Residential and Outdoor Wood burning Fireplace

OWNER’S OPERATION AND INSTALLATION MANUAL

FMI (V)S36 — OWNER’S OPERATION AND INSTALLATION MANUAL diagram (page 1)
Fig. 1

PFS ®

US C

ICC-ES #ESR-2542

SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re placement parts or accessory items when needed. Keep it with your other important papers.

This fireplace is approved for use as a wood burning fire place or for use with a vented gas log approved to ANS Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A FMI PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Accessories, page 16).

This wood burning fireplace complies with UL127- CAN/ULS-S610-M87 standard as a FACTORY BUILT APPLIANCE.

FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to deter mine the need to obtain a permit.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Models (V)S36 Series

Page 2 of the FMI (V)S36 user manual — Safety
Page 2 · click to enlarge
Page 2

Table of Contents Safety 2 Specifications 3 Fireplace Installation 4 Venting Installation 6 Optional Gas Line Installation 11

Operation and Maintenance Guidelines 12 Parts 14 Technical Service 17 Accessories 17

Safety

  • FOR YOUR SAFETY
  • Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.
  • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
  • Do not place clothing or other flammable materials on or near the appliance.
  • Never leave children unat tended when a fire is burning in the fireplace.
  • Before beginning installation of this fireplace, read these instructions through completely.
  • This FMI PRODUCTS, LLC fireplace and its components are safe when installed according to this installation manual. Unless you use FMI PRODUCTS, LLC components, which have been designed and tested for the fireplace system, you may cause a fire hazard.
  • The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions. a. Modification of the fireplace, com

ponents, doors, air inlet system and damper control. b. Use of any component part not manufac

tured or approved by FMI PRODUCTS, LLC in combination with a FMI PROD UCTS, LLC fireplace system. Proper installation is the most important step in ensuring safe and continuous operation of fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces.

This fireplace is not intended to be used as a substitute for a furnace to heat an entire home. Use for supplemental heat only.

Page 3 of the FMI (V)S36 user manual — GAS LINE KNOCK OUTS
Page 3 · click to enlarge
Page 3

Specifications

FMI (V)S36 — Specifications diagram (page 3)
Fig. 2 · Specifications

GAS LINE KNOCK OUTS

Page 4 of the FMI (V)S36 user manual — Fireplace Installation
Page 4 · click to enlarge
Page 4

Fireplace Installation

selecting location To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clear ances (see Figures 1 and 2). 2. Consider a location where the fireplace will not be affected by drafts, air condition ing ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. 4. An outside air kit is available with this fireplace (see Optional Outside Air Kit on page 6).

Framing 1. Frame opening for fireplace using the dimensions shown in Figures 1 and 2. 2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, the fireplace must be installed upon a metal or wood panel extending the full width and depth of fireplace. 3. Set fireplace directly in front of this open ing and slide unit back until nailing flanges touch side framing. 4. Check the level of the fireplace and shim with sheet metal if necessary. 5. Before securing fireplace to prepared framing, the ember protector (provided) must be placed between the hearth ex tension (not supplied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z- type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should ex tend under fireplace a minimum of 1 1/2". The ember protector should be made of galvanized sheet metal (28 gauge mini mum) to prevent corrosion. 6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace.

Minimum clearance to combustibles Back and sides of fireplace 3/4" minimum* Floor** 0" minimum Perpendicular wall to opening 12" minimum Top spacers 0" minimum Mantel clearances see Mantels, page 5 Chimney outer pipe surface 1" minimum * Not required at nailing flanges ** See step 2 of Framing

Minimum/Maximum Chimney Height for Residential Installation The minimum height of the chimney, mea sured from the base of the fireplace to the flue gas outlet of the termination, is 14.5 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 6 feet. For systems with two elbow sets, the minimum height is 22 feet. The maximum height of any system is 50 feet. This measurement includes the fireplace, chimney sections and the height of the termination assembly at the level of the flue gas outlet (see Figure 18, page 11).

41.375"

41.250" Figure 1 - Framing Dimensions

21.875"

Minimum/Maximum Chimney Height for Outdoor Installation The minimum height of the chimney, mea sured from the base of the fireplace to the flue gas outlet of the termination, is 7 1/2 feet (minimum of 4 feet of chimney pipe sections required for outdoor installation).

17.253"

MAINTAIN 3/4" CLEARANCE AT SIDES AND BACK OF FIREPLACE

24.399"

52.183"

3/4" CLEARANCE NOT REQUIRED AT NAILING FLANGES

73.798"

Figure 2 - Corner Installation

Page 5 of the FMI (V)S36 user manual — Fireplace Installation
Page 5 · click to enlarge
Page 5

Fireplace Installation

Drain Pan (DP36) For outdoor installations, the fireplace enclo sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the fireplace within the fireplace enclosure (see Accessories on page 16).

Mantels A mantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from the front face must not be placed within 12" of the fireplace opening. Combustible materials above 12" and pro jecting more than 11/2" from the fireplace must not be placed less than 15" from the top opening of the fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material also may come up to the side edge of the black metal face of the fireplace just as long as the projection from the front face fall within the limit shown in Figure 4.

Hearth Extension A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncom bustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply: 0.25 x 1.0" = 0.30" thickness required 0.84 Thermal conductivity "K" of materials can be obtained from the manufacturer or supplier of the noncombustible material. If the hearth ex tension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material (see Figure 3).

12 1/" Ref. 4 6" Ref. 33° 3" Nom. 12" Min.11/" Max. 2 9" Min.
FMI (V)S36 — Fireplace Installation diagram (page 5)
Fig. 3 · Fireplace Installation
FMI (V)S36 — Fireplace Installation diagram (page 5)
Fig. 4 · Fireplace Installation

Figure 4 - Mantel Clearances to

Figure 3 - Hearth Extension

Combustible Material

Page 6 of the FMI (V)S36 user manual — Fireplace Installation
Page 6 · click to enlarge
Page 6

Optional Outside air Kit (Model ak4/ak4f) The installation of an outside air kit should be performed during the rough framing of the fire place due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 22 on page 13 for instruction of operating air kit.

LINEAL GAIN PART NO.DESCRIPTIONGAIN 36"Fireplace40" 12-8DM 12-8HTPipe Section10 5/ 8" 18-8DM 18-8HTPipe Section16 5/ 8" 24-8DM 24-8HTPipe Section23 5/ 8" 36-8DM 36-8HTPipe Section34 5/ 8" 48-8DM 48-8HTPipe Section46 5/ 8" RT-8DMRound Termination6 7/ 8"* RTL-8DMRound Termination7 3/ 4"* RTT-8DMRound Termination with Slip Section6 7/ 8" to 23 1/"* 8 RTTL-8DMRound Termination with Slip Section8 1/ 2" to 21 1/"* 2 ET-8DMSquare Chase-Top12"* ETO-8DMSquare Chase-Top with Mesh12"* ETL-8DMSquare Chase-Top with Slip Section7" to 15"* ETLO-8DMSquare Chase-Top with Mesh & Slip Section12" to 25 1/"* 2

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet Location Must Allow For Bushes or Snow

* The lineal gain for the terminations is mea sured to the flue gas outlet height.

Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)

Vent Hood Required for Wall Installation

12 3/8" Galvanized Outer Pipe

Figure 5 - Outside Air Kit

Hemmed End 8" Stainless Inner Pipe

Chimney Pipe The FMI PRODUCTS, LLC chimney system consists of 12", 18", 24", 36" and 48" snap- lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fit ting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

Figure 6 - Lineal Gain

Assembly and installation of double wall chimney system Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed.

Air Inlet Eyebrow

Page 7 of the FMI (V)S36 user manual — Fireplace Installation
Page 7 · click to enlarge
Page 7

When connecting chimney directly to the fireplace, the inner flue pipe section must be installed first with the lanced side up. The outer pipe section can then be installed over the flue pipe section with the hemmed end up. Press down on each pipe section until the lances securely engage the hem on the fireplace starter. The wire will assure the proper spacing between the inner and outer pipe sections. Continue to assemble chimney sections as outlined, making sure that both the inner and outer pipe sections are locked together. When installing double wall snap-lock chimney together, it is important to assure the joint between the chim ney sections is locked. Check by pulling chimney upward after locking. The chimney will not come apart if properly locked. It is not necessary to add screws to keep the chimney together (exception - see Figure 9, page 8).

OFFSETRISECHIMNEY LENGTH AB48"36"24"18"12" 4 3/" 816 3/" 8ELBOW SET ONLY 9 3/" 425 1/" 21 12 3/" 430 3/" 41 15"34 3/" 41 18"40"11 21 1/" 446 1/" 41 23 3/" 449 1/" 411 27 3/" 456 3/" 41 30"60 3/" 411 33"66"11 36"71"11 38 1/" 475"2 41 1/" 480 1/" 4111 45"86 3/" 42 46 3/" 489 1/" 2111 51"97"11 53 1/" 4101"21 56 1/" 4106 1/" 42 59 1/" 4111 1/" 2111 61 3/" 4115 1/" 221 64 3/" 4120 3/" 421 68 1/" 4127"12 70"130"211 74 1/" 4137 1/" 2121 76 3/" 4141 1/" 2121 79 3/" 4146 3/" 44

Using ELBOW offsets (30E-8DM) 1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). 2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 8, details A and B on page 8). 3. Maximum length of pipe between supports (return elbow or 12S-8DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 7). 4. All pipe connections between offset and return must be secured with two screws on outer pipe only (see Figure 9, page 8). Do not penetrate inner stainless.

FMI (V)S36 — Fireplace Installation diagram (page 7)
Fig. 5 · Fireplace Installation

Figure 7 - Typical Offset Terminations

Return Elbow

Page 8 of the FMI (V)S36 user manual — A
Page 8 · click to enlarge
Page 8

2" Min.

Screws or Staples (Min. of 8)

Detail B Angle Firestop

Figure 10 - Firestop Spacer with Living

Screws or Staples (Min. of 8)

Detail A Return Elbow

Existing Ceiling Frame Figure 8 - Ceiling Support Pipe

12S-8DM

Figure 11 - Firestop Spacer with Attic

B

Penetrating roof To maintain a 1" clearance to the pipe on a roof with a pitch, a rectangular opening must be cut. 1. Determine center point through which pipe will penetrate roof. 2. Determine center point of roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters. 3. Use roof opening chart (Figure 12, page 9) to determine the correct opening length and flashing required. 4. Remove the shingles around opening measured. Cut out this section. 5. Add next sections of pipe until end pen etrates roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.

A

Figure 9 - Elbow Offset

Firestop Spacers (3600FS-8DM-1) Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 10. They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11.

Show 11 more labels / short text on this page
See Detail A · Existing Ceiling Frame · Firestop Spacer · Straps · Straps · See Detail B · Space Above Ceiling · Straps Straps · Firestop Spacer · Space Above Ceiling · Screws
Page 9 of the FMI (V)S36 user manual — RTL-8D
Page 9 · click to enlarge
Page 9

Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 14). Use SC1 for all round terminations and SC2 for all terminations with slip sections. Apply waterproof caulk around the perimeter of the collar to provide a proper seal.

14 3/8" (36.5 cm) 1" 30" (2.5 (76.2 cm) cm) 1" (2.5 cm) 1" (2.5 cm) Opening "A" PitchSlope Opening "A" Max.Used Flashing Model No. Flat0°15"V6F-8DM 0-6/1226.6° 16 1/8"V6F-8DM 6/1212/1245.0° 20 3/8"V12F-8DM
FMI (V)S36 — RTL-8D diagram (page 9)
Fig. 6
FMI (V)S36 — RTL-8D diagram (page 9)
Fig. 7

Figure 14 - Storm Collar

Terminations/Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination. The termination approved for this fireplace are the RT-8DM and RTL-8DM that can be used for flashing or chase and ET-8DM, ETO-8DM, ETL-8DM and ETLO- 8DM for chase style termination only. Figure 15 shows an RTL-8DM round top termination.

Figure 12 - Roof Opening Measurements

Flashing installation (v6f-8dm or v12f-8dm) Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nail ing through shingles (see Figure 13). DO NOT NAIL THROUGH FLASHING CONE.

FMI (V)S36 — RTL-8D diagram (page 9)
Fig. 8

Installing Flashing on a Metal Roof When installing flashing on a metal roof, it is required that putty tape be used between the flashing and roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through screw holes. A roof coating must also be applied around perimeter of flashing to provide a proper seal.

Attach Bracket Tabs to Outer Pipe (3 Places) Secure with Screws

RTL-8D

FMI (V)S36 — RTL-8D diagram (page 9)
Fig. 9
FMI (V)S36 — RTL-8D diagram (page 9)
Fig. 10

Figure 13 - Flashing Installation

Figure 15 - Termination

Minimum Measurements · Chimney Pipe

Page 10 of the FMI (V)S36 user manual — RTL-8D
Page 10 · click to enlarge
Page 10

Terminations with 16" slip pipe sections are available. The RTT-8DM and RTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve the correct chimney height. Note: In the rare instance there is a problem with the side driven rain or wind or the chim ney is not drafting properly, an ADS-8DM (Anti-Draft Shield) can be used with round terminations.

10 foot rule All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the high est point of the roof that is within a horizontal distance of 10 feet (see Figure 17).

FMI (V)S36 — RTL-8D diagram (page 10)
Fig. 11

Chase installations Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24", center to center and stacked at a vertical height dif ference of 18" (see Figure 16). Note: If a decorative shroud is to be installed, contact the manufacturer for specifications.

Figure 17 - 10 Foot Rule

finishing fireplace Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.

FMI (V)S36 — RTL-8D diagram (page 10)
Fig. 12

Figure 16 - Multiple Chase Installation

Page 11 of the FMI (V)S36 user manual — Optional Gas Line Installation
Page 11 · click to enlarge
Page 11

EFFECTIVE HEIGHT OF TERMINATION CAP

EFFECTIVE HEIGHT OF TERMINATION CAP

MIN. HEIGHT OF 22 FT. (WITH 2 ELBOW SETS) MAX. HEIGHT OF 50 FT.

MAX. HEIGHT 50 FT. (ANY SYSTEM)

EFFECTIVE HEIGHT OF TERMINATION CAP

EFFECTIVE HEIGHT OF TERMINATION CAP

14.5 FT. MINIMUM

14.5 FT.

MINIMUM HEIGHT

UP TO 6FT. MAX. HEIGHT

UP TO 6FT. MAX.

30E-8DM

30E-8DM

Figure 18 - Typical Residential Installations

Optional Gas Line Installation

Gas line hook up should be done by your supplier or a qualified service person. Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropri ate fittings. 1. Remove knockout indentation on refrac tory or firebrick wall located above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 19). 2. Remove gas line cover plate located on either side of fireplace and pull out insu lation from gas line conduit sleeve. Save insulation for reuse. Replace screws. 3. Run a 1/2" black iron gas line into the fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection

(see Figure 20, page 12). Note: Secure incoming gas line to wood framing to provide rigidity for threaded end. 4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap- off gas line if desired.

Side Firebrick Finished Side

Figure 19 - Gas Line Knockout

Show 6 more labels / short text on this page
Outside of Fireplace · Gas Line Conduit · 1/2" Dowel · Insulation · Gas Conduit Cover · Refractory Knockout Plug
Page 12 of the FMI (V)S36 user manual — Operation and Maintenance Guidelines
Page 12 · click to enlarge
Page 12

Optional Gas Line Installation

CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALI FIED SERVICE PERSON.

If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60, Z21.84 or RG 2-72 and shall also be installed in accor dance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.

Side Firebrick Finished Side

Incoming 1/2" Black Iron Pipe

Seal Opening with Refractory Cement

Provide Enough Threaded End for Fitting Connection Figure 20 - Gas Line Installation

Operation and Maintenance Guidelines

Glass Doors Glass doors are optional with the fireplace. When the fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 21). A fireplace equipped with glass doors oper ates mush differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Exces sive heat within the fireplace can result if too large a fire is built or if the combustion air gate is not completely open.

Figure 21 - Glass Doors

Show 7 more labels / short text on this page
Outside of Fireplace · Gas Line Conduit · Repack Insulation · Doors Fully Closed · Fireplace Front · Doors Fully Opened · Fireplace Front
Page 13 of the FMI (V)S36 user manual — OPEN CLOSE
Page 13 · click to enlarge
Page 13

Operation and Maintenance Guidelines

The following tips should be followed to as sure that both the fireplace and the glass door retain their beauty and function properly. Both the flue damper and the glass doors must be fully opened before starting the fire. This will provide sufficient combustion air and maintain safe temperatures in the firebox. IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass.

outside air and damper handle operation The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle into the left of the keyway slot will free the damper blade to automatically open. Pushing the handle in to the right will lock the damper blade closed (see Figure 22). The outside air kit handle is located at the left hand side of the fireplace (see Figure 22). Pulling the handle out will free the outside air door to open. Pushing the handle in will lock the door closed.

For further operating guidelines, instructions and warranty information, please refer to your homeowner's guide or contact your authorized dealer.

Cleaning Glass Clean the glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean the glass. Do not clean the glass with any cool water is the glass is still hot from the fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or vent- free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 dated August, 1993. If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace.

OPEN CLOSE

Outside Air Kit Handle

Figure 22 - Damper and Air Kit Handle

Damper Handle · Keyway Slot · Handle Retainer

Page 14 of the FMI (V)S36 user manual — Parts
Page 14 · click to enlarge
Page 14

Parts

Wood burning Fireplace MODELS S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, vs36r AND vs36rh

FMI (V)S36 — Parts diagram (page 14)
Fig. 13 · Parts
Page 15 of the FMI (V)S36 user manual — PARTS
Page 15 · click to enlarge
Page 15

PARTS

Wood burning Fireplace MODELS S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, vs36r and vs36rh This list contains replaceable parts used in your fireplace.

KEY NO. PART NO. DESCRIPTION QTY. 1 106638-01 Insulation Pan 1 2 ** Fireplace Top 1 3 106641-01 Fireplace Surround 1 4 106642-01 Air Rod Retainer 1 5 106643-01 Damper Rod Retainer 1 6 ** Firebox Bottom 1 7 ** Firebox Surround 1 8 ** Air Separator 1 9 See Below Left Refractory 1 10 See Below Right Refractory 1 11 See Below Rear Refractory 1 12 See Below Bottom Rear Refractory 1 13 See Below Bottom Front Refractory 1 14 106683-01 Firebox Support Leg 4 15 106687-01 Damper Can Collar 1 16 106691-01 Screen Rod 2 17 ** Firebox Top Assembly 1 18 106703-01 Air Kit Door Assembly 1 19 ** Face Weldment 1 20 110892-01 Air Deflector 1 21 111327-01 Fireplace Top Insulation 1 22 107775-01 Access Panel 1 23 107854-01 Right Refractory Bracket 1 24 107854-02 Left Refractory Bracket 1 25 111028-01 Grate 1 26 11418 Push-On Nut 2 27 110890-01 Stainless Screen 2 28 16405 Collar Insulation 1 29 20023 Chimney Starter Collar 1 30 20027 Refractory Retainer 2 31 106539-02 Grate Retainer 2 32 111073-01 Door Stop 1 33 111204-01 Pivot Clip 2 34 20090 Spring Clip 2 35 20280 Top Spacer 4 36 21171 Conduit Plate Cover 4 37 21379 Gas Conduit 2 38 21380 Gas Conduit 2 Parts Available Not Shown 106625-01 Home Owner’s Guide 1 20093 Ember Protector 2 ** Not a field replaceable part

Page 16 of the FMI (V)S36 user manual — S36H
Page 16 · click to enlarge
Page 16

PARTS

Wood burning Fireplace MODELS S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, vs36r and vs36rh

S36, S36-LS

S36RH

VS36H

VS36R

VS36RH

  • KEY NO. PART NO. DESCRIPTION QTY. 9 106658-03 Left Refractory, Textured White Brick
  • 1 108164-03 Left Refractory, Textured White Herringbone
  • 1 106658-02 Left Refractory, Textured Red Brick
  • 1 108164-02 Left Refractory, Textured Red Herringbone
  • 1 106658-01 Left Refractory, Smooth White Brick
  • 1 108164-01 Left Refractory, Smooth White Herringbone
  • 1 10 106659-03 Right Refractory, Textured White Brick
  • 1 108165-03 Right Refractory, Textured White Herringbone
  • 1 106659-02 Right Refractory, Textured Red Brick
  • 1 108165-02 Right Refractory, Textured Red Herringbone
  • 1 106659-01 Right Refractory, Smooth White Brick
  • 1 108165-01 Right Refractory, Smooth White Herringbone
  • 1 11 106660-03 Rear Refractory, Textured White Brick
  • 1 108166-03 Rear Refractory, Textured White Herringbone
  • 1 106660-02 Rear Refractory, Textured Red Brick
  • 1 108166-02 Rear Refractory, Textured Red Herringbone
  • 1 106660-01 Rear Refractory, Smooth White Brick
  • 1 108166-01 Rear Refractory, Smooth White Herringbone
  • 1 12 110899-01 Bottom Rear Refractory, White Brick
  • 1 110899-02 Bottom Rear Refractory, Red Brick
  • 1 13 110900-01 Bottom Front Refractory, White Brick
  • 1 110900-02 Bottom Front Refractory, Red Brick

S36H

S36R

VS36

Show 6 more labels / short text on this page
Right Side · Rear · Bottom · Front Bottom · Left Side · Refractory Brick
Page 17 of the FMI (V)S36 user manual — DRAIN PAN DP36
Page 17 · click to enlarge
Page 17

Technical Service You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.

Accessories

Double Wall Pipe 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT

Bi-Fold Glass Door BDO36 - Black BDO36B - Brushed Brass BDO36P - Platinum

ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM

30° Offset and return 30E-8DM

ANTI-DRAFT SHIELD (Round Top Termination Only) ADS-8DM

Firestop Spacer 3600FS-8DM-1

Hood STAINLESS STEEL- HS36 Required when installing a vent-free gas log in this fireplace.

DRAIN PAN DP36

Page 18 of the FMI (V)S36 user manual — Round Top Terminations RT-8DM, RTL-8DM
Page 18 · click to enlarge
Page 18

Accessories

Round Top Terminations RT-8DM, RTL-8DM

RounD Top Terminations with Slip Section RTT-8DM, RTTL-8DM

Outside Air Kit for Side Wall Installation - AK4

RounD Top Terminations with LOUVERS RTL-8DM

Outside Air Kit for Floor Installation - AK4F

Storm Collar SC1-1 For RT-8DM and RTL-8DM SC2-1 For RTT-8DM and RTTL-8DM

Square Chase-Top Termination ET-8DM, ETO-8DM

Econo-Top Termination with Slip Section ETL-8DM, ETLO-8DM

Page 19 of the FMI (V)S36 user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 19 · click to enlarge
Page 19

NOTES

Page 20 of the FMI (V)S36 user manual — NOTES
Page 20 · click to enlarge
Page 20

2701 S. Harbor Blvd. Santa Ana, CA 92704

111026-01 Rev. J 02/10

1-866-328-4537 www.fmiproducts.com

Ask about the FMI (V)S36

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FMI (V)S36

Be the first to ask — other owners or our team will answer.