INSTRUCTION MANUAL MANUEL D’INSTRUCTIONS MANUAL DE INSTRUCCIONES


Declaration of Conformity
CAUTION
Model Number : MPX-CD163/ MPX-CD93 Trade Name : SANYO Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 Telephone No. : (818) 998-7322 • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
DO NOT OPEN
and (2) this device must accept any interference
received, including interference that may cause undesired operation.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
This class B digital apparatus complies with Canadian ICES-003.
This unit is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre.





ACCESSORIES
Fixer Power cord tie x1
– Program recording lets images from a specified camera
be recorded during four different daily time zones. – Automatic switching of camera images selected by timer
period – Setting of automatic screen switching speed for each
Power cord x1

Front



L Setting buttons (+, –)
Press this button to play back recorded images. The indicator will illuminate and the video playback images will appear on the monitor.
(SEQUENCE) This button is used to automatically change the camera image appearing in the single-screen, 4-screen or quarter screen (plus screen) display. When the SEQUENCE button is pressed, the indicator flashes and the screen changes automatically. The camera indicator also changes to match the images on the screen.
If this button is pressed while monitoring is being carried out using the single-screen display, the indicator will flash and the image will be paused. If the button is pressed once more, the image returns to normal.
N Menu reset/Clock adjust button (MENU RESET)
If monitoring is being carried out using the single-screen display, the image can be enlarged by 2x. When this button is pressed, the indicator will flash and the 2x zoom screen will be displayed.
If this button is pressed while a menu screen (setting screen) is displayed, the settings in the currently-displayed menu screen are reset to their default values. If this button is pressed while monitoring camera images, the clock is adjusted and the minutes and seconds are reset to 00.
This button is used to display the menu screen.

Rear

IN 1 2 3 4 5 6 7 9 8
4 5 6 7 9 10 11 12 13 14 15 16 8
1 2 3 4 5 6 7 8 9 10
3 4 SPOT MONITOR MAIN MONITOR MAIN MONITOR IN IN OUT
SENSOR ALARM OUT RS485 DIGITAL SPOT MONITOR MAIN MONITOR MAIN MONITOR

CONNECTIONS Turn off the power for all components before connecting them.
Be sure to carefully read the Instruction Manual for all equipment being connected to the multiplexer. If the connections are incorrect, smoke or operating malfunctions may result.
Nine cameras can be connected to the MPX-CD93 model.

Switch output connector Time lapse VCR (sold separately)


Digital connections
Up to four of these units can be connected for monitoring. By connecting several units, up to 64 cameras can be viewed with one main monitor. Also, by connecting a recorder to each multiplexer, playback of recorded images can be viewed on the main monitor. * For the MPX-CD93 model, the total number of cameras that can be viewed with one monitor is 36, nine to each unit. Use straight-type CAT-5 RS485 cables (sold separately) to connect the DIGITAL IN connectors to the digital output connectors of other devices. Use cables with a length of 3 m or less.


This unit and a digital video recorder can be connected digitally to provide high-resolution playback of recorded images. Use straight-type CAT-5 RS485 cables (sold separately) to connect the DIGITAL IN connectors to the digital output connectors of other devices. Use cables with a length of 3 m or less.

Digital video recorder (sold separately)

System control connections
Use the RS485 connector or the CONTROL connector to connect a system controller to the multiplexer. After connecting the system controller, you will need to carry out the settings that are given in the CONTROL SET menu. (See page 72.)
A When using the RS485 (RJ-11) connector Connect modular cables (sold separately) to the RS485 control connectors at the rear of the multiplexer.
To other connector A
To other connector A
Straight-type cable Cross-type cable
Straight type Cross type
B When using the CONTROL connector (A/B) Connect a twisted-pair cable (sold separately) to the A, B and C (ground) terminals of the CONTROL connector at the rear of the multiplexer. Connect signal A to signal A and signal B to signal B.
Push the cable in.
Ground To signal A
When connecting the multiplexer to a computer (sold separately), use a D-Sub 9-pin cable (sold separately) to connect the RS-232C connector to the computer. After connecting, you will need to carry out the settings that are given in the CONTROL SET menu. (See page 72.)

Twisted-pair cable · To signal B · Computer

External alarm sensor setup
Using as a monitor board during a motion sensor alarm
In order to make an external alarm sensor operate, an external switch must be connected to an ALARM IN connector. When an intruder activates the external switch (such as by opening a door), an alarm signal is received and an alarm can be made to sound. The MPX-CD93 model uses the connectors marked *.
When the motion sensor built into the multiplexer responds to an alarm, it outputs an alarm signal to the SENSOR ALARM OUT connector. If a switching circuit such as a warning lamp is connected to this connector, the warning lamp will illuminate when there is a response from the motion sensor. If the warning lamp is fixed somewhere in the layout diagram for an area such as a factory, the location of the camera can be ascertained in an instant during an emergency. The connector is always open. The pin corresponding to the number of the camera that generates a sensor response switches to Low.

1K 25mA 25V 40mW
Rated values for each connector (at 25˚C)
If a remote control circuit is constructed as shown in the illustration and connected to the remote control input (R1 and R2) terminals of the CONTROL connector, the multiplexer can be operated by remote control. (Contact LOW input) The MPX-CD93 model can control up to nine cameras.

The remote control cable should be no more than 5 m long. Note:

Following is a summary of the operations that can be carried out while monitoring camera images. Refer to the corresponding page numbers for more detailed explanations.
Viewing recorded images (See page 23.)
The following operations can be carried out while monitoring camera images and when playing back images that have been recorded.
STILL
N Viewing multiple-screen images (See page 18.)
For the MPX-CD93 model, a 9-screen display will appear. N Viewing automatically switching images (See page 20.)
Zoom · Single-screen · Still image

Alarm function
Suspicious people can be detected while monitoring by using the alarm setting function. (See page 60.)

Signal loss detection alarm (See page 68.) Motion sensor alarm (See page 67.)
A video recording device can be used to record camera images and alarm images taken during monitoring.
Program recording (See page 56.) Active recording (See page 64.)

Records camera images Recording priority is given to alarm images.
By using the timer function, a single day can be divided into four different time and each camera can be operated separately during each time zone.

6:00 – 11:00 11:00 – 13:00 13:00 – 18:00 18:00 – 6:00
Images from cameras 1, 3, 5 and 6 are switched automatically
Images from cameras 8, 9, 10 and 16 are switched automatically
Images from cameras 7, 11, 12 and 13 are switched automatically
Images from cameras 4, 6, 9, 12 and 16 are switched automatically
Automatic switching display and recording of different camera images can be specified for each time zone. Furthermore, if sensor alarms are set, intruders can be detected during those time zones.
Monitor

Viewing a single-screen image
Press the LIVE button.
The camera image appears as a split-screen.
Setting the camera image to single-screen display


To cancel the still image, press the STILL button once more.
Pausing will be canceled and normal images will appear. Note: If you press the ZOOM button while the image is paused, the still image
will be enlarged. To return to the original still image, press the ZOOM button once more.


The images will be enlarged. Note: If you set a zoom frame, the area of the image inside the zoom frame will
If you press the camera select button while zooming, the image will be easier to see due to the movement of the subject. The following changes will occur if you press the camera select button repeatedly.

To return an enlarged image to normal image display, press the ZOOM button once more.
The zoom will be canceled and normal images will appear.
Image with large

You can select the zoom position by means of the zoom frame which appears on the screen. The position of the zoom frame is initially set to the middle of the screen.
Press camera select button 2.
The camera 2 image will appear in a single-screen display.
Press the ZOOM button.
The images will be enlarged.
Press and hold camera select button 2 for about 3 seconds or more.
The zoom will be canceled and the normal image will appear, and the zoom frame (G) will appear on the screen. Note: If the zoom frame remains on the screen for about 10 seconds without
being adjusted, the screen will return to zoom display. To make the zoom frame reappear, press and hold camera select button 2 again for 3 seconds or more.
Press the cursor button to move the zoom frame to the position you wish to enlarge.
Press camera select button 2 once more.
The image in the repositioned zoom frame will be enlarged. Note: If you press the STILL button while the images are being zoomed, an
enlarged still image will be displayed.
To return an enlarged image to normal image display, press the ZOOM button once more.
The zoom will be canceled and normal images will appear.

Viewing multiple-screen images
Images from the cameras that are connected to the multiplexer can be displayed in several split-screen formats. Furthermore, the images from each camera can be displayed in any position within the split screen. (See page 41.)
Press the LIVE button.
Viewing images as 9-screen or 16-screen displays
Press the MULTI button.
The display switches between 9-screen and 16-screen displays each time the MULTI button is pressed. To return to a single-screen display, press a camera select button.
For the MPX-CD93 model, only the 9-screen display is available with no switching.
Press the QUAD button.
Images appear as a 4-screen display.
Press the QUAD button once more.
Camera images are switched in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16) each time the button is pressed. To return to a single-screen display, press a camera select button.
For the MPX-CD93 model, a 4-screen display of images from cameras 1 – 4, 5 – 8, or 9 – 3 will appear each time the button is pressed.

The plus screen allows you to display the image from each camera as a quarter-screen picture in the lower right corner of the split-screen display, and images being recorded or played back can be monitored.
Press the PLUS button.
The display changes to show a 13-screen display with a plus screen as a quarter-screen picture in the lower-right corner.
For the MPX-CD93 model, a 6-screen display appears.
Press the MULTI button.
The display switches between 13-screen and 6-screen each time the MULTI button is pressed.
Press a camera select button (example: 12).
The images from the selected camera will be displayed in the plus screen. To cancel the plus screen, press the PLUS button once more.
For the MPX-CD93 model, press a camera select button numbered 9 or less.
Plus screen

Viewing automatically switching images
The camera images are switched automatically in the order that has been set using the SEQUENCE settings. (See page 43.)
Press the LIVE button.
Automatically switching of the single-screen images

Press the camera select buttons (example: 1, 5, 7) to select the camera numbers for automatic switching.
The camera select buttons for the cameras that were selected are stored in memory. The indicator lamp will light up when the next button is pressed.
Press the SEQUENCE button.
Camera images will be switched automatically in the order 1, 5 and 7.
To cancel automatic switching, press the SEQUENCE button.
Automatic switching will be canceled and normal images will appear.


Press the SEQUENCE button.
Camera images will be switched automatically in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16). For the MPX-CD93 model, images from cameras 1 – 4, 5 – 8, or 9 – 3 will be switched automatically.
Press the SEQUENCE button once more to return to the 4-screen display.
Automatic switching will be canceled and 4-screen display will be restored.

Press the SEQUENCE button.
The camera images in the plus screen will be switched automatically.
Press the SEQUENCE button once more to return to the plus screen.
Automatic switching will be canceled and the plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Set the recording device to playback mode.
Press the PLUS button.
The plus screen is displayed.
Press the VCR button.
This sets the plus screen to video playback mode.
Press the SEQUENCE button.
The playback images in the plus screen will be switched automatically.
Press the SEQUENCE button once more to return to the plus screen.
Automatic switching will be canceled and the plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Playing back recorded images in a single-screen display
Press the VCR button to playback from the connected recorder.
through this unit, it will not be displayed correctly. “NO ID” will appear on the screen.

The recorded images will be played back in a single-screen.

To return a still image to normal image display, press the STILL button once more.
Pausing will be canceled and normal images will appear. Note: If you press the ZOOM button while an image is paused, the still image
will be enlarged. To return to the original still image, press the ZOOM button once more.

The images will be enlarged. Note: If you set a zoom frame, the area of the image inside the zoom frame will
To return an enlarged image to normal image display, press the ZOOM button once more.
The zoom will be canceled and normal images will appear.

You can use the zoom frame that appears on the screen to select the position you wish to enlarge. The zoom frame is set initially at the center of the screen.
Press camera select button 2.

The camera 2 image will appear in a single-screen display.
Press the ZOOM button.
The images will be enlarged.
Press and hold camera select button 2 for about 3 seconds or more.
The zoom will be canceled and the normal image will appear, and the zoom frame (G) will appear on the screen. Note: If the zoom frame remains on the screen for about 10 seconds without
being adjusted, the screen will return to zoom display. To make the zoom frame reappear, press and hold camera select button 2 again for 3 seconds or more.
Press the cursor button to determine the position you wish to enlarge.

Press camera select button 2 one more.
The area of the image inside the zoom frame will be enlarged. Note: If you press the STILL button while the images are being zoomed, an
enlarged still image will be displayed.
Press the ZOOM button once more to return the enlarged image to the normal image.
The zoom will be canceled and normal images will appear.

Playing back multiple-screen displays
Recorded images can be displayed in several split-screen formats. Furthermore, the images from each camera can be displayed in any position within the split-screen. (See page 41.)
Press the VCR button.
Playing back images as 9-screen or 16-screen displays
Press the MULTI button.
The display switches between 9-screen and 16-screen each time the MULTI button is pressed. To return to a single-screen display, press a camera select button.
For the MPX-CD93 model, only the 9-screen display is available with no switching.
Press the QUAD button.
Images appear as a 4-screen display.
Press the QUAD button once more.
Camera images are switched in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16) each time the button is pressed. To return to a single-screen display, press a camera select button.
For the MPX-CD93 model, a 4-screen display of images from cameras 1 – 4, 5 – 8, or 9 – 3 will appear each time the button is pressed.


The display changes to show a 13-screen or 6-screen display with a plus screen as a quarter-screen picture in the lower-right corner.
Press the MULTI button.
The display switches between 13-screen and 6-screen each time the MULTI button is pressed.
For the MPX-CD93 model, only the 6-screen display is available with no switching.
Press a camera select button (example: 12).
The playing back images from the selected camera will be displayed in the plus screen. To cancel the plus screen, press the PLUS button once more.
For the MPX-CD93 model, press camera select button 9.
Plus screen

Playing back automatically switching images
Recorded images are switched automatically in the order that has been set using the SEQUENCE settings. (See page 43.)
Press the VCR button.
Automatic switching of the single-screen playback images

Press the camera select buttons (example: 1, 5, 7).
Press the SEQUENCE button.
The recorded images are automatically switched in the order set.
To cancel automatic switching, press the SEQUENCE button once more.
Automatic switching will be canceled and normal images will appear.


Press the SEQUENCE button.
Camera images will be switched automatically in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16).
For the MPX-CD93 model, images from cameras 1 – 4, 5 – 8, or 9 – 3 will be switched automatically.
To cancel automatic switching, press the SEQUENCE button once more.
Automatic switching will be canceled and a 4-screen display will appear.

Press the SEQUENCE button.
The playback images in the plus screen will be switched automatically.
To cancel automatic switching, press the SEQUENCE button once more.
Automatic switching will be canceled and a plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Four monitors can be connected to the spot monitor output connectors on the rear panel of this unit. Even while the main monitor is showing camera images as split screens or playback, the camera images can be displayed on the spot monitors as single-screen or automatic switching images.

When the SPOT MON. button is pressed in camera image (LIVE) or playback (VCR) mode, each spot monitor goes into selection standby condition. If the SPOT MON. button is pressed once more, LIVE or VCR mode is enabled.

Spot monitor settings
SPOT MON. 1
Press the SPOT MON. button.
Camera select buttons 1 to 4 flash and spot monitor selection standby condition is enabled. Note:

Spot monitor indicator 4 and the SPOT MON. indicator will flash and S4 will appear (flashing) on the screen of spot monitor 4. Note: S1 to S4 will appear flashing on the
screen of each selected spot monitor.

Menu flowchart
(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
(CLOCK SET)
(DAY LIGHT SET)
01-01-2001 MON 00:00:00
WEEK MON TIME ON 1ST-SUN 04 02:00 OFF LST-SUN 10 02:00
TIMER ON ¤ DAY LIGHT ON ¤
ESPANOL
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A
TITLE DOWN ¤ MULTI SCREEN CHANGE¤ SEQUENCE INDIV.¤ MASK ON ¤ MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
(POSITION SET)
QUAD
01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16
(VCR SET)
(PROGRAM REC.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
(SEQUENCE SET)
MAIN MONITOR 1 S ¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S
(ALARM SET)
ALARM EXT.OR M.SENSOR
ALARM ON * ACTIVE REC. ON * MOTION SENSOR ON * VIDEO LOSS OFF
DURATION INDIV.* RETRIGGER ON ALARM LIST ON BUZZER ON
(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF
AL.REC.EXT.
CAMERA NO.01 T-1 LEVEL:OFF MODE:A
ALARM DISPLAY FULL DOUBLE ALARM LAST
(SPOT MONITOR SET)
SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON
(SEQURITY LOCK SET)
OPERATION CODE 1111 LOCK ON
SECURITY CODE ----
SETUP CODE 1111 LOCK ON
(CAMERA CONTROL SET)
(CONTROL SET)
DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C
IN IN 01:OFF 09:0FF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

Menu operations
The MAIN MENU screen will be displayed. Note: The MAIN MENU screen will appear on the main monitor and on spot
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
monitor 1.
NEXT NEXT

(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A


1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
The multiplexer menu screens can be displayed in several languages (English, French or Spanish). The default language setting is English.
The MAIN MENU screen will be displayed.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “LANGUAGE” and then press the NEXT button.
The LANGUAGE screen will be displayed.
FRANCAIS
ESPANOL
Use the cursor button to select the language, and then press the MENU button.
The selected language will be set. The camera images will be displayed.
FRANCAIS
ESPANOL

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
01-01-2001 MON 00:00:00
Set the timer when using the timer function.
(*:NEXT) (TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A
WEEK MON TIME ON 1ST-SUN 04 02:00 OFF LST-SUN 10 02:00
The CLOCK SET menu is used to set the time. It is also used to set a timer when using the timer function, and to make daylight saving settings.
Clock setting · Timer setting · Daylight saving setting

CLOCK SET SETTINGS
Clock settings (default setting: 01-01-2001 MON 00:00:00)
Be sure to set the clock to the correct time. The correct time must be set in order for the timer setting and summer time setting functions to work correctly.
The MAIN MENU screen will be displayed.
(MAIN MENU)
(CLOCK SET)
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
(CLOCK SET)
10-15-2002 TUE 15:20:00
Use the cursor button to select “CLOCK SET”, and then press the NEXT button.
The time setting is finished.
the date entered.
The CLOCK SET screen will be displayed.
To display date, time and camera number
01-01-2001 MON 00:00:00
BACK
While the camera image is displayed, press the BACK button repeatedly. The following actions will occur:
Use the cursor button to select “01”, and then use the setting buttons to set the date.
01 Date, time and camera number
01-01-2001 MON 00:00:00
TIMER ON * DAY LIGHT OFF
10-15-2002 15:20:00 10-15-2002 15:20:00 01
Time is displayed.
00 during monitoring Press the MENU RESET button. The minutes and seconds will then be reset to 00.
10-01-2001 MON 00:00:00
while camera images are being displayed. If you press these buttons while a menu screen is being displayed, the setting values will be reset to their defaults. CLOCK SET-1
10-15-2001 MON 00:00:00
Date and time

CLOCK SET SETTINGS
TIMER settings (default setting: 00:00)
For these settings, set Example 2 consecutively with Example 1. Example1: Set TIMER-A and TIMER-B time
The timer function uses two separate timer settings (TIMER-A and TIMER-B), and each timer setting can be made in four time zones (example: midnight, morning, daytime, evening). For example, TIMER-A time zones can be set for automatic screen switching and TIMER-B time zones can be set for gray pattern cover on camera images.
(TIMER-A settings) (TIMER-B settings) T-1 4 a.m. (4:00) T-1 6 a.m. (6:00) T-2 6 a.m. (6:30) T-2 8 a.m. (8:00) T-3 12:30 p.m. (12:30) T-3 2:30 p.m. (14:30) T-4 6 p.m. (18:00) T-4 8 p.m. (20:00)
Press the MENU button, use the cursor button to select CLOCK SET and then press the NEXT button.
period set by the timer
Each of the following menu settings is required to operate these timer functions. After you have made the menu settings, be sure to make the timer settings.
Use the cursor button to select TIMER “OFF”.
(DISPLAY SET)
10-15-2001 MON 15:20:00
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Press the setting buttons to select “ON”, and then press the NEXT button.
The TIMER SET screen will be displayed.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
10-15-2001 MON 15:20:00
TIMER ON * DAY LIGHT OFF
PROGRAM REC. ONLY *
Use the cursor button to select TIMER-A “T-1 00:” (hours), and then use the setting buttons to set the hours to “4”.
ALARM OFF ACTIVE REC. OFF MOTION SENSOR ON * VIDEO LOSS OFF
(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

CLOCK SET SETTINGS
Use the cursor button to select TIMER-A “T-1 :00” (minutes), and then use the setting buttons to set the minutes to “00”.
+ – 5
screen and monitor mask. To set TIMER-B timer zones to program recording and
motion sensor.
(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
Use the cursor button to select SEQUENCE “A”, and then use the setting buttons to set “A”. (TIMER-A setting)
Use the cursor button to select TIMER-A “T-2 00:” (hours), and then use the setting buttons to set the hours to “6”.
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A
(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 06:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
Use the cursor button to select PROGRAM REC “A”, and then use the setting buttons to set “B”. (TIMER-B setting)
Use the cursor button to select TIMER-A “T-2 00” (minutes), and then use the setting buttons to set the minutes to “30”.
SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A
(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 06:30 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
Use the cursor button to select MASK “A”, and then use the setting buttons to set “A”.
Repeat steps 4 and 5 to set the hours and minutes for T-3 and T-4 also.
SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A
Use the same procedure to set the hours and minutes for T-1, T-2, T-3 and T-4.
Use the cursor button to select MOTION SENSOR “A”, and then use the setting buttons to set “B”.
SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A
(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 06:00 T-2 06:30 T-2 08:00 T-3 12:30 T-3 14:30 T-4 18:00 T-4 20:00
Press the BACK button.
The setting will then be completed and the display will return to the CLOCK SET screen. Press the BACK button once more to return to the MAIN MENU screen. CLOCK SET-3

CLOCK SET SETTINGS
DAY LIGHT setting (default setting: OFF)
You can set the starting time and ending time for daylight. When daylight is set, the time is automatically advanced by one hour during the summer period.
(first, second, third, fourth or last)

WEEK MON TIME ON 2ND-SUN 04 02:00 OFF LST-SUN 10 02:00
second Tuesday of May at 3:00 AM, to the fourth Tuesday of September at 3:00 AM.
Press the MENU button, use the cursor button to select CLOCK SET and then press the NEXT button.
WEEK MON TIME ON 2ND-TUE 04 02:00 OFF LST-SUN 10 02:00
(for January, February, March December)
Use the cursor button to select DAY LIGHT “OFF”.

WEEK MON TIME ON 2ND-TUE 05 02:00 OFF LST-SUN 10 02:00
TIMER OFF DAY LIGHT OFF
WEEK MON TIME ON 2ND-TUE 05 03:00 OFF LST-SUN 10 02:00
Press the setting buttons to change the setting to ON, and then press the NEXT button.
Following the same procedure as above, set when the time is changed back from daylight to standard time (the OFF settings).
The DAY LIGHT SET screen will be displayed.
10-15-2001 MON 15:30:00
WEEK MON TIME ON 2ND-TUE 05 03:00 OFF 4TH-TUE 09 03:00
The display will return to the normal screen. CLOCK SET-4

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
CAMERA NO.01 ------- 001
CAMERA NO.01 CAM DESK 001
(DISPLAY SET)
TITLE DOWN ¤ MULTI SCREEN CHANGE¤ SEQUENCE INDIV.¤ MASK ON ¤ MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
(MAIN MON.SEQ SET) T-4 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 06:ON 14:ON 07:ON 15:ON 08:ON 16:ON
(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:OFF 10:ON 03:OFF 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:OFF 14:OFF 07:OFF 15:ON 08:OFF 16:OFF
01-01-2002 TUE 00:00:00
TIMER ON ¤ DAY LIGHT ON *
(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A
(PROGRAM REC.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON
(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON
(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON
(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

DISPLAY SET SETTINGS
TITLE setting (default setting: DOWN)
A title such as the setup location can be set for each camera, and the position for displaying this title on the monitor screen can also be changed. Example: To assign a title of “HALL-1F” to camera 3 and set the display position to the top of
Press camera select button 3.
The MAIN MENU screen will be displayed.
The images from camera 3 will be displayed on the monitor, and the cursor will appear at the default title setting position.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
Use the setting buttons to display “H”, and then press the cursor button.
The DISPLAY SET screen will be displayed.
If the cursor button is pressed to the right, the cursor will move to the right. Use this procedure to enter “HALL-1F”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
If the title is to be altered, use the cursor buttons to bring the cursor to the item that is to be changed and select a setting button.
Use the cursor button to select TITLE “DOWN”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S
Use the setting buttons to select “UP”, and then press the NEXT button.
The normal monitoring screen will be displayed and the title will appear at the top of the screen.
BACK button and then re-select “UP” or “DOWN” for the TITLE setting.
TITLE UP ¤ MULTI SCREEN NORMAL SEQUENCE 1 S
Press the BACK button.
The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen. DISPLAY SET-1

DISPLAY SET SETTINGS
MULTI SCREEN setting (default setting: NORMAL)
The order in which camera images are displayed in 4-screen, 9-screen and 16-screen displays can be set as desired. Note: The same camera image cannot be displayed more than once on the same screen.
The MPX-CD93 model can display only cameras 01 to 09.
Use the cursor button to move the cursor to “06”, and then press the setting buttons to change the setting to “01”.
The MAIN MENU screen will be displayed.
06 will change to 01.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16
01 02 : 05 01 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
The DISPLAY SET screen will be displayed.
Repeat step 5 to set the images in 01 to 11 and 16 also.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
You can check the setting by pressing the NEXT button. Press the NEXT button once more to return to the setting screen.
Use the cursor button to select MULTI SCREEN “NORMAL”.

01 02 : 05 01 03 04 : 07 08 09 10 : 13 14 01 12 : 15 01
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the setting buttons to select “CHANGE”, and then press the NEXT button.
A 4-screen camera layout screen will be displayed.
TITLE DOWN ¤ MULTI SCREEN CHANGE* SEQUENCE 1 S MASK OFF
Press the BACK button.
The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.
QUAD
01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16

DISPLAY SET SETTINGS
Use the setting buttons to select “CHANGE”, and then press the NEXT button.
TITLE DOWN ¤ MULTI SCREEN CHANGE* SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
A 4-screen camera layout screen will be displayed.
Use the setting buttons to call up the 16-screen setting screen.
The display changes to a 9-screen, 16-screen and 4-screen display in that order.
(POSITION SET)
MULTI16
(POSITION SET)
MULTI9
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
01 02 03 04 05 06 07 08 09
01 02 : 05 06 03 04 : 07 08 + 09 10 : 13 14 11 12 : 15 16
The “MULTI16” screen is not available on the MPX-CD93 model.
Use the cursor button to move the cursor to “05”, and then press the setting buttons to change the setting to “16”.
(POSITION SET)
MULTI16
MULTI16
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
01 02 03 04 16 06 07 08 09 10 11 12 13 14 15 05
05 will change to 16 and 16 will change to 05.
You can check the setting by pressing the NEXT button. Press the NEXT button once more to return to the setting screen.
Press the BACK button.
The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen. DISPLAY SET-3

DISPLAY SET SETTINGS
SEQUENCE setting (default setting: 1S)
This lets you set the automatic switching time. The switching time setting for automatic switching display is only effective for single-screen and 4-screen displays. Two types of setting can be made: all cameras can be switched at the same time, or the switching times can be set separately for each camera. Example 1: To set 5-second intervals for automatic switching display of all main and spot
BACK 5
Press the BACK button.
The MAIN MENU screen will be displayed.
The setting will then be completed and the display will return to the MAIN MENU screen. When the MENU button is pressed, the display returns to camera image display screen.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Press the SEQUENCE button while the camera image display screen is displayed.
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
The screen will switch to 5-second intervals. To stop the screen from switching, press the SEQUENCE button once more. DISPLAY SET-4
The DISPLAY SET screen will be displayed.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the cursor button to select SEQUENCE “1S”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the setting buttons to select “5S”.
Images can then be switched at intervals of 5 seconds.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 5 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET SETTINGS
Example 2: To set the automatic switching period for the main monitor.
camera are the same as for the main monitor).
Use the cursor button to select SEQUENCE “1S”.
Use the cursor button to select “01:1S”, and then press the setting buttons to change the setting to “2S”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Automatic switching display at the specified switching interval is enabled when you have entered a switching period for each camera.
Use the setting button (–) to select “INDIV.”, and then press the NEXT button.
With the same procedure:
The SEQUENCE SET screen will be displayed.
(INDIVIDUAL INTERVAL)
IN IN 01: 1 S 09: 1 S 02: 1 S 10: 1 S 03: 1 S 11: 1 S 04: 1 S 12: 1 S 05: 1 S 13: 1 S 06: 1 S 14: 1 S 07: 1 S 15: 1 S 08: 1 S 16: 1 S
IN IN 01: 2 S 09: 3 S 02: 2 S 10: 3 S 03: 2 S 11: 3 S 04: 2 S 12: 3 S 05: 2 S 13: 3 S 06: 2 S 14: 3 S 07: 2 S 15: 3 S 08: 2 S 16: 3 S
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Press the BACK button.
Use the cursor button to select the MAIN MONITOR “1S” setting, and then press the setting buttons (–) to change the setting to “INDIV.”.
The setting will then be completed. Press the BACK button once more to return to the MAIN MENU screen.
INDIV. INTERVAL appears at the bottom of the screen.
The display will return to the camera image display screen. If the SEQUENCE button is then pressed, the screen images will start switching automatically according to the settings that have been made. DISPLAY SET-5
MAIN MONITOR INDIV.¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S
Use the cursor button to select “INDIV. INTERVAL” and then press the NEXT button.
The INDIVIDUAL INTERVAL screen will be displayed.
MAIN MONITOR INDIV.¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S

DISPLAY SET SETTINGS
images and to use the timer function to set a period when automatic switching display is not required. 1 Set “TIMER” on CLOCK SET to ON, set each timer
Use the cursor button to select the MAIN MONITOR “1S” setting, and then press the setting buttons to change the setting to “5S”.
of TIMER-A and TIMER-B on TIMER SET to SEQUENCE and terminate CLOCK SET.
The automatic switching period for the main monitor will be set to 5 seconds.
The MAIN MENU screen will be displayed.
MAIN MONITOR 5 S ¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Press the NEXT button. The MAIN MON. SEQ. SET “T-1” screen will be displayed.
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
This screen is for selecting whether images from cameras 1 to 16 will be displayed at the time specified by the timer (T-1). Note: T-1 will not be displayed if TIMER on
The DISPLAY SET screen will be displayed.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
CLOCK SET is OFF.
(MAIN MON.SEQ.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 06:ON 14:ON 07:ON 15:ON 08:ON 16:ON
Use the cursor button to select SEQUENCE “1S”.
Use the cursor button to select “example: 01:ON”, and then press the setting buttons to change the setting to “OFF”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the same procedure to set OFF cameras 2 (02) to 08.
Use the setting button (–) to select “INDIV.” and then press the NEXT button.
(MAIN MON.SEQ.SET) T-1 IN IN 01:OFF 09:ON 02:OFF 10:ON 03:OFF 11:ON 04:OFF 12:ON 05:OFF 13:ON 06:OFF 14:ON 07:OFF 15:ON 08:OFF 16:ON
The SEQUENCE SET screen will be displayed.
DISPLAY SET-6
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the cursor button to select “T-1”, and then press the setting buttons to change the setting to “T-2”.
The display will return to the camera image display screen. If the SEQUENCE button is then pressed, the screen images will start switching automatically according to the settings that have been made.
Press the setting buttons repeatedly to switch T-1, 2, 3, 4.
Example of automatic switching display
(MAIN MON.SEQ.SET) T-3
(MAIN MON.SEQ.SET) T-4
Use the cursor button to select “example: 09:ON”, and then press the setting buttons to change the setting to “OFF”. Use the same procedure to set OFF cameras 10 (10) to 16.
(MAIN MON.SEQ.SET) T-2 IN IN 01:ON 09:OFF 02:ON 10:OFF 03:ON 11:OFF 04:ON 12:OFF 05:ON 13:OFF 06:ON 14:OFF 07:ON 15:OFF 08:ON 16:OFF
set with the same operations as in steps 9 to 10.
Press the BACK button.
The setting will then be completed and the display will return to the SEQUENCE SET screen. Press the BACK button once more to return to the DISPLAY SET screen.

MASK settings (default: OFF)
If you do not need images from some cameras to appear on the monitor screen, you can cover these camera images with gray patterns. Example 1: To prevent monitoring of images from cameras 5 (05) to 10
For the MPX-CD93 model, the settings are from cameras 01 to 09. 1 Set TIMER on CLOCK SET to OFF.
Use the cursor button to select “05:OFF”, and then press the setting buttons to change the setting to “ON”.
If TIMER has been set to ON, a display such as T-1 will appear when the timer is set.
Use the same procedure to set from 6 to 10 to “ON”.
The MAIN MENU screen will be displayed.
(MASK SET) T-1 IN IN 01:OFF 09:ON 02:OFF 10:ON 03:OFF 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:ON 14:OFF 07:ON 15:OFF 08:ON 16:OFF
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Press the BACK button.
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.
The DISPLAY SET screen will be displayed.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
The display will return to the camera image display screen. Display example:
Use the cursor button to select MASK “OFF”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the setting buttons to select “ON”, and then press the NEXT button.
The MASK SET screen will be displayed.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO


+ – 6
Use the cursor button to select “example: 02:OFF”, and then press the setting buttons to change the setting to “ON”.
of TIMER-A and TIMER-B on TIMER SET to MASK and terminate CLOCK SET.
Use the same procedure to set 04, 06, 08 and 10 to “ON”.
The MAIN MENU screen will be displayed.
(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 06:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “T-1”, and then press the setting buttons to change the setting to “T-2”.
Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
The DISPLAY SET screen will be displayed.
The MASK SET “T-2” screen will be displayed. Press the setting buttons repeatedly to switch T-1, 2, 3, 4.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
(MASK SET) T-3
(MASK SET) T-4
Use the cursor button to select MASK “OFF”.
Use the cursor button to select “example: 01:OFF”, and then press the setting buttons to change the setting to “ON”.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the same procedure to set 03, 05, 07 and 09 to “ON”.
Use the setting buttons to select “ON”, and then press the NEXT button.
If you wish, T-3 and T-4 may be set with the same operations as in steps 6 to 7.
The MASK SET screen will be displayed. This screen is for selecting whether images from cameras 1 to 16 will be masked at the time specified by the timer (T-1).
(MASK SET) T-2 IN IN 01:ON 09:ON 02:OFF 10:OFF 03:ON 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:OFF 14:OFF 07:ON 15:OFF 08:OFF 16:OFF
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET SETTINGS
Press the BACK button.
BACK 9
The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.
The same camera images that are being displayed on the main monitor can also be displayed on spot monitor 1. This feature can be used to allow another person to monitor the 16-screen display (spot monitor 1) in another room.
The camera image display menu is restored. At the time specified by the timer settings, the specified camera images will be covered with a gray pattern.
The MAIN MENU screen will be displayed.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.
The DISPLAY SET screen will be displayed.
T – 1 (6:00 – 12:00) T – 2 (12:00 – 16:00)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
Use the cursor button to select MAIN→SPOT1 “OFF”, and then press the setting buttons to change the setting to “ON”.
T – 3 (16:00 – 24:00) T – 4 (24:00 – 6:00)
When set to “ON”, identical images will be displayed on both the main monitor and spot monitor 1.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 ON DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET SETTINGS
Press the MENU button to terminate the operation of this unit.
5 Use the same procedure to specify other
connections
sub-units (SUB2, 3).
For making connections, please refer to “Digital connections”. (See page 9.)
When the main unit and sub-units have been specified, the camera images of the main unit will appear on the monitor and only the main unit can be controlled. The indicator lamps of all other sub-units will be turned off. When another sub-unit is to be controlled, press the LIVE button of the other sub-unit. The sub-unit indicator will illuminate, the main unit lamp will turn off, and the camera image of the sub-unit will appear on the monitor.
+ – 1
Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select MAIN.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION MAIN COLOR LEVEL AUTO
recorder (sold separately) to this unit
For making connections, please refer to “Digital connections”. (See page 10.)
Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select DVR.
Press the MENU button to terminate the operation of this unit.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION DVR COLOR LEVEL AUTO
Press the MENU button to terminate the operation of this unit.
+ – 3
Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select SUB1.
(DISPLAY SET)
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION SUB1 COLOR LEVEL AUTO

DISPLAY SET SETTINGS
Method of control
COLOR LEVEL settings
To play back a digital video recorder (sold separately) from this unit 1. Make the following setting on the digital video recorder’s VIDEO INPUT SET menu.
To adjust the monitor screen color level.
Use the cursor buttons to select COLOR LEVEL “AUTO” and then press the setting buttons to adjust the color level.
TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO
recorder for details on the VIDEO INPUT setting. 2. Press the VCR button on this unit and press the cursor (c) button.
The digital video recorder playback image will appear on the monitor.
signal is extremely attenuated by the effect of a cable, for example, color can be forcibly applied. DISPLAY SET-12
While it is operating, the digital video recorder indicator will illuminate or flash. (Cursor buttons) 1 j: Still image 2 c: Playback 3 d: Reverse play 4 l: Stop 5 (NEXT button) If you press this button when several digital video recorders are connected, you will be switched in sequence from the digital video recorder nearest to this unit. (Setting buttons) 6 +: Increase playback speed 7 –: Decrease playback speed
(RS-485).


This lets you select a recording device for recording camera images. The recording speed for these recorded images and the recording speed when there is an alarm can be selected, and the recording method to be used for recording camera images can also be selected.

VCR SET SETTINGS
VCR SET settings are for specifying how a unit to record images from a camera will carry out the recording.
The MAIN MENU screen will be displayed.
1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
Use the cursor button to select “VCR SET” and then press the NEXT button.
The VCR SET screen will be displayed.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
If the recording unit does not have a SW signal output connector
+ – 3
Use the cursor button to select RECORDER (example: TLS), and press the setting buttons.
Match REC. SPEED and ALARM REC. SPEED of this unit to the recording speed of the recording unit that is connected. Settings are not required for a digital video recorder.
Use the setting buttons to switch the recording unit.

When a time lapse VCR is selected
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H
When a real time VCR is selected
RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H
When a digital video recorder is selected
RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S

VCR SET SETTINGS
Use the cursor button to select REC. SPEED (example: 2H), and press the setting buttons to set the recording speed.
Use the cursor button to select ALARM REC. SPEED (example: 2H), and press the setting buttons to set the alarm recording speed.
+ – 5
(VCR SET)
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
2, 12, 24, 48, 72, 96, 120, 168, 240, 360, 480, 720, 960
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
PROGRAM REC. OFF
PROGRAM REC. OFF
speed when an alarm is received. F2: Use this setting when using the SW signal output
connector of a VCR and no switch signal is output for 2 H.
RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H SW.IN EDGE ñ REC.PICTURE 01
6, 18, 30, 48, 72, 96, 120, 168, 240, 360, 480, 720, 960
(VCR SET)
RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H SW.IN EDGE ñ REC.PICTURE 01
recording speed for the video device as follows.
Multiplexer recording speed Real time VCR recording
6 (6 hours) 8H (8 hours)
18 (18 hours) 24H (24 hours)
speed when an alarm is received. F6: Use this setting when using the SW signal output
30 (30 hours) 40H (40 hours)
connector of a VCR and no switch signal is output for 6 H.
(VCR SET)
RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S SW.IN EDGE ñ REC.PICTURE 01
0.02, 0.03, 0.05, 0.07, 0.10, 0.13, 0.17, 0.20, 0.23, 0,27, 0.30, 0,33, 0.37, 0.43, 0.50, 0.60, 0.70, 0.80, 0.90, 1, 2, 3, 4, 5, 10, 20, 30 S
RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S SW.IN EDGE ñ REC.PICTURE 01
0.02, 0.03, 0.05, 0.07, 0.10, 0.13, 0.17, 0.20, 0.23, 0,27, 0.30, 0,33, 0.37, 0.43, 0.50, 0.60, 0.70, 0.80, 0.90, 1, 2, 3, 4, 5, 10, 20, 30 S, NC
PROGRAM REC. OFF
even if an alarm is received.
speed is 2H or 6H, even though the recording device has a SW signal output connector. If this happens, set the alarm recording speed as follows.
Recording speed Alarm recording
speed Time lapse VCR 2H F2 Real time VCR 6H F6 VCR SET-2
speed

VCR SET SETTINGS
Use the cursor button to select SW. IN EDGE (example: ↓), and then press the setting buttons.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
Display examples:
Use the cursor button to select REC. PICTURE (example: 01), and then press the setting buttons.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

PROGRAM REC. setting
1, 2 and 3 in MODE 1
The MAIN MENU screen will be displayed.
Only images from cameras selected (ON) are recorded.
1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
Use the cursor button to select “VCR SET” and then press the NEXT button.
The VCR SET screen will be displayed.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
Images from cameras selected (ON) and images from all cameras are recorded alternately.

Use the cursor button to select PROGRAM REC. “OFF”, press the setting buttons to change the setting to “MODE1”, and then press the NEXT button.
The PROGRAM REC. SET screen will be displayed. Refer to the display example to select program recording.

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

VCR SET SETTINGS
Use the cursor button to select “example: 04:ON”, and then press the setting buttons to change the setting to “OFF”.
Now camera 4 cannot be recorded. Use the same procedure to set 05 – 16 to “OFF”.
IN IN 01:ON 09:OFF 02:ON 10:OFF 03:ON 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 05:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF
Press the BACK button, and then press the MENU button.
The display returns to the MAIN MENU screen.
Carry out the necessary steps at the recording device to start recording. The images from cameras 1, 2 and 3 that are set to ON will be recorded in the MODE1 format.

VCR SET SETTINGS
Example 2: To record in MODE2 using the
Use the cursor button to select “T-1”, and then press the setting buttons to change it to “T-2”.
For the MPX-CD93 model, please specify cameras 1 to 9.
The (PROGRAM REC. SET) T-2 screen will be displayed.
The MAIN MENU screen will be displayed.
(PROGRAM REC.SET) T-2 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 05:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “02:ON”, and then press the setting buttons to change the setting to “OFF”.
Use the cursor button to select TIMER “OFF” in the CLOCK SET menu, press the setting buttons to change the setting to “ON”, and then press the NEXT button.
Use the same procedure to set 04, 06, 08, 10, 11, 12, 13, 14, 15 and 16 to “OFF” also. Repeat steps 5 and 6 to change the settings for T-3 and T-4.
Once the timer settings have been made, the display returns to the MAIN MENU screen with “VCR SET” selected.
Press the BACK button.
Use the cursor button to select “MODE2” and then press the NEXT button.
Once the setting is complete, the display will return to the VCR SET screen. Press the BACK button once more to return to the MAIN MENU screen.
RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01
Press the MENU button and then start recording.
Carry out the necessary steps at the recording device to start recording. Camera images will be recorded in MODE2 using the timer function.
Use the cursor button to select “example: 01:ON”, and then press the setting buttons to change the setting to “OFF”.
Use the same procedure to set 03, 05, 07, 09, 11, 12, 13, 14, 15 and 16 to “OFF” also.
(PROGRAM REC.SET) T-1 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 05:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF

Alarm setting (See page 61.)
Lets you make various alarm settings.
1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
(ALARM DISPLAY SET)
ALARM EXT.OR M.SENSOR
ALARM DISPLAY FULL DOUBLE ALARM LAST
DURATION INDIV.* RETRIGGER OFF ALARM LIST ON BUZZER ON
SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON
Active recording setting (See page 64.)
Select the type of alarms to record.
(ACTIVE REC.SET)
AL.REC. EXT. REC.MODE MODE1
ALARM ON * ACTIVE REC. ON * MOTION SENSOR ON * VIDEO LOSS FREEZE
Select which recording method to use for recording.
Multiple alarm images are recorded alternately.
MODE2
Multiple alarm images are recorded alternately.
If the motion sensor has been set and a suspicious person is detected, alarm recording is carried out for the length of time set by the timer.
Alarm Alarm canceled ONLY
Recording continues until the alarm is canceled.
Timer setting (See page 36.)
Sets monitoring sensors. Motion sensor alarm setting (See page 67.)
01-01-2001 MON 00:00:00
TIMER ON ¤ DAY LIGHT OFF
AAAAAA AAAAAA AAAAAA
(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00
SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A
When camera images are lost, the screen appears as a still image or a test pattern.
VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS
Test pattern Still image

There are three types of alarm detection: external alarm, motion sensor alarm and no signal alarm. Alarm settings include specifying the period during which the buzzer will continue to sound and the method of recording images during each alarm.
External alarm detection By setting up a door switch, etc. connected to the alarm input connecter at the rear of this unit, an intruder opening or closing the door can be detected. When it is detected, the buzzer will sound.
When an alarm occurs, the indicator on the camera select button for the camera that produced the alarm (example: 4) will start flashing.
The image from the camera that produced the alarm (example: 4) will be displayed and “EA” (external alarm) will appear on the screen.
When an alarm occurs, the alarm history is recorded in the alarm list. The histories of up to 100 events can be displayed.
Motion sensor alarm detection By setting the sensitivity of a motion sensor built into this unit an intruder can be detected on the monitor screen and the buzzer will sound.
The image from the camera that produced the alarm (example: 4) will be displayed and “SA” (sensor alarm) will appear on the screen.
(ALARM LIST) 1/13 CAM DATE TIME ITEM 1 4 08-22 08:48 E 2 2 08-21 08:51 S 3 4 05-04 16:22 E 4 3 05-04 07:45 V 5 1 04-30 14:37 E 6 1 04-21 18:26 V 7 2 04-12 05:31 E 8 4 04-12 12:51 E
CAMERA NO.04 T-1 LEVEL:OFF MODE:A
The codes in the ITEM column indicate the type of alarm data. E: External alarm trigger S: Motion sensor trigger V: Video loss
Signal loss detection alarm In the case of a camera signal being suddenly interrupted due to an accident, etc., a setting can be made to record the image immediately prior to the interruption (a still image or a test pattern). When it is detected the buzzer will sound.
When an alarm occurs, the screen changes to a still image or a test pattern, and the video loss detection alarm display (VIDEO LOSS) will appear on the screen.

ALARM SET SETTINGS
ALARM SET settings Example: To use both an external alarm and
The MAIN MENU screen will be displayed.
Use the cursor button to select DURATION “10S”, and then press the setting buttons to select “5”.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
An alarm display time of 5 seconds has been set.
ALARM EXT.AND M.SENSOR
Use the cursor button to select “ALARM SET” and then press the NEXT button.
DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON
The ALARM SET screen will be displayed.
1, 2, 3, 4, 5, 10, 20 ... (in 10-second intervals), 180S, CC, NC, INDIV.
ALARM ON * ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF
Use the cursor button to select ALARM “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.
Use the cursor button to select RETRIGGER “OFF”, and then press the setting buttons to select “ON”.
The ALARM OPERATION SET screen will be displayed.
ALARM EXT.AND M.SENSOR
DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON
Use the cursor buttons to select ALARM “EXT. OR M.SENSOR”, and then press the setting buttons to select the “EXT. AND M. SENSOR”.
ALARM EXT.AND M.SENSOR
DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON
Display examples: The following four alarm detection methods are available.

ALARM SET SETTINGS
Use the cursor button to select ALARM LIST “ON”.
+ – 7
The number of the camera where the alarm was detected, the date, time and the type of alarm are recorded in the alarm list.
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
ALARM EXT.AND M.SENSOR
DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON
DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON
ALARM DISPLAY ¤
Display examples:
Use the setting buttons to select “INDIV.”, and then press the NEXT button.
The ALARM DURATION SET screen will be displayed.
Use the cursor button to select BUZZER “ON”.
The buzzer will sound when an alarm is detected.
DURATION INDIV.* RETRIGGER ON ALARM LIST ON BUZZER ON
ALARM EXT.AND M.SENSOR
ALARM DISPLAY ¤ (*:NEXT)
DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON
Use the cursor button to select “01:10S”, and then press the setting buttons to change the setting to “3S”.
Display examples:
Use the same procedure to set the alarm duration for cameras 02, 03, 04 and 05.
IN IN 01: 3 S 09:10 S 02: 3 S 10:10 S 03: 3 S 11:10 S 04: 3 S 12:10 S 05: 3 S 13:10 S
multiplexer. If setting the buzzer to sound, place the multiplexer so that the buzzer sound can be heard from the multiplexer. ALARM SET-2
The display will return to the camera image display screen. When an alarm is detected at the cameras that have been set, an alarm is displayed for the setting duration.
Cameras 01 to 05
Alarm displayed · for 3 seconds

ALARM SET SETTINGS
Use the cursor button to select DOUBLE ALARM “LAST”, and then press the setting buttons to select “example: FIRST”.
single-screen when an alarm is detected and another alarm has occurred. 1 Press the MENU button.
ALARM DISPLAY FULL DOUBLE ALARM FIRST
(SPOT MONITOR SET)
SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON
The MAIN MENU screen will be displayed. 2 Use the cursor button to select “ALARM SET”
and then press the NEXT button.
The ALARM SET screen will be displayed.

ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF
Use the cursor button to select ALARM “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.
SPOT MONITOR SET setting (default setting: ON) Example: When an alarm is detected, a
single-screen alarm image is displayed on four spot monitors.
Use the cursor button to select “ALARM DISPLAY” and then press the NEXT button.
Use the cursor button to select SPOT MONITOR-1 “ON”.
ALARM DISPLAY FULL DOUBLE ALARM LAST
(SPOT MONITOR SET)
DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON
SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON
Use the cursor button to select ALARM DISPLAY “FULL”.
Use the same procedure to set SPOT MONITOR-2, -3 and -4.

ALARM SET SETTINGS
ACTIVE REC setting (default setting: OFF)
The ACTIVE REC setting can be used to give priority to alarm images when recording images. You can set the type of alarms to be recorded and the recording method for recording alarm images.
Use the cursor button to select AL. REC. “EXT.”, and then press the setting buttons to select to “EXT. OR M. SENSOR”.
The MAIN MENU screen will be displayed.
(MAIN MENU)
Display examples:
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select REC. MODE “MODE1”, and then press the setting buttons to set to “MODE2”.
Use the cursor button to select “ALARM SET” and then press the NEXT button.
The ALARM SET screen will be displayed.
(ALARM SET)
AL.REC.EXT.OR M.SENSOR REC.MODE MODE2
ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF
Use the cursor button to select ACTIVE REC. “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.
The ACTIVE REC. SET screen will be displayed.
When an external alarm occurs, the alarm images will be recorded according to the MODE2 settings.
ALARM OFF ACTIVE REC. ON * MOTION SENSOR OFF VIDEO LOSS OFF
Display examples:




ALARM SET SETTINGS
MOTION SENSOR setting (default setting: OFF)
Example: To record images detected by the
motion sensor for the timer setting duration 1 Set the TIMER setting in the CLOCK SET menu to
To display motion sensors on each camera image and make settings for intruder detection. The motion sensors work as shown below.
“ON”, make the settings for TIMER-A and TIMER-B in the TIMER SET menu, and then select MOTION SENSOR and close the CLOCK SET screen.
AAAA BBBB
The MAIN MENU screen will be displayed.
(MAIN MENU)
3 5 4 6
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “ALARM SET” and then press the NEXT button.
The ALARM SET screen will be displayed.
ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF
Use the cursor button to select MOTION SENSOR “OFF”, press the setting buttons to change the setting to “ON”, and then press the NEXT button.
The motion sensor alarm setting screen will be displayed.
ALARM OFF ACTIVE REC. OFF MOTION SENSOR ON * VIDEO LOSS OFF
Press camera select button 5.
The image from camera 5 appears and T-1 flashes.
CAMERA NO.05 T-1 LEVEL:OFF MODE:A

ALARM SET SETTINGS
Use the cursor button to move the cursor to the middle of the screen, and then press the setting buttons so that “A” is displayed.
6 + –
If the camera image disappears because of a sudden accident or some other reason (so that image input stops), this sets whether the image that appeared immediately before the signal was lost is displayed as a still image or whether a test pattern is displayed. Example: To set a test pattern for the image
Set so that “A” is displayed in the middle of the screen.
when there is a VIDEO LOSS 1 Press the MENU button, use the cursor button to
select “ALARM SET” and then press the NEXT button.
The ALARM SET screen will be displayed.
press the setting buttons to select “T-2”.
Use the cursor button to select VIDEO LOSS “OFF”, and then use the setting buttons to change to “TEST”.
+ – 2
8 Use the cursor button to select LEVEL “OFF”, and
(ALARM SET)
then specify a sensitivity of “2” with the setting buttons.
ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS TEST
Display examples:
9 Use the cursor button to select “MODE”, and then
press the setting buttons to select “A”.
--

ALARM SET SETTINGS
Resetting an alarm
When images from the camera where the alarm was detected are appearing in a single-screen display
Press the camera select button for the camera that is being shown in the single-screen display.
The alarm will then be canceled.
When images from the camera where the alarm was detected are displayed in a multiple-screen
Press the camera select button for the camera that is showing the alarm.
The alarm images will appear in a single-screen display.
Press the camera select button again.
The alarm will then be canceled.


1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
You can set a security lock for the multiplexer to lock all button operations and menu operations in order to prevent mis-operations from being carried out when camera images are being displayed or video images are being played back.
This lets you set a 4-digit code number to use for locking menu screen settings. Example: To register code numbers 1, 2, 3, 4
Use the cursor button to select OPERATION “CODE 1111”, and then press camera select buttons 1, 2, 3 and 4.
The MAIN MENU screen will be displayed.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
OPERATION CODE 1111 LOCK OFF
(SEQURITY LOCK SET)
Use the cursor button to select “SECURITY SET” and then press the NEXT button.
code number.
The SECURITY LOCK SET screen will be displayed.
Use the cursor button to select OPERATION “LOCK OFF”, use the setting buttons to select “ON”, and then press the MENU button.
OPERATION CODE 1111 LOCK OFF
SETUP CODE 1111 LOCK OFF
The display will return to the camera image screen, and all button operations will be locked.
OPERATION CODE 1234 LOCK OFF
(SEQURITY LOCK SET)
OPERATION CODE 1234 LOCK ON

Use the camera select buttons to re-enter the code number (example: 1234) that was entered under OPERATION “CODE”.
Press any single button.
A buzzer will sound and the code number request message will appear.
The buzzer will sound, the lock will be canceled and the camera images will be displayed.
SECURITY CODE SECURITY CODE SECURITY CODE
SECURITY CODE SECURITY CODE ¤¤¤¤ ¤¤¤¤ SECURITY CODE ¤¤¤¤
number request message will disappear after 10 seconds.
This lets you set a 4-digit code number to use for locking menu screen settings. Example: To register code numbers 4, 3, 2, 1
Use the cursor button to select SETUP “CODE 1111”, and then press camera select buttons 4, 3, 2 and 1.
(SET UP)
A buzzer will sound and a code number request message will appear.
code number.
SECURITY CODE SECURITY CODE SECURITY CODE
number request message will disappear after 10 seconds.
Use the camera select buttons to re-enter the code number (example: 4321) that was entered under SETUP “CODE”.
Use the cursor button to select SETUP “LOCK OFF”, use the setting buttons to select “ON”, and then press the MENU button.
The buzzer will sound and the lock will be canceled.
The menu screen settings are now locked.
SECURITY CODE SECURITY CODE ¤¤¤¤ ¤¤¤¤ SECURITY CODE ¤¤¤¤
Notes common to SECURITY LOCK:


1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
Make dome-type camera settings to enable power and signal control with a RS-485 dedicated coaxial cable.
The following settings must be made if using the RS-232C connector or the RS-485 connector for serial communication between a computer or a system controller and the multiplexer.
+ – 4
Use the cursor button to select DATA SPEED “19200”, and then press the setting buttons to set the communication speed.
Settings for serial communication between the computer and system controller using RS-232C connectors and RS-485 connectors.
This sets the data communication speed for serial communication.
The MAIN MENU screen will be displayed.
(CONTROL SET)
DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
2400, 4800, 9600, 19200
Use the cursor button to select “CONTROL SET” and then press the NEXT button.
Use the cursor button to select ALARM SEND “ON”, and then press the setting buttons to select the alarm data.
The CONTROL SET screen will be displayed.
(CONTROL SET)
DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C
DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C
CAMERA CONTROL SANYO *
+ – 3
Use the cursor button to select RS232C/RS485 “RS232C”, and then press the setting buttons to select “RS232C” or “RS485”
DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C
Display examples:
This completes the settings.

CAMERA CONTROL setting
To control the dome-type camera
This describes the settings and methods of operation when connecting a dome-type camera for which the power and signal can be controlled through a coaxial cable to the camera video input connector. The two methods of operation are: direct control using the control buttons on this unit and operation from the system controller (using the RS-485 connector).
from the system controller through this unit.
Use the cursor button to select CAMERA CONTROL “SANYO”, and then press the NEXT button.
The CAMERA CONTROL SET screen will be displayed.
this unit
DATA SPEED 19200 ALARM SEND OFF RS232C/RS485 RS232C
Press the LIVE button.
To display will return to the normal screen.
Display examples:
Press the camera select button (example: 2) for the connected dome-type camera.
The main monitor or spot monitor will change to a single-screen display.
Use the cursor buttons to select “OFF” for the number of a dome-type camera that is connected (example: 01).
operations are not available for signal-screen display on the main monitor while the dome-type camera image is being viewed.
IN IN 01:OFF 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF
1 Cursor buttons: Enable pan and tilt operations 2 Setting buttons: Zoom in (+), zoom out (–) 3 Next screen button: Enables one-touch auto focus
Press the setting button and use the setting buttons once more to enter the address of the camera (example: 001).
While viewing, if you press and hold down the camera select button for about two seconds, the indicator will flash and the following camera adjustments will be enabled.
IN IN 01:001 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF
to make camera adjustments will be canceled after about ten seconds. For making adjustments, press the camera select button once more.
4 Cursor button (→): Open iris Cursor button (←): Close iris 5 Setting button (+): Manual focus Setting button (–): Manual focus
This completes the settings. Use the control buttons in the system controller “MULTIPLEXER” operating domain for controlling the dome-type cameras.

1 Camera number Shows the camera number where the alarm was detected. 2 DATE Shows the date that the alarm was detected. 3 TIME Shows the time of day that the alarm was detected. 4 ITEM E: Indicates that an external alarm was detected. S: Indicates that a motion sensor alarm was detected. V: Indicates that a video loss was detected.

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)
(ALARM DATA) 1/ 1 CAM DATE TIME ITEM 1 1 06-08 11:45 E 2 2 06-08 10:30 S 3 3 06-08 08:30 V
Alarm data can be displayed on the screen in the form of an alarm list. This can be used for purposes such as checking the alarm images that have been recorded by the recording device. Note: To display alarm information in the alarm list, you need to make the required ALARM settings (see page 62) and set “ALARM
LIST” to “ON”.
The MAIN MENU screen will be displayed.
1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)
Use the cursor button to select “ALARM DATA” and then press the NEXT button.
(ALARM DATA) 1/ 1 CAM DATE TIME ITEM 1 1 06-08 11:45 E 2 2 06-08 10:30 S 3 3 06-08 08:30 V
The ALARM DATA screen will be displayed.
To display the next page of the alarm list, press the NEXT button.
(ALARM DATA) 2/ 3 CAM DATE TIME ITEM 9 4 06-08 05:30 E 10 7 06-08 03:00 S 11 10 06-08 02:15 V
The next page of the alarm list will then be displayed. Note: If the number of alarm entries reaches 100, the oldest entries will be
deleted and the newer entries will be displayed.


Pin No. Signal Operation Signal direction 1 – – 2 RXD Receive data Computer → Multiplexer 3 TXD Transmit data Multiplexer → Computer 4 – – – 5 GND Ground – 6 – – – 7 RTS Request to send Multiplexer → Computer 8 – – – 9 – – –
5 4 3 2 1
9 8 7 6

Mode Asynchronous Character length 8 bits Data transmit speed 2400, 4800, 9600, 19200 bps Parity None Stop bit 1
Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a response from the multiplexer, and then transmits the next byte of data. To start sending commands, an ON (F6) command is sent. The multiplexer will continue to receive commands until an OFF (F7) command is sent to stop. The multiplexer sends an ACK (OA) each time it receives a command. See Table 4 - Command Table on page 79.

Pin No. Pin A signals Pin B signals 1 Spare Spare 2 Spare Spare 3 Signal B Signal A 4 Signal A Signal B 5 Spare Spare 6 Spare Spare
Mode Asynchronous Character length 8 bits Data transmit speed 2400, 4800, 9600, 19200 bps Parity None Stop bit 1
A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special controller be used. Contact the place of purchase for further details on obtaining a special controller.

If several multiplexers are being connected together, termination settings must also be made.

reflected by either end of the series and this will affect the transmission of other data, so that the data that is transmitted to each device will not be correct.
System controller · Termination switch · Time lapse VCR


Bit Bit details 3 Indicates the display channels and menu numbers for each display on the main monitor using 4 bits
(For serial connection) 2 0000: MAIN 1 0001: SUB 1 0 0010: SUB 2 0011: SUB 3 (Menu selection) 0001: Menu 1 MAIN MENU settings 0010: Menu 2 LANGUAGE settings 0011: Menu 3 CLOCK SET settings 0100: Menu 4 DISPLAY SET settings 0101: Menu 5 VCR SET settings 0110: Menu 6 ALARM SET settings 0111: Menu 7 SECURITY SET settings 1000: Menu 8 CONTROL SET settings 1001: Menu 9 ALARM DATA settings
When this command is sent by the computer, the multiplexer returns a 5-byte operating status code (Table 1).
STATUS SENSE (D7) bit allocation (Table 1)
The 4th and 5th bytes are spare. 1st byte
Bit Bit details 7 Indicates LIVE and VCR

(During single-screen) 2 0000: Channel 1 1 0001: Channel 2 0 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16* (During 4-screen) 0000: 4-screen (1, 2, 3, 4) 0001: 4-screen (5, 6, 7, 8) 0010: 4-screen (9, 10*, 11*, 12*) 0011: 4-screen (13*, 14*, 15*, 16*) (For multiple-screen) 0000: Single-screen 1000: 9-screen 1111: 16-screen* (For plus screen) 0000: Channel 1 0001: Channel 2 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*
4 Spare 0 3 Indicates the main monitor display status using 4 bits
0000: Normal display 2 0001: Automatic switching display 1 0010: Zoom display 0 0011: Still image 0100: Zoomed still image 0101: Still image zoomed 0110: Zoom position setting 0111: Still image zoom position setting
Bit Bit details 7 Indicates the currently- operating spot monitor using 2 bits
5 Spot monitor operation
4 Spot monitor operation
0000: Channel 1 2 0001: Channel 2 1 0010: Channel 3 0 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*
*: Command for MPX-CD163 only

4th byte

Bit Bit details 7 Indicates the model number using 1 bit.
Returned when the multiplexer receives a command. NAK (0B)
0000: Older series (CD16, CD162) 6 0001: X-CD163 series 5 4 3 Spare 2 Spot monitor operation
Returned when the multiplexer does not receive a command. ALARM (BF)
When there is alarm input, an ALARM command is sent as a header, and after this the alarm data (Table 3) is sent using 1 byte. Alarm data (Table 3)
1 Indicates the number of spot monitors using 2 bits

Bit Bit details 7 Indicates the type of alarm using 2 bits
Returns the multiplexer external alarm status (Table 2) using 6 bytes
0000: Channel 1 2 0001: Channel 2 1 0010: Channel 3 0 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*
1st byte
2nd byte

7 ALARM 8 ON 6 ALARM 7 ON 5 ALARM 6 ON 4 ALARM 5 ON 3 ALARM 4 ON 2 ALARM 3 ON 1 ALARM 2 ON 0 ALARM 1 ON
7 ALARM 16 ON* 6 ALARM 15 ON* 5 ALARM 14 ON* 4 ALARM 13 ON* 3 ALARM 12 ON* 2 ALARM 11 ON* 1 ALARM 10 ON* 0 ALARM 9 ON*
4th byte
*: Command for MPX-CD163 only

7 SENSOR 8 ON 6 SENSOR 7 ON 5 SENSOR 6 ON 4 SENSOR 5 ON 3 SENSOR 4 ON 2 SENSOR 3 ON 1 SENSOR 2 ON 0 SENSOR 1 ON
7 SENSOR 16 ON* 6 SENSOR 15 ON* 5 SENSOR 14 ON* 4 SENSOR 13 ON* 3 SENSOR 12 ON* 2 SENSOR 11 ON* 1 SENSOR 10 ON* 0 SENSOR 9 ON*
6th byte

7 VIDEO LOSS 8 ON 6 VIDEO LOSS 7 ON 5 VIDEO LOSS 6 ON 4 VIDEO LOSS 5 ON 3 VIDEO LOSS 4 ON 2 VIDEO LOSS 3 ON 1 VIDEO LOSS 2 ON 0 VIDEO LOSS 1 ON
7 VIDEO LOSS 16 ON* 6 VIDEO LOSS 15 ON* 5 VIDEO LOSS 14 ON* 4 VIDEO LOSS 13 ON* 3 VIDEO LOSS 12 ON* 2 VIDEO LOSS 11 ON* 1 VIDEO LOSS 10 ON* 0 VIDEO LOSS 9 ON*
*: Command for MPX-CD163 only

The following table shows all of the commands that can be processed by the multiplexer. If a command sent does not correspond to a multiplexer function, the command is received but no operation is carried out.

*: Command for MPX-CD163 only **: Command for RS-485 only

Camera video input connectors: VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 16 Control signal superimposed when camera operating
Camera video output connectors: Throughput of each input, 1.0 Vp-p/75 Ω, BNC connector x 16 (MPX-CD93: BNC connector x9)
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω, unbalanced • Digital input connector: RJ-45 x 1
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω, unbalanced • Digital input connector: RJ-45 x 1
Main monitor output connector (MAIN MONITOR): VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1
Camera live image or VCR playback image output: single-screen, automatic switching image, multiple-screen • S-Video output connector: Separate YC signals, DIN connector (S terminal) x 1
Spot monitor output connectors (SPOT MONITOR 1 - 4): VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 4
Automatic screen switching timing: Available in single-screen and quad mode, with interval selectable from 1 – 30 sec.

In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user’s expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service Centers may be obtained by calling the toll-free number listed below.
For product operation, authorized service center referral, service assistance or problem resolution, call
Weekdays 8:30 AM – 5:00 PM Pacific Time For accessories and/or parts, call
Weekdays 8:30 AM – 5:00 PM Pacific Time
THIS WARRANTY IS VALID ONLY ON SANYO PRODUCTS PURCHASED OR RENTED IN THE UNITED STATES OF AMERICA, EXCLUDING ALL U.S. TERRITORIES AND PROTECTORATES. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL RETAIL PURCHASER OR END-USER. THE ORIGINAL DATED BILL OF SALE, SALES SLIP OR RENTAL AGREEMENT MUST BE SUBMITTED TO THE AUTHORIZED SANYO SERVICE CENTER AT THE TIME WARRANTY SERVICE IS REQUESTED.
Subject to the OBLIGATIONS above and EXCLUSIONS below, SANYO Fisher Company warrants this SANYO product against defects in materials and workmanship for the periods specified below. SFC will repair or replace (at its option) the product and any of its parts which fail to conform to this warranty. The warranty period commences on the date the product was first purchased or rented at retail.
3 YEARS 3 YEARS
EXCLUSIONS
This warranty does not cover (A) the adjustment of customer-operated controls as explained in the appropriate model’s instruction manual, or (B) the repair of any product whose serial number has been altered, defaced or removed. This warranty shall not apply to the cabinet or cosmetic parts, batteries or routine maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product after repair. This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including, but not limited to, any malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear. The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any other obligation or liability. SFC DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED, WITH REGARD TO THIS PRODUCT (INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS). IN NO EVENT SHALL SFC BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE OWNERSHIP OR USE OF THIS PRODUCT OR FOR ANY DELAY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL. SFC’S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER, ARISING OUT OF OR IN CONNECTION WITH THE SALE, USE OR OWNERSHIP OF THIS PRODUCT INCLUDING WARRANTOR’S NEGLIGENCE, ALLEGED DAMAGED OR DEFECTIIVE GOODS, WHETHER SUCH DEFECTS ARE DISCOVERABLE OR LATENT, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
For your protection in the event of theft or loss of this product, please fill in the information below for you own personal records.
Model No Serial No (Located on back or bottom side of unit.)
Date of Purchase Purchase Price
Where Purchased

Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.