Every effort has been made to ensure the accuracy of this document. However, 8e6 Technologies makes no war ranties with respect to this documentation and disclaims any implied warranties of merchantability and fitness for a particular purpose. 8e6 Technologies shall not be liable for any error or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual or the examples herein. The information in this documentation is subject to change without notice.
Other product names mentioned in this manual may be trademarks or registered trademarks of their respective com panies and are the sole property of their respective manufacturers.
ii 8e6 Threat A nalysis R eporter Quick S tart Guide
Trademarks · Part# TAR-QSG-070618


Thank you for choosing to evaluate the 8e6 Technologies Threat Analysis Reporter. This product addresses user-generated Web threats such as excessive use of bandwidth and inappropriate Internet usage, and provides network administrators tools to monitor such threats so management can enforce corporate Internet usage policies.
Working in conjunction with 8e6’s R3000 Enterprise Filter, the Threat Analysis Reporter translates end user Internet activity from the R3000’s logs into dynamic graphical snap shots of network Internet traffic. Using remediation tools in the console, administrators and management can then manage and control user-generated Web threats in real time.
8e6 Threat A nalysis R eporter Quick S tart Guide 1

This document is divided into the following sections:
Introduction - This section is comprised of an overview of the Threat Analysis Re porter product and how to use this document
Service Information - This section provides 8e6 Technologies contact information
Preliminary Setup Procedures - This section includes instructions on how to physi cally set up the Threat Analysis Reporter unit in your network environment
Install the Server - This section explains how to configure the Threat Analysis Re porter
Conclusion - This section indicates that the quick start steps have been completed
Specifications - This section features hardware specifications and descriptions of front panel LED indicators
Appendix: Optional Ethernet Tap Installation - This appendix explains how to install the optional Ethernet Tap device on your network for bandwidth monitoring if you have a TAR “S” or TAR “H” server
The following icons are used throughout this document to call attention to important information pertaining to handling, operation, and maintenance of the server; safety and preservation of the equipment, and personal safety:
2 8e6 Threat A nalysis R eporter Quick S tart Guide

The user should not attempt any maintenance or service on the unit beyond the proce dures outlined in this document.
Any initial hardware setup problem that cannot be resolved at your internal organiza tion should be referred to an 8e6 Technologies solutions engineer or technical support representative.
When calling 8e6 Technologies regarding a problem, please provide the representative the following information:
Your contact information.
Serial number or original order number.
Description of the problem.
Network environment in which the unit is used.
State of the unit before the problem occurred.
Frequency and repeatability of the problem.
Can the product continue to operate with this problem?
Can you identify anything that may have caused the problem?
8e6 Threat A nalysis R eporter Quick S tart Guide 3

Unpack the Unit from the Carton
Inspect the packaging container for evidence of mishandling during transit. If the packag ing container is damaged, photograph it for reference.
Carefully unpack the unit from the carton and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Tech nologies.
The carton should contain the following items:
1 Threat Analysis Reporter unit 1 AC Power Cord 1 Serial Port Cable 1 CAT-5E Crossover Cable 1 CAT-5E Coupler Rack Mount Brackets (2) 1 End User License Agreement (EULA) 1 envelope containing a CD-ROM with a PDF of the Threat Analysis Reporter User Guide. The latest version of the user guide can be obtained from our Web site at http://www.8e6.com/docs/tar_ug.pdf.
Inspect the server and accessories for damage. If the contents appear damaged, file a damage claim with the carrier immediately.
For “S” and “MSA” units, proceed to the instructions for Rack Mount the “S” or “MSA” Server.
For “H” units, proceed to the instructions for Install the “H” Server Bezel, followed by Rack Mount the “H” Server.
4 8e6 Threat A nalysis R eporter Quick S tart Guide

Determine the placement of each component in the rack before you install the rails. Install the heaviest server components on the bottom of the rack first, and then work up.
You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack rail that secures directly to the rack itself (B). A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail. The A and B rails must be detached from each other in order to install.
To remove the fixed chassis rail (A), pull it out as far as possible. You should hear a “click” sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail.

Position the fixed chassis rail sections you just removed along the side of the server chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis. Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a Telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming com pletely out of the rack when you pull it out for servicing.
8e6 Threat A nalysis R eporter Quick S tart Guide 5
• •

Determine where you want to place the server unit in the rack. Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.

You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).

8e6 Threat A nalysis R eporter Quick S tart Guide

If you are installing the 8e6 server unit into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation pro cedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the Telco rack.

8e6 Threat A nalysis R eporter Quick S tart Guide 7

Before rack mounting the “H” unit, the bezel should be installed on the front end of the chassis. This portion of the installation process requires you to unpack the unit and be zel.



Outside of left inner rail Inside front end of left inner


Inner left rail attached to chassis Pin on right side of bezel
8e6 Threat A nalysis R eporter Quick S tart Guide
Front of bezel · rail

A. Remove the plastic wrapping from the left and

right ears.
B. On one side of the chassis (left or right), un

screw the inner rail from the chassis.
C. Slide the loosened inner rail slightly backwards

to release it from the clips at the side of the chassis, and then lay it down beside the chas sis, with the inside of the rail facing up.
D. On the inner rail that is still attached to the

chassis, insert the bezel pin into the bottom hole of the ear. Be sure the pin is pushed all the way in so that it is flush against the ear.
E. Take up the free end of the bezel and also the

loosened inner rail.
8e6 Threat A nalysis R eporter Quick S tart Guide 9

F. Return the loosened inner rail to its upright po

sition and insert the bezel pin into the bottom hole of the ear.
G. Slide the inner rail forward beneath the clips to

lock it in place.
H. Screw the inner rail back on the chassis.
I. After it is installed, the bezel should drop down

when it is gently tugged forward and down ward. The bezel should remain upright when raised up and closed.
10 8e6 Threat A nalysis R eporter Quick S tart Guide

You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack rail that secures directly to the rack itself (B). Two pairs of short brackets to be used on the front side of the outer rails are also included.

Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step.
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. Secure the short bracket to the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws. Repeat these steps for the left outer rail.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extend ed from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
8e6 Threat A nalysis R eporter Quick S tart Guide 11


You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the locking tabs “click.” Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack.

12 8e6 Threat A nalysis R eporter Quick S tart Guide

If you are installing the 8e6 server unit into a Telco type rack, follow the directions given on the previous page for rack installation. The only difference in the installation proce dure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the Telco rack.

8e6 Threat A nalysis R eporter Quick S tart Guide 13

Step 1: Initial Setup Procedures
This step requires you to link the workstation to the Threat Analysis Reporter. The follow ing hardware can be used for the initial setup procedures:
Threat Analysis Reporter unit with AC power cord either one of two options:
PC monitor with AC power cord and keyboard, or PC laptop computer with HyperTerminal and serial port cable (and USB DB9 se rial adapter, if there is no serial port on your laptop)
14 8e6 Threat A nalysis R eporter Quick S tart Guide

A. Connect the PC monitor and keyboard cables to the rear of the chassis.
B. Turn on the PC monitor.
C. Power on the Threat Analysis Reporter unit by dropping down the face plate and
pressing the large button at the right of the front panel (see image below).

Front of the chassis
Once the Threat Analysis Reporter is powered up, proceed to the Step-by-Step Initial Setup Procedures.
A. Using the serial port cable (and USB DB9 serial adapter, if necessary), connect the
laptop to the rear of the chassis (see images below).

Rear of the “S” or “MSA” chassis

Rear of the “H” chassis
B. Power on the laptop.
C. Power on the Threat Analysis Reporter by dropping down the face plate and pressing
the large button at the right of the front panel (see top image on this page).
Once the Threat Analysis Reporter is powered up, proceed to the instructions for Hyper Terminal Setup Procedures.
8e6 Threat A nalysis R eporter Quick S tart Guide 15

If using a serial console, follow these procedures to create a HyperTerminal session.
A. Launch HyperTerminal by going to Start > Programs > Accessories > Communica
tions > HyperTerminal:

B. In the Connection Description dialog box, enter any session Name, and then click
OK to open the Connect To dialog box:

16 8e6 Threat A nalysis R eporter Quick S tart Guide

C. At the Connect using field, select the COM port assigned to the serial port on the
laptop (probably “COM1”), and then click OK to open the Properties dialog box, dis playing the Port Settings tab:

D. Specify the following session settings:
E. Click OK to connect to the HyperTerminal session:

8e6 Threat A nalysis R eporter Quick S tart Guide 17

F. In the HyperTerminal session window, go to File > Properties to open the Properties
dialog box, displaying the Connect To and Settings tabs:

G. Click the Settings tab, and at the Emulation menu select “VT100”.
H. Click OK to close the dialog box, and to go to the login screen.
18 8e6 Threat A nalysis R eporter Quick S tart Guide

For these step-by-step procedures, you will need your network administrator to provide you the LAN 1 (Ethernet 0) and LAN 2 (Ethernet 1) IP address and subnet mask, gate way IP address, DNS server IP address(es), host name of the server, and IP address for the Web interface (if using a NAT device).
The login screen displays after powering on the Threat Analysis Reporter unit using a monitor and keyboard, or after creating a HyperTerminal session.
A. At the login prompt, type in menu.
B. Press the Enter key to display the Password prompt.
C. At the Password prompt, type in the following: #s3tup#r3k
D. Press Enter to display the System Configuration screen:

8e6 Threat A nalysis R eporter Quick S tart Guide 19

E. At the Press the number of your selection prompt, press 2 to display the Adminis
trator Password Entry screen:

F. At the Enter the administrator password prompt, re-enter your password:
G. Press Enter to display the Administration menu where you can begin the step-by-
step initial setup process using the configuration screens:

H. At the Press the number of your selection prompt, press 2 to select the “Initial
Setup step-by-step” process. This process takes you to the Configure Network Inter face screen.
20 8e6 Threat A nalysis R eporter Quick S tart Guide


A. At the Enter interface LAN1 (eth0) IP address field, enter the IP address for the
LAN 1 (Ethernet 0) interface, and then press Enter to go to the next screen.

B. At the Enter interface LAN1 (eth0) netmask field, enter the subnet mask for the
LAN 1 (Ethernet 0) interface using the dotted decimals notation format. Press Enter to display the confirmation prompt.
8e6 Threat A nalysis R eporter Quick S tart Guide 21

C. Press Y for “Yes” to confirm and save your entries for the LAN1 (eth0) interface, and
to go to the next screen.

D. At the Enter interface LAN2 (eth1) IP address field, enter the IP address for the
LAN 2 (Ethernet 1) interface, and then press Enter to go to the next screen.

E. At the Enter interface LAN2 (eth1) netmask field, using the dotted decimals nota
tion format, enter the subnet mask for the LAN 2 (Ethernet 1) interface. Press Enter to display the confirmation prompt.
F. Press Y for “Yes” to confirm and save your entries for the eth1 interface, and to go to
the Configure default gateway screen.
22 8e6 Threat A nalysis R eporter Quick S tart Guide


A. At the Enter default gateway IP field, enter the IP address for the default gateway.
Press Enter to display the confirmation prompt.
B. Press Y for “Yes” to confirm and save your entry for the gateway IP address, and to
go to the Configure Domain Name Servers screen.

8e6 Threat A nalysis R eporter Quick S tart Guide 23

A. At the Enter first DNS server IP field, enter the IP address for the primary Domain
Name Server. Press Enter to go to the next screen.

B. At the Enter (optional) second DNS server IP field, if you have a secondary Do
main Name Server you wish to use, enter the IP address for that server. Press Enter to display the confirmation prompt.
C. Press Y for “Yes” to confirm and save your entries for the domain name servers, and
to go to the Configure Host Name screen.

24 8e6 Threat A nalysis R eporter Quick S tart Guide

A. At the Enter host name field, enter the host name of the server. Press Enter to dis
play the confirmation prompt.
B. Press Y for “Yes” to confirm and save your entry for the host name, and to go to the
Time zone regional configuration screen.

A. Use the up and down arrows in your keyboard to select your region. After selecting
your locality, press Y for “Yes” to confirm and save your regional selection, and to go to the next screen:

8e6 Threat A nalysis R eporter Quick S tart Guide 25

B. Use the up and down arrows in your keyboard to select your region. After selecting
your locality, press Y for “Yes” to confirm and save your regional selection, and to go to the Configure Wizard user screen.

A. At the Enter wizard user name field, enter the username that will be used to access
the setup wizard in the Threat Analysis Reporter interface. Press Enter to display the confirmation prompt.
B. Press Y for “Yes” to confirm and save your entry and to go to the next screen.

26 8e6 Threat A nalysis R eporter Quick S tart Guide

C. At the Enter wizard password field, enter the password that will be used to access
the setup wizard in the Threat Analysis Reporter interface. Press Y for “Yes” to con firm and save your entry and to go to the Setup Wizard Confirmation screen.

Press Y for “Yes” to save all your wizard entries and to return to the Administration menu.
After making all entries using the step-by-step initial setup process, you will return to the Administration menu. Press X to return to the System Configuration screen. Or, to verify the status of the Threat Analysis Reporter and review the entries you made using the wizard, press 1 to view the System Status screen.
8e6 Threat A nalysis R eporter Quick S tart Guide 27


The System Status screen contains the following information:
LAN1 (eth0) interface for web access and R3000 communications: LAN1 (eth0) IP address and netmask specified in screen 3 (Configure Network Interface), and current status (“Active” or “Inactive”) LAN2 (eth1) interface for bandwidth monitoring: LAN2 (eth1) IP address and netmask specified in screen 4 (Configure Network Interface), and current status (“Active” or “Inactive”) Default gateway IP address specified in screen 5 (Configure default gateway) Configure host name specified in screen 7 (Configure Host Name) DNS server IP address(es) specified in screen 6 (Configure Domain Name Servers) Current status of the Threat Analysis Reporter Current Version of the Threat Analysis Reporter software
• • • • •
A. After completing the wizard setup procedures, return to the System Configuration
screen and press 9 to log out.
B. Disconnect the peripherals from the Threat Analysis Reporter.
28 8e6 Threat A nalysis R eporter Quick S tart Guide

After performing initial setup procedures for the Threat Analysis Reporter, the unit should be physically connected to the network. This step requires a standard CAT-5E cable to connect the unit to the network. An additional CAT-5E cable is required if the Ethernet Tap unit will be installed for bandwidth monitoring.
A. Plug one end of a standard CAT-5E cable into the Threat Analysis Reporter’s LAN 1
port, the port on the left.

Rear of the “S” and “MSA” chassis

Rear of the “H” chassis
B. Plug the other end of the CAT-5E cable into an open port on the network switch.
If you choose to install the Ethernet Tap for bandwidth monitoring, you will need to con nect it to the Threat Analysis Reporter at this point. Refer to Appendix A at the end of this document for instructions on how to connect the Ethernet Tap unit.
8e6 Threat A nalysis R eporter Quick S tart Guide 29

For this step, you will need your network administrator to provide you the following infor mation:
IP range and netmask of machines on the network the Threat Analysis Reporter server will be monitoring R3000 IP address, port number to be used between the R3000 and Threat Analysis Reporter, and type of authentication method to be used (IP group or LDAP) 8e6 Enterprise Reporter server IP address and server name, if an ER unit is con nected to the R3000
A. Launch Internet Explorer.
B. In the address field, type in http://x.x.x.x:8080/8e6tar/wizard.html (in which “x.x.x.x”
represents the eth0 IP address entered in the Connect Network Interface screen of the Step-by-Step Initial Setup Procedures). In our example, this entry would be: http://200.100.10.10:8080/8e6tar/wizard.html.
C. Click Go to open the Threat Analysis Reporter interface and the EULA Agreement
dialog box:

30 8e6 Threat A nalysis R eporter Quick S tart Guide

D. After reading the End User License Agreement, you have the option to do either of
the following:
Click No to close both the EULA Agreement dialog box and the Threat Analysis Reporter interface. You will not be able to enable the Threat Analysis Reporter for use in your environment.
Click Yes to close the EULA Agreement dialog box and to open the Login dialog box:

Proceed to the next sub-section: Log in to the Threat Analysis Reporter Adminis trator Console.
A. In the Username field of the Login dialog box, type in the username specified in the
Configure Wizard user screen of the Step-by-Step Initial Setup Procedures. In our example, this entry would be: taruser.
B. In the Password field, type in the password specified in the Configure Wizard user
screen of the Step-by-Step Initial Setup Procedures.
C. Click LOGIN to close the login dialog box and to go to Step 1 of wizard setup pro
cedures in the Threat Analysis Reporter Administrator console (see Step 1: Register administrator).
8e6 Threat A nalysis R eporter Quick S tart Guide 31
• · •

Step 1 is performed in the left side of the first screen of the wizard:

A. Enter the username the global administrator will use when logging into the Threat
Analysis Reporter Administrator console. The global administrator has the highest level of permissions in the Threat Analysis Reporter interface.
B. Enter the password to be used with that username, and enter the same password
again in the confirm password field.
C. Enter the email address of the global administrator, who will be notified via email
when gauges reach their specified upper threshold limits.
32 8e6 Threat A nalysis R eporter Quick S tart Guide

D. Click the [+] Add tab beow to open the IP Range Information dialog box:

E. Enter the IP address range for the bandwidth the Threat Analysis Reporter will moni
tor.
F. Enter the Netmask for the IP range to be monitored, using the dotted decimals nota
tion format.
G. Click OK to close the dialog box and to display your entries in the list box:

8e6 Threat A nalysis R eporter Quick S tart Guide 33

To modify an IP address range, double-click the entry in the list box to highlight it and to display the [-] Remove tab to the left of the [+] Add tab:

To modify the entries made for the IP address range, click the [+] Add tab to re- open the IP Range Information dialog box and edit information, as necessary. Click OK to close the dialog box and to display the modified information in the list box.
To remove the entry for the IP address range from the list box, click the [-] Re move tab. Click the [+] Add tab to open the IP Range Information dialog box and make new entries for the IP address range.
34 8e6 Threat A nalysis R eporter Quick S tart Guide
• · •

Step 2 is performed in the right side of the first screen of the wizard.
Specify information for the R3000 to be used with the Threat Analysis Reporter:
A. Click the [+] Add tab above the R3000 list box to open the R3000 Information dialog
box:

B. Enter the IP address of the R3000 server to be used with the Threat Analysis Re
porter. In our example, this is: 200.100.160.74, which is the Ethernet 1 IP address of the R3000 server.
C. Enter the Server Name of the R3000 to be used with the Threat Analysis Reporter,
which is any name you wish to associate with that R3000. In our example, this is: R3000LOGO.
D. Respond to the question “Is this your Master R3000?” by clicking the “Yes” checkbox,
if this R3000 will be designated the master R3000 to be associated with the Threat Analysis Reporter. Otherwise, leave the checkbox blank.
8e6 Threat A nalysis R eporter Quick S tart Guide 35

E. Click OK to close the dialog box and to display your entries in the list box:

To modify an R3000 entry, double-click the R3000 entry in the list box to highlight it and to display the Set as Master tab and the [-] Remove tab to the left of the [+] Add tab:

36 8e6 Threat A nalysis R eporter Quick S tart Guide

To modify the IP address and Server Name for the R3000 server, click the [+] Add tab to re-open the R3000 Information dialog box, and edit information as necessary. Click OK to close the dialog box and to display the modified informa tion in the list box.
To designate an R3000 as the Master R3000 server, click the entry for the R3000 server in the list box to highlight it, and then click the Set as Master tab to display “Master” in the Master column for that entry in the list box.
To remove the entry for the R3000 server from the list box, click the [-] Remove tab.
F. Specify the User Authentication method to be used for monitoring activity on the

Respond to the question “Do you have an Enterprise Reporter?” by clicking the radio button corresponding to either “Yes” or “No”.
If “No” was selected, click NEXT > at the bottom right of the screen to go to Step 3.
If “Yes” was selected, the IP address and Server Name fields display in place of the radio buttons. The < Back button displays above the Server Name field.
8e6 Threat A nalysis R eporter Quick S tart Guide 37


A. Enter the IP address of the ER server to be used with the Threat Analysis Re
porter. In our example, this is: 200.10.101.76.
B. Enter the Server Name of the ER server to be used with the Threat Analysis
Reporter. In our example, this is: er4logo.
C. Click NEXT > at the bottom right of the screen to go to Step 3.
38 8e6 Threat A nalysis R eporter Quick S tart Guide

Step 3 requires you to specify settings for default gauges to be monitored by the Threat Analysis Reporter. These gauges will display in the Threat Analysis Reporter interface upon logging into the Administrator console.

By default, all Gauges displayed in this wizard screen (Adult Content, Security, Shop ping, Bandwidth, Illegal) are selected for monitoring. To deselect a gauge from the Gauge Groups list, remove the checkmark by clicking the checkbox in the Selected column corresponding to that gauge.
8e6 Threat A nalysis R eporter Quick S tart Guide 39

To view gauge components for a specified gauge, highlight and double-click the gauge name to populate the the fields to the right of the Gauge Groups list box.

The following gauge criteria can be edited:
Name: The displayed gauge name to be used in the interface can be modified by making an entry in this field.
Lower Limit: The default amount (“0” or zero) that will represent the lower end of the gauge can be adjusted to accommodate the type of activity to be monitored on your network.
Higher Limit: The default amount (“200”) that will represent the higher end of the gauge can be adjusted to accommodate the type of activity to be monitored on your network.
Gauge Components: To remove a gauge component, go to the Selected column and click the checkmark in the checkbox corresponding to the component to be removed.
Click NEXT > at the bottom right of the screen to go to Step 4.
iv 8e6 Threat A nalysis R eporter Quick S tart Guide

In Step 4, the following R3000 server information displays: Active Directory Settings, SMTP Server Settings, Patch Server Settings, PROXY Server Settings, NTP Server Set tings:

After reviewing the information in this screen, the following actions can now be per formed:
To print this information, click the Print button.
To save all settings entered during the wizard process, click Save. After your infor mation is saved, the login dialog box of the Threat Analysis Reporter interface dis plays, and you can begin using the application.
8e6 Threat A nalysis R eporter Quick S tart Guide 41
• · •

Congratulations; you have completed the Threat Analysis Reporter quick start proce dures. Now that the Threat Analysis Reporter is running on your network, the next step is to set up user groups or administrator groups. You will set up and configure gauges thereafter.
Obtain the latest Threat Analysis Reporter User Guide from our Web site at http:// www.8e6.com/docs/tar_ug.pdf.
iv 8e6 Threat A nalysis R eporter Quick S tart Guide

Physical Specifications

Specification “S” Value “H” Value “MSA” Value Height 1.7” (43mm) 1.7” (43mm) 1.7” (43mm) Width 16.8” (426mm) 17.2” (438mm) 16.8” (426mm) Depth 22.6” (574mm) 26.8” (681mm) 14.0” (356mm) Front clearance 2 inches (76mm) 2 inches (76mm) 2 inches (76mm) Side clearance 1 inch (25mm) 1 inch (25mm) 1 inch (25mm) Rear clearance 3.6 inches (92mm) 3.6 inches (92mm) 3.6 inches (92mm) Weight 19.5 lbs (8.85 kg) 43.0 lbs (19.5 kg) 11 lbs, 5 oz (5.13 kg)


Specification “S” Value “H” Value “MSA” Value CPU 2.0GHz P4 CPU 2x3.6GHz Xeon CPU 2.0GHz Celeron CPU Memory 3GB PC4200 / DDR2-533 Dual Channel ECC RAM
3GB PC2700 / DDR- 333 ECC SDRAM 3GB PC2700 / DDR- 333 Dual Channel RAM Hard drive capacity 1x250GB HDD 2x250GB HDD 1x250GB HDD
8e6 Threat A nalysis R eporter Quick S tart Guide 43

10° C ~ 35° C (50° F ~ 95° F)
10° C ~ 35° C (50° F ~ 95° F)
10° C ~ 35° C (50° F ~ 95° F)
Storage temperature range -40° C ~ +60° C (- 40° F ~ 158° F) -40° C ~ +60° C (- 40° F ~ 158° F) -40° C ~ +70° C (- 40° F ~ 158° F)
Operating humidity range 8 ~ 90% non-con densing
8 ~ 90% non-con densing
8 ~ 90% non-con densing
Storage humidity range 5 ~ 95% non-con densing
5 ~ 95% non-con densing
5 ~ 95% non-con densing
Power supply 260W AC power supply [24-pin, (4-pin = 12V)]
560W Hot-swap redundant AC power supply with PFC [ 24-pin, (8-pin = 12V) ]
Thermal control 260W AC power supply with PFC [ 24-pin, (4-pin = 12V) ]
Rated AC input voltage 100 ~ 240V, 50/60Hz, 5-3 Amp 100 ~ 240V, 60- 50Hz, 10-5 Amp per power supply module (two mod ules included in the chassis)
100 ~ 240V, 60- 50Hz, 5-3 Amp
Rated input frequency 50 ~ 60 Hz 50 ~ 60 Hz 50 ~ 60 Hz
Rated input current 5A MAX 10A (115V) to 5A (230V)
Rated output power 260W 560W 260W
Maximum rated BTU 1370 BTUs/Hr N/A (see specs below)
N/A (see specs below)
Regulatory (power supply) Power Supply Safety / EMC USA - UL listed, FCC Canada - CUL listed Germany - TUV Certified Europe/CE Mark EN 60950/IEC 60950-Compliant
EN 60950/IEC 60950-Compliant UL Listed (USA) CUL Listed (Can ada) TUV Certified (Ger many)
USA - UL listed, FCC Canada - CUL listed Germany - TUV Certified Europe/CE Mark EN 60950/IEC 60950-Compliant
iv 8e6 Threat A nalysis R eporter Quick S tart Guide
Operating temperature range

On “S” and “MSA” units, LED indicators and buttons display on the front panel to the right:

LED indicators alert you to the status of a feature on the unit while buttons let you per form a function on the unit.
A. Power F. Reset
B. HDD Activity G. Power
D. LAN 2
E. Overheat
Power Green On System On
HDD Amber Blinking HDD Activity
Off No HDD Activity
LAN 1 & LAN 2 Green On Link Connected
Overheat Red On System Overheated
8e6 Threat A nalysis R eporter Quick S tart Guide 45

Tap Installation
This appendix pertains to the optional installation of the Ethernet Tap unit for bandwidth monitoring.
Open the NetOptics Ethernet Tap box and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Technologies.
The NetOptics box should contain the following items:
1 NetOptics 10/100BaseT Tap 2 Power Supply units 2 AC Power cords 2 Crossover cables 2 Straight through cables 1 Installation Guide
In addition to the contents of the NetOptics box, you will need the following item to install the Ethernet Tap unit:
1 Standard CAT-5E cable
Inspect the box for damage. If the contents appear damaged, file a damage claim with the carrier immediately.
46 8e6 Threat A nalysis R eporter Quick S tart Guide
46 8e6 Threat A nalysis R eporter Quick S tart Guide
•

Tap Installation

Diagram showing TAR Ethernet Tap installation on the network
This step is a continuation from Step 2: Physically Connect the Unit to the Network. The procedures outlined in this step require the use of a CAT-5E cable.
A. Provide power to the Ethernet Tap by connecting both power cords from the unit to
the power source.

AC power in rear panel of NetOptics 10/100BaseT Tap
B. If a designated master R3000 (to be used with the Threat Analysis Reporter) is al
ready installed on the network, disconnect the cable that connects this R3000 to the switch.
If the designated R3000 has not yet been installed, disregard this sub-step and pro ceed to sub-step C.
8e6 Threat A nalysis R eporter Quick S tart Guide 47
8e6 Threat A nalysis R eporter Quick S tart Guide 47

Tap Installation
C. Using a crossover cable, connect one end to the Switch’s port configured to be the
destination port of the Port Mirror.
If adding a Threat Analysis Reporter to an existing installation, this port would be the port that was originally occupied by the listening interface of the R3000.
D. Connect the other end of the crossover cable to the Ethernet Tap’s Network A port.

Ports in front panel of NetOptics 10/100BaseT Tap
E. Using a straight through cable, connect one end to the Ethernet Tap’s Network B
port.
F. Connect the other end of the straight through cable to the R3000’s listening interface.
G. Using the second straight through cable, connect one end to the Ethernet Tap’s
Monitor A port.
H. Connect the other end of the second straight through cable to the Threat Analysis
Reporter’s listening interface.
Proceed to Step 3: Wizard Setup Procedures of the Threat Analysis Reporter installation instructions.
48 8e6 Threat A nalysis R eporter Quick S tart Guide
48 8e6 Threat A nalysis R eporter Quick S tart Guide

Tap Installation
8e6 Threat A nalysis R eporter Quick S tart Guide 49
8e6 Threat A nalysis R eporter Quick S tart Guide 49

Satellite Office: 8e6 Taiwan: RM B2, 13F, No. 49, Sec. 3, Minsheng E. Rd., Taipei 104, Taiwan, R.O.C. Tel: 886-2-2501-5285 • Fax: 886-2-2501-5316
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.