8e6 Technologies TAR

76 pages·4.7 MB·Network Card·PDF·ENDEFRITNLJA
8e6 Technologies TAR
Table of Contents 27 sections Contents · Threat Analysis Reporter Introduction · About this Document · Conventions Used in this Document · … ShowHide
Page 1 of the 8e6 Technologies TAR user manual — Release: 1.2.00 / Updated: 09.19.08
Page 1 · click to enlarge
Page 1
8e6 Technologies TAR diagram (page 1)
Fig. 1

QUICK START

GUIDE

8e6 Technologies TAR — QUICK START diagram (page 1)
Fig. 2

Model: TAR HL-005-004, SL-004-004, MSA-004-004

Release: 1.2.00 / Updated: 09.19.08

Threat Analysis Reporter · ®

Page 2 of the 8e6 Technologies TAR user manual
Page 2 · click to enlarge
Page 2

8e6 Threat Analysis Reporter Quick Start Guide

© 2008 8e6 Technologies. All rights reserved.

This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any elec tronic medium or machine readable form without prior written consent from 8e6 Technologies.

Every effort has been made to ensure the accuracy of this document. However, 8e6 Technologies makes no war ranties with respect to this documentation and disclaims any implied warranties of merchantability and fitness for a particular purpose. 8e6 Technologies shall not be liable for any error or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual or the examples herein. The information in this documentation is subject to change without notice.

The Threat Analysis Reporter products have been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Other product names mentioned in this manual may be trademarks or registered trademarks of their respective com panies and are the sole property of their respective manufacturers.

ii 8e6 Threat A nalysis R eporter Quick S tart Guide

Trademarks · Part# TARul-QSG-080919

Page 5 of the 8e6 Technologies TAR user manual — T hreat A nalysis R eporter I ntroduction
Page 5 · click to enlarge
Page 5

T hreat A nalysis R eporter I ntroduction

Thank you for choosing to evaluate the 8e6 Technologies Threat Analysis Reporter. This product addresses user-generated Web threats such as excessive use of bandwidth and inappropriate Internet usage, and provides network administrators tools to monitor such threats so management can enforce corporate Internet usage policies.

Working in conjunction with 8e6’s R3000 Enterprise Filter, the Threat Analysis Reporter translates end user Internet activity from the R3000’s logs into dynamic graphical snap shots of network Internet traffic. Using remediation tools in the console, administrators and management can then manage and control user-generated Web threats in real time.

The TAR HL and SL server models include RAID technology for fault tolerance and high performance.

8e6 Threat A nalysis R eporter Quick S tart Guide 1

Page 6 of the 8e6 Technologies TAR user manual — Conventions Used in this Document
Page 6 · click to enlarge
Page 6

About this Document

This document is divided into the following sections:

Introduction - This section is comprised of an overview of the Threat Analysis Re porter product and how to use this document

Service Information - This section provides 8e6 Technologies contact information

Preliminary Setup Procedures - This section includes instructions on how to physi cally set up the Threat Analysis Reporter unit in your network environment

Install the Server - This section explains how to configure the Threat Analysis Re porter

Conclusion - This section indicates that the quick start steps have been completed

LED Indicators and Buttons - This section explains how to read LED indicators and use LED buttons for troubleshooting the unit

Regulatory Specifications and Disclaimers - This section cites safety and emis sions compliance information for the TAR models referenced in this document

Appendix: Optional Ethernet Tap Installation - This appendix explains how to install the optional Ethernet Tap device on your network for bandwidth monitoring

Index - An alphabetized list of some topics included in this document

Conventions Used in this Document

The following icons are used throughout this document to call attention to important information pertaining to handling, operation, and maintenance of the server; safety and preservation of the equipment, and personal safety:

2 8e6 Threat A nalysis R eporter Quick S tart Guide

Show 9 more labels / short text on this page
• · • · • · • · • · • · • · • · •
Page 7 of the 8e6 Technologies TAR user manual — Procedures
Page 7 · click to enlarge
Page 7

S ervice I nformation

The user should not attempt any maintenance or service on the unit beyond the proce dures outlined in this document.

Any initial hardware setup problem that cannot be resolved at your internal organiza tion should be referred to an 8e6 Technologies solutions engineer or technical support representative.

8e6 Corporate Headquarters (USA)

Local714.282.6111 Domestic US : 1.888.786.7999 International : +1.714.282.6111

8e6 Taiwan

Taipei Local2397-0300 Domestic Taiwan : 02-2397-0300 International : 886-2-2397-0300

Procedures

When calling 8e6 Technologies regarding a problem, please provide the representative the following information:

Your contact information.

Serial number or original order number.

Description of the problem.

Network environment in which the unit is used.

State of the unit before the problem occurred.

Frequency and repeatability of the problem.

Can the product continue to operate with this problem?

Can you identify anything that may have caused the problem?

8e6 Threat A nalysis R eporter Quick S tart Guide 3

Show 8 more labels / short text on this page
• · • · • · • · • · • · • · •
Page 8 of the 8e6 Technologies TAR user manual — P reliminary S etup P rocedures
Page 8 · click to enlarge
Page 8

P reliminary S etup P rocedures

Unpack the Unit from the Carton

Inspect the packaging container for evidence of mishandling during transit. If the packag ing container is damaged, photograph it for reference.

Carefully unpack the unit from the carton and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Tech nologies.

The carton should contain the following items:

1 Threat Analysis Reporter unit 1 AC Power Cord, 2 AC Power Cords for HL servers 1 Serial Port Cable 1 CAT-5E Crossover Cable Rack Mount Brackets (2) 1 End User License Agreement (EULA) 1 envelope containing a CD-ROM with a PDF of the Threat Analysis Reporter User Guide. The latest version of the user guide can be obtained from our Web site at http://www.8e6.com/docs/tar_ug.pdf.

NOTES: A coupler is included in the carton if a three-foot CAT-5E crossover cable is packaged with your unit instead of a 14-foot CAT-5E crossover cable. For HL and SL servers, 1 bezel to be installed on the front of the chassis also is included, as well as 1 spare parts kit. For HL servers, this kit contains a hard drive and power supply. For SL servers, this kit contains a hard drive.

Inspect the server and accessories for damage. If the contents appear damaged, file a damage claim with the carrier immediately.

4 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 9 of the 8e6 Technologies TAR user manual — Select a Site for the Server
Page 9 · click to enlarge
Page 9

Select a Site for the Server

The server operates reliably within normal office environmental limits. Select a site that meets the following criteria:

Clean and relatively free of excess dust.

Well-ventilated and away from sources of heat, with the ventilating openings on the server kept free of obstructions.

Away from sources of vibration or physical shock.

Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators, copy machines, air conditioners, large fans, large electric motors, radio and TV transmitters, and high-frequency security devices.

Access space provided so the server power cord can be unplugged from the power supply or the wall outlet—this is the only way to remove the AC power cord from the server.

Clearance provided for cooling and airflow: Approximately 30 inches (76.2 cm) in the back and 25 inches (63.5 cm) in the front.

Located near a properly earthed, grounded, power outlet.

8e6 Threat A nalysis R eporter Quick S tart Guide 5

Show 7 more labels / short text on this page
• · • · • · • · • · • · •
Page 10 of the 8e6 Technologies TAR user manual — Rack Setup Precautions
Page 10 · click to enlarge
Page 10

Rack Mount the Server

Rack Setup Precautions

Warning:

Before rack mounting the server, the physical environment should be set up to safely ac commodate the server. Be sure that:

The weight of all units in the rack is evenly distributed. Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

The rack will not tip over when the server is mounted, even when the unit is fully extended from the rack.

For a single rack installation, stabilizers are attached to the rack.

For multiple rack installations, racks are coupled together.

Reliable earthing of rack-mounted equipment is maintained at all times. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

A power cord will be long enough to fit into the server when properly mounted in the rack and will be able to supply power to the unit.

The connection of the server to the power supply will not overload any circuits. Con sideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

The server is only connected to a properly rated supply circuit. Reliable earthing (grounding) of rack-mounted equipment should be maintained.

The air flow through the server’s fan or vents is not restricted. Installation of the equipment in a rack should be such that the amount of air flow required for safe op eration of the equipment is not compromised.

The maximum operating ambient temperature does not exceed 104°F (40°C). If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

8e6 Threat A nalysis R eporter Quick S tart Guide

Show 10 more labels / short text on this page
• · • · • · • · • · • · • · • · • · •
Page 11 of the 8e6 Technologies TAR user manual — Install the Outer Rails
Page 11 · click to enlarge
Page 11

Rack Mount Instructions for HL Servers

Rack Setup Suggestions

Determine the placement of each component in the rack before you install the rails. Install the heaviest server components on the bottom of the rack first, and then work up.

Identify the Sections of the Rack Rails

You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack rail that secures directly to the rack itself (B). Two pairs of short brackets to be used on the front side of the outer rails are also included.

8e6 Technologies TAR — Identify the Sections of the Rack Rails diagram (page 11)
Fig. 3 · Identify the Sections of the Rack Rails

Install the Inner Rails

Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step.

Install the Outer Rails

Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. Secure the short bracket to the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws. Repeat these steps for the left outer rail.

8e6 Threat A nalysis R eporter Quick S tart Guide 7

• •

Page 12 of the 8e6 Technologies TAR user manual — Rack Mount the Server
Page 12 · click to enlarge
Page 12

Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully ex tended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.

8e6 Technologies TAR — Rack Mount the Server diagram (page 12)
Fig. 4 · Rack Mount the Server

8e6 Threat A nalysis R eporter Quick S tart Guide

Page 13 of the 8e6 Technologies TAR user manual — Install the Server into the Rack
Page 13 · click to enlarge
Page 13

Install the Server into the Rack

You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).

When the server has been pushed completely into the rack, you should hear the locking tabs “click.”

8e6 Technologies TAR — Install the Server into the Rack diagram (page 13)
Fig. 5 · Install the Server into the Rack

8e6 Threat A nalysis R eporter Quick S tart Guide 9

Page 14 of the 8e6 Technologies TAR user manual — Install the Server into a Telco Rack
Page 14 · click to enlarge
Page 14

Install the Server into a Telco Rack

If you are installing the 8e6 server unit into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will ex tend out the front of the rack. A larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.

8e6 Technologies TAR — Install the Server into a Telco Rack diagram (page 14)
Fig. 6 · Install the Server into a Telco Rack

10 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 15 of the 8e6 Technologies TAR user manual — Install the Outer Slides
Page 15 · click to enlarge
Page 15

Rack Mount Instructions for SL Servers

Rack Setup Suggestions

Determine the placement of each component in the rack before you install the rails. Install the heaviest server components on the bottom of the rack first, and then work up.

Install the Inner Slides

1. Locate the right inner slide, (the slide that will be used on the right side of chassis when facing the front panel of the chassis).
2. Align the four (4) square holes on the right inner slide against the hooks on the right side of the chassis as show below on the left.
3. Securely attach the slide to the chassis with two M4 flat head screws and repeat the steps 1-3 to install the left inner slide to the left side of the chassis.
8e6 Technologies TAR — Install the Inner Slides diagram (page 15)
Fig. 7 · Install the Inner Slides

Install the Outer Slides

1. Measure the distance from the front rail of the rack to the rear rail of the rack.
2. Attach a short bracket to the rear side of the right outer slide, and a long bracket to the front side of the right outer slide as shown above on the right.
3. Adjust the short and long brackets to the proper distance so that the chassis can snugly fit into the rack.
4. Secure the slides to the cabinet with screws.
5. Repeat steps 1-4 for the left outer slide.

8e6 Threat A nalysis R eporter Quick S tart Guide 11

• •

Page 16 of the 8e6 Technologies TAR user manual — Install the Slide Assemblies to the Rack
Page 16 · click to enlarge
Page 16

Install the Slide Assemblies to the Rack

1. After you have installed the short and long brackets to the outer slides, you are ready to install the whole slide assemblies (outer slides with short and long brackets at tached) to the rack. (See the previous page.)
2. Use M5 screws and washers to secure the slide assemblies into the rack as shown below:
8e6 Technologies TAR — Install the Slide Assemblies to the Rack diagram (page 16)
Fig. 8 · Install the Slide Assemblies to the Rack

12 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 17 of the 8e6 Technologies TAR user manual — Install the Chassis into the Rack
Page 17 · click to enlarge
Page 17

Install the Chassis into the Rack

1. Push the inner slides, which are attached to the chassis, into the grooves of the outer slide assemblies that are installed in the rack as shown below:
8e6 Technologies TAR — Install the Chassis into the Rack diagram (page 17)
Fig. 9 · Install the Chassis into the Rack
2. Push the chassis all the way to the back of the outer slide assemblies as shown be low:
8e6 Technologies TAR — Install the Chassis into the Rack diagram (page 17)
Fig. 10 · Install the Chassis into the Rack

8e6 Threat A nalysis R eporter Quick S tart Guide 13

Page 18 of the 8e6 Technologies TAR user manual — Rack Mount Instructions for MSA Servers
Page 18 · click to enlarge
Page 18

Rack Mount Instructions for MSA Servers

Optional: Install the Chassis Rails

  • Before installing the chassis rails:
  • Close the chassis using the chassis cover.
  • Unplug the AC power cord(s).
  • Remove all external devices and connectors.
1. Included in the shipping package are a pair of rail assemblies. In each rail assembly, locate the inner rail and the outer rail.
2. Press the locking tab to release the inner rail from its locking position and pull out the inner rail from the rail assembly.
8e6 Technologies TAR — Rack Mount Instructions for MSA Servers diagram (page 18)
Fig. 11 · Rack Mount Instructions for MSA Servers

14 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 19 of the 8e6 Technologies TAR user manual — Rack Mount the Server
Page 19 · click to enlarge
Page 19
3. Locate the three holes on each side of the chassis and locate the three correspond ing holes on each of the inner rail.
8e6 Technologies TAR — Rack Mount the Server diagram (page 19)
Fig. 12 · Rack Mount the Server
4. Attach an inner rail to each side of the chassis and secure the inner rail to the chas sis by inserting three Type G screws through the holes on each side of the chassis and the inner rail. (See the diagram below for a description of the Type G screw.)
8e6 Technologies TAR — Rack Mount the Server diagram (page 19)
Fig. 13 · Rack Mount the Server
5. Repeat the above steps to install the other rail on the chassis.

8e6 Threat A nalysis R eporter Quick S tart Guide 15

Page 20 of the 8e6 Technologies TAR user manual — Optional: Install the Traditional UP Racks
Page 20 · click to enlarge
Page 20

Optional: Install the Traditional UP Racks

After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack.

  • Determine the placement of each component in the rack before you install

the rails. • Install the heaviest server components on the bottom of the rack first, and

then work up.

1. In the package, locate a pair of front (short) and rear (long) brackets. Please note that the brackets are marked with Up/Front Arrows (front) and Up/Rear arrows (rear).
2. Secure the front (short) bracket (marked with the Up/Front arrows) to the outer rail with two Type G screws. (See the previous page for a description of the Type G screw.)
3. Attach the rear (long) bracket to the other end of the outer rail and secure the rear (long) bracket to the outer rail with a Type G screw as shown below.
4. Measure the depth of your rack and adjust the length of the rails accordingly.
5. Repeat the same steps to install the other outer rail on the chassis.
6. Secure both outer rail assemblies to the rack with Type H screws and Type I wash ers. (See the previous page for descriptions of Type H and Type I hardware compo nents.)
8e6 Technologies TAR — Optional: Install the Traditional UP Racks diagram (page 20)
Fig. 14 · Optional: Install the Traditional UP Racks

16 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 21 of the 8e6 Technologies TAR user manual — Rack Mount the Server
Page 21 · click to enlarge
Page 21
7. Slide the chassis into the rack as shown below.
8. You will need to release the safety taps on both sides of the chassis in order to com pletely remove the chassis out of the rack.
8e6 Technologies TAR — Rack Mount the Server diagram (page 21)
Fig. 15 · Rack Mount the Server

8e6 Threat A nalysis R eporter Quick S tart Guide 17

Page 22 of the 8e6 Technologies TAR user manual — Optional: Install the Open Racks
Page 22 · click to enlarge
Page 22

Optional: Install the Open Racks

After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack.

  • Determine the placement of each component in the rack before you install the rails.
  • Install the heaviest server components on the bottom of the rack first, and then work up.
1. In the package, locate a pair of front (short) and rear (long) brackets. Please note that the brackets are marked with Up/Front Arrows (front) and Up/Rear arrows (rear).
2. Secure the front (short) bracket (marked with the Up/Front arrows) to the outer rail with two Type G screws as shown below.
8e6 Technologies TAR — Optional: Install the Open Racks diagram (page 22)
Fig. 16 · Optional: Install the Open Racks

18 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 23 of the 8e6 Technologies TAR user manual — Rack Mount the Server
Page 23 · click to enlarge
Page 23
3. Attach the front (short) bracket to the front end of the rack, and secure it to the rack with two Type H screws and Type I washers as shown below. (See the previous page for descriptions of Type H and Type I hardware components.)
4. Attach the rear (long) bracket to the rear end of the rack, and secure it to the rack with two Type H screws and Type I washers as shown below. Repeat the same steps to install the other outer rail to the other side of rack.
8e6 Technologies TAR — Rack Mount the Server diagram (page 23)
Fig. 17 · Rack Mount the Server

8e6 Threat A nalysis R eporter Quick S tart Guide 19

Page 24 of the 8e6 Technologies TAR user manual — Rack Mount the Server
Page 24 · click to enlarge
Page 24
5. Measure the depth of your rack and adjust the length of the rails accordingly. Then, secure the rails to the chassis with Type G screws.
6. Slide the inner rails which are attached to the chassis into the outer rails on the rack.
8e6 Technologies TAR — Rack Mount the Server diagram (page 24)
Fig. 18 · Rack Mount the Server

20 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 25 of the 8e6 Technologies TAR user manual — Install the Chassis into the Rack
Page 25 · click to enlarge
Page 25

Install the Chassis into the Rack

  • Make sure that the rack is securely anchored onto an unmovable surface or structure before installing the chassis into the rack.
  • Unplug power cord(s) of the rack before installing the chassis into the rack.
  • Make sure that the system is adequately supported. Make sure that all the components are securely fastened to the chassis to prevent components fall ing off from the chassis.
  • The rack assembly should be properly grounded to avoid electric shock.
  • The rack assembly must provide sufficient airflow to the chassis for proper cooling.
  • Please make sure that all components and all chassis covers are properly in stalled in the chassis before you install the chassis into the racks; otherwise, out-of-warranty damage may occur.

Slide the chassis into the rack and secure it with two screws on each side of the rack as shown in the picture.

8e6 Technologies TAR — Install the Chassis into the Rack diagram (page 25)
Fig. 19 · Install the Chassis into the Rack

8e6 Threat A nalysis R eporter Quick S tart Guide 21

Page 26 of the 8e6 Technologies TAR user manual — Install the SL or HL Server Bezel
Page 26 · click to enlarge
Page 26

Install the SL or HL Server Bezel

After rack mounting an SL or HL server, the bezel should be installed on the front end of the chassis.

A. Hold the bezel upright and facing towards you (Fig. 1).

8e6 Technologies TAR — Install the SL or HL Server Bezel diagram (page 26)
Fig. 20 · Install the SL or HL Server Bezel

Fig. 1 - Front of bezel

B. Note that each end of the bezel contains two raised bumps (Fig. 2).

8e6 Technologies TAR — Install the SL or HL Server Bezel diagram (page 26)
Fig. 21 · Install the SL or HL Server Bezel
8e6 Technologies TAR — Install the SL or HL Server Bezel diagram (page 26)
Fig. 22 · Install the SL or HL Server Bezel

Fig. 2 - Bumps on right end of bezel Fig. 3 - Grooves in right U-shaped handle

C. Align these bumps along the two parallel grooves inside each U-shaped aluminum

chassis handle affixed to the front end of the chassis rail (Fig. 3).

D. Push the bezel towards the front of the chassis, inserting the USB B-type plug on the

back of the bezel (Fig. 4) into the USB port on the chassis.

8e6 Technologies TAR — Install the SL or HL Server Bezel diagram (page 26)
Fig. 23 · Install the SL or HL Server Bezel

Fig. 4 - Section of back of bezel with USB B-type plug

22 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 27 of the 8e6 Technologies TAR user manual — Power Supply Precautions
Page 27 · click to enlarge
Page 27

Check the Power Supply

This server is equipped with a universal power supply that handles 100-240 V, 50/60 Hz. A standard power cord interface (IEC 950) facilitates power plugs that are suitable for most European, North American, and Pacific Rim countries.

Power Supply Precautions

Warning:

Use a regulating uninterruptible power supply (UPS) to protect the server from pow er surges, voltage spikes and to keep the server operating in case of a power failure.

In geographic regions that are susceptible to electrical storms, 8e6 highly recom mends plugging the AC power cord for the server into a surge suppressor.

Use appropriately rated extension cords or power strips only.

Allow power supply units to cool before touching them.

8e6 Threat A nalysis R eporter Quick S tart Guide 23

Show 4 more labels / short text on this page
• · • · • · •
Page 28 of the 8e6 Technologies TAR user manual — Server Operation and Maintenance Precautions
Page 28 · click to enlarge
Page 28

General Safety Information

Server Operation and Maintenance Precautions

Warning:

Observe the following safety precautions during server operation and maintenance:

Do not insert objects through openings in the chassis. Doing so could result in a short circuit that might cause a fire or an electrical shock.

Do not operate the server in an explosive atmosphere, in the presence of flammable gases.

To ensure proper cooling, always operate the server with its covers in place. Do not block any openings on the chassis. Do not place the server near a heater.

Always exit the software application properly before turning off the server to ensure data integrity.

24 8e6 Threat A nalysis R eporter Quick S tart Guide

Show 4 more labels / short text on this page
• · • · • · •
Page 29 of the 8e6 Technologies TAR user manual — Electrical Safety Precautions
Page 29 · click to enlarge
Page 29

Do not expose the server to rain or use near water. If liquids of any kind should leak into the chassis, power down the server, unplug it, and contact 8e6 Technologies technical support.

Disconnect power from the server before cleaning the unit. Do not use liquid or aero sol cleaners.

AC Power Cord and Cable Precautions

Warning:

The AC power cord for the server must be plugged into a grounded, power outlet.

Do not modify or use a supplied AC power cord if it is not the exact type required in the region where the server will be installed and used. Replace the cord with the cor rect type.

Route the AC power cord and cables away from moving parts and foot traffic.

Do not allow anything to rest on the AC power cord and cables.

Never use the server if the AC power cord has been damaged.

Always unplug the AC power cord before removing the unit for servicing.

Electrical Safety Precautions

Warning:

Heed the following safety precautions to protect yourself from harm and the server from damage:

To prevent damage to the server, read the information in this document for selection of the proper input voltage.

Do not wear rings or wristwatches when troubleshooting electrical circuits.

To avoid fire hazard, use only the specified fuse(s) with the correct type number, volt age, and current ratings. Only qualified service personnel should replace fuses.

Qualified service personnel should be properly grounded when servicing the unit.

Qualified service personnel should perform a safety check after any service is per formed.

8e6 Threat A nalysis R eporter Quick S tart Guide 25

Show 13 more labels / short text on this page
• · • · • · • · • · • · • · • · • · • · • · • · •
Page 30 of the 8e6 Technologies TAR user manual — Motherboard Battery Precautions
Page 30 · click to enlarge
Page 30

Motherboard Battery Precautions

Caution:

The battery on the motherboard should not be replaced without following instructions provided by the manufacturer. Only qualified service personnel should replace batteries.

The battery contains energy and, as with all batteries, a malfunction can cause heat, smoke, or fire, release toxic materials, or cause burns. Do not disassemble, puncture, drop, crush, bend, deform, submerge or modify the battery. Do not incinerate or expose to heat above 140°F (60°C).

There is a danger of explosion if the battery on the motherboard is installed upside down, which will reverse its polarities.

26 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 31 of the 8e6 Technologies TAR user manual — LCD Panel Setup Requirements (for SL and HL Units)
Page 31 · click to enlarge
Page 31

I nstall the S erver

Step 1: Initial Setup Procedures

This step requires you to link the workstation to the Threat Analysis Reporter. You have the option of using the text-based Quick Start setup procedures described in Step 1A, or, if you have an SL or HL unit, the LCD panel setup procedures described in Step 1B.

Quick Start Setup Requirements

Threat Analysis Reporter unit with AC power cord either one of two options:

PC monitor with AC power cord and keyboard, or PC laptop computer with HyperTerminal and serial port cable (and USB DB9 se rial adapter, if there is no serial port on your laptop)

Go to Step 1A to execute Quick Start Setup Procedures.

LCD Panel Setup Requirements (for SL and HL Units)

The following hardware is required for LCD panel setup procedures, if using an SL or HL unit:

Threat Analysis Reporter SL or HL with AC power cord(s) Bezel with LCD panel mounted on chassis front

Go to Step 1B to execute LCD Panel Setup Procedures.

8e6 Threat A nalysis R eporter Quick S tart Guide 27

• •

Page 32 of the 8e6 Technologies TAR user manual — Serial Console Setup
Page 32 · click to enlarge
Page 32

Step 1A: Quick Start Setup Procedures

Link the Workstation to the Threat Analysis Reporter

Monitor and Keyboard Setup

A. Connect the PC monitor and keyboard cables to the rear of the chassis (see Fig. 1

for an SL or MSA unit, and Fig. 2 for an HL unit).

B. Turn on the PC monitor.

C. Power on the Threat Analysis Reporter by dropping down the face plate and pressing

the large button at the right of the front panel (see Fig. 3 for an SL unit, Fig. 4 for an MSA unit, and Fig. 5 for an HL unit).

Once the Threat Analysis Reporter is powered up, proceed to the Quick Start menu instructions.

Serial Console Setup

A. Using the serial port cable (and USB DB9 serial adapter, if necessary), connect the

laptop to the rear of the chassis (see Fig. 1 for an SL or MSA unit, and Fig. 2 for an HL unit).

B. Power on the laptop.

C. Power on the Threat Analysis Reporter by pressing the large button on the front

panel (see Fig. 3 for an SL unit, Fig. 4 for an MSA unit, and Fig. 5 for an HL unit).

8e6 Technologies TAR — Serial Console Setup diagram (page 32)
Fig. 24 · Serial Console Setup

Fig. 1 - Portion of SL and MSA chassis rear

8e6 Technologies TAR — Serial Console Setup diagram (page 32)
Fig. 25 · Serial Console Setup

Fig. 2 - Portion of HL chassis rear

28 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 33 of the 8e6 Technologies TAR user manual — Step 1A: Quick Start Setup Procedures
Page 33 · click to enlarge
Page 33
8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 33)
Fig. 26 · Step 1A: Quick Start Setup Procedures

Fig. 3 - Diagram of SL chassis front panel, power button at far right

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 33)
Fig. 27 · Step 1A: Quick Start Setup Procedures

Fig. 4 - Diagram of MSA chassis front panel, power button at far right

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 33)
Fig. 28 · Step 1A: Quick Start Setup Procedures

Fig. 5 - Diagram of HL chassis front panel, power button at far right

Once the Threat Analysis Reporter is powered up, proceed to the instructions for Hyper Terminal Setup Procedures.

8e6 Threat A nalysis R eporter Quick S tart Guide 29

Page 34 of the 8e6 Technologies TAR user manual — HyperTerminal Setup Procedures
Page 34 · click to enlarge
Page 34

HyperTerminal Setup Procedures

If using a serial console, follow these procedures to create a HyperTerminal session on the serial console.

A. Launch HyperTerminal by going to Start > Programs > Accessories > Communica

tions > HyperTerminal:

8e6 Technologies TAR — HyperTerminal Setup Procedures diagram (page 34)
Fig. 29 · HyperTerminal Setup Procedures

B. In the Connection Description dialog box, enter any session Name, and then click

OK to open the Connect To dialog box:

8e6 Technologies TAR — HyperTerminal Setup Procedures diagram (page 34)
Fig. 30 · HyperTerminal Setup Procedures

30 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 35 of the 8e6 Technologies TAR user manual — Step 1A: Quick Start Setup Procedures
Page 35 · click to enlarge
Page 35

C. At the Connect using field, select the COM port assigned to the serial port on the

laptop (probably “COM1”), and then click OK to open the Properties dialog box, dis playing the Port Settings tab:

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 35)
Fig. 31 · Step 1A: Quick Start Setup Procedures

D. Specify the following session settings:

Bits per second9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: Hardware

E. Click OK to connect to the HyperTerminal session:

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 35)
Fig. 32 · Step 1A: Quick Start Setup Procedures

8e6 Threat A nalysis R eporter Quick S tart Guide 31

Page 36 of the 8e6 Technologies TAR user manual — Step 1A: Quick Start Setup Procedures
Page 36 · click to enlarge
Page 36

F. In the HyperTerminal session window, go to File > Properties to open the Properties

dialog box, displaying the Connect To and Settings tabs:

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 36)
Fig. 33 · Step 1A: Quick Start Setup Procedures

G. Click the Settings tab, and at the Emulation menu select “VT100”.

H. Click OK to close the dialog box, and to go to the login screen.

32 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 37 of the 8e6 Technologies TAR user manual — Login screen, password prompts
Page 37 · click to enlarge
Page 37

Quick Start menu instructions

For these Quick Start setup procedures, you will need your network administrator to pro vide you the LAN 1 and LAN 2 IP address and subnet mask, gateway IP address, DNS server IP address(es), host name of the server, and IP address for the Web interface (if using a NAT device).

Login screen, password prompts

The login screen displays after powering on the Threat Analysis Reporter unit using a monitor and keyboard, or after creating a HyperTerminal session.

A. At the login prompt, type in menu.

B. Press the Enter key to display the Password prompt.

C. At the Password prompt, type in the following: #s3tup#r3k

D. Press Enter to display the Quick Start menu screen:

8e6 Technologies TAR — Login screen, password prompts diagram (page 37)
Fig. 34 · Login screen, password prompts

8e6 Threat A nalysis R eporter Quick S tart Guide 33

Page 38 of the 8e6 Technologies TAR user manual — Step 1A: Quick Start Setup Procedures
Page 38 · click to enlarge
Page 38

E. At the Press the number of your selection prompt, press 2 to display the Adminis

trator Password Entry screen:

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 38)
Fig. 35 · Step 1A: Quick Start Setup Procedures

F. At the Enter the administrator password prompt, re-enter your password:

G. Press Enter to display the Administration menu where you can begin the Quick Start

setup process using the configuration screens:

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 38)
Fig. 36 · Step 1A: Quick Start Setup Procedures

H. At the Press the number of your selection prompt, press 2 to select the “Quick

Start setup” process. This process takes you to the Configure Network Interface screen.

34 8e6 Threat A nalysis R eporter Quick S tart Guide

#s3tup#r3k

Page 39 of the 8e6 Technologies TAR user manual — Configure Network Interface screen
Page 39 · click to enlarge
Page 39

Configure Network Interface screen

8e6 Technologies TAR — Configure Network Interface screen diagram (page 39)
Fig. 37 · Configure Network Interface screen

A. At the Enter interface lan1 IP address field, enter the IP address for the LAN 1

interface, and then press Enter to go to the next screen.

8e6 Technologies TAR — Configure Network Interface screen diagram (page 39)
Fig. 38 · Configure Network Interface screen

B. At the Enter interface lan1 netmask field, enter the subnet mask for the LAN 1 in

terface using the dotted decimals notation format. Press Enter to display the confir mation prompt.

8e6 Threat A nalysis R eporter Quick S tart Guide 35

Page 40 of the 8e6 Technologies TAR user manual — Step 1A: Quick Start Setup Procedures
Page 40 · click to enlarge
Page 40

C. Press Y for “Yes” to confirm and save your entries for the LAN1 interface, and to go

to the next screen.

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 40)
Fig. 39 · Step 1A: Quick Start Setup Procedures

D. At the Enter interface lan2 IP address field, enter the IP address for the LAN 2

interface, and then press Enter to go to the next screen.

8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 40)
Fig. 40 · Step 1A: Quick Start Setup Procedures

E. At the Enter interface lan2 netmask field, using the dotted decimals notation for

mat, enter the subnet mask for the LAN 2 interface. Press Enter to display the confir mation prompt.

F. Press Y for “Yes” to confirm and save your entries for the LAN 2 interface, and to go

to the Configure default gateway screen.

36 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 41 of the 8e6 Technologies TAR user manual — Configure Domain Name Servers screen
Page 41 · click to enlarge
Page 41

Configure default gateway screen

8e6 Technologies TAR — Configure default gateway screen diagram (page 41)
Fig. 41 · Configure default gateway screen

A. At the Enter default gateway IP field, enter the IP address for the default gateway.

Press Enter to display the confirmation prompt.

B. Press Y for “Yes” to confirm and save your entry for the gateway IP address, and to

go to the Configure Domain Name Servers screen.

Configure Domain Name Servers screen

8e6 Technologies TAR — Configure Domain Name Servers screen diagram (page 41)
Fig. 42 · Configure Domain Name Servers screen

A. At the Enter first DNS server IP field, enter the IP address for the primary Domain

Name Server. Press Enter to go to the next screen.

8e6 Threat A nalysis R eporter Quick S tart Guide 37

Page 42 of the 8e6 Technologies TAR user manual — Configure Host Name screen
Page 42 · click to enlarge
Page 42
8e6 Technologies TAR — Step 1A: Quick Start Setup Procedures diagram (page 42)
Fig. 43 · Step 1A: Quick Start Setup Procedures

B. At the Enter (optional) second DNS server IP field, if you have a secondary Do

main Name Server you wish to use, enter the IP address for that server. Press Enter to display the confirmation prompt.

C. Press Y for “Yes” to confirm and save your entries for the domain name servers, and

to go to the Configure Host Name screen.

Configure Host Name screen

8e6 Technologies TAR — Configure Host Name screen diagram (page 42)
Fig. 44 · Configure Host Name screen

A. At the Enter host name field, enter the host name of the server. Press Enter to dis

play the confirmation prompt.

38 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 43 of the 8e6 Technologies TAR user manual — Time zone regional configuration screen
Page 43 · click to enlarge
Page 43

B. Press Y for “Yes” to confirm and save your entry for the host name, and to go to the

Time zone regional configuration screen.

Time zone regional configuration screen

8e6 Technologies TAR — Time zone regional configuration screen diagram (page 43)
Fig. 45 · Time zone regional configuration screen

A. Use the up and down arrows in your keyboard to select your region. After selecting

your locality, press Y for “Yes” to confirm and save your regional selection, and to go to the next screen:

8e6 Technologies TAR — Time zone regional configuration screen diagram (page 43)
Fig. 46 · Time zone regional configuration screen

B. Use the up and down arrows in your keyboard to select your region. After selecting

your locality, press Y for “Yes” to confirm and save your regional selection, and to go to the Configure Wizard user screen.

8e6 Threat A nalysis R eporter Quick S tart Guide 39

Page 44 of the 8e6 Technologies TAR user manual — Configure Wizard user screen
Page 44 · click to enlarge
Page 44

Configure Wizard user screen

8e6 Technologies TAR — Configure Wizard user screen diagram (page 44)
Fig. 47 · Configure Wizard user screen

A. At the Enter wizard user name field, enter the username that will be used to access

the setup wizard in the Threat Analysis Reporter interface. Press Enter to display the confirmation prompt.

B. Press Y for “Yes” to confirm and save your entry and to go to the next screen.

8e6 Technologies TAR — Configure Wizard user screen diagram (page 44)
Fig. 48 · Configure Wizard user screen

C. At the Enter wizard password field, enter the password that will be used to access

the setup wizard in the Threat Analysis Reporter interface. Press Y for “Yes” to con firm and save your entry and to go to the Quick Start Setup confirmation screen.

40 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 45 of the 8e6 Technologies TAR user manual — Administration menu
Page 45 · click to enlarge
Page 45

Quick Start Setup confirmation screen

8e6 Technologies TAR — Quick Start Setup confirmation screen diagram (page 45)
Fig. 49 · Quick Start Setup confirmation screen

Press Y for “Yes” to save all your Quick Start setup entries and to return to the Adminis tration menu.

Administration menu

After making all entries using the Quick Start setup process, you will return to the Admin istration menu. Press X to return to the Quick Start menu screen. Or, to verify the status of the Threat Analysis Reporter and review the entries you made using the Quick Start setup process, press 1 to view the System Status screen.

8e6 Threat A nalysis R eporter Quick S tart Guide 41

Page 46 of the 8e6 Technologies TAR user manual — Log Off, Disconnect the Peripherals
Page 46 · click to enlarge
Page 46

System Status screen

8e6 Technologies TAR — System Status screen diagram (page 46)
Fig. 50 · System Status screen

The System Status screen contains the following information:

lan1 interface for web access and R3000 communications: LAN1 IP address and netmask specified in screen 3 (Configure Network Interface), and current status (“Active” or “Inactive”) lan2 interface for bandwidth monitoring: LAN2 IP address and netmask specified in screen 4 (Configure Network Interface), and current status (“Active” or “Inactive”) Default gateway IP address specified in screen 5 (Configure default gateway) Configure host name specified in screen 7 (Configure Host Name) DNS server IP address(es) specified in screen 6 (Configure Domain Name Servers) Current status of the Threat Analysis Reporter Current Version of the Threat Analysis Reporter software

• • • • •

Log Off, Disconnect the Peripherals

A. After completing the Quick Start setup procedures, return to the Quick Start menu

screen and press 9 to log out.

B. Disconnect the peripherals from the Threat Analysis Reporter.

C. Proceed to Physically Connect the Unit to the Network.

42 8e6 Threat A nalysis R eporter Quick S tart Guide

• · •

Page 47 of the 8e6 Technologies TAR user manual — Bandwidth Management
Page 47 · click to enlarge
Page 47

Physically Connect the Unit to the Network

After performing initial setup procedures for the Threat Analysis Reporter, the unit should be physically connected to the network. This step requires a standard CAT-5E cable to connect the unit to the network. An additional CAT-5E cable is required if the Ethernet Tap unit will be installed for bandwidth monitoring.

A. Plug one end of a standard CAT-5E cable into the Threat Analysis Reporter’s LAN 1

port, the port on the left.

Fig. 1 - Portion of SL and MSA chassis rear

Fig. 2 - Portion of HL chassis rear

B. Plug the other end of the CAT-5E cable into an open port on the network switch.

Bandwidth Management

If you choose to install the Ethernet Tap for bandwidth monitoring, you will need to con nect it to the Threat Analysis Reporter at this point. Refer to Appendix A at the end of this document for instructions on how to connect the Ethernet Tap unit.

8e6 Threat A nalysis R eporter Quick S tart Guide 43

Page 48 of the 8e6 Technologies TAR user manual — 8e6 menu
Page 48 · click to enlarge
Page 48

Step 1B: LCD Panel Setup Procedures

On an SL or HL unit, the Threat Analysis Reporter can be configured using the LCD panel on front of the chassis bezel. When the bezel is placed on the front of the chassis, with the USB plug inserted into the USB port, the default LCD screen displays with the following message:

To the right of the LCD screen, the keypad displays, consisting of the following keys: up arrow, down arrow, left arrow, right arrow, checkmark, and “X”.

LCD Menu

Press the “X” key to display the LCD Menu:

8e6 Technologies TAR — LCD Menu diagram (page 48)
Fig. 51 · LCD Menu

In the LCD panel, an arrow displays to the left of the currently selected menu item. Use the up or down arrow keys to navigate the menu. After making your menu selection, press the checkmark key to accept your selection.

8e6 menu

When “8e6 >” is selected, the following menu items display on the screen:

Current Patch Level IP / LAN1 > IP / LAN2 > Gateway DNS 1 > DNS 2 > Host Name > Regional Setting (Time Zone, date, time) Admin Console Wizard User

44 8e6 Threat A nalysis R eporter Quick S tart Guide

8e6 Technologies · Display Initializing · Please Wait

Page 49 of the 8e6 Technologies TAR user manual — IP / LAN1 and LAN2
Page 49 · click to enlarge
Page 49

Reboot > Shutdown >

  • NOTE: Navigation tips in the 8e6 menu:
  • Use the up / down arrow key to scroll up / down the menu
  • Press the checkmark key to choose the current selection
  • Press the “X” to go back to the previous screen

Make a selection from the menu, and press the checkmark key to go to that screen.

Current Patch Level

When the Current Patch Level option is selected, “Threat Analysis Reporter” and the ver sion number of the currently installed build displays.

IP / LAN1 and LAN2

When the IP / LAN 1 (LAN 2) option is selected, the IP / LAN 1 (LAN 2) screen displays with the following menu items:

Configure LAN 1 (2) IP Change LAN1 (2) Netmask

A. Choose Configure LAN 1 (2) IP and press the checkmark key to go to the Configure

LAN 1 (2) IP screen.

B. Use the up / down keys to increase / decrease the current value, and the left / right

arrow keys to navigate across the line.

C. Press the checkmark key to accept your entry and to return to the previous screen.

D. Choose Change LAN1 (2) Netmask and press the checkmark key to go to the

Change LAN1 (2) Netmask screen.

E. Use the up / down keys to increase / decrease the current value, and the left / right

arrow keys to navigate across the line.

F. Press the checkmark key to accept your entry and to return to the previous screen.

G. Press the “X” key to return to the 8e6 menu.

8e6 Threat A nalysis R eporter Quick S tart Guide 45

Page 50 of the 8e6 Technologies TAR user manual — Host Name
Page 50 · click to enlarge
Page 50

Gateway

When the Gateway option is selected, the Gateway screen displays with the Configure Gateway IP menu item.

A. Choose Configure Gateway IP and press the checkmark key to go to the Configure

Gateway IP screen.

B. Use the up / down keys to increase / decrease the current value, and the left / right

arrow keys to navigate across the line.

C. Press the checkmark key to accept your entry and to return to the previous screen.

D. Press the “X” key to return to the 8e6 menu.

DNS 1 and 2

When the DNS 1 (2) option is selected, the DNS 1 (2) screen displays with the Configure DNS IP 1 (2) menu item.

A. Choose Configure DNS IP 1 (2) and press the checkmark key to go to the Configure

DNS IP 1 (2) screen.

B. Use the up / down keys to increase / decrease the current value, and the left / right

arrow keys to navigate across the line.

C. Press the checkmark key to accept your entry and to return to the previous screen.

D. Press the “X” key to return to the 8e6 menu.

Host Name

When the Host Name option is selected, the Host Name screen displays with the Config ure Hostname menu item.

A. Choose Configure Hostname and press the checkmark key to go to the Configure

Hostname screen.

B. Use the arrow keys to navigate the menu. Press the right arrow key to view the

alphabets in first uppercase and then lowercase, numbers from 0-9, and lastly the symbol characters.

  • If the down arrow key is pressed first—instead of the right arrow key—the symbol characters display first.
  • Press the “X” key to remove a character and move the cursor to the first posi tion in the line.

46 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 51 of the 8e6 Technologies TAR user manual — Reboot
Page 51 · click to enlarge
Page 51

C. Press the checkmark key to return to the previous screen.

D. Press the “X” key to return to the 8e6 menu.

Regional Setting (Time Zone, date, time)

When the Regional Setting (Time Zone, date, time) option is selected, the Regional Set ting (Time Zone, date, time) screen displays with the Region menu item.

A. Choose Region, and use the left / right arrow keys to view the available region se

lections.

B. After making a selection, press the checkmark key to display the Choose a Location

screen.

C. Choose Location, and use the left / right arrow keys to view the available location

selections.

D. After making a selection, press the checkmark key to display the Save Changes?

screen:

Choose Yes to save your changes and to return to the 8e6 menu. Choose No to return to the previous screen.

Admin Console Wizard User

When the Admin Console Wizard User option is selected, the Admin Console Wizard User screen displays with two menu selections:

Choose Reset TAR setup wizard username to reset the username and to return to the 8e6 menu.

Choose Reset TAR setup wizard password to reset the password and to return to the 8e6 menu.

Reboot

When the Reboot option is selected, the Reboot screen displays with two menu items.

A. Choose one of two options:

Yes, reboot now!!! - This selection reboots the Threat Analysis Reporter. No, cancel reboot - This selection returns you to the previous screen.

B. Press the “X” key to return to the 8e6 menu.

8e6 Threat A nalysis R eporter Quick S tart Guide 47

Show 4 more labels / short text on this page
• • · • · • · • •
Page 52 of the 8e6 Technologies TAR user manual — Backlight
Page 52 · click to enlarge
Page 52

Shutdown

When the Shutdown option is selected, the Shutdown screen displays with two menu items.

A. Choose one of two options:

Yes, shutdown now!! - This selection shuts down the Threat Analysis Reporter. No, cancel shutdown - This selection returns you to the previous screen.

B. Press the “X” key to return to the 8e6 menu.

LCD Options menu

When “LCD Options >” is selected, the following menu items display on the screen:

Heartbeat Backlight LCD Controls >

Make a selection from the menu, and press the checkmark key to go to that screen.

Heartbeat

When the Heartbeat option is selected, the Heartbeat screen displays.

A. Press the checkmark or right arrow key three times to view each of the three avail

able options:

heartbeat feature enabled (checkbox populated with “x”) heartbeat feature disabled (checkbox empty) check for a heartbeat now (checkbox populated with checkmark, and blinking heartbeat symbol displayed in the line above)

B. After making your selection, press the “X” key to return to the previous screen.

Backlight

When the Backlight option is selected, the Backlight screen displays.

A. Press the checkmark or right arrow key three times to view each of the three avail

able options:

backlight feature enabled (checkbox populated with “x” and backlight turns on) backlight feature disabled (checkbox empty and backlight turns off) display the backlight now (checkbox populated with checkmark, and backlight turns on)

B. After making your selection, press the “X” key to return to the previous screen.

48 8e6 Threat A nalysis R eporter Quick S tart Guide

Show 4 more labels / short text on this page
• • · • • • · • • • · • • •
Page 53 of the 8e6 Technologies TAR user manual — Bandwidth Management
Page 53 · click to enlarge
Page 53

LCD Controls

When the LCD Controls option is selected, the LCD Controls screen displays with the following menu items: Contrast, On Brightness, Off Brightness.

A. Choose one of the menu selections and press the checkmark key to go to that

screen:

Contrast - In the Contrast screen, use the left / right arrow keys to decrease / increase the text and screen contrast. On Brightness - In the On Brightness screen, use the left / right arrow keys to decrease / increase the brightness of a screen with a feature that is enabled. Off Brightness - In the Off Brightness screen, use the left / right arrow keys to decrease / increase the brightness of a screen with a feature that is disabled. B. After making your selection, press the “X” key to return to the previous screen.

Bandwidth Management

If you choose to install the Ethernet Tap for bandwidth monitoring, you will need to con nect it to the Threat Analysis Reporter at this point. Refer to Appendix A at the end of this document for instructions on how to connect the Ethernet Tap unit.

8e6 Threat A nalysis R eporter Quick S tart Guide 49

• · • · •

Page 54 of the 8e6 Technologies TAR user manual — Access the Threat Analysis Reporter Administrator Console
Page 54 · click to enlarge
Page 54

Step 2: Wizard Setup Procedures

For this step, you will need your network administrator to provide you the following infor mation:

IP range and netmask of machines on the network the Threat Analysis Reporter server will be monitoring R3000 IP address, and port number to be used between the R3000 and Threat Analysis Reporter 8e6 Enterprise Reporter server IP address and server name, if an ER unit is con nected to the R3000

Access the Threat Analysis Reporter Administrator Console

A. Launch Internet Explorer.

B. In the address field, type in http://x.x.x.x:8080/8e6tar/wizard.html (in which “x.x.x.x”

represents the eth0 (LAN1) IP address entered in the Connect Network Interface screen of the Quick Start Setup Procedures). In our example, this entry would be: http://200.100.10.10:8080/8e6tar/wizard.html.

C. Click Go to open the Threat Analysis Reporter interface and the EULA Agreement

dialog box:

8e6 Technologies TAR — Access the Threat Analysis Reporter Administrator Console diagram (page 54)
Fig. 52 · Access the Threat Analysis Reporter Administrator Co…

50 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 55 of the 8e6 Technologies TAR user manual — Log in to the Threat Analysis Reporter Wizard
Page 55 · click to enlarge
Page 55

D. After reading the End User License Agreement, you have the option to do either of

the following:

Click No to close both the EULA Agreement dialog box and the Threat Analysis Reporter interface. You will not be able to enable the Threat Analysis Reporter for use in your environment.

Click Yes to close the EULA Agreement dialog box and to open the Login dialog box:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 55)
Fig. 53 · Step 2: Wizard Setup Procedures

Proceed to the next sub-section: Log in to the Threat Analysis Reporter Wizard.

Log in to the Threat Analysis Reporter Wizard

A. In the Username field of the Login dialog box, type in the username specified in the

Configure Wizard user screen of the Quick Start Setup Procedures. In our example, this entry would be: taruser.

B. In the Password field, type in the password specified in the Configure Wizard user

screen of the Quick Start Setup Procedures.

C. Click LOGIN to close the login dialog box and to go to Step 1 of wizard setup proce

dures in the Threat Analysis Reporter Wizard (see Wizard Step 1: Register adminis trator).

8e6 Threat A nalysis R eporter Quick S tart Guide 51

• · •

Page 56 of the 8e6 Technologies TAR user manual — Wizard Step 1: Register administrator
Page 56 · click to enlarge
Page 56

Wizard Step 1: Register administrator

Step 1 is performed in the left side of the first screen of the wizard:

8e6 Technologies TAR — Wizard Step 1: Register administrator diagram (page 56)
Fig. 54 · Wizard Step 1: Register administrator

A. Enter the username the global administrator will use when logging into the Threat

Analysis Reporter Administrator console. The global administrator has the highest level of permissions in the Threat Analysis Reporter interface.

B. Enter the password to be used with that username, and enter the same password

again in the confirm password field.

C. Enter the email address of the global administrator, who will be notified via email

regarding system alerts.

52 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 57 of the 8e6 Technologies TAR user manual — Step 2: Wizard Setup Procedures
Page 57 · click to enlarge
Page 57

D. Click the [+] Add tab below to open the IP Range Information dialog box:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 57)
Fig. 55 · Step 2: Wizard Setup Procedures

E. Enter the Bandwidth IP address range for the bandwidth the Threat Analysis Re

porter will monitor.

F. Enter the Bandwidth Netmask for the bandwidth IP range to be monitored, using

the dotted decimals notation format.

G. Click OK to close the dialog box and to display your entries in the list box:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 57)
Fig. 56 · Step 2: Wizard Setup Procedures

8e6 Threat A nalysis R eporter Quick S tart Guide 53

Page 58 of the 8e6 Technologies TAR user manual — Step 2: Wizard Setup Procedures
Page 58 · click to enlarge
Page 58

To modify an IP address range, double-click the entry in the list box to highlight it and to display the [-] Remove tab to the left of the [+] Add tab:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 58)
Fig. 57 · Step 2: Wizard Setup Procedures

To modify the entries made for the IP address range, click the [+] Add tab to re- open the IP Range Information dialog box and edit information, as necessary. Click OK to close the dialog box and to display the modified information in the list box.

To remove the entry for the IP address range from the list box, click the [-] Re move tab. Click the [+] Add tab to open the IP Range Information dialog box and make new entries for the IP address range.

54 8e6 Threat A nalysis R eporter Quick S tart Guide

• · •

Page 59 of the 8e6 Technologies TAR user manual — R3000:
Page 59 · click to enlarge
Page 59

Wizard Step 2: Register R3000 & ER

Step 2 is performed in the right side of the first screen of the wizard.

R3000:

Specify information for the R3000 to be used with the Threat Analysis Reporter:

A. Click the [+] Add tab above the R3000 list box to open the R3000 Information dialog

box:

8e6 Technologies TAR — R3000: diagram (page 59)
Fig. 58

B. Enter the IP address of the R3000 server to be used with the Threat Analysis Re

porter. In our example, this is: 200.100.160.74, which is the LAN 2 IP address of the R3000 server.

C. Enter the Server Name of the R3000 to be used with the Threat Analysis Reporter,

which is any name you wish to associate with that R3000. In our example, this is: R3000LOGO.

D. Respond to the question “Is this your Source R3000?” by clicking the “Yes” check

box, if this R3000 will be designated the primary R3000 to be associated with the Threat Analysis Reporter. Otherwise, leave the checkbox blank.

8e6 Threat A nalysis R eporter Quick S tart Guide 55

Page 60 of the 8e6 Technologies TAR user manual — Step 2: Wizard Setup Procedures
Page 60 · click to enlarge
Page 60

E. Click OK to close the dialog box and to display your entries in the list box:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 60)
Fig. 59 · Step 2: Wizard Setup Procedures

To modify an R3000 entry, double-click the R3000 entry in the list box to highlight it and to display the Set as Source tab and the [-] Remove tab to the left of the [+] Add tab:

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 60)
Fig. 60 · Step 2: Wizard Setup Procedures

56 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 61 of the 8e6 Technologies TAR user manual — Step 2: Wizard Setup Procedures
Page 61 · click to enlarge
Page 61

To modify the IP address and Server Name for the R3000 server, click the [+] Add tab to re-open the R3000 Information dialog box, and edit information as necessary. Click OK to close the dialog box and to display the modified informa tion in the list box.

To designate an R3000 as the Source R3000 server, click the entry for the R3000 server in the list box to highlight it, and then click the Set as Source tab to display “Source” in the Source column for that entry in the list box.

To remove the entry for the R3000 server from the list box, click the [-] Remove tab.

8e6 Technologies TAR — Step 2: Wizard Setup Procedures diagram (page 61)
Fig. 61 · Step 2: Wizard Setup Procedures

8e6 Threat A nalysis R eporter Quick S tart Guide 57

Page 62 of the 8e6 Technologies TAR user manual — ER:
Page 62 · click to enlarge
Page 62

ER:

Respond to the question “Do you have an Enterprise Reporter?” by clicking the radio button corresponding to either “Yes” or “No”.

If “No” was selected, click SAVE > at the bottom right of the screen to go to Step 3.

If “Yes” was selected, the IP address and Server Name fields display in place of the radio buttons. The < Back button displays above the Server Name field.

8e6 Technologies TAR — ER: diagram (page 62)
Fig. 62

A. Enter the IP address of the ER server to be used with the Threat Analysis Re

porter. In our example, this is: 200.10.101.76.

B. Enter the Server Name of the ER server to be used with the Threat Analysis

Reporter. In our example, this is: er4logo.

C. Click SAVE > at the bottom right of the screen to save all settings entered during

the wizard process, and to go to Step 3.

58 8e6 Threat A nalysis R eporter Quick S tart Guide

• · •

Page 63 of the 8e6 Technologies TAR user manual — C onclusion
Page 63 · click to enlarge
Page 63

Step 3: Server Settings

Step 3, the following R3000 server information displays: SMTP Server Settings, Patch Server Settings, PROXY Server Settings, NTP Server Settings:

8e6 Technologies TAR — Step 3: Server Settings diagram (page 63)
Fig. 63 · Step 3: Server Settings

After reviewing the information in this screen, the following actions can now be per formed:

To print this information, click the PRINT button.

Click LOGIN to close the wizard and to open the login dialog box of the Threat Analy sis Reporter interface so you can begin using the application.

C onclusion

Congratulations; you have completed the Threat Analysis Reporter quick start proce dures. Now that the Threat Analysis Reporter is running on your network, the next step is to set up user groups or administrator groups. You will set up and configure gauges thereafter.

Obtain the latest Threat Analysis Reporter User Guide from our Web site at http:// www.8e6.com/docs/tar_ug.pdf.

8e6 Threat A nalysis R eporter Quick S tart Guide 59

• · •

Page 64 of the 8e6 Technologies TAR user manual — LED Indicator Color Condition Description
Page 64 · click to enlarge
Page 64

LED I ndicators and B uttons

SL and MSA Units

Front LED Indicators and Buttons for Hardware Status Monitoring

LED indicators and buttons for hardware status monitoring display on the front panel, located on the right side of the SL and MSA chassis (see diagrams below).

8e6 Technologies TAR — Front LED Indicators and Buttons for Hardware Status Monitoring diagram (page 64)
Fig. 64 · Front LED Indicators and Buttons for Hardware Status…

LED Indicator Key

HD = HDD Activity

NIC1 = LAN 1

NIC2 = LAN 2

SL chassis control panel

8e6 Technologies TAR — NIC1 = LAN 1 diagram (page 64)
Fig. 65

LED Indicator Key Button Key

A = Power F = Reset

B = HDD Activity G = Power

C = LAN 1

D = LAN 2

MSA chassis control panel

LED indicators alert you to the status of a feature on the unit while buttons let you per form a function on the unit.

LED Indicator Color Condition Description

Power Green On System On

HDD Amber Blinking HDD Activity

Off No HDD Activity

LAN 1 & LAN 2 Green On Link Connected

Overheat Red On System Overheated

60 8e6 Threat A nalysis R eporter Quick S tart Guide

Show 7 more labels / short text on this page
PWR = Power · OH = Overheat · E = Overheat · Off System Off · Blinking LAN Activity · Off Disconnected · Off System Normal
Page 65 of the 8e6 Technologies TAR user manual — NIC1 = LAN 1
Page 65 · click to enlarge
Page 65

HL Unit

Front LED Indicators and Buttons for Hardware Status Monitoring

On an HL unit, the following control panel buttons, icons, and LED indicators for hard ware status monitoring display on the right side of the front panel:

8e6 Technologies TAR — Front LED Indicators and Buttons for Hardware Status Monitoring diagram (page 65)
Fig. 66 · Front LED Indicators and Buttons for Hardware Status…

LED Indicator Key

HD = HDD Activity

NIC1 = LAN 1

NIC2 = LAN 2

HL chassis control panel

UID = Unique IDentifier

The buttons and LED indicators for the depicted icons function as follows:

UID (button) – On an HL unit, when the UID button is pressed, a steady blue LED displays on both the front and rear of the chassis (see also Rear of Chassis). These indicators are used for easy location of the chassis in a large stack configuration. The LED remains on until the button is pressed a second time.

Overheat/Fan Fail (icon) – This LED is unlit unless the chassis is overheated. A flashing red LED indicates a fan failure. A steady red LED (on and not flashing) indicates an overheating condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm.

NIC2 (icon) – A flashing green LED indicates network activity on LAN2.

NIC1 (icon) – A flashing green LED indicates network activity on LAN1.

HDD (icon) – In addition to displaying in the control panel, this icon also displays on the front panel on each hard drive carrier. A green LED indicates hard drive activity. An unlit LED on a drive carrier may indicate a hard drive failure.

Power (icon) – The LED is unlit when the server is turned off. A steady green LED indicates power is being supplied to the unit’s power supplies. (See also Rear of Chassis.) A steady amber LED—or an unlit LED—may indicate a disconnected or loose power supply cord.

Power (button) – When the power button is pressed, the main power to the server is turned on. When the power button is pressed again, the main power to the server is removed but standby power is still supplied to the server.

8e6 Threat A nalysis R eporter Quick S tart Guide 61

PWR = Power · OH = Overheat

Page 66 of the 8e6 Technologies TAR user manual — Rear LED Indicators for Hardware Status Monitoring
Page 66 · click to enlarge
Page 66

Rear LED Indicators for Hardware Status Monitoring

UID (LED indicator) – On the rear of the HL chassis, to the left of the power supplies, a steady blue UID LED indicator displays when the UID button on the control panel is pressed. This LED remains lit until the UID button is pressed again.

8e6 Technologies TAR — Rear LED Indicators for Hardware Status Monitoring diagram (page 66)
Fig. 67 · Rear LED Indicators for Hardware Status Monitoring

Power Supplies (LED indicators) – The power supplies are located at the right on the rear of the chassis. An LED indicator is located above each of the power plugs.

8e6 Technologies TAR — Rear LED Indicators for Hardware Status Monitoring diagram (page 66)
Fig. 68 · Rear LED Indicators for Hardware Status Monitoring

62 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 67 of the 8e6 Technologies TAR user manual — LED Indicator Color Condition Description
Page 67 · click to enlarge
Page 67

HL and SL Units

Front LED Indicators for Software and Hardware Status Monitoring

On an HL or SL unit, the following LED indicators for software and hardware status moni toring display on the left side of the front panel:

8e6 Technologies TAR — Front LED Indicators for Software and Hardware Status Monitoring diagram (page 67)
Fig. 69 · Front LED Indicators for Software and Hardware Statu…

LED Indicator Key

LOG = Log Download Status

RAID = Hard Drive Status

DB = Database Status

UPDT = Software Update Status

left side of the

LED Indicator Color Condition Description

LOG Green On Downloading a log

Off No log download detected

RAID Green On RAID mode enabled and running

Off RAID mode is inactive

Red On Hard drive fault or failure

DB Green On Database is active

Red On Database in inactive

UPDT Amber On Software update detected

Off No software update detected

8e6 Threat A nalysis R eporter Quick S tart Guide 63

front panel

Page 68 of the 8e6 Technologies TAR user manual — FCC Declaration of Conformity
Page 68 · click to enlarge
Page 68

R egulatory S pecifications and D isclaimers

Declaration of the Manufacturer or Importer

Safety Compliance

USAUL 60950-1 2nd ed. 2007
EuropeLow Voltage Directive (LVD) 2006/95/EC to CB Scheme EN 60950: 2006
InternationalUL/CB to IEC 60950-1:2006

Electromagnetic Compatibility (EMC)

USAFCC CFR 47 Part 15, Verified Class A Limit
CanadaIC ICES-003 Class A Limit
EuropeEMC Directive, 2004/108/EC & Low Voltage Directive (LVD) 2006/95/EC
TaiwanBureau of Standards and Metrology Inspection (BSMI) CNS 13438: 2006

Federal Communications Commission (FCC) Class A Notice (USA)

This equipment has been tested and found to comply with the limits for a Class A digi tal device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

FCC Declaration of Conformity

Models: HL-005-004, SL-004-004, MSA-004-004

64 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 69 of the 8e6 Technologies TAR user manual — Bureau of Standards Metrology and Inspection (BSMI) - Taiwan
Page 69 · click to enlarge
Page 69

Electromagnetic Compatibility Class A Notice

Industry Canada Equipment Standard for Digital Equipment (ICES-003)

8e6 Technologies TAR — Electromagnetic Compatibility Class A Notice diagram (page 69)
Fig. 70 · Electromagnetic Compatibility Class A Notice

Bureau of Standards Metrology and Inspection (BSMI) - Taiwan

8e6 Technologies TAR — Bureau of Standards Metrology and Inspection (BSMI) - Taiwan diagram (page 69)
Fig. 71 · Bureau of Standards Metrology and Inspection (BSMI)…

8e6 Threat A nalysis R eporter Quick S tart Guide 65

Page 70 of the 8e6 Technologies TAR user manual — EMC • EN55022: 2006
Page 70 · click to enlarge
Page 70

EC Declaration of Conformity

European Community Directives Requirement (CE)

Declaration of Conformity

Manufacturer’s Name8e6 Technologies
Manufacturer’s Address828 W. Taft Avenue
Application of Council Directive(s)Low Voltage • 2006/95/EC

EMC • 2004/108/EC

Standard(s)Safety • EN60950: 2006

EMC • EN55022: 2006

  • EN55024: 1998 +A2:2003
  • EN61000-3-2: 2000
  • EN61000-3-3: 2001
Product Name(s)Internet Appliance
Product Model Number(s)HL-005-004, SL-004-004, MSA-004-004

Year in which conformity is declared: 2008

All hardware components supplied in this unit’s shipping carton are certified by our vendors to be RoHS compliant.

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

8e6 Technologies TAR — EMC • EN55022: 2006 diagram (page 70)
Fig. 72
LocationOrange, CA, USA Signature:
DateJanuary 21, 2008 Full Name: Gregory P. Smith
PositionDirector of Engineering Operations

66 8e6 Threat A nalysis R eporter Quick S tart Guide

Orange, CA 92865

Page 71 of the 8e6 Technologies TAR user manual — Other Required Installation Items
Page 71 · click to enlarge
Page 71

Tap Installation

A ppendix : O ptional E thernet T ap I nstallation

This appendix pertains to the optional installation of the Ethernet Tap unit for bandwidth monitoring.

Preliminary Setup Procedures

Unpack the Ethernet Tap Unit from the Box

Open the NetOptics Ethernet Tap box and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Technologies.

The NetOptics box should contain the following items:

1 NetOptics 10/100BaseT Tap 2 Power Supply units 2 AC Power cords 2 Crossover cables 2 Straight through cables 1 Installation Guide

Other Required Installation Items

In addition to the contents of the NetOptics box, you will need the following item to install the Ethernet Tap unit:

1 Standard CAT-5E cable

Inspect the box for damage. If the contents appear damaged, file a damage claim with the carrier immediately.

8e6 Threat A nalysis R eporter Quick S tart Guide 67

•

Page 72 of the 8e6 Technologies TAR user manual — Install the Ethernet Tap Unit
Page 72 · click to enlarge
Page 72

Tap Installation

Install the Ethernet Tap Unit

8e6 Technologies TAR — Install the Ethernet Tap Unit diagram (page 72)
Fig. 73 · Install the Ethernet Tap Unit

Diagram showing TAR Ethernet Tap installation on the network

This step is a continuation from Physically Connect the Unit to the Network in Step 1A or following setup in Step 1B. The procedures outlined in this step require the use of a CAT-5E cable.

A. Provide power to the Ethernet Tap by connecting both power cords from the unit to

the power source.

8e6 Technologies TAR — Install the Ethernet Tap Unit diagram (page 72)
Fig. 74 · Install the Ethernet Tap Unit

AC power in rear panel of NetOptics 10/100BaseT Tap

B. If a designated source R3000 (to be used with the Threat Analysis Reporter) is al

ready installed on the network, disconnect the cable that connects this R3000 to the switch.

If the designated R3000 has not yet been installed, disregard this sub-step and pro ceed to sub-step C.

68 8e6 Threat A nalysis R eporter Quick S tart Guide

Page 73 of the 8e6 Technologies TAR user manual — Install the Ethernet Tap Unit
Page 73 · click to enlarge
Page 73

Tap Installation

C. Using a crossover cable, connect one end to the Switch’s port configured to be the

destination port of the Port Mirror.

If adding a Threat Analysis Reporter to an existing installation, this port would be the port that was originally occupied by the listening interface of the R3000.

D. Connect the other end of the crossover cable to the Ethernet Tap’s Network A port.

8e6 Technologies TAR — Install the Ethernet Tap Unit diagram (page 73)
Fig. 75 · Install the Ethernet Tap Unit

Ports in front panel of NetOptics 10/100BaseT Tap

E. Using a straight through cable, connect one end to the Ethernet Tap’s Network B

port.

F. Connect the other end of the straight through cable to the R3000’s listening interface.

G. Using the second straight through cable, connect one end to the Ethernet Tap’s

Monitor A port.

H. Connect the other end of the second straight through cable to the Threat Analysis

Reporter’s listening interface.

Proceed to Step 2: Wizard Setup Procedures of the Threat Analysis Reporter installation instructions.

8e6 Threat A nalysis R eporter Quick S tart Guide 69

Page 76 of the 8e6 Technologies TAR user manual — Index
Page 76 · click to enlarge
Page 76
  • 8e6 Corporate Headquarters (USA): 828 West Taft Avenue Orange, CA 92865-4232
  • Tel: 714.282.6111 or 888.786.7999 Fax: 714.282.6116 (Sales/Technical Support)
  • 714.282.6117 (General Office)

Satellite Office: 8e6 Taiwan: 7 Fl., No. 1, Sec. 2, Ren-Ai Rd., Taipei 10055, Taiwan, R.O.C. Tel: 886-2-2397-0300 • Fax: 886-2-2397-0306

Ask about the 8e6 Technologies TAR

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the 8e6 Technologies TAR

Be the first to ask — other owners or our team will answer.