FOR YOUR SAFETY — Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com


Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un usually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out
WARNING: This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on
openable windows and doors and c. caulking or sealants are applied to
Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap pliances need fresh air for proper combustion and ventilation. Exhaust fans, fireboxes, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow for Firebox Location, page 7.
Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the ag gregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un confined space. This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combus tion and ventilation air. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANS Z223.1/NFPA 54,Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.

Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can sup port (volume of space) x 20 = (Maxi mum Btu/Hr the space can support) Example: 3168 cu. ft. (volume of space) x 20 = 63,360 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Gas firebox logs + Btu/Hr Total = Btu/Hr
space can support) 79,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup port. You must provide additional fresh air. Your options are as follows: A. Rework work sheet, adding the space
of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 8. B. Vent room directly to the outdoors. See
Ventilation Air from Outdoors, page 8. C. Install a lower Btu/Hr gas log heater, if
lower Btu/Hr size makes room uncon fined. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
40,000 39,000 79,000

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include at tics and crawl spaces. Follow the National Fuel Gas Code ANS Z223.1/NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo stat-controlled power vent. Heated air entering the attic will activate the power vent.
Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see option 1, Figure 3). You can also remove door into adjoining room (see option 2, Figure 3). Fol low the National Fuel Gas Code ANS Z223.1/ NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts.


Figure 3 - Ventilation Air from Inside
Figure 4 - Ventilation Air from Outdoors
NOTICE: This firebox in com bination with unvented log sets are intended for use as supplemental heat. Use along with your primary heating system. Do not install them as your primary heat source. If you have a central heating system, you may run system’s circulat ing blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use unvented logs as your primary heat source.

C. When the firebox is installed on carpet
CAUTION: Log heaters in stalled in this firebox create warm air currents. These currents move heat to wall surfaces next to fire box. Installing firebox next to vinyl or cloth wall coverings or operat ing firebox where impurities (such as, but not limited to, tobacco smoke, aromatic candles, clean ing fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
ing or other combustible material, other than wood flooring, the firebox should be installed on a metal or wood panel extend ing the full width and depth of enclosure. D. Clearances from the bottom of firebox to
the floor is 0". E. Clearances from open end of firebox to fac
ing wall shall should not be less than 36".
IMPORTANT: Vent-free gas log heaters add moisture to the air. Although this is beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6. IMPORTANT: Make sure the firebox is level. If firebox is not level, log set will not work properly. Note: Your Vanguard firebox is designed to be used in zero clearance installations. Wall or framing material can be placed against any exterior surface on the rear, sides or top of your firebox, except where standoff spacers are integrally attached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or fram ing materials. Use dimensions shown for rough openings to create the easiest installation (see Built-In or Internal Wall Firebox Installation, page 9).
0" Min. Clearance to Upper Frame/Wallboard
8" Min. 4" Min.
42" Min.
Edge of Brick Liner
0" to Wood Floor
Figure 5 - Minimum Clearance Front View
1/2" Min. Clearance to Combustibles
Carefully follow the instructions below. This will ensure safe installation. Minimum Wall and Ceiling Clearances A. Clearances from edge of liner to any
36" Minimum from Edge of Facial to Facing Wall on Open End of Firebox
combustible wall should not be less than 8" (see Figure 5). B. Clearances from top of firebox opening to
43 3/4"
4" Min. from the Perpendicular Side Wall to the Edge of Facia
the ceiling should not be less than 42".
Figure 6 - Minimum Clearance - Top View
Ceiling · 24"

Mantel Clearances for Built-In Installation If placing custom mantel above built-in fire box, you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel.
Built-In or Internal Wall Firebox Installation Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. If installing a mantel above the firebox, you must follow the clearances shown in Figure 7. Follow the instructions below to install the firebox in this manner. 1. Frame in rough opening. The firebox framing should be constructed of 2 x 4 lumber or heavier. Construct framing using dimensions shown in Figure 8 and 9, page 11. It is recommended that the framing be constructed first and the unit be placed in position. After sliding the unit into place, the flanges may be nailed to the framing before applying the wallboard to the exterior framing. 2. If the vent-free firebox is to be installed directly on carpeting, tile (other than ce ramic) or any combustible material other than wood flooring; the vent-free firebox must be installed upon a metal or wood panel extending the full width and depth of the vent-free firebox.
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projections off of the facing material.
measurements are minimum distances from top of fireplace hood to bottom of mantel shelf. These minimum clearances replace any other recommended clearances supplied with your ANS Z21.11.2 approved gas logs.
Top Frame (Combustible Material)
3" 6" 9 1/4"
Combustible Material 1 1/2" Max Thickness
7" Min.
22 3/4" Min.
Supplied Firebox Hoods Must Be Used at All Times
Figure 7 - Minimum Mantel Clearances
4" Min.
36" Min. to Facing Wall
40 1/4" Min.
Facing Wall (Base line)
43 3/4" Min.
Figure 8 - Framing for Built-In Firebox

3. If a raised platform is to be constructed, ceiling clearances must be maintained. 4. Install gas piping to firebox location. See Installing Gas Line and Connecting to Gas Supply in log set owner’s manual. 5. Carefully set firebox in front of rough opening. 6. Carefully insert firebox into rough opening. 7. Attach firebox to wall studs using nails or wood screws through holes in nailing flange (see Figure 10). Attach firebox to board base through holes in firebox bot tom (see Figure 10). IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing more than 3/8".
Nailing Flanges Nails or Wood Screws
Nails or Wood Screws
Figure 10 - Attaching Firebox to Wall Studs
Combustible material must not overlap more than 3/8" onto black metal front face. Nailing Flange
IMPORTANT: See Connecting to Gas Supply in your log set owner’s manual for details on gas hookup. Figure 11, page 12, shows the typical in stallation for the gas line. When you have determined how the gas line will run, locate one of the recessed knockouts in the fire brick floor (see Figure 12, page 12,). Firmly tap the center of the knockout with a chisel until it is released. Carefully chisel the rough edges of the hole you have made to smooth edges. This hole will line up with the hole in the metal floor.
Edge of side firebox opening
3/8" Max.
11/2" Max.
Min. from firebox edge to combustible material
8" Min. from adjacent wall to fireplace opening
Figure 9 - Framing for Built-In Firebox
Drywall · 4" · Installation, Top View

the gas line into the rear of the firebox (see Figure 11). If a sediment trap is not incorporated as a part of the gas utilization equipment, one shall be installed as close to the inlet of the equipment as practical at the time of installation, as per ANS Z223.1/NFPA 54. See Figure 14.

A manual shutoff valve, CSA certified and complying with the National Fuel Gas code, ANS Z223.1/NFPA 54, must be included within 6' of the vent-free firebox gas supply system. It may be convenient to install the gas shutoff outside the vent-free firebox enclosure where it can be accessed with a key through a wall as shown in Figure 13. Depending on the type of installation, some local codes may require you to install 2 manual shutoff valves independently accessible from both rooms. Check your local codes for applicable instal lation requirements. A 36" long 1/2" NPT SCHD 40 flexible gas connector line complying with the National Fuel Gas code ANS Z223.1/NFPA 54, may be run from the regulator to the incoming 1/2" NPT black iron gas line. You may also route the incoming 1/2" NPT black iron gas line directly to the appliance regulator. Remove the gas line cover plate from the vent-free firebox’s outer surround and route

Figure 12 - Location of Knockouts for

Gas Line Installed Through Access Hole on One Side of Firebox

Figure 13 - Typical Exterior Wall Gas
Incoming 1/2" Gas Line Permitted by Local Codes

Sediment Trap (Not Supplied)
Manual Shutoff Valve is Located Under Firebox Floor on Either Side
Figure 14 - Sediment Trap Installation
Figure 11 - Installing Gas Line and

Prepare incoming black iron gas line with Teflon tape or pipe joint compound (check with local codes as to the use of Teflon tape). Com pounds used on threaded joints of gas piping shall be resistant to the action of propane/LP and should be applied lightly to ensure excess sealant does not enter the gas line. Complete your gas installation by connecting the incoming gas line to the appliance regula tor. Secure all joints tightly with wrench but do not overtighten. If a flexible gas line is used, take care not to kink the connector.
Hard-wiring Firebox Model FBPS and FGPN can be hard-wired to the duplex outlet located inside the firebox bottom if desired. This allows the blower ac cessory to be plugged into the duplex outlet.
WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the manual shutoff gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected. DO NOT USE OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED.
Electrical Installation A model GA3500A blower system assembly is available for use with the FBPS and FGPN (-LS) vent-free firebox as an optional acces sory. This blower is designed to be installed on either side of the FBPS and FGPN(-LS) firebox, when provisions for a 120 VAC sup ply connection are made at either end of the cabinet. Use of a blower system other than those manufactured by FMI PRODUCTS, LLC voids the warranty. Electrical connections are made within the receptacle with wires that are routed through the bushing provided (see Figure 15). The re ceptacle may be relocated to either side, when necessary. However, the cover plate must be replaced over the unused access point. Be certain to properly ground the vent-free firebox using the green grounding wire.
Gas supply testing Note: This section is intended as a guide for qualified technicians installing gas to this vent-free firebox.
Gas Connection Access Hole
The appliance and its’ individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Electrical Connection Access Hole
Figure 15 - Locating Electrical Connection and Gas Connection on
Either Side of Fireplace
Cover Plates

Heat Deflective Hood installation The factory supplied heat deflective hoods must be installed inside the fireplace opening on both sides for the safe operation of the unit as shown in Figure 16. 1. Remove protective covering from hoods. 2. Position deflective hood into opening on one side of the firebox and secure to the top of the opening using screws provided. 3. Secure the ends of the hood to the firebox using two screws (provided) for each side. 4. Repeat steps 2 and 3 to install hood on the remaining side and end of the firebox. Figure 16 - Typical Hood Installation
Front Hood (Typical Each Side)
2 Screws Each End of Hood
Instructions When lit for the first time, a vent-free log heater will emit a slight odor for about an hour or two. This is a normal occurrence which is due to the “curing” of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process. Keep control compartments, logs, burners and areas surrounding the logs clean by vacuuming or brushing at least twice a year. Temporary removal of the log set may ease the cleaning of the burner and pilot assembly. In cleaning, take care not to alter the settings on the pilot assembly. See the operating instructions supplied with your vent-free log heater for additional cleaning instructions.
Installation and repair should be done by a qualified person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, pet hair, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean.
For lighting and operating this vent-free firebox, please refer to the vent-free gas logs manufacturer’s instruction manual.
Corner Post · 3 Screws (Top) · (Both Sides)

You may have further questions about installa tion, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready.
You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.
Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back page of this manual.


**These items are used on both sides of fireplace.

ModelS FBPS, FGPN AND FGPN-LS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.
KEY NO.
PART NO. DESCRIPTION QTY. 1 *** Firebox Assembly 1 2 *** Firebox Bottom 1 3 *** Firebox Top 1 4 23982 Top Spacer 4 5 26731 Deflector Hood 2 6 26740 Nailing Flange 12 7-1 02013 Side Refractory Brick Liner 1 7-2 02014 Bottom Refractory Brick Liner 1 7-3 02036 Bottom Refractory Brick Liner 1 8 24007 Side Refractory Retainer 2 9 12125 Screen 4 10 26752 Extruded Louver 2 11 26733 Lower Door Panel 2 12 14200 Receptacle 1 13 21171 Access Hole Cover 3 14 12126 Screen 1 15 26771 Extruded Louver (End) 1 16 11164 Screw, #10 x 1/2, zinc PH 24 17 11165 Screw, #10 x 5/8, zinc PH 67 18 26762 Deflector Hood (End) 1
*** Not a field replaceable part.



Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
1-866-328-4537 www.fmiproducts.com
105163-01 Rev. E 01/10