2-SIDED (SEE-THROUGH), VENTED DECORATIVE GAS APPLIANCE OWNER’S OPERATION AND INSTALLATION MANUAL

US
NATURAL GAS MODELS (V)GL36ST AND (V)GL36STE PROPANE/LP GAS MODELS (V)GL36STP AND (V)GL36STEP
FOR YOUR SAFETY — Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com


This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. How ever, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

16. Do not install fireplace directly on carpeting, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been ex posed to or under water. Immediately call a qualified service person to arrange for replace ment of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings.
11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fire place where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electri cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combus tion chamber along with adequate accessibility clearance for servicing and proper operation.
2 1/2" 6"(152 mm)
6" O.D.
9 1/2"
21 1/4"
15 1/4"
(540 mm) (387 mm)
42 1/2"
4 1/2"
1 1/2"
7 1/2"
52 1/2"
37 1/2"
20 1/2"
5 1/2"
36 1/2"
(229 mm) (140 mm)
42 1/2"

Introduction Models (V)GL36ST/P and (V)GL36STE/EP are decorative gas appliances that use a millivolt gas control and piezo pilot or an electronic gas control valve with an electronic ignition system respectively. These systems require a 6", B-type venting system for operation. The 6" B-type vent is not supplied by FMI PRODUCTS,LLC . For installation guidelines, check your B-vent instructions.
Fuel Gas Code, ANSI Z223.1/NFPA 54. This appliance complies with ANSI Z21.50 as a Vented Gas Appliance and is listed and tested by the PFS Corporation.
Models (V)GL36ST and (V)GL36STE are smooth face units for natural gas only. The (V)GL36STP and (V)GL36STEP are smooth face units for propane/LP gas only. To determine which type of gas your unit is approved and tested for, check the rating plate on the lift-out plate located inside the firebox under the access panel.
Selecting Location To determine the safest and most efficient location for your appliance, you must take into consider ation the following guidelines: 1. The location must allow for proper clearances (see Clearances, page 6). Note: This decora tive appliance is not designed for outdoor installation. 2. The location should be in a place where drafts, air conditioning ducts, windows or doors will not affect fireplace heat output. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a typical two-sided fireplace installation. IMPORTANT: All fireplace openings must be located at least 3 feet from facing wall or com bustible material.
BEFORE YOU BEGIN Before beginning the installation of your appli ance, read these instructions through completely. This appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by FMI PRODUCTS, LLC. Unless you use FMI PRODUCTS,LL approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The FMI PRODUCTS,LLC warranty will be voided by and FMI PRODUCTS,LLC disclaims any respon sibility for the following actions : A) Modification of the appliance or any of
the components manufactured by FMI PRODUCTS,LLC unless otherwise permitted by FMI PRODUCTS,LLC. B) Use of any component part not approved by
FMI PRODUCTS,LLC in combination with this appliance. C) Installation and/or operation in a manner other
than instructed in this manual. D) The burning of anything other than the type of
gas approved for use in this gas appliance. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. The installation must conform with local codes or, in the absence of local codes, with the current National
4" From Opening to Perpendicular Wall
Figure 2 - Typical Two-Sided Fireplace
Projected Wall · Existing Side Wall · Installation

1" (22 mm) Minimum Clearance to Combustibles
1" (22 mm) Minimum Clearance from Pipes to Combustibles
In selecting a location, the following precautions must be observed: 1. Do not connect this appliance to a chimney system used for a solid fuel burning fire place. 2. Install in an area providing ventilation and adequate combustion air. 3. Due to high temperatures, do not locate this appliance in high traffic areas or near furniture and draperies. 4. Never obstruct the front opening of the appli ance or the flow of combustion and ventilation air. Keep control compartments accessible. 5. DO NOT locate in the vicinity where gasoline or other flammable liquids may be stored. The appliance area must be kept clear and free from these combustible materials.
22 3/4" (578 mm)
11 3/8" (289 mm)
22 1/4" (565 mm)
6" O.D. (152 mm)
4" (102 mm) Min. from the Perpendicular Side Wall to the Fireplace Opening (Typ.)
Figure 3 - Clearances from Top View
1" (25 mm) Min. Clearance from Pipes to Combustibles
35" (889 mm) Min. to Effective Opening to Ceiling
Do Not Pack Space Between Spacer with Any Type of Insulation
Figure 4 - Clearances from Side View
Mantel Clearances Woodwork, such as wood trims, mantels and other combustible materials, should not be placed within 7" of the opening of this appliance (see Figure 5). Combustible material above the fireplace projecting more than 1 1/2" from the appliance’s front face must not be less than 12" from the ap pliance opening.
Figure 5 - Mantel Clearances
19" (483 mm) · Doublewall 6" B-Vent · 0" to Floor


framing Construct framing using dimensions shown if Figures 6, 7 and 8. (Use the figure applicable to your application.) Figure 6 shows the framing dimensions prior to having the appliance in place. Once the unit has been fitted, bring studs in against nailing flanges located on the side of the appliance making sure a 1" clearance is maintained as shown in Figure 7. If the fireplace is to be installed directly on carpet ing, tile (other than ceramic) or any combustible material other than wood flooring the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace (see Figure 8). The platform must be solid, flat and fully supported.
As Required by Design as Long as Ceiling Clearances are Maintained
Figure 8 - Appliance Must Be Installed
on a Wood or Metal Panel if Being Installed on Any Combustible Material
vent pipe installation A 6", B-1 type gas vent pipe is a double-wall, vent ing system (not supplied) which must be installed during rough framing of the appliance. Any B-1 type gas vent system may be used for proper vent ing as long as the vent system is installed per the vent manufacturer’s recommendations. FMI PRODUCTS,LLC supplies this appliance with a tapered starter pipe for a snug fit. Slide B-1 type vent pipe over this starter pipe until vent pipe is fully seated. Secure this first section of B-vent pipe by strapping the connector around the vent pipe and then tightening the strap (not supplied) with any 1/8" nut and bolt (see Figure 9). Note: Visually inspect for proper vent connection by looking inside top of appliance. If connection does not appear to be correct, contact your local service technician.
22 3/4" (578 mm)
52 3/4" (1340 mm)
Min.
Figure 6 - Framing Dimensions Prior to
B-1 Type Vent (Not Supplied)
1" Min. to Combustibles
Strap (Not Supplied) (Fasten with #6 Screw or Bolt)
Figure 7 - Securing Appliance with
Figure 9 - Installing B-Vent Pipe


Optional Outside air Kit (Model ak-4) The installation of an outside air kit should be completed during the rough framing of the fire place due to the nature of it's location. Outside combustion air is accessed through a vented crawl space.
Wall Switch Installation 1. Remove the J-box cover plate from side of appliance’s outer surround. 2. Using the 18 ga. millivolt wire and wall switch (both supplied), connect wiring per wiring diagram (see Figure 11). For more detail, see Wiring Diagrams on page 16. Note: If any of the original 10 feet supplied wire must be replaced, use Thermostat Millivolt Wire 18 AWG Type CL2-105 C or equivalent only. IMPORTANT: Do not hook up to standard 120 VAC household wiring.
Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow, bushes or other obstacles (see Figure 10). The maximum height for the air inlet termination cannot exceed 3 feet below the B-vent termination exhaust height.

Secure to Collars with Duct Tape or Screws

Air Inlet Location Must Allow For Bushes or Snow
Route Millivolt Wires (Supplied) Through Electrical Conduit Bushing
Figure 11 - Wall Switch Installation
Electronic models (gl36ste/ep) This appliance must be properly wired to stan dard 120v household current through the FMI PRODUCTS,LLC provided wall switch before its remote control unit can be used to activate the auto matic pilot ignition (turn fireplace flames ON).
Vent Hood Required for Wall Installation
Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)
Wall Switch Installation 1. Remove the J-box cover plate from side of appliance’s outer surround. 2. Using the 18 ga. wires coming through strain relief grommet on side of appliance’s outer wall to standard household 120 VAC current through the wall switch provided, as shown in Figure 12, page 9. For more detail, see Wiring Diagrams, page 16. Note: If any of the original 10 feet supplied wire must be replaced, use 20 AWG electrical wire or equivalent only.
Figure 10 - Outside Air Kit
Millivolt Models (GL36ST/STP) The installation of a wall switch in this millivolt control appliance allows you to activate the gas control valve without the use of normal current.
Wall Switch · (Supplied) · To Thermopile

assembly underneath the front ledge. A 1/8" NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the ap pliance (see Figures 13 and 14).

Pilot Gas Line Do Not Kink

Figure 12 - Wiring Through Outer Surround
Figure 13 - Millivolt Control Valve
GAS SUPPLY TESTING Note: This section is intended as a guide for quali fied technicians installing gas to this appliance.

E A From Gas Supply
Figure 14 - Electronic Control Valve
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas sup ply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). This unit has been tested for installation at high altitude. Higher altitudes affect the atmospheric pressure and heat valve of gaseous fuels. When installing this unit at high altitudes, the rated input will be lower than at sea level. The lowered oxygen content in the air and the lowered gas density require installation of a different size orifice in order to achieve clean combustion of the unit. Consult the unit data plate for the proper high-altitude orifice size. Fill out the information sticker attached to the unit when field converting. See Specifications, page 15, when derating. The gas control valve is secured to the burner pan

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the ap pliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 15, page 10. A 30" long, 1/2" NPT SCHD 40 flexible gas line (supplied) may be used between the incoming 1/2" NPT black iron gas line and the fireplace regulator (located inside the firebox, under the access plate). The incoming gas line may be routed toward the appliance from either the left or right hand side of fireplace outer surround.


To install: 1. Remove gas line cover plate from appliance’s outer surround at the location to be used. 2. Remove insulation from inside the gas line conduit sleeve. 3. Run gas line through sleeve. 4. Prepare incoming black iron gas line with Teflon tape or pipe joint compound. (Check local codes as to the use of Teflon tape.)
Typical Exterior Wall Gas Shutoff Installation
Figure 15 - Typical Exterior Wall Gas

Log Set Placement Carefully remove log set from packaging. Place the two bottom logs over grate and align with pins. Place three loose logs, or twigs, onto alignment pins on two bottom logs (see Figure 16).


WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a commercial leak detection solution to all con nections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
Figure 16 - Log Placement
Fireplace Facing Any non-combustible material may be used for facing (glass, tile, brick, etc.) as long as the proper clearances are adhered to and the fireplace open ings are not blocked or obstructed in any way. See Clearances, page 6, and Figure 17 on page 11. Use only heat-resistant, noncombustible mortar or adhesive when securing facing material to the front of the fireplace.
Shut-Off Installation · Bottom Logs · Top Logs (Twigs)

1/8" to 1/4" Pilot Burner Ignitor Flame

Do Not Block Effective Opening "L" Shaped Metal Support
Burner Flame Adjustment The air shutter, located at the base of the main burner tube, has been factory preset to the proper air to bas ratio which results in a long, blue, cleaner burning flame (see Figure 20). If readjustment is necessary, loosen the air shut ter screw and rotate air shutter until proper flame setting is achieved, retighten air shutter screw. See Figure 20 for air shutter location. Closing the air shutter reduces the air-to-gas mix, resulting in a longer, yellow flame wihich produces excessive carbon monoxide (CO) and could also cause sooting.
Figure 17 - Fireplace Facing Material
Mantels Mantels, combustible or non-combustible, may be constructed as long as proper clearances are observed (see Figure 2, page 6 and Clearances, page 6).
Pilot Assembly Adjustment The pilot assembly is factory preset for the proper flame height. Alteration to factory settings may have occurred during shipping. If this is the case, some minor readjustments may be necessary and should be done by a qualified technician. The pilot assembly is located behind the burner next to the rear refractory piece at the right-hand side. The thermopile (in millivolt models) or the sensor (in electronic models) should be engulfed with the pilot flame approximately 3/8" to 1/2" in order for the regulator to receive proper signal (see Figures 18 and 19).


Figure 20 - Air Shutter Adjustment
3/8" to 1/2" (10 mm - 13 mm) 1/8" (3 mm)
Figure 18 - Correct Pilot Flame Pattern -

Top Slot Under Frame
Optional Glass Door Glass doors are optional with this gas appliance (see Replacement Parts and Accessories, page 19).
Installing Glass Door 1. Be sure top spring clip hole is aligned with hole in fireplace frame (see Figure 21). Fit glass door top pin into aligned holes. 2. Swing inner end of bottom clip out away from fireplace frame. Fit door bottom pin into clip. Push clip into frame until bottom door pin slips into hole in frame. 3. Check door alignment. If doors do not align with each other, use top spring clip to align. a. Use Phillips screwdriver to loosen screw
Figure 21 - Installing Glass Doors
that holds top spring clip in place. b. Push spring clip left or right in its align
ment slot until door is at proper angle (aligned with opposing door). Moving spring clip to the LEFT (your left as you face the fireplace) moves glass door’s top, inner corner UP; moving spring clip to the RIGHT moves glass door’s top, inner corner DOWN. c. When door alignment is satisfactory, use
Phillips screwdriver to retighten spring clip screw.
Glass Doors Must be Fully Open (as Shown) or Fully Closed when Appliance is in Operation
Figure 22 - Glass Doors Shown Fully
Only doors certified with this appliance may be used. When operating doors, do not slam or abuse them. Always keep area below bottom edge of doors clear of obstacles or debris. Do not operate this appliance if glass doors are broken or dam aged. See Figure 22.

1. STOP! Read the safety information, column 1. 2. Turn wall switch to the OFF position. 3. Turn off all electric power to the appliance. 4. Open control access panel. 5. Push in gas control knob and turn clock wise to the OFF position (see Figure 23). Note: It is recommended that you maintain the gas control knob in the full OFF position during lengthy periods of seasonal non usage. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has
been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Figure 23 - Millivolt Control Valve
Millivolt models · Gas Control Knob · Position Indicator

C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has
TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove control access panel. 4. Push in gas control knob and turn clockwise to “OFF”. Do not force. 5. Replace control access panel.
been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
1. STOP! Read the safety information, column 1. 2. Set the thermostat to lowest setting (if applicable). 3. Turn off wall switch. 4. Open control access panel or louver. 5. Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you don’t smell gas, go to the next step. 6. Turn the main burner wall switch to the ON position for ignition. There will be a spark at the electrode. 7. Replace control access panel or louver once there is a flame at the burner. 8. If burner will not stay lit after several tries, flip the wall switch to OFF and call your service technician or gas supplier.
Figure 24 - Pilot
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
E A From Gas Supply
Figure 25 - Electronic Control Valve

Figure 26 - Pilot
Keep control compartment, logs, burner and area surrounding logs clean by vacuuming or brushing at least twice a year. Take care not to alter the set tings on the pilot assembly. Do not use abrasive liquids or cleaners for cleaning glass doors and trims. Any household glass cleaner should suffice. Do not clean doors when hot. Allow appliance to cool before cleaning.
TO APPLIANCE 1. Turn off all electric power to the appliance if service is to be performed. 2. Remove control access panel. 3. Close the gas valve.
Maintenance
Technical Service You may have further questions about installation, operation or troubleshooting. If so, contact FMI PRODUCTS, LLC’s Technical Service Depart ment at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready. You can also visit our web site at www.fmiproducts.com.
WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before each use and at least annually by a qualified service person. More frequent clean ing may be required due to excessive lint from carpeting, bedding material, pet hair, etc. It is imperative that the control compartments, burners and circulating air system be kept clean.

THERMOPILE
IGNITOR
DO NOT CONNECT
TO 120V
N.C.SW HEAT LIMIT SWITCH
O
T
O
N
TH
P
TP
F
F
O
MAIN GAS INCOMING
TH/TP
SUPPLY
PILOT SAFETY WIRE
WALL SWITCH
(SUPPLIED)
PILOT IGNITOR
INCOMING
(SUPPLIED) WALL SWITCH
MAIN GAS
SUPPLY
SENSOR
ON
OFF
BLACK
120V AC INCOMING
PV GND PV/MV TR MV TH IGN
WHITE
(FUSE BOX
GREEN
OR BREAKER)
N.C.SW HEAT LIMIT
EV1
GREEN
SWITCH
BLACK
WHITE
ELECTRICAL RATING:
120v, 60Hz, 0.7A
24V AC
STEP DOWN TRANSFORMER
120V AC
OPTIONAL REMOTE CONTROL
TO GAS LINE
BURNER
millivolt wiring diagram · Electronic wiring diagram

Millivolt system Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Pilot will not light
1. Check to see if you have gas supply 2. Hold regulator control valve in the PILOT position for 2 to 3 minutes to purge air. If you smell gas stop and wait for a few minutes before trying to light the fireplace 3. Remove debris and dirt, in spect and clean any other possible obstructions 4. Contact your gas supplier 5. Refer to section on pilot lighting 6. Have a qualified technician replace pilot line 7. Replace control valve (see Replacement Parts, page 19)
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position
Pilot goes out when wall switch is ON
Frequent pilot outage

Electronic ignition system Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Pilot will not light
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position
Pilot goes out when wall switch is ON
Frequent pilot outage

Purchase these fireplace replacement parts and accessories from your local dealer. If they can not supply these parts, call FMI PRODUCTS, LLC at 1-866-328-4537 for referral information. You can also write to the address listed on the back page of this manual. Before ordering, please have your appliance’s model name or number and part number of the item(s) you are ordering ready. The model name or number for your particular appliance may be found on the rating label located inside the appliance.
Burner Assembly - 23439 For use with all models.
ON/OFF Remote Control Kit - MLCR For Millivolt Units Only - Batteries required for receiver and transmitter.
Vent Hood - AK4 For use with all models.
Refractory Side Refractory - 23519 Bottom Refractory - 23516 Face - 112139-01 For use with all models.
Grate Assembly - 11159 For use with all models.
Log Set Assembly - 25793 Bottom Rear Log - 25795 Bottom Front Log - 25794 Top Left Log - 25797 Top Center Log - 25672 Top Right Log - 25796 For use with all models.
Transformer - 14129 For use with all models.
"B-1 Type" Vent Pipe For use with all models. Any B-1 type, 6" diam eter, gas vent pipe may be purchased from your local vent manufacturer.
piezo igniter - 14261 For use with all models.
orifice Natural Gas - 23105 Propane/LP Gas - 23106 For use with all models.
Wall Switch Kit - 22180 Wall Switch - 14112 Cover Plate - 14113 For use with all models.
DBGL36ST Black For use with all models.
Ignition Control - 110286-01 For use with all models.
Gas Valve Conversion Kit Millivolt Propane/LP Gas - PC-GL36 Millivolt Natural Gas - NC-GL36 Electronic Propane/LP Gas - PC-GL36E Electronic Natural Gas - NC-GL36E
DBBGL36ST Brushed Brass · DCGL36ST Platinum

Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties: Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented. This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product. This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner. Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s). This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) year on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product. FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact: