Page 1 of the FMI ES401 user manual — ELECTRIC FIREPLACE/INSERT
Page 1 · click to enlarge
Page 1

ELECTRIC FIREPLACE/INSERT

32" Model ES401 SAFETY INFORMATION AND INSTALLATION MANUAL

Patent No. 7,219,456 B1

Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction resulting in serious injury and/or property damage.

This fireplace meets the construction and safety stan dards of H.U.D. for application in manufactured homes when installed according to these instructions.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Page 2 of the FMI ES401 user manual — ELECTRIC FIREPLACE/INSERT
Page 2 · click to enlarge
Page 2
Page 2 of the FMI ES401 user manual — ELECTRIC FIREPLACE/INSERT
Page 3 of the FMI ES401 user manual — Product Dimensions
Page 3 · click to enlarge
Page 3

SAFETY

14. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids or vapors are used or stored. 15. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, elec tric shock or injury to persons. 16. Avoid the use of an extension cord be cause the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord should be No. 14 AWG minimum size and rated not less than 1875 WATTS. 17. Always use ground fault protection where required by electrical codes.

18. Always disconnect power before perform ing any cleaning, maintenance or reloca tion of heater. 19. To prevent a possible fire, do not burn wood or other materials in this heater. 20. To prevent electric shock or fire, always use a certified electrician should new circuits or outlets be required. 21. When transporting or storing heater, keep in a dry place. 22. Control panel door gets hot during heater operation. Open door by pressing on right corner. A spring magnet will disengage. Pull door down to open.

Description:32" Fireplace/Inserts Voltage:120 / 240 Watts:1500 / 3000 Amps:15 Amp / 20 Amp Grounded Circuit

Product Dimensions

33.25"

37.5"

Figure 1 - Heater Dimensions

10" · 34"

Page 4 of the FMI ES401 user manual — Locating Fireplace
Page 4 · click to enlarge
Page 4

Product Identification

FMI ES401 — Product Identification diagram (page 4)
Fig. 1 · Product Identification

Heat Vents (Behind Door)

Figure 2 - Product Identification

Unpacking and Testing

Carefully remove unit from box. Prior to per manently installing unit, test to make sure unit operates properly. Unit does not come with a power cord installed. Unit must be hard wired to either a 120/60 or 240/60 volt supply.

Locating Fireplace

Show 6 more labels / short text on this page
Control Panel Door · Backlight Control · Front Glass · Back Glass · ON/OFF Power Button · Remote
Page 5 of the FMI ES401 user manual — Installation
Page 5 · click to enlarge
Page 5

Locating Fireplace

Figure 3 illustrates a variety of ways the heater may be located in a room. The heater may be installed directly on the floor or raised on a hearth.

Framed Into Wall or Existing Fireplace

This electric fireplace can be installed in a mantel, framed into a wall or installed into an existing fireplace. If installing into a mantel, follow mantel’s assembly instructions.

Figure 3 - Heater Locations

Installation

Do not store or use gasoline or other flammable vapors in the vi cinity of this or any other heater.

WARNING - RISK OF FIRE! The power cord must not be pinched or against a sharp edge. Secure cord to avoid tripping or snagging to reduce the risk of fire, electric shock or personal injury. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over.

Installing fireplace Select a suitable location that is not suscep tible to moisture and is a safe distance from drapes, furniture and high traffic areas. Note: Follow all national and local electrical codes. This insert can be installed into either an existing fireplace or as new construction/ renovation. Installing in Mantel 1. Assemble mantel according to mantel instructions. 2. Locate mantel near a wall (or corner depending on mantel type) close to a power source. You may have to alter base boards to fit mantel flush against wall. 3. Connect fireplace to power source. Insert fireplace into front of mantel. Be careful not to scratch finish on base. Fireplace will fit flush against front of mantel. 4. Push mantel with fireplace into final location. Existing Fireplace Installation 1. Thoroughly clean out existing fireplace and hearth area. 2. Seal all drafts, vents or ash clean-outs with fiberglass insulation. Seal flue. Once sealed, close damper to stop debris from falling onto unit. 3. If existing fire box is susceptible to mois ture, cap top of chimney flue to prevent infiltration of water.

Corner Mantel Installation · Wall Mantel Installation

Page 6 of the FMI ES401 user manual — Installation
Page 6 · click to enlarge
Page 6

Installation

FMI ES401 — Installation diagram (page 6)
Fig. 2 · Installation

Note: It is strongly advised that you hire a qualified professional to undertake this step in order to prevent personal injury. Once flue is capped, chimney is no longer suitable for wood burning. Note: Do not install this unit into a fireplace that is prone to dampness, the area of installation must be dry. 4. Plan the power supply. Unit does not come with a power cord. Unit must be hard wired to either a 120/60 or 240/60 volt supply.

FMI ES401 — Installation diagram (page 6)
Fig. 3 · Installation

Figure 4 - Attaching Nailing Flange Brackets

Framing Figure 5, shows a typical framing of this heater using combustible materials. All required clearances to combustibles must be adhered to. Header height is measured from the base of the heater.

New Construction or Renovation 1. Select a location at least 3 feet (0.9 m) away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc. 2. Mark desired location on floor and store unit in a safe, dry and dust free location. 3. Frame in an opening leaving at least 1/4" (6 mm) around the edge of the unit (see Framing). Any new wiring must be done in compliance with local and national codes and other applicable regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it strongly recommended that you hire a professional to complete any such work. 4. Plan your power supply route. See step 4 of Existing Fireplace Installation, above.

Built-In Fireplace 1. Remove front panel and front glass from fireplace (see Cleaning and Maintenance, page 8). 2. Locate 3 prepunched clearance holes in each side of fireplace. Press screws through brick liner, then attach nailing flange brackets to each side of fireplace (see Figure 4).

Depth DeptHe h Length H 10.5"34"

Figure 5 - Framing Heater for New

Show 6 more labels / short text on this page
Nailing Flange Bracket · Brick Liner · Screw · Header Height · Length · Construction/Renovation
Page 7 of the FMI ES401 user manual — Finishing
Page 7 · click to enlarge
Page 7

INSTALLATION

  • Tools and building supplies required for installation:
  • Saw
  • Square
  • Pliers
  • Gloves
  • Hammer
  • Level
  • Phillips screwdriver
  • Surround
  • Framing materials
  • Electric drill/bits
  • Tape measure
  • Wall-finishing materials
  • Caulking material

Installing as Insert Once the site has been prepared, your fire place insert can be installed. 1. Make sure power switch is in the OFF position. 2. Push fireplace insert so trim is against finished mantle or wall surface.

Finishing

steel, iron, brick, tile, concrete, slate, glass or plasters or combinations thereof or have a fire rating of zero.

  • Finishing checklist
  • Power supply service must be completed prior to finishing to avoid reconstruction.
  • Grills and air openings cannot be covered in any circumstances. Note: The heater is a zero clearance fireplace and may be finished with combustible or non combustible finishing materials. When using paint or lacquer to finish the mantel, they must be heat resistant to prevent discoloration.

Combustible Finishing Material: Materials made of or surfaced with wood, compressed paper, plant fibers, plastics or any material capable of igniting and burning, whether flame proofed or not, plastered or unplastered (this includes drywall). Noncombustible Finishing Material : Ma terials which will not ignite and burn. Such materials are those consisting entirely of

Operation The controls (see Figure 6) are located behind hinged control panel door. If using heater, con trol panel door will be hot during and immedi ately after operation. Open door by pressing on right side. A spring magnet will push door forward. Pull door down to open. 1. Connect fireplace to power source. Turn on lighted power switch (see Figure 6). 2. Adjust Flame/Ember/Backlight/Heater to desired settings using the control pad on fireplace (Figure 6) or remote control (Figure 7, page 8). Figure 8, page 8, shows fireplace settings available. Default settings are circled. Press control pad or remote control buttons once and release to adjust settings. Note: When on, ember bed will lighten and darken automatically to simulate real embers.

The heater is pre-set to the following temperatures: HIGH will shut off when room reaches approximately 86° F (30° C). Medium will shut off when room reaches approximately 79° F (26° C). Low will shut off when room reaches approximately 72°F (22° C). Note: Fan on heater will continue to run for 5-7 seconds after heater has been turned off.

Ember Control Heater Control Flame Control

Heater Flame Ember Backlight

Figure 6 - Controls For Electric Fireplace

Backlight Control · Lighted Power Switch · Power

Page 8 of the FMI ES401 user manual — Cleaning and Maintenance
Page 8 · click to enlarge
Page 8

Operation

3. When using remote control, aim remote at sensor located in center of unit just

above log set. IMPORTANT: This remote control must remain within 20 feet (6 m) of fireplace to be effective. 4. When power switch is turned off, fireplace settings go back to default (see Figure 8).

FMI ES401 — Operation diagram (page 8)
Fig. 4 · Operation

HEATER Off Low Medium High

FLAME Off Low Medium High

EMBER Off Low Medium High

BACKLIGHT Off Low High

Figure 8 - Fireplace Settings (Default

Cleaning and Maintenance

FMI ES401 — Cleaning and Maintenance diagram (page 8)
Fig. 5 · Cleaning and Maintenance

To service electric fireplace it may be neces sary to remove it from the mantel or enclosure in which it is installed. Let unit cool completely before cleaning or servicing.

Cleaning Firebox 1. Open control panel door by pressing on right side. A spring magnet will push door forward. Pull door down to open. 2. Remove 2 screws holding front trim in place. Pull gently to remove trim (see Figure 9). There are magnets on the lower portion of trim (see Figure 9) 3. With gloves and safety glasses in place, remove 4 screws from glass retainer brackets (see Figure 9). 4. Carefully remove front glass and brackets (see Figure 10). 5. Using a brush vacuum attachment, gently clean compartment. 6. After cleaning compartment, replace front glass, brackets and trim.

Figure 9 - Removing Trim

FMI ES401 — Cleaning and Maintenance diagram (page 8)
Fig. 6 · Cleaning and Maintenance

Figure 10 - Removing Brackets and Front

Settings are Circled) · Glass

Page 9 of the FMI ES401 user manual — LED
Page 9 · click to enlarge
Page 9

Cleaning and Maintenance

Replacing log 1. Follow steps 1 through 4 of Cleaning Firebox, page 8. 2. Remove screws from each side of log that secure log to sides and remove log (see Figure 11). 3. Install new log using screws removed in step 2. 4. Replace front glass and brackets. 5. Replace trim.

6. Remove brackets from heater/blower (see Figure 13). Save brackets and screws. 7. To remove heater from blower, remove 4 screws (2 per side). 8. If replacing blower, remove screws from brackets on blower (see Figure 14, page 10). Install brackets to new blower. 9. Replace blower or heater. Replace screws removed in step 7. 10. Hold heater/blower with brackets in place against top panel and replace screws removed in step 5. 11. Reconnect wires to main circuit board (see Wiring Diagram, page 14). 12. Replace glass with brackets, and top panel. 13. Replace trim.

Ember LED Strip with Standoffs

Top Panel Screws Screws Securing Heater/Blower

Figure 11 - Removing Log and Ember

LED

Replacing Ember Strip 1. Follow steps 1 and 2 under Replacing Log. 2. Locate ember LED strip (see Figure 11). Disconnect wire (right side). 3. Remove ember LED strip by squeezing top of standoffs and discard. 4. Connect new ember LED strip using exist ing standoffs. 5. Reconnect wire to LED strip. 6. Follow steps 3 through 5 under Replac ing Log.

Figure 12 - Removing Top Panel and

Replacing Heater/Blower 1. Follow steps 1 and 4 of Cleaning Firebox, page 8. 2. Remove screws from around top panel of firebox (see Figure 12). 3. There are several wires attached to the top panel. Carefully lift top panel. 4. Disconnect heater/blower wires from main circuit board. 5. Remove screws holding heater/blower to top panel (see Figure 12).

Figure 13 - Removing Brackets from

Show 5 more labels / short text on this page
Screw · Log · Heater/Blower · Brackets · Heater/Blower
Page 10 of the FMI ES401 user manual — Cleaning and Maintenance
Page 10 · click to enlarge
Page 10

Cleaning and Maintenance

4. Gently push new control board onto standoffs to install. 5. Reconnect wires to main control board (see Wiring Diagram, page 14). 6. Replace glass with brackets, and top panel. 7. Replace trim

Figure 14 - Removing Heater from

Replacing Transformer 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect transformer wires from control board. 3. Remove screws and nuts from firebox surround to remove transformer (see Figure 15). 4. Remove and discard transformer. 5. Place new transformer against inside of firebox surround and replace screws and nuts removed in step 3. 6. Reconnect transformer wires to control board (see Wiring Diagram, page 14). 7. Replace glass with brackets, and top panel. 8. Replace trim

Figure 16 - Control Board

Replacing Backlight LED Strip 1. Follow steps 1 and 3 under Replacing Heater/Blower, page 9. 2. Disconnect wires from main control board. 3. Squeeze top of standoffs to remove back light LED strip and discard. 4. Place new backlight LED strip onto stand offs and push gently. 5. Connect wires to main control board (see Wiring Diagram, page 14). 6. Replace glass with brackets, and top panel.

FMI ES401 — Cleaning and Maintenance diagram (page 10)
Fig. 7 · Cleaning and Maintenance

Replacing Main Control Board 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect wires to main control board. 3. Squeeze top of standoffs to remove main control board and discard.

Show 7 more labels / short text on this page
Blower · Heater · Main Control Board · Transformer · Blower · Standoffs · Transformer
Page 11 of the FMI ES401 user manual — Cleaning and Maintenance
Page 11 · click to enlarge
Page 11

Cleaning and Maintenance

Replacing Settings Control Board 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect wires from main control board. 3. Remove screws from bracket to remove settings control board. 4. Place new settings control board into posi tion making sure each control is aligned with slot in panel. Install using screws from step 3. DO NOT overtighten. This will damage control board. 5. Reconnect wires to main control board (see Wiring Diagram, page 14). 6. Replace glass with brackets, and top panel. 7. Replace trim

5. There are several wires attached to bot tom panel. Carefully remove panel. 6. Disconnect wires from motor and LED drum assembly. 7. Remove screws from bottom panel to remove assembly. 8. If motor on assembly fails, loosen clamps (see Figure 19). Remove screws from motor. Hold universal joint while removing motor and discard. 9. Install new motor. Slide motor shaft into universal joint and tighten clamps. 10. Hold LED drum assembly in place on bottom panel and replace screws. 11. Reattach wires to motor and LED drum. Note: LED drum wires are polarity sensi tive and must be connected correctly. White wire plugs onto left terminal and red wire plugs onto right terminal. Motor wires can be connected to either terminal. 12. Replace fireplace bottom panel. Set fire place upright and replace screws. 13. Replace log, glass and brackets. 14. Reinstall fireplace and replace trim.

FMI ES401 — Cleaning and Maintenance diagram (page 11)
Fig. 8 · Cleaning and Maintenance

Figure 18 - Replacing Settings Control

Replacing Flame Generation LED 1. Follow steps 1 through 4 under Cleaning Firebox, page 8 2. Remove screws from each side of log that secure log to base and remove log (see Figure 11, page 9). 3. Remove screws from sides and back of bottom panel of firebox. 4. Gently lay unit on its back.

Screws · Board

Page 12 of the FMI ES401 user manual — Replacement Parts
Page 12 · click to enlarge
Page 12

Cleaning and Maintenance

Cleaning or Replacing back screen (Glass) 1. The glass is cleaned in the factory during assembly. During shipment, installation, handling, etc. glass surface may collect dust particles. These can be removed by buffing lightly with a clean damp cloth (water only). Glass should be completely dried with a lint free cloth or paper towel. 2. In the event of glass breakage, vacuum all remaining glass pieces with a shop vac. DO NOT VACUUM WHILE PIECES ARE HOT. Replace glass only with replacement part specifically for this heater. Never substitute material. Only fully tempered soda lime safety glass may be used on this heater.

3. To access glass to clean or replace, fol low steps 1 and 7 under Replacing Flame Generation LED, page 11. Set aside bot tom panel. 4. Using gloves, gently remove glass panel by sliding it toward you. There is a rubber bumper on each corner of glass. 5. Clean glass as instructed in step 1 or replace glass. 6. Using gloves, reinstall glass by gently sliding, smooth side toward fireplace front, into brackets on either side that hold glass in place. 7. Replace log base. 8. Follow steps 11 and 14 under Replacing Flame Generation LED, page 11.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready.

You can also visit our web site at www.fmiproducts.com. This information can be found on the fireplace's rating plate located behind the control panel door.

Replacement Parts

  • When calling, have ready:
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • purchase date Usually, we will ask you to return the part to the factory.
Page 13 of the FMI ES401 user manual — POSSIBLE CAUSE REMEDY OBSERVED PROBLEM
Page 13 · click to enlarge
Page 13

Troubleshooting

POSSIBLE CAUSE REMEDY OBSERVED PROBLEM

Fireplace turns off and will not turn on

1. Fireplace has overheated and safety devise has cause thermal switch to disconnect or home circuit breaker has opened
1. Reset switch by turning main power switch off and waiting 5 minutes then turn ing it back on or reset circuit breaker

Flame is not moving

1. Loose wiring
1. Inspect wiring for loose connections 2. Call a qualified service techni cian to replace flame motor
2. Flame motor defective

Flame is not visible

1. Wiring is loose
1. Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary

Log set and/or ember is not glowing

1. Wiring is loose
1. Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary
1. Flame motor is defective
1. Call a qualified service techni cian to replace flame motor 2. Disconnect power. Fol low steps to replace flame generation LED. Clean contacts with dry cloth.
2. Flame generation contacts dirty/obstructed

Remote control does not work

1. Low batteries
1. Replace AAA batteries in remote control 2. Aim control at sensor lo cated directly behind glass screen in center of unit just above logs 3. Replace remote control and/or sensor
2. Not aiming control cor rectly
3. Defective remote control and/or sensor

Fireplace will not come on when switch is flipped to ON

1. Control failure
1. Call a qualified service tech nician to replace control 2. Reset breaker
2. Breaker tripped

Heater does not provide heat when turned on

1. Thermal switch has been tripped
1. Turn unit off. Turn off power to unit for 5 minutes. Turn power and unit on. 2. Turn off circuit breaker that supplies electricity to unit. Wait 5 minutes then flip circuit breaker back on 3. Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary 4. Replace heater 5. Change to higher setting
2. Circuit breaker has been tripped
3. Wiring is loose
4. Heater is defective 5. Thermostat cycled off

Flame sputters/flashes

Page 14 of the FMI ES401 user manual — DPST
Page 14 · click to enlarge
Page 14

Wiring Diagram

nuts. Unplug unit

before servicing.

WARNING

SCB TF1 THM

Remote Control Sensor (Infrared)

Voltage 240V AC

Junction Box

- MTR RCS

32" and 36" BUILDER ELECTRIC FIREPLACE CONTROL DIAGRAM PCB BOARD AND FUNCTION CONTROL ASSEMBLY

M

ORG ORGGRE CYA FAN LES LBS LDA

P/N F904-0036-9000 (Rev A)

Voltage 120V AC

Junction Box

M

WHT YLW YLW YLW BRW

WHT

GREDark Green
ORGOrange
YLWYellow
BRWBrown
WHTWhite
CYACyan
BLKBlack

DPST

Show 62 more labels / short text on this page
Cover all unused · wires with tape · and install wire · White · Red · Yellow · Transformer · Thermostat · Settings · Control · Board · Dark Green · Purple · Yellow · Brown · Black · Gray · Blue · Red · Black · Motor Assembly · LED Drum/ · White · + - · Green · + · White · Black · LED Backlight Strip · Dark Green · Purple · Yellow · Brown · Black · Gray · Blue · Red · LED Ember Strip · Black · Assembly Blower · White · Cyan · Heating Element · White · Black · Green · Heater · Heater · Fuse · Electrical · Outlet · Blue · Gray · Rocker Switch · Purple · Yellow · Brown · Dark Green · Gray · Blue · Red · Black
Page 15 of the FMI ES401 user manual — Wiring Diagram
Page 15 · click to enlarge
Page 15

Accessories Purchase these accessories from your local dealer. If they can not supply these acces sories, either contact your nearest Parts Central or call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the address listed on the back

page of this manual.

Mantels W32TU - 32" Wall Mantel, Unfinished, Traditional W32TO - 32" Wall Mantel, Oak Stain, Traditional C32TU - 32" Corner Mantel, Unfinished, Traditional C32TO - 32" Corner Mantel, Oak Stain, Traditional W32CO - 32" Wall Mantel, Oak Stain, Classic C32CO - 32" Corner Mantel, Oak Stain, Classic W32DO - 32" Wall Mantel, Oak Stain, Dentil W32GO - 32" Wall Mantel, Oak Stain, Georgian C32GO - 32" Corner Mantel, Oak Stain, Georgian

Page 16 of the FMI ES401 user manual — Parts Model ES401
Page 16 · click to enlarge
Page 16

Parts Model ES401

FMI ES401 — Parts Model ES401 diagram (page 16)
Fig. 9 · Parts Model ES401
Page 17 of the FMI ES401 user manual — Parts Model ES401
Page 17 · click to enlarge
Page 17

PARTS Model ES401 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual.

KEY NO. PART NO. DESCRIPTION QTY. 1 120928-43 Blower 1 2 120928-06 Rear Glass (Screen) 1 3 120928-05 Log Set 1 4 120928-07 Flame Effect Mirror 1 5 120927-08 Handles 2 6 120928-26 Main Control Board and Standoffs (5) 1 7 120928-27 Transformer 1 8 120928-42 Heater 1 9 120927-12 Settings Control Board 1 10 120928-13 LED Drum Assembly 1 11 120927-14 Motor (Drum) 1 12 120927-15 LED Ember Strip 1 13 120927-20 Remote Control 1 14 120927-21 Remote Control Sensor 1 15 120926-32 Magnetic Catch 1 16 120927-24 ON/OFF Switch 1 17 120928-03 Front Glass 1 18 120928-02 Control Panel Door (Black) 1 19 120928-25 Top (Black) 1 20 120928-01 Front Trim 1 21 122660-01 Nailing Flange Bracket 2 22 120927-16 Back Light Strip 1 23 120928-40 Grate 1 24 120928-44 Flame Effect Mirror Bracket 2 25 120928-45 Front Glass Bracket 2 26 120928-46 Heater/Blower Bracket 2 PARTS AVAILABLE NOT SHOWN 120928-17 Wire (Flame Effect) 1 120928-18 Wire (Ember Bed) 1 120928-19 Wire (Backlight) 1 120927-23 Thermocouple 1

Page 18 of the FMI ES401 user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 18 · click to enlarge
Page 18

Page 19 of the FMI ES401 user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 19 · click to enlarge
Page 19

Page 20 of the FMI ES401 user manual — FMI PRODUCTS, LLC LIMITED WARRANTIES
Page 20 · click to enlarge
Page 20

Warranty

KEEP THIS WARRANTY

Model (located on product or identification tag)

Serial No. (located on product or identification tag)

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.

Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).

This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.

FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For information about this warranty contact:

2701 S. Harbor Blvd. Santa Ana, CA 92704

1-866-328-4537 www.fmiproducts.com

122638-01 Rev. E 09/09

Date Purchased

Ask about the FMI ES401

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI ES401

Be the first to ask — other owners or our team will answer.

Original document

FMI ES401 manual PDF

20 pages·1.3 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…