VENTED DECORATIVE APPLIANCES OWNER’S OPERATION AND INSTALLATION MANUAL

LISTED BY
Models FVTR18
and FVTR24
RGA 2-72
APPROVED
Std RADCO Listing No. 1292
vapors and liquids in the vicinity of this or any other appliance.
a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
Save this manual for future reference.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.
2 901846

OPTIONAL PRODUCT FEATURES
An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conversion. See Ac- cessories, page 17.
An optional millivolt valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. This system may be connected to a wall switch or hand-held wireless remote control. See Ac- cessories, page 17.
Figure 1 - Product Identification
There is an optional hand-held ON/OFF remote control that can be purchased sepa- rately for this log set. You must use the millivolt valve/safety pilot kit to use remote accessories with this appliance. See Acces- sories, page 17.
UNPACKING
Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.
Model FTLCR18 log set is for use with Model FVTR18 burner set. Model FTLCR24 log set is for use with Model FVTR24 burner set. Use these log sets only with their corre- sponding burners.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

Confined and Unconfined Space
The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
This log set shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Log Set Location, page 5.
4 901846

Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Gas fireplace logs Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Vent-free heater Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Example: Gas water heater 40,000 Btu/Hr Gas fireplace logs + 55,000 Btu/Hr Total = 95,000 Btu/Hr
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)
95,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 901846

Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building
Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Inlet Air Ventilated Crawl Space
Figure 3 - Ventilation Air from Outdoors

*Add 2" if safety valve/pilot is used **At depth indicated
NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only fac- tory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or ac- cessory items will void the manufacturer’s warranty, and may result in a hazardous condition.
Figure 4 - Technical Information Charts
VENTING SPECIFICATIONS FOR INSTALLATION
Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 17). Call dealer where you bought log set.
The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled news- paper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.
If the fireplace does not have a gas supply shut-off valve, one must be installed.
The chimney flue must remain open a mini- mum of 3" at all times during the operation of this log set.
The charts in Figure 4 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable be- fore installation is attempted.
The fireplace must include a working flue and venting system with the minimum open- ings shown in the Figure 4.
Continued · 7 901846

We recommend that you install a sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 6).
Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 5. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.


Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.
Manufactured Fireplace Masonry Fireplace

Approved Flexible Gas Hose (if allowed by local codes)
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was con- nected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect log set and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Figure 6 - Gas Connection * Purchase the optional CSA design-certi- fied equipment shutoff valve from your dealer. See Accessories, page 17. ** Minimum inlet pressure for purpose of input adjustment.
Damper Clamp · Sediment Trap · 8 901846

5. Apply thread sealant to the 1/8" brass pipe nipple and thread it onto the mani- fold block. Tighten with a 7/16" wrench. 6. Slip the air restrictor over the 1/8" pipe nipple. Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting. Tighten with a 9/16" wrench. 7. Place the grate assembly over the burner pan. Install the rear burner bracket onto the grate with the 2 black Phillips head #10 screws provided. Do not tighten at this time (see Figure 9). 8. Install the “U” burner from the left side with the open end in the front (see Fig- ure 9). Hold the rear of the burner higher than the bracket. Slide the burner over the air restrictor fitting. Lower the rear of the burner into the slots on the burner bracket. Install the burner clip and tighten the nuts and screws. 9. Install 3/8" flare x 3/8" male pipe el- bow into the inlet of the manifold block. Install the pipe plug into the top of the manifold block. Use thread sealant.
Installation and Gas Connection 1. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant. 2. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. 3. Install the flex gas line to the gas sup- ply fitting. Carefully shape tube to at- tach to adapter fitting (see Figure 10). 4. Replace valve cover.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 7). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equip- ment shutoff valve (see Figure 7). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Burner Pan Assembly (Facing Front of Fireplace)
Figure 10 - Connecting Gas to Appliance
Figure 7 - Checking Gas Joints
Kit Assembly
Note: Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. 1. Remove burner inlet fitting from front burner (installed in burner pan, see Fig- ure 8). 2. Make sure ports on front burner are facing the front (open side) of burner pan. Refit if needed. 3. Using thread sealant (resistant to the action of propane/LP gas) on larger end of fitting, screw the burner inlet fitting through the hole and into the front burner (see Figure 8). Tighten using a 7/8" wrench. If using propane/LP gas, see Propane/LP Gas Conversions, page 10. 4. Apply thread sealant compound to the 3/8" male threads of the burner inlet fitting. Thread the manifold block (see Figure 8) onto the burner inlet fitting. Use the bottom hole of the block.
Figure 8 - Kit Assembly
Figure 9 - Installing Burner


9. Install valve cover to burner pan using screws provided. 10. Install thermocouple, pilot, and ignitor onto valve cover as shown in Figure 14. Use the provided screws. 11. Push the control rod extension onto the “D” shaped control rod through the cen- ter hole in the cover. 12. Install the position decal and control knob making sure to align the marks with the correct stop positions of the gas control. Pilot position will allow the knob to push in about 1/2". Align the decals in the pilot position.
For additional convenience and safety, or for propane/LP conversion, an optional ON/ OFF safety valve/pilot kit is available. See Accessories, page 17.
Natural Gas Installation 1. Thread the gas control valve onto the close pipe nipple (see Figure 11). Use thread sealant on the male threads of the fitting. Thread other end of the nipple into the burner manifold block. Hold the manifold block with a wrench to prevent stressing the connections to the burners. Make sure the control rod is facing the front (see Figure 11). 2. Attach the pilot gas line to the pilot out- let of the gas control valve and tighten. Connect the thermocouple to the rear of the gas control valve (see Figure 12). Do not overtighten (finger-tight plus 1/4 turn). If using propane/LP gas, see Changing Pilot Orifice, page 11. 3. Install the inlet fitting into the inlet opening of the gas control valve (see Figure 13). Use thread sealant on the male pipe threads. 4. Thread the gas supply fitting to the fire- place gas supply pipe (see Figure 10, page 9). Adjust to most convenient position. 5. Install the gas flex line to the gas supply fitting. Carefully shape tube to attach to adapter fitting. 6. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. 7. Test for leaks following instructions under Testing Burner for Leaks, page 11. 8. Retighten and adjust the location of the gas control as necessary. The gas con- trol should be level, with the control rod to the front.
Figure 14 - Installing Cover, Control Knob, and Piezo Ignitor
Figure 11 - Installing Gas Control Valve
To convert to propane/LP gas, the two main burner orifices and pilot orifice must be replaced.

Note: Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. Be sure to use the correct orifice for your unit. See chart on page 7. 1. Remove the burner inlet fitting from the front burner manifold (installed in burner pan). See Figure 15, page 11. 2. Make sure ports on front burner mani- fold are facing the front (open side) of burner pan. Refit if needed. 3. Replace front burner injector with the provided injector. See chart on page 7 and Figure 16, page 11. Using thread sealant (resistant to the action of pro- pane/LP gas) on larger end of fitting, screw the burner inlet fitting through the hole and into the burner manifold. Tighten using a 7/8" wrench.
Figure 12 - Gas Control Valve with Ther- mocouple and Pilot
Gas Control Valve Gas Inlet Fitting
Figure 13 - Installing Inlet Fitting and Gas Connector Tube

TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections.
The pilot is provided with a natural gas orifice installed. For propane/LP gas you must remove it and replace it with an pro- pane/LP orifice. The hardware kit contains an propane/LP orifice with a red stripe for converting the pilot. 1. Gently loosen and remove the pilot line connection from the bracket (see Figure 17). 2. Replace the injector (see Figure 17) with the propane/LP pilot injector with the red stripe. 3. Replace and tighten the pilot line to the bracket. 4. Continue with step 3 under Natural Gas Installation, page 10.
4. Apply thread sealant compound to the 3/8" male threads of the burner inlet fitting. Thread the manifold block (see Figure 15) onto the burner inlet fitting. Use the bottom hole of the block. 5 . Apply thread sealant to the 1/8" brass pipe nipple and thread it into the mani- fold block (see Figure 15). Tighten with a 7/16" wrench. 6. Slip the air restrictor over the 1/8" pipe nipple. Apply thread sealant to the male threads and install the rear burner injec- tor provided with the GA9003 (see chart on page 7) onto the fitting. Tighten with a 9/16" wrench. Proceed with step 7, page 9 in Hearth Kit Assembly.
2. Light the burner with the shutoff valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 12). 3. Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are de- tected, shut off the gas valve immedi- ately. Tighten, or reassemble the loose connection(s) using pipe joint com- pound until burner system is leak free. 4. When the burner is tested and leak free, observe the individual tongues of flame on the burner. Note: The burner design includes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool. 5. When finished testing, turn the gas shutoff valve OFF to extinguish all flames.
Figure 17 - Installing Propane/LP Pilot Orifice
ADDING PAN MATERIAL 1. Open the bag of ash bed material (ver- miculite) and spread it evenly across the burner pan to the top. You may over- flow the front and sides of the pan to cover the entire pan and connecting hardware. 2. Open the glowing embers and evenly cover the ash bed material (vermicu- lite) in the burner pan.
Figure 15 - Kit Assembly
Injector for Natural Gas
INLET FITTING
Figure 16 - Burner Inlet Fitting with Injectors

OPERATING APPLIANCE
INSTALLING THE EMBER BED AND LOGS (Split Oak Sets Shown) 1. Place the ember bed (included with burner set) over log grate as shown in Figure 18. 2. Position the back log flush against back of ember bed as shown in Figure 19. 3. Place the middle layer of logs as shown in Figure 20. Notice the grove in the back log for placement of log to the far right. Adequate space should be left between logs and ember bed for flames. 4. Place the top layer of logs as shown in Figure 21.
READ BEFORE
LIGHTING
Figure 20 - Installing Logs
BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
Figure 21 - Installing Logs
Figure 18 - Installing Ember Bed

1. STOP! Read the safety information, above. 2. Turn the gas shutoff valve to OFF. 3. Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Fol- low the safety information above. If you don’t smell gas, go on to the next step. 4. Light a match and lay it on top of the “U” shaped burner near the edge of the cover on the right side of the pan. 5. Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again.
Figure 19 - Installing Back log
Grate Ember Bed · 12 901846

GAS SHUTOFF VALVE OPERATION
Note: Operation instructions for GA9103 Remote Ready Valve/Pilot Kit will be included with the Kit. 1. STOP! Read the safety information, page 12. 2. Make sure equipment shutoff valve is fully open. 3. Press in and turn control knob clock- wise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! See Safety information, page 2 and Air For Combustion And Ventila- tion, pages 4 through 6. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise
to the ON position. Burner should light. If burner does not light, call a qualified service person.
Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise
ON
OFF
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF PULL PUSH
ON OFF
ON FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH
Turn gas shutoff valve clockwise to the OFF position.
SLIGHT PUSH TO
TURN OFF
PULL PUSH
OFF
CURING LOGS
Figure 22 - Ignitor and Control Knob
to the PILOT position and press in. Keep control knob pressed in for five (5) seconds. Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 sec- onds. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.
Figure 23 - Thermocouple and Pilot
TO APPLIANCE
Shutting Off Appliance 1. Turn control knob clockwise to the PILOT position. 2. Press in and turn control clockwise
to the OFF position. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise to the PILOT position.

TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set.
Log set is smoking/sooting excessively (Note: It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flames contact the logs. This is especially true with propane/LP gas.)
Burner is excessively noisy (Note: The movement and combustion of gas will create low, unavoidable levels of noise.)
Burner flame is too low or too high
14 901846

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at pilot (GA9003 Only)
When ignitor button is pressed, there is spark at pilot but no ignition (GA9003 Only)
Pilot lights but flame goes out when control knob is released (GA9003 Only)
B) Clean pilot (see Cleaning and Mainte- nance, page 17) or replace pilot assembly
Burner does not light after pilot is lit (GA9003 Only)
Delayed ignition burner (GA9003 Only)
www.desatech.com Continued
15 901846

POSSIBLE CAUSE
REMEDY
Log Set produces a clicking/ticking noise just after burner is lit or shut off
Log Set produces unwanted odors
Gas odor even when control knob is in OFF position
Gas odor during combustion
16 901846

ACCESSORIES
Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-888-2050 for information. You can also write to the ad- dress listed on the back page of this manual.
For all models. Use for additional decora- tion only. Carton of 6 Boxes (3 pine cones per box).
For all models. Carton of 6.
REPLACEMENT PARTS
For all models. Use for firebox decoration only.
EQUIPMENT SHUTOFF VALVE GA5010
For all models. Use for firebox decoration only. Carton of 6.
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
Contact authorized dealers of this product . If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800- 337-2564).
For all models. Use for firebox decoration only.
RECEIVER AND HANDHELD REMOTE CONTROL KIT - GHRC Series
An attractive way to cover control knob and piezo ignitor.
For all models. Allows the gas log set to be turned on and off by using a hand-held remote control. Valve/Pilot Kit GA9103 must be used with this remote.
Usually, we will ask you to return the defec- tive part to the factory.
For 18" models only. Additional decoration for front grate.
ON/OFF SAFETY VALVE/ PILOT KIT - GA9003 (Not Shown)
24" ORNAMENTAL GRATE ENHANCER - GA9320 (Not Shown)
Contact authorized dealers of this product or Parts Central (see page 20). If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.
For all models. Required for Propane/LP installation.
For 24" models only. Additional decoration for front grate.
For all models.
17 901846



18 901846

PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR18
KEY PART NO. NUMBER DESCRIPTION QTY.
1 098249-01 ODS Nut 2 2 901752-02 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-01 Log Grate 1 5 098304-01 Screw, 10-16 x .38 4 6 901762-01 Burner Bracket 1 7 901754-02 Front Burner 1 8 901753-02 Burner Pan 1 9 901750-01 Nozzle 1 10 901064-05 Natural Gas Injector 1 11 901066-01 Brass Air Mixer - Natural Gas 1 12 901761-01 1/8 Hex Nipple 1 13 901760-01 Manifold Block 1 14 901751-01 Air Restrictor 1 15 901756-01 Valve Cover 1 16 901056-01 Brass Elbow Flare Fitting 1 17 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 18 101628-01 Gas Line - 10" Flex 1 19 901769-02 Ember Bed 1 20 901591-08 Top Log VCR11/FS 1 21 901528-03 Top Log CS-16/FS 1 22 901619-01 Top Log FS12Y 1 23 901612-01 Top Log FS17 1 24 901676-04 Top Log CS-13Y/FS 1 25 901530-02 Bottom Log CSB-18/FS 1 26 901759-01 Manifold Plug 1
901036-01 RADCO GEN Rating Plate 1 901039-08 Rating Information Plate 1 901242-01 Damper Clamp 1
19 901846



20 901846

PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR24
KEY PART NO. NUMBER DESCRIPTION QTY.
1 098249-01 ODS Nut 2 2 901752-01 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-02 Log Grate 1 5 098304-01 Screw, 10-16 x .38 4 6 901762-01 Burner Bracket 1 7 901754-01 Front Burner 1 8 901753-01 Burner Pan 1 9 901750-01 Nozzle 1 10 901064-01 Natural Gas Injector 1 11 901066-01 Brass Air Mixer - Natural Gas 1 12 901761-01 1/8 Hex Nipple 1 13 901760-01 Manifold Block 1 14 901751-01 Air Restrictor 1 15 901756-01 Valve Cover 1 16 901056-01 Brass Elbow Flare Fitting 1 17 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 18 101628-01 Gas Line - 10" Flex 1 19 901769-01 Ember Bed 1 20 901527-05 Top Log CS-12/FS 1 21 901528-03 Top Log CS-16/FS 1 22 901619-01 Top Log FS12Y 1 23 901540-03 Top Log CS-18/CC 1 24 901612-01 Top Log FS17 1 25 901532-02 Bottom Log CS-24/FS 1 26 901759-01 Manifold Plug 1
901036-01 RADCO GEN Rating Plate 1 901038-04 Rating Information Plate 1 901242-01 Damper Clamp 1
21 901846



Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects on burner system for two (2) years and logs for a lifetime from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com