NATURAL GAS LOGp.1VENTED DECORATIVE APPLIANCES OWNER’S OPERATION AND INSTALLATION MANUALp.1TESTED ANDp.1LISTED BYp.1Models FVTR18p.1and FVTR24p.1RGA 2-72p.1APPROVEDp.1— Do not store or use gasoline or other flammablep.1— WHAT TO DO IF YOU SMELL GASp.1— Installation and service must be performed byp.1SAFETY INFORMATIONp.2WARNING ICON G 001 WARNINGSp.2PRODUCT IDENTIFICATIONp.3OPTIONAL PRODUCT FEATURESp.3ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSIONp.3REMOTE CONTROL READY (MILLIVOLT) SAFETY VALVE/ PILOT KITp.3REMOTE CONTROL ACCESSORIESp.3LOCAL CODESp.3UNPACKINGp.3LOG SETSp.3AIR FOR COMBUSTION AND VENTILATIONp.4PROVIDING ADEQUATE VENTILATIONp.4Confined and Unconfined Spacep.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.6Ventilation Air From Inside Buildingp.6Ventilation Air From Outdoorsp.6INSTALLATIONp.7CHECK GAS TYPEp.7VENTING SPECIFICATIONS FOR INSTALLATIONp.7FLUE OPENING SPECIFICATIONSp.7INSTALLATION Continuedp.8INSTALLING DAMPER CLAMPp.8CHECKING GAS CONNECTIONSp.8Pressure Testing Gas Supply Piping Systemp.8HEARTH KIT ASSEMBLY AND INSTALLATIONp.9Kit Assemblyp.9OPTIONAL GA9003 SERIES ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLYp.10Propane/LP Gas Conversionp.10BURNERp.11INLET FITTINGp.11OPERATING APPLIANCEp.12FOR YOUR SAFETYp.12READ BEFOREp.12LIGHTINGp.12LIGHTING INSTRUCTIONSp.12OPERATING APPLIANCE Continuedp.13OPERATING INSTRUCTIONS FORp.13GA9003p.13GAS SHUTOFF VALVE OPERATIONp.13Flame Adjustmentp.13to open or clockwise to close, as necessary. Shutting Off Appliancep.13ONp.13OFFp.13FROM "PILOT" POSITIONp.13SLIGHT PUSH TOp.13TURN OFF PULL PUSHp.13ON OFFp.13TURN OFFp.13PULL PUSHp.13CURING LOGSp.13TO TURN OFF GASp.13TO APPLIANCEp.13POSSIBLE CAUSE REMEDY OBSERVED PROBLEMp.14TROUBLESHOOTING Continuedp.15OBSERVED PROBLEMp.15POSSIBLE CAUSEp.15REMEDYp.15CLEANING AND MAINTENANCEp.17ACCESSORIESp.17PINE CONES - GA9600 (Not Shown)p.17ASH BED MATERIAL (Vermiculite) - GA9700 (Not Shown)p.17GLOWING EMBERS - GA9900 (Not Shown)p.17REPLACEMENT PARTSp.17SILICA SAND - GA9800 (Not Shown)p.17EQUIPMENT SHUTOFF VALVE GA5010p.17
Page 1 of the FMI FVTR18 user manual — — Installation and service must be performed by
Page 1 · click to enlarge
Page 1

NATURAL GAS LOG

VENTED DECORATIVE APPLIANCES OWNER’S OPERATION AND INSTALLATION MANUAL

FMI FVTR18 — NATURAL GAS LOG diagram (page 1)
Fig. 1

TESTED AND

LISTED BY

Models FVTR18

and FVTR24

RGA 2-72

APPROVED

Std RADCO Listing No. 1292

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Page 2 of the FMI FVTR18 user manual — WARNING ICON G 001 WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is convertible for use with propane/LP, using the GA9003 or GA9103 pilot kit. 2. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 3. Never install the log set
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set
  • in high traffic areas
  • in windy or drafty areas 4. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. 5. You must operate this log set with a fireplace screen in place. Make sure fireplace screen is closed before running log set. 6. This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window. 7. To reduce the creation of soot, follow the instructions in Cleaning and Maintenance , page 17. 8. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.
  • 9. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this log set. 10. This log set needs fresh, outside air ventilation to run properly. See Air for Combustion and Ventilation , pages 4 through 6. 11. Do not run log set
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 12. Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects. 13. Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set will remain hot for a time after shutdown. Allow surface to cool before touching. 14. Carefully supervise young children when they are in the room with log set. 15. Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the control system (if using GA9003 or GA9103) and any gas control which has been under water. 16. To help prevent breakage, new logs must be broken-in (see Curing logs, page 13). 17. Turn log set off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair log set.

WARNING ICON G 001 WARNINGS

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

2 901846

Page 3 of the FMI FVTR18 user manual — LOG SETS
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

OPTIONAL PRODUCT FEATURES

ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSION

An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conversion. See Ac- cessories, page 17.

REMOTE CONTROL READY (MILLIVOLT) SAFETY VALVE/ PILOT KIT

An optional millivolt valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. This system may be connected to a wall switch or hand-held wireless remote control. See Ac- cessories, page 17.

Figure 1 - Product Identification

REMOTE CONTROL ACCESSORIES

There is an optional hand-held ON/OFF remote control that can be purchased sepa- rately for this log set. You must use the millivolt valve/safety pilot kit to use remote accessories with this appliance. See Acces- sories, page 17.

LOCAL CODES

UNPACKING

Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.

LOG SETS

Model FTLCR18 log set is for use with Model FVTR18 burner set. Model FTLCR24 log set is for use with Model FVTR24 burner set. Use these log sets only with their corre- sponding burners.

*Available from:

1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

Show 7 more labels / short text on this page
Rear Burner · Grate · Burner Pan · Front Burner · Valve Cover · Serial Number ________________________________________ · 3 901846
Page 4 of the FMI FVTR18 user manual — Unusually Tight Construction
Page 4 · click to enlarge
Page 4

AIR FOR COMBUSTION AND VENTILATION

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

This log set shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Log Set Location, page 5.

4 901846

Page 5 of the FMI FVTR18 user manual — DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Gas fireplace logs Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Vent-free heater Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Example: Gas water heater 40,000 Btu/Hr Gas fireplace logs + 55,000 Btu/Hr Total = 95,000 Btu/Hr

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)

95,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 901846

Page 6 of the FMI FVTR18 user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION AND VENTILATION Continued

Ventilation Grills Into Adjoining Room,

VENTILATION AIR

Or Remove Door into Adjoining

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 14 more labels / short text on this page
12" · Ventilation · Grills Into Adjoining · Room, Option 1 · Option 2 · Room, Option · 12" · Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · Inlet Air · 6 901846
Page 7 of the FMI FVTR18 user manual — FLUE OPENING SPECIFICATIONS
Page 7 · click to enlarge
Page 7

INSTALLATION

MODELDESCRIPTIONBtu Input Natural GasBtu Input Propane GasMinimum Vent Opening FVTR18 FVTR2418" Triple Burner 24" Triple Burner60,000 70,00050,000 60,0008" dia. 8" dia.
MINIMUM FIREBOX SIZES LOG SIZEFRONT WIDTH*BACK WIDTH**DEPTHHEIGHT 18" 24"28" 29 3/ " 416" 17"14" 15 1/ " 218" 18"

*Add 2" if safety valve/pilot is used **At depth indicated

FUEL INLET PRESSURE SPECIFICATIONS ("W.C.) Min.Max. NG5.510.5 LP1113
BURNER ORIFICE LOG SIZENATURALPROPANE/LP FRONTREARFRONTREAR 18" 24".046 .0644x.064 4x.064.036 .0364x.043 4x.0465

NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only fac- tory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or ac- cessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

Figure 4 - Technical Information Charts

CHECK GAS TYPE

VENTING SPECIFICATIONS FOR INSTALLATION

Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 17). Call dealer where you bought log set.

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled news- paper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

If the fireplace does not have a gas supply shut-off valve, one must be installed.

FLUE OPENING SPECIFICATIONS

The chimney flue must remain open a mini- mum of 3" at all times during the operation of this log set.

The charts in Figure 4 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable be- fore installation is attempted.

The fireplace must include a working flue and venting system with the minimum open- ings shown in the Figure 4.

Continued · 7 901846

Page 8 of the FMI FVTR18 user manual — Pressure Testing Gas Supply Piping System
Page 8 · click to enlarge
Page 8

INSTALLATION Continued

We recommend that you install a sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 6).

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 5. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.

CHECKING GAS CONNECTIONS

FMI FVTR18 — CHECKING GAS CONNECTIONS diagram (page 8)
Fig. 2
FMI FVTR18 — CHECKING GAS CONNECTIONS diagram (page 8)
Fig. 3

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.

Manufactured Fireplace Masonry Fireplace

FMI FVTR18 — CHECKING GAS CONNECTIONS diagram (page 8)
Fig. 4

Pressure Testing Gas Supply Piping System

Approved Flexible Gas Hose (if allowed by local codes)

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was con- nected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect log set and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

  • Before installing log set, make sure you have the items listed below.
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve
  • test gauge connection
  • adjustable (crescent) wrench or pliers
  • sediment trap
  • tee joint
  • pipe wrench

Figure 6 - Gas Connection * Purchase the optional CSA design-certi- fied equipment shutoff valve from your dealer. See Accessories, page 17. ** Minimum inlet pressure for purpose of input adjustment.

Damper Clamp · Sediment Trap · 8 901846

Page 9 of the FMI FVTR18 user manual — HEARTH KIT ASSEMBLY AND INSTALLATION
Page 9 · click to enlarge
Page 9

INSTALLATION Continued

5. Apply thread sealant to the 1/8" brass pipe nipple and thread it onto the mani- fold block. Tighten with a 7/16" wrench. 6. Slip the air restrictor over the 1/8" pipe nipple. Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting. Tighten with a 9/16" wrench. 7. Place the grate assembly over the burner pan. Install the rear burner bracket onto the grate with the 2 black Phillips head #10 screws provided. Do not tighten at this time (see Figure 9). 8. Install the “U” burner from the left side with the open end in the front (see Fig- ure 9). Hold the rear of the burner higher than the bracket. Slide the burner over the air restrictor fitting. Lower the rear of the burner into the slots on the burner bracket. Install the burner clip and tighten the nuts and screws. 9. Install 3/8" flare x 3/8" male pipe el- bow into the inlet of the manifold block. Install the pipe plug into the top of the manifold block. Use thread sealant.

Installation and Gas Connection 1. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant. 2. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. 3. Install the flex gas line to the gas sup- ply fitting. Carefully shape tube to at- tach to adapter fitting (see Figure 10). 4. Replace valve cover.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 7). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equip- ment shutoff valve (see Figure 7). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Burner Pan Assembly (Facing Front of Fireplace)

Figure 10 - Connecting Gas to Appliance

Figure 7 - Checking Gas Joints

HEARTH KIT ASSEMBLY AND INSTALLATION

Kit Assembly

Note: Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. 1. Remove burner inlet fitting from front burner (installed in burner pan, see Fig- ure 8). 2. Make sure ports on front burner are facing the front (open side) of burner pan. Refit if needed. 3. Using thread sealant (resistant to the action of propane/LP gas) on larger end of fitting, screw the burner inlet fitting through the hole and into the front burner (see Figure 8). Tighten using a 7/8" wrench. If using propane/LP gas, see Propane/LP Gas Conversions, page 10. 4. Apply thread sealant compound to the 3/8" male threads of the burner inlet fitting. Thread the manifold block (see Figure 8) onto the burner inlet fitting. Use the bottom hole of the block.

Figure 8 - Kit Assembly

Figure 9 - Installing Burner

Show 18 more labels / short text on this page
Gas Supply Fitting · Equipment Shutoff Valve · Gas Meter · Flex Gas Line · Rear Burner Nozzle · Air Restrictor · Pipe Nipple · Front Burner · Burner Inlet Fitting · Manifold Block · Grate · Burner Bracket · Burner Clip · Pipe Plug · Burner Pan · Pipe Elbow · Continued · 9 901846
Page 10 of the FMI FVTR18 user manual — Propane/LP Gas Conversion
Page 10 · click to enlarge
Page 10
FMI FVTR18 — OPTIONAL GA9003 SERIES ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY diagram (page 10)
Fig. 5

INSTALLATION Continued

9. Install valve cover to burner pan using screws provided. 10. Install thermocouple, pilot, and ignitor onto valve cover as shown in Figure 14. Use the provided screws. 11. Push the control rod extension onto the “D” shaped control rod through the cen- ter hole in the cover. 12. Install the position decal and control knob making sure to align the marks with the correct stop positions of the gas control. Pilot position will allow the knob to push in about 1/2". Align the decals in the pilot position.

OPTIONAL GA9003 SERIES ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY

For additional convenience and safety, or for propane/LP conversion, an optional ON/ OFF safety valve/pilot kit is available. See Accessories, page 17.

Natural Gas Installation 1. Thread the gas control valve onto the close pipe nipple (see Figure 11). Use thread sealant on the male threads of the fitting. Thread other end of the nipple into the burner manifold block. Hold the manifold block with a wrench to prevent stressing the connections to the burners. Make sure the control rod is facing the front (see Figure 11). 2. Attach the pilot gas line to the pilot out- let of the gas control valve and tighten. Connect the thermocouple to the rear of the gas control valve (see Figure 12). Do not overtighten (finger-tight plus 1/4 turn). If using propane/LP gas, see Changing Pilot Orifice, page 11. 3. Install the inlet fitting into the inlet opening of the gas control valve (see Figure 13). Use thread sealant on the male pipe threads. 4. Thread the gas supply fitting to the fire- place gas supply pipe (see Figure 10, page 9). Adjust to most convenient position. 5. Install the gas flex line to the gas supply fitting. Carefully shape tube to attach to adapter fitting. 6. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. 7. Test for leaks following instructions under Testing Burner for Leaks, page 11. 8. Retighten and adjust the location of the gas control as necessary. The gas con- trol should be level, with the control rod to the front.

Figure 14 - Installing Cover, Control Knob, and Piezo Ignitor

Figure 11 - Installing Gas Control Valve

Propane/LP Gas Conversion

To convert to propane/LP gas, the two main burner orifices and pilot orifice must be replaced.

FMI FVTR18 — Propane/LP Gas Conversion diagram (page 10)
Fig. 6 · Propane/LP Gas Conversion

Note: Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. Be sure to use the correct orifice for your unit. See chart on page 7. 1. Remove the burner inlet fitting from the front burner manifold (installed in burner pan). See Figure 15, page 11. 2. Make sure ports on front burner mani- fold are facing the front (open side) of burner pan. Refit if needed. 3. Replace front burner injector with the provided injector. See chart on page 7 and Figure 16, page 11. Using thread sealant (resistant to the action of pro- pane/LP gas) on larger end of fitting, screw the burner inlet fitting through the hole and into the burner manifold. Tighten using a 7/8" wrench.

Figure 12 - Gas Control Valve with Ther- mocouple and Pilot

Gas Control Valve Gas Inlet Fitting

Figure 13 - Installing Inlet Fitting and Gas Connector Tube

Show 15 more labels / short text on this page
Screw · Ignitor · Thermocouple · Pilot · Valve Cover · Close Pipe Nipple · Piezo Ignitor · Control Rod Extension · Burner Pan · Control Knob · Manifold Block · Gas Control Valve · Control Rod · Main Burner Orifices · 10 901846
Page 11 of the FMI FVTR18 user manual — BURNER
Page 11 · click to enlarge
Page 11

INSTALLATION Continued

TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections.

The pilot is provided with a natural gas orifice installed. For propane/LP gas you must remove it and replace it with an pro- pane/LP orifice. The hardware kit contains an propane/LP orifice with a red stripe for converting the pilot. 1. Gently loosen and remove the pilot line connection from the bracket (see Figure 17). 2. Replace the injector (see Figure 17) with the propane/LP pilot injector with the red stripe. 3. Replace and tighten the pilot line to the bracket. 4. Continue with step 3 under Natural Gas Installation, page 10.

4. Apply thread sealant compound to the 3/8" male threads of the burner inlet fitting. Thread the manifold block (see Figure 15) onto the burner inlet fitting. Use the bottom hole of the block. 5 . Apply thread sealant to the 1/8" brass pipe nipple and thread it into the mani- fold block (see Figure 15). Tighten with a 7/16" wrench. 6. Slip the air restrictor over the 1/8" pipe nipple. Apply thread sealant to the male threads and install the rear burner injec- tor provided with the GA9003 (see chart on page 7) onto the fitting. Tighten with a 9/16" wrench. Proceed with step 7, page 9 in Hearth Kit Assembly.

2. Light the burner with the shutoff valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 12). 3. Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are de- tected, shut off the gas valve immedi- ately. Tighten, or reassemble the loose connection(s) using pipe joint com- pound until burner system is leak free. 4. When the burner is tested and leak free, observe the individual tongues of flame on the burner. Note: The burner design includes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool. 5. When finished testing, turn the gas shutoff valve OFF to extinguish all flames.

Figure 17 - Installing Propane/LP Pilot Orifice

ADDING PAN MATERIAL 1. Open the bag of ash bed material (ver- miculite) and spread it evenly across the burner pan to the top. You may over- flow the front and sides of the pan to cover the entire pan and connecting hardware. 2. Open the glowing embers and evenly cover the ash bed material (vermicu- lite) in the burner pan.

Figure 15 - Kit Assembly

Injector for Natural Gas

BURNER

INLET FITTING

Figure 16 - Burner Inlet Fitting with Injectors

Show 9 more labels / short text on this page
Changing Pilot Orifice · Rear Burner Nozzle · Pilot Injector · Air Restrictor · Pipe Nipple · Front Burner · Burner Inlet Fitting · Manifold Block · 11 901846
Page 12 of the FMI FVTR18 user manual — LIGHTING INSTRUCTIONS
Page 12 · click to enlarge
Page 12

INSTALLATION Continued

OPERATING APPLIANCE

INSTALLING THE EMBER BED AND LOGS (Split Oak Sets Shown) 1. Place the ember bed (included with burner set) over log grate as shown in Figure 18. 2. Position the back log flush against back of ember bed as shown in Figure 19. 3. Place the middle layer of logs as shown in Figure 20. Notice the grove in the back log for placement of log to the far right. Adequate space should be left between logs and ember bed for flames. 4. Place the top layer of logs as shown in Figure 21.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Figure 20 - Installing Logs

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

  • WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Figure 21 - Installing Logs

Figure 18 - Installing Ember Bed

LIGHTING INSTRUCTIONS

FMI FVTR18 — LIGHTING INSTRUCTIONS diagram (page 12)
Fig. 7

1. STOP! Read the safety information, above. 2. Turn the gas shutoff valve to OFF. 3. Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Fol- low the safety information above. If you don’t smell gas, go on to the next step. 4. Light a match and lay it on top of the “U” shaped burner near the edge of the cover on the right side of the pan. 5. Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again.

Figure 19 - Installing Back log

Grate Ember Bed · 12 901846

Page 13 of the FMI FVTR18 user manual — TO TURN OFF GAS
Page 13 · click to enlarge
Page 13

OPERATING APPLIANCE Continued

OPERATING INSTRUCTIONS FOR

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. 8. Turn control knob counterclockwise

GA9003

GAS SHUTOFF VALVE OPERATION

Note: Operation instructions for GA9103 Remote Ready Valve/Pilot Kit will be included with the Kit. 1. STOP! Read the safety information, page 12. 2. Make sure equipment shutoff valve is fully open. 3. Press in and turn control knob clock- wise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! See Safety information, page 2 and Air For Combustion And Ventila- tion, pages 4 through 6. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise

to the ON position. Burner should light. If burner does not light, call a qualified service person.

Flame Adjustment

Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise

to open or clockwise to close, as necessary. Shutting Off Appliance

ON

OFF

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF PULL PUSH

ON OFF

ON FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH

Turn gas shutoff valve clockwise to the OFF position.

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

OFF

CURING LOGS

Figure 22 - Ignitor and Control Knob

  • During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time. To ensure proper curing of the logs:
  • Ignite a 2" flame and maintain it for 1 hour.
  • Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

to the PILOT position and press in. Keep control knob pressed in for five (5) seconds. Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 sec- onds. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.

Figure 23 - Thermocouple and Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance 1. Turn control knob clockwise to the PILOT position. 2. Press in and turn control clockwise

to the OFF position. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise to the PILOT position.

Show 7 more labels / short text on this page
Control Knob · Ignitor · Pilot · On Off · Thermo- couple · Pilot · 13 901846
Page 14 of the FMI FVTR18 user manual — POSSIBLE CAUSE REMEDY OBSERVED PROBLEM
Page 14 · click to enlarge
Page 14

TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set.

POSSIBLE CAUSE REMEDY OBSERVED PROBLEM

Log set is smoking/sooting excessively (Note: It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flames contact the logs. This is especially true with propane/LP gas.)

1. Poor fuel quality
1. Contact local natural or propane/LP gas company 2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked 3. Separate the logs to allow more flame passage 4. Remove any foreign items from the flame pattern and/or check for proper orifice sizing 5. Preheat flue in very cold weather
2. Fireplace venting system not drafting properly
3. Excessive flame impingement or blockage 4. Improper fuel/air mixture
5. Excessive gas supply/pressure

Burner is excessively noisy (Note: The movement and combustion of gas will create low, unavoidable levels of noise.)

1. Passage of air/gas across irregular surfaces
1. Relieve any tight bends or kinks in gas supply line

Burner flame is too low or too high

1. Incorrect gas supply or pressure 2. Blocked burner orifice or burner manifold ports 3. Improper burner orifice size
1. Check for proper gas supply pressure 2. Free burner orifice and manifold ports of any burrs, paint, or other blockage 3. Verify proper burner orifice sizing (see Figure 4, page 7)

www.desatech.com

14 901846

Page 15 of the FMI FVTR18 user manual — OBSERVED PROBLEM
Page 15 · click to enlarge
Page 15

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at pilot (GA9003 Only)

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Scrape away paint on bracket for better contact with ground on piezo ignitor 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace electrode 7. Reposition electrode
3. Bad ground on piezo ignitor
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong

When ignitor button is pressed, there is spark at pilot but no ignition (GA9003 Only)

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Adjust pilot flame for approximately 2" blue flame 6. Clean pilot (see Cleaning and Maintenance , page 17) or replace pilot assembly 7. Replace gas control
5. Pilot adjustment screw closed
6. Pilot is clogged
7. Low gas pressure

Pilot lights but flame goes out when control knob is released (GA9003 Only)

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After pilot lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local natural gas company
3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged

B) Clean pilot (see Cleaning and Mainte- nance, page 17) or replace pilot assembly

5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace control valve

Burner does not light after pilot is lit (GA9003 Only)

1. Burner orifice clogged 2. Inlet gas pressure is too low
1. Clean burner orifice 2. Contact local natural or propane/LP gas company 3. Replace burner orifice 4. Reconnect leads
3. Burner orifice diameter is too small 4. Thermocouple leads disconnected or improperly connected

Delayed ignition burner (GA9003 Only)

1. Pilot flame needs adjusting
1. Adjust pilot flame for approximately 2" blue flame 2. Replace pilot orifice set
2. Wrong pilot orifice

www.desatech.com Continued

15 901846

Page 16 of the FMI FVTR18 user manual — OBSERVED PROBLEM
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Log Set produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most log sets. If noise is excessive, contact qualified service person

Log Set produces unwanted odors

1. Log Set burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement at top of page
1. Open flue to maximum. Stop using odor causing products while log set is running
2. Locate and correct all leaks (see Checking Gas Connections , pages 8 and 9)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , pages 8 and 9) 2. Replace control valve

Gas odor during combustion

1. Gas leak. See Warning statement at top of page
2. Locate and correct all leaks (see Checking Gas Connections , pages 8 and 9)

www.desatech.com

16 901846

Page 17 of the FMI FVTR18 user manual — REMOTE READY VALVE/ PILOT KIT - GA9103 (Not Shown)
Page 17 · click to enlarge
Page 17

CLEANING AND MAINTENANCE

ACCESSORIES

PINE CONES - GA9600 (Not Shown)

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-888-2050 for information. You can also write to the ad- dress listed on the back page of this manual.

For all models. Use for additional decora- tion only. Carton of 6 Boxes (3 pine cones per box).

  • Keep the area around the log set clean and clear of debris.
  • Occasionally, you may use a soft bristle brush to clean logs.
  • Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace.

ASH BED MATERIAL (Vermiculite) - GA9700 (Not Shown)

For all models. Carton of 6.

GLOWING EMBERS - GA9900 (Not Shown)

REPLACEMENT PARTS

For all models. Use for firebox decoration only.

SILICA SAND - GA9800 (Not Shown)

EQUIPMENT SHUTOFF VALVE GA5010

For all models. Use for firebox decoration only. Carton of 6.

PARTS UNDER WARRANTY

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

Contact authorized dealers of this product . If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800- 337-2564).

LAVA ROCK - GA6066 (Not Shown)

For all models. Use for firebox decoration only.

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your fireplace
  • how fireplace was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

DECORATIVE ASH BED CONTROL COVER - DABK (Not Shown)

RECEIVER AND HANDHELD REMOTE CONTROL KIT - GHRC Series

An attractive way to cover control knob and piezo ignitor.

18" ORNAMENTAL GRATE ENHANCER - GA9310 (Not Shown)

For all models. Allows the gas log set to be turned on and off by using a hand-held remote control. Valve/Pilot Kit GA9103 must be used with this remote.

Usually, we will ask you to return the defec- tive part to the factory.

For 18" models only. Additional decoration for front grate.

PARTS NOT UNDER WARRANTY

ON/OFF SAFETY VALVE/ PILOT KIT - GA9003 (Not Shown)

24" ORNAMENTAL GRATE ENHANCER - GA9320 (Not Shown)

Contact authorized dealers of this product or Parts Central (see page 20). If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

For all models. Required for Propane/LP installation.

For 24" models only. Additional decoration for front grate.

REMOTE READY VALVE/ PILOT KIT - GA9103 (Not Shown)

  • When calling DESA International, have ready
  • model number of your fireplace
  • the replacement part number

For all models.

17 901846

Page 18 of the FMI FVTR18 user manual — FVTR18
Page 18 · click to enlarge
Page 18
FMI FVTR18 — CLEANING AND MAINTENANCE diagram (page 18)
Fig. 8
FMI FVTR18 — CLEANING AND MAINTENANCE diagram (page 18)
Fig. 9

FVTR18

18 901846

Page 19 of the FMI FVTR18 user manual — PARTS AVAILABLE — NOT SHOWN
Page 19 · click to enlarge
Page 19

PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR18

KEY PART NO. NUMBER DESCRIPTION QTY.

1 098249-01 ODS Nut 2 2 901752-02 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-01 Log Grate 1 5 098304-01 Screw, 10-16 x .38 4 6 901762-01 Burner Bracket 1 7 901754-02 Front Burner 1 8 901753-02 Burner Pan 1 9 901750-01 Nozzle 1 10 901064-05 Natural Gas Injector 1 11 901066-01 Brass Air Mixer - Natural Gas 1 12 901761-01 1/8 Hex Nipple 1 13 901760-01 Manifold Block 1 14 901751-01 Air Restrictor 1 15 901756-01 Valve Cover 1 16 901056-01 Brass Elbow Flare Fitting 1 17 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 18 101628-01 Gas Line - 10" Flex 1 19 901769-02 Ember Bed 1 20 901591-08 Top Log VCR11/FS 1 21 901528-03 Top Log CS-16/FS 1 22 901619-01 Top Log FS12Y 1 23 901612-01 Top Log FS17 1 24 901676-04 Top Log CS-13Y/FS 1 25 901530-02 Bottom Log CSB-18/FS 1 26 901759-01 Manifold Plug 1

PARTS AVAILABLE — NOT SHOWN

901036-01 RADCO GEN Rating Plate 1 901039-08 Rating Information Plate 1 901242-01 Damper Clamp 1

19 901846

Page 20 of the FMI FVTR18 user manual — FVTR24
Page 20 · click to enlarge
Page 20
FMI FVTR18 — CLEANING AND MAINTENANCE diagram (page 20)
Fig. 10
FMI FVTR18 — CLEANING AND MAINTENANCE diagram (page 20)
Fig. 11

FVTR24

20 901846

Page 21 of the FMI FVTR18 user manual — PARTS AVAILABLE — NOT SHOWN
Page 21 · click to enlarge
Page 21

PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR24

KEY PART NO. NUMBER DESCRIPTION QTY.

1 098249-01 ODS Nut 2 2 901752-01 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-02 Log Grate 1 5 098304-01 Screw, 10-16 x .38 4 6 901762-01 Burner Bracket 1 7 901754-01 Front Burner 1 8 901753-01 Burner Pan 1 9 901750-01 Nozzle 1 10 901064-01 Natural Gas Injector 1 11 901066-01 Brass Air Mixer - Natural Gas 1 12 901761-01 1/8 Hex Nipple 1 13 901760-01 Manifold Block 1 14 901751-01 Air Restrictor 1 15 901756-01 Valve Cover 1 16 901056-01 Brass Elbow Flare Fitting 1 17 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 18 101628-01 Gas Line - 10" Flex 1 19 901769-01 Ember Bed 1 20 901527-05 Top Log CS-12/FS 1 21 901528-03 Top Log CS-16/FS 1 22 901619-01 Top Log FS12Y 1 23 901540-03 Top Log CS-18/CC 1 24 901612-01 Top Log FS17 1 25 901532-02 Bottom Log CS-24/FS 1 26 901759-01 Manifold Plug 1

PARTS AVAILABLE — NOT SHOWN

901036-01 RADCO GEN Rating Plate 1 901038-04 Rating Information Plate 1 901242-01 Damper Clamp 1

21 901846

Page 22 of the FMI FVTR18 user manual — NOTES
Page 22 · click to enlarge
Page 22

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 22 901846
Page 23 of the FMI FVTR18 user manual — NOTES
Page 23 · click to enlarge
Page 23

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 23 901846
Page 24 of the FMI FVTR18 user manual — NOT A UPC
Page 24 · click to enlarge
Page 24

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY FMI VENTED GAS LOGS

DESA International warrants this product to be free from defects on burner system for two (2) years and logs for a lifetime from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

901846-01 Rev. A 04/00

NOT A UPC

Model · Date Purchased · 901846 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the FMI FVTR18

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI FVTR18

Be the first to ask — other owners or our team will answer.

Original document

FMI FVTR18 manual PDF

24 pages·1.3 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…