Instruction/ maintenance manual of the product IPL T PC1 Extron electronic
Go to page of 78
User Guide IPL T PC1 IPL T PC1i IP Link ® IP Link Power Contr ol Interfaces 68-738-10 Rev . B 09 11.
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.
Conventions Used in this Guide Notifications In this user guide, the following are used: WARNING: A warning war ns of things or actions that might cause injury , death, or other severe consequences. CAUTION: A caution indicates a potential hazard to equipment or data.
Contents Using the IPL T PC1 Web Pages ......................... 22 Viewing the System Status ............................ 23 Using the Conguration Pages ...................... 24 Configuring the RS-232 Port and the AC Receptacle .................
IPL T PC1 • Contents vi.
Intr oduction This section provides an overview of the Extr on IPL T PC1 and IPL T PC1i IP Link ® Power Control Interfaces, and describes their featur es featur es.
• Industry standard Ethernet protocols — The PC1 uses standar d Ethernet and TCP/IP communication protocols, including ARP (Addr ess Resolution Pr otocol), DHCP (dynamic host configuration protocol), TCP/IP (T ransmission Control Protocol/Internet Protocol), T elnet, and HTTP (HyperT ext T ransfer Protocol).
Application Diagram The following application diagram shows an example of how devices can be connected to the IPL T PC1 or the IPL T PC1i. 200-240V 50/60Hz 10A MAX POWER OUTPUT 10A MAX LAN COM TX IN S.
Installation and Rear Panel This section describes: • Installation Overview • Rear Panels • Connecting Cables Installation Overview T o install and set up an IPL T PC1 interface: 1. Disconnect power from the PC1 interface and the output device (plasma display , VCR, projector , and so forth).
Rear Panels 12A MAX POWER OUTPUT 12A MAX LAN COM TX IN SG +5V RX INPUT IR MA C ADDRESS 100-120V AC 50/60Hz 1 2 3 5 US LISTED 17T T AU DIO/VIDE O AP AR AT US ® 4 7 6 Figure 2. IPL T PC1 Rear Panel (120 V AC) 10A MAX POWER OUTPUT 10A MAX LAN COM TX IN SG +5V RX INPUT IR MA C ADDRESS 200-240V AC 50/60Hz 1 2 3 6 5 4 7 Figure 3.
e IR port — Connect an IR emitter to pins 3 (S, for signal) and 4 (G, for ground) of this shared captive scr ew connector to enable infrar ed remote contr ol of the output device (see “ Wiring for IR Control ” for instructions on connecting an IR emitter to this port).
5. On the drivers list, locate the model name of your output device. In the row for your device, click on the nn Kb link in the Communication Sheet column. In figure 4, below , the Communication sheet link for a 3M-7340 display has been selected. Figure 4.
Wiring the Local Area Network (LAN) Port Wire the connector as shown in the tables below . • For 10Base-T (10 Mbps) networks, use a Category 3 or better cable. • For 100Base-T (100 Mbps) networks, use a Category 5 cable. • Use a straight-through cable to connect to a switch, hub, or r outer .
Wiring the Contact Input Port The IPL T PC1 contact closure Input port can be connected to any device pr oviding a closur e to ground (closed = logic 1 and open = logic 0). The contact input is connected to 5 VDC via a 1k ohm pull-up resistor and must be wir ed with a gr ound.
Fr ont Panel Featur es and Operation This section contains a description of the IPL T PC1 and IPL T PC1i front panel featur es and instructions for setting up the PC1 using the front panel.
g Reset button (recessed) — Use the tip of a small Phillips scr ewdriver or an Extr on T weeker (provided) to press this r ecessed button to reset the unit in one of five r eset modes (see “ Resetting ,” later in this section, for details on reset modes and on using this Reset button).
Front Panel Security Lockout (Executive Mode) When the PC1 is in front panel lock mode (executive mode), it does not accept commands from the fr ont panel. If any button is pr essed while the unit is in executive mode, the Power LED flashes three times, indicating that the input fr om the fr ont panel is not being accepted.
Mode 1 Activation Hold in the Reset button while applying power to the unit. Result Returns the unit to the default base firmware that was shipped with the PC1 from the factory . Event scripting does not start when the unit is powered on in this mode.
Mode 3 Activation Hold the Reset button in until the Power LED blinks once (approximately 3 seconds). Release it, then immediately pr ess it again momentarily (for less than 1 second). NOTE: Nothing happens if the momentary press does not occur within 1 second.
HTML Configuration and Contr ol This section describes the IPL T PC1 embedded web pages and provides instructions on accessing and using them to configure the PC1.
Setting Up and Configuring the PC1 Using ARP The Address Resolution Pr otocol (ARP) command pr ovides a quick way to set up an IP address for the PC1, using your PC. The ARP commands tell your computer to associate the PC1 Media Access Control (MAC) addr ess with an IP addr ess that you assign.
The response should be the new IP addr ess of the PC1, as shown below . Figure 11. Ping Command on a Command Prompt Scr een 7. After verifying that the IP address change was successful, issue the arp -d command at the DOS prompt to r emove the addr ess from the computer ARP table.
Setting Up the Computer for IP Communication Follow these steps to set up communication between your computer and the PC1 using Windows 2000, W indows XP , or W indows 7. NOTE: The procedur e and illustrations in this section ar e for Windows XP . For other Windows versions, the screens may appear slightly differ ent.
3. On the Local Area Connection Pr operties window , select Internet Protocol (TCP/IP) , then click the Properties button. If Internet Protocol (TCP/IP) is not on the list, you must install it (see the W indows user manual or the Windows online help system for the procedure).
Figure 14. Internet Protocol (TCP/IP) Properties Window for Windows XP c. Click OK to save the changes and exit the network setup. d. Reboot the computer if requir ed for the changes to become ef fective.
3. Select the Configuration tab, then select System Settings from the sidebar menu on the left of the screen. The PC1 System Settings page appears, showing the default IP address.
Using the IPL T PC1 W eb Pages The IPL T PC1 features an embedded web server , which includes factory set web pages. These pages can be replaced with user -designed files, but the default web pages provide many basic features for configuring, and contr olling the PC1 via a web br owser .
Viewing the System Status The System Status web page, accessed by clicking the Status tab, provides information on the current settings. Changes must be made via the Configuration web pages or SIS programming commands (see “ SIS Pr ogramming and Contr ol ”).
The System Status page displays information in the following categories: • System Description: Includes product model, port and r eceptacle description, part number , firmware version, and the curr ent date and time. • IP Settings: Displays the unit name, DHCP status, IP address, gateway addr ess, subnet mask, and the MAC address.
IP settings The following settings are available in the IP Settings section: • Unit Name : The default is the product name followed by the last six digits of the MAC address. Y ou can give the unit a new name (such as LightsOn&Off or BoardroomA-PC1 ) consisting of up to 24 alphanumeric characters including the hyphen ( - ).
• Daylight Savings : Daylight savings time (DST) is a one-hour offset that is observed in some countries. Y ou can select one of the radio buttons to set the PC1 for daylight savings time for the U. S., Europe, or Brazil; or select Off to disable it.
RS-232 port From the dr op-boxes in the port type section, you can select the baud rate, data bits, parity , stop bits, and flow control for the PC1 serial COM port. Click Submit to enter your selections. If you click Cancel before submitting your selections, your entries ar e r eset to the last saved parameters.
Performing a command T o play a command on the connected device: 1. Click on the driver file in the Driver (first) column to display a list of commands within the selected driver . The example below shows part of a driver command list page for a Sony SL V -D360P DVD/VCR combination.
3. In the Re-enter Admin Password field, enter the same password again to confirm it. Figure 22. Passwords Page with Administrator and User Passwor ds Enter ed 4.
Entering e-mail addresses If you have created scheduled events or monitoring tasks thr ough the Global Configurator software, you may have e-mail alerts with a message corr esponding to an event or task (for example, a timer notification indicating that it is time to replace a pr ojector light bulb).
5. Click the Edit button at the end of the first address r ow in which you want to enter a new address or edit the existing one. The Edit button changes to Save (see the illustration above). 6. Enter the e-mail address of the alert r ecipient in the number ed box under Email Address .
Upgrading Firmware The Firmware Upgrade page lets you br owse to locate and upload a new version of firmwar e for your unit. The uploaded file must have the file extension .S19 . NOTE: The PC1 uses the same firmware as the IPL T PC1. However , it does not accept other firmware files, such as the .
2. Click Browse to open a Choose file window . Figure 25. Firmware File Selected on the Choose File Window 3. In the Choose file window , locate the new firmware version file on your computer and double-click it. (Firmware les must have the extension .
Scheduling The Schedule page accessed from the Configuration scr een lets you schedule when power to the receptacle turns on and off. Y ou can also schedule lock mode, specifying when the PC1 front panel will be locked. Clicking the Clear Schedule button at the bottom of the screen deletes all schedules.
Scheduling output receptacle power T o schedule power on and off to the output receptacle: 1. In the Receptacle 1 section, click On or Off to select the power setting that you want to schedule for the week.
Scheduling front panel lockout (executive mode) 1. In the Executive Mode section, click On or Off to select the lock mode setting that you want to schedule.
Scheduling by day of the week Y ou can also select a day of the week and schedule all power and executive mode time settings for that day at one time: 1.
Changing an individual setting Follow this procedur e if you want to change only one setting on the scheduling table, either for powering on or off, or for executive mode. 1. In the Receptacle or Executive Mode scheduling table, click on the time displayed or the “-” symbol in the cell that you want to change, in the desired day column.
Figure 31. File Management Screen with Thr ee Files Uploaded 4. Click Upload File . While the le is uploading, the Upload File button label changes to Uploading... . When the uploading is complete, the uploaded file name appears in the Files column with a time stamp showing GMT time, and the button returns to its original state.
Custom W eb Pages On the IPL T PC1, custom web pages are supported. Y ou can determine the layout and appearance of the pages displayed on your screen. Server side includes (SSIs) enable you to obtain information from the unit and display the information on web pages.
Code example The following figure shows a practical use for both SSIs and query strings. In this example, the HTML source code contains thr ee SSI commands.
URL encoding URL (Universal Resource Locator) encoding is the method of using ASCII hexadecimal characters to display specific characters in a URL. It is used for several reasons. On some operating systems, certain characters are unsafe or not available, and others ar e r eserved by the HTML or URL specification.
Unsafe characters URLs use some characters for “special use” in defining their syntax and these characters should be encoded. For various reasons, these characters may possibly be misunderstood within a URL. The following table lists unsafe characters.
3. At the < to > prompt, enter the IP addr ess of the PC1 unit. (The default IP addr ess is 192.168.254.254. If the address was changed in the setup or configuration pr ocess, use the new address.) T elnet defaults to port 23. Figure 39. Connecting to the IP Address 4.
T roubleshooting T urn on the equipment in the following order: 1. The PC1 power control interface 2. The power receptacles on the PC1 3. The connected output device on the AC receptacle. If the output A V device cannot be powered on, check the following: Power Connections 1.
If a connection was not made, the following response appears: Figure 41. Response to an Unsuccessful Ping Command If you get a response indicating that the ping was unsuccessful: a. Make sure your unit is using the appr opriate subnet mask (check with your system administrator).
SIS Pr ogramming and Contr ol This section provides instructions on using the Extr on Simple Instruction Set (SIS) commands, which you can use to set up and control the IPL T PC1 fr om a host computer or other contr ol system attached to the rear panel LAN port.
Password Information The ] Password: prompt is displayed only if ther e is a passwor d defined in the unit. It requir es a passwor d (administrator level or user level) followed by a carriage return. The prompt is r epeated if the corr ect password is not enter ed.
Using the Command and Response T able The PC1 can be controlled via either a T elnet (port 23) connection or a web browser (port 80) connection. The ASCII commands listed in the tables perform the same functions, but they are encoded dif fer ently to accommodate the requir ements of each port (T elnet or web browser).
Symbol Definitions ] = CR/LF (carriage return + line feed) (hex 0D 0A ) } = Soft carriage return (no line feed, hex 0D ) (For web browser commands, use the | [pipe] character instead of the soft r eturn.
X1& = Time in tens of milliseconds to wait for the first character to arrive at a serial port before terminating (default= 1 =10 ms; max = 32767 ) the connection X1* = Har dware (MAC) addr ess ( xx-xx-xx-xx-xx-xx ). X1( = Subnet mask ( nnn.nnn.nnn.
X3% = Event number: range = 0 - 99 X3^ = Event buffer 0 = receive 1 = user (absolute) 2 = User (relative) 3 = NVRAM X3& = Memory location: range = 0 through maximum buffer size X3* = Event data size b = bit B = byte (8 bits) S = short (16 bits) L = long (32 bits) NOTE: This parameter is case sensitive.
X5( = IR Playback mode 0 = play once 1 = play continuously Response is returned with leading zeros. T o stop mode 1 playback, send the IR command again with mode 0 selected. X6$ = Time in seconds to keep sending the broadcast message ( 0 - 255 , default = 10 ) X6( = (Ethernet only) Number of seconds before timeout on IP connections (min.
Command and Response T able for SIS Commands Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Power Receptacle Control / Curr ent Sense T ur .
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Information requests (continued) Query bootstrap version 2Q 2Q X1! ] With tagged response .
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Information requests (continued) Request system memory usage 3I 3I Number of bytes used out .
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) IP Setup Commands (continued) Set GMT offset 24 E X# CZ } W X# CZ | Ipz X# ] View GMT offset.
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Password and Security Settings Set administrator password 24 E X3# CA } W X3# CA | Ipa • X4! ] Clear administrator password 24 NOTE: A user passwor d cannot be assigned if an administrator password does not exist.
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Directory Commands Change or create a dir ectory E path / directory /CJ } W path / directory /CJ | Dir • path /d irectory / ] NOTE: A dir ectory does not truly exist until a file has been copied into the path.
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) File Commands (continued) List files from curr ent directory and below E LF } W LF | (See below .
Command ASCII (T elnet) (Host to Switcher) URL Encoded (web) (Host to Switcher) Response (Switcher to Host) Event Control (continued) Write string to event buf fer memory 24,27 E string * X3% , X3^ , .
Refer ence Material Specifications AC control interface Connectors IPL T PC1 ................................. 1 female USA/Edison power connector IPL T PC1i ................................ 1 female IEC power connector V oltage IPL T PC1 ............
IR control interface IR control port ................................ (1) 3.5 mm captive screw connector , 4 pole (shared with contact closure input port) Pin configuration ............................ 3 = S (IR signal output), 4 = GND IR output carrier frequency .
Part Numbers and Accessories Included Parts These items are included in each or der for an IPL T PC1 or IPL T PC1i interface: Included Parts Part Number IPL T PC1 60-544-10 IPL T PC1i 60-544-20 Rubber feet (self-adhesive) (4) 2-pin female captive screw terminal (2) 4-pin female captive screw terminal (1) 18 A WG IEC power cord (U.
• Reduced air flow — Install the equipment in the rack so that the amount of air flow requir ed for safe operation of the equipment is not compr omised. • Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazar dous condition.
5. Slide the unit slightly forward or back, then tighten all four scr ews to secur e it in place. Figure 44. Mounting the IPL T PC1 Under Furniture IPL T PC1 • SIS Programming and Contr ol 66.
Glossary Numbers and A 10/100Base-T Ethernet that uses unshielded twisted pair (UTP - Cat 5, and so forth) cable, in which the amount of data transmitted between two points in a given amount of time i.
DHCP ( Dynamic Host Configuration Protocol ) is a standar dized communications protocol that enables network administrators to locally and automatically manage the assignment of IP addresses in an organization’ s network. Driver This is a Global Configurator (GC) compatible package.
GlobalViewer (GV) A set of web pages (HTML, XML, JS) and graphics that are loaded into the memory of an IPL T PC1 interface. These pages provide an interface for contr ol of devices attached to the IPL T PC1 interface. They communicate with the event scripts running on the device, and the event scripts issue the commands and queries.
S SIS ( Simple Instruction Set ) A set of commands developed by Extron that allow contr ol of the PC1 via the keyboard of a PC with an Ethernet connection.
URL encoding URL encoding allows you to send information and commands to the unit to change its configuration or provide you with feedback. Web Server Resides on the IPL T PC1 interface and provides storage of the default web pages, GlobalViewer , and your custom web pages.
Extr on W arranty Extron Electr onics warrants this pr oduct against defects in materials and workmanship for a period of three years fr om the date of purchase.
An important point after buying a device Extron electronic IPL T PC1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Extron electronic IPL T PC1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Extron electronic IPL T PC1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Extron electronic IPL T PC1 you will learn all the available features of the product, as well as information on its operation. The information that you get Extron electronic IPL T PC1 will certainly help you make a decision on the purchase.
If you already are a holder of Extron electronic IPL T PC1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Extron electronic IPL T PC1.
However, one of the most important roles played by the user manual is to help in solving problems with Extron electronic IPL T PC1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Extron electronic IPL T PC1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center