SAFETY INFORMATION AND INSTALLATION MANUAL

Patent No. 7,219,456 B1
Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction resulting in serious injury and/or property damage.
This fireplace meets the construction and safety stan dards of H.U.D. for application in manufactured homes when installed according to these instructions.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com



14. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids or vapors are used or stored. 15. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, elec tric shock or injury to persons. 16. Avoid the use of an extension cord be cause the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord should be No. 14 AWG minimum size and rated not less than 1875 WATTS. 17. Always use ground fault protection where required by electrical codes.
18. Always disconnect power before perform ing any cleaning, maintenance or reloca tion of heater. 19. To prevent a possible fire, do not burn wood or other materials in this heater. 20. To prevent electric shock or fire, always use a certified electrician should new circuits or outlets be required. 21. When transporting or storing heater, keep in a dry place. 22. Control panel door gets hot during opera tion. Open door by pressing on right side. A spring magnet will disengage. Pull door down to open.
Figure 1 - Heater Dimensions

Heat Vents (Behind Door)
Carefully remove unit from box. Prior to permanently installing unit, test to make sure unit operates properly. To do this, plug unit's power supply cord into a conveniently located 120-volt grounded outlet.

Figure 3 illustrates a variety of ways the heater may be located in a room. The heater may be installed directly on the floor or raised on a hearth.
Framed Into Wall or Existing Fireplace
This electric fireplace can be installed in a mantel, framed into a wall or installed into an existing fireplace. If installing into a mantel, follow mantel’s assembly instructions.
Figure 3 - Heater Locations
Do not store or use gasoline or other flammable vapors in the vi cinity of this or any other heater.
WARNING - RISK OF FIRE! The power cord must not be pinched or against a sharp edge. Secure cord to avoid tripping or snagging to reduce the risk of fire, electric shock or personal injury. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over.
Installing fireplace Select a suitable location that is not suscep tible to moisture and is a safe distance from drapes, furniture and high traffic areas. Note: Follow all national and local electrical codes. This insert can be installed into either an existing fireplace or as new construction/ renovation. Installing in Mantel 1. Assemble mantel according to mantel instructions. 2. Locate mantel near a wall (or corner depending on mantel type) close to a power source. You may have to alter base boards to fit mantel flush against wall. 3. Insert fireplace into front of mantel. Be careful not to scratch finish on base. Fire place will fit flush against front of mantel. 4. Plug fireplace into power source. Push mantel with fireplace into final location.
Existing Fireplace Installation 1. Thoroughly clean out existing fireplace and hearth area. 2. Seal all drafts, vents or ash clean-outs with fiberglass insulation. Seal flue. Once sealed, close damper to stop debris from falling onto unit. 3. If existing fire box is susceptible to mois ture, cap top of chimney flue to prevent infiltration of water.
Corner Installation · Mantel Installation

Note: It is strongly advised that you hire a qualified professional to undertake this step in order to prevent personal injury. Once the flue is capped, chimney is no longer suitable for wood burning. Note: Do not install this unit into a fireplace that is prone to dampness; the area of instal lation must be dry. 4. Plan the power supply. If an existing grounded outlet is near fireplace, power cord can run along front of fireplace. If cord is not long enough to reach outlet, a grounded extension cord minimum AWG No. 14 and rated to a minimum of 1875 watts, may be used. If you plan to cut or drill a hole in existing fireplace for wiring, it is best to hire a professional to do this step in order to prevent personal injury. To reduce the risk of fire, do not run power cord under rugs, carpets, etc. Arrange power supply cord away from high traffic areas where it may pose a tripping hazard.
New Construction or Renovation 1. Select a location at least 3 feet (0.9 m) away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc. 2. Mark desired location on floor and store unit in a safe, dry and dust free location. 3. Frame in an opening leaving at least 1/4" (6 mm) around the edge of the unit (see ). Any new wiring must be done in compliance with local and national codes and other ap plicable regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it strongly recommended that you hire a professional to complete any such work. 4. Plan you power supply route. See step 4 of Framing
22.5" Header Height
17.5"
8.5"
0.75" - 0.50"
Figure 4 - Framing Heater for New
Construction/Renovation

Installing as Insert Once the site has been prepared, the fireplace insert can be installed. 1. Make sure power switch is in the OFF position.
Combustible Finishing Material: Materials made of or surfaced with wood, compressed paper, plant fibers, plastics or any material capable of igniting and burning, whether flame proofed or not, plastered or unplastered (this includes drywall). Noncombustible Finishing Material : Ma terials which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters or combinations thereof or have a fire rating of zero.
The controls (see Figure 5) are located behind hinged control panel door. If using heater, con trol panel door will be hot during and immedi ately after operation. Open door by pressing on right side. A spring magnet will push door forward. Pull door down to open. 1. Plug in electric fireplace. 2. Turn on lighted power switch (see Figure 5). 3. Adjust Flame and Ember to desired set tings using the control pad on fireplace or remote control (see Figure 6). Figure 7, page 8, shows fireplace settings available. Default settings are circled. Press control pad or remote control buttons once and release to adjust settings. The heater works with a thermostat when turned on. It will shut off when room reaches approximately 86° F (30° C).
Figure 6 - Remote Control For Electric
Figure 5 - Controls For Electric Fireplace

FLAME Off Low Medium High
EMBER Off Low Medium High
Figure 7 - Fireplace Settings (Default Settings are Circled)


To service electric fireplace it may be neces sary to remove it from the mantel or enclosure in which it is installed. Let unit cool completely before cleaning or servicing.
Cleaning Firebox 1. Open control panel door by pressing on right side. A spring magnet will push door forward. Pull door down to open. 2. Remove 2 screws holding front trim in place. Pull gently to remove trim (see Figure 8). There are magnets on the lower portion of trim (see Figure 8) 3. With gloves and safety glasses in place, remove 4 screws from glass retainer brackets (2 per bracket). 4. Carefully remove front glass and brackets (see Figure 9). 5. Using a brush vacuum attachment, gently clean compartment. 6. After cleaning compartment, replace front glass, screw, bracket and trim. Figure 9 - Removing Brackets and Front
Figure 8 - Removing Trim

HEATER Off On · Glass

Replacing log 1. Follow steps 1 through 4 of Cleaning Firebox, page 8. 2. Remove screws from each side of log that secures log to base and remove log (see Figure 9, page 8). 3. Install new log using screws removed in step 2. 4. Replace front glass, bracket and screws. 5. Replace trim.
4. Disconnect heater/blower wires from main circuit board. 5. Remove screws holding heater/blower to top panel (see Figure 11). 6. Remove brackets from heater/blower (see Figure 12). Save brackets and screws. 7. To remove heater from blower, remove 4 screws (2 per side). 8. If replacing blower, remove screws from brackets on blower. Install brackets to new blower. 9. Replace blower or heater. Replace screws removed in step 7 (see Figure 13, page 10). 10. Hold heater/blower with brackets in place against top panel and replace screws removed in step 5. 11. Reconnect wires to main circuit board (see Wiring Diagram, page 12). 12. Replace top panel and screws. 13. Replace trim.
Ember LED Strip with Standoffs
Figure 10 - Removing Log and Ember
Replacing Ember Strip 1. Follow steps 1 and 2 under Replacing Log. 2. Locate ember LED strip (see Figure 10). Disconnect wire (right side). 3. Remove ember LED strip by squeezing top of standoffs and discard. 4. Connect new ember LED strip using exist ing standoffs. 5. Reconnect wire to LED strip. 6. Follow steps 3 and 4 under Replacing Log.
Figure 11 - Removing Top Panel and
Replacing Heater/Blower 1. Follow steps 1 and 2 of Cleaning Firebox, page 8. 2. Remove screws from around top panel of firebox (see Figure 11). 3. There are several wires attached to the top panel. Carefully lift top panel.
Figure 12 - Removing Brackets from


Replacing Transformer 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect transformer wires from control board. 3. Remove screws from outside of firebox surround to remove transformer (see Figure 14). 4. Remove and discard transformer. 5. Place new transformer against inside of firebox surround and replace screws removed in step 3. 6. Reconnect transformer wires to control board (see Wiring Diagram, page 12). 7. Replace top panel and screws. 8. Replace trim
Figure 15 - Control Board
Replacing Settings Control Board 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect wires from main control board. 3. Remove screws from bracket to remove settings control board. 4. Place new settings control board into posi tion making sure each control is aligned with slot in panel. Install using screws from step 3. DO NOT overtighten. This will damage control board. 5. Reconnect wires to main control board (see Wiring Diagram, page 12). 6. Replace top panel and screws. 7. Replace trim

Screws Settings Control Board Replacing Main Control Board 1. Follow steps 1 through 3 under Replacing Heater/Blower, page 9. 2. Disconnect wires to main control board. 3. Squeeze top of standoffs to remove main control board and discard. 4. Gently push new control board onto standoffs to install.

Replacing Flame Generation LED 1. Follow steps 1 through 4 under Cleaning Firebox, page 8 2. Remove screws from each side of log that secures log to base and remove log (see Figure 10, page 8). 3. Remove screws from sides and back of bottom panel of firebox. 4. Gently lay unit on its back. 5. There are several wires attached to bot tom panel. Carefully remove panel. 6. Disconnect wires from motor and LED drum assembly. 7. Remove screws from bottom panel to remove assembly. 8. If motor on assembly fails, loosen clamps (see Figure 17). Remove screws from motor. Hold universal joint while removing motor and discard. 9. Install new motor. Slide motor shaft into universal joint and tighten clamps. 10. Hold LED drum assembly in place on bottom panel and replace screws. 11. Reattach wires to motor and LED drum. Note: LED drum wires are polarity sensi tive and must be connected correctly. White wire plugs onto left terminal and red wire plugs onto right terminal. Motor wires can be connected to either terminal.
Cleaning or Replacing back screen (Glass) 1. The glass is cleaned in the factory during assembly. During shipment, installation, handling, etc. glass surface may collect dust particles. These can be removed by buffing lightly with a clean damp cloth (water only). Glass should be completely dried with a lint free cloth or paper towel. 2. In the event of glass breakage, vacuum all remaining glass pieces with a shop vac. DO NOT VACUUM WHILE PIECES ARE HOT. Replace glass only with replacement part specifically for this heater. Never substitute material. Only fully tempered soda lime safety glass may be used on this heater. 3. To access glass to clean or replace, follow steps 1 and 7 under Replacing Flame Generation LED. Set aside bottom panel. 4. Remove screws securing log base to unit. Carefully remove log base from unit. 5. Using gloves, gently remove glass panel by sliding it toward you. There is a rubber bumper on each corner of glass. 6. Clean glass as instructed in step 1 or replace glass. 7. Using gloves, reinstall glass by gently sliding, smooth side toward fireplace front, into brackets on either side that hold glass in place. 8. Replace log base. 9. Follow steps 11 and 14 under Replacing Flame Generation LED.
White Wire Red Wire
Technical Service You may have further questions about instal lation, operation or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328- 4537. When calling please have your model and serial numbers of your heater ready. This information is located on the inside of the control panel door (Figure 2, page 4). You can also visit our web site at www.fmiproducts.com.
Figure 17 - Flame Generation LED Drum

Purchase these accessories from your local dealer. If they can not supply these accesso ries, call FMI PRODUCTS, LLC at 1-866-328- 4537 for information. You can also write to the address listed on back this manual.
21" Wall Mantels with Base and Trim W21TU - 21" Wall Mantel, Unfinished, Traditional W21TO - 21" Wall Mantel, Oak Stain, Traditional
21" Corner Mantels with Base and Trim C21TU - 21" Corner Mantel, Unfinished, Traditional C21TO - 21" Corner Mantel, Oak Stain, Traditional
WBL21.PCB
1 V21 4
1 SCB 4
19" 21" 23" FIREPLACE CONTROL DIAGRAM
120V/60HZ (12V+12V)/700MA
TF1 TF
PCB BOARD AND FUNCTION CONTROL ASSEMBLY
TRANSFORMER
P/N FF203-0014-9000 (Rev. A)
BLK WHT RED
WHITE
BRW BLU BRW LDA MTR LDS RCS THM SCL 120V/650W*2 120V/14W 24V/15W 120V/4W 24V/1W
BLACK
WHITE
BLACK
BLOWER
SCARLET
BLACK
D
BROWN
HEATER
Syn. MOTOR
BROWN
THERMOCOUPLE
HEATER
REMOTE SENSOR
THERMOSTAT
LED
POWER CORD SETS
HEATER/BLOWER
ASSEMBLY
MODEL
LED EMBER STRIP
MF500

Fireplace turns off and will not turn on
Flame is not moving
Flame is not visible
Log set and/or ember is not glowing
Remote control does not work
Fireplace will not come on when switch is flipped to ON
Heater does not provide heat when turned on
Flame sputters/flashes



PARTS Models CGEF23B and vef21b This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual.
KEY NO. PART NO. DESCRIPTION QTY. 1 120925-30 Blower 1 2 120926-06 Rear Glass (Screen) 1 3 120926-05 Log Set 1 4 120926-07 Flame Effect Mirror 1 5 120926-32 Magnetic Catch 1 6 120926-09 Main Control Board and Standoffs (5) 1 7 120927-10 Transformer 1 8 120927-11 Heater 1 9 120926-12 Settings Control Board 1 10 120926-13 LED Drum Assembly 1 11 120927-14 Motor (Drum) 1 12 120926-15 LED Ember Strip 1 13 120926-20 Remote Control 1 14 120927-21 Remote Control Sensor 1 15 120927-22 Power Cord 1 16 120927-24 ON/OFF Switch 1 17 120926-03 Front Glass 1 18 120926-02 Control Panel Door (Black) 1 19 120926-25 Top (Black) 1 20 120926-04 Front Trim 1 PARTS AVAILABLE NOT SHOWN 120926-17 Wire (Flame Effect) 1 120926-18 Wire (Ember Bed) 1 120927-23 Thermocouple 1

Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
1-866-328-4538 www.fmiproducts.com
120926-26 Rev. C 09/09
Date Purchased