EN
Fantom Vacuum logo
Official user manual

Fantom Vacuum FM718

8 pages·1.1 MB·Vacuum Cleaner·PDF·ENDEFRITNLJA
Fantom Vacuum FM718
Table of Contents 41 sections CYCLONIC BAGLESS UPRIGHT · FANTOM · OWNER’S MANUAL · Model FM718 · … ShowHide
Page 1 of the Fantom Vacuum FM718 user manual — FANTOM
Page 1 · click to enlarge
Page 1
Fantom Vacuum FM718 — CYCLONIC BAGLESS UPRIGHT diagram (page 1)
Fig. 1

CYCLONIC BAGLESS UPRIGHT

Fantom Vacuum FM718 — CYCLONIC BAGLESS UPRIGHT diagram (page 1)
Fig. 2

94 Main Mill Street, Door 16 Plattsburgh, NY 12901

Tel.: 1 (800) 275-9251

www.fantom.com

FANTOM

OWNER’S MANUAL

Model FM718

120V., 60Hz., 12 Amps

Page 2 of the Fantom Vacuum FM718 user manual — is not covered by your warranty). Mark the outside of your package
Page 2 · click to enlarge
Page 2

The liability of FANTOM is limited solely to the cost of the repair or replacement

This warranty gives you specific legal rights, and you may also have other rights

purchase information, model number and what you believe is the problem

with item. We recommend you insure the package (as damage in shipping

workmanship for a period of one (1) year from the date of the original purchase.

of the unit at our option. This warranty does not cover normal wear of parts and

does not apply to any unit that has been tampered with or used for commercial

abuse, negligent handling or damage due to faulty packaging or mishandling in

transit. This warranty does not cover damage or defects caused by or resulting

the exclusion or limitation of incidental or consequential damages, so the above

bulbs and electrical parts which normally require replacement are specifically

from damages from shipping or repairs, service or alterations to the product or

any of its parts, which have been performed by a repair person not authorized

This warranty is extended to the original purchaser of the unit and excludes all

consequential damages of any nature whatsoever. Some states do not permit

*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing

with your name, complete address and phone number with a note giving

improve our products, therefore the specifications contained herein are

FANTOM will repair or replace it free of charge. Proof of purchase date and

other legal and/or conventional warranties. The responsibility of FANTOM if

terms of the limited warranty. In no event is FANTOM liable for incidental or

This warranty applies only to normal domestic household use. Should your

$16.95 to cover the cost of return shipping and handling must be included. *

Non-durable parts including, without limitation, drive belts, rotating brushes,

purposes. This limited warranty does not cover damage caused by misuse,

any, is limited to the specific obligations expressly assumed by it under the

Should the appliance is found to be defective in material or workmanship,

is not covered by your warranty). Mark the outside of your package

“ATTENTION CUSTOMER SERVICE”. We are constantly striving to

ONE (1) YEAR LIMITED WARRANTY

FANTOM warrants this product to be free from defects in material and

appliance fail to operate properly while in use under normal household

conditions within the one (1) year warranty period, return the complete

FANTOM 94 Main Mill Street, Door 16, Plattsburgh, NY 12901

Fantom Vacuum FM718 — is not covered by your warranty). Mark the outside of your package diagram (page 2)
Fig. 3 · is not covered by your warranty). Mark the outside o…

appliance and accessories, freight prepaid to:

Printed in China 12

subject to change without notice.

which vary from state to state.

excluded from warranty.

may not apply to you.

by FANTOM.

Model FM718

Page 3 of the Fantom Vacuum FM718 user manual — For Household Use Only
Page 3 · click to enlarge
Page 3

IMPORTANT SAFETY INSTRUCTIONS

17. Do NOT pick up toxic material (chlorine
22. Do NOT put any objects into openings.

Do NOT use with any opening blocked.

provided by FANTOM. Failure to do so

14. Turn off all controls before plugging or unplugging vacuum cleaner into

gasoline, kerosene, etc.) or use in the

presence of explosive liquids or vapor.

filled with vapors given off by oil based

anything else that may reduce air flow.

23. Store your appliance indoors in a cool,

the vacuum cleaner head moving at all

SAVE THESE INSTRUCTIONS

Rev. 01/04A 1

When using your Bagless Upright Vacuum, basic safety precautions should

bleach, ammonia, drain cleaner, etc.).

substances, flammable dust, or other

26. Keep end of hose, wands and other
27. To avoid damaging the carpet, keep
13. Do NOT use without filters in place.
15. Use extra care when vacuuming on

combustible materials (lighter fluid,

18. Do NOT use in an enclosed space

paints, paint thinner, moth proofing

20. Do NOT use for any purpose other

than described in this user’s guide.

21. The use of an extension cord is not
25. Do NOT immerse the vacuum into

openings away from your face and

polarized plug (one blade is wider than the other). This plug will fit in a

polarized outlet only one way. If the plug does not fit fully in the outlet,

reverse the plug. If it still does not fit, contact a qualified electrician to install

Use ONLY filters and accessories

19. Use only on dry, indoor surfaces.

Keep free of dust, lint, hair and

16. Do NOT pick up flammable or
24. Keep your work area well lit.

explosive or toxic vapors.

For Household Use Only

will void the warranty.

water or other liquids.

electrical outlet.

recommended.

the proper outlet. Do NOT modify the plug in any way.

dry area.

times.

stairs.

body.

always be observed, including the following:

Do NOT use vacuum cleaner if it has been

6. Do NOT pull or carry by cord. Do NOT use
10. Keep hair, loose clothing, fingers, feet and all parts of body away from openings,

unattended when it is plugged in. Unplug

4. Use only as described in this manual. Use

corners. Do NOT run appliance over cord.

11. Do NOT pick up hot coals, cigarette butts, matches or any hot, smoking, or burning
2. To reduce the risk of electric shock – do

Close attention is necessary when used

5. Do NOT use with damaged cord or plug.

dropped into water. Return appliance to

cord as a handle, close a door on cord,

8. Do NOT handle plug or vacuum cleaner
9. Do NOT use the vacuum cleaner to pick

up large objects or objects that are likely

rotating agitator and other moving parts.

Do NOT operate cleaner in bare feet or

from outlet when not in use and before

NOT use outdoors or on wet surfaces.

3. Do NOT allow children to use as a toy.

Keep cord away from heated surfaces.

7. Do NOT unplug by pulling on cord. To
12. Do NOT pick up hard or sharp objects such as glass, nails, screws, coins, etc.

dropped, damaged, left outdoors, or

unplug, grasp the plug, not the cord.

FANTOM for examination, repair or

or pull cord around sharp edges or

1. Do NOT leave vacuum cleaner

to damage the vacuum cleaner.

when wearing open toe shoes.

electrical shock, or injury:

by or near children.

removing filters.

with wet hands.

attachments.

adjustment.

objects.

only manufacturer’s recommended

Page 4 of the Fantom Vacuum FM718 user manual — PRECAUTIONARY MEASURES
Page 4 · click to enlarge
Page 4

once a month or when suction appears to be reduced. To wash your HEPA

CYCLONIC BAGLESS UPRIGHT

TO ORDER REPLACEMENT FILTERS OR BELTS

Filter Ring, Pre-Motor, Secondary and Exhaust Filters are washable. They

replaced every three (3) to six (6) months, depending on amount of use, to

Dust Cup Filter, hold filter cartridge by frame flange and rinse under a tap

HEPA filter material may occur, this is normal and will not affect the filter's

secondary filter, pre-motor filter or the exhaust filter you allow them to dry

Make sure that ALL washable Filters are completely dry before inserting

performance. When finished, shake off excess water. Do NOT wash in

COMPLETELY before using again. We recommend 24 hours to air dry.

ensure peak performance of your vacuum. We recommend washing it

It is important that when you wash the HEPA dust cup filter, filter ring,

Call1 (800) 275-9251 Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time

until all observable dirt has been removed. Some discoloration of the

should however be replaced every three (3) months to ensure peak

Fantom Vacuum FM718 — CYCLONIC BAGLESS UPRIGHT diagram (page 4)
Fig. 4

The HEPA Dust Cup Filter may be washed. It should, however, be

OR FOR TECHNICAL SUPPORT

visit our websitewww.fantom.com 6. Do not pick up anything that is

for Model FM718

cigarettes, matches or hot ashes. Please Note:

Important:

performance of your vacuum.

DO NOT DRY IN DRYER.

back in the vacuum.

dishwasher.

5. When pulling out the power plug

from the wall outlet, pull the plug

your hands are dry. 7. Do not run appliance over power

Fantom Vacuum FM718 — for Model FM718 diagram (page 4)
Fig. 5 · for Model FM718

make sure to remove large or

burning or smoking such as

8. Do not use without dust cup
9. Before you start vacuuming,
Fantom Vacuum FM718 — for Model FM718 diagram (page 4)
Fig. 6 · for Model FM718

blocked, switch off the vacuum cleaner and remove the blocking

sharp objects that might

Fantom Vacuum FM718 — for Model FM718 diagram (page 4)
Fig. 7 · for Model FM718

filter or filters in place.

damage the vacuum. 4. Keep hair, loose clothing, fingers,

not the power cord.

PRECAUTIONARY MEASURES

cord.

substance before you start the unit again.

Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 8

openings, rotating agitator and other

feet and all parts of body away from

into the wall outlet, make sure that

Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 9
2. Before inserting the power plug
1. Do not operate the vacuum

cleaner to close too heaters,

Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 10
Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 11
3. Do not vacuum any liquids.
Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 12

moving parts.

Fantom Vacuum FM718 — PRECAUTIONARY MEASURES diagram (page 4)
Fig. 13

or radiators.

or

Page 5 of the Fantom Vacuum FM718 user manual — Technical Specifications
Page 5 · click to enlarge
Page 5
Fantom Vacuum FM718 — Technical Specifications diagram (page 5)
Fig. 14 · Technical Specifications
PROBLEMPOSSIBLE CAUSEPOSSIBLE Cleaner Won’t Run1. Not properly plugged into wall outlet. 2. No electricity in wall outlet. 3. On/Off switch not turned on. 4. Motor thermostat tripped. 5. Blown fuse/tripped breaker.1. Plug in firmly. 2. Check fuse or breaker. 3. Push on/off switch to on 4. Reset motor thermostat. (page 8 ) 5. Reset circuit breaker or replace fuse. Cleaner Won't Pick Up1. Full or clogged dust cup. 2. Wrong pile height setting. 3. Clogged nozzle. 4. Clogged dust inlet port. 5. Clogged hose. 6. Broken belt. 7. Hose not inserted fully. 8. Dirty filters. 9. HEPA filter needs cleaning or replacing. 10. HEPA filter frame needs cleaning.1. Clean dust cup. (page 5) 2. Adjust setting. (page 5) 3. Remove obstruction. 4. Remove power head cover and remove obstruction. 5. Remove obstruction. 6. Replace belt. (page 8) 7. Push hose in securely. 8. Clean / change filters. (page 7) 9. Clean or replace HEPA filter. (page 6) 10. Clean HEPA filter frame. (page 6) Cleaner Picks Up Moveable Rugs Or Pushes Too Hard1. Wrong pile height setting.1. Adjust setting. (page 5) Agitator Does Not Turn1. Broken belt. 2. Belt installed incorrectly.1. Replace belt. (page 8) 2. Check belt changing and agitator cleaning. (page 8) Air Flow Restricted With Attachment Use Sound Changes1. Attachment use restricts air flow. 2. New carpet debris clogging air path.1. Check attachment. (page 4) 2. Remove obstruction.
Fantom Vacuum FM718 — Technical Specifications diagram (page 5)
Fig. 15 · Technical Specifications

Technical Specifications

Voltage120V., 60Hz. Power: 12 Amps
Fantom Vacuum FM718 — Technical Specifications diagram (page 5)
Fig. 16 · Technical Specifications
1. Replace belt. (page 8) 2. Check belt changing and agitator cleaning. (page 8)
2. No electricity in wall outlet. 3. On/Off switch not turned on. 4. Motor thermostat tripped. 5. Blown fuse/tripped breaker.
1. Full or clogged dust cup. 2. Wrong pile height setting. 3. Clogged nozzle. 4. Clogged dust inlet port. 5. Clogged hose. 6. Broken belt. 7. Hose not inserted fully. 8. Dirty filters. 9. HEPA filter needs cleaning or replacing.
1. Attachment use restricts air flow.
2. New carpet debris clogging air path.
1. Not properly plugged into wall outlet.
10. HEPA filter frame needs cleaning.

Not Turn 1. Broken belt. 2. Belt installed incorrectly.

convenience.

Show 16 more labels / short text on this page
Cleaner Won’t · Cleaner Won't · Cleaner Picks · Up Moveable · Agitator Does · Pushes Too · Attachment · Use Sound · Pick Up · Rugs Or · Air Flow · Restricted · Changes · Hard · Run · With
Page 6 of the Fantom Vacuum FM718 user manual — Cord Assembly
Page 6 · click to enlarge
Page 6
2. With a flat head screw driver, snap off the lens cover by pressing down on the

two notches on the lens cover. (Fig. 23)

6. Replace the head light lens by pushing it in so that it snaps back in place.

disconnected before removing the dust

1. Turn unit “Off” and unplug from wall outlet.

cup, HEPA filter,changing the filters or

4. Remove the light bulb by pulling it out carefully.
5. Replace the new bulb by pushing it in.

Changing the Headlight Bulb

Fantom Vacuum FM718 — Changing the Headlight Bulb diagram (page 6)
Fig. 17 · Changing the Headlight Bulb

shock, the power cord must be

3. Lift off the head light lens.

OPERATING INSTRUCTIONS

checks.

11 Loop the new belt first over the motor drive shaft and then over the agitator

Fantom Vacuum FM718 — OPERATING INSTRUCTIONS diagram (page 6)
Fig. 18
17. When screwing in the center screw, hold the carpet height adjustment
9. Carefully remove any belt residue that may exist in the belt area before

down into the slot and then do the

13. Check to make sure that the belt is centered on the agitator pulley and
14. Replace the belt cover. 15. Replace the power head cover and turn the unit over carefully.

knob from the outside and screw in

18. Replace the lower plate. 19. Once the lower plate is attached, replace the base plate with the four
6. Remove the belt cover (Fig. 22, #1) 7. Lift the right side of the brush bar first and then lift the left hand side.
12. Insert the right side of the brush bar in first by placing the end cap

firmly to make sure that each end

16. Replace the lower plate, screwing in the four (4) outer screws first.

10.Remove the worn or broken belt from the motor drive shaft.

8. Remove the brush bar from the power head. (Fig. 22, #4)

same with the left side. Press

replacing with a new belt.

that the brush bar turns.

is completely inserted.

(Fig. 22 #2, #3)

the last screw.

(4) screws.

pulley.

1. Place vacuum in its upright position.

to the highest position and set the

attach the extension tubes to the end

setting it on furniture, fringed area rugs or

stop the beater brush from rotating. When

period of time, particularly on thick carpet.

cleaner around the room by the hose as it

could tip over and cause damage. When

multiple types of carpeting, bare floors or

upholstery with attachments. When using

tool, round brush or the upholstery brush,

2. Plug the power cord into the electrical outlet.

Make sure that the vacuum cleaner

the rear of the unit and push in the

hose with the attachments. When using

Selector to the “Floor” position. This will

the attachment tools such as the crevice

Fantom Vacuum FM718 — OPERATING INSTRUCTIONS diagram (page 6)
Fig. 19

is NOT plugged into the electrical

2. Turn the carpet height selector
3. Remove the hose connector from

desired attachment firmly onto the

upholstery brush to the end of the

carpeted stairs while you are using the

extend the hose length when reaching.

Trying to reach beyond the hose reach

place the handle of the vacuum in the

1. Turn the quick release cord holder to either side 180° to release the

outlet when adding or removing

Carpet to Floor selector to the

attachments, set the Carpet to Floor

vacuuming carpets, avoid leaving the

vacuum in one place for an extended

using the attachments, do NOT over

The upright vacuum can be used on

5. When using the attachments, the vacuum must be in the upright
4. If additional length is required,

of the hose and then attach the

could cause the vacuum to tip over.

head and pull the handle back.

crevice tool, round brush or

the unit to vacuum floors or with

Using the Attachments

“Floor” position.

3. Push the On/Off button to the "On"

end of the hose.

extension tube.

the vacuum on.

position. (Fig. 3)

accessories.

4. To release the handle, step

OPERATING INSTRUCTIONS

How to Start

upright position.

power cord.

tightening could strip the screw holes.

Warning: Always make sure that the

Assembling Your Vacuum Cleaner

Fantom Vacuum FM718 — Warning: Always make sure that the diagram (page 6)
Fig. 20 · Warning: Always make sure that the

Caution: Do not over tighten. Over

Fantom Vacuum FM718 — Caution: Do not over tighten. Over diagram (page 6)
Fig. 21 · Caution: Do not over tighten. Over

into an electrical outlet until

2. Lift vacuum body to upright position. 3. Remove the screw (1) that comes attached to the
5. Once handle is in place, secure the handle with the screws (2). (Fig. 1)

Do not operate the vacuum without

Note: Do not plug the power cord

1. Carefully unpack all components, set aside packaging.
1. Make sure that the quick release cord holder is in the upright

to the left or to the right to unwrap

vacuum is turned off

before unplugging.

the handle screws in place.

the vacuum is fully

the power cord. (Fig. 2)

handle into position.

4. Turn the quick release cord holder
4. From the rear of the vacuum, align
2. Remove the wire tie from the power
3. Wrap the cord into place by wrapping

assembled.

Handle Assembly

onto vacuum. If

Cord Assembly

it in a clockwise

holders. (Fig. 2)

position.

body.

cord.

Show 13 more labels / short text on this page
Notches · performing maintenance/trouble shooting · position to turn · on the power · groove and slide · thumb and finger · pressure to slide · direction around · the quick release · the handle with · necessary, use · cord holder and · the lower cord
Page 7 of the Fantom Vacuum FM718 user manual — Motor Thermostat
Page 7 · click to enlarge
Page 7

cup, dust cup filter,changing the filters or

disconnected before removing the dust

The “Dust Cup” must always be emptied

line on the dust cup. To remove the dust

Removing & Emptying Dust Cup

when the dirt level reaches the "FULL"

3. To empty the dust cup, hold it by the handle over a garbage can
1. Press down on the dust cup release button that is located on

release button to empty. (Fig. 8)

Fantom Vacuum FM718 — Removing & Emptying Dust Cup diagram (page 7)
Fig. 22 · Removing & Emptying Dust Cup
2. Holding the dust cup from the handle, pull the dust cup out
Fantom Vacuum FM718 — Removing & Emptying Dust Cup diagram (page 7)
Fig. 23 · Removing & Emptying Dust Cup

shock, the power cord must be

the handle of the dust cup.

and press on the trap door

from the vacuum. (Fig. 7)

cup from the vacuum:

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

Fantom Vacuum FM718 — OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS diagram (page 7)
Fig. 24

(Fig. 6)

checks.

You may need to raise the height of the

Place unit in "HIGH" setting when using

damage. Always set the Carpet to Floor

when vacuuming certain types of carpet

carpet or floor covering manufacturer's

multiple types of carpeting, bare floors

Fantom Vacuum FM718 — OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS diagram (page 7)
Fig. 25

selector to “Floor” setting when using

This upright vacuum can be used on

1. Turn vacuum cleaner "Off". 2. Select a pile height setting by sliding the carpet height selector

such as scatter rugs and longer pile

attachments to prevent possible floor

vacuum to make some jobs easier,

plush scatter rugs, tools

or floor covering. Always check the

HIGHshag carpet, long pile,

or upholstery with attachments.

to the desired setting. (Fig. 4)

carpets. Suggested settings are:

LOWshort to medium pile,

Suggested Pile Height Setting:

MEDmedium to long pile
FLOORvery low pile, bare

To select a pile height setting:

Fantom Vacuum FM718 — OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS diagram (page 7)
Fig. 26
Fantom Vacuum FM718 — OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS diagram (page 7)
Fig. 27

Fig. 21 Fig. 5 8

Cleaning the Dust Cup Cleaning & Changing the Belt Carpet Height Selector

the accessories. (Fig. 5)

before vacuuming.

electric shock, the power cord must

dust cup, HEPA filter,changing the filters

frequency will depend upon the amount

2. Turn the vacuum upside down on a flat level surface.
4. After you have removed the base plate, remove the remaining five (5)

screws from the lower plate using a

5. With the unit still lying down, turn the unit over and lift the power head

be disconnected before removing the

1. Turn the vacuum "Off" and unplug from power supply.

attach the base plate to the lower

cover starting from the back of the

Occasionally the power nozzle drive

3. Using a Philips screw driver, remove the four (4) screws that
Fantom Vacuum FM718 — Cleaning the Dust Cup Cleaning & Changing the Belt Carpet Height Selector diagram (page 7)
Fig. 28 · Cleaning the Dust Cup Cleaning & Changing the Belt C…

Philips screw driver. (Fig. 20)

Fantom Vacuum FM718 — Cleaning the Dust Cup Cleaning & Changing the Belt Carpet Height Selector diagram (page 7)
Fig. 29 · Cleaning the Dust Cup Cleaning & Changing the Belt C…
Fantom Vacuum FM718 — Cleaning the Dust Cup Cleaning & Changing the Belt Carpet Height Selector diagram (page 7)
Fig. 30 · Cleaning the Dust Cup Cleaning & Changing the Belt C…

belt will require changing, the

of use your vacuum sees.

power head. (Fig. 21)

plate. (Fig. 19)

shooting checks.

Fantom Vacuum FM718 — Cleaning the Dust Cup Cleaning & Changing the Belt Carpet Height Selector diagram (page 7)
Fig. 31 · Cleaning the Dust Cup Cleaning & Changing the Belt C…

disconnected before removing the dust

cup, HEPA filter,changing the filters or

automatically turn the unit off. Should

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

  • Check the source of overheating problem. (i.e. clogged hose or
  • If clogged hose or filter is found, unclog the hose and replace the
  • Wait at least 45 minutes before attempting to reuse the vacuum.
  • After unit has cooled down for 45 minutes, plug in the cleaner and push the On/Off button. The
  • If the vacuum still does not start, contact FANTOM customer

dishwasher. Fig. 18

  • Push the On/Off button once.
  • Disconnect the plug from the power source.

service at 1 (800) 275-9251.

shock, the power cord must be

vacuum should start again.

washed in lukewarm water.

detergents. Ensure that the

putting back on the vacuum

dust cup is fully dry before

(Fig. 18) Do not wash in

The dust cup can be

Motor Thermostat

Do not use strong

this occur:

filters.

cleaner.

checks.

Show 12 more labels / short text on this page
performing maintenance/trouble shooting · Trap Door · Release · recommended cleaning instructions · bare floors · floors · or performing maintenance/trouble · Lower · Plate · Base Plate · performing maintenance/trouble shooting · filter)
Page 8 of the Fantom Vacuum FM718 user manual — Cleaning the HEPA Dust Cup Filter
Page 8 · click to enlarge
Page 8

Changing & Cleaning the Exhaust

Motor Filter WarningTo reduce the risk of electric
3. Remove the exhaust filter. 4. Rinse in lukewarm water and let the filter air dry for 24 hours before re-

fresh tepid water. A mild detergent may

disconnected before removing the dust

cup, HEPA filter,changing the filters or

1. Check the exhaust filter frequently and replace with new filters when

use a washing machine to rinse the

filter. Do not use a hair dryer to dry

filter should be thoroughly washed with

front of the unit below where the dust

you must first remove the filter cover.

installing into the vacuum. Do not

5. When the filter is dry, replace into the vacuum and replace the filter

checks. The exhaust filter is located on the

cup is. To remove the exhaust filter,

2. Remove the exhaust filter cover. (Fig. 17)

operate the vacuum without ALL

Fantom Vacuum FM718 — Changing & Cleaning the Exhaust diagram (page 8)
Fig. 32 · Changing & Cleaning the Exhaust

shock, the power cord must be

the filter. Air dry only. Never

Fantom Vacuum FM718 — Changing & Cleaning the Exhaust diagram (page 8)
Fig. 33 · Changing & Cleaning the Exhaust

the filters in place.

be used if required.

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

cover.

dirty.

checks.

Filter Changing & Cleaning the Pre-

Fantom Vacuum FM718 — Filter Changing & Cleaning the Pre- diagram (page 8)
Fig. 34 · Filter Changing & Cleaning the Pre-

disconnected before removing the dust

1. Remove the dust cup. (See instructions on page 5 for removing
4. After air drying for 24 hours, replace in the vacuum.

the secondary filter in place. Fig. 15

cup, HEPA filter,changing the filters or

washable filter and can be cleaned by

rinsing under lukewarm water. Always

24 hours before replacing in the vacuum. Do not use a hair dryer to dry

2. Hold the Pre-Motor filter cover and turn counter-clockwise to unlock

the lug holes and turn clockwise to

The pre-motor filter is located in the

allow the pre-motor filter to air dry for

3. Remove the pre-motor filter and clean by rinsing under lukewarm
5. To replace the pre-motor filter cover, insert the locking lugs into

Cleaning the Secondary Filter

vacuum underneath the dust cup.

it. Air dry only. To remove the pre-

Always allow the secondary

filter to air dry for 24 hours

shock, the power cord must be

Please note that this filter is a

and lift to remove. (Fig. 16)

(Fig. 15) We recommend

washing your HEPA filter.

washing it when you are

before replacing into the

1. Underneath the HEPA filter there is a

This is washable in

vacuum. Never run

secondary filter.

lukewarm water.

the dust cup).

motor filter:

water.

lock.

Fantom Vacuum FM718 — Cleaning the Secondary Filter diagram (page 8)
Fig. 35 · Cleaning the Secondary Filter

HEPA filter will discolor over time - This is

1. Before replacing the HEPA filter in the HEPA Filter frame, you can (should)

just running it under the tap to remove

any dust that is adhering to the frame.

(Fig. 13) Do NOT place in dishwasher.

24 hours before replacing onto the HEPA filter. Never run the vacuum

emptied during prolonged usage or risk

rinse the frame in lukewarm water by

2. Make sure that the filter frame is completely dry before replacing into
Please NoteThe white material in the

before each use and during prolonged

recommend replacing it every three (3)

remove dirt and clean the HEPA dust

Cleaning the HEPA Filter Frame

and clean the HEPA dust cup filter

usage. Never over fill the dust cup -

Fantom Vacuum FM718 — Cleaning the HEPA Filter Frame diagram (page 8)
Fig. 36 · Cleaning the HEPA Filter Frame

NORMAL and will NOT affect the

cup filter each time the dust cup is

without all the filters in place.

the dust cup. Always air dry.

Cleaning the Filter Ring

1. Around the HEPA filter there is a filter ring.

filter. Always allow the

performance of the filter.

2. We recommend washing the filter ring

filter ring to air dry for

This is washable in

(Fig. 14) To remove

the filter ring, slide it

off the HEPA filter.

lukewarm water.

motor damage.

months.

Fantom Vacuum FM718 — Cleaning the Filter Ring diagram (page 8)
Fig. 37 · Cleaning the Filter Ring

your suction power - if not cleaned properly.

Fantom Vacuum FM718 — Cleaning the Filter Ring diagram (page 8)
Fig. 38 · Cleaning the Filter Ring
Fantom Vacuum FM718 — Cleaning the Filter Ring diagram (page 8)
Fig. 39 · Cleaning the Filter Ring

“TapClean” HEPA Dust Cup Filter will stop

times smaller than a human hair!!! Because

of this incredible filtration performance, the

accumulate many fine dust particles inside

Cleaning the HEPA Dust Cup Filter

airborne allergens from re-entering the air

you breathe. In fact, it stops 99.97% of all

the white filter folds that are difficult to see

particles as small as 0.3 microns - many

but which will eventually block or reduce

Clean the HEPA Filter after each use as

1. To remove the HEPA filter, remove the dust cup from the

most of the tiniest dust particles and

HEPA Dust Cup Filter will quickly

2. To remove the dust cup cover, hold the cover by

(Fig. 12) We recommend

or when suction appears

reduced. Always allow 24

hours for air drying before

replacing into the vacuum.

the handle, turn counter

filter from the dust cup.

4. Remove the filter ring that is around the HEPA

dust cup filter on a hard

running it under the tap

to run on the dirty side.

washing it once a month

3. Remove the HEPA Rinseable "Tap Clean"

clockwise and lift the

surface until no more

The HEPA filter may

Fantom Vacuum FM718 — Cleaning the HEPA Dust Cup Filter diagram (page 8)
Fig. 40 · Cleaning the HEPA Dust Cup Filter

described in this section.

falling out. (Fig. 11)

also be washed by

cover off. (Fig. 9)

filter. Vigorously

(Fig. 10)

unit.

Show 15 more labels / short text on this page
performing maintenance/trouble shooting · Pre-Motor · Lug · Holes · Pre-Motor · Filter · Filter · Cover · performing maintenance/trouble shooting · the vacuum without · washing your HEPA · when you are · "TapClean" the HEPA · allowing the water · dust is observed
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Cleaner Won’t Run1. Not properly plugged into wall outlet. 2. No electricity in wall outlet. 3. On/Off switch not turned on. 4. Motor thermostat tripped. 5. Blown fuse/tripped breaker. p.5
Cleaner Won't Pick Up1. Full or clogged dust cup. 2. Wrong pile height setting. 3. Clogged nozzle. 4. Clogged dust inlet port. 5. Clogged hose. 6. Broken belt. 7. Hose not inserted fully. 8. Dirty filters. 9. HEPA filter needs cleaning or replacing. 10. HEPA filter frame needs cleaning. p.5
Cleaner Picks Up Moveable Rugs Or Pushes Too Hard1. Wrong pile height setting. p.5
Agitator Does Not Turn1. Broken belt. 2. Belt installed incorrectly. p.5
Air Flow Restricted With Attachment Use Sound Changes1. Attachment use restricts air flow. 2. New carpet debris clogging air path. p.5

Ask about the Fantom Vacuum FM718

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fantom Vacuum FM718

Be the first to ask — other owners or our team will answer.

Original document

Fantom Vacuum FM718 manual PDF

8 pages·1.1 MB·Vacuum Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…