B-VENT DECORATIVE ELECTRONIC IGNITION GAS FIREPLACEp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1PFS ®p.1US Cp.1NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATIONp.2TABLE OF CONTENTSp.2Safetyp.3DANGER: Carbon monoxide poisoning may lead to death!p.3Introductionp.5CORNER INSTALLATIONp.5INTERNAL WALL INSTALLATIONp.5FLUSH INSTALLATIONp.5FULL PROJECTION INSTALLATIONp.5Product Specificationsp.6PreInstallation Preparationp.7Venting Installationp.9EXAMPLE 3 EXAMPLE 2 EXAMPLE 1p.10Figure 12 - Checking for Spillage Installationp.11Installationp.12GAS LINE HOOK-UPp.12Installing optional GLASS DOOR Accessoryp.16VENT DAMPER MUST BE LOCKEDp.17CLOSE OPENp.17Operationp.18FOR YOUR SAFETY READ BEFORE LIGHTINGp.18LIGHTING INSTRUCTIONSp.18TO TURN OFF GASp.19OPTIONAL REMOTEp.19Inspecting Burnersp.19Cleaning and Maintenancep.20Replacement Partsp.20Wiring Diagramp.21INCOMING MAIN GASp.21WALL SWITCHp.21(NOT SUPPLIED)p.21SUPPLYp.21ONp.21OFFp.21BLACKp.21120V AC INCOMINGp.21IGNp.21WHITEp.21VENT SAFETY SHUTOFF SWITCH MANUAL DAMPERp.21MODEL SP745 IGNITION CONTROLp.21GREENp.21OR BREAKER) (FUSE BOXp.21PV GND PV/MV TR MV THp.21EV1p.21SWITCHp.21ELECTRICAL RATING:p.21EV2p.2124V ACp.21STEP DOWN TRANSFORMERp.21120V ACp.21OPTIONAL REMOTE CONTROLp.21TO GAS LINEp.21BURNERp.21OBSERVED PROBLEMp.22POSSIBLE CAUSEp.22REMEDYp.22TROUBLESHOOTINGp.23Partsp.24M36E(P)(B,H) VM36E(P)(B,H)p.25M36(B,H) VM36(B,H)p.26Logsets for models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H)p.27Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H)p.28NOTESp.30Warrantyp.32KEEP THIS WARRANTYp.32FMI PRODUCTS, LLC LIMITED WARRANTIESp.32
Page 1 of the FMI VM36E(B,H) user manual — B-VENT DECORATIVE ELECTRONIC IGNITION GAS FIREPLACE
Page 1 · click to enlarge
Page 1

B-VENT DECORATIVE ELECTRONIC IGNITION GAS FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

US C

m36e(b,h), m42e(b,h), VM36E(B,h) and vm42E(b,h)

m36eP(b,h), m42eP(b,h), VM36EP(B,h) and vm42EP(b,h)

FOR YOUR SAFETY — Do not store or use gasoline or any other flammable

vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :

  • Do not try to light any appliance.
  • Do not touch any electrical switch;
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Natural Gas models · PROPANE/LP Gas models

Page 2 of the FMI VM36E(B,H) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

B-VENT DECORATIVE ELECTRONIC IGNITION GAS FIREPLACEp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1PFS ®p.1US Cp.1NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATIONp.2TABLE OF CONTENTSp.2Safetyp.3DANGER: Carbon monoxide poisoning may lead to death!p.3Introductionp.5CORNER INSTALLATIONp.5INTERNAL WALL INSTALLATIONp.5FLUSH INSTALLATIONp.5FULL PROJECTION INSTALLATIONp.5Product Specificationsp.6PreInstallation Preparationp.7Venting Installationp.9EXAMPLE 3 EXAMPLE 2 EXAMPLE 1p.10Figure 12 - Checking for Spillage Installationp.11Installationp.12GAS LINE HOOK-UPp.12Installing optional GLASS DOOR Accessoryp.16VENT DAMPER MUST BE LOCKEDp.17CLOSE OPENp.17Operationp.18FOR YOUR SAFETY READ BEFORE LIGHTINGp.18LIGHTING INSTRUCTIONSp.18TO TURN OFF GASp.19OPTIONAL REMOTEp.19Inspecting Burnersp.19Cleaning and Maintenancep.20Replacement Partsp.20Wiring Diagramp.21INCOMING MAIN GASp.21WALL SWITCHp.21(NOT SUPPLIED)p.21SUPPLYp.21ONp.21OFFp.21BLACKp.21120V AC INCOMINGp.21IGNp.21WHITEp.21VENT SAFETY SHUTOFF SWITCH MANUAL DAMPERp.21MODEL SP745 IGNITION CONTROLp.21GREENp.21OR BREAKER) (FUSE BOXp.21PV GND PV/MV TR MV THp.21EV1p.21SWITCHp.21ELECTRICAL RATING:p.21EV2p.2124V ACp.21STEP DOWN TRANSFORMERp.21120V ACp.21OPTIONAL REMOTE CONTROLp.21TO GAS LINEp.21BURNERp.21OBSERVED PROBLEMp.22POSSIBLE CAUSEp.22REMEDYp.22TROUBLESHOOTINGp.23Partsp.24M36E(P)(B,H) VM36E(P)(B,H)p.25M36(B,H) VM36(B,H)p.26Logsets for models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H)p.27Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H)p.28NOTESp.30Warrantyp.32KEEP THIS WARRANTYp.32FMI PRODUCTS, LLC LIMITED WARRANTIESp.32
Page 3 of the FMI VM36E(B,H) user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 3 · click to enlarge
Page 3

Safety

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas sup plier's instructions
  • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace
  • in a recreational vehicle
  • where curtains, furniture, clothing or other flammable objects are less than 36" from front and 42" from top of fireplace. For side clearances see Figure 6, page 7
  • in high traffic areas
  • in windy or drafty areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni tion. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. 7. A hearth extension is not required with this appliance. If one is installed, it is for aes thetic purposes only and does not have to meet the standard requirements. 8. Turn fireplace off and let cool before ser vicing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a qualified service person. 9. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance , page 20.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ ence of alcohol and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

Page 4 of the FMI VM36E(B,H) user manual — Safety
Page 4 · click to enlarge
Page 4

Safety

11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire place nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide

adequate clearances around air open ings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpet ing, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchang er insert or other accessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings.

  • Unpacking The following items are packed inside the firebox. Remove before positioning firebox into framing.
  • Transition Collar - For vent connection
  • Ceramic Log Pack - Shrink-wrapped on cardboard
  • Three (3) plastic bags containing lava rock, pan and ember materials
  • Rear Log - Remove two plastic quick ties from around burner and grate
  • Grate Stand - Lift off of burner pan Check all items for any shipping damage. If damaged, promptly inform dealer or distributor where you bought the product. Safely retain these items for later installation.

Introduction Models M36E(P)(B,H), VM36E(P)(B,H), M42E(P)(B,H) and VM42E(P)(B,H) are vented gas fireplaces that use an electronic control valve and electronic ignition system. A 6" B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 9 and 10.

BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This FMI PRODUCTS, LLC appliance and its approved components are safe when installed according to this installation manual and are op erated as recommended by FMI PRODUCTS, LLC. Unless you use FMI PRODUCTS, LLC approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions: A) Modification of the appliance or any of the

Models M36E(B,H), VM36E(B,H), M42E(B,H) and VM42E(B,H) are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. A respec tive model PCBE-36 or PCBE-42 conversion kit may be purchased for simple conversion to propane/LP gas. See Accessories, page 29.

components. B) Use of any component part not approved

by FMI PRODUCTS, LLC in combination with this appliance. C) Installation and/or operation in a manner

other than instructed in this manual. D) The burning of anything other than the type of

gas approved for use in this gas appliance.

Page 5 of the FMI VM36E(B,H) user manual — CORNER INSTALLATION
Page 5 · click to enlarge
Page 5

Introduction

The installation must conform with local codes or, in the absence of local codes, with the cur rent National Fuel Gas Code, ANSI Z223.1/ NFPA 54. This appliance complies with ANSI Z21.50/CSA 2.22.

The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.

Selecting Location To determine the safest and most efficient location for your appliance, you must take into consideration the following guidelines: 1. The location must allow for proper clear ances (see Clearances, page 7). 2. Consider a location where heat output would not be affected by drafts, air con ditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 1 shows a plan view of a few com mon locations. Flush installations are recommended where living space is limited or at a premium and since the space required to enclose the ap pliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions. Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference. Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.

CORNER INSTALLATION

INTERNAL WALL INSTALLATION

FLUSH INSTALLATION

FULL PROJECTION INSTALLATION

Figure 1 - Possible Locations for

Installing Appliance

Page 6 of the FMI VM36E(B,H) user manual — Product Specifications
Page 6 · click to enlarge
Page 6

Product Specifications

GAS RATING - NATURAL M36E(B,H), VM36E(B,H) M42E(B,H), VM42E(B,H) Max. Input Rating:40,000 Btu/Hr45,000 Btu/Hr Manifold Pressure:3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure:4.5" WC (1.12 kPa) 4.5" WC (1.12 kPa) Maximum Supply Pressure:10.5" WC (2.66 kPa) 10.5" WC (2.66 kPa) Orifice Size:# 30# 29 GAS RATING - PROPANE/LP M36P(B,H), VM36P(B,H) M42P(B,H), VM42P(B,H) Max. Input Rating:40,000 Btu/Hr45,000 Btu/Hr Manifold Pressure:10" WC (2.49 kPa) 10" WC (2.49 kPa) Minimum Supply Pressure:11" WC (2.74 kPa) 11" WC (2.74 kPa) Maximum Supply Pressure:13" WC (3.23 kPa) 13" WC (3.23 kPa) Orifice Size:# 52# 50
FMI VM36E(B,H) — Product Specifications diagram (page 6)
Fig. 1 · Product Specifications

For Use With 6"Ø Type B-1 Vent Pipe Only

Model 36Model 42Model 36 Model42 Model 36 Model 42 A 29"36"I 40 1/4" 44 1/4" Q 13 7/8" 14" B 5/8"5/8"J 21" 24"R 10 1/2" 12 1/2" C 41"48"K 8" 9"S 2 1/2" 2 1/2" D 12"14"L 34 3/4" 42"T 8 1/8" 8 1/8" E 211/4"23"M 42" 49"U 11" 12 3/4" F 221/4" (24" w/o Brick)29 1/4" (31" w/o Brick)N 36" 40"V 7" 7" G 325/8" (34" w/o Brick)39 1/2" (41 1/4" w/o Brick) O 37" 41"W 2 1/4" 2 1/4" H 153/4" (16 3/4" w/o Brick)17 3/4" (18 3/4" w/o Brick) P 8 5/8" 10 1/2" X 5" 4 1/2"

Figure 2 - Appliance Dimensions

Page 7 of the FMI VM36E(B,H) user manual — PreInstallation Preparation
Page 7 · click to enlarge
Page 7

PreInstallation Preparation

CLEARANCES Minimum clearances to combustibles are: Back and Sides of Outer Surround 0" min. Drywall to Sides of Front Face (Nailing Flanges) 0" min. “B” Vent Surfaces 1" min. Ceiling to Opening 42" min. Floor 0" min. Perpendicular Wall See Figure 6

MANTEL CLEARANCES and Wall Details A combustible mantle shelf maybe installed a maximum 12" (22.9 cm) from wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to fireplace opening.

FMI VM36E(B,H) — PreInstallation Preparation diagram (page 7)
Fig. 2 · PreInstallation Preparation
M36E(B,H), M36EP(B,H) VM36E(B,H), VM36EP(B,H)M42E(B,H), M42EP(B,H) VM42E(B,H), VM42EP(B,H) A14" (35.6 cm)15" (38 cm) B8" (20.3 cm)9" (22.9 cm)

Figure 5 - Mantel Clearances - Side View

Figure 3 - Minimum Clearances

FMI VM36E(B,H) — PreInstallation Preparation diagram (page 7)
Fig. 3 · PreInstallation Preparation

1" (2.5 cm) Min. Clearance to "B" Vent's Outer Pipe

FMI VM36E(B,H) — PreInstallation Preparation diagram (page 7)
Fig. 4 · PreInstallation Preparation

42" (106.7 cm) Min. Clearance from Opening to Ceiling 0" Clearance

Maintain 2" (5.1 cm) Min. Clearance to Transition Pipe as Measured at Outer Vent Collar

Required air spaces are indicated with an "*". Do not pack with insulation or any other material.

M36E(B,H), M36EP(B,H) VM36E(B,H), VM36EP(B,H)M42E(B,H), M42EP(B,H) VM42E(B,H), VM42EP(B,H) A9" (22.9 cm)6" (15.2 cm) B12" (30.5 cm)9" (22.9 cm)

Figure 4 - Minimum Clearances

Figure 6 - Side Clearances - Top View

Show 6 more labels / short text on this page
Front Face · Drywall · (Cross Section) · (Top View) · (Front View) · (Cross Section)
Page 8 of the FMI VM36E(B,H) user manual — A
Page 8 · click to enlarge
Page 8

PreInstallation Preparation

FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line enclosure, then all measurements must be from surface of covering. 2. Place appliance into framing and se cure. Note: If appliance is to be raised above floor level, a platform must be built to support appliance. 3. Install supply line to appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above bottom of appliance. The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance (see Figure 19, page 13). 4. Repack insulation around gas line to cover any remaining openings in conduit sleeve. Prepare incoming gas line with teflon tape or pipe joint compound and hook up incoming gas line to flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.

A

B

M36E(B,H), M36EP(B,H) VM36E(B,H), VM36EP(B,H)M42E(B,H), M42EP(B,H) VM42E(B,H), VM42EP(B,H) A 40 3/8" (102 cm) 44 3/8" (112 cm) B 21 3/8" (54.3 cm) 23 1/8" (58.7 cm) C 41 1/4" (104.8 cm) 48 1/4" (122.6 cm)

Figure 7 - Rough Opening for Installing

These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted

D

A

B

3/4" Clearance Not Required at Nailing Flanges

M36E(B,H), M36EP(B,H) VM36E(B,H), VM36EP(B,H)M4E2(B,H), M42EP(B,H) VM42E(B,H), VM42EP(B,H) A 24 1/2" (62.2 cm) 27 9/16" (70 cm) B 73 7/8" (187.6 cm) 83 7/8" (213 cm) C 52 3/16" (132.6 cm) 59 5/16" (150.6 cm) D 17 1/4" (43.8 cm) 19 1/2" (49.5 cm)

Figure 8 - Corner Installation Guidelines

in Wall

Page 9 of the FMI VM36E(B,H) user manual — Venting Installation
Page 9 · click to enlarge
Page 9

PreInstallation Preparation

Installing Transition Pipe and Starter Collar The transition pipe and starter collar shown in Figure 9 are supplied with fireplace, unat tached and ready for installation. Remove starter collar and set aside. Slide transition pipe over vent collar and attach with a mini mum of three screws. Replace starter collar over transition pipe and attach using four screws located on leg stands (five used on model M42E). To install B-vent piping, slide first piece of B-vent over transition pipe and attach with either a minimum of two screws or other means approved by the vent manu facturer.

Figure 9 - Installing Transition Pipe and

Venting Installation

A B-type venting system must be connected to appliance for venting to the outside of building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B- type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code ANSI Z223.1/NFPA 54. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance. This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chim ney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10, page 10 are typical of most B-vent installations and codes practices. Example 1: Shows the minimum allowable system height and lateral offset for a 60° or greater inclination. Code specifies that offsets at 60° or greater are considered horizontal and must follow the 75% rule for lateral to total vertical system height. Codes also al low only one offset in the total system when

at 60° or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows a multiple offset each at 45° of inclination. Multiple offsets are permit ted if they do not exceed 45° of inclination. The total lengths of the two offsets are not required to meet the 75% allowable rule. Example 3: Shows a single offset at 45° of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% rule. In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceil ing joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained. Vent terminations must be located in ac cordance with height and proximity rules of NFPA No. 54. These rules apply to vents at 12" diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 11, page 10).

Show 5 more labels / short text on this page
B-Vent Piping · Starter Collar · Transition Pipe · Vent Collar · Starter Collar
Page 10 of the FMI VM36E(B,H) user manual — EXAMPLE 3 EXAMPLE 2 EXAMPLE 1
Page 10 · click to enlarge
Page 10

Venting INSTALLATION

FMI VM36E(B,H) — Venting INSTALLATION diagram (page 10)
Fig. 5 · Venting INSTALLATION

EXAMPLE 3 EXAMPLE 2 EXAMPLE 1

Figure 10 - Typical B-Vent Configuration

If venting horizontally through a side wall be comes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing B-type vent systems if the system is at or above the recommended diameter of the flue, in this case 6". The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation. It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in ac cordance with the common venting guides Appendix G of the current National Fuel Gas Code ANSI Z223.1/NFPA 54. Note: Before connecting this appliance to an existing vent system or a common venting system consult with your local architect, plan ner or building official.

8 Ft. Min.

x Listed Gas Vent

Roof Pitch x/12 Listed Clearance

H (Min) Height From Roof

Roof PitchH (Min Feet.) Meter Flat to 6/121.00.30 6/12 to 7/121.250.38 Over 7/12 to 8/12 1.50.46 Over 8/12 to 9/12 2.00.61 Over 9/12 to 10/12 2.50.76 Over 10/12 to 11/12 3.250.99 Over 11/12 to 12/12 4.01.22 Over 12/12 to 14/12 5.01.52 Over 14/12 to 16/12 6.01.83 Over 16/12 to 18/12 7.02.13 Over 18/12 to 20/12 7.52.27 Over 20/12 to 21/12 8.02.44

Figure 11 - B-Vent Terminations

Listed Vent Cap · Lowest Discharge Opening · Listed Vent Cap

Page 11 of the FMI VM36E(B,H) user manual — Figure 12 - Checking for Spillage Installation
Page 11 · click to enlarge
Page 11

Venting INSTALLATION

CHECKING FOR PROPER VENTING After completing and checking electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of fire place opening and play it along entire length of opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance. If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.

FMI VM36E(B,H) — Venting INSTALLATION diagram (page 11)
Fig. 6 · Venting INSTALLATION

Check this area along entire top edge of fireplace opening. Smoke or flame should be drawn into appliance opening.

Figure 12 - Checking for Spillage Installation

WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace. Refer to wiring diagram in this manual on page 18. optional Remote control INSTALLATION (model WRC) Note: If using optional wireless hand-held remote control, wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. 1. Remove front refractory access panel by lifting up and angling out of firebox open ing (see Figure 13). 2. The WRC model receiver does not require a battery. Receiver can be installed by plugging the short extension cord into fireplace receptacle. Plug receiver unit into extension cord. Plug ignition module plug into receiver unit (see Figure 14).

FMI VM36E(B,H) — Figure 12 - Checking for Spillage Installation diagram (page 11)
Fig. 7 · Figure 12 - Checking for Spillage Installation
Page 12 of the FMI VM36E(B,H) user manual — A
Page 12 · click to enlarge
Page 12

Installation

3. Activate remote handset battery by re moving insulating tab on back of handset (see Figure 15). Battery is included preinstalled. 4. Once the battery is activated unit is ready to use. 5. Replace front refractory access panel.

FMI PRODUCTS, LLC recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 18) and into appliance. Once con nected through appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 19, page 13). Before connecting black iron gas line to inside of appliance a sediment trap must be included outside appliance between gas line and gas shutoff valve. It must extend down 3" beyond center of pipe. Prepare incoming black iron gas line with teflon tape or pipe joint com pound (Check with local building codes).

Battery Cover 12 Volt Battery

Pull to Remove Insulation Tab

Figure 15 - Installing Battery into Back of

GAS LINE HOOK-UP

Typical Exterior Wall Gas Shutoff Installation

Figure 16 - Manual Shutoff Valve

1/2" NPT Incoming Black

A

Alternate Gas Supply Through Sub-Floor

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 16. In conformance with local codes, route a 1/2" NPT gas line to appliance through hole in left side of firebox or sub-floor as shown in Figure 17.

M36E(B,H M36EP(B VM36E(B, VM36EP(B), M42E(B,H), ,H M42EP(B,H) H), VM42E(B,H), ,H) VM42EP(B,H) A8 5/8" (21.9cm) 10 1/2" (26.7 cm)

Figure 17 - Routing Incoming Gas Line

Incoming 1/2" Gas Line Permitted by Local Codes Sediment Trap (Not Supplied)

FMI VM36E(B,H) — A diagram (page 12)
Fig. 8

Figure 18 - Sediment Trap

Show 9 more labels / short text on this page
Back of Handset · Key · Shutoff Valve · Extension · Handset · Installation · Iron Gas Line · 7" · 7"
Page 13 of the FMI VM36E(B,H) user manual — Installation
Page 13 · click to enlarge
Page 13

Installation

Complete your gas installation by connect ing incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.

EMBER AND PAN MATERIAL placement 1. Open bag(s) of vermiculite and fill entire burner pan until burner tube is completely covered (see Figure 20). 2. Smooth pan material just even with edges of burner pan. 3. Remove ember material from bag and flatten small amounts into quarter size pieces and lay on top of surface of pan material (see Figure 21). 4. Place just enough to cover entire surface and leave about a 1/2" gap under lower grate members to allow air to flow (see Figure 22, page 14).

WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that gas valve is on, apply a commercial leak detection solution to all con nections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Flexible Gas Line Do NOT Kink

Red Surface Indicates For Propane/LP Use Only

FMI VM36E(B,H) — Installation diagram (page 13)
Fig. 9 · Installation

Figure 19 - Connecting Flexible Gas Line to Millivolt Valve

FMI VM36E(B,H) — Installation diagram (page 13)
Fig. 10 · Installation

Vermiculite (Pan Material) Grate

FMI VM36E(B,H) — Installation diagram (page 13)
Fig. 11 · Installation

Figure 20 - Fill Entire Burner Pan with

Figure 21 - Ember Material on Surface of

Show 4 more labels / short text on this page
Gas Shutoff Valve · Inlet Pressure Tap · Vermiculite · Pan Material (Vermiculite)
Page 14 of the FMI VM36E(B,H) user manual — Installation
Page 14 · click to enlarge
Page 14

Installation

FMI VM36E(B,H) — Installation diagram (page 14)
Fig. 12 · Installation

Pan and Ember Material

FMI VM36E(B,H) — Installation diagram (page 14)
Fig. 13 · Installation

0.5"

Figure 22 - Pan and Ember Material

LOG PLACEMENT For Models M36E, M36EP, VME36 and VM36EP 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23. 3. Place log 3 into notch on log 2, resting front end on top of log 1 (see Figure 24). 4. Place upper end of log 4 into notch on log 2 as shown in Figure 24. Rest lower end of log 4 onto middle grate finger as shown in Figure 25. 5. Place upper end of log 5 into notch on left of log 2 (see Figure 25). Rest lower end of log 5 on grate as shown in Figure 26. 6. Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26. As an option to enhance the look of the hearth, you may place lava rock provided around front and sides of burner.

Figure 24 - Installing Logs 3 and 4

FMI VM36E(B,H) — Installation diagram (page 14)
Fig. 14 · Installation
FMI VM36E(B,H) — Installation diagram (page 14)
Fig. 15 · Installation

Figure 26 - Logs Installed for M36, M36P,

Figure 23 - Installing Logs 1 and 2

VM36 and VM36P Models

Show 5 more labels / short text on this page
Clearances · Log 6 · Log 4 · Notch · Log 1
Page 15 of the FMI VM36E(B,H) user manual — Installation
Page 15 · click to enlarge
Page 15

Installation

LOG PLACEMENT For Models M42E, M42EP, VME42 and VM42EP 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 27). 2. Insert lower end of log 2A between first two grate fingers and position upper end into notch on front of log 1. See Figure 27. Place log 2B on front right side of grate as shown in Figure 27. 3. Place log 3 into notch on top left of log 1, resting lower end on left two grate fingers (see Figure 28). 4. Place upper end of log 4 into notch on log 1 as shown in Figure 28. Rest lower end of log 4 on the middle grate finger as shown in Figure 29.

5. Place upper end of log 5 into notch on top inner right of log 1 (see Figure 29). Rest lower end of log 5 on middle grate finger as shown in Figure 30. 6. Place log 6 into notch on top right of log 1 (see Figure 29). Rest lower end of log 6 on top of log 2B (see Figure 30). As an option to enhance the look of the hearth, you may place lava rock provided around front and sides of burner pan.

FMI VM36E(B,H) — Installation diagram (page 15)
Fig. 16 · Installation
FMI VM36E(B,H) — Installation diagram (page 15)
Fig. 17 · Installation

Figure 27 - Installing Logs 1, 2A and 2B

Figure 29 - Installing Logs 5 and 6

FMI VM36E(B,H) — Installation diagram (page 15)
Fig. 18 · Installation
FMI VM36E(B,H) — Installation diagram (page 15)
Fig. 19 · Installation

Figure 30 - Logs Installed for M42E, M42EP, VM42E and VM42EP Models

Figure 28 - Installing Logs 3 and 4

Show 4 more labels / short text on this page
Notch · Log 1 · Log 2A · Log 2B
Page 16 of the FMI VM36E(B,H) user manual — Installing optional GLASS DOOR Accessory
Page 16 · click to enlarge
Page 16

Installation

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate damper door for outside air inlet will be located inside left “screen pocket” of firebox (see Figure 31). Pull handle to open or push to close.

Installing optional GLASS DOOR Accessory

Note: Glass door may be heavy for some individuals. If this is the case, please request help if needed. The M36E, VM36E, M42E and VM42E B- vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 29). Glass panels may be ordered and installed anytime after fireplace installation is complete. Follow these steps to install left and right panels: 1. With handle at the bottom, completely fold panel on its hinges. 2. With handle facing center of firebox open ing, insert lower pivot pin on glass door panel into hole in pivot plate on bottom edge of fireplace opening (see Figure 33). 3. Keeping folded door tilted, slide upper two pins into guide track found under upper facial edge of firebox opening. 4. Tilt glass assembly fully vertical until outer pivot pin snaps into mounting hole in up per spring clip (see Figure 33). 5. Once top and bottom pins are secured, unfold door into the closed position.

Figure 31 - Air Kit Handle Location

APPLIANCE ENCLOSURE Before finishing enclosure around appliance, inspect all joints around outer surround. Any gaps between nailing flanges and framing should be sealed with noncombustible insula tion or caulking. If appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will pre vent entry of cold air by means of conduction through the total bottom of appliance (see Figure 32).

Spring Clip Insert Pin Into Spring Clip

Slide Top Pin Into Door Track

Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position

Caulk Here Pack Insulation

Figure 32 - Sealing Between Appliance

Figure 33 - Installing Optional Glass

Show 7 more labels / short text on this page
Screen Pocket · Air Kit Handle · Side Framing · Side Framing · Pivot Plate · and Framing · Door
Page 17 of the FMI VM36E(B,H) user manual — VENT DAMPER MUST BE LOCKED
Page 17 · click to enlarge
Page 17

Installation

6. Repeat process for opposite door as sembly. 7. To adjust doors, slide them partially open. Using a screwdriver, loosen hold-down screws in the spring clip (see Figure 34) and pivot plate. 8. Close both doors until evenly joined at the middle and note gap at outer edges of face. 9. Reopen one door at a time and retighten upper and lower hold-down screws. 10. Repeat process until both doors are even ly joined, spaced and working freely.

Figure 34 - Adjusting Glass Doors

Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track

Press Spring Clip to Release Pivot Pin

The doors may be removed for replacement or cleaning as follows: 1. Partially open door and press up on upper spring clip with a screw driver until outer top pivot pin is free of clip. 2. Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail (see Figure 35).

Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track

Figure 35 - Removing Glass Doors

Opening Vent Damper Vent damper must be locked in the full open position before operating fireplace. If vent damper is not open, fireplace will not light.

VENT DAMPER MUST BE LOCKED

CLOSE OPEN

IN THE FULL OPEN POSITION TO OPERATE THE APPLIANCE

Figure 36 - Opening Vent Damper

Show 6 more labels / short text on this page
Spring Clip · Hold-Down Screw · Side Front Face · Partially Opened Door · Spring Clip · Pivot Plate
Page 18 of the FMI VM36E(B,H) user manual — LIGHTING INSTRUCTIONS
Page 18 · click to enlarge
Page 18

Operation

FOR YOUR SAFETY READ BEFORE LIGHTING

  • 1. STOP! Read the safety information, in column 1. 2. Turn off all electric power to appliance. 3. Turn wall switch to the OFF position. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel. 6. Turn equipment shutoff valve clockwise to the OFF position (see Figure 37). Do not force. 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, above. If you don’t smell gas, go to the next step. 8. Turn equipment shutoff valve counter clockwise to the ON position. Do not force. 9. Replace front refractory brick access panel. 10. Fully close glass doors if installed. 11. Turn on all electric power to appliance. 12. Turn wall switch to the ON position. 13. Visually locate pilot. The ignitor should begin to spark and main burner should ignite once flame appears at pilot.
  • If lighting appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners.
  • If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance , page 19, and call your service technician or gas supplier.

A. This appliance has a pilot which must

be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around

  • the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn

the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a quali fied service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part

has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

Figure 37 - Turning Equipment Shutoff

Valve to the OFF Position

Equipment Shutoff Valve · Adjustment Screw

Page 19 of the FMI VM36E(B,H) user manual — Inspecting Burners
Page 19 · click to enlarge
Page 19

Operation

TO TURN OFF GAS

1. Turn equipment shutoff valve to ON posi tion. You can now turn burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press ON/OFF buttons on hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press the ON/OFF button to turn burner on and off.

TO APPLIANCE 1. Turn off wall switch. 2. Turn off all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn gas control knob clockwise to OFF. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.

FMI VM36E(B,H) — TO TURN OFF GAS diagram (page 19)
Fig. 20

OPTIONAL REMOTE

OPERATION Note: The WRC receiver and hand-held re mote control kit must be purchased separately (see Accessories, page 29). Follow installa tion instructions on page 10.

Figure 38 - Pilot

Inspecting Burners

Check pilot flame pattern and burner flame patterns often.

  • Figure 40 shows a typical flame pattern. If burner flame pattern differs from that de scribed:
  • turn appliance off (see To Turn Off Gas to Appliance )
  • see Troubleshooting , page 22
  • PILOT Assembly The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner. The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem. If your pilot assembly does not meet these requirements:
  • Turn adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 37, page 19). Do not remove adjust ment screw.
  • see Troubleshooting , page 22
FMI VM36E(B,H) — Inspecting Burners diagram (page 19)
Fig. 21 · Inspecting Burners

Figure 39 - Correct Pilot Flame Pattern

FMI VM36E(B,H) — Inspecting Burners diagram (page 19)
Fig. 22 · Inspecting Burners

BURNER FLAME PATTERN Burner flames will be steady, not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of pan or sides of logset.

Figure 40 - Typical Flame Pattern

Ignitor · Sensing Rod · Ignitor/ Sensor

Page 20 of the FMI VM36E(B,H) user manual — Replacement Parts
Page 20 · click to enlarge
Page 20

Cleaning and Maintenance

WARNING: Installation and repair should be done by a quali fied service person. The appli ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys tem be kept clean.

  • pilot and burner
  • Remove logs and ember material before cleaning burner and replace when cleaning is complete.
  • Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.
  • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.
  • logs
  • If you remove logs for cleaning, refer to log placement information on page 12 to properly replace logs.
  • Use a vacuum cleaner to remove any carbon buildup on logs.
  • Replace log(s) if broken. See Replacement Parts .
  • Replace ember material periodically as needed. See Replacement Parts .

Replacement Parts

  • When calling, have ready:
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • purchase date Usually, we will ask you to return the part to the factory.

Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866- 328-4537.

Page 21 of the FMI VM36E(B,H) user manual — EV2
Page 21 · click to enlarge
Page 21

Wiring Diagram

INCOMING MAIN GAS

WALL SWITCH

(NOT SUPPLIED)

SUPPLY

ON

OFF

BLACK

120V AC INCOMING

IGN

WHITE

VENT SAFETY SHUTOFF SWITCH MANUAL DAMPER

MODEL SP745 IGNITION CONTROL

GREEN

OR BREAKER) (FUSE BOX

PV GND PV/MV TR MV TH

EV1

BLACK

GREEN

SWITCH

WHITE

ELECTRICAL RATING:

120v, 60Hz, 0.7A

EV2

24V AC

STEP DOWN TRANSFORMER

120V AC

OPTIONAL REMOTE CONTROL

TO GAS LINE

BURNER

  • Service Hints When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burner will have delayed ignition
  • fireplace will not produce specified heat
  • propane/LP gas supply may be low if using propane/LP gas If using propane/LP gas, you may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

Technical Service You may have further questions about instal lation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328- 4537. When calling please have your model and serial numbers of your heater ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.

Pilot Burner · Pilot Gas Line · Robertshaw

Page 22 of the FMI VM36E(B,H) user manual — OBSERVED PROBLEM
Page 22 · click to enlarge
Page 22

Troubleshooting Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1. No gas supply or shutoff valve is OFF

1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (re fer to Replacement Parts, page 20) 7. Check that main power is on and that all wire connec tions are made correctly to ignition model (see Wiring Diagram, page 21). Check for 24 VAC at the secondary side of transformer. If 24 VAC is present and module does not operate, have module replaced otherwise have transformer replaced 8. Open vent damper until fully locked in OPEN position

2. Air in gas line
3. Construction debris clog ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve knob is not opening
7. No power to unit or the ignition module or power transformer is bad
8. Vent damper not fully open

Pilot will not stay lit

1. Loose wiring on ignitor wire to ignition module and/or poor ground to igni tion module 2. Pilot flame too low to sense
1. Check wiring connection. Re fer to wiring diagram, page 21, and/or check ground wire to ignition module 2. Clean and adjust pilot burn er and check gas supply and inlet pressure to unit Note: Have a qualified tech nician replace pilot assem bly if broken or corroded

No gas to burner, although wall switch and valve are set to the ON position

1. Wall switch wires defective or too long 2. Thermopile not generating sufficient voltage
1. Check electrical connec tions 2. Recheck problems 1 and 2
Page 23 of the FMI VM36E(B,H) user manual — POSSIBLE CAUSE
Page 23 · click to enlarge
Page 23

TROUBLESHOOTING

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Fol low the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is normal with most fireplaces. If noise is ex cessive, contact qualified service person

Fireplace produces unwanted odors

1. Fireplace burning vapors from paint, hair spray, glues, etc. (See IMPOR TANT statement above) 2. For propane/LP gas, low fuel supply 3. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop us ing odor causing products while fireplace is running
2. Contact local propane/LP supplier 3. Locate and correct all leaks (see Gas Line Hook-Up , page 12)

Gas odor even when gas control valve is off

1. Gas leak. See Warning statement at top of page
1. Locate and correct all leaks (see Gas Line Hook-Up , page 12) 2. Replace control valve
2. Control valve defective

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Gas Line Hook-Up , page 12)

Dark residue on logs or inside of fireplace

1. Improper log placement
1. Properly locate logs (see log placement sections on page 12) 2. Clean out air holes at burn er inlets. Periodically repeat as needed 3. Remove blockage or re place burner 4. Have vent system inspect ed, including termination cap. Remove any restric tions or obstruction 5. Clear excess embers until a minimum gap of 1/2" remains under grate
2. Air holes at burner inlet blocked
3. B u r n e r f l a m e h o l e s blocked 4. Improper venting or exces sive blockage
5. Excessive amounts of em bers and pan material
Page 24 of the FMI VM36E(B,H) user manual — Models M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H), VM36E(B,H), VM36EP(B,H), VM42E(B,H) and VM42EP(B,H)
Page 24 · click to enlarge
Page 24

Parts

Models M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H), VM36E(B,H), VM36EP(B,H), VM42E(B,H) and VM42EP(B,H)

FMI VM36E(B,H) — Models M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H), VM36E(B,H), VM36EP(B,H), VM42E(B,H) and VM42EP(B,H) diagram (page 24)
Fig. 23 · Models M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H),…
Page 25 of the FMI VM36E(B,H) user manual — M36E(P)(B,H) VM36E(P)(B,H)
Page 25 · click to enlarge
Page 25

Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

KEY NO.

M42E(P)(B,H) VM42E(P)(B,H) DESCRIPTION QTY 1 14153 14153 Micro Switch 1 2 109098-01 109098-01 Wire Harness 1 3 108863-01 108863-01 24" Supply Connect Plug 1 4 108864-01 108864-01 Strain Relief 1/2" Bushing 1 5 106642-01 106642-01 Air Rod Retainer 1 6 106643-01 106643-01 Damper Rod Retainer 1 7 106651-01 107805-01 Panel Closure 2 8 14129 14129 Transformer 1 9 11201 11201 Nut, #8-32 4 10 106657-02 107811-02 Air Separator 1 11 11408 11408 Bushing 2 12 See page 26 Left Refractory 1 13 See page 26 Right Refractory 1 14 See page 26 Rear Refractory 1 15 See page 26 Bottom Rear Refractory 1 16 See page 26 Bottom Front Refractory 1 17 11186 11186 Scew, #8-32 2 18 20088 20088 Door Stop 1 19 106691-01 107839-01 Screen Rod 2 20 11109 11109 Screw, #8-32 x 1/2" 2 21 106699-01 106699-01 Transition 6" B-Vent Collar 1 22 106703-01 106703-01 Air Kit Door Assembly 1 23 11107 11107 Screw, #10-32 x 1/4" 4 24 106948-02 107823-02 Smoke Deflector 1 25 11165 11165 Screw, #10 x 5/8" 2 26 107796-01 107796-02 Grate Assy 1 27 107742-01 107742-02 Burner Pan 1 28 107795-01 107831-01 Burner Tube 1 29 107748-01 107748-01 Burner Brckt 1 30 107985-01 107985-02 Pilot Shield 1 31 901681-01 901681-01 Burner Clamp 1 32 11209 11209 Nut, #10-24 1 33 11147 11147 Screw, #10-24 x 1/2 1 34 901066-01 901066-01 Brass Air Mixer (NG) 1 901066-02 901066-02 Brass Air Mixer (LP) 1 35 901064-03 901064-08 Orifice (NG) 1 901065-13 901065-08 Orifice (LP) 1 36 108866-01 108866-01 Pilot (NG) 1 108866-02 108866-02 Pilot (LP) 1 37 108867-01 108867-01 Pilot Orifice (NG) 1 108867-02 108867-02 Pilot Orifice (LP) 1 38 11102 11102 Screw, #8-32 x 3/8 2 39 14569 14569 Gas Control Valve (NG) 1 14570 14570 Gas Control Valve (LP) 1 40 107741-01 107741-01 Valve Bracket 1 41 110286-01 110286-01 Ignition Module 1 42 111288-02 111288-02 Manual Valve w/ Flex Hose 1 43 22912 22924 Draft Diverter 1 44 108005-03 108005-03 Wire Harness 1 45 108005-02 108005-02 Wire Harness 1 46 11418 11418 Push-On Nut 2 47 12105 107840-01 Screen 2 48 14123 14123 Strain Relief 1 49 14574 106543-01 Limit Switch 1 50 20280 20280 Top Spacer 4 51 20023 20023 Starter Collar 1 52 20027 20027 Brick Liner Retainer 2 53 20042 20042 Air Kit Cover 1 54 20090 20090 Spring Clip 2 55 20089 20089 Pivot Clip 2 PARTS AVAILABLE NOT SHOWN 901157-01 901157-01 Lava Rock 1

M36E(P)(B,H) VM36E(P)(B,H)

Page 26 of the FMI VM36E(B,H) user manual — M36(B,H) VM36(B,H)
Page 26 · click to enlarge
Page 26

Parts This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

FMI VM36E(B,H) — M36(B,H) VM36(B,H) diagram (page 26)
Fig. 24

KEY NO.

M42(B,H) VM42(B,H) DESCRIPTION QTY 12 106658-02 107812-02 Left Refractory, Std. Brick (M36EB/ME42B) 1 108164-02 108169-02 Left Refractory, Herringbone (M36EH/M42EH) 1 106658-01 107812-01 Left Refractory, Std. Brick (VM36EB/VM42EB) 1 108164-01 108169-01 Left Refractory, Herringbone (VM36EH/VM42EH) 1 13 106659-02 107814-02 Right Refractory, Std. Brick (M36EB/M42EB) 1 108165-02 108170-02 Right Refractory, Herringbone (M36EH/M42EH) 1 106659-01 107814-01 Right Refractory, Std. Brick (VM36eB/VM42EB) 1 108165-01 108170-01 Right Refractory, Herringbone (VM36EH/VM42EH) 1 14 106660-02 107816-02 Rear Refractory, Std. Brick (M36EB/M42EB) 1 108166-02 108171-02 Rear Refractory, Herringbone (M36EH/M42EH) 1 106660-01 107816-01 Rear Refractory, Std. Brick (VM36EB/VM42EB) 1 108166-01 108171-01 Rear Refractory, Herringbone (VM36EH/VM42EH) 1 15 106661-02 107818-02 Bottom Rear Refractory, Std. Brick (M36/ME42, M36B/M42EB) 1 108167-02 108172-02 Bottom Rear Refractory, Herringbone (M36H/M42H) 1 106661-01 107818-01 Bottom Rear Refractory, Std. Brick (VM36E/VM42E, VM36EB/VM42EB)

M36(B,H) VM36(B,H)

108167-01 108172-01 Bottom Rear Refractory, Herringbone (VM36EH/VM42EH) 1 16 106662-02 107820-02 Bottom Front Refractory, Std. Brick (M36E/M42E, M36EB/M42EB)

108168-02 108173-02 Bottom Front Refractory, Herringbone (M36EH/M42EH) 1 106662-01 107820-01 Bottom Front Refractory, Std. Brick (VM3E6/VM42E, VM36B/VM42B)

108168-01 108173-01 Bottom Front Refractory, Herringbone (VM36EH/ VM42EH) 1

Page 27 of the FMI VM36E(B,H) user manual — Logsets for models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H)
Page 27 · click to enlarge
Page 27

Parts

Logsets for models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H)

FMI VM36E(B,H) — Logsets for models M36(B,H), M36P(B,H), VM36(B,H) and VM36P(B,H) diagram (page 27)
Fig. 25 · Logsets for models M36(B,H), M36P(B,H), VM36(B,H) an…

KEY NO. PART NO. DESCRIPTION QTY. - 107999-01 Log Set 1 108724-01 Right Front 9" Split Log 1 2 901098-01 Rear Log 1 3 108720-01 Top Right Log - 11 3/4" 1 4 108721-01 Top Right Log - 16" 1 5 108722-01 Top Left Log - 13 1/2" Y-Log 1 6 108723-01 Top Left Log - 11" 1

Page 28 of the FMI VM36E(B,H) user manual — Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H)
Page 28 · click to enlarge
Page 28

Parts

Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H)

FMI VM36E(B,H) — Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H) diagram (page 28)
Fig. 26 · Logsets for models M42(B,H), M42P(B,H), VM42(B,H) an…
FMI VM36E(B,H) — Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H) diagram (page 28)
Fig. 27 · Logsets for models M42(B,H), M42P(B,H), VM42(B,H) an…

KEY NO. PART NO. DESCRIPTION QTY. - 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 11" 1 2B 108839-01 Right Front Log - 15 3/4" Round 1 3 108722-01 Top Left Log - 13 1/2" Y-Log 1 4 108838-01 Inside Top Left Log - 15 3/4" Split 1 5 108721-01 Inside Top Right Log - 16" 1 6 108720-01 Top Right Log - 11 3/4" 1

FMI VM36E(B,H) — Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H) diagram (page 28)
Fig. 28 · Logsets for models M42(B,H), M42P(B,H), VM42(B,H) an…
Page 29 of the FMI VM36E(B,H) user manual — Logsets for models M42(B,H), M42P(B,H), VM42(B,H) and VM42P(B,H)
Page 29 · click to enlarge
Page 29

Accessories Notice: All accessories may not be available for all fireplace models. Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back page of this manual.

Air kit - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.

Blower Kit BK - Squirrel Cage Blower With Speed Control

Perimeter Trim PT36 - 36", Black PT36B - 36", Brushed Brass PT36P - 36", Platinum PT42 - 42", Black PT42B - 42", Brushed Brass PT42P - 42", Platinum

Remote Control Kits WRC - Standard On/Off Electronic Remote Control Kit

Extruded aluminum bi-fold glass doors BD36 - 36" Black Finish BD36B - 36" Brushed Brass Finish BD36P - 36" Platinum Finish BD42 - 42" Black Finish BD42B - 42" Brushed Brass Finish BD42P - 42" Platinum Finish

Louver Trim Kit (Rolled Louvers Only) LT36B - 36", Brushed Brass LT36P - 36", Platinum LT42B - 42", Brushed Brass LT42P - 42", Platinum

Fixed glass doors FD36 - 36" Black Finish FD36B - 36" Brushed Brass Finish FD36P - 36" Platinum Finish FD42 - 42" Black Finish FD42B - 42" Brushed Brass Finish FD42P - 42" Platinum Finish

Face/Louver Panel Kits SP36, SP42 - Smooth Faced, Black SL36, SL42 - Stamped, Black RL36, RL42 - Rolled, Black FP36, FP42 - Filigree Panel, Black FP36B, FP42B - Filigree Panel, Brushed Brass FP36P, FP42P - Filigree Panel, Platinum

Brick Liner Kit (For M36(B,H), M36P(B,H), M42(B,H) and M42P(B,H) BL36 - 36" Refractory Standard Brick BL42 - 42" Refractory Standard Brick BL36H - 36" Refractory Herringbone Brick BL42H - 42" Refractory Herringbone Brick

FIRE CRACKLE - CF6-A Creates the sound of a real burning fire.

PROPANE/NATURAL GAS CONVERSION KIT PCBE-36 - Propane/LP Gas, Electronic Models NCBE-36 - Natural Gas - Electronic Models PCBE-42 - Propane/LP Gas, Electronic Models NCBE-42 - Natural Gas, Electronic Models

(For VM36(B,H), VM36P(B,H), VM42(B,H) and VM42P(B,H) BL36S - 36" Refractory Standard Brick BL42S - 42" Refractory Standard Brick BL36HS - 36" Refractory Herringbone Brick BL42HS - 42" Refractory Herringbone Brick

Page 30 of the FMI VM36E(B,H) user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 30 · click to enlarge
Page 30

NOTES

Page 31 of the FMI VM36E(B,H) user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 31 · click to enlarge
Page 31

NOTES

Page 32 of the FMI VM36E(B,H) user manual — FMI PRODUCTS, LLC LIMITED WARRANTIES
Page 32 · click to enlarge
Page 32

Warranty

KEEP THIS WARRANTY

Model (located on product or identification tag)

Serial No. (located on product or identification tag)

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties The following terms apply to all of the above warranties: Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented. This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product. This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner. Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s). This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) year on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product. FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact:

2701 S. Harbor Blvd. Santa Ana, CA 92704

108796-01 Rev. U 09/09

1-866-328-4537 www.fmiproducts.com

Date Purchased

Ask about the FMI VM36E(B,H)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI VM36E(B,H)

Be the first to ask — other owners or our team will answer.

Original document

FMI VM36E(B,H) manual PDF

32 pages·2.9 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…