OWNER'S MANUAL Freestanding and Fireplace
Insert Pellet Stove

FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4 GF55-079 01/11/08

Congratulations! You are the owner of a state-of-the-art Pellet Stove.
Thank-you for purchasing a FPI FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the GREENFIRE DEALER in your area.
Safety Note: If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.
The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.




This is a copy of the label that accom- panies each GF55 & GFI55. We have printed a copy of the contents here for your reference.
Minimum clearances to combustible materials./ Les dégagements minimums aux matériels
A Sidewall to Unit (Du mur de côté à l'appareil) 8” (203 mm) B Top of unit to an unshielded 8” (203 mm) mantle
(Le sommet de l'unité à un manteau de cheminée non blindé) 8” (203 mm)
(De l'unité au sommet du parement) 8” (203 mm) D Unit to side facing (protruding ¾” [19 mm])
(De l'unité au côté du parement) 8” (203 mm)
(De la porte ouvrant au devant de protection de plancher) 6” (152 mm) F From side of unit to edge of floor protection (De l'ouverture
de porte pour prendre parti de protection de plancher) 6” (152 mm)
Le plancher combustible doit être protégé par
To Operate Stove: MANUAL MODE: When a fire has been established the stove settings are adjustable. / HIGH/LOW MODE: (Requires a thermostat) When
the thermostat calls for heat the stove settings are adjustable. When the thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW
setting until the thermostat contacts close again. / AUTO/OFF MODE: (Requires a thermostat) When the thermostat contacts close, the unit will light
automatically. Once up to temperature the stove settings are adjustable. When the thermostat contacts open, the stove will drop down to the LOW settings for
30 minutes. If within the 30 min the thermostat contacts close, the HEAT LEVEL will return to previous MANUAL setting or if the thermostat contacts remain open the stove begin its shutdown routine.
Pour faire fonctionner le poêle : MODE MANUEL : Lorsque le feu est bien établi, les réglages peuvent être ajustés. / MODE "HIGH/LOW" : (Nécessite un thermostat) Lorsque le thermostat requière de la chaleur, les réglages peuvent être ajustés. Lorsque les contacts du
thermostat ouvrent, le réglage du niveau de chaleur et les ventilateurs s'ajusteront au réglage " bas " jusqu'à ce que les contacts du thermostat se referment. / MODE "AUTO/OFF" : (Nécessite un thermostat) Lorsque les contacts du thermostat ferment, le poêle s'allumera
automatiquement. Lorsque la température adéquate est atteinte, les réglages peuvent être ajustés. Lorsque les contacts du thermostat ouvrent, le poêle s'ajustera aux réglages "LOW" pendant 30 minutes. Si les contacts du thermostat sont fermés pendant ces 30
INSTALLED AS A FIREPLACE INSERT STOVE MODEL (GFI55) / A INSTALLE
Combustible floors must be protected by a
Certified for use in Canada & USA
To Start Stove: Press the ON / OFF button. If the auger needs to be primed, press the Manual Auger Feed button until fuel starts to drop into the Burn Pot.
Certifié pour installation au
Canada et aux Etats-Unis.
GF55-081 J F M A M J J A S O N D 2008 2009 2010
On the GF55 the safety label is located on the underside of the hopper lid.
non-combustible material.
un matériel incombustible.
- See Owners Manual.
- Consultez le manual.
DO NOT REMOVE THIS LABEL / NE RETIREZ PAS CETTE ÉTIQUETTE
E From door opening of unit to edge of floor protection
On the GFI55 the safety label is located on the hopper cover behind the top faceplate.
FPI Fireplace Products International Ltd.
COMME UN MODÈLE SUR PIED DE POELE.
C Unit to top facing (protruding ¾” [19 mm])
Manufactured in Canada for /
Fabriqué dans le Canada pour:
D
F E
Pour démarrer le poêle: Appuyer sur le bouton "ON/OFF". Si le Auger nécessite d'être amorcé, appuyer sur le bouton manuel d'alimentation du Auger jusqu'à ce que les granules se déversent dans le pot de combustion.
combustibles:
INSTALLED AS A FREESTANDING STOVE MODEL (GF55) / A INSTALLE COMME UN
Minimum Alcove Width (La largeur minimum de l'alcove) 36” (914 mm) Minimum Alcove Height (La hauteur minimum de l'alcove) 48” (1219 mm) Maximum Alcove Depth (La profondeur maximum de l'alcove) 30” (762 mm)
MODÈLE FS, QU’IL SOIT ENCASTRÈ, SUR PIED OU DANS UNE MAISON MOBILE.
Minimum clearances to combustible materials./ Les dégagements minimums aux matériels
A Sidewall to Unit (Du mur de côté à l'appareil) 6” (152 mm) B Backwall to Unit (Du mur de derrière à l'appareil) 3” (76 mm)
C Corner to Unit (Du coin à l'appareil) 2” (51 mm) D Wall to vent (Le mur pour donner vent) 3” (76 mm)
(De la porte ouvrant au devant de protection de plancher) 6” (152 mm) NOTE: A combustible floor must be protected by a non-
E
D
(864mm). (Un plancher combustible doit etre protege par un
combustible material - Width 27" (686mm) by depth 34"
materiel incombustible. La largeur 27" (686 mm) par la
AUTO / OFF mode: Turn the thermostat down or off.
minutes, le réglage de niveau de chaleur retournera en réglages "MANUEL" ou si les contacts du thermostat restent ouverts, le poêle entamera le processus d'arrêt.
E From door opening of unit to edge of floor protection
The unit can be installed on a hard,
L'unité peut être installée sur un dur, la
stable non-combustible surface.
surface non-combustible stable.r.
profondeur 34" (864mm).)
combustibles:
Serial No. / No. De Serié: Greenfire GF55 (Stove) GFI55 (Insert)
installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in
manufacturers instructions for precautions required for passing a chimney through a combustible wall or ceiling. Electrical
instructions d'installation et d'opération du fabricant. Contactez les autorités locales de votre quartier concernant les
complete with components. Insert and Hearth mount installations; a listed single wall chimney liner may be used. Inspect
Très chaud quand allumé. Ne touchez pas,
Tenez loin des enfants, des vêtements, des
restrictions et les inspections d'installation. Consultez les codes de bâtiment locaux et les instructions du fabricant
Utilisation avec les combustibles sous forme de boulets uniquement. Utiliser seulement lorsque les portes avants et la
porte du réceptacle de cendre sont fermées. Si une ou des vitres devaient être remplacées, utilisez seulement du
verre céramique. Les composantes requises pour l'installation sont un évent PL certifié de 3in/75mm or 4in/100mm
meubles,de l’essence ou d’autres fluides
For Use With Only Pelletized Wood fuels. Operate only with viewing door and ash removal door closed. Only replace
glass with ceramic glass. Components required for installation: a 3 inch (75 mm) or 4inch (100 mm) listed PL vent,
les brûlures sévères peuvent résulter.
produisant des vapeurs inflammables.
Suitable For Mobile Home Installation (Accepté pour l'installation dans une maison mobile, test)
Administratives de l'Oregon 814-23-900 à 814-23-909". Installez et utilisez cet appareil seulement selon les
avec ses composantes. Les installations insertion et de mont de foyer ; un paquebot de cheminée de mur de seul
Administration Rules 814-23-900 through 814-23-909. Install and use only in accordance with the Manufacture’s
pour les précautions à prendre lorsque une cheminée doit être installée au travers un mur ou un plafond
This pellet appliance has been tested and listed for use in manufactured homes in accordance with Oregon
your area. Do not connect this unit to a chimney flue serving another appliance. See local building codes and
Cet appareil a été testé et certifié pour utilisation dans les maisons mobiles en accord avec les "Règles
Pour éteindre le poêle : MODE MANUEL ET " HIGH/LOW " : Appuyer sur le bouton "ON/OFF".
Listed Room Heater, Pelletized Fuel Type (Appareil de chauffage à granules certifié)
See installation and operating instructions accompanying appliance. /
Consultez le manuel avec les instructions d’installation et d’opération.
Model / Modèle:
MODE "AUTO / OFF" : Régler le thermostat à la baisse ou éteignez le.
rating: 120 volts, 60 hz, 4.3 Amps. Route cord away from the heater.
and clean Exhaust Venting system frequently.
Hot while operating. Do not
touch, severe burns may
result. Keep children, clothing,
furniture, gasoline or other
flammable vapors away.
énuméré peut être utilisé.
chaleur.

SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning
appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary.
FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations.
KEEP ASH PAN FREE OF RAW FUEL. DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A FIRE IN THE ASH PAN MAY OCCUR.
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
SOOT: Operation of the stove with insuffi cient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is ineffi cient. Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. See "Slider/Damper Setting".
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
CLEANING: There will be some build up of fl y ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets.
FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.
ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled.
If you have any questions with regards to your stove or the above- mentioned information, please feel free to contact your local dealer for further clarification and comments.
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 115 volts (4.6 Amps), 60 hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacture or a qualifi ed Greenfi re dealer. This unit's maximum power requirement is 520 watts.
SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, FPI ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Greenfire dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.
FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while
it is in use.

PELLET QUALITY
Please read this entire Owner’s Manual before installation and op- erating your Greenfi re Pellet Stove. Failure to follow these instruc- tions may result in property damage, bodily injury or even death.
Pellet quality is important, please read the following:
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).
Contact your local building or fi re offi cial to obtain a permit and any information on installation restrictions and inspection requirements for your area.
Your Greenfire Pellet Stove has been designed to burn wood pellets only. Do not use any other type of fuel, as this will void any warranties stated in this manual.
To prevent the possibility of a fi re, ensure that the appliance is properly installed by adhering to the installation instructions. A Greenfi re dealer will be happy to assist you in obtaining information with regards to your local building codes and installation restrictions.
The performance of your pellet stove is greatly affected by the type and quality of wood pellets being burned. As the heat output of various quality wood pellets differs, so will the performance and heat output of the pellet stove.
Be sure to maintain the structural integrity of the home when passing a vent through walls, ceilings, or roofs.
CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities such as high salt content. Dirty fuel will adversely affect the operation and performance of the unit and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer for a recommended pellet type.
The stove's exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe opera- tion of the pellet stove.
Do not burn with insuffi cient combustion air. A periodic check is recom- mended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove.
P.F.I. PELLET STANDARDS: Fines (fine particles) 1% maximum through a 1/8" screen Bulk Density 40 pound per cubic foot minimum Size 1/4” - 5/16” diameter 1/2" - 1-1/2" long maximum Ash Content 1% maximum (Premium grade) 3% maximum (Standard grade) Moisture Content 8% maximum Heat Content approximately 8200 Btu per pound minimum
When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the home and bolted to the fl oor. Make sure that the structural integrity of the home is maintained and all construction meets local building codes.
Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange fl ames).
ASH: The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning. The use of high ash fuels may result in the stove needing to be cleaned daily. A low ash fuel may allow longer intervals between cleaning.
If you have any questions with regard to your stove or the above-men- tioned information, please feel free to contact your local dealer for further clarifi cation and comments.
CLINKERING: Clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during the burning process. This hard mass will block the air flow through the Burn Pot Liner and affect the performance of the stove. Any fuel, even approved types, may tend to clinker. Check the Burn-Pot Liner daily to ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner (when the unit is cold) and clean/scrape the clinkers out. Clean the holes with a small pointed object if required. Refer to the section Routine Cleaning and Maintenance.
PELLET FEED RATES: Due to different fuel densities and sizes, pellet feed rates may vary. This may require an adjustment to the slider damper setting or to the auger feed trim setting on low.
Since FPI has no control over the quality of pellets that you use, we assume no liability for negative results in selection of wood pellets.
Store pellets at least 36” (1 m) away from the pellet stove.

1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On time to 2 sec- ond. This setting is for high-grade fuel only. Push the button until just the number 1 light is on, this is for a three (3) second on time (standard setting).
AUTO/OFF
MANUAL
AUGER TRIM
Figure 3: Circuit Board Control Panel Decal.
A. The stove and insert have a low limit safety switch located on the housing of the exhaust blower. If the exhaust temperatures drop below 120°F (49°C) the unit will shut down and will be required to go through a full start up procedure again.
The most common cause for this is an empty hopper. This switch should only be by-passed for testing purposes by a technician.
B. The stove and insert have a high limit safety switch located just below the hopper behind the external body panels. If the temperature of this switch reaches 200°F (93°C), the auger will stop feeding fuel and as the exhaust temperatures drop below 120°F (49°C), the unit will shut down.
The 200°F (93°C) switch is a manual reset and should only be reset by a service person who can first diagnose the reason for failure.
The two most likely causes are Convection Fan failure or High Limit Switch failure. Either one needs to be properly diagnosed and rectified.
Since this is a safety switch it should never be by-passed for any reason other than the service technician to test the operation.

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
HIGH / LOW MODE
All control of circuit board function is adjusted at the circuit board.
INITIAL START-UP: See "manual mode".
START-UP: Press the ON / OFF button. The stove will turn on. The system light will fl ash. The Auger Light will fl ash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.
OPERATION: When the thermostat calls for heat (contacts are closed) the stove settings are adjustable as per Manual Mode. When the thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts close again. *The LOW heat setting can be adjusted for different fuel qualities (see "Control Board Functions" section). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts close again.
TURNING OFF: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.
DO NOT unplug unit while Combustion fan is operating. This may lead to smoke escaping from the stove.
MANUAL position.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner. See "Control Board Functions" section.
OPERATION: When a fire has been established, the System Light will turn solid (after approximately 10 - 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed at this time to change the desired Heat Level Output setting.
Figure 5: Thermostat Switch in HIGH/LOW position.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control button. For the best efficiency and to prevent cycling, the convection blower should be left on at all times.
INITIAL START-UP: See "manual mode".
OPERATION: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in MANUAL. When the thermostat contacts open, the stove’s HEAT LEVEL and Fans will drop down to the LOW setting for 30 minutes. If the thermostat contacts close within the 30 min, the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open the stove automatically begins its shutdown routine. The stove will re- light when the thermostat contacts close again.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the low setting is too hot for the room. See "Control Board Functions" section.
TURNING OFF: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.
TURNING OFF: To turn the unit OFF, turn the thermostat down or off.
DO NOT unplug unit while Combustion fan is operating. This may lead to smoke escaping from the stove.
DO NOT unplug unit while Combustion fan is operating. This may lead to smoke escaping from the stove.
Figure 6: Thermostat Switch in ON/OFF position.

THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION.

A Qualified Service Technician or Installer must set the Slider Damper. This is used to regulate the airflow through the pellet stove. The slider damper knob is located on the left cab side (see Figure 7).
Figure 8: Effi cient Flame.
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).
Figure 7: Slider / Damper Knob.
If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox.
If, after long periods of burning, the fi re builds up and overfl ows the burn pot or there is a build up of clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider damper must be pulled out to compensate. Pulling the slider damper out gives the fi re more air.
The easiest way to make sure that an effi cient fl ame is achieved is to understand the characteristics of the fi re.
The combustion exhaust blower is a variable speed blower controlled by the heat output button. This blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down.
Incorrect use of the Damper will cause malfunction and poor results from your stove or insert.

The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value:
If after long periods of burning, the fi re continually builds up and overfl ows the burn pot or there is a build up of clinkers, this is an indication that the pellet fuel quality is poor or the stove may need cleaning. Check the stove for ash build up (clean if required) and adjust the slider / damper to produce the proper clean combustion.
a) Torx T-20 Screwdriver b) 5/16" Wrench or Socket c) 1" Soft Paint Brush d) Soft Cloth e) Vacuum with fi ne Filter Bag
Figure 9: Burn Pot Assembly.
DOOR GLASS CLEANING
The door lever can be found inbehind the right side of the door frame. To open the door, pivet the lever outwards and upwards until it unlocks.
Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass can be cleaned by wiping down the outside and inside of the glass with a dry soft cloth. If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel and a gas appliance glass cleaner, this may be purchased through most dealers. If a gas appliance glass cleaner is not available, use a damp paper towel dipped in fl y ash to clean the glass. After the glass has been cleaned use the dry soft cloth to wiping down the outside and inside of the glass.
Cleaning of the burn pot and liner must only be done when stove is cold. To remove the burn pot and burn pot liner, open the door using the door handle provided (located on the right-hand side of the stove). Swing the door open. Lift the liner from the burn pot. Lift the burn pot from the fi rebox by gently lifting up the front of the burn pot, then sliding the assembly from the air intake tube and the ignitor cartridge. See fi gure 9.
This is the ‘pot’ where the pellets are burned. Every two (2) to three (3) days (when the unit is cold), remove the burn-pot liner from the stove and inspected it to ensure proper air fl ow through the liner. Failure to keep the liner clean may cause a build up of fuel past the burn pot liner and up the drop tube. This will cause the auger to jam and may result in pellets burning in the drop tube and hopper. Using a metal scraper, remove material that has accumulated or is clogging the liner’s holes. Then dispose of ashes from the liner and from inside the burn-pot. Place the burn-pot back into the stove, making sure that the pipes are properly inserted into the burn pot and locater tabs (see fi gure 9) are properly seated in the locater holes. Place the liner back into the burn-pot, making sure that the ignitor hole in the liner is aligned with the ignitor tube. Push the liner up against the ignitor tube.
After extended use the gasketing may come loose. To repair this, glue the gasketing on using high-temperature fi berglass gasket glue / RTU silicone available from your local Greenfi re dealer. This is important to maintain an airtight assembly.
(2-3 days) · (2-3 days) · (weekly)

FRESH AIR INTAKE
The ash pan is located under the burner. Always dispose of the ashes into a metal container (never use cardboard, plastic or wood containers) stored away from combustibles. Monitor the ash level every week. Remember different pellet fuels will have different ash contents. Ash content is a good indication of fuel effi ciency and quality. Refer to "Safety Warnings and Recommendations" for disposal of ashes.
Inspect periodically to be sure that the intake pipe is not clogged with any foreign materials.
Freestanding: To remove the ash pan, simply turn the knob and pull out towards the front.
This vent should be cleaned every year or after two (2) tons of pellets (whichever happens fi rst). We recommend contacting your dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.
Insert: To remove the ash pan open the door, remove the burn pot liner and the burn pot, then pull the ash pan out.
DO NOT PLACE UNBURNED OR RAW PELLET FUEL IN ASH PAN.

Ash Pan Door Lock
Locked 12:00 o'clock position Open 9:00 o'clock position
Unplug the stove then open the right and left side panels to access the two blowers. Vacuum all dust from motors and impellers. The convection blower should be oiled twice yearly using 3 in 1 oil or similar light oil. The combustion blower requires no lubrication. Check gaskets and replace if needed.
Figure 10: Ash Pan Door Lock shown in 12:00 o'clock position.
Check all the hinges on the unit to ensure proper movement.
Open the door and the rod is located under the unit top, in the center of the stove just behind the door (see Figure 11). This handle is to be pushed in and out a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fl y ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run effi ciently.

Figure 11: Heat Exchanger Tube Cleaner.

POST SEASON CLEAN-UP
Once you are fi nished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove be cleaned and serviced as stated above. Also remove any remaining fuel from the hopper and auger.
Removal of the firebox backing for bi-annual cleaning (refer to Figure 12):
a) Open the door by lifting the handle, remove the burn pot and burn pot
liner.
b) Before trying to remove screws, lubricate all screws with penetrating
Painted surfaces should be wiped with a damp cloth periodically.
oil. ie. WD-40.
It is important to note that fi ngerprints and other marks can leave a per- manent stain on plated fi nishes. To avoid this, give the surface a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fi replace. Never clean surfaces when they are hot. Do not use other cleaners or abrasives as they may leave a residue or scratches, which can become permanently etched into the surface.
c) Loosen (do not remove) the four (4) screws that hold the brick liner
retainers in place. Remove side brick liners by sliding them from under the screwheads.
d) Pull the center panel out. Ensure not to damage the 1" insulation
attached to the back of the center panel.
e) Vacuum and clean thoroughly.
Installation of firebox backing:
The paint on the steel fi rebox panels may peel. This is due to extreme conditions applied to the paint and is not covered under warranty.
a) Return center panel to its original position.
b) Place the two (2) side panels back into the firebox, secure the two
(2) retainers and lock down by tightening the two (2) screws on each side.
c) Replace the burn pot and burn pot liner.
It is recommended that your Greenfire dealer replace the glass if broken.
d) Close the glass door and secure.
The door glass is made of high temperature PYRO CERAMIC 5 mm thick. The center panel is 15.4” x 9.0” (39.0 cm x 22.9 cm) and side panels are 2.6 x 9.0 inches (6.7 cm x 22.9 cm). They must be replaced with (Part # GF55-028 & GF55-029). Substitute materials will not be permitted.

Figure 12: Firebox Components Removal.
(season)

FPI is the manufacturer of the Greenfi re line of heating products. At FPI, our commitment to the highest level of quality and customer service is the most important thing we do. Each Greenfi re stove is built on a tradition of using only the fi nest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser. With Greenfi re, you’re not just buying a stove, you’re buying a company with years of unequalled performance and quality.
Limited Lifetime Warranty: Under this warranty, FPI covers the fi replace or stove body and accessories against defects in materials and workmanship, for part repair or replacement for the fi rst seven (7) years and limited labour for the fi rst two (2) years to the original purchaser. This Warranty covers: Firebox, Heat Exchanger, Burn Pot, Firebox Panels, Ceramic Glass, Pedestals, Panels, Legs, Log Sets and Door Assembly. Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty.
Limited Three (3) Year Warranty Under this warranty, FPI covers the Burn Pot Liner against defects in materials and workmanship, for part repair or replacement for the fi rst three (3) years and limited labour for the fi rst two (2) years to the original purchaser. Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty.
Limited Two (2) Year Warranty: Under this warranty, FPI covers: Auger Motor, Circuit Board, Timers, Temp Sensors, Blowers, Vacuum Switch and Wire Harness, against defects in materials and workmanship, for part repair or replacement for the fi rst two (2) years and limited labour for the fi rst two (2) years to the original purchaser. Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty.
Limited One (1) Year Warranty: Under this warranty, FPI covers the Ignitor and all exterior surface fi nishes against defects in materials and workmanship, for part repair or replacement and limited labour for the fi rst (1) year to the original purchaser. Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty.
Here is how our Warranty works If you have any concerns with your Greenfi re product please contact the dealer where you purchased the fi replace or stove. Your dealer shall make all claims in writing in reference to this warranty policy. Any and all parts and service will be handled through the selling dealer.
To the Dealer When fi lling out a warranty claim please complete the following information on an offi cial warranty claim form: Customer information: Name, address and telephone number of purchaser and date of purchase. Dealer information: Date of installation, name of installer and dealer, serial number of the appliance, nature of complaint, defects or malfunction, description and part numbers of any parts replaced.
To the Distributor Sign and verify that work and information are correct.

12. The Limited Warranty is void if: a) The stove has been operated in atmospheres contaminated by chlorine, fl uorine or other damaging chemicals. b) The stove is subject to submersion in water or prolonged periods of dampness or condensation. c) Any damage to the unit, combustion chamber or other components due to water, or weather damage which is the result of, but not limited to, improper chimney/venting installation. c) Salt air in coastal areas or high humidity can be corrosive to the fi nish; these environments can cause rusting. Damage caused by salt air or high humidity is not covered by the Limited Warranty.
13.Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or adjustment of the manufacturer’s settings of components, lack of proper and regular mainte- nance, alteration, or act of God.



FPI fi replaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.
FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product.
Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________
Greenfi re is a trademark of FPI Fireplace Products International Ltd.
© Copyright 2008, FPI Fireplace Products International Ltd. All rights reserved.
Owners and our team usually reply within a day — and your question helps the next person too.