INSTALLATION & OPERATION MANUAL VENTED MODELS: 26-GBVLP 26-GBVNG 60-SHBVLP 60-SHBVNG 60-TRBVLP 60-TRBVNG NOTE: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER. CONTACT CU STOMER SERVICE @ 1-800-245 -648 9. Save These Instructions Questions? Need Parts or Options? www.
A letter from our Technical Support department : Thank you for purchasing this fine produ ct from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store.
SAFETY PRECAUTIONS THIS VENTED GAS FIREPLACE HEATER MUST BE INSTALLED, REPAIRED AND INSPECTED ANNUALLY BY QUALIFIED SERVICE PERSONNEL. I T IS ALSO RECOMMENDED T HAT IT BE INSPECTED BEFORE USE. MORE FREQUENT CL EANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING AND BEDDING TYPE MATERIAL.
LISTING AND CODE APPROVALS THIS VENTED GAS FIREPLACE HEATER HAS BEEN TESTED FOR COMPLIANCE WITH THE ANSI STANDARD Z21.88-2002 A ND THE CANADIAN CSA 2.33-M02 ST ANDARDS. THIS UNIT IS LISTED WITH INTERTEK TESTING SERVICES (WARNOCK HE RSEY, INC.) OF MIDDLET ON, WISCONSIN.
Type B-1 Vent Pipe is designed for insta llation within a building -- it is not intend ed for outside use unless it is encl osed in a protective structure and i nsulated. The re quirement for this i s clearly stated in the Venting Tables, Category 1 – Centra l Furnaces, AGA and GAMA “current edition” for U.
Next, find the vent safety shut-off switch inside the draft hood on the back of the stove . It is the small disc-shaped obje ct screwed to an L-shap ed bracket; there are two (2) sets of holes on this bracket. Position the vent safety shut-off switch so the switch is as far down in th e flue as possible, or in a position close s t to the floor .
B. Floor Protection This stove may be installed on a hard combustible surface such as a wood floor, and it may also be installed on non- combustible surfaces such as brick, marble or slate. Floor protection will be required if this unit is placed on a combustible ma terial other than wood.
SECTION V: BLOWER The blower is standard on your vente d gas fireplace heater and p rovides 100 CFM of circulating air capability – it opera tes on 115 volts AC, 60 HZ power source and draws 1.5 AMPS. The blower is attached to the rear of the stove with four (4) screws.
LIGHTING INSTRUCTIONS 1. STOP! Read “For Your Safety” above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. T his appliance is equipped wit h a manual piezoelectric ignition devic e. Do not attempt to light the pilot by hand.
Blower Wiring Valve/Thermostat Wiring SECTION VII: FIRST FIRE HINTS YOU SHOULD KNOW A. Lighting the Pilot Some additional pointers or guidelines about light ing the pilot may be helpful. First time ignition should be done by a qualified service person.
C. Glass Windows This unit is manufactured with high temperature cerami c glass, an d substitute materials should not be used. This stove should not be operated if t he glass is cra cked, broken or removed. The glass/frame assembly shall be replaced as a complete unit as supplied by the manufacturer.
Move the thermostat switch to the “OFF” position. Pl ease note while the thermostat is in this position the pilot light still remains on, but the unit will not light.
Trouble Shooting Guide Warning: To avoid electrical shock, always disconnect the u nit before attempting any trouble shooting procedures (unless otherwise indicated in this manual). If the solution in this guide does not correct the problem, cons ult y our local dealer or call the factory.
Installation Drawings – Through-t he-Ceiling and Through-the-Wall Note: When runnin g double-walled pipe up the side of ho m e, you must build a chase around the chimney pip e.
Have this information o n hand if you telephon e the factory or your dealer regarding this pro duct. (Retain for your files) Model Number ____________ ______________________ Date of Purchase _________.
.
WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) __ ________________________________ ____________ Address ___________ ______________ ____ ____________________________ City _______.
An important point after buying a device England's Stove Works 60-TRBVNG (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought England's Stove Works 60-TRBVNG yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data England's Stove Works 60-TRBVNG - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, England's Stove Works 60-TRBVNG you will learn all the available features of the product, as well as information on its operation. The information that you get England's Stove Works 60-TRBVNG will certainly help you make a decision on the purchase.
If you already are a holder of England's Stove Works 60-TRBVNG, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime England's Stove Works 60-TRBVNG.
However, one of the most important roles played by the user manual is to help in solving problems with England's Stove Works 60-TRBVNG. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device England's Stove Works 60-TRBVNG along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center