www .fmiproducts.com 124979-01C 2 W ARNING: Improper alteration, service or maintenance can cause .
www .fmiproducts.com 124979-01C 3 DANGER: Carbon monoxide Early signs of carbon monoxid e poisoning resemble the u, with headaches, dizziness or nausea.
www .fmiproducts.com 124979-01C 4 PRODUCT IDENTIFICA TION Ignitor Button Screen Fireplace Cabinet Log Control Knob Figure 1 - V ent-Free Compact Dual Flame Fireplace Hood Fireplace Cabinet Logs Ignitor Button Remote Control (Optional) Control Knob Hood OPTIONAL REMO TE CONTROL A CCESSORIES SAFETY Continued 5.
www .fmiproducts.com 124979-01C 5 LOCAL CODES Install and use replace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFP A 54 *. *Available from: American National Standards Institute, Inc.
www .fmiproducts.com 124979-01C 6 strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efcient, your home needs to breathe.
www .fmiproducts.com 124979-01C 7 AIR FOR COMB USTION AND VENTILA TION Continued All spaces in homes fall into one of the three following ventilation classications: 1. Unusually Tight Construction 2. Unconned Space 3. Conned Space The infor matio n on pages 6 throu gh 8 will help you classif y your space and provide adequa te ventilation.
www .fmiproducts.com 124979-01C 8 AIR FOR COMB USTION AND VENTILA TION Continued The space in the previous example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup- port. Y ou must provide additional fresh air .
www .fmiproducts.com 124979-01C 9 INST ALLA TION IMPORT ANT : Vent-free replaces add mois - ture to the air. Although this is benecial, installing replace in rooms without enough ventilation air may cause mildew to form from too much moisture.
www .fmiproducts.com 124979-01C 10 W ARNING: Maintain the minimum clearances shown .
www .fmiproducts.com 124979-01C 11 INST ALLA TION Continued 3. Instal l gas piping to repl ace loca tion . This installation includes an approved exible gas line (if allowed by local codes) after the equipment shutoff valve. The exible gas line must be the last item installed on the gas piping.
www .fmiproducts.com 124979-01C 12 15" 18" 21" 23" 2 1 / 2 " 6" 8" 10" Note: A ll vertical measurements are from top of fireplace opening to bottom of mantel shelf.
www .fmiproducts.com 124979-01C 13 Inst allati on must include an equipmen t shut off val ve, uni on and plu gged 1/8" NPT tap. Loc ate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14). IMPORT ANT : Install equipment shutoff valve in an accessi ble location.
www .fmiproducts.com 124979-01C 14 INST ALLA TION Continued We recommend that you install a sediment trap in supply line as shown in Figure 14, page 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater .
www .fmiproducts.com 124979-01C 15 INST ALLA TION Continued CAUTION: Make sure exter- .
www .fmiproducts.com 124979-01C 16 W ARNING: Read and fol - .
www .fmiproducts.com 124979-01C 17 INST ALLA TION Continued W ARNING: Read and fol - .
www .fmiproducts.com 124979-01C 18 .
www .fmiproducts.com 124979-01C 19 • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 8. Slig ht ly pus h in and turn con tr ol kn ob coun - terclockwise to the ON position.
www .fmiproducts.com 124979-01C 20 INSPECTING B URNERS Check pilot ame pattern and burner ame patterns often. Figure 29 shows a correct pilot ame pattern. Figure 30 shows an incorrect pilot ame pat - tern.
www .fmiproducts.com 124979-01C 21 We also recommend that you keep the burner tube and pilot assemb ly clean and free of dust and dirt. T o clean these parts we recommend using compressed air no greater than 30 PSI. Y our local computer store, hardware store or home center may carry compressed air in a can.
www .fmiproducts.com 124979-01C 22 TROUBLESHOO TING .
www .fmiproducts.com 124979-01C 23 1 . Control knob not fully pressed in 2. Contro l knob not pressed in long enough 3. Safety inter lock syste m has been triggered 4. Equi pme nt shuto f f valv e not fully open 5 .
www .fmiproducts.com 124979-01C 24 TROUBLESHOO TING Continued 1. Residues from manufac- turing processes and log curing 2. Not enough air 3. Gas regulator defective 1. Turning control knob to HI position when burner is cold 2.
www .fmiproducts.com 124979-01C 25 TROUBLESHOO TING Continued .
www .fmiproducts.com 124979-01C 26 8 8 14 14 14 14 14 14 14 1 9 10 10 16 17 10 6 3 1 1 12 13 1 1 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 19 P ARTS .
www .fmiproducts.com 124979-01C 27 1 ** Outer Casing T op • 1 2 ** Bafe • 1 3 ** Outer Casing .
www .fmiproducts.com 124979-01C 28 P ARTS .
www .fmiproducts.com 124979-01C 29 P ARTS REMOTE-READY MODELS This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.
www .fmiproducts.com 124979-01C 30 SPECIFICA TIONS • Rating (V ariable): 17,000/26,000 Btu/Hr • T ype Gas: Propane/LP • Ignition: Piezo • Manifold Pressure: 8" W .C. • Inlet Gas Pressure (in.
www .fmiproducts.com 124979-01C 31 ACCESSORIES THERMOST A T -CONTROLLED Provides better heat distribu - tion. Makes replace more efcient.
124979-01 Rev . C 06/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any pa.
An important point after buying a device FMI CDCFPRB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought FMI CDCFPRB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data FMI CDCFPRB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, FMI CDCFPRB you will learn all the available features of the product, as well as information on its operation. The information that you get FMI CDCFPRB will certainly help you make a decision on the purchase.
If you already are a holder of FMI CDCFPRB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime FMI CDCFPRB.
However, one of the most important roles played by the user manual is to help in solving problems with FMI CDCFPRB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device FMI CDCFPRB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center