EN
Fisher logo
Official user manual

Fisher MPX-CD163

252 pages·8.5 MB·Network Card·PDF·ENDEITNLJA
Fisher MPX-CD163
Table of Contents 80 sections MPX-CD163 MPX-CD93 · INSTRUCTION MANUAL MANUEL D’INSTRUCTIONS MANUAL DE INSTRUCCIONES · PRECAUTION · Declaration of Conformity · … ShowHide
MPX-CD163 MPX-CD93p.1INSTRUCTION MANUAL MANUEL D’INSTRUCTIONS MANUAL DE INSTRUCCIONESp.1PRECAUTIONp.2Declaration of Conformityp.2CAUTIONp.2RISK OF ELECTRIC SHOCKp.2DO NOT OPENp.2Locationp.2For the customers in Canadap.2SERVICEp.2MAIN FEATURESp.5ACCESSORIESp.5PART NAMESp.6Frontp.69 Video playback button and indicator (VCR)p.7L Setting buttons (+, –)p.7F Automatic camera switching button and indicatorp.7M Cursor buttonsp.7G Still image button and indicator (STILL)p.7H Electronic zoom button and indicator (ZOOM)p.7N Menu reset/Clock adjust button (MENU RESET)p.7I Menu button and indicator (MENU)p.7J Next screen button and indicator (NEXT)p.7K Cancel/display button and indicator (BACK)p.7Rearp.8Basic connections (MPX-CD163 model)p.9CONNECTIONSp.10Digital connectionsp.10A Digitally connecting four multiplexersp.10B Digitally connecting the multiplexer and a digital video recorderp.11System control connectionsp.12Computer controlp.12External alarm sensor setupp.13Using as a monitor board during a motion sensor alarmp.13Connecting a remote control circuitp.13MONITORING FUNCTIONSp.14Viewing camera images (See page 15.)p.14Viewing recorded images (See page 23.)p.14N Viewing a single-screen image (See page 15.)p.14ZOOMp.14STILLp.14N Viewing multiple-screen images (See page 18.)p.14Alarm functionp.15Recording functionp.15VCRp.15Timer functionp.15VIEWING CAMERA IMAGESp.16Viewing a single-screen imagep.16LIVEp.16Setting the camera image to single-screen displayp.16Pausing imagesp.16STILL 2p.16STILL STILL ZOOMp.16ZOOM 2p.17Viewing multiple-screen imagesp.19Viewing images as 9-screen or 16-screen displaysp.19MULTIp.19Viewing images as a 4-screen displayp.19Plus screen viewingp.20PLUS 1p.20MULTI 2p.20Viewing automatically switching imagesp.21Automatically switching of the single-screen imagesp.21SEQUENCE 2p.21SEQUENCE 3p.21Automatically switching of the 4-screen imagesp.22Automatically switching of the plus screen imagep.22Displaying and automatically switching recorded images in the plus screenp.23VCR 2p.23SEQUENCE 4p.23VIEWING RECORDED IMAGESp.24Playing back recorded images in a single-screen displayp.24Playing back in a single-screenp.24Pausing recorded imagesp.24ZOOM 6p.25Playing back multiple-screen displaysp.26Playing back images as 9-screen or 16-screen displaysp.26Playing back images as a 4-screen displayp.26Playing back images as 13-screen or 6-screen displays (plus screen)p.27Playing back automatically switching imagesp.28
Page 1 of the Fisher MPX-CD163 user manual — MPX-CD163 MPX-CD93
Page 1 · click to enlarge
Page 1

MPX-CD163 MPX-CD93

INSTRUCTION MANUAL MANUEL D’INSTRUCTIONS MANUAL DE INSTRUCCIONES

Fisher MPX-CD163 — MPX-CD163 MPX-CD93 diagram (page 1)
Fig. 1
Page 2 of the Fisher MPX-CD163 user manual — SERVICE
Page 2 · click to enlarge
Page 2

PRECAUTION

Declaration of Conformity

CAUTION

Model Number : MPX-CD163/ MPX-CD93 Trade Name : SANYO Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 Telephone No. : (818) 998-7322 • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,

RISK OF ELECTRIC SHOCK

DO NOT OPEN

and (2) this device must accept any interference

received, including interference that may cause undesired operation.

Location

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

  • For safe operation and satisfactory performance of your unit, keep the following in mind when selecting a place for its installation:
  • Shield it from direct sunlight and keep it away from sources of intense heat.
  • Avoid dusty or humid places.
  • Avoid places with insufficient ventilation for proper heat dissipation. Do not block the ventilation holes at the top and bottom of the unit. Do not place the unit on a carpet because this will block the ventilation holes.
  • Install the unit in a horizontal position only.
  • Avoid locations subject to strong vibrations.
  • Avoid moving the unit between cold and hot locations.
  • Do not place the unit directly on top of a monitor TV, as this may cause playback or recording problems.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

  • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generated, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Avoiding Electrical Shock and Fire
  • Do not handle the power cord with wet hands.
  • Do not pull on the power cord when disconnecting it from an AC wall outlet. Grasp it by the plug.
  • If any liquid is spilled on the unit, unplug the power cord immediately and have the unit inspected at a factory-authorised service centre.
  • Do not place anything directly on top of this unit.

For the customers in Canada

This class B digital apparatus complies with Canadian ICES-003.

SERVICE

This unit is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre.

Page 3 of the Fisher MPX-CD163 user manual — PRECAUTION
Page 3 · click to enlarge
Page 3
Page 3 of the Fisher MPX-CD163 user manual — PRECAUTION
Page 4 of the Fisher MPX-CD163 user manual — PRECAUTION
Page 4 · click to enlarge
Page 4
Page 4 of the Fisher MPX-CD163 user manual — PRECAUTION
Page 5 of the Fisher MPX-CD163 user manual — MAIN FEATURES
Page 5 · click to enlarge
Page 5

MAIN FEATURES

ACCESSORIES

  • This multiplexer can display images that are being recorded by a camera in a split-screen (16, 9, 4), and it can also display images that have already been recorded in a split-screen. The MPX-CD93 model split-screen display is capable of 4-screen or 9-screen displays only.
  • High-speed switching for each field at maximum speed
  • Single-screen, 4-screen, 9-screen and 16-screen display, camera images and video playback images can be displayed in the lower-right corner of the screen, and automatic switching is also possible.
  • Multiple multiplexers can be connected together to create an expanded system for centralized monitoring.
  • A single-screen can be displayed during spot monitoring and the alarm screen can be displayed when an alarm occurs.
  • Timer setting allows the following settings to be made for each camera.

Fixer Power cord tie x1

– Program recording lets images from a specified camera

be recorded during four different daily time zones. – Automatic switching of camera images selected by timer

period – Setting of automatic screen switching speed for each

  • camera for four different daily time zones.
  • A monitor masking function hides the images for specified cameras with gray patterns so that they cannot be monitored.
  • Motion sensor detection is possible for each camera. Moving objects can be given recording priority and alarm operation is possible.
  • If a signal loss is detected, the monitor screen image can be replaced by a test pattern or a still image, even if the camera image has been lost as a result of the interruption.
  • Cameras that can be controlled via coaxial cables can be connected to allow operation of these cameras from the multiplexer.
  • Computer control via an RS-232C interface is possible.
  • Connection to a system controller (sold separately) is possible using an RS-485 (RJ-11) interface.
  • Equipped with four spot monitor outputs and S-Video signal input and output connectors.
  • Menu screens allow the display of up to 100 alarm recording items.
  • Connection to digital equipment such as a digital video recorder (sold separately) is possible using digital connectors.

Power cord x1

Page 6 of the Fisher MPX-CD163 user manual — PART NAMES
Page 6 · click to enlarge
Page 6

PART NAMES

Front

Fisher MPX-CD163 — PART NAMES diagram (page 6)
Fig. 2
Page 7 of the Fisher MPX-CD163 user manual — K Cancel/display button and indicator (BACK)
Page 7 · click to enlarge
Page 7

PART NAMES

Fisher MPX-CD163 — PART NAMES diagram (page 7)
Fig. 3

9 Video playback button and indicator (VCR)

L Setting buttons (+, –)

  • These buttons are used to change the setting values in the menu screens (setting screens).
  • If a coaxial cable camera (such as a dome-type camera) is connected, these buttons can be used to carry out zoom operation. Furthermore, if these buttons are pressed after a camera select button, manual focus adjustment is possible. They can also be used to adjust the playback speed when recorded images from a digital video recorder are being played back.

Press this button to play back recorded images. The indicator will illuminate and the video playback images will appear on the monitor.

F Automatic camera switching button and indicator

(SEQUENCE) This button is used to automatically change the camera image appearing in the single-screen, 4-screen or quarter screen (plus screen) display. When the SEQUENCE button is pressed, the indicator flashes and the screen changes automatically. The camera indicator also changes to match the images on the screen.

M Cursor buttons

  • These buttons can be used to select items while a menu screen (setting screen) is displayed.
  • If a camera that can be controlled via a coaxial cable (such as a dome-type camera) is connected, these buttons can be used to carry out pan and tilt operations.
  • They can also be used to carry out playback, stop, pause and reverse operations when recorded images from a digital video recorder are being played back.

G Still image button and indicator (STILL)

If this button is pressed while monitoring is being carried out using the single-screen display, the indicator will flash and the image will be paused. If the button is pressed once more, the image returns to normal.

H Electronic zoom button and indicator (ZOOM)

N Menu reset/Clock adjust button (MENU RESET)

If monitoring is being carried out using the single-screen display, the image can be enlarged by 2x. When this button is pressed, the indicator will flash and the 2x zoom screen will be displayed.

If this button is pressed while a menu screen (setting screen) is displayed, the settings in the currently-displayed menu screen are reset to their default values. If this button is pressed while monitoring camera images, the clock is adjusted and the minutes and seconds are reset to 00.

I Menu button and indicator (MENU)

This button is used to display the menu screen.

J Next screen button and indicator (NEXT)

  • If this button is pressed while a menu screen is displayed, a sub-menu setting screen is displayed.
  • If a camera that can be controlled via a coaxial cable (such as a dome-type camera) is connected, this button can be used for one-touch focus adjustment. Playback of recorded images from multiple digital video recorders is carried out by selecting the images at the digital video recorders.

K Cancel/display button and indicator (BACK)

  • If this button is pressed while a sub-menu screen is displayed, the screen returns to the previous level menu screen.
  • If this button is pressed while monitoring camera images, the on-screen displays (such as titles) can be turned on and off.
Page 8 of the Fisher MPX-CD163 user manual — PART NAMES
Page 8 · click to enlarge
Page 8

PART NAMES

Rear

Fisher MPX-CD163 — PART NAMES diagram (page 8)
Fig. 4

IN 1 2 3 4 5 6 7 9 8

4 5 6 7 9 10 11 12 13 14 15 16 8

1 2 3 4 5 6 7 8 9 10

3 4 SPOT MONITOR MAIN MONITOR MAIN MONITOR IN IN OUT

SENSOR ALARM OUT RS485 DIGITAL SPOT MONITOR MAIN MONITOR MAIN MONITOR

Page 9 of the Fisher MPX-CD163 user manual — Basic connections (MPX-CD163 model)
Page 9 · click to enlarge
Page 9

CONNECTIONS Turn off the power for all components before connecting them.

Be sure to carefully read the Instruction Manual for all equipment being connected to the multiplexer. If the connections are incorrect, smoke or operating malfunctions may result.

Basic connections (MPX-CD163 model)

Nine cameras can be connected to the MPX-CD93 model.

Fisher MPX-CD163 — Basic connections (MPX-CD163 model) diagram (page 9)
Fig. 5 · Basic connections (MPX-CD163 model)

Switch output connector Time lapse VCR (sold separately)

Fisher MPX-CD163 — Basic connections (MPX-CD163 model) diagram (page 9)
Fig. 6 · Basic connections (MPX-CD163 model)
Page 10 of the Fisher MPX-CD163 user manual — A Digitally connecting four multiplexers
Page 10 · click to enlarge
Page 10

CONNECTIONS

Digital connections

A Digitally connecting four multiplexers

Up to four of these units can be connected for monitoring. By connecting several units, up to 64 cameras can be viewed with one main monitor. Also, by connecting a recorder to each multiplexer, playback of recorded images can be viewed on the main monitor. * For the MPX-CD93 model, the total number of cameras that can be viewed with one monitor is 36, nine to each unit. Use straight-type CAT-5 RS485 cables (sold separately) to connect the DIGITAL IN connectors to the digital output connectors of other devices. Use cables with a length of 3 m or less.

1 2 3 4 23 5678 9101112 13 14 15 161415
Fisher MPX-CD163 — A Digitally connecting four multiplexers diagram (page 10)
Fig. 7 · A Digitally connecting four multiplexers
  • Main unit and sub-units must be specified. Distinguishing a main unit and sub-units enables the main unit to display the camera images of a sub-unit on the monitor. (See page 50.)
  • Since no video signal is output from the main monitor output connector on the rear panel of a sub-unit, if a monitor is connected the screen will be black.
  • If these connections have been made, a digital video recorder cannot be connected digitally.
Page 11 of the Fisher MPX-CD163 user manual — B Digitally connecting the multiplexer and a digital video recorder
Page 11 · click to enlarge
Page 11

CONNECTIONS

B Digitally connecting the multiplexer and a digital video recorder

This unit and a digital video recorder can be connected digitally to provide high-resolution playback of recorded images. Use straight-type CAT-5 RS485 cables (sold separately) to connect the DIGITAL IN connectors to the digital output connectors of other devices. Use cables with a length of 3 m or less.

Fisher MPX-CD163 — B Digitally connecting the multiplexer and a digital video recorder diagram (page 11)
Fig. 8 · B Digitally connecting the multiplexer and a digital…
1 2 3 4 5 6 7 8 9 10 11 12 3 14 15 16 1 23 5 67 9 1011 3 1415

Digital video recorder (sold separately)

Page 12 of the Fisher MPX-CD163 user manual — Computer control
Page 12 · click to enlarge
Page 12

CONNECTIONS

System control connections

Use the RS485 connector or the CONTROL connector to connect a system controller to the multiplexer. After connecting the system controller, you will need to carry out the settings that are given in the CONTROL SET menu. (See page 72.)

A When using the RS485 (RJ-11) connector Connect modular cables (sold separately) to the RS485 control connectors at the rear of the multiplexer.

To other connector A

To other connector A

  • If using a straight-type cable Connect connector A to connector A and connector B to connector B.
  • If using a cross-type cable Connect connector A to connector B and connector B to connector A.

Straight-type cable Cross-type cable

Straight type Cross type

1Spare11 Spare Spare Spare 2 3 42 3 41 6 1 62 3 4 Spare 5 6Spare5 6

B When using the CONTROL connector (A/B) Connect a twisted-pair cable (sold separately) to the A, B and C (ground) terminals of the CONTROL connector at the rear of the multiplexer. Connect signal A to signal A and signal B to signal B.

Push the cable in.

Ground To signal A

Computer control

When connecting the multiplexer to a computer (sold separately), use a D-Sub 9-pin cable (sold separately) to connect the RS-232C connector to the computer. After connecting, you will need to carry out the settings that are given in the CONTROL SET menu. (See page 72.)

Fisher MPX-CD163 — Computer control diagram (page 12)
Fig. 9 · Computer control

Twisted-pair cable · To signal B · Computer

Page 13 of the Fisher MPX-CD163 user manual — Connecting a remote control circuit
Page 13 · click to enlarge
Page 13

CONNECTIONS

External alarm sensor setup

Using as a monitor board during a motion sensor alarm

In order to make an external alarm sensor operate, an external switch must be connected to an ALARM IN connector. When an intruder activates the external switch (such as by opening a door), an alarm signal is received and an alarm can be made to sound. The MPX-CD93 model uses the connectors marked *.

When the motion sensor built into the multiplexer responds to an alarm, it outputs an alarm signal to the SENSOR ALARM OUT connector. If a switching circuit such as a warning lamp is connected to this connector, the warning lamp will illuminate when there is a response from the motion sensor. If the warning lamp is fixed somewhere in the layout diagram for an area such as a factory, the location of the camera can be ascertained in an instant during an emergency. The connector is always open. The pin corresponding to the number of the camera that generates a sensor response switches to Low.

Fisher MPX-CD163 — CONNECTIONS diagram (page 13)
Fig. 10

1K 25mA 25V 40mW

Rated values for each connector (at 25˚C)

  • Max. current
  • Max. voltage
  • Max. power

Connecting a remote control circuit

If a remote control circuit is constructed as shown in the illustration and connected to the remote control input (R1 and R2) terminals of the CONTROL connector, the multiplexer can be operated by remote control. (Contact LOW input) The MPX-CD93 model can control up to nine cameras.

Fisher MPX-CD163 — Connecting a remote control circuit diagram (page 13)
Fig. 11 · Connecting a remote control circuit

The remote control cable should be no more than 5 m long. Note:

Page 14 of the Fisher MPX-CD163 user manual — ZOOM
Page 14 · click to enlarge
Page 14

MONITORING FUNCTIONS

Following is a summary of the operations that can be carried out while monitoring camera images. Refer to the corresponding page numbers for more detailed explanations.

Viewing camera images (See page 15.)

Viewing recorded images (See page 23.)

The following operations can be carried out while monitoring camera images and when playing back images that have been recorded.

N Viewing a single-screen image (See page 15.)

ZOOM

STILL

N Viewing multiple-screen images (See page 18.)

For the MPX-CD93 model, a 9-screen display will appear. N Viewing automatically switching images (See page 20.)

Zoom · Single-screen · Still image

Page 15 of the Fisher MPX-CD163 user manual — Timer function
Page 15 · click to enlarge
Page 15

MONITORING FUNCTIONS

Alarm function

Suspicious people can be detected while monitoring by using the alarm setting function. (See page 60.)

Fisher MPX-CD163 — MONITORING FUNCTIONS diagram (page 15)
Fig. 12

Signal loss detection alarm (See page 68.) Motion sensor alarm (See page 67.)

Recording function

A video recording device can be used to record camera images and alarm images taken during monitoring.

Program recording (See page 56.) Active recording (See page 64.)

Fisher MPX-CD163 — Recording function diagram (page 15)
Fig. 13 · Recording function

VCR

Records camera images Recording priority is given to alarm images.

Timer function

By using the timer function, a single day can be divided into four different time and each camera can be operated separately during each time zone.

Fisher MPX-CD163 — Timer function diagram (page 15)
Fig. 14 · Timer function

6:00 – 11:00 11:00 – 13:00 13:00 – 18:00 18:00 – 6:00

Images from cameras 1, 3, 5 and 6 are switched automatically

Images from cameras 8, 9, 10 and 16 are switched automatically

Images from cameras 7, 11, 12 and 13 are switched automatically

Images from cameras 4, 6, 9, 12 and 16 are switched automatically

Automatic switching display and recording of different camera images can be specified for each time zone. Furthermore, if sensor alarms are set, intruders can be detected during those time zones.

  • Timer setting (See page 36.)
  • Using the timer function for automatic switching display (See page 45.)
  • Using the timer function to record images (See page 58.)
  • Using the timer function to detect motion alarms (See page 67.)
  • Using the timer function to cover the camera image with a gray pattern (See page 48.)

Monitor

Page 16 of the Fisher MPX-CD163 user manual — STILL STILL ZOOM
Page 16 · click to enlarge
Page 16

VIEWING CAMERA IMAGES

Viewing a single-screen image

Press the LIVE button.

The camera image appears as a split-screen.

LIVE

Setting the camera image to single-screen display

Fisher MPX-CD163 — LIVE diagram (page 16)
Fig. 15

Pausing images

Fisher MPX-CD163 — Pausing images diagram (page 16)
Fig. 16 · Pausing images

STILL 2

To cancel the still image, press the STILL button once more.

Pausing will be canceled and normal images will appear. Note: If you press the ZOOM button while the image is paused, the still image

will be enlarged. To return to the original still image, press the ZOOM button once more.

STILL STILL ZOOM

Page 17 of the Fisher MPX-CD163 user manual — ZOOM 2
Page 17 · click to enlarge
Page 17

VIEWING CAMERA IMAGES

Fisher MPX-CD163 — VIEWING CAMERA IMAGES diagram (page 17)
Fig. 17

The images will be enlarged. Note: If you set a zoom frame, the area of the image inside the zoom frame will

If you press the camera select button while zooming, the image will be easier to see due to the movement of the subject. The following changes will occur if you press the camera select button repeatedly.

  • An image with little movement (almost a still image) Large subjects become clearer and moving subjects appear a little rough.
  • An image with large movement (normal viewing) The image of a moving subject becomes clearer and subjects with little movement appear a little rough.
Fisher MPX-CD163 — VIEWING CAMERA IMAGES diagram (page 17)
Fig. 18

To return an enlarged image to normal image display, press the ZOOM button once more.

ZOOM 2

The zoom will be canceled and normal images will appear.

Image with large

Page 18 of the Fisher MPX-CD163 user manual — ZOOM 2
Page 18 · click to enlarge
Page 18

VIEWING CAMERA IMAGES

ExampleTo zoom in on the camera 2 image and move the zoom frame

You can select the zoom position by means of the zoom frame which appears on the screen. The position of the zoom frame is initially set to the middle of the screen.

Press camera select button 2.

The camera 2 image will appear in a single-screen display.

Press the ZOOM button.

The images will be enlarged.

ZOOM 2

Press and hold camera select button 2 for about 3 seconds or more.

The zoom will be canceled and the normal image will appear, and the zoom frame (G) will appear on the screen. Note: If the zoom frame remains on the screen for about 10 seconds without

being adjusted, the screen will return to zoom display. To make the zoom frame reappear, press and hold camera select button 2 again for 3 seconds or more.

Press the cursor button to move the zoom frame to the position you wish to enlarge.

Press camera select button 2 once more.

The image in the repositioned zoom frame will be enlarged. Note: If you press the STILL button while the images are being zoomed, an

enlarged still image will be displayed.

To return an enlarged image to normal image display, press the ZOOM button once more.

The zoom will be canceled and normal images will appear.

Page 19 of the Fisher MPX-CD163 user manual — Viewing images as a 4-screen display
Page 19 · click to enlarge
Page 19

VIEWING CAMERA IMAGES

Viewing multiple-screen images

Images from the cameras that are connected to the multiplexer can be displayed in several split-screen formats. Furthermore, the images from each camera can be displayed in any position within the split screen. (See page 41.)

Press the LIVE button.

LIVE

Viewing images as 9-screen or 16-screen displays

Press the MULTI button.

The display switches between 9-screen and 16-screen displays each time the MULTI button is pressed. To return to a single-screen display, press a camera select button.

MULTI

For the MPX-CD93 model, only the 9-screen display is available with no switching.

Viewing images as a 4-screen display

Press the QUAD button.

Images appear as a 4-screen display.

Press the QUAD button once more.

Camera images are switched in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16) each time the button is pressed. To return to a single-screen display, press a camera select button.

For the MPX-CD93 model, a 4-screen display of images from cameras 1 – 4, 5 – 8, or 9 – 3 will appear each time the button is pressed.

Page 20 of the Fisher MPX-CD163 user manual — MULTI 2
Page 20 · click to enlarge
Page 20

VIEWING CAMERA IMAGES

Plus screen viewing

The plus screen allows you to display the image from each camera as a quarter-screen picture in the lower right corner of the split-screen display, and images being recorded or played back can be monitored.

Press the PLUS button.

PLUS 1

The display changes to show a 13-screen display with a plus screen as a quarter-screen picture in the lower-right corner.

For the MPX-CD93 model, a 6-screen display appears.

MULTI 2

Press the MULTI button.

The display switches between 13-screen and 6-screen each time the MULTI button is pressed.

Press a camera select button (example: 12).

The images from the selected camera will be displayed in the plus screen. To cancel the plus screen, press the PLUS button once more.

For the MPX-CD93 model, press a camera select button numbered 9 or less.

Plus screen

Page 21 of the Fisher MPX-CD163 user manual — SEQUENCE 3
Page 21 · click to enlarge
Page 21

VIEWING CAMERA IMAGES

Viewing automatically switching images

The camera images are switched automatically in the order that has been set using the SEQUENCE settings. (See page 43.)

Press the LIVE button.

LIVE

Automatically switching of the single-screen images

Fisher MPX-CD163 — LIVE diagram (page 21)
Fig. 19

Press the camera select buttons (example: 1, 5, 7) to select the camera numbers for automatic switching.

The camera select buttons for the cameras that were selected are stored in memory. The indicator lamp will light up when the next button is pressed.

Press the SEQUENCE button.

SEQUENCE 2

Camera images will be switched automatically in the order 1, 5 and 7.

To cancel automatic switching, press the SEQUENCE button.

SEQUENCE 3

Automatic switching will be canceled and normal images will appear.

Page 22 of the Fisher MPX-CD163 user manual — SEQUENCE 3
Page 22 · click to enlarge
Page 22

VIEWING CAMERA IMAGES

Automatically switching of the 4-screen images

Fisher MPX-CD163 — Automatically switching of the 4-screen images diagram (page 22)
Fig. 20 · Automatically switching of the 4-screen images

Press the SEQUENCE button.

Camera images will be switched automatically in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16). For the MPX-CD93 model, images from cameras 1 – 4, 5 – 8, or 9 – 3 will be switched automatically.

SEQUENCE 2

Press the SEQUENCE button once more to return to the 4-screen display.

SEQUENCE 3

Automatic switching will be canceled and 4-screen display will be restored.

Automatically switching of the plus screen image

Fisher MPX-CD163 — Automatically switching of the plus screen image diagram (page 22)
Fig. 21 · Automatically switching of the plus screen image

Press the SEQUENCE button.

SEQUENCE 2

The camera images in the plus screen will be switched automatically.

Press the SEQUENCE button once more to return to the plus screen.

SEQUENCE 3

Automatic switching will be canceled and the plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Page 23 of the Fisher MPX-CD163 user manual — SEQUENCE 4
Page 23 · click to enlarge
Page 23

VIEWING CAMERA IMAGES

Displaying and automatically switching recorded images in the plus screen

Set the recording device to playback mode.

Press the PLUS button.

The plus screen is displayed.

PLUS 1

Press the VCR button.

This sets the plus screen to video playback mode.

VCR 2

Press the SEQUENCE button.

SEQUENCE 3

The playback images in the plus screen will be switched automatically.

Press the SEQUENCE button once more to return to the plus screen.

SEQUENCE 4

Automatic switching will be canceled and the plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Page 24 of the Fisher MPX-CD163 user manual — ZOOM 2
Page 24 · click to enlarge
Page 24

VIEWING RECORDED IMAGES

Playing back recorded images in a single-screen display

Press the VCR button to playback from the connected recorder.

VCR

through this unit, it will not be displayed correctly. “NO ID” will appear on the screen.

Playing back in a single-screen

Fisher MPX-CD163 — Playing back in a single-screen diagram (page 24)
Fig. 22 · Playing back in a single-screen

The recorded images will be played back in a single-screen.

Pausing recorded images

Fisher MPX-CD163 — Pausing recorded images diagram (page 24)
Fig. 23 · Pausing recorded images

To return a still image to normal image display, press the STILL button once more.

STILL 2

Pausing will be canceled and normal images will appear. Note: If you press the ZOOM button while an image is paused, the still image

will be enlarged. To return to the original still image, press the ZOOM button once more.

Fisher MPX-CD163 — STILL 2 diagram (page 24)
Fig. 24

The images will be enlarged. Note: If you set a zoom frame, the area of the image inside the zoom frame will

To return an enlarged image to normal image display, press the ZOOM button once more.

ZOOM 2

The zoom will be canceled and normal images will appear.

Page 25 of the Fisher MPX-CD163 user manual — ZOOM 6
Page 25 · click to enlarge
Page 25

VIEWING RECORDED IMAGES

ExampleTo zoom in on a specific part of the camera 2 image

You can use the zoom frame that appears on the screen to select the position you wish to enlarge. The zoom frame is set initially at the center of the screen.

Press camera select button 2.

Fisher MPX-CD163 — VIEWING RECORDED IMAGES diagram (page 25)
Fig. 25

The camera 2 image will appear in a single-screen display.

Press the ZOOM button.

The images will be enlarged.

ZOOM 2

Press and hold camera select button 2 for about 3 seconds or more.

The zoom will be canceled and the normal image will appear, and the zoom frame (G) will appear on the screen. Note: If the zoom frame remains on the screen for about 10 seconds without

being adjusted, the screen will return to zoom display. To make the zoom frame reappear, press and hold camera select button 2 again for 3 seconds or more.

Press the cursor button to determine the position you wish to enlarge.

Fisher MPX-CD163 — ZOOM 2 diagram (page 25)
Fig. 26

Press camera select button 2 one more.

The area of the image inside the zoom frame will be enlarged. Note: If you press the STILL button while the images are being zoomed, an

enlarged still image will be displayed.

Press the ZOOM button once more to return the enlarged image to the normal image.

ZOOM 6

The zoom will be canceled and normal images will appear.

Page 26 of the Fisher MPX-CD163 user manual — Playing back images as a 4-screen display
Page 26 · click to enlarge
Page 26

VIEWING RECORDED IMAGES

Playing back multiple-screen displays

Recorded images can be displayed in several split-screen formats. Furthermore, the images from each camera can be displayed in any position within the split-screen. (See page 41.)

Press the VCR button.

VCR

Playing back images as 9-screen or 16-screen displays

Press the MULTI button.

The display switches between 9-screen and 16-screen each time the MULTI button is pressed. To return to a single-screen display, press a camera select button.

For the MPX-CD93 model, only the 9-screen display is available with no switching.

Playing back images as a 4-screen display

Press the QUAD button.

Images appear as a 4-screen display.

Press the QUAD button once more.

Camera images are switched in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16) each time the button is pressed. To return to a single-screen display, press a camera select button.

For the MPX-CD93 model, a 4-screen display of images from cameras 1 – 4, 5 – 8, or 9 – 3 will appear each time the button is pressed.

Page 27 of the Fisher MPX-CD163 user manual — MULTI 2
Page 27 · click to enlarge
Page 27

VIEWING RECORDED IMAGES

Playing back images as 13-screen or 6-screen displays (plus screen)

Fisher MPX-CD163 — Playing back images as 13-screen or 6-screen displays (plus screen) diagram (page 27)
Fig. 27 · Playing back images as 13-screen or 6-screen display…

The display changes to show a 13-screen or 6-screen display with a plus screen as a quarter-screen picture in the lower-right corner.

Press the MULTI button.

The display switches between 13-screen and 6-screen each time the MULTI button is pressed.

MULTI 2

For the MPX-CD93 model, only the 6-screen display is available with no switching.

Press a camera select button (example: 12).

The playing back images from the selected camera will be displayed in the plus screen. To cancel the plus screen, press the PLUS button once more.

For the MPX-CD93 model, press camera select button 9.

Plus screen

Page 28 of the Fisher MPX-CD163 user manual — SEQUENCE 3
Page 28 · click to enlarge
Page 28

VIEWING RECORDED IMAGES

Playing back automatically switching images

Recorded images are switched automatically in the order that has been set using the SEQUENCE settings. (See page 43.)

Press the VCR button.

VCR

Automatic switching of the single-screen playback images

Fisher MPX-CD163 — VCR diagram (page 28)
Fig. 28

Press the camera select buttons (example: 1, 5, 7).

Press the SEQUENCE button.

SEQUENCE 2

The recorded images are automatically switched in the order set.

To cancel automatic switching, press the SEQUENCE button once more.

SEQUENCE 3

Automatic switching will be canceled and normal images will appear.

Page 29 of the Fisher MPX-CD163 user manual — SEQUENCE 3
Page 29 · click to enlarge
Page 29

VIEWING RECORDED IMAGES

Automatically switching of the 4-screen playback images

Fisher MPX-CD163 — Automatically switching of the 4-screen playback images diagram (page 29)
Fig. 29 · Automatically switching of the 4-screen playback ima…

Press the SEQUENCE button.

Camera images will be switched automatically in 4-screen display units (1 – 4, 5 – 8, 9 – 12, 13 – 16).

SEQUENCE 2

For the MPX-CD93 model, images from cameras 1 – 4, 5 – 8, or 9 – 3 will be switched automatically.

To cancel automatic switching, press the SEQUENCE button once more.

SEQUENCE 3

Automatic switching will be canceled and a 4-screen display will appear.

Automatically switching of the plus screen playback image

Fisher MPX-CD163 — Automatically switching of the plus screen playback image diagram (page 29)
Fig. 30 · Automatically switching of the plus screen playback…

Press the SEQUENCE button.

SEQUENCE 2

The playback images in the plus screen will be switched automatically.

To cancel automatic switching, press the SEQUENCE button once more.

SEQUENCE 3

Automatic switching will be canceled and a plus screen will appear. To cancel the plus screen, press the PLUS button once more.

Page 30 of the Fisher MPX-CD163 user manual — Spot Monitor Button Functions
Page 30 · click to enlarge
Page 30

VIEWING WITH SPOT MONITOR

Four monitors can be connected to the spot monitor output connectors on the rear panel of this unit. Even while the main monitor is showing camera images as split screens or playback, the camera images can be displayed on the spot monitors as single-screen or automatic switching images.

Fisher MPX-CD163 — VIEWING WITH SPOT MONITOR diagram (page 30)
Fig. 31

Spot Monitor Button Functions

When the SPOT MON. button is pressed in camera image (LIVE) or playback (VCR) mode, each spot monitor goes into selection standby condition. If the SPOT MON. button is pressed once more, LIVE or VCR mode is enabled.

  • Selection of spot monitor 1
  • Selection of spot monitor 2
  • Selection of spot monitor 3
  • Selection of spot monitor 4
Page 31 of the Fisher MPX-CD163 user manual — VIEWING WITH SPOT MONITOR
Page 31 · click to enlarge
Page 31

VIEWING WITH SPOT MONITOR

Spot monitor settings

SPOT MON. 1

Press the SPOT MON. button.

Camera select buttons 1 to 4 flash and spot monitor selection standby condition is enabled. Note:

  • If a button from 1 to 4 is pressed while the indicators are flashing, the spot monitor corresponding to the number of the button pressed will be selected.
  • If MAIN → SPOT1 on the DISPLAY SET menu are ON, the spot monitor 1 image will be the same as the main monitor screen.
Fisher MPX-CD163 — VIEWING WITH SPOT MONITOR diagram (page 31)
Fig. 32

Spot monitor indicator 4 and the SPOT MON. indicator will flash and S4 will appear (flashing) on the screen of spot monitor 4. Note: S1 to S4 will appear flashing on the

screen of each selected spot monitor.

Page 32 of the Fisher MPX-CD163 user manual — CAMERA CONTROL SANYO *
Page 32 · click to enlarge
Page 32

MENU FLOWCHART AND MENU OPERATIONS

Menu flowchart

(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

(LANGUAGE)

(CLOCK SET)

(DAY LIGHT SET)

01-01-2001 MON 00:00:00

WEEK MON TIME ON 1ST-SUN 04 02:00 OFF LST-SUN 10 02:00

FRANCAIS

TIMER ON ¤ DAY LIGHT ON ¤

ESPANOL

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN CHANGE¤ SEQUENCE INDIV.¤ MASK ON ¤ MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

CAMERA NO.01 01

(POSITION SET)

QUAD

01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16

(MAIN MENU)

(VCR SET)

(PROGRAM REC.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

PROGRAM REC. ONLY *

(SEQUENCE SET)

MAIN MONITOR 1 S ¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S

(ALARM OPERATION SET)

(ALARM SET)

ALARM EXT.OR M.SENSOR

ALARM ON * ACTIVE REC. ON * MOTION SENSOR ON * VIDEO LOSS OFF

DURATION INDIV.* RETRIGGER ON ALARM LIST ON BUZZER ON

ALARM DISPLAY ¤ (*:NEXT)

(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

(ACTIVE REC.SET)

AL.REC.EXT.

REC.MODE MODE1

CAMERA NO.01 T-1 LEVEL:OFF MODE:A

(ALARM DISPLAY SET)

ALARM DISPLAY FULL DOUBLE ALARM LAST

(SPOT MONITOR SET)

SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON

(ALARM DATA) 1/ 1 CAM DATE TIME ITEM

(SEQURITY LOCK SET)

OPERATION CODE 1111 LOCK ON

SECURITY CODE ----

SETUP CODE 1111 LOCK ON

(CAMERA CONTROL SET)

(CONTROL SET)

DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C

IN IN 01:OFF 09:0FF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

CAMERA CONTROL SANYO *

Page 33 of the Fisher MPX-CD163 user manual — BACK
Page 33 · click to enlarge
Page 33

MENU FLOWCHART AND MENU OPERATIONS

Menu operations

(MAIN MENU)

The MAIN MENU screen will be displayed. Note: The MAIN MENU screen will appear on the main monitor and on spot

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

monitor 1.

N Status of indicators when a menu screen is displayed

  • While the MENU indicator is flashing When the MENU button is pressed, the menu screen will be terminated.
  • While the NEXT indicator is flashing When the NEXT button is pressed, a sub-menu screen (the next level) will appear.
  • While the BACK indicator is flashing When the BACK button is pressed, the previous menu screen will be restored.

BACK

NEXT NEXT

Fisher MPX-CD163 — BACK diagram (page 33)
Fig. 33

(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

Page 34 of the Fisher MPX-CD163 user manual — (LANGUAGE)
Page 34 · click to enlarge
Page 34

LANGUAGE SETTING

Fisher MPX-CD163 — LANGUAGE SETTING diagram (page 34)
Fig. 34

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

The multiplexer menu screens can be displayed in several languages (English, French or Spanish). The default language setting is English.

LANGUAGE screen display

The MAIN MENU screen will be displayed.

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Use the cursor button to select “LANGUAGE” and then press the NEXT button.

The LANGUAGE screen will be displayed.

(LANGUAGE)

FRANCAIS

ESPANOL

Use the cursor button to select the language, and then press the MENU button.

The selected language will be set. The camera images will be displayed.

(LANGUAGE)

FRANCAIS

ESPANOL

Page 35 of the Fisher MPX-CD163 user manual — (DAY LIGHT SET)
Page 35 · click to enlarge
Page 35

CLOCK SET SETTINGS

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

(CLOCK SET)

01-01-2001 MON 00:00:00

Set the timer when using the timer function.

TIMER ON ¤ DAY LIGHT ON ¤

(*:NEXT) (TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

(DAY LIGHT SET)

WEEK MON TIME ON 1ST-SUN 04 02:00 OFF LST-SUN 10 02:00

The CLOCK SET menu is used to set the time. It is also used to set a timer when using the timer function, and to make daylight saving settings.

Clock setting · Timer setting · Daylight saving setting

Page 36 of the Fisher MPX-CD163 user manual — (CLOCK SET)
Page 36 · click to enlarge
Page 36

CLOCK SET-1

CLOCK SET SETTINGS

Clock settings (default setting: 01-01-2001 MON 00:00:00)

Be sure to set the clock to the correct time. The correct time must be set in order for the timer setting and summer time setting functions to work correctly.

Example: Setting the clock to October 15, 2002 at 3:20 PM

  • Press the setting buttons to set the year (2002), then press the cursor button.
  • Press the setting buttons to set the hours (15), then press the cursor button.
  • Press the setting buttons to set the minutes (20), then press the cursor button.

(CLOCK SET)

The MAIN MENU screen will be displayed.

10-15-2002 TUE 00:00:00

(MAIN MENU)

(CLOCK SET)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

10-15-2002 TUE 15:00:00

(CLOCK SET)

10-15-2002 TUE 15:20:00

Use the cursor button to select “CLOCK SET”, and then press the NEXT button.

The time setting is finished.

the date entered.

The CLOCK SET screen will be displayed.

(CLOCK SET)

To display date, time and camera number

01-01-2001 MON 00:00:00

BACK

While the camera image is displayed, press the BACK button repeatedly. The following actions will occur:

TIMER ON * DAY LIGHT OFF

10-15-2002 1520 : 00 Camera number

Use the cursor button to select “01”, and then use the setting buttons to set the date.

+ – 3

01 Date, time and camera number

10-15-2002 1520 : 00 Cancel display

(CLOCK SET)

01-01-2001 MON 00:00:00

TIMER ON * DAY LIGHT OFF

10-15-2002 15:20:00 10-15-2002 15:20:00 01

Time is displayed.

+ – 4

  • Press the setting buttons to set the month (10), then press the cursor button.

Setting the time (minutes and seconds) to

00 during monitoring Press the MENU RESET button. The minutes and seconds will then be reset to 00.

(CLOCK SET)

10-01-2001 MON 00:00:00

  • Press the setting buttons to set the day (15), then press the cursor button.

while camera images are being displayed. If you press these buttons while a menu screen is being displayed, the setting values will be reset to their defaults. CLOCK SET-1

(CLOCK SET)

10-15-2001 MON 00:00:00

Date and time

Page 37 of the Fisher MPX-CD163 user manual — CLOCK SET-2
Page 37 · click to enlarge
Page 37

CLOCK SET-2

CLOCK SET SETTINGS

TIMER settings (default setting: 00:00)

For these settings, set Example 2 consecutively with Example 1. Example1: Set TIMER-A and TIMER-B time

zones as follows

The timer function uses two separate timer settings (TIMER-A and TIMER-B), and each timer setting can be made in four time zones (example: midnight, morning, daytime, evening). For example, TIMER-A time zones can be set for automatic screen switching and TIMER-B time zones can be set for gray pattern cover on camera images.

(TIMER-A settings) (TIMER-B settings) T-1 4 a.m. (4:00) T-1 6 a.m. (6:00) T-2 6 a.m. (6:30) T-2 8 a.m. (8:00) T-3 12:30 p.m. (12:30) T-3 2:30 p.m. (14:30) T-4 6 p.m. (18:00) T-4 8 p.m. (20:00)

Press the MENU button, use the cursor button to select CLOCK SET and then press the NEXT button.

Operable functions during the

period set by the timer

Each of the following menu settings is required to operate these timer functions. After you have made the menu settings, be sure to make the timer settings.

Use the cursor button to select TIMER “OFF”.

  • To change camera images into automatic switching screens. Set “ SEQUENCE ” on DISPLAY SET screen
  • To cover camera images with gray pattern. Set “ MASK ” on DISPLAY SET screen

(CLOCK SET)

(DISPLAY SET)

10-15-2001 MON 15:20:00

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

TIMER OFF DAY LIGHT OFF

Press the setting buttons to select “ON”, and then press the NEXT button.

  • To record camera images on a video unit Set “ PROGRAM REC ” on VCR SET screen

The TIMER SET screen will be displayed.

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

(CLOCK SET)

10-15-2001 MON 15:20:00

TIMER ON * DAY LIGHT OFF

PROGRAM REC. ONLY *

Use the cursor button to select TIMER-A “T-1 00:” (hours), and then use the setting buttons to set the hours to “4”.

  • To detect an alarm input in a camera image Set “ MOTION SENSOR ” on ALARM SET screen

+ – 4

(ALARM SET)

ALARM OFF ACTIVE REC. OFF MOTION SENSOR ON * VIDEO LOSS OFF

(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

CLOCK SET-2

Page 38 of the Fisher MPX-CD163 user manual — Note:
Page 38 · click to enlarge
Page 38

CLOCK SET-3

CLOCK SET SETTINGS

Use the cursor button to select TIMER-A “T-1 :00” (minutes), and then use the setting buttons to set the minutes to “00”.

Example2: Set the timer operation as follows

+ – 5

To set TIMER-A time zones to automatic switching

screen and monitor mask. To set TIMER-B timer zones to program recording and

motion sensor.

(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

Use the cursor button to select SEQUENCE “A”, and then use the setting buttons to set “A”. (TIMER-A setting)

+ – 1

Use the cursor button to select TIMER-A “T-2 00:” (hours), and then use the setting buttons to set the hours to “6”.

+ – 6

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 06:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

+ – 2

Use the cursor button to select PROGRAM REC “A”, and then use the setting buttons to set “B”. (TIMER-B setting)

Use the cursor button to select TIMER-A “T-2 00” (minutes), and then use the setting buttons to set the minutes to “30”.

+ – 7

SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A

(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 00:00 T-2 06:30 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

+ – 3

Use the cursor button to select MASK “A”, and then use the setting buttons to set “A”.

Repeat steps 4 and 5 to set the hours and minutes for T-3 and T-4 also.

SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A

Use the same procedure to set the hours and minutes for T-1, T-2, T-3 and T-4.

+ – 4

Use the cursor button to select MOTION SENSOR “A”, and then use the setting buttons to set “B”.

+ – 8

SEQUENCE A PROGRAM REC B MASK A MOTION SENSOR A

(TIMER SET) TIMER-A TIMER-B T-1 04:00 T-1 06:00 T-2 06:30 T-2 08:00 T-3 12:30 T-3 14:30 T-4 18:00 T-4 20:00

BACK 5

Press the BACK button.

Note:

The setting will then be completed and the display will return to the CLOCK SET screen. Press the BACK button once more to return to the MAIN MENU screen. CLOCK SET-3

  • Initial settings T-1 to T-4 are “ 00:00 ” In this case, the timer will operate at all times set by T-1.
  • The time divisions of the timer settings (T-1 to T-4) are continuous settings in one cycle from start time to end time. For instance, in the case of T-1 (4:00) and T-2 (6:30), the domain of timer T-1 is from 4 a.m. until 6:30 a.m.
  • If two more timers are set to the same starting time, the timers will operate together for the same period of time.
  • When setting the timers, a setting cannot be entered if, for instance, T-3 as been set to earlier than T-1. If this happens, re-enter the correct settings.
Page 39 of the Fisher MPX-CD163 user manual — TIMER OFF DAY LIGHT ON *
Page 39 · click to enlarge
Page 39

CLOCK SET-4

CLOCK SET SETTINGS

DAY LIGHT setting (default setting: OFF)

  • Press the setting buttons to set the WEEK (2ND), then press the cursor button. Menu: 1ST, 2ND, 3RD, 4TH or LST

+ – 4

You can set the starting time and ending time for daylight. When daylight is set, the time is automatically advanced by one hour during the summer period.

(first, second, third, fourth or last)

To make changes to the settings Example: Setting the daylight from the

Fisher MPX-CD163 — To make changes to the settings Example: Setting the daylight from the diagram (page 39)
Fig. 35 · To make changes to the settings Example: Setting the…

WEEK MON TIME ON 2ND-SUN 04 02:00 OFF LST-SUN 10 02:00

second Tuesday of May at 3:00 AM, to the fourth Tuesday of September at 3:00 AM.

  • Press the setting buttons to set the WEEK (TUE), then press the cursor button. Menu: SUN, MON, TUE, WED, THU, FRI or SAT

Press the MENU button, use the cursor button to select CLOCK SET and then press the NEXT button.

WEEK MON TIME ON 2ND-TUE 04 02:00 OFF LST-SUN 10 02:00

  • Press the setting buttons to set the MON (05), then press the cursor button. Menu: 1, 2, 3, 4 ..... 11, 12

(for January, February, March December)

Use the cursor button to select DAY LIGHT “OFF”.

Fisher MPX-CD163 — To make changes to the settings Example: Setting the daylight from the diagram (page 39)
Fig. 36 · To make changes to the settings Example: Setting the…

WEEK MON TIME ON 2ND-TUE 05 02:00 OFF LST-SUN 10 02:00

(CLOCK SET)

  • Press the setting buttons to set the TIME (03), then press the cursor button.

10-15-2001 MON 15:30:00

TIMER OFF DAY LIGHT OFF

WEEK MON TIME ON 2ND-TUE 05 03:00 OFF LST-SUN 10 02:00

Press the setting buttons to change the setting to ON, and then press the NEXT button.

Following the same procedure as above, set when the time is changed back from daylight to standard time (the OFF settings).

The DAY LIGHT SET screen will be displayed.

(CLOCK SET)

10-15-2001 MON 15:30:00

WEEK MON TIME ON 2ND-TUE 05 03:00 OFF 4TH-TUE 09 03:00

TIMER OFF DAY LIGHT ON *

The display will return to the normal screen. CLOCK SET-4

Page 40 of the Fisher MPX-CD163 user manual — (CLOCK SET)
Page 40 · click to enlarge
Page 40

DISPLAY SET SETTINGS

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

CAMERA NO.01 CAM DESK 001

CAMERA NO.01 ------- 001

CAMERA NO.01 CAM DESK 001

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN CHANGE¤ SEQUENCE INDIV.¤ MASK ON ¤ MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

(MAIN MON.SEQ SET) T-4 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 06:ON 14:ON 07:ON 15:ON 08:ON 16:ON

(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:OFF 10:ON 03:OFF 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:OFF 14:OFF 07:OFF 15:ON 08:OFF 16:OFF

(CLOCK SET)

01-01-2002 TUE 00:00:00

TIMER ON ¤ DAY LIGHT ON *

(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

(PROGRAM REC.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

(PROGRAM REC SET) TIMER-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 05:ON 14:ON 07:ON 15:ON 08:ON 16:ON

Page 41 of the Fisher MPX-CD163 user manual — CAMERA NO.01 --------01
Page 41 · click to enlarge
Page 41

DISPLAY SET-1

DISPLAY SET SETTINGS

TITLE setting (default setting: DOWN)

A title such as the setup location can be set for each camera, and the position for displaying this title on the monitor screen can also be changed. Example: To assign a title of “HALL-1F” to camera 3 and set the display position to the top of

the monitor

Press camera select button 3.

The MAIN MENU screen will be displayed.

The images from camera 3 will be displayed on the monitor, and the cursor will appear at the default title setting position.

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

CAMERA NO.03 03

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

Use the setting buttons to display “H”, and then press the cursor button.

The DISPLAY SET screen will be displayed.

+ – 6

(DISPLAY SET)

If the cursor button is pressed to the right, the cursor will move to the right. Use this procedure to enter “HALL-1F”.

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

If the title is to be altered, use the cursor buttons to bring the cursor to the item that is to be changed and select a setting button.

Use the cursor button to select TITLE “DOWN”.

  • Alphabetic characters (A – Z)
  • Numerals (0 – 9)
  • Symbols (–, :, ., /, *, _<blank space>)

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S

CAMERA NO.03 H 03 CAMERA NO.03 HALL-1F-03

Use the setting buttons to select “UP”, and then press the NEXT button.

The normal monitoring screen will be displayed and the title will appear at the top of the screen.

BACK button and then re-select “UP” or “DOWN” for the TITLE setting.

(DISPLAY SET)

TITLE UP ¤ MULTI SCREEN NORMAL SEQUENCE 1 S

BACK 7

Press the BACK button.

The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen. DISPLAY SET-1

CAMERA NO.01 01

Page 42 of the Fisher MPX-CD163 user manual — DISPLAY SET-2
Page 42 · click to enlarge
Page 42

DISPLAY SET-2

DISPLAY SET SETTINGS

MULTI SCREEN setting (default setting: NORMAL)

The order in which camera images are displayed in 4-screen, 9-screen and 16-screen displays can be set as desired. Note: The same camera image cannot be displayed more than once on the same screen.

Example 1To display camera 1 image on cameras 06, 11, 16 (in a 4-screen display)

The MPX-CD93 model can display only cameras 01 to 09.

Use the cursor button to move the cursor to “06”, and then press the setting buttons to change the setting to “01”.

5 + –

The MAIN MENU screen will be displayed.

(MAIN MENU)

06 will change to 01.

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Fisher MPX-CD163 — (MAIN MENU) diagram (page 42)
Fig. 37

01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16

01 02 : 05 01 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

The DISPLAY SET screen will be displayed.

6 + –

Repeat step 5 to set the images in 01 to 11 and 16 also.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

You can check the setting by pressing the NEXT button. Press the NEXT button once more to return to the setting screen.

(POSITION SET)

Use the cursor button to select MULTI SCREEN “NORMAL”.

QUAD

Fisher MPX-CD163 — QUAD diagram (page 42)
Fig. 38

01 02 : 05 01 03 04 : 07 08 09 10 : 13 14 01 12 : 15 01

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the setting buttons to select “CHANGE”, and then press the NEXT button.

A 4-screen camera layout screen will be displayed.

9. 12 13 – 16

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN CHANGE* SEQUENCE 1 S MASK OFF

BACK 7

Press the BACK button.

The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.

(POSITION SET)

QUAD

01 02 : 05 06 03 04 : 07 08 09 10 : 13 14 11 12 : 15 16

DISPLAY SET-2

Page 43 of the Fisher MPX-CD163 user manual — BACK 4
Page 43 · click to enlarge
Page 43

DISPLAY SET-3

DISPLAY SET SETTINGS

Example 2To display the image from camera 16 at camera 05 position (in a 16-screen

display)

Use the setting buttons to select “CHANGE”, and then press the NEXT button.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN CHANGE* SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

A 4-screen camera layout screen will be displayed.

+ – 2

Use the setting buttons to call up the 16-screen setting screen.

The display changes to a 9-screen, 16-screen and 4-screen display in that order.

(POSITION SET)

(POSITION SET)

MULTI16

(POSITION SET)

MULTI9

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16

QUAD

01 02 03 04 05 06 07 08 09

01 02 : 05 06 03 04 : 07 08 + 09 10 : 13 14 11 12 : 15 16

The “MULTI16” screen is not available on the MPX-CD93 model.

Use the cursor button to move the cursor to “05”, and then press the setting buttons to change the setting to “16”.

3 + –

(POSITION SET)

(POSITION SET)

MULTI16

MULTI16

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16

01 02 03 04 16 06 07 08 09 10 11 12 13 14 15 05

05 will change to 16 and 16 will change to 05.

You can check the setting by pressing the NEXT button. Press the NEXT button once more to return to the setting screen.

BACK 4

Press the BACK button.

The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen. DISPLAY SET-3

Page 44 of the Fisher MPX-CD163 user manual — (DISPLAY SET)
Page 44 · click to enlarge
Page 44

DISPLAY SET-4

DISPLAY SET SETTINGS

SEQUENCE setting (default setting: 1S)

This lets you set the automatic switching time. The switching time setting for automatic switching display is only effective for single-screen and 4-screen displays. Two types of setting can be made: all cameras can be switched at the same time, or the switching times can be set separately for each camera. Example 1: To set 5-second intervals for automatic switching display of all main and spot

monitor images

BACK 5

Press the BACK button.

The MAIN MENU screen will be displayed.

The setting will then be completed and the display will return to the MAIN MENU screen. When the MENU button is pressed, the display returns to camera image display screen.

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Press the SEQUENCE button while the camera image display screen is displayed.

SEQUENCE 6

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

The screen will switch to 5-second intervals. To stop the screen from switching, press the SEQUENCE button once more. DISPLAY SET-4

The DISPLAY SET screen will be displayed.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the cursor button to select SEQUENCE “1S”.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

+ – 4

Use the setting buttons to select “5S”.

Images can then be switched at intervals of 5 seconds.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 5 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Page 45 of the Fisher MPX-CD163 user manual — INDIV. INTERVAL * (*:NEXT)
Page 45 · click to enlarge
Page 45

DISPLAY SET-5

DISPLAY SET SETTINGS

Example 2: To set the automatic switching period for the main monitor.

  • Set cameras 1 to 8 to 2-second automatic switching displays.
  • Set camera 9 to 16 to 3-second automatic switching displays.

camera are the same as for the main monitor).

Use the cursor button to select SEQUENCE “1S”.

+ – 5

Use the cursor button to select “01:1S”, and then press the setting buttons to change the setting to “2S”.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Automatic switching display at the specified switching interval is enabled when you have entered a switching period for each camera.

Use the setting button (–) to select “INDIV.”, and then press the NEXT button.

With the same procedure:

  • Set 02 to 08 to 2 S.
  • Move the cursor to the right and set 09 to 16 to 3 S.

The SEQUENCE SET screen will be displayed.

(INDIVIDUAL INTERVAL)

(INDIVIDUAL INTERVAL)

IN IN 01: 1 S 09: 1 S 02: 1 S 10: 1 S 03: 1 S 11: 1 S 04: 1 S 12: 1 S 05: 1 S 13: 1 S 06: 1 S 14: 1 S 07: 1 S 15: 1 S 08: 1 S 16: 1 S

IN IN 01: 2 S 09: 3 S 02: 2 S 10: 3 S 03: 2 S 11: 3 S 04: 2 S 12: 3 S 05: 2 S 13: 3 S 06: 2 S 14: 3 S 07: 2 S 15: 3 S 08: 2 S 16: 3 S

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

MENU BACK 6

Press the BACK button.

Use the cursor button to select the MAIN MONITOR “1S” setting, and then press the setting buttons (–) to change the setting to “INDIV.”.

The setting will then be completed. Press the BACK button once more to return to the MAIN MENU screen.

INDIV. INTERVAL appears at the bottom of the screen.

The display will return to the camera image display screen. If the SEQUENCE button is then pressed, the screen images will start switching automatically according to the settings that have been made. DISPLAY SET-5

(SEQUENCE SET)

MAIN MONITOR INDIV.¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S

INDIV. INTERVAL * (*:NEXT)

Use the cursor button to select “INDIV. INTERVAL” and then press the NEXT button.

The INDIVIDUAL INTERVAL screen will be displayed.

(SEQUENCE SET)

MAIN MONITOR INDIV.¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S

INDIV. INTERVAL * (*:NEXT)

Page 46 of the Fisher MPX-CD163 user manual — (DISPLAY SET)
Page 46 · click to enlarge
Page 46

DISPLAY SET-6

DISPLAY SET SETTINGS

Example 3To set a 5-second interval for the automatic switching display of main monitor

images and to use the timer function to set a period when automatic switching display is not required. 1 Set “TIMER” on CLOCK SET to ON, set each timer

+ – 6

Use the cursor button to select the MAIN MONITOR “1S” setting, and then press the setting buttons to change the setting to “5S”.

of TIMER-A and TIMER-B on TIMER SET to SEQUENCE and terminate CLOCK SET.

The automatic switching period for the main monitor will be set to 5 seconds.

The MAIN MENU screen will be displayed.

(SEQUENCE SET)

MAIN MONITOR 5 S ¤ SPOT MONITOR-1 1 S ¤ SPOT MONITOR-2 1 S ¤ SPOT MONITOR-3 1 S ¤ SPOT MONITOR-4 1 S ¤ QUAD 1 S

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Press the NEXT button. The MAIN MON. SEQ. SET “T-1” screen will be displayed.

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

This screen is for selecting whether images from cameras 1 to 16 will be displayed at the time specified by the timer (T-1). Note: T-1 will not be displayed if TIMER on

The DISPLAY SET screen will be displayed.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

CLOCK SET is OFF.

(MAIN MON.SEQ.SET) T-1 IN IN 01:ON 09:ON 02:ON 10:ON 03:ON 11:ON 04:ON 12:ON 05:ON 13:ON 06:ON 14:ON 07:ON 15:ON 08:ON 16:ON

Use the cursor button to select SEQUENCE “1S”.

(DISPLAY SET)

Use the cursor button to select “example: 01:ON”, and then press the setting buttons to change the setting to “OFF”.

+ – 8

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the same procedure to set OFF cameras 2 (02) to 08.

Use the setting button (–) to select “INDIV.” and then press the NEXT button.

(MAIN MON.SEQ.SET) T-1 IN IN 01:OFF 09:ON 02:OFF 10:ON 03:OFF 11:ON 04:OFF 12:ON 05:OFF 13:ON 06:OFF 14:ON 07:OFF 15:ON 08:OFF 16:ON

The SEQUENCE SET screen will be displayed.

(DISPLAY SET)

DISPLAY SET-6

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE INDIV.* MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Page 47 of the Fisher MPX-CD163 user manual — Note:
Page 47 · click to enlarge
Page 47

DISPLAY SET SETTINGS

Use the cursor button to select “T-1”, and then press the setting buttons to change the setting to “T-2”.

+ – 9

The display will return to the camera image display screen. If the SEQUENCE button is then pressed, the screen images will start switching automatically according to the settings that have been made.

SEQUENCE

Press the setting buttons repeatedly to switch T-1, 2, 3, 4.

(MAIN MON.SEQ.SET) T-2

Example of automatic switching display

(MAIN MON.SEQ.SET) T-3

(MAIN MON.SEQ.SET) T-4

Use the cursor button to select “example: 09:ON”, and then press the setting buttons to change the setting to “OFF”. Use the same procedure to set OFF cameras 10 (10) to 16.

+ – 10

(MAIN MON.SEQ.SET) T-2 IN IN 01:ON 09:OFF 02:ON 10:OFF 03:ON 11:OFF 04:ON 12:OFF 05:ON 13:OFF 06:ON 14:OFF 07:ON 15:OFF 08:ON 16:OFF

If you wish, T-3 and T-4 may be

set with the same operations as in steps 9 to 10.

Press the BACK button.

BACK 11

The setting will then be completed and the display will return to the SEQUENCE SET screen. Press the BACK button once more to return to the DISPLAY SET screen.

Note:

  • When making settings for a spot monitor, select SPOT MONITOR-1, -2, -3 or -4 and then follow the same procedure.
  • For QUAD screen displays, the timer function cannot be used to carry out automatic switching of the display. DISPLAY SET-7
Page 48 of the Fisher MPX-CD163 user manual — (DISPLAY SET)
Page 48 · click to enlarge
Page 48

DISPLAY SET SETTINGS

MASK settings (default: OFF)

If you do not need images from some cameras to appear on the monitor screen, you can cover these camera images with gray patterns. Example 1: To prevent monitoring of images from cameras 5 (05) to 10

For the MPX-CD93 model, the settings are from cameras 01 to 09. 1 Set TIMER on CLOCK SET to OFF.

+ – 6

Use the cursor button to select “05:OFF”, and then press the setting buttons to change the setting to “ON”.

If TIMER has been set to ON, a display such as T-1 will appear when the timer is set.

Use the same procedure to set from 6 to 10 to “ON”.

The MAIN MENU screen will be displayed.

(MASK SET) T-1 IN IN 01:OFF 09:ON 02:OFF 10:ON 03:OFF 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:ON 14:OFF 07:ON 15:OFF 08:ON 16:OFF

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Press the BACK button.

BACK 7

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.

The DISPLAY SET screen will be displayed.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

The display will return to the camera image display screen. Display example:

Use the cursor button to select MASK “OFF”.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET-8

Use the setting buttons to select “ON”, and then press the NEXT button.

The MASK SET screen will be displayed.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Page 49 of the Fisher MPX-CD163 user manual — DISPLAY SET-9
Page 49 · click to enlarge
Page 49
Fisher MPX-CD163 — Playing back automatically switching images diagram (page 49)
Fig. 39 · Playing back automatically switching images
Example 2To prevent monitoring of unnecessary camera images at a time specified by the

timer 1 Set TIMER on CLOCK SET to ON, set each timer

+ – 6

Use the cursor button to select “example: 02:OFF”, and then press the setting buttons to change the setting to “ON”.

of TIMER-A and TIMER-B on TIMER SET to MASK and terminate CLOCK SET.

Use the same procedure to set 04, 06, 08 and 10 to “ON”.

The MAIN MENU screen will be displayed.

(MASK SET) T-1 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 06:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Use the cursor button to select “T-1”, and then press the setting buttons to change the setting to “T-2”.

+ – 7

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

The DISPLAY SET screen will be displayed.

The MASK SET “T-2” screen will be displayed. Press the setting buttons repeatedly to switch T-1, 2, 3, 4.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

(MASK SET) T-2

(MASK SET) T-3

(MASK SET) T-4

Use the cursor button to select MASK “OFF”.

+ – 8

Use the cursor button to select “example: 01:OFF”, and then press the setting buttons to change the setting to “ON”.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the same procedure to set 03, 05, 07 and 09 to “ON”.

Use the setting buttons to select “ON”, and then press the NEXT button.

If you wish, T-3 and T-4 may be set with the same operations as in steps 6 to 7.

The MASK SET screen will be displayed. This screen is for selecting whether images from cameras 1 to 16 will be masked at the time specified by the timer (T-1).

(MASK SET) T-2 IN IN 01:ON 09:ON 02:OFF 10:OFF 03:ON 11:OFF 04:OFF 12:OFF 05:ON 13:OFF 06:OFF 14:OFF 07:ON 15:OFF 08:OFF 16:OFF

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK ON * MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET-9

Page 50 of the Fisher MPX-CD163 user manual — DISPLAY SET-10
Page 50 · click to enlarge
Page 50

DISPLAY SET-10

DISPLAY SET SETTINGS

Press the BACK button.

MAIN → SPOT 1 setting (default setting: OFF)

BACK 9

The setting will then be completed and the display will return to the DISPLAY SET screen. Press the BACK button once more to return to the MAIN MENU screen.

The same camera images that are being displayed on the main monitor can also be displayed on spot monitor 1. This feature can be used to allow another person to monitor the 16-screen display (spot monitor 1) in another room.

The camera image display menu is restored. At the time specified by the timer settings, the specified camera images will be covered with a gray pattern.

The MAIN MENU screen will be displayed.

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Examples of masking at times specified by timer settings

Fisher MPX-CD163 — Examples of masking at times specified by timer settings diagram (page 50)
Fig. 40 · Examples of masking at times specified by timer sett…

Use the cursor button to select “DISPLAY SET” and then press the NEXT button.

The DISPLAY SET screen will be displayed.

T – 1 (6:00 – 12:00) T – 2 (12:00 – 16:00)

Fisher MPX-CD163 — Examples of masking at times specified by timer settings diagram (page 50)
Fig. 41 · Examples of masking at times specified by timer sett…

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Use the cursor button to select MAIN→SPOT1 “OFF”, and then press the setting buttons to change the setting to “ON”.

+ – 3

T – 3 (16:00 – 24:00) T – 4 (24:00 – 6:00)

When set to “ON”, identical images will be displayed on both the main monitor and spot monitor 1.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 ON DIGITAL CONNECTION OFF COLOR LEVEL AUTO

DISPLAY SET-10

Page 51 of the Fisher MPX-CD163 user manual — DISPLAY SET-11
Page 51 · click to enlarge
Page 51

DISPLAY SET-11

DISPLAY SET SETTINGS

  • DIGITAL CONNECTION settings (default setting: OFF (this unit only))
  • With four of these units connected, each unit can be controlled separately. Images can be viewed on one monitor. If several units are connected, control settings must be made to identify one unit as the main unit for main control and the others as sub-units.
  • Digital video recorders can be connected to this unit. If a digital video recorder has been connected, it can be controlled from this unit.

Note:

  • Images from sub-units will not be displayed.
  • When several units are connected, the unit closest to the main unit should be specified as SUB1.

Press the MENU button to terminate the operation of this unit.

A: Operation of four units with digital

5 Use the same procedure to specify other

connections

sub-units (SUB2, 3).

For making connections, please refer to “Digital connections”. (See page 9.)

Method of control

When the main unit and sub-units have been specified, the camera images of the main unit will appear on the monitor and only the main unit can be controlled. The indicator lamps of all other sub-units will be turned off. When another sub-unit is to be controlled, press the LIVE button of the other sub-unit. The sub-unit indicator will illuminate, the main unit lamp will turn off, and the camera image of the sub-unit will appear on the monitor.

Main unit settings

+ – 1

Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select MAIN.

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION MAIN COLOR LEVEL AUTO

B: Digital connection of a digital video

recorder (sold separately) to this unit

Display examples:

  • OFF: When one of these units is connected
  • MAIN: When several units are connected, one is used as the main control unit.
  • SUB1 (2 , 3): When several units are connected, the others are used as sub-units.
  • DVR: When one of these units is used with a digital video recorder connected.

For making connections, please refer to “Digital connections”. (See page 10.)

+ – 1

Digital video recorder settings

Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select DVR.

(DISPLAY SET)

Press the MENU button to terminate the operation of this unit.

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION DVR COLOR LEVEL AUTO

Press the MENU button to terminate the operation of this unit.

Sub-unit settings

+ – 3

Use the cursor button to select DIGITAL CONNECTION “OFF” and press the setting buttons to select SUB1.

DISPLAY SET-11

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION SUB1 COLOR LEVEL AUTO

Page 52 of the Fisher MPX-CD163 user manual — Display examples:
Page 52 · click to enlarge
Page 52

DISPLAY SET-12

DISPLAY SET SETTINGS

Method of control

COLOR LEVEL settings

To play back a digital video recorder (sold separately) from this unit 1. Make the following setting on the digital video recorder’s VIDEO INPUT SET menu.

To adjust the monitor screen color level.

+ – 1

Use the cursor buttons to select COLOR LEVEL “AUTO” and then press the setting buttons to adjust the color level.

  • Set MULTIPLEXER to SANYO.
  • Set VIDEO INPUT to DIGITAL.
(VIDEO INPUT SET) MULTIPLEXERSANYO VIDEO INPUT : DIGITAL

(DISPLAY SET)

TITLE DOWN ¤ MULTI SCREEN NORMAL SEQUENCE 1 S MASK OFF MAIN†SPOT1 OFF DIGITAL CONNECTION OFF COLOR LEVEL AUTO

Display examples:

recorder for details on the VIDEO INPUT setting. 2. Press the VCR button on this unit and press the cursor (c) button.

  • AUTO: Adjusts the color level automatically.
  • 1 to 10: Adjusts the color level manually. The larger the number, the more intense is the monitor color.

The digital video recorder playback image will appear on the monitor.

signal is extremely attenuated by the effect of a cable, for example, color can be forcibly applied. DISPLAY SET-12

3. Press the cursor, NEXT and setting buttons to enable operations such as the following.

While it is operating, the digital video recorder indicator will illuminate or flash. (Cursor buttons) 1 j: Still image 2 c: Playback 3 d: Reverse play 4 l: Stop 5 (NEXT button) If you press this button when several digital video recorders are connected, you will be switched in sequence from the digital video recorder nearest to this unit. (Setting buttons) 6 +: Increase playback speed 7 –: Decrease playback speed

(RS-485).

Fisher MPX-CD163 — Display examples: diagram (page 52)
Fig. 42 · Display examples:
Page 53 of the Fisher MPX-CD163 user manual — VCR SET SETTINGS
Page 53 · click to enlarge
Page 53

VCR SET SETTINGS

This lets you select a recording device for recording camera images. The recording speed for these recorded images and the recording speed when there is an alarm can be selected, and the recording method to be used for recording camera images can also be selected.

Page 54 of the Fisher MPX-CD163 user manual — VCR SET-1
Page 54 · click to enlarge
Page 54

VCR SET-1

VCR SET SETTINGS

VCR SET settings are for specifying how a unit to record images from a camera will carry out the recording.

VCR SET settings

Switch (SW) wave pattern signal timing setting

  • If the recording unit has a SW signal output connector
  • If a SW signal is output A signal from the video output connector of this unit is switched automatically to the recording speed and sent to the recording unit, by means of a SW signal (recording speed pulse signal) that has been specified by the recording unit for which the speed for recording images output from this unit has been selected. In cases such as this there is no need to specify REC. SPEED and ALARM REC. SPEED settings for this unit.
  • If a SW signal is not output Even if there is a connection between the selected recording unit (SW signal output connector) and this unit, it sometimes happens that the SW signal is not output only in the case of 3-hour and 6-hour video recording speeds. In cases such as this, the REC. SPEED and ALARM REC. SPEED settings for this unit must be specified. (VCR only)

The MAIN MENU screen will be displayed.

(MAIN MENU)

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

Use the cursor button to select “VCR SET” and then press the NEXT button.

The VCR SET screen will be displayed.

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

PROGRAM REC. OFF

If the recording unit does not have a SW signal output connector

+ – 3

Use the cursor button to select RECORDER (example: TLS), and press the setting buttons.

Match REC. SPEED and ALARM REC. SPEED of this unit to the recording speed of the recording unit that is connected. Settings are not required for a digital video recorder.

Use the setting buttons to switch the recording unit.

Fisher MPX-CD163 — PROGRAM REC. OFF diagram (page 54)
Fig. 43

When a time lapse VCR is selected

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H

VCR SET-1

When a real time VCR is selected

RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H

When a digital video recorder is selected

RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S

Page 55 of the Fisher MPX-CD163 user manual — PROGRAM REC. OFF
Page 55 · click to enlarge
Page 55

VCR SET-2

VCR SET SETTINGS

Use the cursor button to select REC. SPEED (example: 2H), and press the setting buttons to set the recording speed.

Use the cursor button to select ALARM REC. SPEED (example: 2H), and press the setting buttons to set the alarm recording speed.

+ – 4

+ – 5

  • For a time lapse VCR (TLS): (default setting: 2H) The recording speed is the recording time when a T-120 tape is being used.
  • For a time lapse VCR (TLS): (default setting: 2H) The recording speed is the recording time when a T-160 tape is being used.

(VCR SET)

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

2, 12, 24, 48, 72, 96, 120, 168, 240, 360, 480, 720, 960

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

2, 12, 24, 48H, NC, F2

PROGRAM REC. OFF

PROGRAM REC. OFF

NCRecording is carried out at the set alarm recording
  • For a real time VCR (REAL): (default setting: 6H) The recording speed is the recording time when a T-160 tape is being used.

speed when an alarm is received. F2: Use this setting when using the SW signal output

connector of a VCR and no switch signal is output for 2 H.

(VCR SET)

  • For a real time VCR (REAL): (default setting: 6H) The recording speed is the recording time when a T-160 tape is being used.

RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H SW.IN EDGE ñ REC.PICTURE 01

6, 18, 30, 48, 72, 96, 120, 168, 240, 360, 480, 720, 960

PROGRAM REC. OFF

(VCR SET)

RECORDER REAL REC.SPEED 6 H ALARM REC.SPEED 6 H SW.IN EDGE ñ REC.PICTURE 01

6, 18, 30, 48H, NC, F6

recording speed for the video device as follows.

PROGRAM REC. OFF

Multiplexer recording speed Real time VCR recording

6 (6 hours) 8H (8 hours)

NCRecording is carried out at the set alarm recording

18 (18 hours) 24H (24 hours)

speed when an alarm is received. F6: Use this setting when using the SW signal output

30 (30 hours) 40H (40 hours)

connector of a VCR and no switch signal is output for 6 H.

  • For a digital video recorder (DVR): (default setting: 0.02 S)
  • For a digital video recorder (DVR): (default setting: 0.02 S)

(VCR SET)

(VCR SET)

RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S SW.IN EDGE ñ REC.PICTURE 01

0.02, 0.03, 0.05, 0.07, 0.10, 0.13, 0.17, 0.20, 0.23, 0,27, 0.30, 0,33, 0.37, 0.43, 0.50, 0.60, 0.70, 0.80, 0.90, 1, 2, 3, 4, 5, 10, 20, 30 S

RECORDER DVR REC.SPEED 0.02 S ALARM REC.SPEED 0.02 S SW.IN EDGE ñ REC.PICTURE 01

0.02, 0.03, 0.05, 0.07, 0.10, 0.13, 0.17, 0.20, 0.23, 0,27, 0.30, 0,33, 0.37, 0.43, 0.50, 0.60, 0.70, 0.80, 0.90, 1, 2, 3, 4, 5, 10, 20, 30 S, NC

PROGRAM REC. OFF

PROGRAM REC. OFF

NCRecording is carried out at the set recording speed

even if an alarm is received.

speed is 2H or 6H, even though the recording device has a SW signal output connector. If this happens, set the alarm recording speed as follows.

Recording speed Alarm recording

speed Time lapse VCR 2H F2 Real time VCR 6H F6 VCR SET-2

speed

Page 56 of the Fisher MPX-CD163 user manual — VCR SET-3
Page 56 · click to enlarge
Page 56

VCR SET-3

VCR SET SETTINGS

Use the cursor button to select SW. IN EDGE (example: ↓), and then press the setting buttons.

+ – 6

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

PROGRAM REC. OFF

Display examples:

  • ↑ : Switch timing on rising edge of SW signal
  • ↓ : Switch timing on falling edge of SW signal
  • ↑↓ : Switch timing on both rising and falling edges of SW signal

Use the cursor button to select REC. PICTURE (example: 01), and then press the setting buttons.

+ – 7

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

PROGRAM REC. OFF

  • This sets how many copies of the image from the various cameras are recorded when they are output from the VCR OUT connector. When this setting is made, it eliminates the cross talk that can occur when the camera images are recorded.
  • The same image can be recorded continuously up to a maximum of 99 times.
  • Even if this setting is set to 1, the PROGRAM REC. and ACTIVE REC. settings may prevent recording of images one at a time.

VCR SET-3

Page 57 of the Fisher MPX-CD163 user manual — VCR SET-4
Page 57 · click to enlarge
Page 57

VCR SET SETTINGS

PROGRAM REC. setting

Example 1: To record images from cameras

Display examples:

1, 2 and 3 in MODE 1

  • OFF: PROGRAM REC. cannot be carried out. Images from all connected cameras are recorded in the same way.
  • ONLY: Only images from the cameras which have output set to ON are recorded.

The MAIN MENU screen will be displayed.

  • Recording pattern when camera 1, 2 and 3 are ON

(MAIN MENU)

Only images from cameras selected (ON) are recorded.

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

  • MODE1: Recording alternates between images from the cameras which have output set to ON and images from all cameras that are connected. If image output from multiple cameras has been set to ON, images from the cameras that are set to ON and images from all cameras are alternately recorded one image at a time.

Use the cursor button to select “VCR SET” and then press the NEXT button.

The VCR SET screen will be displayed.

  • Recording pattern when camera 1, 2 and 3 are ON

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

Images from cameras selected (ON) and images from all cameras are recorded alternately.

Fisher MPX-CD163 — (VCR SET) diagram (page 57)
Fig. 44

PROGRAM REC. OFF

Use the cursor button to select PROGRAM REC. “OFF”, press the setting buttons to change the setting to “MODE1”, and then press the NEXT button.

  • MODE2: Recording alternates between images from the cameras which have output set to ON and images from all cameras that are connected. If image output from multiple cameras has been set to ON, all images from the cameras that are set to ON are recorded first, and then images from all cameras are recorded one image at a time.

The PROGRAM REC. SET screen will be displayed. Refer to the display example to select program recording.

Fisher MPX-CD163 — PROGRAM REC. OFF diagram (page 57)
Fig. 45
  • Recording pattern when camera 1, 2 and 3 are ON

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

VCR SET-4

Page 58 of the Fisher MPX-CD163 user manual — VCR SET-5
Page 58 · click to enlarge
Page 58

VCR SET-5

VCR SET SETTINGS

Use the cursor button to select “example: 04:ON”, and then press the setting buttons to change the setting to “OFF”.

+ – 4

Now camera 4 cannot be recorded. Use the same procedure to set 05 – 16 to “OFF”.

(PROGRAM REC.SET)

IN IN 01:ON 09:OFF 02:ON 10:OFF 03:ON 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 05:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

MENU BACK 5

Press the BACK button, and then press the MENU button.

The display returns to the MAIN MENU screen.

6 Record

Carry out the necessary steps at the recording device to start recording. The images from cameras 1, 2 and 3 that are set to ON will be recorded in the MODE1 format.

VCR SET-5

Page 59 of the Fisher MPX-CD163 user manual — + – 4
Page 59 · click to enlarge
Page 59

VCR SET-6

VCR SET SETTINGS

Example 2: To record in MODE2 using the

Use the cursor button to select “T-1”, and then press the setting buttons to change it to “T-2”.

+ – 5

timer function

For the MPX-CD93 model, please specify cameras 1 to 9.

The (PROGRAM REC. SET) T-2 screen will be displayed.

The MAIN MENU screen will be displayed.

(PROGRAM REC.SET) T-2 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 05:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

+ – 6

Use the cursor button to select “02:ON”, and then press the setting buttons to change the setting to “OFF”.

Use the cursor button to select TIMER “OFF” in the CLOCK SET menu, press the setting buttons to change the setting to “ON”, and then press the NEXT button.

Use the same procedure to set 04, 06, 08, 10, 11, 12, 13, 14, 15 and 16 to “OFF” also. Repeat steps 5 and 6 to change the settings for T-3 and T-4.

Once the timer settings have been made, the display returns to the MAIN MENU screen with “VCR SET” selected.

BACK 7

Press the BACK button.

Use the cursor button to select “MODE2” and then press the NEXT button.

Once the setting is complete, the display will return to the VCR SET screen. Press the BACK button once more to return to the MAIN MENU screen.

(VCR SET)

RECORDER TLS REC.SPEED 2 H ALARM REC.SPEED 2 H SW.IN EDGE ñ REC.PICTURE 01

Press the MENU button and then start recording.

PROGRAM REC. MODE2

Carry out the necessary steps at the recording device to start recording. Camera images will be recorded in MODE2 using the timer function.

  • The (PROGRAM REC. SET) T-1 screen will be displayed.

VCR SET-6

Use the cursor button to select “example: 01:ON”, and then press the setting buttons to change the setting to “OFF”.

+ – 4

Use the same procedure to set 03, 05, 07, 09, 11, 12, 13, 14, 15 and 16 to “OFF” also.

(PROGRAM REC.SET) T-1 IN IN 01:OFF 09:OFF 02:ON 10:ON 03:OFF 11:OFF 04:ON 12:OFF 05:OFF 13:OFF 05:ON 14:OFF 07:OFF 15:OFF 08:ON 16:OFF

Page 60 of the Fisher MPX-CD163 user manual — CAMERA NO.01 T-1 LEVEL:OFF MODE:A
Page 60 · click to enlarge
Page 60

ALARM SET SETTINGS

(MAIN MENU)

Alarm setting (See page 61.)

Lets you make various alarm settings.

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

(ALARM OPERATION SET)

(ALARM DISPLAY SET)

ALARM EXT.OR M.SENSOR

ALARM DISPLAY FULL DOUBLE ALARM LAST

DURATION INDIV.* RETRIGGER OFF ALARM LIST ON BUZZER ON

(SPOT MONITOR SET)

SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON

ALARM DISPLAY ¤ (*:NEXT)

Active recording setting (See page 64.)

Select the type of alarms to record.

(ALARM SET)

(ACTIVE REC.SET)

AL.REC. EXT. REC.MODE MODE1

ALARM ON * ACTIVE REC. ON * MOTION SENSOR ON * VIDEO LOSS FREEZE

Select which recording method to use for recording.

Multiple alarm images are recorded alternately.

Use the timer function to carry out recording. (See page 45.)

MODE2

Multiple alarm images are recorded alternately.

If the motion sensor has been set and a suspicious person is detected, alarm recording is carried out for the length of time set by the timer.

Alarm Alarm canceled ONLY

Recording continues until the alarm is canceled.

Timer setting (See page 36.)

(CLOCK SET)

Sets monitoring sensors. Motion sensor alarm setting (See page 67.)

01-01-2001 MON 00:00:00

TIMER ON ¤ DAY LIGHT OFF

AAAAAA AAAAAA AAAAAA

(TIMER SET) TIMER-A TIMER-B T-1 00:00 T-1 00:00 T-2 00:00 T-2 00:00 T-3 00:00 T-3 00:00 T-4 00:00 T-4 00:00

CAMERA NO.01 T-1 LEVEL:OFF MODE:A

SEQUENCE A PROGRAM REC A MASK A MOTION SENSOR A

Camera signal loss detection (See page 68.)

When camera images are lost, the screen appears as a still image or a test pattern.

AAAAAA AAAAAA AAAAAA

VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS VIDEO LOSS

CAMERA NO.01 T-1 LEVEL:OFF MODE:A

Test pattern Still image

Show 5 more labels / short text on this page
Alarm MODE1 · Alarm · Alarm Alarm · -------- ------ · -------- ------
Page 61 of the Fisher MPX-CD163 user manual — Type of Alarm Multiplexer operation Monitor screen display Alarm List
Page 61 · click to enlarge
Page 61

ALARM SET SETTINGS

There are three types of alarm detection: external alarm, motion sensor alarm and no signal alarm. Alarm settings include specifying the period during which the buzzer will continue to sound and the method of recording images during each alarm.

Type of Alarm Multiplexer operation Monitor screen display Alarm List

External alarm detection By setting up a door switch, etc. connected to the alarm input connecter at the rear of this unit, an intruder opening or closing the door can be detected. When it is detected, the buzzer will sound.

When an alarm occurs, the indicator on the camera select button for the camera that produced the alarm (example: 4) will start flashing.

The image from the camera that produced the alarm (example: 4) will be displayed and “EA” (external alarm) will appear on the screen.

When an alarm occurs, the alarm history is recorded in the alarm list. The histories of up to 100 events can be displayed.

Motion sensor alarm detection By setting the sensitivity of a motion sensor built into this unit an intruder can be detected on the monitor screen and the buzzer will sound.

The image from the camera that produced the alarm (example: 4) will be displayed and “SA” (sensor alarm) will appear on the screen.

(ALARM LIST) 1/13 CAM DATE TIME ITEM 1 4 08-22 08:48 E 2 2 08-21 08:51 S 3 4 05-04 16:22 E 4 3 05-04 07:45 V 5 1 04-30 14:37 E 6 1 04-21 18:26 V 7 2 04-12 05:31 E 8 4 04-12 12:51 E

CAMERA NO.04 T-1 LEVEL:OFF MODE:A

The codes in the ITEM column indicate the type of alarm data. E: External alarm trigger S: Motion sensor trigger V: Video loss

Signal loss detection alarm In the case of a camera signal being suddenly interrupted due to an accident, etc., a setting can be made to record the image immediately prior to the interruption (a still image or a test pattern). When it is detected the buzzer will sound.

When an alarm occurs, the screen changes to a still image or a test pattern, and the video loss detection alarm display (VIDEO LOSS) will appear on the screen.

Show 6 more labels / short text on this page
For external alarms · Camera number · For sensor alarms · Camera number · Still image · Test pattern
Page 62 of the Fisher MPX-CD163 user manual — ALARM DISPLAY ¤
Page 62 · click to enlarge
Page 62

ALARM SET-1

ALARM SET SETTINGS

ALARM SET settings Example: To use both an external alarm and

  • EXT.: An alarm is only generated when an external alarm is detected.
  • M.SENSOR: An alarm is only generated when a motion sensor alarm is detected.

the motion sensor to detect alarms

The MAIN MENU screen will be displayed.

Use the cursor button to select DURATION “10S”, and then press the setting buttons to select “5”.

+ – 5

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

An alarm display time of 5 seconds has been set.

(ALARM OPERATION SET)

ALARM EXT.AND M.SENSOR

Use the cursor button to select “ALARM SET” and then press the NEXT button.

DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON

ALARM DISPLAY ¤

The ALARM SET screen will be displayed.

1, 2, 3, 4, 5, 10, 20 ... (in 10-second intervals), 180S, CC, NC, INDIV.

(ALARM SET)

ALARM ON * ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF

Display examples:

  • CC: An alarm is generated only while the alarm is actually being detected. (Minimum duration 1 second)
  • NC: An alarm is generated until the alarm detection is reset.
  • INDIV.: This lets you set the alarm duration separately for each camera.

Use the cursor button to select ALARM “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.

+ – 6

Use the cursor button to select RETRIGGER “OFF”, and then press the setting buttons to select “ON”.

The ALARM OPERATION SET screen will be displayed.

(ALARM OPERATION SET)

ALARM EXT.AND M.SENSOR

DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON

ALARM DISPLAY ¤

Use the cursor buttons to select ALARM “EXT. OR M.SENSOR”, and then press the setting buttons to select the “EXT. AND M. SENSOR”.

+ – 4

Display examples:

  • OFF: Simultaneous alarms are not detected.
  • ON: Simultaneous alarms are detected. ALARM SET-1

(ALARM OPERATION SET)

ALARM EXT.AND M.SENSOR

DURATION 10 S RETRIGGER OFF ALARM LIST ON BUZZER ON

ALARM DISPLAY ¤

Display examples: The following four alarm detection methods are available.

  • EXT. OR M.SENSOR: An alarm is generated when either an external alarm or a motion sensor alarm is detected.
  • EXT. AND M.SENSOR: An alarm is generated when both an external alarm and a motion sensor alarm is detected.
Page 63 of the Fisher MPX-CD163 user manual — ALARM SET-2
Page 63 · click to enlarge
Page 63

ALARM SET-2

ALARM SET SETTINGS

Use the cursor button to select ALARM LIST “ON”.

Example: To set the alarm duration

+ – 7

  • 3 seconds for cameras 01 and 05 Use the cursor button to select DURATION “10S”.

The number of the camera where the alarm was detected, the date, time and the type of alarm are recorded in the alarm list.

(ALARM OPERATION SET)

(ALARM OPERATION SET)

ALARM EXT.AND M.SENSOR

ALARM EXT.AND M.SENSOR

DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON

DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON

ALARM DISPLAY ¤

ALARM DISPLAY ¤

Display examples:

Use the setting buttons to select “INDIV.”, and then press the NEXT button.

  • OFF: Alarm list is not recorded.
  • ON: Alarm list is recorded.

The ALARM DURATION SET screen will be displayed.

+ – 8

Use the cursor button to select BUZZER “ON”.

(ALARM OPERATION SET)

The buzzer will sound when an alarm is detected.

ALARM EXT.AND M.SENSOR

DURATION INDIV.* RETRIGGER ON ALARM LIST ON BUZZER ON

(ALARM OPERATION SET)

ALARM EXT.AND M.SENSOR

ALARM DISPLAY ¤ (*:NEXT)

DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON

+ – 3

Use the cursor button to select “01:10S”, and then press the setting buttons to change the setting to “3S”.

ALARM DISPLAY ¤

Display examples:

  • OFF: The buzzer does not sound when an alarm is detected.
  • ON: The buzzer sounds when an alarm is detected.

Use the same procedure to set the alarm duration for cameras 02, 03, 04 and 05.

(ALARM DURATION SET)

IN IN 01: 3 S 09:10 S 02: 3 S 10:10 S 03: 3 S 11:10 S 04: 3 S 12:10 S 05: 3 S 13:10 S

multiplexer. If setting the buzzer to sound, place the multiplexer so that the buzzer sound can be heard from the multiplexer. ALARM SET-2

The display will return to the camera image display screen. When an alarm is detected at the cameras that have been set, an alarm is displayed for the setting duration.

Example of alarm duration display

Cameras 01 to 05

ALARM SET-2

Alarm displayed · for 3 seconds

Page 64 of the Fisher MPX-CD163 user manual — ALARM SET-3
Page 64 · click to enlarge
Page 64

ALARM SET-3

ALARM SET SETTINGS

ALARM DISPLAY setting (default settingFULL) Example: To set the alarm screen to a

Use the cursor button to select DOUBLE ALARM “LAST”, and then press the setting buttons to select “example: FIRST”.

+ – 6

single-screen when an alarm is detected and another alarm has occurred. 1 Press the MENU button.

(ALARM DISPLAY SET)

ALARM DISPLAY FULL DOUBLE ALARM FIRST

(SPOT MONITOR SET)

SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON

The MAIN MENU screen will be displayed. 2 Use the cursor button to select “ALARM SET”

Display examples:

  • LAST: When more than one alarm is detected at around the same time, the alarm which was received last is given priority.
  • FIRST: When more than one alarm is detected at around the same time, the alarm which was received first is given priority.
  • SWITCH: When more than one alarm is detected at around the same time, the display switches between the images from all alarms at 1-second intervals.

and then press the NEXT button.

The ALARM SET screen will be displayed.

Fisher MPX-CD163 — Display examples: diagram (page 64)
Fig. 46 · Display examples:

ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF

Use the cursor button to select ALARM “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.

SPOT MONITOR SET setting (default setting: ON) Example: When an alarm is detected, a

single-screen alarm image is displayed on four spot monitors.

Use the cursor button to select “ALARM DISPLAY” and then press the NEXT button.

+ – 1

Use the cursor button to select SPOT MONITOR-1 “ON”.

(ALARM DISPLAY SET)

ALARM DISPLAY FULL DOUBLE ALARM LAST

(SPOT MONITOR SET)

DURATION 10 S RETRIGGER ON ALARM LIST ON BUZZER ON

SPOT MONITOR-1 ON SPOT MONITOR-2 ON SPOT MONITOR-3 ON SPOT MONITOR-4 ON

Display examples:

  • ON: Alarm images are displayed on the spot monitor.
  • OFF: Alarm images are not displayed on the spot monitor.

Use the cursor button to select ALARM DISPLAY “FULL”.

Use the same procedure to set SPOT MONITOR-2, -3 and -4.

  • FULL: The main monitor shows a single-screen display when an alarm is detected.
  • MULTI16*: The main monitor shows a 16-screen display when an alarm is detected.
  • MULTI9*: The main monitor shows a 9-screen display when an alarm is detected.
  • NC*: The main monitor display does not change when an alarm is detected. * The DOUBLE ALARM display will disappear.

ALARM SET-3

Page 65 of the Fisher MPX-CD163 user manual — ALARM SET-4
Page 65 · click to enlarge
Page 65

ALARM SET-4

ALARM SET SETTINGS

ACTIVE REC setting (default setting: OFF)

The ACTIVE REC setting can be used to give priority to alarm images when recording images. You can set the type of alarms to be recorded and the recording method for recording alarm images.

Example: To record both external and

Use the cursor button to select AL. REC. “EXT.”, and then press the setting buttons to select to “EXT. OR M. SENSOR”.

+ – 4

motion sensor alarm images in MODE2 (See page 65.)

(ACTIVE REC.SET)

The MAIN MENU screen will be displayed.

AL.REC.EXT.OR M.SENSOR REC.MODE MODE1

(MAIN MENU)

Display examples:

  • EXT.: Only external alarms will be recorded.
  • EXT. OR M.SENSOR: Both external alarms and motion sensor alarms will be recorded.
  • M.SENSOR: Only motion sensor alarms will be recorded.

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Use the cursor button to select REC. MODE “MODE1”, and then press the setting buttons to set to “MODE2”.

Use the cursor button to select “ALARM SET” and then press the NEXT button.

+ – 5

The ALARM SET screen will be displayed.

(ACTIVE REC.SET)

(ALARM SET)

AL.REC.EXT.OR M.SENSOR REC.MODE MODE2

ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF

Display examples:

  • MODE1: (See page 65.)
  • MODE2: (See page 65.)
  • ONLY: (See page 66.)

Use the cursor button to select ACTIVE REC. “OFF”, use the setting buttons to select “ON”, and then press the NEXT button.

The ACTIVE REC. SET screen will be displayed.

When an external alarm occurs, the alarm images will be recorded according to the MODE2 settings.

(ALARM SET)

ALARM OFF ACTIVE REC. ON * MOTION SENSOR OFF VIDEO LOSS OFF

ALARM SET-4

Display examples:

  • ON: Alarm images are recorded.
  • OFF: Alarm images are not recorded.
  • Please note that if the ALARM SET setting DURATION is set to NC, alarm images will continue to be recorded until the alarm is canceled with the camera select button. (See page 62.)
  • If an ALARM SET setting is set to OFF, the duration of active alarm recording will be fixed at 10 seconds. RETRIGGER will also be OFF. (See page 61.)
Page 66 of the Fisher MPX-CD163 user manual — ALARM SET-5
Page 66 · click to enlarge
Page 66

ALARM SET SETTINGS

Display examples:

  • MODE1: Recording alternates between images from the cameras where an alarm has occurred and images from all cameras that are connected. If alarms have occurred at more than one camera, images from the cameras where an alarm has occurred and images from all cameras are alternately recorded one image at a time.
  • Recording pattern if an alarm occurs at camera 2
  • Recording pattern if alarms occur at two or more cameras (e.g. cameras 2 and 4)
  • MODE2: Recording alternates between images from the cameras where an alarm has occurred and images from all cameras that are connected. If alarms have occurred at more than one camera, one image from each the cameras where an alarm has occurred is recorded first, and then one image from among all of the cameras connected is recorded.
  • Recording pattern if an alarm occurs at camera 2
  • Recording pattern if alarms occur at two or more cameras (e.g. cameras 2 and 4)

ALARM SET-5

Page 67 of the Fisher MPX-CD163 user manual — Playing back automatically switching images
Page 67 · click to enlarge
Page 67
Page 67 of the Fisher MPX-CD163 user manual — Playing back automatically switching images
Page 68 of the Fisher MPX-CD163 user manual — ALARM SET-7
Page 68 · click to enlarge
Page 68

ALARM SET-7

ALARM SET SETTINGS

MOTION SENSOR setting (default setting: OFF)

Example: To record images detected by the

motion sensor for the timer setting duration 1 Set the TIMER setting in the CLOCK SET menu to

To display motion sensors on each camera image and make settings for intruder detection. The motion sensors work as shown below.

“ON”, make the settings for TIMER-A and TIMER-B in the TIMER SET menu, and then select MOTION SENSOR and close the CLOCK SET screen.

AAAA BBBB

The MAIN MENU screen will be displayed.

CAMERA NO.01 T-1 LEVEL:OFF MODE:A

(MAIN MENU)

3 5 4 6

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

  • 1 Motion sensor off status When the cursor button is pressed, the cursor moves. 2 Sensor setting When the setting buttons are pressed, the setting changes to “ A ”, “ B ” or “ – ”. Set to “ A ” or “ B ” in accordance with the desired sensor detection position. 3 Camera display When the camera select button is pressed, the camera number changes. Use the camera select button to select cameras that are set for motion sensor alarms. 4 Setting motion sensor operating times Use timer settings to select specified time zones (T-1 to 4). This will enable an alarm to be detected by motion sensors with specified sensitivities only in the selected time zones (See page 36). 5 Motion sensor sensitivity setting
  • This sets the sensor sensitivity. 1, 2, 3, 4 ... (the higher the number, the lower the sensitivity), OFF 6 Motion sensor detection setting
  • A: A motion sensor alarm is generated when a moving object is detected at A.
  • A AND B: When an object is detected touching both sensors at point A and point B, a motion sensor alarm will be triggered.
  • A AND NB: With point A aligned on an important item (object) and point B aligned on a non-moving object, a motion sensor alarm will be triggered when the object at point A is detected, without reacting to changes such as the brightness of the whole screen.
  • B TO A: A motion sensor alarm will be triggered if there is any change in the movement of a subject passing from point A to point B.
  • C: A motion sensor alarm is generated when the whole screen area changes uniformly. This results in a reaction at times such as when the camera is sprayed with something. (Sensor settings are not required.)

Use the cursor button to select “ALARM SET” and then press the NEXT button.

The ALARM SET screen will be displayed.

(ALARM SET)

ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS OFF

Use the cursor button to select MOTION SENSOR “OFF”, press the setting buttons to change the setting to “ON”, and then press the NEXT button.

The motion sensor alarm setting screen will be displayed.

(ALARM SET)

ALARM OFF ACTIVE REC. OFF MOTION SENSOR ON * VIDEO LOSS OFF

Press camera select button 5.

The image from camera 5 appears and T-1 flashes.

CAMERA NO.05 T-1 LEVEL:OFF MODE:A

ALARM SET-7

Page 69 of the Fisher MPX-CD163 user manual — ALARM SET-8
Page 69 · click to enlarge
Page 69

ALARM SET-8

ALARM SET SETTINGS

Use the cursor button to move the cursor to the middle of the screen, and then press the setting buttons so that “A” is displayed.

VIDEO LOSS setting (default setting: OFF)

6 + –

If the camera image disappears because of a sudden accident or some other reason (so that image input stops), this sets whether the image that appeared immediately before the signal was lost is displayed as a still image or whether a test pattern is displayed. Example: To set a test pattern for the image

Set so that “A” is displayed in the middle of the screen.

A

when there is a VIDEO LOSS 1 Press the MENU button, use the cursor button to

CAMERA NO.05 T-1 LEVEL:OFF MODE:A

select “ALARM SET” and then press the NEXT button.

7 Use the cursor button to select “T-1”, and then

The ALARM SET screen will be displayed.

press the setting buttons to select “T-2”.

Use the cursor button to select VIDEO LOSS “OFF”, and then use the setting buttons to change to “TEST”.

CAMERA NO.05 T-2 LEVEL:OFF MODE:A 2

+ – 2

8 Use the cursor button to select LEVEL “OFF”, and

(ALARM SET)

then specify a sensitivity of “2” with the setting buttons.

ALARM OFF ACTIVE REC. OFF MOTION SENSOR OFF VIDEO LOSS TEST

CAMERA NO.05 T-2 LEVEL:2 MODE:A 2

Display examples:

9 Use the cursor button to select “MODE”, and then

  • OFF: When the video signal is lost, a blank screen is displayed.
  • FREEZE: The image displayed immediately before the video signal was lost is displayed as a still image.
  • TEST: When the video signal is lost, a test pattern is displayed.

press the setting buttons to select “A”.

CAMERA NO.05 T-2 LEVEL:2 MODE:A 2

  • This completes the setting. The display will return to the camera image screen.
  • When an intruder comes into the middle of the camera 5 image, an alarm will be generated.

Note:

  • If no cameras are connected, “ NO VIDEO ” is displayed. In this case, the video loss operation does not occur. However, if the power is turned off when a video signal is being input, the condition immediately before the video signal was lost is detected and video loss operation occurs.
  • A still image or a test pattern is displayed during video loss operation, but the recording device will record a test pattern until the alarm is reset or the image returns to normal.
  • Even if a still image is set to be displayed during video loss operation, a test pattern will appear if the screen is switched or automatic switching display has been set.

ALARM SET-8

--

Page 70 of the Fisher MPX-CD163 user manual — ALARM SET-9
Page 70 · click to enlarge
Page 70

ALARM SET-9

ALARM SET SETTINGS

Resetting an alarm

When images from the camera where the alarm was detected are appearing in a single-screen display

Press the camera select button for the camera that is being shown in the single-screen display.

The alarm will then be canceled.

When images from the camera where the alarm was detected are displayed in a multiple-screen

Press the camera select button for the camera that is showing the alarm.

The alarm images will appear in a single-screen display.

Press the camera select button again.

The alarm will then be canceled.

ALARM SET-9

Page 71 of the Fisher MPX-CD163 user manual — (SEQURITY LOCK SET)
Page 71 · click to enlarge
Page 71

SECURITY SET SETTINGS

Fisher MPX-CD163 — SECURITY SET SETTINGS diagram (page 71)
Fig. 47

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

You can set a security lock for the multiplexer to lock all button operations and menu operations in order to prevent mis-operations from being carried out when camera images are being displayed or video images are being played back.

To set SECURITY LOCK for all operating buttons

This lets you set a 4-digit code number to use for locking menu screen settings. Example: To register code numbers 1, 2, 3, 4

Use the cursor button to select OPERATION “CODE 1111”, and then press camera select buttons 1, 2, 3 and 4.

The MAIN MENU screen will be displayed.

(MAIN MENU)

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

(SEQURITY LOCK SET)

OPERATION CODE 1111 LOCK OFF

(SEQURITY LOCK SET)

Use the cursor button to select “SECURITY SET” and then press the NEXT button.

OPERATION CODE 1234 LOCK OFF

code number.

The SECURITY LOCK SET screen will be displayed.

Use the cursor button to select OPERATION “LOCK OFF”, use the setting buttons to select “ON”, and then press the MENU button.

(SEQURITY LOCK SET)

OPERATION CODE 1111 LOCK OFF

SETUP CODE 1111 LOCK OFF

The display will return to the camera image screen, and all button operations will be locked.

(SEQURITY LOCK SET)

OPERATION CODE 1234 LOCK OFF

(SEQURITY LOCK SET)

OPERATION CODE 1234 LOCK ON

Page 72 of the Fisher MPX-CD163 user manual — SETUP CODE 4321 LOCK ON
Page 72 · click to enlarge
Page 72

SECURITY SET SETTINGS

To cancel the locking of all operating buttons

Use the camera select buttons to re-enter the code number (example: 1234) that was entered under OPERATION “CODE”.

(OPERATION)

Press any single button.

A buzzer will sound and the code number request message will appear.

The buzzer will sound, the lock will be canceled and the camera images will be displayed.

SECURITY CODE SECURITY CODE SECURITY CODE

SECURITY CODE SECURITY CODE ¤¤¤¤ ¤¤¤¤ SECURITY CODE ¤¤¤¤

number request message will disappear after 10 seconds.

SETUP setting

This lets you set a 4-digit code number to use for locking menu screen settings. Example: To register code numbers 4, 3, 2, 1

Use the cursor button to select SETUP “CODE 1111”, and then press camera select buttons 4, 3, 2 and 1.

To cancel the locking of the MENU button

(SET UP)

A buzzer will sound and a code number request message will appear.

code number.

SETUP CODE 1111 LOCK OFF

SECURITY CODE SECURITY CODE SECURITY CODE

SETUP CODE 4321 LOCK OFF

number request message will disappear after 10 seconds.

Use the camera select buttons to re-enter the code number (example: 4321) that was entered under SETUP “CODE”.

Use the cursor button to select SETUP “LOCK OFF”, use the setting buttons to select “ON”, and then press the MENU button.

The buzzer will sound and the lock will be canceled.

The menu screen settings are now locked.

MENU + – SETUP CODE 4321 LOCK OFF

SECURITY CODE SECURITY CODE ¤¤¤¤ ¤¤¤¤ SECURITY CODE ¤¤¤¤

SETUP CODE 4321 LOCK ON

Notes common to SECURITY LOCK:

  • If both the SETUP lock and the OPERATION lock are applied at the same time, the code number request message will still appear when the MENU button is pressed. If you enter the SETUP code number at this time, both locks will be canceled, but if you enter the OPERATION code number, only the OPERATION lock will be canceled, and the SETUP lock will remain applied.
  • After the locks have been released and operations are enabled, if you press and hold the LIVE button for three seconds when a camera image is being viewed, the locking will be applied once more with the menu in the mode that was set.
  • During playback, press the VCR button to engage the lock.
Page 73 of the Fisher MPX-CD163 user manual — (CONTROL SET)
Page 73 · click to enlarge
Page 73

CONTROL SET SETTINGS

Fisher MPX-CD163 — CONTROL SET SETTINGS diagram (page 73)
Fig. 48
  • Set a data transfer rate for serial communication.
  • Set whether alarm information will be sent or not.
  • Set whether RS-485 or RS-232C will be used for serial communication.

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

Make dome-type camera settings to enable power and signal control with a RS-485 dedicated coaxial cable.

The following settings must be made if using the RS-232C connector or the RS-485 connector for serial communication between a computer or a system controller and the multiplexer.

CONTROL SET settings

+ – 4

Use the cursor button to select DATA SPEED “19200”, and then press the setting buttons to set the communication speed.

Settings for serial communication between the computer and system controller using RS-232C connectors and RS-485 connectors.

This sets the data communication speed for serial communication.

The MAIN MENU screen will be displayed.

(MAIN MENU)

(CONTROL SET)

DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

CAMERA CONTROL SANYO *

2400, 4800, 9600, 19200

Use the cursor button to select “CONTROL SET” and then press the NEXT button.

+ – 5

Use the cursor button to select ALARM SEND “ON”, and then press the setting buttons to select the alarm data.

The CONTROL SET screen will be displayed.

(CONTROL SET)

(CONTROL SET)

DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C

DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C

CAMERA CONTROL SANYO *

+ – 3

Use the cursor button to select RS232C/RS485 “RS232C”, and then press the setting buttons to select “RS232C” or “RS485”

Display examples:

  • OFF: Alarm data is not transmitted.
  • ON: Alarm data is transmitted.

(CONTROL SET)

DATA SPEED 19200 ALARM SEND ON RS232C/RS485 RS232C

Display examples:

This completes the settings.

  • When RS-232C is selected Use a commercially available RS-232C cable for the connection between the RS-232C connectors of this unit and a personal computer.
  • When RS-485 is selected Use a modular cable or a twisted-pair cable for the connections between the RS-485 control connectors of this unit, the system controller and the digital video recorder.
Page 74 of the Fisher MPX-CD163 user manual — CONTROL SET-1
Page 74 · click to enlarge
Page 74

CONTROL SET-1

CAMERA CONTROL setting

To control the dome-type camera

This describes the settings and methods of operation when connecting a dome-type camera for which the power and signal can be controlled through a coaxial cable to the camera video input connector. The two methods of operation are: direct control using the control buttons on this unit and operation from the system controller (using the RS-485 connector).

from the system controller through this unit.

Use the cursor button to select CAMERA CONTROL “SANYO”, and then press the NEXT button.

The CAMERA CONTROL SET screen will be displayed.

To control a dome-type camera with

(CONTROL SET)

this unit

DATA SPEED 19200 ALARM SEND OFF RS232C/RS485 RS232C

Press the LIVE button.

LIVE 1

To display will return to the normal screen.

CAMERA CONTROL SANYO *

Display examples:

  • SANYO: Select when a coaxial cable camera manufactured by Sanyo is connected.
  • OTHER: Select when a coaxial cable camera manufactured by some other manufacturer is connected.

Press the camera select button (example: 2) for the connected dome-type camera.

The main monitor or spot monitor will change to a single-screen display.

Use the cursor buttons to select “OFF” for the number of a dome-type camera that is connected (example: 01).

operations are not available for signal-screen display on the main monitor while the dome-type camera image is being viewed.

(CAMERA CONTROL SET)

IN IN 01:OFF 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

3 To control the dome-type camera with the various

buttons of this unit

1 Cursor buttons: Enable pan and tilt operations 2 Setting buttons: Zoom in (+), zoom out (–) 3 Next screen button: Enables one-touch auto focus

+ – 3

Press the setting button and use the setting buttons once more to enter the address of the camera (example: 001).

While viewing, if you press and hold down the camera select button for about two seconds, the indicator will flash and the following camera adjustments will be enabled.

(CAMERA CONTROL SET)

IN IN 01:001 09:OFF 02:OFF 10:OFF 03:OFF 11:OFF 04:OFF 12:OFF 05:OFF 13:OFF 06:OFF 14:OFF 07:OFF 15:OFF 08:OFF 16:OFF

to make camera adjustments will be canceled after about ten seconds. For making adjustments, press the camera select button once more.

Note:

  • Enter the RS-485 control address for a dome-type camera that is connected to this unit.
  • When you press the setting button, OFF will change to 000 and you can then enter the address.
  • Addresses from 000 to 127 can be entered. The number will be incremented by pressing the + setting button and decremented by pressing the – setting button.

4 Cursor button (→): Open iris Cursor button (←): Close iris 5 Setting button (+): Manual focus Setting button (–): Manual focus

This completes the settings. Use the control buttons in the system controller “MULTIPLEXER” operating domain for controlling the dome-type cameras.

CONTROL SET-1

Page 75 of the Fisher MPX-CD163 user manual — (MAIN MENU)
Page 75 · click to enlarge
Page 75

ALARM DATA SETTINGS

1 Camera number Shows the camera number where the alarm was detected. 2 DATE Shows the date that the alarm was detected. 3 TIME Shows the time of day that the alarm was detected. 4 ITEM E: Indicates that an external alarm was detected. S: Indicates that a motion sensor alarm was detected. V: Indicates that a video loss was detected.

Fisher MPX-CD163 — ALARM DATA SETTINGS diagram (page 75)
Fig. 49

1 LANGUAGE * 2 CLOCK SET * 3 DISPLAY SET * 4 VCR SET * 5 ALARM SET * 6 SECURITY SET * 7 CONTROL SET * 8 ALARM DATA * (*:NEXT)

(ALARM DATA) 1/ 1 CAM DATE TIME ITEM 1 1 06-08 11:45 E 2 2 06-08 10:30 S 3 3 06-08 08:30 V

Alarm data can be displayed on the screen in the form of an alarm list. This can be used for purposes such as checking the alarm images that have been recorded by the recording device. Note: To display alarm information in the alarm list, you need to make the required ALARM settings (see page 62) and set “ALARM

LIST” to “ON”.

Displaying the alarm data list

(MAIN MENU)

The MAIN MENU screen will be displayed.

1 LANGUAGE ¤ 2 CLOCK SET ¤ 3 DISPLAY SET ¤ 4 VCR SET ¤ 5 ALARM SET ¤ 6 SECURITY SET ¤ 7 CONTROL SET ¤ 8 ALARM DATA ¤ (*:NEXT)

Use the cursor button to select “ALARM DATA” and then press the NEXT button.

(ALARM DATA) 1/ 1 CAM DATE TIME ITEM 1 1 06-08 11:45 E 2 2 06-08 10:30 S 3 3 06-08 08:30 V

The ALARM DATA screen will be displayed.

To display the next page of the alarm list, press the NEXT button.

(ALARM DATA) 2/ 3 CAM DATE TIME ITEM 9 4 06-08 05:30 E 10 7 06-08 03:00 S 11 10 06-08 02:15 V

The next page of the alarm list will then be displayed. Note: If the number of alarm entries reaches 100, the oldest entries will be

deleted and the newer entries will be displayed.

Page 76 of the Fisher MPX-CD163 user manual — RJ-11 connector specifications
Page 76 · click to enlarge
Page 76

INTERFACE SPECIFICATIONS

RS-232C

9-pin connector specifications

Fisher MPX-CD163 — 9-pin connector specifications diagram (page 76)
Fig. 50 · 9-pin connector specifications

Pin No. Signal Operation Signal direction 1 – – 2 RXD Receive data Computer → Multiplexer 3 TXD Transmit data Multiplexer → Computer 4 – – – 5 GND Ground – 6 – – – 7 RTS Request to send Multiplexer → Computer 8 – – – 9 – – –

5 4 3 2 1

9 8 7 6

Fisher MPX-CD163 — 9-pin connector specifications diagram (page 76)
Fig. 51 · 9-pin connector specifications

Mode Asynchronous Character length 8 bits Data transmit speed 2400, 4800, 9600, 19200 bps Parity None Stop bit 1

Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a response from the multiplexer, and then transmits the next byte of data. To start sending commands, an ON (F6) command is sent. The multiplexer will continue to receive commands until an OFF (F7) command is sent to stop. The multiplexer sends an ACK (OA) each time it receives a command. See Table 4 - Command Table on page 79.

RS-485

RJ-11 connector specifications

Fisher MPX-CD163 — RJ-11 connector specifications diagram (page 76)
Fig. 52 · RJ-11 connector specifications

Pin No. Pin A signals Pin B signals 1 Spare Spare 2 Spare Spare 3 Signal B Signal A 4 Signal A Signal B 5 Spare Spare 6 Spare Spare

Mode Asynchronous Character length 8 bits Data transmit speed 2400, 4800, 9600, 19200 bps Parity None Stop bit 1

A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special controller be used. Contact the place of purchase for further details on obtaining a special controller.

Page 77 of the Fisher MPX-CD163 user manual — OFF
Page 77 · click to enlarge
Page 77

INTERFACE SPECIFICATIONS

RS485 termination switch settings (RS485 TEAMINATE)

Termination setting

If several multiplexers are being connected together, termination settings must also be made.

  • Set the RS485 termination switch on the rear panel to ON , and set the termination switch of the last device in the series to ON .
  • Be sure to set the RS485 termination switches of all devices in between (devices other than the first and last in the series) to OFF . Note: If the termination settings are not correct, data will be

ON

Fisher MPX-CD163 — ON diagram (page 77)
Fig. 53

reflected by either end of the series and this will affect the transmission of other data, so that the data that is transmitted to each device will not be correct.

OFF

System controller · Termination switch · Time lapse VCR

Page 78 of the Fisher MPX-CD163 user manual — 3rd byte
Page 78 · click to enlarge
Page 78

INTERFACE SPECIFICATIONS

Multiplexer data status command STATUS SENSE (D7)

Fisher MPX-CD163 — Multiplexer data status command STATUS SENSE (D7) diagram (page 78)
Fig. 54 · Multiplexer data status command STATUS SENSE (D7)

Bit Bit details 3 Indicates the display channels and menu numbers for each display on the main monitor using 4 bits

(For serial connection) 2 0000: MAIN 1 0001: SUB 1 0 0010: SUB 2 0011: SUB 3 (Menu selection) 0001: Menu 1 MAIN MENU settings 0010: Menu 2 LANGUAGE settings 0011: Menu 3 CLOCK SET settings 0100: Menu 4 DISPLAY SET settings 0101: Menu 5 VCR SET settings 0110: Menu 6 ALARM SET settings 0111: Menu 7 SECURITY SET settings 1000: Menu 8 CONTROL SET settings 1001: Menu 9 ALARM DATA settings

When this command is sent by the computer, the multiplexer returns a 5-byte operating status code (Table 1).

d1 d2 d3 d4 d5 RXD TXD

D7

STATUS SENSE (D7) bit allocation (Table 1)

The 4th and 5th bytes are spare. 1st byte

Bit Bit details 7 Indicates LIVE and VCR

0. Live image mode 1: VCR playback mode 6 Indicates the main monitor display using 3 bits
0. Single-screen 5 001: 4-screen 4 010: Multiple-screen 011: Plus screen 100: Menu selection 101: Series 111: Standby 3 Indicates the display channels and menu numbers for each display on the main monitor using 4 bits

2nd byte

Fisher MPX-CD163 — 2nd byte diagram (page 78)
Fig. 55 · 2nd byte

(During single-screen) 2 0000: Channel 1 1 0001: Channel 2 0 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16* (During 4-screen) 0000: 4-screen (1, 2, 3, 4) 0001: 4-screen (5, 6, 7, 8) 0010: 4-screen (9, 10*, 11*, 12*) 0011: 4-screen (13*, 14*, 15*, 16*) (For multiple-screen) 0000: Single-screen 1000: 9-screen 1111: 16-screen* (For plus screen) 0000: Channel 1 0001: Channel 2 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*

4 Spare 0 3 Indicates the main monitor display status using 4 bits

0000: Normal display 2 0001: Automatic switching display 1 0010: Zoom display 0 0011: Still image 0100: Zoomed still image 0101: Still image zoomed 0110: Zoom position setting 0111: Still image zoom position setting

3rd byte

Bit Bit details 7 Indicates the currently- operating spot monitor using 2 bits

0. Spot monitor 1 6 01: Spot monitor 2 10: Spot monitor 3 11: Spot monitor 4

5 Spot monitor operation

1. Spot monitor operating

4 Spot monitor operation

0. Single-screen 1: Automatic switching display 3 Indicates the camera number for currentlyoperating spot monitor using 4 bits Indicates the spot monitor 1 camera number when the main monitor is operating

0000: Channel 1 2 0001: Channel 2 1 0010: Channel 3 0 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*

*: Command for MPX-CD163 only

Page 79 of the Fisher MPX-CD163 user manual — 5th byte
Page 79 · click to enlarge
Page 79

INTERFACE SPECIFICATIONS

Multiplexer commands ACK (0A)

4th byte

Fisher MPX-CD163 — Multiplexer commands ACK (0A) diagram (page 79)
Fig. 56 · Multiplexer commands ACK (0A)

Bit Bit details 7 Indicates the model number using 1 bit.

Returned when the multiplexer receives a command. NAK (0B)

0000: Older series (CD16, CD162) 6 0001: X-CD163 series 5 4 3 Spare 2 Spot monitor operation

Returned when the multiplexer does not receive a command. ALARM (BF)

When there is alarm input, an ALARM command is sent as a header, and after this the alarm data (Table 3) is sent using 1 byte. Alarm data (Table 3)

1 Indicates the number of spot monitors using 2 bits

0. 1 0 01: 2 10: 3 11: 4
Fisher MPX-CD163 — Multiplexer commands ACK (0A) diagram (page 79)
Fig. 57 · Multiplexer commands ACK (0A)

Bit Bit details 7 Indicates the type of alarm using 2 bits

0. No alarm input 6 01: External 10: Video loss 11: Motion sensor alarm 5 Spare 0 4 Spare 0 3 Indicates the camera number using 4 bits

ALARM STATUS SENSE (D5)

Returns the multiplexer external alarm status (Table 2) using 6 bytes

d1 d2 d3 d4 d5 d6 RXD TXD

D5

0000: Channel 1 2 0001: Channel 2 1 0010: Channel 3 0 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9 1001: Channel 10* 1010: Channel 11* 1011: Channel 12* 1100: Channel 13* 1101: Channel 14* 1110: Channel 15* 1111: Channel 16*

ALARM STATUS SENSE (D5) bit allocation (Table 2)

1st byte

2nd byte

Fisher MPX-CD163 — ALARM STATUS SENSE (D5) bit allocation (Table 2) diagram (page 79)
Fig. 58 · ALARM STATUS SENSE (D5) bit allocation (Table 2)

7 ALARM 8 ON 6 ALARM 7 ON 5 ALARM 6 ON 4 ALARM 5 ON 3 ALARM 4 ON 2 ALARM 3 ON 1 ALARM 2 ON 0 ALARM 1 ON

7 ALARM 16 ON* 6 ALARM 15 ON* 5 ALARM 14 ON* 4 ALARM 13 ON* 3 ALARM 12 ON* 2 ALARM 11 ON* 1 ALARM 10 ON* 0 ALARM 9 ON*

3rd byte

4th byte

*: Command for MPX-CD163 only

Fisher MPX-CD163 — 3rd byte diagram (page 79)
Fig. 59 · 3rd byte

7 SENSOR 8 ON 6 SENSOR 7 ON 5 SENSOR 6 ON 4 SENSOR 5 ON 3 SENSOR 4 ON 2 SENSOR 3 ON 1 SENSOR 2 ON 0 SENSOR 1 ON

7 SENSOR 16 ON* 6 SENSOR 15 ON* 5 SENSOR 14 ON* 4 SENSOR 13 ON* 3 SENSOR 12 ON* 2 SENSOR 11 ON* 1 SENSOR 10 ON* 0 SENSOR 9 ON*

5th byte

6th byte

Fisher MPX-CD163 — 5th byte diagram (page 79)
Fig. 60 · 5th byte

7 VIDEO LOSS 8 ON 6 VIDEO LOSS 7 ON 5 VIDEO LOSS 6 ON 4 VIDEO LOSS 5 ON 3 VIDEO LOSS 4 ON 2 VIDEO LOSS 3 ON 1 VIDEO LOSS 2 ON 0 VIDEO LOSS 1 ON

7 VIDEO LOSS 16 ON* 6 VIDEO LOSS 15 ON* 5 VIDEO LOSS 14 ON* 4 VIDEO LOSS 13 ON* 3 VIDEO LOSS 12 ON* 2 VIDEO LOSS 11 ON* 1 VIDEO LOSS 10 ON* 0 VIDEO LOSS 9 ON*

*: Command for MPX-CD163 only

Page 80 of the Fisher MPX-CD163 user manual — Command Table (Table 4)
Page 80 · click to enlarge
Page 80

INTERFACE SPECIFICATIONS

Command Table (Table 4)

The following table shows all of the commands that can be processed by the multiplexer. If a command sent does not correspond to a multiplexer function, the command is received but no operation is carried out.

Fisher MPX-CD163 — Command Table (Table 4) diagram (page 80)
Fig. 61 · Command Table (Table 4)

*: Command for MPX-CD163 only **: Command for RS-485 only

Page 81 of the Fisher MPX-CD163 user manual — SPECIFICATIONS
Page 81 · click to enlarge
Page 81

SPECIFICATIONS

Signal formatBased on NTSC color signal standard
Camera signal input synchronizationAsynchronous

Camera video input connectors: VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 16 Control signal superimposed when camera operating

(MPX-CD93BNC connector x9)

Camera video output connectors: Throughput of each input, 1.0 Vp-p/75 Ω, BNC connector x 16 (MPX-CD93: BNC connector x9)

  • Composite input : VS/VBS, 1.0 Vp-p/75 Ω , BNC connector x 1
  • S-Video input connector : Separate YC signals, DIN connector (S terminal) x 1

Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω, unbalanced • Digital input connector: RJ-45 x 1

  • Composite output : VS/VBS, 1.0 Vp-p/75 Ω , BNC connector x 1
  • S-Video output connector : Separate YC signals, DIN connector (S terminal) x 1

Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω, unbalanced • Digital input connector: RJ-45 x 1

Main monitor output connector (MAIN MONITOR): VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1

Camera live image or VCR playback image output: single-screen, automatic switching image, multiple-screen • S-Video output connector: Separate YC signals, DIN connector (S terminal) x 1

Y signal1.0 Vp-p/75 Ω , unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω , unbalanced

Spot monitor output connectors (SPOT MONITOR 1 - 4): VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 4

Camera live imagesingle-screen (Same image as main monitor selectable using menu/SPOT MONITOR 1 only)
  • Remote control input (R1, R2) : 2-wire type with resistance-based identification system
  • Alarm output (AL) : 5 V DC, 5.7 k Ω (Low output)
  • Switch input (SW) : Low input, for input signal from SW OUT of timelapse VCR/real time VCR (as per this manufacturer
Alarm input connectorsNo voltage, make-contact switch input x 16 (Low input) (MPX-CD93: BNC connector x9)
Sensor alarm output connectorAlarm output x 16 (low output, normally open) (MPX-CD93: BNC connector x9)
RS-485 control connectorRJ-11 type: 2 connectors (A/B), Push-lock type: 3 connectors (A, B, Ground)
RS-232C connector9-pin D-SUB

Automatic screen switching timing: Available in single-screen and quad mode, with interval selectable from 1 – 30 sec.

Monitor on-screen displayTitle (up to 10 characters), date, time selectable
Show 5 more labels / short text on this page
VCR input connector · VCR output connector · Control connector · specifications) · Menu settings
Page 82 of the Fisher MPX-CD163 user manual — ATTENTION
Page 82 · click to enlarge
Page 82

SANYO INDUSTRIAL MULTIPLEXER WARRANTY

OBLIGATIONS

In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user’s expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service Centers may be obtained by calling the toll-free number listed below.

For product operation, authorized service center referral, service assistance or problem resolution, call

CUSTOMER INFORMATION 1-800-421-5013

Weekdays 8:30 AM – 5:00 PM Pacific Time For accessories and/or parts, call

PARTS ORDER INFORMATION 1-800-726-9662

Weekdays 8:30 AM – 5:00 PM Pacific Time

THIS WARRANTY IS VALID ONLY ON SANYO PRODUCTS PURCHASED OR RENTED IN THE UNITED STATES OF AMERICA, EXCLUDING ALL U.S. TERRITORIES AND PROTECTORATES. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL RETAIL PURCHASER OR END-USER. THE ORIGINAL DATED BILL OF SALE, SALES SLIP OR RENTAL AGREEMENT MUST BE SUBMITTED TO THE AUTHORIZED SANYO SERVICE CENTER AT THE TIME WARRANTY SERVICE IS REQUESTED.

Subject to the OBLIGATIONS above and EXCLUSIONS below, SANYO Fisher Company warrants this SANYO product against defects in materials and workmanship for the periods specified below. SFC will repair or replace (at its option) the product and any of its parts which fail to conform to this warranty. The warranty period commences on the date the product was first purchased or rented at retail.

LABOR PARTS

3 YEARS 3 YEARS

EXCLUSIONS

This warranty does not cover (A) the adjustment of customer-operated controls as explained in the appropriate model’s instruction manual, or (B) the repair of any product whose serial number has been altered, defaced or removed. This warranty shall not apply to the cabinet or cosmetic parts, batteries or routine maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product after repair. This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including, but not limited to, any malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear. The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any other obligation or liability. SFC DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED, WITH REGARD TO THIS PRODUCT (INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS). IN NO EVENT SHALL SFC BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE OWNERSHIP OR USE OF THIS PRODUCT OR FOR ANY DELAY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL. SFC’S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER, ARISING OUT OF OR IN CONNECTION WITH THE SALE, USE OR OWNERSHIP OF THIS PRODUCT INCLUDING WARRANTOR’S NEGLIGENCE, ALLEGED DAMAGED OR DEFECTIIVE GOODS, WHETHER SUCH DEFECTS ARE DISCOVERABLE OR LATENT, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT.

ATTENTION

For your protection in the event of theft or loss of this product, please fill in the information below for you own personal records.

Model No Serial No (Located on back or bottom side of unit.)

Date of Purchase Purchase Price

Where Purchased

Page 83 of the Fisher MPX-CD163 user manual — Multiplexeur Français F
Page 83 · click to enlarge
Page 83

Multiplexeur Français F

Ask about the Fisher MPX-CD163

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fisher MPX-CD163

Be the first to ask — other owners or our team will answer.

Original document

Fisher MPX-CD163 manual PDF

252 pages·8.5 MB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…