the ON position, blower will operate constantly. In the OFF position, blower will not operate. In the AUTO position, blower will start when thermostat senses a sufficient increase in firebox temperature. Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before blower turns on. After heater modulates to pilot position, blower will continue to run. Blower will shut off after firebox temperature decreases. Note: It is safe to operate fireplace with blower turned off. However, blower helps distribute heated air from fireplace.

OFF

Figure 30 - Auto/Off/On Switch

Auto/Off/On Switch

Page 22 of the FMI VMH26TNC user manual — Inspecting Burner
Page 22 · click to enlarge
Page 22

Inspecting Burner

Check pilot flame pattern and burner flame pattern often.

  • BURNER FLAME PATTERN Figure 33 shows a correct burner flame pattern. Figure 34 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge. Note: When using fireplace for the first time, flame will be orange for approximately 1 hour until log cures. If burner flame pattern is incorrect, as shown in Figure 34
  • turn fireplace off (see To Turn Off Gas to Appliance , page 21)
  • see Troubleshooting , page 24
  • PILOT FLAME PATTERN Figure 31 shows a correct pilot flame pattern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. This will cause thermocouple to cool. When thermocouple cools, the fireplace will shut down. If pilot flame pattern is incorrect, as shown in Figure 32
  • turn fireplace off (see To Turn Off Gas to Appliance, page 21)
  • see Troubleshooting , page 24 Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.
FMI VMH26TNC — Inspecting Burner diagram (page 22)
Fig. 20 · Inspecting Burner

Figure 31 - Correct Pilot Flame Pattern

Figure 34 - Incorrect Burner Flame

Figure 32 - Incorrect Pilot Flame Pattern

Show 6 more labels / short text on this page
Thermocouple Pilot Burner · (Propane/LP Shown) · Pilot Burner · Thermocouple · Pattern · (Propane/LP Shown)
Page 23 of the FMI VMH26TNC user manual — CABINET
Page 23 · click to enlarge
Page 23

Cleaning and Maintenance

4. Check injector holder located at end of burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into primary air holes on injector holder. 6. In case any large clumps of dust have now been pushed into burner repeat steps 3 and 4. Clean pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in pilot assembly. There is a small pilot air inlet hole about 2" from where pilot flame comes out of pilot assembly (see Figure 36). With unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner Injector Holder and Pilot Air Inlet Hole The primary air inlet holes allow proper amounts of air to mix with gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every 3 months during operation and have heater inspected yearly by a qualified service person. We also recommend that you keep burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could dam- age the pilot assembly. 1. Shut off unit, including pilot. Allow unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 35). 3. Blow air through ports/slots and holes in burner.

Primary Air Inlet Holes

Figure 35 - Injector Holder On Outlet

Pilot Air Inlet Hole

Figure 36 - Pilot Inlet Air Hole

CABINET

Air Passageways Use a vacuum cleaner or pressurized air to clean.

Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe cabinet to remove dust.

Show 6 more labels / short text on this page
Ports/Slots · Injector Holder · Burner Tube · Burner Tube · Pilot Assembly · (Propane/LP Shown)
Page 24 of the FMI VMH26TNC user manual — OBSERVED PROBLEM
Page 24 · click to enlarge
Page 24

Troubleshooting

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor cable pinched or wet
1. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 2. Reconnect ignitor cable
2. Ignitor electrode not connected to ignitor cable 3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong
3. Replace ignitor cable 4. Replace piezo ignitor 5. Replace pilot assembly 6. Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve
2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance, page 23) or replace ODS/ pilot assembly 7. Replace gas regulator
5. Depleted gas supply (propane/LP only) 6. ODS/pilot is clogged
7. Gas regulator setting is not correct
Page 25 of the FMI VMH26TNC user manual — OBSERVED PROBLEM
Page 25 · click to enlarge
Page 25

Troubleshooting

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation 4. Fully open equipment shutoff valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local propane/LP or natural gas company B) Clean ODS/pilot (see Cleaning and Maintenance , page 23) or replace ODS/ pilot assembly
3. Safety interlock system has been triggered 4. Equipment shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 7. Thermocouple damaged 8. Control valve damaged
7. Replace pilot assembly 8. Replace control valve

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice 2. Contact local propane/LP or natural gas company
2. Inlet gas pressure too low

Delayed ignition of burner

1. Manifold pressure too low
1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice
2. Burner orifice is clogged

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice 2. Replace burner pressure 3. Contact local propane/LP or natural gas company 4. Replace gas regulator
2. Burner damaged 3. Low inlet gas pressure
4. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 23) 2. Replace gas regulator
2. Gas regulator defective
Page 26 of the FMI VMH26TNC user manual — OBSERVED PROBLEM
Page 26 · click to enlarge
Page 26

Troubleshooting

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Slight smoke or odor during initial operation

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Fireplace produces a whis- tling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP gas company 3. Observe minimum installation clearances (see pages 9 through 12) 4. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice
3. Air passageways on fireplace blocked
4. Dirty or partially clogged burner orifice

White powder residue form- ing within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Fireplace produces a click- ing/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is normal with most fireplaces. If noise is excessive, contact qualified service person
Page 27 of the FMI VMH26TNC user manual — OBSERVED PROBLEM
Page 27 · click to enlarge
Page 27

Troubleshooting

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwant- ed odors

1. Fireplace burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above) 2. Low fuel supply (propane/ LP) 3. Gas leak. See Warning statement above
1. Ventilate room. Stop using odor causing products while fireplace is running
2. Refill supply tank
3. Locate and correct all leaks (see Checking Gas Connections , page 18)

Fireplace shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local propane/LP or natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 23)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement above
1. Locate and correct all leaks (see Checking Gas Connections , page 18) 2. Replace control valve
2. Control valve defective

Gas odor during combus- tion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement above
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 18)

Moisture/condensation no- ticed on windows

1. Not enough combustion/ ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 6)
Page 28 of the FMI VMH26TNC user manual — Service Hints
Page 28 · click to enlarge
Page 28

Specifications

  • VMH26TPC
  • Rating (Variable): 14,000/26,000 Btu/Hr
  • Gas Type: Propane/LP Gas Only
  • Ignition: Piezo
  • Pressure Regulator Setting: 8" W.C.
  • Inlet Gas Pressure (in. of water): Maximum - 14" W.C., Minimum* - 11" W.C. * For purposes of input adjustment
  • VMH26TNC
  • Rating (Variable): 14,000/26,000 Btu/Hr
  • Gas Type: Natural Gas Only
  • Ignition: Piezo
  • Pressure Regulator Setting: 3" W.C.
  • Inlet Gas Pressure (in. of water): Maximum - 10.5" W.C., Minimum* - 5" W.C. * For purposes of input adjustment
  • For Both Models
  • Dimensions (H x W x D) (including hood and screws): Fireplace - 25 7 / 8 " x 26 13 / 16 " x 9 3 / 8 ", Carton - 32 5 / 8 " x 27 3 / 16 " x 11 5 / 8 "
  • Weight: Fireplace - 44.5 lbs., Shipping - 48 lbs.

Service Hints

Replacement Parts Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burner will have delayed ignition
  • fireplace will not produce specified heat
  • propane/LP gas supply may be low (propane/LP only) You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.
  • Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537. When calling, have ready:
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • purchase date Usually, we will ask you to return the part to the factory.

Technical Service You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready. You can also visit our web site at www.fmiproducts.com.

Page 29 of the FMI VMH26TNC user manual — Accessories
Page 29 · click to enlarge
Page 29

Accessories

CORNER MANTEL WITH Full HEARTH BASE C26TU - Unfinished, Traditional Design C26TO - Oak Finished, Traditional Design C26GO - Oak Finished, Georgian Design For all models. Space-saving mantel and hearth base corner design features clean, classic lines. Available in a stained oak, fin- ish or an unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided perimeter trim kit is sold separately.

Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the ad- dress listed on the back page of this manual.

Perimeter TRIM KIT GAB6094 - Black GAP6094 - Platinum For all models. Optional three-sided perim- eter trim kit for recessed installations (when unit is on the floor) or in mantel. Provides a finished appearance by covering rough edges of wall/mantel opening.

Wall MANTEL and full hearth base W26TU - Unfinished, Traditional Design W26TO - Oak Finished, Traditional Design W26GO - Oak Finished, Georgian Design For all models. Mantel features clean, classic lines. Available in a stained oak or unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided perimeter trim kit is sold separately.

Extruded Louver Kit GAP9092 - Platinum For all models. Optional extruded louver. Kit contains 2 louvers.

THERMOSTATICALLY - CON- TROLLED BLOWER KIT GA3450TA For all models. Provides better heat distribu- tion. Makes fireplace more efficient. Automati- cally turns off and on as needed.

Page 30 of the FMI VMH26TNC user manual — Models vmh26tpC (Shown) and vmh26tnC
Page 30 · click to enlarge
Page 30

Parts

Models vmh26tpC (Shown) and vmh26tnC

FMI VMH26TNC — Models vmh26tpC (Shown) and vmh26tnC diagram (page 30)
Fig. 21 · Models vmh26tpC (Shown) and vmh26tnC
Page 31 of the FMI VMH26TNC user manual — VMH26TPC
Page 31 · click to enlarge
Page 31

PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.

VMH26TPC

VMH26TNC

  • KEY NO. PART NO. DESCRIPTION QTY 1 102633-02 Outer Casing Top
  • 1 2 102624-02 Outer Casing
  • 1 3 099230-02 Shoulder Screw
  • 14 4 098304-01 Screw, #10 x 3/8"
  • 15 5 109824-05 Burner
  • 1 6 103209-09 Louvered Door
  • 2 7 102635-02 Left and Right Side Front
  • 2 8 111421-01 Bushing
  • 1 9 M10908-75 Hex Washer Head Tapping Screw
  • 1 10 104281-02 Firebox Hood
  • 1 11 102638-01 Firebox Top
  • 1 12 PP224 ODS/Pilot Assembly
  • 1 PP229 ODS/Pilot Assembly
  • 1 13 ** Firebox Wrapper
  • 1 14 099211-01 Control Bracket Screw
  • 2 15 103963-01 Inlet Tube
  • 1 16 102834-01 Burner Tube
  • 1 17 098304-02 Black Screw, #6 x 3/8
  • 4 18 098303-02 Regulator Screw
  • 2 19 ** Outer Shell Base
  • 1 20 102649-02 Branch Support
  • 1 21 099415-09 Gas Regulator
  • 1 099415-10 Gas Regulator
  • 1 22 102875-01 Regulator Bracket
  • 1 23 101381-01 Valve Cover and Piezo
  • 1 24 099387-11 Pilot Tube
  • 1 25 098271-06 Ignitor Cable
  • 1 26 107186-01 Injector
  • 1 107186-02 Injector
  • 1 27 101006-02 Pilot Bracket
  • 1 28 098249-01 Nut, M5
  • 2 29 098522-26 Gas Valve
  • 1 098522-23 Gas Valve
  • 1 30 102639-01 Baffle
  • 1 31 101628-01 Flexible Connector
  • 1 32 102869-01 Control Bracket
  • 1 33 102731-01 Control Shield
  • 1 34 103295-05 Screen Assembly
  • 1 35 107048-01 Log Set Kit
  • 1 36 104313-01 Right Hinge
  • 1 37 104313-02 Left Hinge
  • 1 38 M10908-2 Hinge Screws
  • 4 39 103734-01 Burner Support
  • 2 40 M11084-26 Hex Head Screw, #10 x 3/8"
  • 28 41 097809-03 3/8 NPT x 3/8" Flare Brass Fitting
  • 1 42 101629-01 Bushing
  • 1 43 107634-02 NG Data Plate
  • 1 PARTS AVAILABLE - NOT SHOWN 101054-01 Lighting Instruction Plate
  • 1 100563-01 Warning Plate
  • 1 103470-01 Hardware Package
  • 1 ** Not a field replacement part
Page 32 of the FMI VMH26TNC user manual — FMI PRODUCTS, LLC LIMITED WARRANTIES
Page 32 · click to enlarge
Page 32

Warranty

KEEP THIS WARRANTY

Model (located on product or identification tag)

Serial No. (located on product or identification tag)

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow- ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.

Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).

This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.

FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For information about this warranty contact:

2701 S. Harbor Blvd. Santa Ana, CA 92704

113111-01 Rev. K 05/10

Date Purchased

Ask about the FMI VMH26TNC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI VMH26TNC

Be the first to ask — other owners or our team will answer.

Original document

FMI VMH26TNC manual PDF

32 pages·1.5 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…