UNVENTED (VENT-FREE) Gas Compact Classic Hearth®

DUAL BURNER Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL

FMI CDCFPRB — TM Comfort Comfort diagram (page 1)
Fig. 1 · TM Comfort Comfort

PFS ®

US

Shown with Optional Cabinet Mantel/Hearth Base Accessory

Remote-Ready Models CDCFPRB, CDCFNRB, CDCFPRB-1,

CDCFNRB-1

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Page 2 of the FMI CDCFPRB user manual — Safety
Page 2 · click to enlarge
Page 2

Table of Contents Safety 2 Product Identification 4 Optional Remote Control Accessories 4 Local Codes 5 Product Features 5 Unpacking 5 Hood Assembly 6 Air for Combustion and Ventilation 6 Installation 9 Operation 18

Inspecting Burners 20 Cleaning and Maintenance 20 Wiring Diagram 21 Troubleshooting 22 Parts 26 Specifications 30 Replacement Parts 30 Service Hints 30 Technical Service 30 Accessories 31 Warranty Back Page

Safety

This appliance may be in- stalled in an aftermarket,* permanently located, manufactured (mobile) home, where not prohib- ited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer
Page 3 of the FMI CDCFPRB user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 3 · click to enlarge
Page 3

SAFETY

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

DANGER: Carbon monoxide poisoning may lead to death!

Fireplace front and screen be- come very hot when running heater. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than oth- ers. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor- making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is closed before running fireplace.

Keep the appliance area clear and free from combustible ma- terials, gasoline and other flam- mable vapors and liquids.

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This fireplace shall not be installed in a bedroom or bathroom.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Page 4 of the FMI CDCFPRB user manual — Optional Remote Control Accessories
Page 4 · click to enlarge
Page 4

SAFETY Continued 5. Do not use this fireplace as a wood-burn- ing fireplace. Use only the logs provided with the fireplace. 6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. 7. This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fire- place and call a qualified service person. Note: During initial operation, slight smok- ing could occur due to log curing and fire- place burning manufacturing residues. 8. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 20. 9. Before using furniture polish, wax, carpet cleaner or similar products, turn fireplace off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 10. This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fire- place if not enough fresh air is available. See Air for Combustion and Ventilation,

  • page 6. If fireplace keeps shutting off, see Troubleshooting, page 21. 11. Do not run fireplace
  • where flammable liquids or vapors are used or stored.
  • under dusty conditions. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place any objects in the fireplace or on logs. 14. Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water. 15. Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. 16. Operating fireplace above elevations of 4,500 feet could cause pilot outage. 17. Do not operate fireplace if log is broken. Do not operate fireplace if log is chipped (dime-sized or larger). 18. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity. 19. Provide adequate clearances around air openings.

Product Identification

FMI CDCFPRB — Product Identification diagram (page 4)
Fig. 2 · Product Identification
FMI CDCFPRB — Product Identification diagram (page 4)
Fig. 3 · Product Identification

Figure 1 - Vent-Free Compact Dual Flame Fireplace

Optional Remote Control Accessories

There is are two optional remote control that can be purchased separately for Remote- Ready Models:

  • wall switch
  • hand-held ON/OFF remote
  • wall thermostat
  • hand-held thermostat remote See Accessories, page 31.
Show 7 more labels / short text on this page
Hood · Hood · Screen · Logs · Ignitor Button · Log · Control Knob
Page 5 of the FMI CDCFPRB user manual — Local Codes
Page 5 · click to enlarge
Page 5

Local Codes Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.

FMI CDCFPRB — Local Codes diagram (page 5)
Fig. 4 · Local Codes

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

Product Features Safety Pilot This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Piezo Ignition System This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries or other sources to light fireplace.

Unpacking 1. Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time. 2. Remove all protective packaging applied to fireplace for shipment. 3. Make sure your fireplace includes one hardware packet. 4. Check fireplace for any shipping damage. If fireplace is damaged, call FMI PROD- UCTS, LLC at 1-866-328-4537. Please do not return it to the store.

1. Remove screws from top louver and carefully remove louver (see Figure 2). 2. Remove ceramic brick liners with protective packaging. The brick liners will be installed later. 3. Remove yellow sticker from top of firebox. 4. Replace top louver using screws removed in step 1.
FMI CDCFPRB — Local Codes diagram (page 5)
Fig. 5 · Local Codes

Figure 2 - Removing Brick Liners

Batterymarch Park · Quincy, MA 02269

Page 6 of the FMI CDCFPRB user manual — Air for Combustion and Ventilation
Page 6 · click to enlarge
Page 6

Hood Assembly

FMI CDCFPRB — Hood Assembly diagram (page 6)
Fig. 6 · Hood Assembly
6. Insert screws as shown in Figure 4. Tighten screws firmly.
FMI CDCFPRB — Hood Assembly diagram (page 6)
Fig. 7 · Hood Assembly
  • Tools Required:
  • Phillips screwdriver
  • slotted screwdriver
  • 5/16" hex wrench
  • scissors 1. If equipped, lift fireplace screen up and pull out to remove (see Figure 3). Set screen aside until installation has been completed. 2. Cut two plastic straps to remove log from firebox cavity. Set log aside. 3. An optional blower is available. See Accessories, page 31. Install optional blower now. Follow installation instructions provided with blower. 4. Locate four black Phillips sheet metal screws in hardware packet. 5. Slide hood between louver and firebox top and align screw holes.

Figure 3 - Removing and Installing Screen

FMI CDCFPRB — Hood Assembly diagram (page 6)
Fig. 8 · Hood Assembly

Figure 4 - Assembling Hood

Air for Combustion and Ventilation

FMI CDCFPRB — Air for Combustion and Ventilation diagram (page 6)
Fig. 9 · Air for Combustion and Ventilation

strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap- pliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

WARNING: This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.

Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather

Page 7 of the FMI CDCFPRB user manual — AIR FOR COMBUSTION AND VENTILATION
Page 7 · click to enlarge
Page 7

AIR FOR COMBUSTION AND VENTILATION

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 6 through 8 will help you classify your space and provide adequate ventilation. Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un- usually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out-

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with door- less passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support (volume of space) x 20 = (Maxi- mum Btu/Hr the space can support) Example: 1792 cu. ft. (volume of space) x 20 = 35,840 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace Btu/Hr Total Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used Btu/Hr (maximum space can support) Btu/Hr (actual amount used) Example: 35,840 Btu/Hr (maximum the

side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on

openable windows and doors and c. caulking or sealants are applied to

areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings. If your home meets all of these three criteria, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location.

Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

30,000 + 10,000 = 40,000

space can support) 40,000 Btu/Hr (actual amount of Btu/Hr used)

Page 8 of the FMI CDCFPRB user manual — VENTILATION AIR
Page 8 · click to enlarge
Page 8

AIR FOR COMBUSTION AND VENTILATION

The space in the previous example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup- port. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an

Ventilation Grills Into Adjoining Room,

Or Remove Door into Adjoining

adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See

Ventilation Air From Outdoors. C. Install a lower Btu/Hr fireplace, if lower Btu/

Hr size makes room unconfined. If the actual Btu/Hr used is less than the maxi- mum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Figure 5 - Ventilation Air from Inside

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo- stat-controlled power vent. Heated air entering the attic will activate the power vent.

FMI CDCFPRB — AIR FOR COMBUSTION AND VENTILATION diagram (page 8)
Fig. 10

VENTILATION AIR

FMI CDCFPRB — VENTILATION AIR diagram (page 8)
Fig. 11

Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 5). You can also remove door into adjoining room (see option 3, Figure 5). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 6 - Ventilation Air from Outdoors

Show 9 more labels / short text on this page
12" · Ventilation · Grills Into Adjoining · Room, Option 1 · Option 2 · Room, Option · 12" · Building · Outlet Air
Page 9 of the FMI CDCFPRB user manual — Installation
Page 9 · click to enlarge
Page 9

IMPORTANT: Vent-free fireplaces add mois- ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6. Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing ma- terial can be placed directly against any exterior surface on the rear, sides or top of your fireplace, except where standoff spacers are integrally at- tached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials. Note: When installing fireplace directly on carpeting, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace. Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 10).

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

  • WARNING: Never install the fireplace
  • in a bedroom or bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing or other flammable objects are less than 36" from the front, top or sides of the fireplace
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas

CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

  • INSTALLATION ITEMS Before installing fireplace, make sure you have the items listed below.
  • external regulator (supplied by installer, for propane/LP units only)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection*
  • ground joint union
  • sediment trap
  • tee joint
  • pipe wrench * An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer. See Accessories , page 31.
Page 10 of the FMI CDCFPRB user manual — Fireplace Clearances
Page 10 · click to enlarge
Page 10

Fireplace Clearances

B. Clearances from the top of the fireplace

opening to the ceiling should not be less than 36". C. For mantel clearances, see Figure 11 on

page 12.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Top 36", Left and Right Sides 6",

If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 31). If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 10 to secure your fireplace into the wall.

Bottom and Rear 0", Front 36"

  • CAUTION: If you install the fireplace in a home garage
  • fireplace pilot and burner must be at least 18" above floor.
  • locate fireplace where moving vehicle will not hit it.

*Minimum 16" from Side Wall

Figure 7 - Minimum Clearance for

Built-In Fireplace Installation Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. Trim will extend past sides of fireplace approximately 1/2". This will cover the rough edges of the wall opening. If installing a built- in mantel above the fireplace, you must follow the clearances shown in Figure 11, page 12. Follow the instructions below to install the fireplace in this manner.

  • For convenience and efficiency, install fireplace
  • where there is easy access for operation, inspection and service
  • in coldest part of room An optional blower kit is available from your dealer. See Accessories, page 31. If planning to use blower, follow instructions provided with blower for power source.
ActualFraming Height26"26 7/8" Front Width26 3/4"26 7/8" Depth14 1/4"15 1/4"

Minimum Clearances For Side Combustible Material, Side Wall and Ceiling A. Clearances from the side of the fireplace

cabinet to any combustible material and wall should follow diagram in Figure 6. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This com- bustible material must be 4" from the side of the fireplace opening (see Figure 7).

1. Frame in rough opening. Use dimensions shown in Figure 8, page 11, for the rough opening. If installing in a corner, use dimensions shown in Figure 9, page 11, for the rough opening. The height is 26 7 / 8 " which is the same as the wall opening above.

Example · * · Combustible to Wall

Page 11 of the FMI CDCFPRB user manual — 15 1 / 4 "
Page 11 · click to enlarge
Page 11
2. If installing GA3450TA blower accessory, do so at this time. Follow instructions included with blower accessory. Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installation (see Accessories, page 31). Use only approved three-wire electrical wiring.

3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not installed hood, follow instructions on page 6. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Connecting Equipment Shutoff Valve to Heater Control, page 14. 7. Bend four nailing flanges on outer casing with pliers (see Figure 10). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Connections, page 14. 10. If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim acces- sory for attaching trim. IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top edge of the firebox. Combustible materi- als should never overlap the firebox front facing.

15 1 / 4 "

26 7 / 8 "

26 7 / 8 "

Figure 8 - Rough Opening for Installing

435/16" 305/8"

Nails or Wood Screws

611/4" 267/8"

Figure 9 - Rough Opening for Installing

Figure 10 - Attaching Fireplace to Wall

Show 5 more labels / short text on this page
Wall Studs · in Wall · Nailing Flanges · in Corner · Studs
Page 12 of the FMI CDCFPRB user manual — Installation
Page 12 · click to enlarge
Page 12
  • NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
  • raise the mantel to an acceptable height
  • remove the mantel

Removing Upper Louver To install mantel or blower accessory, you must first remove the upper louver. 1. Lift screen off fireplace and remove log set if installed. 2. Remove 4 screws from upper louver (see Figure 12). Save these screws. 3. Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside. 4. Open lower louver door by swinging door down (see Figure 12).

Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between man- tel shelf and top of fireplace opening.

FMI CDCFPRB — Installation diagram (page 12)
Fig. 12 · Installation
FMI CDCFPRB — Installation diagram (page 12)
Fig. 13 · Installation

Figure 12 - Removing Top Louver and

10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.

OPTIONAL MANTEL Installation Refer to instructions provided with the mantel for assembly instructions.

Installing Optional Blower Accessory GA3450TA Refer to instructions provided with the blower for assembly instructions.

Figure 11 - Minimum Mantel Clearances

Opening Bottom Louver · for Built-In Installation

Page 13 of the FMI CDCFPRB user manual — Continued CONNECTING TO GAS SUPPLY
Page 13 · click to enlarge
Page 13

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

Continued CONNECTING TO GAS SUPPLY

Propane/ LP Supply Tank External Regulator with Vent Pointing Down

Figure 13 - External Regulator With Vent

Equipment Shutoff Valve With 1/8" NPT Tap*

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres- sure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP From External Regulator (11" W.C.** to 14" W.C. Pressure) Natural From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Approved Flexible Gas Line

Pipe Nipple Cap Tee Joint

Figure 14 - Gas Connection

* Purchase the optional equipment shutoff valve from your dealer. See Accessories, page 31.

Pointing Down · 3" Minimum · Sediment Trap

Page 14 of the FMI CDCFPRB user manual — CHECKING GAS CONNECTIONS
Page 14 · click to enlarge
Page 14
FMI CDCFPRB — Installation diagram (page 14)
Fig. 14 · Installation

We recommend that you install a sediment trap in supply line as shown in Figure 14, page 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

  • CONNECTING equipment shutoff valve to heater control Installation Items Needed
  • Phillips screwdriver
  • sealant (resistant to propane/LP gas, not provided) 1. Open lower louver (see Figure 15).

Figure 15 - Flexible Gas Line Location

FMI CDCFPRB — Installation diagram (page 14)
Fig. 15 · Installation

Flexible Gas Line from Fireplace Gas Regulator Provided With Fireplace

Propane/LP To External Regulator Natural GAS To Gas Supply

Figure 16 - Attaching Flexible Gas Line

2. Route flexible gas line, included, from fireplace control to equipment shutoff valve through side access holes in outer casing. 3. Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Figure 16).

to Equipment Shutoff Valve

CHECKING GAS CONNECTIONS

4. Check all gas connections for leaks. See Checking Gas Connections, below. Feed flexible gas line into fireplace. Make sure the entire flexible gas line is in fireplace.
Show 4 more labels / short text on this page
Flexible Gas Line · (Remote-Ready Unit Shown) · To Control Valve · Equipment Shutoff Valve
Page 15 of the FMI CDCFPRB user manual — Installation
Page 15 · click to enlarge
Page 15

pane/LP supply to equipment shutoff valve for propane/LP (see Figures 18 or 19). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once.

FMI CDCFPRB — Installation diagram (page 15)
Fig. 16 · Installation

Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Fig- ure 17). 2. Open main gas valve located on or near gas meter for natural gas or open pro- pane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figures 18 or 19). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operation, page 18). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 19.

Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equip- ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 4. Check all joints of gas supply piping sys- tem. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect fireplace and equipment shutoff valve to gas supply. Check recon- nected fittings for leaks.

FMI CDCFPRB — Installation diagram (page 15)
Fig. 17 · Installation

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 17). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from gas meter to equip- ment shutoff valve for natural gas or pro-

Figure 18 - Checking Gas Joints

FMI CDCFPRB — Installation diagram (page 15)
Fig. 18 · Installation

Figure 19 - Checking Gas Joints

Figure 17 - Equipment Shutoff Valve

Show 8 more labels / short text on this page
Equipment Shutoff Valve · Gas Control Valve · (Propane/LP Only) · Gas Control Valve · Equipment Shutoff Valve · Open · (Natural Gas Only) · Closed
Page 16 of the FMI CDCFPRB user manual — Installation
Page 16 · click to enlarge
Page 16
FMI CDCFPRB — Installation diagram (page 16)
Fig. 19 · Installation
6. Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 24). 7. Install base onto wall with provided screws.

1. Remove jumper wire from control valve (see Figure 20). 2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 22. 3. Route the 25 ft. wire to a convenient loca- tion to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened. The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace or heat and air conditioning ducts. 4. Gently remove cover of thermostat from base. Grasp sides of cover firmly and pull to separate from base. 5. Feed electrical wires through rectangular slots on each side of base (see Figure 23).

Feed wires through rectangular slots

FMI CDCFPRB — Installation diagram (page 16)
Fig. 20 · Installation

Figure 24 - Thermostat Base Terminals

“W” and “R”

Page 17 of the FMI CDCFPRB user manual — Installation
Page 17 · click to enlarge
Page 17
8. Move temperature adjustment back and forth to insure the bimetal is free from restrictions. 9. Replace cover onto base. (Upon installation, thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation). 10. Set temperature adjustment to desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

INSTALLING LOG SET AND SCREEN 1. Remove log packaging material and discard packaging. Gently place log over burner (see Figure 25). Do not allow log to contact flame. If flame contacts log, soot will be created. 2. Reattach screen by placing notches in screen frame over shoulder screws and pushing down.

FMI CDCFPRB — Installation diagram (page 17)
Fig. 21 · Installation
1. Remove jumper wire from control valve (see Figure 20, page 16). 2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect other terminal to the “THTP” terminal on control valve. See Figure 22. 3. Route the 25 ft. wire to a convenient location to mount your wall switch (no outside walls).
FMI CDCFPRB — Installation diagram (page 17)
Fig. 22 · Installation
Page 18 of the FMI CDCFPRB user manual — LIGHTING INSTRUCTIONS
Page 18 · click to enlarge
Page 18

operation

FOR YOUR SAFETY READ BEFORE LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the pi- lot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the ap-

  • pliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the

1. STOP! Read the safety information. 2. Make sure equipment shutoff valve is fully open. 3. Press in and turn control knob clockwise to the OFF position (see Figure 36. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step. 5. Press in and turn control knob counter- clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 26, page 19). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part

has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

Page 19 of the FMI CDCFPRB user manual — Optional GWMS2 Wall
Page 19 · click to enlarge
Page 19

Operation Continued

  • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 8. Slightly push in and turn control knob counterclockwise to the ON position. 9. Set flame adjustment knob to any level between HI and LO. 10. To leave pilot lit and shut off burners only, turn control knob clockwise to PILOT position. If using optional hand-held remote, use remote control manual OFF button.

TO TURN OFF GAS

TO APPLIANCE Shutting Off Fireplace 1. Turn control knob clockwise to the OFF position. 2. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery. 3. Close equipment shutoff valve (see Figure 17, page 15).

FMI CDCFPRB — TO TURN OFF GAS diagram (page 19)
Fig. 23

PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 17. 2. Press control knob and light pilot with match. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions.

Figure 26 - Control Knob and Ignitor Button Location (Shown as Supplied -

Optional GWMT1 Wall mounted Thermostat Set the temperature adjustment on wall ther- mostat to the desired setting. The thermostat has been electronically calibrated at the fac- tory and requires no adjustment or leveling. Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper opera- tion. See installation instructions on pages 16 and 17.

FMI CDCFPRB — TO TURN OFF GAS diagram (page 19)
Fig. 24

Optional GWMS2 Wall

Mounted SWITCH This wall switch works just like the conven- tional light switch. Flip switch up for on and down for off. Note: Make sure that this switch is not in a posi- tion to be mistaken for a light switch. This may result in the fireplace being inadvertently turned on without the proper precautions being taken. See installation instructions on page 17.

No Control Options)

Page 20 of the FMI CDCFPRB user manual — Cleaning and
Page 20 · click to enlarge
Page 20
FMI CDCFPRB — Inspecting Burners diagram (page 20)
Fig. 25 · Inspecting Burners
  • Inspecting Burners Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down. If pilot flame pattern is incorrect, as shown in Figure 30
  • turn fireplace off (see To Turn Off Gas to Appliance , page 19.
  • see Troubleshooting , page 22. Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Figure 32 - Incorrect Burner Flame

Cleaning and

Maintenance

FMI CDCFPRB — Cleaning and diagram (page 20)
Fig. 26 · Cleaning and

Figure 29 - Correct Pilot Flame Pattern

Figure 30 - Incorrect Pilot Flame Pattern

  • BURNER FLAME PATTERN Figure 31 shows a correct burner flame pattern. Figure 32 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge. Note: When using the fireplace the first time, the flame will be orange for approximately one hour until the log cures. If burner flame pattern is incorrect, as shown in Figure 32
  • turn fireplace off (see To Turn Off Gas to Appliance , page 19.
  • see Troubleshooting , page 22.

Burner Orifice Holder and Pilot Air Inlet Hole The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have fireplace inspected yearly by a qualified service person.

Show 7 more labels / short text on this page
Pattern · Pilot Burner · Thermocouple · (Propane/LP Remote-Ready Shown) · Pilot Burner · Thermocouple · (Propane/LP Remote-Ready Shown)
Page 21 of the FMI CDCFPRB user manual — TPTH TP
Page 21 · click to enlarge
Page 21

CLEANING AND MAINTENANCE

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could dam- age the pilot assembly. 1. Shut off unit including pilot. Allow unit to cool for at least 30 minutes. 2. Inspect burner, pilot and primary air inlet holes on orifice holder for dust and dirt (see Figure 33). 3. Blow air through the ports/slots and holes in the burner. 4. Check the orifice holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the orifice holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air

inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figures 34 or 35 depending on model). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet Hole

Figure 34 - Pilot Inlet Air Hole

Pilot Air Inlet Hole

Figure 35 - Pilot Inlet Air Hole

  • LOG Set
  • If you remove one-piece log set for cleaning, refer to page 16, for placement instructions.
  • Replace log set if broken or chipped (dimesized or larger).

CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to re- move dust.

Primary Air Inlet Holes

Figure 33 - Orifice Holder On Outlet

Wiring Diagram

Gas Control TPTH TH

TPTH TP

Show 11 more labels / short text on this page
Pilot Assembly · (Propane/LP Gas) · Pilot Assembly · (Natural Gas) · Orifice Holder · Burner Tube · Burner Tube · Blue · (Remote-Ready Models Only) · Red · White Thermopile
Page 22 of the FMI CDCFPRB user manual — OBSERVED PROBLEM
Page 22 · click to enlarge
Page 22

Troubleshooting

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/ pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Replace ignitor cable 4. Replace piezo ignitor 5. Replace pilot assembly
3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode positioned wrong 6. Ignitor electrode broken
6. Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve
2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly 7. Replace gas regulator
5. Depleted gas supply (propane/LP only) 6. ODS/pilot is clogged
7. Gas regulator setting is not correct
Page 23 of the FMI CDCFPRB user manual — OBSERVED PROBLEM
Page 23 · click to enlarge
Page 23

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation 4. Fully open equipment shutoff valve 5. A) Contact local natural or propane/LP gas company B) Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly
3. Safety interlock system has been triggered
4. Equipment shutoff valve not fully open 5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 6. Thermocouple connection loose at control valve 7. Thermocouple damaged 8. Control valve damaged
6. Hand tighten until snug, then tighten 1/4 turn more 7. Replace pilot assembly 8. Replace control valve

Burner does not light after ODS/pilot is lit

1. Inlet gas pressure is too low 2. Burner orifice is clogged
1. Contact local natural or propane/LP gas company 2. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice 3. Reconnect leads (see Wiring Diagram , page 21)
3. Thermopile leads disconnected or improperly connected (Remote-Ready Models Only) 4. Burners will not come on in remote position (RemoteReady Models Only)
4. Replace battery in transmitter and receiver

Delayed ignition of burner

1. Manifold pressure is too low 2. Burner orifice is clogged
1. Contact local natural or propane/LP gas company 2. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice

Burner backfiring during com- bustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice 2. Replace damaged burner 3. Replace gas regulator 4. Contact local natural or propane/LP gas company
2. Damaged burner 3. Gas regulator defective 4. Inlet gas pressure is too low
Page 24 of the FMI CDCFPRB user manual — OBSERVED PROBLEM
Page 24 · click to enlarge
Page 24

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Slight smoke or odor during initial operation

1. Residues from manufacturing processes and log curing 2. Not enough air
1. Problem will stop after a few hours of operation
2. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 20) 3. Replace gas regulator
3. Gas regulator defective

Fireplace produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural gas company 3. Observe minimum installation clearances (see page 10) 4. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice
3. Air passageways on fireplace blocked 4. Dirty or partially clogged burner orifice

White powder residue forming within burner box or on adja- cent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Turn fireplace off when using furniture polish, wax, carpet cleaners or similar products

Moisture/condensation no- ticed on windows

1. Not enough combustion/ ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 6)

Remote does not function

1. Battery is not installed. Battery power is low
1. Replace 9-volt batteries in receiver and remote control

Fireplace produces a clicking/ ticking noise just after burners are lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is normal with most fireplaces. If noise is excessive, contact qualified service person
Page 25 of the FMI CDCFPRB user manual — OBSERVED PROBLEM
Page 25 · click to enlarge
Page 25

TROUBLESHOOTING

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwant- ed odors

1. Fireplace burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Low fuel supply (propane/ LP only) 3. Gas leak. See Warning statement at top of page
1. Open window to ventilate room. Stop using odor causing products while fireplace is running
2. Refill supply tank (propane/ LP only) 3. Locate and correct all leaks (see Checking Gas Connections , page 14)

Fireplace shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural or propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 20)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page
1. Locate and correct all leaks (see Checking Gas Connections , page 14) 2. Replace control valve
2. Control valve defective

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 14)
Page 26 of the FMI CDCFPRB user manual — Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1, CDCFNRB-1
Page 26 · click to enlarge
Page 26

Parts

Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1, CDCFNRB-1

FMI CDCFPRB — Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1, CDCFNRB-1 diagram (page 26)
Fig. 27 · Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1, CDCFNRB-…
Page 27 of the FMI CDCFPRB user manual — CDCF
Page 27 · click to enlarge
Page 27

Parts

Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1, CDCFNRB-1 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

CDCF

  • KEY NO. PART NO. DESCRIPTION QTY. 1 ** Outer Casing Top
  • 1 2 ** Baffle
  • 1 3 ** Outer Casing
  • 1 4 104281-02 Firebox Hood
  • 1 5 ** Firebox Top
  • 1 6 ** Firebox Wrapper
  • 1 7 ** Outer Base
  • 1 8 102635-02 Front Left and Right Sides
  • 2 9 103209-05 Extruded Louver
  • 2 10 098304-01 Screw, PPH AB 10-16 x 0.38
  • 12 11 M10908-2 Screw, SLTD HWH TPG 6-32 x 0.38
  • 4 12 104313-01 Right Pin Hinge
  • 1 13 104313-02 Left Pin Hinge
  • 1 14 099230-02 Screw, HWH SHLDR AB 10 x 0.63
  • 14 15 111038-02 Remote/Blower Bracket
  • 1 16 M11084-26 Screw, HWH AB 10-16 x 0.38
  • 35 17 111633-01 Box Cover
  • 1 18 111200-01 Support Bracket
  • 1 19 103295-05 Screen Frame 1

** Not a field replacement part

Page 28 of the FMI CDCFPRB user manual — REMOTE-READY MODELS CDCFNRB, CDCFPRB, CDCFNRB-1, CDCFPRB-1
Page 28 · click to enlarge
Page 28

Parts

REMOTE-READY MODELS CDCFNRB, CDCFPRB, CDCFNRB-1, CDCFPRB-1

FMI CDCFPRB — REMOTE-READY MODELS CDCFNRB, CDCFPRB, CDCFNRB-1, CDCFPRB-1 diagram (page 28)
Fig. 28
Page 29 of the FMI CDCFPRB user manual — CDCFPRB-1
Page 29 · click to enlarge
Page 29

Parts

REMOTE-READY MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

CDCFPRB-1

CDCFNRB-1

CDCFPRB

CDCFNRB

  • KEY NO. PART NO. DESCRIPTION QTY. 1 111069-01 Dual Burner
  • 1 2 099056-29 Orifice
  • 1 099056-34 Orifice
  • 1 3 103342-04 Outlet Tube
  • 1 111195-07 Outlet Tube
  • 1 4 111124-01 Burner Retainer Spring
  • 1 5 097809-02 Male Fitting
  • 1 6 103778-01 ODS Pilot
  • 1 103779-01 ODS Pilot
  • 1 7 099387-09 Pilot Tube
  • 1 099387-12 Pilot Tube
  • 1 8 098249-01 ODS Nut
  • 2 9 M11084-26 Screw, HWH AB 10-16 x 0.38
  • 10 10 ** Chamber Floor
  • 1 11 110793-01 Piezo Bracket
  • 1 12 102445-01 Piezo Ignitor with Palnut Fastener
  • 1 13 101628-01 Flexible Connector
  • 1 14 098271-10 Ignitor Cable
  • 1 15 M12461-26 Screw, MX SLT WSR 10-32 x 3/8
  • 4 16 111173-01 Remote Valve Bracket
  • 2 17 103781-02 Gas Valve
  • 1 103781-01 Gas Valve
  • 1 18 101480-12 ASM High Temp Wire 1 19 097809-02 Male Fitting
  • 1 20 113342-01 Log Set
  • 1 21 099918-02 Pilot Regulator
  • 1 22 099387-14 Pilot Tube
  • 1 PARTS AVAILABLE — NOT SHOWN 901056-01 Brass Flare Adapter Fitting
  • 1 103470-01 Hardware Pack
  • 1 100563-01 Warning Plate
  • 1 103877-01 Lighting Instruction Plate
  • 1 113140-02 Perimeter Trim Kit
  • 1 GWMT1 Wall Switch Kit
  • 1 MLCR-M Remote Control Kit

** Not a field replacement part

Page 30 of the FMI CDCFPRB user manual — Technical Service
Page 30 · click to enlarge
Page 30
  • Specifications CDCFPRB, CDCFPRB-1
  • Rating (Variable): 17,000/26,000 Btu/Hr
  • Type Gas: Propane/LP
  • Ignition: Piezo
  • Manifold Pressure: 8" W.C.
  • Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
  • CDCFNRB, CDCFNRB-1
  • Rating (Variable): 17,000/26,000 Btu/Hr
  • Type Gas: Natural
  • Ignition: Piezo
  • Manifold Pressure: 3.5" W.C.
  • Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.

* For purpose of input adjustment

Replacement Parts If this product is missing a part or has a broken component, please do not return it to the store. Call FMI PRODUCTS, LLC at 1-866-328-4537 to answer questions and replace parts under warranty. Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

  • When calling, have ready:
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • purchase date
  • Service Hints When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • fireplace will not produce specified heat
  • for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

Technical Service

You may have further questions about installa- tion, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready.

You can also visit our web site at www.fmiproducts.com.

Page 31 of the FMI CDCFPRB user manual — ON
Page 31 · click to enlarge
Page 31

Accessories

WALL-MOUNT ON/OFF SWITCH GWMS2 For all models. Allows the fireplace to be turned on and off with a wall switch.

Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the ad- dress listed on the back page of this manual.

WALL-MOUNT THERMOSTAT SWITCH - GWMT1 For all models. The desired comfort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pilot to the heat setting selected.

Perimeter Trim Kit GAP6094 - Platinum For all models. Optional three-sided perim- eter trim kit for custom and recessed instal- lations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening. Black trim included with the fireplace.

Brick Liners - Series 3 HFL200 - Aged Almond, Straight Brick Pattern HFL201 - Aged Red, Straight Brick Pattern For all models. Allows firebox interior to be aesthetically enhanced.

F

ON

OFF

MODE

SET

THERMOSTAT-CONTROLLED BLOWER KIT - GA3450TA For all models. Provides better heat distribu- tion. Makes fireplace more efficient. Automati- cally turns off and on as needed.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - CTRC For all Remote-Ready Models. Allows the fireplace to be operated in a manually or thermostatically controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair.

CORNER MANTEL WITH Full HEARTH BASE C26GO - Oak Finished, Georgian Design C26TO - Medium Oak Finished, Traditional Design C26TU - Unfinished, Traditional Design For all models. Space saving mantel and hearth base corner design features clean, classic lines. Complete assembly instructions included.

ON

OFF

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - CMRC For all Remote-Ready Models. Allows the fireplace to be turned on and off by using a hand-held remote control.

CABINET MANTEL and full hearth base W26GO - Medium Oak Finished, Georgian Design W26TO - Medium Oak Finished, Traditional Design W26TU - Unfinished, Traditional Design For all models. Complete assembly instruc- tions included.

Gas Appliance Installation Kit - CIKA For all models.

Page 32 of the FMI CDCFPRB user manual — FMI PRODUCTS, LLC LIMITED WARRANTIES
Page 32 · click to enlarge
Page 32

Warranty

KEEP THIS WARRANTY

Model (located on product or identification tag)

Serial No. (located on product or identification tag)

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.

Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).

This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war- ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.

FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For information about this warranty contact:

2701 S. Harbor Blvd. Santa Ana, CA 92704 www.fmiproducts.com

124979-01 Rev. C 06/10

Date Purchased 1-866-328-4537

Ask about the FMI CDCFPRB

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.