EN
Fantom Vacuum logo
Official user manual

Fantom Vacuum FS801

6 pages·580 KB·Vacuum Cleaner·PDF·ENDEFRITNLJA
Fantom Vacuum FS801
Table of Contents 62 sections FANTOM · OWNER’S MANUAL · Model FS801 · your name, complete address and phone number with a note giving · … ShowHide
FANTOMp.1OWNER’S MANUALp.1Model FS801p.1your name, complete address and phone number with a note givingp.1purchase information, model number and what you believe is the problemp.1not covered by your warranty). Mark the outside of your packagep.1“ATTENTION CUSTOMER SERVICE”. We are constantly striving to improvep.1our products, therefore the specifications contained herein are subject top.1ONE (1) YEAR LIMITED WARRANTYp.1IMPORTANT SAFETY INSTRUCTIONS ORDERING REPLACEMENT DUST CUP FILTERSp.2be observed, including the following: TO ORDER REPLACEMENT FILTERSp.2OR FOR TECHNICAL SUPPORTp.2for Model FS801 To reduce the risk of fire, electric shock, orp.2Please Note:p.2Important:p.2SAVE THESE INSTRUCTIONSp.2For Household Use Onlyp.2Technical Specificationsp.3WILL NOT PICK-UPp.3NOT PICK-UP ORp.3SUCTION POWERp.3DUST ESCAPINGp.3VACUUM, HOSEp.3VACUUM WILLp.3NOT OPERATEp.3TURBO BRUSHp.3OR BRUSHESp.3DOES NOTp.3ROTATE ORp.3ROTATESp.3IS WEAKp.3SLOWLYp.3Changing & Cleaning the Pre-p.4OPERATING INSTRUCTIONS PRECAUTIONARY MEASURESp.4Motor Filterp.4ATTACHING THE FLOOR BRUSHp.5ATTACHING THE HOSE TO THEp.5TO THE MAIN UNITp.5MAIN UNITp.5EXTENDING THE TELESCOPICp.5INSERTING THE TELESCOPICp.5TUBE INTO THE MAIN UNITp.5TUBEp.5HEPAp.5Emptying the Dust Cup Containerp.5and Cleaning / Changing the Non-p.5Woven Pre-Filter, HEPA Filter &p.5Debris Screenp.5Cleaning Air Driven Turbo Brushp.6Using The Unit With Air Drivenp.6= OFF Attaching the Air Driven Turbop.6Air Driven Turbo Brushp.6Brush to the Flexible Hosep.6USING THE UNIT AS A HANDp.6Intelli-Sense TM Filter Monitorp.6WARNINGp.6VACUUMp.6USING THE UNIT AS AN UPRIGHTp.6WINDING & UNWINDING THEp.6ON/OFF SWITCHp.6POWER CORDp.6= ONp.6
Page 1 of the Fantom Vacuum FS801 user manual — not covered by your warranty). Mark the outside of your package
Page 1 · click to enlarge
Page 1
Fantom Vacuum FS801 — FANTOM diagram (page 1)
Fig. 1
Fantom Vacuum FS801 — FANTOM diagram (page 1)
Fig. 2
Fantom Vacuum FS801 — FANTOM diagram (page 1)
Fig. 3

94 Main Mill Street, Door 16 Plattsburgh, NY 12901

Tel.: 1 (800) 275-9251

www.fantom.com Printed in China 11

FANTOM

OWNER’S MANUAL

Model FS801

120V., 60Hz., 10 Amps

negligent handling or damage due to faulty packaging or mishandling in transit.

FANTOM warrants this product to be free from defects in material and

workmanship for a period of one (1) year from the date of the original purchase,

when utilized for normal household use, subject to the following conditions,

If your appliance fails to operate properly while in use under normal household

If the appliance is found to be defective in material or workmanship, FANTOM will

repair or replace it free of charge. Proof of purchase date and $ 9.95 to cover the

Non-durable parts including, without limitation, filters, brushes and electrical parts

The liability of FANTOM is limited solely to the cost of the repair or replacement of

the unit at our option. This warranty does not cover normal wear of parts and does

not apply to any unit that has been tampered with or used for commercial

purposes. This limited warranty does not cover damage caused by misuse, abuse,

This warranty does not cover damage or defects caused by or resulting from

damages from shipping or repairs, service or alterations to the product or any of

its parts, which have been performed by a repair person not authorized by

This warranty is extended to the original purchaser of the unit and excludes all

other legal and/or conventional warranties. The responsibility of FANTOM if any,

is limited to the specific obligations expressly assumed by it under the terms of the

limited warranty. In no event is FANTOM liable for incidental or consequential

damages of any nature whatsoever. Some states do not permit the exclusion or

limitation of incidental or consequential damages, so the above may not apply to

This warranty gives you specific legal rights, and you may also have other rights

*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with

your name, complete address and phone number with a note giving

purchase information, model number and what you believe is the problem

with item. We recommend you insure the package (as damage in shipping is

not covered by your warranty). Mark the outside of your package

“ATTENTION CUSTOMER SERVICE”. We are constantly striving to improve

our products, therefore the specifications contained herein are subject to

ONE (1) YEAR LIMITED WARRANTY

conditions within the warranty period, contact FANTOM customer service at

1 (800) 275-9251 for information on returning the appliance and accessories.

which normally require replacement are specifically excluded from warranty.

Fantom Vacuum FS801 — not covered by your warranty). Mark the outside of your package diagram (page 1)
Fig. 4 · not covered by your warranty). Mark the outside of y…

cost of return shipping and handling must be included. *

which vary from state to state.

exclusions and exceptions.

change without notice.

FANTOM.

you.

Model FS801

Page 2 of the Fantom Vacuum FS801 user manual — For Household Use Only
Page 2 · click to enlarge
Page 2

Make sure that ALL filters have been completely air dried for 24 hours before

The HEPA Filter is washable. It should, however, be replaced every six (6)

however be replaced every three (3) months to ensure peak performance of

IMPORTANT SAFETY INSTRUCTIONS ORDERING REPLACEMENT DUST CUP FILTERS

Both the Pre-Motor and Post Motor Filters are washable. They should

Call1 (800) 275-9251 Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time

be observed, including the following: TO ORDER REPLACEMENT FILTERS

OR FOR TECHNICAL SUPPORT

months to ensure peak performance of your vacuum.

Or visit our website:

www.fantom.com

for Model FS801 To reduce the risk of fire, electric shock, or

Rev. 01/04B 1 10

re-installing back in the vacuum.

Please Note:

your vacuum.

Important:

be taken to arrange the cord so that the cord

not use with any opening blocked. Keep free

  • Use only as described in this manual. Use

less amperage may overheat. Care should

of dust, lint, hair and anything else that may

damage to the motor and possible injury to

in when unattended. Unplug the electrical

cord when not in use and before servicing.

  • Do not allow to be used as a toy. Close

sharp edges or corners. Keep cord away

  • Use only extension cords UL-rated or cUL

at 15 amperes. Extension cords rated for

  • Do not put any objects into openings. Do
  • Store your appliance indoors in a cool, dry

the user. Correct voltage is listed on rating

SAVE THESE INSTRUCTIONS

When using your FANTOM Stick Vac basic safety precautions should always

  • Do not pull cord, use cord as a handle,

close a door on cord, or pull cord around

  • Turn off all controls as applicable before
  • Do not handle plug or vacuum with wet

openings away from your face and body.

polarized plug (one blade is wider than the other). This plug will

fit in a polarized outlet only one way. If the plug does not fit fully

  • Do not leave the Stick Vac plugged
  • Keep end of hose, wands and other
  • Using improper voltage may result in

qualified electrician to install the proper outlet. Do not modify

in the outlet, reverse the plug. If it still does not fit, contact a

cannot be pulled or tripped over.

unplugging from electrical outlet.

hands or operate without shoes.

  • Keep your work area well lit.

For Household Use Only

  • Use only on dry surfaces.

children, pets or plants.

from heated surfaces.

reduce air flow.

accessories.

area.

label.

injury:

7. Do not operate the system with a damaged

cord or plug, or if the appliance or any other

repair the Stick Vac. Return the vacuum to

can cause a risk of electrical shock or injury

combustible liquids such as gasoline or use

smoking such as cigarettes, matches or hot

and repair. Incorrect re-assembly or repair

appliance being used by or near children.

Do not leave the system unattended while

household use. Follow all user instructions

2. Use the system only for its intended use.
3. To protect against a risk of electric shock,

do not immerse any part of the system in

5. Do not allow cord to touch hot surfaces.

FANTOM (see warranty) for examination

9. Keep hair, loose clothing, fingers and all
11. Do not pick up anything that is burning or

the plug in any way.

1. Read all instructions before using your

part of the system has been dropped or

shock, do not disassemble or attempt to

to persons when the Stick Vac is used.

8. Close supervision is necessary for any
12. Use extra care when cleaning on stairs.

outlet; instead, grasp plug and pull to

damaged. To avoid the risk of electric

parts of body away from opening and

4. Never yank cord to disconnect from
10. Do not use to pick up flammable or

in areas where they may be present.

13. Do not use the vacuum without the
14. This appliance is intended only for
6. Do not run appliance over cord.

FANTOM Stick Vac.

water or other liquids.

HEPA filter in place.

in this manual.

moving parts.

disconnect.

connected.

ashes.

only manufacturer’s recommended

Page 3 of the Fantom Vacuum FS801 user manual — IS WEAK
Page 3 · click to enlarge
Page 3
Fantom Vacuum FS801 — Technical Specifications diagram (page 3)
Fig. 5 · Technical Specifications
10. Exhaust Filter Cover 11. On/Off Switch 12. Power Cord 13. Floor Brush Release Button 14. Floor Brush 15. Crevice Tool 16. Dusting Brush 17. Telescopic Tube Release Button
5. Dust Cup Release Button 1
18. Dust Cup Release Button 2 19. Cord Hook Release 20. Hose Connector 21. Air Driven Turbo Brush 22. Shoulder Strap (not shown)
7. Dust Cup (Container)
9. Intelli-Sense TM Filter
6. Dust Cup Handle
2. Telescopic Tube
3. Locking Button
4. Flexible Hose
1. Hand Grip
8. Main Unit
Fantom Vacuum FS801 — Technical Specifications diagram (page 3)
Fig. 6 · Technical Specifications

Voltage: 120V., 60Hz. Power: 10 Amps *Illustration may differ from actual product.

Technical Specifications

PROBLEMPOSSIBLE REASONPOSSIBLE SOLUTION VACUUM WILL NOT OPERATE1. Power cord not firmly plugged into outlet. 2. No power in wall outlet. 3. Needs servicing. 4. Thermostat has tripped.1. Plug unit in firmly. 2. Check fuse or breaker. Replace fuse/reset breaker. 3. Call 1-800-275-9251. 4. Turn the unit off and unplug from outlet. Allow unit to cool down, then restart. VACUUM WILL NOT PICK-UP OR SUCTION POWER IS WEAK1. Dust cup is full. 2. Unit clogged. 3. HEPA Filter needs cleaning or replacing. 4. Debris screen needs cleaning. 5. Filters need cleaning.1. Empty and clean dust cup. 2. Turn unit off and unplug from wall outlet. Remove Dust Cup Filter and check for object(s) in air duct and remove. 3. Clean or replace HEPA Filter. 4. Clean debris screen. 5. Clean filters. TURBO BRUSH DOES NOT ROTATE OR ROTATES SLOWLY1. Dust cup is full. 2. Rotating brush or elbow is obstructed. 3. Belt is broken. 4. Hose obstructed. 5. Debris screen is clogged. 6. Filters need cleaning.1. Empty dust cup. 2. Clear obstructions. 3. Call 1-800-275-9251. 4. Clear obstruction. 5. Clean debris screen. 6. Clean filters. DUST ESCAPING FROM VACUUM1. Dust cup is full. 2. Dust Cup is not installed correctly.1. Empty and clean dust cup. 2. Review Dust Cup instructions. VACUUM, HOSE OR BRUSHES WILL NOT PICK-UP1. Hose clogged. 2. Dust cup is full.1. Remove hose and/or brushes. Remove obstruction from hose and /or brush. 2. Empty and clean dust cup.
Fantom Vacuum FS801 — Technical Specifications diagram (page 3)
Fig. 7 · Technical Specifications
2. Dust Cup is not installed correctly. 1. Empty and clean dust cup.

filters.

1. Power cord not firmly plugged into
3. HEPA Filter needs cleaning or
4. Debris screen needs cleaning.
2. Rotating brush or elbow is
5. Debris screen is clogged.
2. No power in wall outlet.
4. Thermostat has tripped.
5. Filters need cleaning.
6. Filters need cleaning.
3. Needs servicing.
4. Hose obstructed.

automatically turn the unit off. Should

1. Dust cup is full.
1. Dust cup is full.
3. Belt is broken.

FROM VACUUM 1. Dust cup is full.

1. Hose clogged.
2. Dust cup is full.

with a motor protective thermostat. If

for some reason the vacuum cleaner

  • Check the source of overheating problem. (i.e. clogged hose or
2. Unit clogged.

should overheat, the thermostat will

replacing.

obstructed.

  • Push the On/Off button once.
  • Disconnect the plug from the power source.

outlet.

WILL NOT PICK-UP

NOT PICK-UP OR

SUCTION POWER

DUST ESCAPING

VACUUM, HOSE

VACUUM WILL

NOT OPERATE

VACUUM WILL

TURBO BRUSH

OR BRUSHES

DOES NOT

ROTATE OR

ROTATES

this occur:

IS WEAK

SLOWLY

Monitor · filter)

Page 4 of the Fantom Vacuum FS801 user manual — Motor Filter
Page 4 · click to enlarge
Page 4
Fantom Vacuum FS801 — Changing & Cleaning the Pre- diagram (page 4)
Fig. 8 · Changing & Cleaning the Pre-
  • Rinse the pre-motor filter in lukewarm water and air dry the filter completely

machine to rinse the filter. Do not use

Never operate the vacuum without the

  • When the filter is dry, replace into the unit and replace the HEPA filter and

The post motor filter is a washable filter

  • Remove the filter cover from the front of the unit and remove the filter.

The pre-motor filter is a washable filter

but should be replaced every three (3)

but should be replaced every three (3)

  • Remove the dust cup container, the non-woven pre-filter and the HEPA

filter to remove the pre-motor filter.

for 24 hours. Do not use a washing

fresh tepid water. A mild detergent

  • A severely soiled or clogged filter should be thoroughly washed with
Fantom Vacuum FS801 — Changing & Cleaning the Pre- diagram (page 4)
Fig. 9 · Changing & Cleaning the Pre-

Changing & Cleaning the Pre-

a hair dryer to dry it. Air dry only.

pre-motor filter in place.

can be used if required.

Fig. A Wash once a month or when suction HEPA filter appears a hair dryer to dry it. Air dry only. apCleaned” reduced Never operate the vacuum without the pre-motor filter in place. ously until Warning: Allow 24 • When the filter is dry, replace into the ore dust hours for drying before unit and replace the HEPA filter and be removed, replacing in unit. dust cup container. rinsed • A severely soiled or clogged filter r the faucet and allowed to air dry should be thoroughly washed with 4 hours before refitting into the fresh tepid water. A mild detergent um. (Fig. A) This should be can be used if required. e once a month or when ion appears to be reduced . CAUTION: The suction hole must be open, free of any obstructions at all times. Otherwise, the motor will overheat and could become Pre-Motor Filter damaged. Warning: Always empty the dust cup container and clean the HEPA filter, Non-Woven Pre-Filter and Debris Screen before each use and during prolonged usage. Changing & Cleaning the Post Motor Filter ver over fill the dust cup container - The post motor filter is a washable filter ove dirt and clean the HEPA filter, but should be replaced every three (3) -woven pre-filter and debris screen months. en dirt in dust cup is at or below the • Remove the filter cover from the front AX" level during prolonged usage or of the unit and remove the filter. motor damage. • Rinse the post ou wash the Hepa filter or the nonmotor filter in ven pre-filter, make sure that it isappears reduced Warning: Allow 24 hours for drying before replacing in unit.a hair dryer to dry it. Air dry only. Never operate the vacuum without the pre-motor filter in place. ore

dust cup container.

  • Rinse the post motor filter in

OPERATING INSTRUCTIONS PRECAUTIONARY MEASURES

Motor Filter

months.

months.

Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 10 · Motor Filter
Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 11 · Motor Filter

If you wash the Hepa filter or the non-

Never over fill the dust cup container -

remove dirt and clean the HEPA filter,

non-woven pre-filter and debris screen

when dirt in dust cup is at or below the

"MAX" level during prolonged usage or

woven pre-filter, make sure that it is

hours for drying before

under the faucet and allowed to air dry

discolor over time -This is NORMAL

and will NOT affect the performance

PLEASE NOTEThe white pleated

filter material in the HEPA Filter will

for 24 hours before refitting into the

replacing in unit.

vacuum. (Fig. A) This should be

suction appears to be reduced .

Fig. A

done once a month or when

of the filter. If the HEPA Filter

risk motor damage.

4. When pulling out the power plug from the wall outlet, pull the plug not

the vacuum cleaner and remove the blocking substance before you

cigarettes, matches or hot ashes.

6. Do not use without HEPA filter in place.
Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 12 · Motor Filter
5. Do not pick up anything that is burning or smoking such as

the power cord.

3. Before you start vacuuming, make sure to remove large or sharp objects
Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 13 · Motor Filter
1. Do not operate the vacuum cleaner too close to heaters, radiators or
2. Before inserting the power plug into the wall outlet, make sure that your

start the unit again.

Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 14 · Motor Filter
Fantom Vacuum FS801 — Motor Filter diagram (page 4)
Fig. 15 · Motor Filter

that might damage the dust cup

cigarette butts.

hands are dry.

debris screen.

Show 20 more labels / short text on this page
month or · appears · once a · suction · reduced · Wash · when · be “TapCleaned” · can be removed, · does not return · we suggest that · the HEPA filter · vigorously until · "TapCleaned” · after each use · to 100%, then · no more dust · is properly · and suction · then rinsed
Page 5 of the Fantom Vacuum FS801 user manual — Debris Screen
Page 5 · click to enlarge
Page 5
Fantom Vacuum FS801 — ATTACHING THE FLOOR BRUSH diagram (page 5)
Fig. 16

ATTACHING THE FLOOR BRUSH

  • Insert the floor brush into its location, in the direction of the arrow.

release button and pull the floor brush

ATTACHING THE HOSE TO THE

  • Insert the hose into the hose connector (see arrow in illustration).
  • To remove the floor brush from the main unit, press on the floor brush
  • Hold the end of the hose (see illustration below).
Fantom Vacuum FS801 — ATTACHING THE HOSE TO THE diagram (page 5)
Fig. 17

TO THE MAIN UNIT

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS cont.

MAIN UNIT

out.

  • Insert the telescopic tube into the hole next to the dust cup handle. Make
  • To remove the telescopic tube, press the telescopic tube release button and

Push the plastic button and pull out the

assembling or removing accessories.

EXTENDING THE TELESCOPIC

INSERTING THE TELESCOPIC

sure that the slot in the handle fits

Fantom Vacuum FS801 — EXTENDING THE TELESCOPIC diagram (page 5)
Fig. 18

smaller tube. See illustration below.

Fantom Vacuum FS801 — EXTENDING THE TELESCOPIC diagram (page 5)
Fig. 19

correctly into the opening. (See

TUBE INTO THE MAIN UNIT

plug from the wall outlet before

pull the tube up.

illustration.)

TUBE

3. The HEPA filter is located underneath the dust cup container. (See
8. To Separate the Debris Screen from the dust cup, hold the dust cup in one

before inserting back into the vacuum.

Fantom Vacuum FS801 — TUBE diagram (page 5)
Fig. 20

illustration.) Remove the non-woven

hold the edges and pull it out slowly.

counter clockwise and pull apart. To

pre-filter. Remove the HEPA filter,

5. Rinse the non-woven pre-filter and let d\air dry completely for 24 hours.

HEPA

hand and turn the dust cup cover

always allow 24 hours to air dry

6. Insert the non-woven pre-filter. 7. Reinstall the HEPA filter in the vacuum.

clean the Debris Screen, we

more dust is observed

the HEPA Filter dirty

side down on a hard,

between the pleats of

accumulates on it, but

side of the dust cup

4. Hold the HEPA filter by the edges and
2. To empty the dust cup container,

that is on the back

flat surface until no

press on the trap

Fantom Vacuum FS801 — HEPA diagram (page 5)
Fig. 21

you rinse it under

container.

the filter.

the air you breathe. In fact it stops 99.97%

Emptying the Dust Cup Container

opening the Dust Cup (container).

then vigorously “TapClean” HEPA

many fine dust particles that are difficult to

reduce your suction power - if not cleaned

and Cleaning / Changing the Non-

unit from electrical outlet before

“TapClean” HEPA Filter will stop most of

the tiniest dust particles from re-entering

many times smaller than a human hair!!!

performance, the HEPA Filter will quickly

button (1) that is located on the dust

press on the dust cup release button

housing. See illustration below. Then

Woven Pre-Filter, HEPA Filter &

Cover with the Debris Screen,

Filter and clean Debris Screen

of all particles as small as 0.3 microns -

accumulate, inside the white filter folds,

see but which will eventually block or

1. To remove the dust cup container, first press on the dust cup release

(2) that is on the side of the upper

Fantom Vacuum FS801 — Woven Pre-Filter, HEPA Filter & diagram (page 5)
Fig. 22 · Woven Pre-Filter, HEPA Filter &

Assembly and the Dust Cup

cup handle and at the same time

Because of this incredible filtration

pull the dust cup container out.

without the HEPA filter in place.

Always remove the Filter

until no more dust can be

Debris Screen

removed.

properly.

Show 18 more labels / short text on this page
Non-Woven · Pre-Filter · Filter · vigorously “TapClean” · door release button · lukewarm running · recommend that · water to remove · falling out from · the dirt that · Release · Button 1 · Dust · Cup · Release · Button 2 · Dust · Cup
Page 6 of the Fantom Vacuum FS801 user manual — = ON
Page 6 · click to enlarge
Page 6

empty the dust cup frequently and shake

same time. Ensure that the rotating brush

1. Remove the turbo brush from the hose or extension tube.
2. Slide locking latch forward then tilt the top housing of the brush upwards. The
3. There may be some dust, lint, hair, etc on the turbine wheel. Remove as much
4. You may also use the unit’s hose with crevice tool attached and use the
6. Once clean, close the top cover of the turbo brush and slide the locking latch

woven pre-filter and debris screen at the

is kept free of hair and string which may

turbo brush will require cleaning. To do

5. Ensure that the turbine wheel moves freely by rotating it with your finger. If

Cleaning Air Driven Turbo Brush

Fantom Vacuum FS801 — Cleaning Air Driven Turbo Brush diagram (page 6)
Fig. 23 · Cleaning Air Driven Turbo Brush

From time to time, the turbine of your

top housing is hinged and will tilt up

toward the rear of the brush to lock.

out the HEPA filter and clean the non-

maximum air suction is maintained,

vacuum to remove any additional

the turbine does not rotate, call

accumulate and decrease brush

Customer Service for help.

approximately 45° only.

debris from the turbine.

OPERATING INSTRUCTIONS cont. OPERATING INSTRUCTIONS cont.

of this as possible.

performance.

this:

rotating at high speed. Strong air suction

is needed to accomplish this. In order to

1. Empty the dust cup frequently. 2. Always shake out the HEPA filter and clean the non-woven pre-filter and

debris screen when emptying the dust

3. Ensure that the rotating brush is kept free of hair and string which may
2. Push the air driven turbo brush onto the end of the flexible hose as far as
4. Keep Air Driven Turbo Brush turbine free of dirt and foreign matter. (See

illustration for cleaning instructions.)

1. Remove the flexible hose from the hose connector. (See below)

Using The Unit With Air Driven

The efficiency of your air driven turbo

maintained, please read the following

= OFF Attaching the Air Driven Turbo

brush depends on the bristle brush

ensure that maximum air suction is

To use the air driven turbo brush to

accumulate and decrease brush

Air Driven Turbo Brush

Brush to the Flexible Hose

Fantom Vacuum FS801 — Brush to the Flexible Hose diagram (page 6)
Fig. 24 · Brush to the Flexible Hose

clean upholstery:

cup container.

performance.

Turbo Brush

it will go.

instructions:

  • Press the floor brush release button to remove the floor brush. (See page 4)
  • Press the telescopic tube release button to remove the telescopic tube.
  • Attach the shoulder strap to the shoulder strap attachment point. (See
  • Attach the crevice tool or the dusting brush to the end of the hose.
Fantom Vacuum FS801 — Turbo Brush diagram (page 6)
Fig. 25 · Turbo Brush

When using the unit with the shoulder

with the shoulder strap. If during use,

the vacuum gets too warm, allow it to

USING THE UNIT AS A HAND

After extended use, the body of the

strap, the unit will touch the body of

the user. Therefore, make sure that

the unit body is cool before you use

Monitor lights up, it means that the

vacuum cleaner may become hot.

Intelli-Sense TM Filter Monitor

dust cup is full or the HEPA filter,

screen needs cleaning. You must

woven pre-filter and debris screen

For radiators, crevices, corners,

empty the dust from the dust cup

When the Intelli-SenseTM Filter

and clean the HEPA filter, non-

cool before continuing to use.

non-woven pre-filter or debris

used for the furniture,

illustration below.)

WARNING

The dusting brush is

between cushions.

and shelves.

VACUUM

right away.

Fantom Vacuum FS801 — VACUUM diagram (page 6)
Fig. 26
Fantom Vacuum FS801 — VACUUM diagram (page 6)
Fig. 27

USING THE UNIT AS AN UPRIGHT

  • The On/Off switch has two different positions.

WINDING & UNWINDING THE

  • Push on the "O" side to turn the vacuum OFF.
  • Push on the "I" side to turn the vacuum ON.

equipped with a convenient

cord storage feature. The

power cord winds around

the back of the unit. The

  • Unwind the power cord and plug into the

120V outlet. • Push down on the locking button to adjust

This vacuum cleaner is

bottom one has a quick

remove the power cord.

carpets, lower the angle

the two cord holders at

Turn the cord hook to

See illustration at right.

cord release feature.

the left or the right to

ON/OFF SWITCH

deep pile carpets or

the height of the

telescopic handle.

POWER CORD

maneuverability.

= ON

Show 17 more labels / short text on this page
Upwards · Tilt · Locking Latch · Turbine · books, lamp shades · baseboards and · Dusting Brush · venetian blinds, · (See page 4) · Crevice Tool · Lower · hard to vacuum · of the telescopic · illustration at · handle (see · right) for · easier
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
VACUUM WILL NOT OPERATE1. Power cord not firmly plugged into outlet. 2. No power in wall outlet. 3. Needs servicing. 4. Thermostat has tripped.1. Plug unit in firmly. 2. Check fuse or breaker. Replace fuse/reset breaker. 3. Call 1-800-275-9251. 4. Turn the unit off and unplug from outlet. Allow unit to cool down, then restart. p.3
VACUUM WILL NOT PICK-UP OR SUCTION POWER IS WEAK1. Dust cup is full. 2. Unit clogged. 3. HEPA Filter needs cleaning or replacing. 4. Debris screen needs cleaning. 5. Filters need cleaning.1. Empty and clean dust cup. 2. Turn unit off and unplug from wall outlet. Remove Dust Cup Filter and check for object(s) in air duct and remove. 3. Clean or replace HEPA Filter. 4. Clean debris screen. 5. Clean filters. p.3
TURBO BRUSH DOES NOT ROTATE OR ROTATES SLOWLY1. Dust cup is full. 2. Rotating brush or elbow is obstructed. 3. Belt is broken. 4. Hose obstructed. 5. Debris screen is clogged. 6. Filters need cleaning.1. Empty dust cup. 2. Clear obstructions. 3. Call 1-800-275-9251. 4. Clear obstruction. 5. Clean debris screen. 6. Clean filters. p.3
DUST ESCAPING FROM VACUUM1. Dust cup is full. 2. Dust Cup is not installed correctly.1. Empty and clean dust cup. 2. Review Dust Cup instructions. p.3
VACUUM, HOSE OR BRUSHES WILL NOT PICK-UP1. Hose clogged. 2. Dust cup is full.1. Remove hose and/or brushes. Remove obstruction from hose and /or brush. 2. Empty and clean dust cup. p.3

Ask about the Fantom Vacuum FS801

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fantom Vacuum FS801

Be the first to ask — other owners or our team will answer.

Original document

Fantom Vacuum FS801 manual PDF

6 pages·580 KB·Vacuum Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…