MODELS (V)dvf36ns, (V)dvf36ps, (V)dvf36nh, (V)dvf36ph,
dvf-36ns-ha, dvf36nh-ha, (V)dvf42ns, (V)dvf42ps, (V)
dvf42nh, (V)dvf42ph, dvf-42ns-ha, and dvf42nh-ha
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com



Lower Door/ Control Cover
Figure 1 - Direct Vent Fireplace

Flush with a wall
Through exterior wall enclosed in a chase
Figure 2 - Common Fireplace Locations
29" (36") 34 3/4" (42") 21" (36") 25" (42")
11 7/8" (36") 13 5/8" (42")
41 1/4" (36") 48 1/4" (42")
Figure 3 - Fireplace Top Dimensions
Corner installation

Clearances Minimum clearances to combustibles for the fireplace are as follows: *Back and sides 1" Perpendicular walls 6" Floor 0" Ceiling to louver opening 42" Front 36" Top of Standoffs 0" Vent (See venting instructions for specific venting clearances.) Combustible material with a maximum thick ness of 5/8" may be flush with the top front of fireplace. * For back and sides of fireplace, do not pack with insulation or other materials. 1" clearance not required at nailing flanges.

43 1/4" (36") 47 1/4" (42")
41 1/2" (36") 48 1/2" (42")
Figure 4 - Framing Clearances with
Outside Air Flex Duct


51 3/8" (36") 61 3/4" (42")
36 3/8" (36") 43 3/8" (42")
42" (36"), 49" (42") 15 3/4" (36") 19" (42")
Figure 5 - Framing Clearances for Corner

Framing and finishing Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met. If you are using a separate combustible man tel piece, refer to Figure 6 for proper instal lation height. You can install noncombustible mantels at any height above the fireplace. Note: Noncombustible mantels may discolor!
Installation · Mantels


TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.5 cm) minimum] B = clearance to window or door that may be opened [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] C = clearance to permanently closed window [minimum 12" (30.5 cm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24" (61 cm) from the center-line of the terminal [18" (45.7 cm) minimum] E = clearance to unventilated soffit [12" (30.5 cm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within 36" (91.4 cm) horizontally from the center line of the regulator
I = clearance to service regulator vent outlet [*72" (182.9 cm) minimum] J = clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] K = clearance to a mechanical air supply inlet [*In Canada, 6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within 10 ft. (3 m) horizontally] L = † clearance above paved side-walk or a paved driveway located on public property [*84" (213.3 cm) minimum] M = clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡] N = clearance above a roof shall extend a minimum of 24" (61 cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18" (45.7 cm) † vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Outside Corner Recessed Location

C = Maximum depth of 48" (121.9 cm) for recessed location D = Minimum width for back wall of recessed location - Combustible - 38" (965 mm) Noncombustible - 24" (61 cm) E = Clearance from corner in recessed location- Combustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm)
Combustible & Noncombustible H = 24" (61 cm) J = 20" (50.8 cm)
Figure 7 - Minimum Clearances for Termination Cap
Inside Corner

Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall ex haust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizon tal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery backup is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired car bon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than 1/2" in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".


etrated is constructed of noncombustible material, such as masonry block or con crete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9).
Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Hori zontal installations using round termination require exterior portion of wall firestop. 1. Set fireplace in its desired location and de termine the route your horizontal venting will take. Do not secure fireplace until all venting has been installed. Some instal lations require sliding fireplace in and out of position to make final venting connec tions. Figures 14 and 15 on page 12 show different configurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust location of fireplace. 2. Direct vent pipe sections and components are designed with special twist-lock con nections. Twist-Lock Procedure: Female ends of pipes have locking lugs (indentations). These lugs will slide straight into match ing slots on male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one- quarter turn until sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be sup ported every three feet. Use wall straps for this purpose. 3. Assemble desired combination of pipe and elbows to fireplace flue collar. If there are long portions of venting run, pre-as sembled pipe sections may be installed as subassemblies for convenience. 4. Carefully determine location where vent pipe assembly will penetrate outside wall. Center of hole should line up with center line of horizontal vent pipe. Mark wall for an 11 1/2" x 11 1/2" square hole. Cut and frame square hole in exterior wall where vent will be terminated. If wall being pen
Figure 8 - Vent Pipe Connections
Vent Opening Combustible Wall
11 1/2" Inside Framing
11 1/2"
11 1/2"
Vent Opening Noncombustible Wall
8 1/2"
Figure 9 - Vent Opening Requirements

Carefully move fireplace, with vent as sembly attached, toward wall and insert vent pipe into horizontal termination. Pipe overlap should be a minimum of 1 1/4" (see Figure 13, page 13). Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13, page 13, for horizontal termination details. Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fire place is level before securing. If fireplace is not level it will not work properly.
5. Noncombustible Exterior Wall: Position horizontal vent cap in center of the 8 1/2" round hole and attach to exterior wall with four wood screws provided. Before attaching vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around outside edges to make a seal between it and outside wall. Note: Four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings (see Figure 10). Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between vent cap and exterior wall. Siding standoff prevents excessive heat from damaging siding materials. Siding material must be cut to accommodate standoff. Bolt vent cap to standoff. Apply non-hardening mastic around outside edge of standoff. Position standoff/cap assembly in the center of 11 1/2" square hole and attach to exterior wall with provided wood screws (see Figure 11). Siding standoff must sit flush against exterior fascia material. 6. Connecting Vent Cap with Horizontal Vent Pipe: Slide wall firestop over vent pipe before connecting horizontal run to vent cap (see Figure 12).

Apply Mastic to All Four Sides

Figure 11 - Installing Siding Standoff

Vent Cap (Horizontal Termination)
Figure 10 - Installing Horizontal Vent Cap
Horizontal Vent Pipe Figure 12 - Connecting Vent Cap with

Minimum Pipe Overlap 11/4
1' Pipe Min On Horizontal Run
V + 90· Elbow
1 ft. Min Before Elbow
Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall
Horizontal High Wind Square Termination
Apply Mastic to Outside Edge of Standoff Exterior Wall with Vinyl Siding
11 1/2" x 11 1/2" Framed Opening
64" Min. (42") 61" Min. (36")
Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed
Maximum 21" 1 ft. 3 ft. 33" 2 ft. 7 ft. 45" 3 ft. 11 ft. 57" 4 ft. 20 ft. V + H = 40 feet maximum
Horizontal Termination Configurations Figure 14 shows a configuration for venting with horizontal termination with a chart of critical minimum and maximum dimensions which MUST be met.
H = 20 feet maximum
Figure 14 - Horizontal Termination Using
Vertical Termination Installation Note: Vertical restrictor must be installed in all vertical installations. 1. Determine route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct venting system, con sider an offset (see Figure 15, page 14) to avoid cutting load bearing members. Note: Pay special attention to these instal lation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of venting system and any maximum horizontal offset limitations.

open vent pipes before cutting hole in roof.) The 11 1/2" x 11 1/2" hole must be measured on the horizontal; actual length may be larger depending on pitch of roof. There must be a 1" clearance from vent pipe to combustible materials. Frame opening as shown in Figure 9, page 11. 4. Connect a section of pipe and extend up through hole. Note: If an offset is needed to avoid obstructions, you must support vent pipe every 3 feet. Use wall straps for this pur pose (see Figure 15). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of flue gases. 5. Place flashing over pipe section(s) ex tending through roof. Secure base of flashing to roof and framing with roofing nails. Be sure roofing material overlaps top edge of flashing as shown in Figure 15. There must be a 1" clearance from vent pipe to combustible materials. 6. Continue to add pipe sections until height of vent cap meets the minimum building code requirements described in Figure 7 on page 8. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs and other similar factors may cause poor draft or down-drafting in high winds. Increasing vent height may solve this problem. 7. Twist-lock vent cap onto last section of vent pipe.
Figure 15 - Offset with Wall Strap and 45°
Flat Ceiling Installation 1. Cut a 11 1/2" square hole in ceiling using locating hole as a center point. Opening should be framed to 11 1/2" x 11 1/2" inside dimensions, as shown in Figure 8 on page 9 using framing lumber the same size as ceiling joists. If area above ceiling is an insulated ceiling or an attic, nail firestop from top side. This prevents loose insula tion from falling into required clearance space. If area above ceiling is a living space, install firestop below framed hole. Firestop should be installed with no less than three nails per side (see Figure 15). 2. Assemble desired lengths of pipe and elbows necessary to reach from fireplace flue up through firestop. Be sure all pipe and elbow connections are fully twist- locked (see Figure 8, page 11). 3. Cut a hole in the roof using locating hole as a center point. (Cover any exposed
Minimum Height Roof Pitch Feet Min. Flat to 6/12 1 6/12 to 7/12 1.25 Over 7/12 to 8/12 1.5 Over 8/12 to 9/12 2 Over 9/12 to 10/12 2.5 Over 10/12 to 11/12 3.25 Over 11/12 to 12/12 4 Over 12/12 to 14/12 5 Over 14/12 to 16/12 6 Over 16/12 to 18/12 7 Over 18/12 to 20/12 7.5 Over 20/12 to 21/12 8.0

High Altitude Installation Your FMI PRODUCTS, LLC direct vent fireplace has been tested and approved for elevations from 0-2000 feet. Fireplaces for high altitude (-HA Models) are for installations above 4,000 feet only. These fireplaces are equipped with parts specific for higher altitudes. When installing a non-high altitude fireplace at an elevation above 2000 feet, you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an elevation above 4500 feet, check with local authorities.
Vertical Termination Configurations Figure 17 shows the configurations for vertical termination.
If area above is an attic or insulated area,
install firestop above framed hole.
Parts list for venting kits and components FMI (5/8") Pipe & Vent Kits Number Description P58-6 6" Section Double Wall Pipe, Galvanized P58-12 12" Section Double Wall Pipe, Galvanized P58-24 24" Section Double Wall Pipe, Galvanized P58-36 36" Section Double Wall Pipe, Galvanized P58-48 48" Section Double Wall Pipe, Galvanized PA58-712 Adjustable 7"-12" Section Double
If area above is a living space, install
firestop below framed hole.
Figure 16 - Installing Firestop
Wall Pipe, Galvanized E58-45 45° Elbow, Galvanized E58-90 90° Elbow, Galvanized HTS-58 Horizontal Square Termination, Galvanized HHT-58 High Wind Round Termination, Galvanized VT-58 Vertical Round Termination, Galvanized SC-58 Storm Collar, Galvanized WF-58 Wall Firestop, Galvanized RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,
Vertical Venting V = 40' max.
Galvanized VR-58 Vertical Restrictor, Galvanized S-58 Vinyl Siding Standoff, Galvanized WS-58 Wall Strap CS-58 Cathedral Ceiling Support FP-58 Firestop Plate SF-58 Stucco Flashing - For use with HTS-58 RF-58 Flat Roof Flashing
Figure 17 - Vertical Venting Configuration

Fireplace Installation CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type.
For propane/LP connection only, the installer must supply an external regulator. The exter nal regulator will reduce incoming gas pres sure. You must reduce incoming gas pressure to between 11" and 14" of w.c. pressure. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 18. Pointing the vent down protects it from freezing rain or sleet.
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 19, page 17). IMPORTANT: Install main gas valve (equip ment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.
External Regulator with Vent Pointing Down
Figure 18 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP Supply Tank

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 19. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping sys tem between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sedi ment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.
Equipment Shutoff Valve with 1/8" NPT Tap*
Natural - From Gas Meter (5.5" W.C. to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Figure 19 - Gas Connection
* The equipment shutoff valve may be sup plied with the appliance or you can purchase it from your retailer.
Red Surface Indicates For Propane/LP Use Only Pilot Adjustment

1/2" NPT Incoming Gas Line Note: 1) Wire connections not shown for clarity 2) * 1/8" NPT Plugged Tapping
Figure 20 - Connecting Incoming Gas Line to Flex Gas Line
Sediment Trap/ · Drip Leg · Inlet Pressure Tap


Figure 21 - Equipment Shutoff Valve
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equip ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 4. Check all joints of gas supply piping sys tem. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check recon nected fittings for leaks.


Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig ure 21). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air.
Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Fig ure 21). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

Removing Glass Door If replacement of glass is necessary, the entire frame assembly must be replaced. Gloves must be worn when removing/replacing glass door. If glass is broken tape remaining glass onto frame before removing. 1. Remove screens if installed. 2. Open bottom access panel. 3. Unlock 2 door latches on bottom of firebox. 4. Tilt open glass door 45° from the bottom of firebox and lift up to release door from firebox top retainer (see Figure 24).
Bottom Access Panel Door Latches
Figure 24 - Removing/Replacing Door
Replacing Glass Door 1. Position door frame in front of firebox opening with bottom of door tilted away from firebox (see Figure 24). 2. Hook top flange of door frame over top of firebox frame. 3. Secure 2 bottom door latches.
Door Retainer · Glass Door

Lava Rock, Decorative Grate, Ember Flakes and Scrap Log Installation Lava rock, ember flakes and scrap log pieces are included with your fireplace. Install these items while glass doors are open and/or removed. 1. Follow instructions from Removing/Re placing Glass Door, page 19, to move glass out of the way of this installation. 2. For 36" models only, install 3 loose logs by placing log #1, log #2 and log #3 onto one piece log as shown in Figure 25. 3. Place lava rock around base of burner. Make sure burner ports are not covered (see Figure 26). 4. Place ember flakes around front and sides of burner and on burner ports (see Figure 27). This will create the glowing ember appearance as the flame touches the ember flakes. Do not block burner ports or pilot ports by overlapping ember flakes in one area. It is not necessary to use all ember material provided. 5. Place scrap log pieces randomly behind grate as shown in Figure 28 on lava rock and around (but not on) burner ports. 6. Place grate in front of logs as shown in Figure 28. Be sure grate is balanced so it does not fall or lean onto logs. Grate does not attach to hearth assembly.

Figure 26 - Installing Lava Rock

Figure 27 - Installing Ember Flakes

Log #1 Log #3

Figure 28 - Installing Scrap Log Pieces
Connecting and Disconnecting Gas Line

Figure 25 - Installing Loose Logs
Ember Flakes · Log #2 · Scrap Log Pieces


Installing Batteries in Remote Receiver 1. Open bottom access door. 2. Remove switch plate from receiver (see Figure 31). 3. Remove battery housing cover on remote receiver to expose battery housing (see Figure 31). 4. Install 4 AA batteries into housing follow ing positive and negative directions on battery housing cover removed in step 3 (see Figure 31). 5. Replace battery housing cover and switch plate. 6. Install 2 D batteries into AC backup battery pack. 7. Close bottom access door.
1. Remove glass door (see page 19). 2. Remove grate and all floor media (see page 20). 3. Carefully lift and remove 3 hearth refrac tories from fireplace. 4. Remove 3 spacers from firebox bottom (see Figure 30). 5. For 36" models only, remove 3 loose logs from log set (see Figure 25 page 20). 6. Remove 9 screws from front and sides of firebox burner base. Lift entire base from unit by pulling forward to disengage from rear flange and then lifting up (see Figure 30). 7. If needed, replace burner gasket before reinstalling log set/burner module (see replacement parts list on page 36.)

To Gas Supply (Natural)

To External Regulator (Propane/LP)
D Batteries Switch Plate
Figure 31 - Installing Receiver Batteries
Figure 29 - Connecting/Disconnecting
Gas Line to Millivolt Valve
(Included)

Installing Batteries in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit.
Battery Cover Remote Control Unit
Figure 32 - Installing Battery in Hand-Held Remote Control Unit
(use only alkaline batteries, not included)
C. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
A. This appliance is equipped with an igni
tion device which automatically lights the pilot. Do not light pilot by hand. B. BEFORE LIGHTING smell all around
AAA Batteries · Battery Housing

TO APPLIANCE 1. Turn off safety shutoff switch. 2. Turn off all electric power to appliance if service is to be performed. 3. Remove center brick/control cover. 4. Turn equipment shutoff valve clockwise to OFF. Do not force. 5. Replace center brick/control cover.
REMOTE OPERATION 1. Turn equipment shutoff valve to ON posi tion. You can now turn the burner on and off with hand-held remote control unit. IMPORTANT: Be sure to press ON/OFF buttons on hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press ON/OFF button to turn burner on and off.
IN OUT
IN
PILOT
TH
TP
TH TP
Figure 33 - Turning Equipment Shutoff Valve to the OFF Position
Figure 34 - Pilot

Check pilot flame pattern and burner flame patterns often.
Pilot Burner Ignitor/ Sensor
Figure 36 - Typical Flame Pattern
Figure 35 - Correct Pilot Flame Pattern
Sensing Rod

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household clean er and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door, page 19 of this manual when removing glass door for cleaning.
Venting system Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced im mediately by a qualified service person. 2. Remove the vent cap and shine a flash light into the vent. Remove any foreign material. 3. Check for evidence of excessive con densation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather. 4. Inspect joints to verify that no pipe section or fitting has been disturbed and loos ened. Check mechanical supports such as wall straps for rigidity.
If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 19). Vacuum all glass pieces with a shop vac.
Use only glass door replacement intended for this fireplace (see Replacement Parts, page 36 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 19 for instructions for re placing glass doors.

POSSIBLE CAUSE
REMEDY
Ignitor will not spark or pilot will not light
1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after re peated attempts appliance does not light, call for quali fied service and repair 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (Re fer to Replacement Parts, page 36) 7. Check that main power is on and that all wire connec tions are made correctly to ignition model (see Wiring Diagram, page 29). Check for 24 VAC at the second ary side of transformer. If 24 VAC is present and module does not operate, have module replaced. Other wise have transformer re placed

POSSIBLE CAUSE
REMEDY
Pilot will not stay lit
No gas to burner, although safety shutoff switch and valve are set to the ON position
Fireplace produces a clicking/ ticking noise just after burner is lit or shut off
Slight smoke or odor during initial operation
Frequent pilot outage

POSSIBLE CAUSE
REMEDY
Gas odor even when gas control valve is off
Gas odor during combustion
Dark residue on logs or inside of fireplace
Glass soots

I S
PILOT CONNECTORS
BATTERY PACK
CONTROL MODULE
VALVE
"D" SIZE
"D" SIZE
THTP
Yl Gn Bn Bk Og Bk Bk Bn Bu Bu
TH
Red Bu Yl Bu Bk Og Gn
BATTERY
RELAY
TO J-BOX
4 "AA" SIZE BATTERY
ADAPTER

Models (V)dvf36ns, (V)dvf36ps, (V)dvf36nh, (V)dvf36ph, dvf-36ns- ha, dvf36nh-ha, (V)dvf42ns, (V)dvf42ps, (V)dvf42nh, (V)dvf42ph, dvf-42ns-ha, and dvf42nh-ha


PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 36 of this manual.
(V)DVF36P(H,S)
(V)DVF42N(H,S)
(V)DVF42P(H,S)
DVF36N(H,S)-HA
DVF42N(H,S)-HA

Burner Assembly Models (V)dvf36ns, (V)dvf36ps, (V)dvf36nh, (V) dvf36ph, dvf-36ns-ha, dvf36nh-ha, (V)dvf42ns, (V)dvf42ps, (V) dvf42nh, (V)dvf42ph, dvf-42ns-ha, and dvf42nh-ha


Burner Assembly This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 36 of this manual.
(V) DVF36P(H,S)
(V)DVF42N(H,S)
(V)DVF42P(H,S)
DVF36N(H,S)-HA
DVF42N(H,S)-HA



DVF42(N,P)H(-HA)
DVF36(N,P)H(-HA)
DVF42(N,P)S(-HA)
DVF36(N,P)S(-HA)
VDVF42(N,P)H
VDVF36(N,P)H
VDVF42(N,P)S
VDVF36(N,P)S

Technical Service You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready. You can also visit our web site at www.fmiproducts.com.
Accessories Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the ad dress listed on the back page of this manual.
Propane/Natural Gas Conversion Kit IMPORTANT: NOT to be used for High Altitude (-HA) Models PCD-36S - Propane/LP Gas Conversion Kit NCD-36S - Natural Gas Conversion Kit PCD-42S - Propane/LP Gas Conversion Kit NCD-42S - Natural Gas Conversion Kit
Brick Perimeter Trim Kit PBS36 - Red VPBS36 - Ivory PBS42 - Red VPBS42 - Ivory Magnetic attachment, Matching refractory brick facing surround kit.




Model (located on product or identification tag)
Serial No. (located on product or identification tag)
Keep receipt for warranty verification.
New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
Terms Common to All Warranties The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For information about this warranty contact:
2701 S. Harbor Blvd. Santa Ana, CA 92704
1-866-328-4537 www.fmiproducts.com
125078-01 Rev. B 3/10