IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following.

READ ALL INSTRUCTIONS

BEFORE USING THIS VACUUM CLEANER WARNING - To reduce the risk of fire, electric shock or injury:

1. Do not leave the vacuum cleaner when plugged in. Unplug it from the outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not allow vacuum cleaner to be used as a toy. Close attention is necessary when used by or near children or infirmed persons.
4. Use only as described in this manual. Use only the manufacturer's recommended attachments.
5. Do not use with a damaged cord or plug. If the vacuum cleaner is not working as it should, or if it has been dropped, damaged, left outdoors or dropped into water, return to FANTOM at 94 Main Mill Street, Door 16, Plattsburgh , NY 129 01 .
6. Do not pull or carry by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
7. Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
8. Do not handle the plug or the vacuum cleaner with wet hands.
9. Do not put any objects into the openings. Do not use with any opening blocked: keep free of dust, lint, hair and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers and all the parts of your body away from openings and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
12. Do not use without dust compartment and filters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline, or use in areas where they may be present.

1 Rev. 09/03B

Page 3 of the Fantom Vacuum FM741B user manual — Note to user concerning attachment plug:
Page 3 · click to enlarge
Page 3
16. Do not touch the agitator while it is spinning.
17. Do not place any heavy items on top of the vacuum cleaner.
18. Do not step on the hose or pull it too strongly.
19. Do not pick up items such as pieces of waste paper or cloth which look as though they may cause the hose to become blocked.
20. Do not clean or store the vacuum cleaner in places where there are high temperatures.
21. Store the vacuum cleaner away from excessive humidity.
22. When carrying the vacuum cleaner, hold it by the carrying handle.
23. Before servicing the vacuum cleaner, allow all internal metal parts to cool first.
24. Always place foot on handle release when adjusting the handle position

of the vacuum cleaner.

25. If the supply cord of this appliance is damaged, it must only be replaced by FANTOM, because special purpose tools are required.

SAVE THESE INSTRUCTIONS

This vacuum cleaner is intended for household use only.

Note to user concerning attachment plug:

To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

Page 4 of the Fantom Vacuum FM741B user manual — SAVE THESE INSTRUCTIONS
Page 4 · click to enlarge
Page 4
Fantom Vacuum FM741B — SAVE THESE INSTRUCTIONS diagram (page 4)
Fig. 1
Fantom Vacuum FM741B — SAVE THESE INSTRUCTIONS diagram (page 4)
Fig. 2

Plug shown in figure may differ from actual plug attached to unit for your area.

Set the ON/OFF switch to " ON " to light the headlight.

Page 5 of the Fantom Vacuum FM741B user manual — Attaching the suction hose A & attachments
Page 5 · click to enlarge
Page 5

PREPARATIONS BEFORE USE

Attaching the handle

Fantom Vacuum FM741B — Attaching the handle diagram (page 5)
Fig. 3 · Attaching the handle

1 2 Set the vacuum cleaner to the upright position.

Attaching the suction hose A & attachments

Fantom Vacuum FM741B — Attaching the suction hose A & attachments diagram (page 5)
Fig. 4 · Attaching the suction hose A & attachments
Page 6 of the Fantom Vacuum FM741B user manual — INSERTING THE POWER CORD PLUG
Page 6 · click to enlarge
Page 6

PREPARATIONS BEFORE USE

WINDING THE POWER CORD

Fantom Vacuum FM741B — PREPARATIONS BEFORE USE diagram (page 6)
Fig. 5

Wind the power cord around the cord storage hooks.

Hook the power cord over the clip which is located on the upper cord storage hook as shown.

Secure the power cord plug on the power cord.

RELEASING THE POWER CORD

Fantom Vacuum FM741B — RELEASING THE POWER CORD diagram (page 6)
Fig. 6

Return the hook to the upright position before attempting to rewind the power cord.

INSERTING THE POWER CORD PLUG

Fantom Vacuum FM741B — INSERTING THE POWER CORD PLUG diagram (page 6)
Fig. 7

WARNING: To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plug in any way.

Page 7 of the Fantom Vacuum FM741B user manual — ADJUSTING THE HANDLE
Page 7 · click to enlarge
Page 7

USING THE VACUUM CLEANER

ON/OFF SWITCH

Fantom Vacuum FM741B — USING THE VACUUM CLEANER diagram (page 7)
Fig. 8

Start or stop vacuum cleaner by pushing on the switch.

ADJUSTING THE HANDLE

Fantom Vacuum FM741B — ADJUSTING THE HANDLE diagram (page 7)
Fig. 9

The handle of this vacuum cleaner can be set to one of three positions -Upright, Normal, Parallel. Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright position.

position for storage or when using the attachments. Push the handle forward until it locks.

Page 8 of the Fantom Vacuum FM741B user manual — EDGE CLEANING
Page 8 · click to enlarge
Page 8

USING THE VACUUM CLEANER

RUG/FLOOR (TOOLS)SELECTOR

Fantom Vacuum FM741B — USING THE VACUUM CLEANER diagram (page 8)
Fig. 10

The RUG/FLOOR(TOOLS)selector should only be adjusted while the vacuum cleaner is turned on and in the upright position.

When cleaning a rug or carpet,first turn the ON/OFF switch to the ON position,and then set the RUG/ FLOOR(TOOLS)selector to the RUG position.

When cleaning a bare floor or when using one of the attachments,set the RUG/FLOOR (TOOLS)selector to the FLOOR position.

EDGE CLEANING

This vacuum cleaner is equipped with an "edge cleaning" function for cleaning carpet edges near baseboards and stationary furniture.

Page 9 of the Fantom Vacuum FM741B user manual — Upholstery tool & Dusting brush
Page 9 · click to enlarge
Page 9

USING THE ATTACHMENTS

Remove the attachments from the vacuum cleaner.

Press the release button C to disconnect the handle from the vacuum cleaner.

When removing the attachments, pull

them in the directions shown in the

illustration.Pulling them in the wrong

direction or pulling them forcefully may

cause damage to the attachment clamp.

Attach the attachments on the handle or the suction hose B.

Attach the attachments as shown below.

please make sure the handle is reattached on the body.

Hook the hose holder onto the holder mount.

Before using the attachments, please make sure the hose is hooked on the holder mount.

Upholstery tool & Dusting brush

Holder Mount Hose Holder

To detach the dusting brush from the upholstery tool: Press the tabs on the brush downward to remove it.

To reattach the dusting brush to the upholstery tool: Insert the front of the upholstery tool under the hook on the front of the dusting brush. Press down on the back of the upholstery tool to snap it into place under the dusting brush tabs.

When you have finished using the attachments,replace them in their original positions as shown on page 4.

Show 12 more labels / short text on this page
Wand · Crevice Tool · Release Button C · Attachment Clamp · Upholstery Tool · Dusting Brush · Wand Crevice Tool · Handle · Suction Hose A · Suction Hose B · Groove · Tabs
Page 10 of the Fantom Vacuum FM741B user manual — EMPTYING THE DUST COMPARTMENT
Page 10 · click to enlarge
Page 10

EMPTYING THE DUST COMPARTMENT

Fantom Vacuum FM741B — EMPTYING THE DUST COMPARTMENT diagram (page 10)
Fig. 11

Empty the dust compartment when contents reach the MAX mark.

Press the release button A meanwhile press the release button B to remove the dust compartment.

Turn the duster handle several times in the direction shown to empty the dust compartment.

Close the trapdoor and insert the projection on the dust compartment into the groove on the main body.

Push the dust compartment into the main body as shown to reattach.

Page 11 of the Fantom Vacuum FM741B user manual — Reattaching the filters
Page 11 · click to enlarge
Page 11

CLEANING THE FILTERS

Remove the dust compartment.(refer to page 9)

2 Set the dust compartment to the parallel position.Open the trapdoor,then push the release button E and pull out the main filter.

The main filter and prefilter will be removed at the same time.

Fantom Vacuum FM741B — CLEANING THE FILTERS diagram (page 11)
Fig. 12

3 Clean the main filter and prefilter with a soft-bristled brush (not included) and rinse with cold water. Allow both items to dry completely for 24 hours.

Fantom Vacuum FM741B — CLEANING THE FILTERS diagram (page 11)
Fig. 13

Do not use a hard-bristled brush to clean filters. This may result in damage to the filters. Do not attempt to dry with a hair dryer or by placing in a clothes dryer.Hot air may cause the filters to warp.

To maintain optimum suction power, the dust filter fins should be kept clean of dirt. Cleaning Utensil

Clean the filter fins free of dirt with the forked end of cleaning utensil as shown.

Reattaching the filters

Insert the main filter into the prefilter as shown.

2 Hold onto the main filter and insert into the dust compartment.

Align the ribs of the main filter to match the shape of the opening in the dust compartment and press firmly to insert.

3 Close the trapdoor.

Show 6 more labels / short text on this page
Release Button E · Cleaning Utensil · Prefilter · Dust Compartment · Hole · Ribs Main Filter
Page 12 of the Fantom Vacuum FM741B user manual — Cleaning the agitator assembly
Page 12 · click to enlarge
Page 12
Fantom Vacuum FM741B — Cleaning blockages diagram (page 12)
Fig. 14 · Cleaning blockages

the power cord from the wall outlet before clearing any blockages in the suction hose and cleaning the agitator assembly.

Cleaning blockages

Suction Hose A Cleaning blockages in the suction hose A, B

Fantom Vacuum FM741B — Suction Hose A Cleaning blockages in the suction hose A, B diagram (page 12)
Fig. 15 · Suction Hose A Cleaning blockages in the suction hos…

Set the vacuum cleaner to the upright position.

Remove the hose cuff from the suction inlet and then remove any blockages from the hose.

Reattach the hose cuff to the suction inlet,and

then operate the vacuum cleaner to check that

the blockage has been properly cleared.If the hose is still blocked,the suction force will be weak.

Fantom Vacuum FM741B — Suction Hose A Cleaning blockages in the suction hose A, B diagram (page 12)
Fig. 16 · Suction Hose A Cleaning blockages in the suction hos…

Cleaning blockages in the nozzle head

Remove the bottom plate(refer to page 14)

Remove any blockages from the nozzle head.

Reattach the bottom plate to the nozzle head, and then operate the vacuum cleaner to check that the blockage has been properly cleared. If the nozzle head is still blocked, the suction force will be weak.

When the suction hose A, B or Nozzle head is blocked, the bypass valve will be opened automatically to protect the motor, resulting in the suction force being reduced. The bypass valve will be at its original position automatically after the blockage is removed.

Fantom Vacuum FM741B — Cleaning blockages in the nozzle head diagram (page 12)
Fig. 17 · Cleaning blockages in the nozzle head

Cleaning the agitator assembly

Fantom Vacuum FM741B — Cleaning the agitator assembly diagram (page 12)
Fig. 18 · Cleaning the agitator assembly

When threads get caught in the agitator assembly, clean the assembly.

Remove threads caught in the assembly by cutting them with scissors.

Show 4 more labels / short text on this page
Hose Cuff · Suction Inlet · Nozzle Head · Nozzle Pipe
Page 13 of the Fantom Vacuum FM741B user manual — REPLACING THE HEADLIGHT LAMP
Page 13 · click to enlarge
Page 13

power cord from the wall outlet before replacing any of the parts below.

REPLACING THE HEADLIGHT LAMP

Fantom Vacuum FM741B — REPLACING THE HEADLIGHT LAMP diagram (page 13)
Fig. 19

1 Set the vacuum cleaner to the parallel position.

Push a new lamp gently into the socket and

Page 14 of the Fantom Vacuum FM741B user manual — REPLACING THE FLAT BELT
Page 14 · click to enlarge
Page 14

power cord from the wall outlet before replacing any of the parts below.

REPLACING THE FLAT BELT

Fantom Vacuum FM741B — REPLACING THE FLAT BELT diagram (page 14)
Fig. 20

Lift out the agitator assembly,and then remove the flat belt from the motor shaft and the agitator pulley.

Place a new flat belt onto the motor shaft and pulley.

Place the agitator assembly into the grooves in the nozzle head, making sure that the new flat belt slides securely into the guide.

Page 15 of the Fantom Vacuum FM741B user manual — REATTACHING THE BOTTOM PLATE
Page 15 · click to enlarge
Page 15

REMOVING THE BOTTOM PLATE

Fantom Vacuum FM741B — REMOVING THE BOTTOM PLATE diagram (page 15)
Fig. 21

Set the vacuum cleaner to the parallel position and turn it over.

Slide the latch in the direction of the arrow.

Remove the bottom plate by pulling the tabs as illustrated.

REATTACHING THE BOTTOM PLATE

Fantom Vacuum FM741B — REATTACHING THE BOTTOM PLATE diagram (page 15)
Fig. 22

Insert the projection on the bottom plate into the groove on the nozzle housing

Turn the vacuum over and place in the upright position.

Page 16 of the Fantom Vacuum FM741B user manual — CLEANING THE SUB-FILTER
Page 16 · click to enlarge
Page 16

REPLACING THE FILTER

Under normal usage, the HEPA Filter will require replacement once every three (3) months, however, vacuuming large amounts of extremely fine dust, powder or similar material over a long period of time may decrease airflow performance through the filter. If this occurs, it may become necessary to replace the HEPA Filter more often. Only use genuine FANTOM replacement filters.

and pull the filter cover away from the vacuum cleaner.

1 Press in the locking tabs at points

Remove the HEPAfilter.

Do not attempt to wash the HEPA filter.

Always replace the old filter with a new one.

Insert a new HEPA filter with the seal

to the inside of the vacuum cleaner.

Reattach the filter cover.

Be sure that seal on the HEPAfilter is inserted

towards the inside of the vacuum cleaner.

The filter cover should be correctly oriented

when it is reattached. Do not reattach it upside down.

CLEANING THE SUB-FILTER

Clean the sub-filter when it becomes dirty. Remove the dust compartment (refer to page 8). Remove the air inlet cover.

Remove the sub-filter from the vacuum cleaner.

1 Sub-Filter Air Inlet Cover

Gently clean the sub-filter with water.

Make sure that it is completely dry and then re-install it into the vacuum cleaner. Replace the air inlet cover and the dust compartment.

Caution: Do not wash the sub-filter in a washing machine, and do not use any other equipment such as a hair dryer to dry it. Always allow 24 hours for drying. Do not operate the vacuum without the sub-filter. Be sure the sub-filter is dry and properly installed. Failure to do so could result in electrical shock, personal injury, or motor failure.

Note: We recommend replacing the sub-filter every three (3) to six (6) months, depending on usage.

Filter Cover · HEPA Filter · Seal

Page 17 of the Fantom Vacuum FM741B user manual — 9BF-D-P111-00721 0304-
Page 17 · click to enlarge
Page 17

TROUBLESHOOTING

If there is a problem with the vacuum cleaner, carry out the following checks to find the cause. If the problem still persists after the checks have been made, do not use the vacuum cleaner to prevent the possibility of an accident occurring. Turn the ON/OFF switch to the "OFF" position, disconnect the power cord from the wall outlet, and contact FANTOM Customer Service at 1-800-275-9251. Or visit our website at www.fantom.com

Problem Cause R emedy

The motor does not operate when the ON/OFF switch is set to the "ON" position.

The power cord plug is not securely inserted into the wall outlet.

Insert the power cord plug securely into the wall outlet.(refer to page 5 )

The dust compartment is full.

Empty the dust compartment. (refer to page 9) Remove the blockage. (refer to page 11)

Suction force is weak.

The suction hose is blocked.

The nozzle head is blocked.

Remove the blockage. (refer to page 11)

The filters are dirty.

Clean the filters. (refer to page 10)

(refer to page 15)

The nozzle air inlet pipe is blocked.

Remove the blockage. (refer to page 11)

The bypass vavle is opened.

Remove the blockage. (refer to page 11)

The agitator does not operate.

The flat belt is worn or broken.

Replace the flat belt. (refer to page 13)

TO ORDER REPLACEMENT FILTERS CALL 1-800-275-9251

9BF-D-P111-00721 0304-

E

Page 18 of the Fantom Vacuum FM741B user manual — OWNERSHIP REGISTRATION CARD
Page 18 · click to enlarge
Page 18

ONE (1) YEAR LIMITED WARRANTY

FANTOM warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of the original purchase, when utilized for normal household use, subject to the following conditions, exclusions and exceptions.

If your appliance fails to operate properly while in use under norma l household conditions within the warranty period, return the complete appliance and accessories, freight prepaid to

In USFANTOM ,, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901

If the appliance is found by FANTOM to be defective in material or workmanship, FANTOM will repair or replace it free of charge. Proof of purchase date and $19.95 to cover the cost of return shipping and handling must be included. *

Non-durable parts including, without limitation, dust cup filters, filters, belts, brushes and electrical parts which normally require replacement are specifically excluded from warranty.

The liability of FANTOM warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes. This limited warranty does not cover damage caused by misuse, abuse, negligent handling or damage due to faulty packaging or mishandling in transit. This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or any of its parts, which have been performed by a repair person not authorized by FANTOM.

is limited solely to the cost of the repair or replacement of the unit at our option. This

This warranty is extended to the original purchaser of the unit and excludes all other legal and/or conventional warranties. The responsibility of FANTOM if any, is limited to the specific obligations expressly assumed by it under the terms of the limited warranty. In no event is FANTOM liable for incidental or consequential damages of any nature whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with your name, c omplete address and phone number with a note giving purchase information, model number and what you believe is the problem with item. We recommend you insure the package (as damage in shipping is not covered by your warranty). Mark the outside of your package "ATTENTION ,, CUSTOMER SERVICE .

OWNERSHIP REGISTRATION CARD

Please fill out and mail the product registration card within ten (10) days of purchase. The registration will enable us to contact you in the unlikely event of a product safety notification. By returning this card you acknowledge to have read and understood the instructions for use, and warnings set forth in the accompanying instructions.

RETURN TO FANTOM, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901

Date purchased Name of store

, Owner s name

Address City State Zip Code

Model FM741B · Appliance model · Printed in China

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The motor does not operate when the ON/OFF switch is set to the "ON" position.The power cord plug is not securely inserted into the wall outlet. p.17
Suction force is weak.The dust compartment is full. The suction hose is blocked. The nozzle head is blocked. The filters are dirty. The nozzle air inlet pipe is blocked. The bypass vavle is opened. p.17
The agitator does not operate.The flat belt is worn or broken. p.17

Ask about the Fantom Vacuum FM741B

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fantom Vacuum FM741B

Be the first to ask — other owners or our team will answer.

Original document

Fantom Vacuum FM741B manual PDF

18 pages·4.9 MB·Vacuum Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…